Hoshizaki America, Inc.
|
|
|
- Jesse Patrick
- 9 years ago
- Views:
Transcription
1 Hoshizaki America, Inc. Modular Flaker Models F-801MAH(-C) F-801MWH(-C) A Superior Degree of Reliability SERVICE MANUAL Number: Issued: Revised:
2 IMPORTANT Only qualified service technicians should attempt to service or maintain this icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service Manual. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker. Should the reader have any questions or concerns which have not been satisfactorily addressed, please call or write to the HOSHIZAKI Technical Support Department for assistance. HOSHIZAKI AMERICA, INC. 618 Highway 74 South Peachtree City, GA Attn: HOSHIZAKI Technical Support Department Phone: Technical Service (770) Fax: (770) Web Site: Note: To expedite assistance, all correspondence/communication MUST include the following information: Model Number Serial Number Complete and detailed explanation of the problem 2
3 Please review this manual. It should be read carefully before the icemaker is serviced or maintenance operations are performed. Only qualified service technicians should service and maintain the icemaker. This manual should be made available to the technician prior to service or maintenance. CTENTS I. Specification Icemaker... 5 F-801MAH... 5 F-801MWH... 6 F-801MAH-C... 7 F-801MWH-C... 8 II. General Information Construction... 9 F-801MAH/-C... 9 F-801MWH/-C Control Box Layout F-801MAH/-C F-801MWH/-C III. Technical Information Water Circuit and Refrigeration Circuit F-801MAH/-C F-801MWH/-C Wiring Diagrams F-801MAH/-C, F-801MWH/-C Sequence of Electrical Circuit Timing Chart Performance Data F-801MAH F-801MWH F-801MAH-C F-801MWH-C IV. Adjustment of Components Adjustment of Water Regulating Valve (water-cooled model only) Adjustment of Flake Size V. Service Diagnosis No Ice Production Low Ice Production Other VI. Removal and Replacement of Components Service for Refrigerant Lines [a] Refrigerant Recovery [b] Evacuation and Recharge [R-404A] Brazing Removal and Replacement of Compressor Removal and Replacement of Drier
4 5. Removal and Replacement of Expansion Valve Removal and Replacement of Water Regulating Valve (water-cooled model only) Removal and Replacement of Evaporator Assembly Removal and Replacement of Fan Motor Removal and Replacement of Control Water Valve Removal and Replacement of Flush Water Valve VII. Cleaning and Maintenance Preparing the Icemaker for Long Storage Cleaning and Sanitizing Instructions [a] Cleaning Solution [b] Cleaning Procedure [c] Sanitizing Solution [d] Sanitizing Procedure - Initial [e] Sanitizing Procedure - Final Maintenance
5 I. Specification 1. Icemaker F-801MAH AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V 9.4 RLA 51 LRA GEAR MOTOR 120 V 3 FLA 1/4 HP FAN MOTOR 115 V 0.85 FLA 1/15 HP OTHER 120 V 0.03 A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA LY) 20 A MAX. CIRC. BREAKER (CANADA LY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTI Ambient WATER TEMP. ( F) PER 24 HR. Temp.( F) lbs./day ( kg/day ) 70 * 823 (373) 786 (357) 748 (339) Reference without *marks (323) 677 (307) 644 (292) (278) * 599 (272) 555 (252) (239) 502 (228) * 471 (214) SHAPE OF ICE Flake ICE QUALITY Approx. 70%, Ice (90/70 F, Conductivity 200 µs/cm) APPROXIMATE STORAGE CAPACITY N/A ELECTRIC & WATER CSUMPTI 90/70 F 70/50 F ELECTRIC W (kwh/100 lbs.) 1131 (4.5) 1089 (3.2) POTABLE WATER 72 (12) 99 (12) gal./24hr (gal./100 lbs.) EXTERIOR DIMENSIS (WxDxH) 22" x 27-3/8" x 25-15/16" (560 x 695 x 658mm) EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear) WEIGHT Net 176 lbs. ( 80 kg ), Shipping 207 lbs. ( 94 kg ) CNECTIS - ELECTRIC Permanent - Connection - WATER SUPPLY Inlet 1/2" FPT - DRAIN Outlet 3/4" FPT ICE MAKING SYSTEM Auger type HARVESTING SYSTEM Direct Driven Auger ( 1/4HP Gear Motor ) ICE MAKING WATER CTROL Float Switch COOLING WATER CTROL N/A BIN CTROL SYSTEM Mechanical Bin Control ( Proximity Sw. ) COMPRESSOR Hermetic, Model RS43-C2E-CAA CDENSER Air-cooled, Fin and Tube Type EVAPORATOR Copper Tube on Cylinder REFRIGERANT CTROL Thermostatic Expansion Valve REFRIGERANT CHARGE R-404A, 1lb 12oz (800 g) DESIGN PRESSURE High 427 PSIG, Low 230 PSIG PC BOARD CIRCUIT PROTECTI High Voltage Cut-off Relay COMPRESSOR PROTECTI Auto-reset Overload Protector GEAR MOTOR PROTECTI Fuse (3A) REFRIGERANT CIRCUIT PROTECTI Auto-reset High Pressure Control Switch LOW WATER PROTECTI Float Switch and Timer ACCESSORIES - SUPPLIED Spare Fuse - REQUIRED Ice Storage Bin OPERATING CDITIS VOLTAGE RANGE V AMBIENT TEMP F WATER SUPPLY TEMP F WATER SUPPLY PRESSURE PSIG We reserve the right to make changes in specifications and design without prior notice. 5
6 F-801MWH AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V 8.5 RLA 51 LRA GEAR MOTOR 120 V 3 FLA 1/4 HP OTHER 120 V 0.03 A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA LY) 20 A MAX. CIRC. BREAKER (CANADA LY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTI Ambient WATER TEMP. ( F) PER 24 HR. Temp.( F) lbs./day ( kg/day ) 70 * 720 (327) 693 (315) 677 (307) Reference without *marks (300) 646 (293) 630 (286) (279) * 605 (274) 587 (266) (260) 560 (254) * 520 (236) SHAPE OF ICE Flake ICE QUALITY Approx. 70%, Ice (90/70 F, Conductivity 200 µs/cm) APPROXIMATE STORAGE CAPACITY N/A ELECTRIC & WATER CSUMPTI 90/70 F 70/50 F ELECTRIC W (kwh/100 lbs.) 1078 (4.3) 1076 (3.6) POTABLE WATER 72 (12) 86 (12) WATER-COOLED CDENSER 360 (60) 219 (31) gal./24hr (gal./100 lbs.) EXTERIOR DIMENSIS (WxDxH) 22" x 27-3/8" x 25-15/16" (560 x 695 x 658mm) EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear) WEIGHT Net 176 lbs. ( 80 kg ), Shipping 207 lbs. ( 94 kg ) CNECTIS - ELECTRIC Permanent - Connection - WATER SUPPLY Inlet 1/2" FPT Cond. Inlet 1/2" FPT - DRAIN Outlet 3/4" FPT Cond. Outlet 3/8" FPT ICE MAKING SYSTEM Auger type HARVESTING SYSTEM Direct Driven Auger ( 1/4HP Gear Motor ) ICE MAKING WATER CTROL Float Switch COOLING WATER CTROL N/A BIN CTROL SYSTEM Mechanical Bin Control ( Proximity Sw. ) COMPRESSOR Hermetic, Model RS43-C2E-CAA CDENSER Water-cooled, tube in tube type EVAPORATOR Copper Tube on Cylinder REFRIGERANT CTROL Thermostatic Expansion Valve REFRIGERANT CHARGE R-404A, 1lb 1oz (470 g) DESIGN PRESSURE High 427 PSIG, Low 230 PSIG PC BOARD CIRCUIT PROTECTI High Voltage Cut-off Relay COMPRESSOR PROTECTI Auto-reset Overload Protector GEAR MOTOR PROTECTI Fuse (3A) REFRIGERANT CIRCUIT PROTECTI Auto-reset High Pressure Control Switch LOW WATER PROTECTI Float Switch and Timer ACCESSORIES - SUPPLIED Spare Fuse - REQUIRED Ice Storage Bin OPERATING CDITIS VOLTAGE RANGE V AMBIENT TEMP F WATER SUPPLY TEMP F WATER SUPPLY PRESSURE PSIG We reserve the right to make changes in specifications and design without prior notice. 6
7 F-801MAH-C AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V 9.4 RLA 51 LRA GEAR MOTOR 120 V 3 FLA 1/4 HP FAN MOTOR 115 V 0.85 FLA 1/15 HP OTHER 120 V 0.03 A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA LY) 20 A MAX. CIRC. BREAKER (CANADA LY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTI Ambient WATER TEMP. ( F) PER 24 HR. Temp.( F) lbs./day ( kg/day ) 70 * 752 (341) 728 (330) 688 (312) Reference without *marks (295) 614 (279) 580 (263) (249) * 552 (250) 490 (222) (210) 437 (198) * 405 (184) SHAPE OF ICE Cubelet ICE QUALITY Approx. 80%, Ice (90/70 F, Conductivity 200 µs/cm) APPROXIMATE STORAGE CAPACITY N/A ELECTRIC & WATER CSUMPTI 90/70 F 70/50 F ELECTRIC W (kwh/100 lbs.) 1169 (5.1) 1110 (3.5) POTABLE WATER 66 (12) 90 (12) gal./24hr (gal./100 lbs.) EXTERIOR DIMENSIS (WxDxH) 22" x 27-3/8" x 25-15/16" (560 x 695 x 658mm) EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear) WEIGHT Net 176 lbs. ( 80 kg ), Shipping 207 lbs. ( 94 kg ) CNECTIS - ELECTRIC Permanent - Connection - WATER SUPPLY Inlet 1/2" FPT - DRAIN Outlet 3/4" FPT ICE MAKING SYSTEM Auger type HARVESTING SYSTEM Direct Driven Auger ( 1/4HP Gear Motor ) ICE MAKING WATER CTROL Float Switch COOLING WATER CTROL N/A BIN CTROL SYSTEM Mechanical Bin Control ( Proximity Sw. ) COMPRESSOR Hermetic, Model RS43-C2E-CAA CDENSER Air-cooled, Fin and Tube Type EVAPORATOR Copper Tube on Cylinder REFRIGERANT CTROL Thermostatic Expansion Valve REFRIGERANT CHARGE R-404A, 1lb 12oz (800 g) DESIGN PRESSURE High 427 PSIG, Low 230 PSIG PC BOARD CIRCUIT PROTECTI High Voltage Cut-off Relay COMPRESSOR PROTECTI Auto-reset Overload Protector GEAR MOTOR PROTECTI Fuse (3A) REFRIGERANT CIRCUIT PROTECTI Auto-reset High Pressure Control Switch LOW WATER PROTECTI Float Switch and Timer ACCESSORIES - SUPPLIED Spare Fuse - REQUIRED Ice Storage Bin OPERATING CDITIS VOLTAGE RANGE V AMBIENT TEMP F WATER SUPPLY TEMP F WATER SUPPLY PRESSURE PSIG We reserve the right to make changes in specifications and design without prior notice. 7
8 F-801MWH-C AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V 8.5 RLA 51 LRA GEAR MOTOR 120 V 3 FLA 1/4 HP OTHER 120 V 0.03 A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA LY) 20 A MAX. CIRC. BREAKER (CANADA LY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTI Ambient WATER TEMP. ( F) PER 24 HR. Temp.( F) lbs./day ( kg/day ) 70 * 645 (293) 620 (281) 608 (276) Reference without *marks (270) 585 (265) 574 (260) (255) * 550 (249) 541 (246) (241) 521 (236) * 485 (220) SHAPE OF ICE Cubelet ICE QUALITY Approx. 80%, Ice (90/70 F, Conductivity 200 µs/cm) APPROXIMATE STORAGE CAPACITY N/A ELECTRIC & WATER CSUMPTI 90/70 F 70/50 F ELECTRIC W (kwh/100 lbs.) 1075 (4.7) 1083 (4.1) POTABLE WATER 66 (12) 77 (12) WATER-COOLED CDENSER 302 (55) 199 (31) gal./24hr (gal./100 lbs.) EXTERIOR DIMENSIS (WxDxH) 22" x 27-3/8" x 25-15/16" (560 x 695 x 658mm) EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear) WEIGHT Net 176 lbs. ( 80 kg ), Shipping 207 lbs. ( 94 kg ) CNECTIS - ELECTRIC Permanent - Connection - WATER SUPPLY Inlet 1/2" FPT Cond. Inlet 1/2" FPT - DRAIN Outlet 3/4" FPT Cond. Outlet 3/8" FPT ICE MAKING SYSTEM Auger type HARVESTING SYSTEM Direct Driven Auger ( 1/4HP Gear Motor ) ICE MAKING WATER CTROL Float Switch COOLING WATER CTROL N/A BIN CTROL SYSTEM Mechanical Bin Control ( Proximity Sw. ) COMPRESSOR Hermetic, Model RS43-C2E-CAA CDENSER Water-cooled, tube in tube type EVAPORATOR Copper Tube on Cylinder REFRIGERANT CTROL Thermostatic Expansion Valve REFRIGERANT CHARGE R-404A, 1lb 1oz (470 g) DESIGN PRESSURE High 427 PSIG, Low 230 PSIG PC BOARD CIRCUIT PROTECTI High Voltage Cut-off Relay COMPRESSOR PROTECTI Auto-reset Overload Protector GEAR MOTOR PROTECTI Fuse (3A) REFRIGERANT CIRCUIT PROTECTI Auto-reset High Pressure Control Switch LOW WATER PROTECTI Float Switch and Timer ACCESSORIES - SUPPLIED Spare Fuse - REQUIRED Ice Storage Bin OPERATING CDITIS VOLTAGE RANGE V AMBIENT TEMP F WATER SUPPLY TEMP F WATER SUPPLY PRESSURE PSIG We reserve the right to make changes in specifications and design without prior notice. 8
9 II. General Information 1. Construction F-801MAH/-C Control Water Valve Water Supply Inlet Bin Control Junction Box Ice Chute Condenser Evaporator Fan Motor Expansion Valve Flush Water Valve Control Box Compressor Drier Gear Motor 9
10 F-801MWH/-C Control Water Valve Water Supply Inlet Bin Control Junction Box Ice Chute Evaporator Water Regulator Expansion Valve Flush Water Valve Control Box Compressor Drier Gear Motor 10
11 2. Control Box Layout F-801MAH/-C WATER CTROL RELAY FLUSH TIMER TRANSFORMER PRESSURE SWITCH CNECTOR GEAR MOTOR RELAY CIRCUIT PROTECT RELAY GEAR MOTOR PROTECT RELAY FAN MOTOR CAP STARTER GEAR MOTOR CAP. FLUSH FLUSH SWITCH ICE POWER SWITCH FUSE START CAPACITOR RUN CAPACITOR CTROL TIMER FUSE (GEAR MOTOR) Note: The above component names are identical with the wiring label, but not with the parts list. 11
12 F-801MWH/-C FLUSH TIMER WATER CTROL RELAY TRANSFORMER PRESSURE SWITCH CNECTOR CIRCUIT PROTECT RELAY GEAR MOTOR RELAY GEAR MOTOR PROTECT RELAY STARTER GEAR MOTOR CAP. FLUSH FLUSH SWITCH ICE POWER SWITCH FUSE START CAPACITOR RUN CAPACITOR CTROL TIMER FUSE (GEAR MOTOR) 12
13 III. Technical Information 1. Water Circuit and Refrigeration Circuit F-801MAH/-C 13
14 F-801MWH/-C 14
15 2. Wiring Diagrams F-801MAH/-C, F-801MWH/-C 15
16 3. Sequence of Electrical Circuit [a] When power switch is moved to position and flush switch to ICE position, water starts to be supplied to reservoir. 16
17 [b] When reservoir has been filled, gear motor starts immediately. 17
18 [c] Compressor starts about 60 sec. after gear motor starts. 18
19 [d] Bin control operates, and about 6 sec. later, compressor and gear motor stop simultaneously. 19
20 [e] Low water (except water-cooled model). 20
21 [f] Low water (water-cooled model), or dirty air filter (air-cooled model), pressure switch to OPEN, compressor and gear motor operate intermittently. 21
22 [g] When flush switch is moved to FLUSH position, flush water valve opens and flushes reservoir and evaporator. 22
23 [h] When flush timer operates (for 15 min. every 12 hours). 23
24 [i] When V are supplied to circuit protect relay, it protects the circuit from miswiring. If the power supply is properly connected, the contact of circuit protect relay does not move even when the coil is energized. 24
25 [j] When input voltage is too low, (less than 70%), gear motor fuse (1.5A) is blown causing the compressor and gear motor to turn off immediately. 25
26 4. Timing Chart 1. CIRCUIT PROTECT RELAY Miswiring. Circuit Protect Relay operates.) Proper wiring. The unit starts. BIN CTROL 2. WATER LEVEL UPPER LOWER BOTTOM 3. FLOAT SWITCH UPPER LOWER 4. WATER CTROL RELAY 5. CTROL WATER VALVE 6. FLUSH TIMER FLUSH SWITCH FLUSH ICE 8. FLUSH WATER VALVE 9. BIN CTROL 10. GEAR MOTOR 1 sec 6 sec 1 sec RELAY 11. GEAR MOTOR 12. FAN MOTOR 13. COMPRESSOR 60 sec 60 sec 14. PRESSURE SWITCH 26
27 LOW WATER FLUSH TIMER 1. CIRCUIT PROTECT RELAY 2. WATER LEVEL UPPER LOWER BOTTOM 3. FLOAT SWITCH UPPER LOWER 4. WATER CTROL RELAY 5. CTROL WATER VALVE 6. FLUSH TIMER min every 12 hr 7. FLUSH SWITCH FLUSH ICE 8. FLUSH WATER VALVE 9. BIN CTROL 10. GEAR MOTOR 150 sec 1 sec 150 sec 1 sec RELAY 11. GEAR MOTOR 12. FAN MOTOR 13. COMPRESSOR 90 sec 60 sec 90 sec 60 sec 14. PRESSURE SWITCH 27
28 FLUSH SWITCH PRESSURE SWITCH FLUSH ICE 1. CIRCUIT PROTECT RELAY 2. WATER LEVEL UPPER LOWER BOTTOM 3. FLOAT SWITCH UPPER LOWER 4. WATER CTROL RELAY 5. CTROL WATER VALVE 6. FLUSH TIMER FLUSH SWITCH FLUSH ICE 8. FLUSH WATER VALVE 9. BIN CTROL 150 sec 1 sec 1 sec 10. GEAR MOTOR RELAY 11. GEAR MOTOR 12. FAN MOTOR 90 sec 60 sec 60 sec 13. COMPRESSOR 14. PRESSURE SWITCH 1 sec 28
29 5. Performance Data F-801MAH APPROXIMATE Ambient Water Temp. (F) ICE PRODUCTI Temp. (F) PER 24 HR. 70 * 823 (373) 786 (357) 748 (339) (323) 677 (307) 644 (292) (278) * 599 (272) 555 (252) lbs./day ( kg/day) (239) 502 (228) * 471 (214) APPROXIMATE ELECTRIC 70 * CSUMPTI * watts * APPROXIMATE WATER 70 * 99 (374) 94 (357) 90 (340) CSUMPTI PER 24 HR (323) 81 (308) 77 (293) (TOTAL) (278) * 72 (272) 67 (252) gal. / day (l/day) (240) 60 (228) * 57 (214) EVAPORATOR OUTLET TEMP. 70 * 15 (-10) 16 (-9) 16 (-9) F ( C) (-9) 16 (-9) 17 (-8) (-8) * 17 (-8) 18 (-8) (-7) 19 (-7) * 20 (-7) HEAD PRESSURE 70 * 204 (14.3) 266 (18.7) 302 (21.2) (14.3) 266 (18.7) 302 (21.2) (14.3) * 266 (18.7) 302 (21.2) PSIG (kg/cm 2 G) (14.3) 266 (18.7) * 302 (21.2) SUCTI PRESSURE 70 * 38 (2.7) 42 (3.0) 46 (3.3) PSIG (kg/cm 2 G) (2.7) 42 (3.0) 46 (3.3) (2.7) * 42 (3.0) 46 (3.3) (2.7) 42 (3.0) * 46 (3.3) TOTAL HEAT OF REJECTI 6398 BTU/h (AT 90 F / WT 70 F) Note: The data without *marks should be used for reference. We reserve the right to make changes in specifications and design without prior notice. 29
30 F-801MWH APPROXIMATE Ambient Water Temp. (F) ICE PRODUCTI Temp. (F) PER 24 HR. 70 * 720 (327) 693 (315) 677 (307) (300) 646 (293) 630 (286) (279) * 605 (274) 587 (266) lbs./day ( kg/day) (260) 560 (254) * 520 (236) APPROXIMATE ELECTRIC 70 * CSUMPTI * watts * APPROXIMATE WATER 70 * 306 (1158) 397 (1504) 631 (2387) CSUMPTI PER 24 HR (1205) 415 (1571) 666 (2520) (TOTAL) (1251) * 433 (1638) 704 (2666) gal. / day (l/day) (1304) 457 (1728) * 778 (2944) EVAPORATOR OUTLET TEMP. 70 * 17 (-8) 17 (-8) 18 (-8) F ( C) (-7) 19 (-7) 20 (-7) (-7) * 20 (-7) 20 (-7) (-7) 20 (-7) * 21 (-6) HEAD PRESSURE 70 * 265 (18.6) 265 (18.6) 266 (18.7) (18.6) 265 (18.6) 266 (18.7) (18.6) * 265 (18.6) 266 (18.7) PSIG (kg/cm 2 G) (18.6) 265 (18.6) * 266 (18.7) SUCTI PRESSURE 70 * 42 (3.0) 43 (3.0) 44 (3.1) PSIG (kg/cm 2 G) (3.0) 43 (3.0) 44 (3.1) (3.0) * 43 (3.0) 44 (3.1) (3.0) 43 (3.0) * 44 (3.1) WATER FLOW FOR CDENSER 15 gal/h (AT 90 F / WT 70 F) PRESSURE DROP OF COOLING WATER LINE Less than 7 PSIG HEAT OF REJECTI FROM CDENSER 5155 BTU/h (AT 90 F / WT 70 F) HEAT OF REJECTI FROM COMPRESSOR 1050 BTU/h (AT 90 F / WT 70 F) Note: The data without *marks should be used for reference. We reserve the right to make changes in specifications and design without prior notice. 30
31 F-801MAH-C APPROXIMATE Ambient Water Temp. (F) ICE PRODUCTI Temp. (F) PER 24 HR. 70 * 752 (341) 728 (330) 688 (312) (295) 614 (279) 580 (263) (249) * 552 (250) 490 (222) lbs./day (kg/day) (210) 437 (198) * 405 (184) APPROXIMATE ELECTRIC 70 * CSUMPTI * watts * APPROXIMATE WATER 70 * 90 (342) 87 (331) 83 (313) CSUMPTI PER 24 HR (295) 74 (279) 70 (264) (TOTAL) (249) * 66 (251) 59 (222) gal. / day (l/day) (210) 52 (199) * 49 (184) EVAPORATOR OUTLET TEMP. 70 * 14 (-10) 14 (-10) 14 (-10) F ( C) (-10) 14 (-10) 14 (-10) (-10) * 14 (-10) 16 (-9) (-9) 18 (-8) * 18 (-8) HEAD PRESSURE 70 * 200 (14.0) 212 (14.9) 219 (15.4) (15.9) 233 (16.4) 241 (16.9) (17.5) * 265 (18.6) 265 (18.6) PSIG (kg/cm 2 G) (19.2) 282 (19.8) * 296 (20.8) SUCTI PRESSURE 70 * 38 (2.7) 41 (2.9) 42 (2.9) PSIG (kg/cm 2 G) (2.9) 42 (3.0) 42 (3.0) (3.0) * 43 (3.0) 43 (3.0) (3.1) 44 (3.1) * 48 (3.3) TOTAL HEAT OF REJECTI 6398 BTU/h (AT 90 F / WT 70 F) Note: The data without *marks should be used for reference. We reserve the right to make changes in specifications and design without prior notice. 31
32 F-801MWH-C APPROXIMATE Ambient Water Temp. (F) ICE PRODUCTI Temp. (F) PER 24 HR. 70 * 645 (293) 620 (281) 608 (276) (270) 585 (265) 574 (260) (255) * 550 (249) 541 (246) lbs./day ( kg/day) (241) 521 (236) * 485 (220) APPROXIMATE ELECTRIC 70 * CSUMPTI * watts * APPROXIMATE WATER 70 * 276 (1046) 342 (1294) 579 (2192) CSUMPTI PER 24 HR (1086) 354 (1339) 605 (2291) (TOTAL) (1119) * 368 (1392) 633 (2397) gal. / day (l/day) (1156) 381 (1442) * 693 (2622) EVAPORATOR OUTLET TEMP. 70 * 20 (-7) 20 (-7) 21 (-6) F ( C) (-6) 21 (-6) 21 (-6) (-6) * 21 (-6) 21 (-6) (-6) 21 (-6) * 22 (-6) HEAD PRESSURE 70 * 263 (18.5) 263 (18.5) 264 (18.6) (18.5) 263 (18.5) 264 (18.6) (18.5) * 263 (18.5) 264 (18.6) PSIG (kg/cm 2 G) (18.5) 263 (18.5) * 264 (18.6) SUCTI PRESSURE 70 * 46 (3.2) 46 (3.3) 47 (3.3) PSIG (kg/cm 2 G) (3.2) 46 (3.3) 47 (3.3) (3.2) * 46 (3.3) 47 (3.3) (3.2) 46 (3.3) * 47 (3.3) WATER FLOW FOR CDENSER 13 gal/h (AT 90 F / WT 70 F) PRESSURE DROP OF COOLING WATER LINE Less than 7 PSIG HEAT OF REJECTI FROM CDENSER 5155 BTU/h (AT 90 F / WT 70 F) HEAT OF REJECTI FROM COMPRESSOR 1050 BTU/h (AT 90 F / WT 70 F) Note: The data without *marks should be used for reference. We reserve the right to make changes in specifications and design without prior notice. 32
33 IV. Adjustment of Components 1. Adjustment of Water Regulating Valve (water-cooled model only) The water regulating valve or also called water regulator is factory-adjusted. No adjustment is required under normal use. Adjust the water regulator, if necessary, using the following procedures. 1) Attach a pressure gauge to the high-side line of the system. Or prepare a thermometer to check the condenser drain temperature. 2) Rotate the adjustment screw by using a flat blade screwdriver, so that the pressure gauge shows 260 PSIG (R-404A models/-f type), or the thermometer reads F, in 5 minutes after the icemaking process starts. When the pressure exceeds 260 PSIG, or the condenser drain temperature exceeds 104 F, rotate the adjustment screw counterclockwise. 3) Check that the pressure or the condenser drain temperature holds a stable setting. Adjustment Screw Adjustment Screw CW CCW Bottom View CW - Higher CCW - Lower 33
34 2. Adjustment of Flake Size To adjust the flake size, change the direction of the cutter head on the top of the auger, according to the following procedures: 1) Remove the bolt and the cutter head. FINE 2) The cutter head has two holes, one for fine flake and the other for coarse flake size. The unit is shipped from the factory in the fine flake position. COARSE 3) Place the cutter head so that the pin on the top of the auger fits into the selected hole. 4) Secure the cutter head by the bolt. 34
35 V. Service Diagnosis 1. No Ice Production PROBLEM POSSIBLE CAUSE REMEDY [1] The icemaker will a) Power Supply 1. position. 1. Move to position. not start. 2. Loose connection. 2. Tighten. 3. Bad contacts. 3. Check for contintinuity and replace. 4. Blown fuse. 4. Replace. [2] Water flow does not stop, and the icemaker will not start [3] Water has been supplied, but the icemaker will not start. b) Power Switch (Control Box) Off position. 1. Move to position. 2. Bad contacts. 2. Check for continuity and replace. c) Fuse (Control Box) 1. Blown out. 1. Check for short circuit and replace. d) Circuit Protect Relay 1. Miswiring. 1. Check power supply voltage and wire properly. e) Flush Timer 1. Flushing out. 1. Wait for 15 minutes. 2. Bad contacts. 2. Check for continuity and replace. f) Flush Switch 1. FLUSH position. 1. Move to ICE position. 2. Bad contacts. 2. Check for continuity and replace. g) Transformer 1. Coil winding opened. 1. Replace. h) Control Water Valve 1. Coil winding opened. 1. Replace. i) Shut-off Valve 1. Closed. 1. Open. 2. Water failure. 2. Wait till water is supplied. j) Plug and Receptacle 1. Disconnected. 1. Connect. (Control Box) 2. Terminal out of Plug or Receptacle. 2. Insert Terminal back in position a) Water Control Relay 1. Contact fused. 1. Replace. 2. Coil winding opened. 2. Replace. b) Float Switch 1. Bad contacts. 1. Check for continuity and replace. 2. Float does not move 2. Clean or replace. freely. c) Flush Water Valve 1. Valve seat clogged 1. Clean or replace and water leaking. d) Hoses 1. Disconnected. 1. Connect. a) Water Control Relay 1. Bad contacts. 1. Check for continuity and replace. b) Bin Control 1. Bad contacts. 1. Check for continuity and replace. 2. Activator does not move freely. c) Gear Motor Relay 1. Coil winding opened. 1. Replace. d) Control Timer (Printed Circuit Board) e) Gear Motor Protect Relay 2. Clean Axle and its corresponding holes or replace Bin Control. 2. bad contacts. 2. Check for continuity and replace. 1. Broken. 1. Replace. 1. Coil winding opened. 1. Replace. 2. Bad contacts. 2. Check for continuity and replace.
36 PROBLEM POSSIBLE CAUSE REMEDY a) Gear Motor Fuse 1. Blown Fuse. 1. See "3. [3]." Find out (BUSSMAN GMD the cause and replace 1.5A) the Fuse. [4] Water has been supplied, Fan Motor starts, but Gear Motor and Compressor will not start. [5] Gear Motor and Compressor start but operate intermittently. [6] Gear Motor starts, but Compressor will not start or operates intermittently. b) Thermal Protector (Gear Motor) a) Pressure Switch 1. Dirty Air Filter or Condenser. 2. Ambient or condenser water temperature too warm. 3. Condenser water pressure too low or off. (Water-cooled model only) a) X2 Relay on Control Timer 1. Bad contacts. 1. Check for continuity and replace. 1. Clean. 2. Get cooler. 3. Check and get recommended pressure. 4. Water Regulating 4. Adjust it lower. Valve set too high. (Water-cooled model only) 5. Fan not rotating. 5. See "3. [1] a) Fan Motor." 6. Refrigerant overcharged. 6. Recharge. 7. Refrigerant line or components plugged. 7. Clean and replace drier. 8. Bad contacts. 8. Check for continuity and replace. 9. Loose connections. 9. Tighten. 1. Bad contacts. 1. Replace.Check for continuity and replace. 2. Coil winding opened. 2. Replace Timer. b) Starter 1. Bad contacts. 1. Check for continuity and replace. 2. Coil winding opened. 2. Replace. 3. Loose Connections. 3. Tighten. c) Start Capacitor or 1. Defective. 1. Replace. Run Capacitor d) Compressor 1. Loose connections. 1. Tighten. 2. Motor winding opened or grounded. 2. Replace. [7] Gear Motor and Compressor start, but no ice is produced. 3. Motor Protector tripped. 3. Find out the cause of overheat or overcurrent. 1. Install a larger-sized e) Power Supply 1. Circuit Ampacity too low. conductor. a) Refrigerant Line 1. Gas leaks. 1. Check for leaks with a leak detector. Reweld leak, replace drier and charge with refrigerant. The amount of refrigerant is marked on Nameplate or Label. 2. refrigerant line clogged. 2. Replace the clogged component. 36
37 2. Low Ice Production PROBLEM POSSIBLE CAUSE REMEDY [1] Low ice production a) Refrigerant Line 1. Gas leaks. 1. See "1. [5] a) b) High-side Pressure Too High c) Expansion Valve (not adjustable) Refrigerant Line." 2. Refrigerant line clogged. 2. Replace the clogged component. 3. Overcharged. 3. Recharge. 1. Dirty Air Filter or 1. Clean. Condenser. 2. Ambient or 2. Get cooler. condenser water temperature too warm. 3. Condenser water pressure too low or off. [Water-cooled model only] 4. Fan rotating too slow. 5. Water Regulating Valve clogged. [Water-cooled model only] 6. Condensing unit out of order. 1. Low-side pressure too low. 2. Low-side pressure too high. 3. Check and get recommended pressure. 4. See "3 [1] a) Fan Motor." 5. Clean. 6. Check condensing unit. 1. Replace. 2. See if Expansion Valve Bulb is mounted properly, and replace the valve if necessary. 37
38 3. Other PROBLEM POSSIBLE CAUSE REMEDY [1] Abnormal noise a) Fan Motor 1. Bearing worn out. 1. Replace. 2. Fan blade deformed. 2. Replace fan blade. [2] Overflow from Reservoir (Water does not stop.) [3] Gear Motor Fuse blown frequently. 3. Fan blade does not move freely. b) Compressor 1. Bearings worn out, or cylinder valve broken. 2. Mounting pad out of position. c) Refrigerant Lines 1. Rub or touch lines or other surfaces. d) Gear Motor (Ice 1. Bearing or Gear Making) worn out / damaged. e) Evaporator 1. Too much pressure loss. 2. Scale on inside wall of Freezing Cylinder. 3. Replace. 1. Replace. 2. Reinstall. 1. Replace. 1. Replace. 1. Replace. 2. Remove Auger. Use "SCALE AWAY" or "LIME-A-WAY" solution to clean periodically. If the water is found hard by testing, install a softener. 1. Install a pressure Reducing Valve 1. Clean or replace. a) Water Supply 1. Water pressure too high. b) Control Water Valve 1. Diaphragm does not close. c) Float Switch 1. Bad contacts. 1. Check for continuity and replace. a) Power Supply 1. Too high or too low. 1. Connect the unit to a Voltage power supply of proper voltage. b) Ice Making Unit 1. Bearings or Auger worn out. 1. Replace Bearing or Auger. c) Bin Control 1. Bad contacts. 1. Check for continuity and replace. 2. Activator does not move freely. 2. Clean Axle and its corresponding holes or replace Bin Control. 38
39 VI. Removal and Replacement of Components IMPORTANT Ensure all components, fasteners and thumbscrews are securely in place after the equipment is serviced. IMPORTANT 1. The Polyolester (POE) oils used in R-404A units can absorb moisture quickly. Therefore it is important to prevent moisture from entering the system when replacing or servicing parts. 2. Always install a new filter drier every time the sealed refrigeration system is opened. 3. Do not leave the system open for longer than 15 minutes when replacing or servicing parts. 1. Service for Refrigerant Lines [a] Refrigerant Recovery The icemaker unit is provided with two refrigerant access valves - one on the low-side and one on the high-side line. Using proper refrigerant practices recover the refrigerant from the access valves and store it in an approved container. Do not discharge the refrigerant into the atmosphere. [b] Evacuation and Recharge [R-404A] 1) Attach charging hoses, a service manifold and a vacuum pump to the system. Be sure to connect charging hoses to both high-side and low-side access valves. IMPORTANT The vacuum level and vacuum pump may be the same as those for current refrigerants. However, the rubber hose and gauge manifold to be used for evacuation and refrigerant charge should be exclusively for POE oils. 2) Turn on the vacuum pump. Never allow the oil in the vacuum pump to flow backward. 3) Allow the vacuum pump to pull down to a 29.9" Hg vacuum. Evacuating period depends on pump capacity. 39
40 4) Close the low-side valve and high-side valve on the service manifold. 5) Disconnect the vacuum pump, and attach a refrigerant service cylinder to the highside line. Remember to loosen the connection, and purge the air from the hose. See the nameplate for the required refrigerant charge. Hoshizaki recommends only virgin refrigerant or reclaimed refrigerant which meets ARI Standard No be used. 6) A liquid charge is recommended for charging an R-404A system. Invert the service cylinder. Open the high-side, service manifold valve. 7) Allow the system to charge with liquid until the pressures balance. 8) If necessary, add any remaining charge to the system through the low-side. Use a throttling valve or liquid dispensing device to add the remaining liquid charge through the low-side access port with the unit running. 9) Close the two refrigerant access valves, and disconnect the hoses and service manifold. 10) Cap the access valves to prevent a possible leak. 2. Brazing DANGER 1. Refrigerant R-404A itself is not flammable at atmospheric pressure and temperatures up to 176 F. 2. Refrigerant R-404A itself is not explosive or poisonous. However, when exposed to high temperatures (open flames) R-404A can be decomposed to form hydrofluoric acid and carbonyl fluoride both of which are hazardous. 3. Always recover the refrigerant and store it in an approved container. Do not discharge the refrigerant into the atmosphere. 4. Do not use silver alloy or copper alloy containing arsenic. 5. Do not use R-404A as a mixture with pressurized air for leak testing. Refrigerant leaks can be detected by charging the unit with a little refrigerant, raising the pressure with nitrogen and using an electronic leak detector. 40
41 3. Removal and Replacement of Compressor IMPORTANT Always install a new drier every time the sealed refrigeration system is opened. Do not replace the drier until after all other repairs or replacement have been made. 1) Turn off the power supply, and remove the panels. 2) Remove the terminal cover on the compressor, and disconnect the compressor wiring. 3) Recover the refrigerant and store it in an approved container, if required by an applicable law. 4) Remove the discharge, suction and access pipes from the compressor using brazing equipment. WARNING When repairing a refrigerant system, be careful not to let the burner flame contact any electrical wires or insulation. 5) Remove the bolts and rubber grommets. 6) Slide and remove the compressor. Unpack the new compressor package. Install the new compressor. 7) Attach the rubber grommets of the prior compressor. 8) Sandpaper the discharge, suction and access pipes. 9) Place the compressor in position, and secure it using the bolts. 10) Remove plugs from the discharge, suction and access pipes. 11) Braze the access, suction and discharge lines (Do not change this order), while purging with nitrogen gas flowing at the pressure of 3-4 PSIG. 12) Install the new drier. 13) Check for leaks using nitrogen gas (140 PSIG) and soap bubbles. 41
42 14) Evacuate the system, and charge it with refrigerant. For the air-cooled and water-cooled models, see the nameplate for the required refrigerant charge and type. For the remote aircooled models, see the label on the control box. 15) Connect the terminals to the compressor, and replace the terminal cover in its correct position. 16) Replace the panels in their correct position, and turn on the power supply. 4. Removal and Replacement of Drier IMPORTANT Always install a new drier every time the sealed refrigeration system is opened. Do not replace the drier until after all other repairs or replacement have been made. 1) Turn off the power supply, and remove the panels. 2) Recover the refrigerant and store it in an approved container, if required by an applicable law. 3) Remove the drier using brazing equipment. 4) Install the new drier with the arrow on the drier in the direction of the refrigerant flow. Use nitrogen gas at the pressure of 3-4 PSIG when brazing the tubings. 5) Check for leaks using nitrogen gas (140 PSIG) and soap bubbles. 6) Evacuate the system, and charge it with refrigerant. For the air-cooled and water-cooled models, see the nameplate for the required refrigerant charge and type. For the remote air-cooled models, see the label on the control box. 7) Replace the panels in their correct position, and turn on the power supply. 42
43 5. Removal and Replacement of Expansion Valve IMPORTANT Sometimes moisture in the refrigerant circuit exceeds the drier capacity and freezes up at the expansion valve. Always install a new drier every time the sealed refrigeration system is opened. Do not replace the drier until after all other repairs or replacement have been made. 1) Turn off the power supply, and remove the panels. 2) Recover the refrigerant and store it in an approved container, if required by an applicable law. 3) Remove the expansion valve bulb at the evaporator outlet. 4) Remove the expansion valve cover, and remove the expansion valve using brazing equipment. 5) Braze the new expansion valve with nitrogen gas flowing at the pressure of 3-4 PSIG. WARNING Always protect the valve body by using a damp cloth to prevent the valve from overheating. Do not braze with the valve body exceeding 250 F. 6) Install the new drier. 7) Check for leaks using nitrogen gas (140 PSIG) and soap bubbles. 8) Evacuate the system. Charge it with refrigerant. For the air-cooled and water-cooled models, see the nameplate for the required refrigerant charge and type. For the remote air-cooled models, see the label on the control box. 9) Attach the bulb to the suction line. Be sure to secure the bulb using a band and to insulate it. 10) Place the new set of expansion valve covers in position. 11) Replace the panels in their correct position, and turn on the power supply. 43
44 6. Removal and Replacement of Water Regulating Valve (water-cooled model only) IMPORTANT Always install a new drier every time the sealed refrigeration system is opened. Do not replace the drier until after all other repairs or replacement have been made. 1) Turn off the power supply, remove the panels and close the water supply line shut-off valve. 2) Recover the refrigerant and store it in an approved container. 3) Disconnect the capillary tube using brazing equipment. 4) Disconnect the flare-connections of the valve. 5) Remove the screws and the valve from the bracket. 6) Install the new valve, and braze the capillary tube. 7) Install the new drier. 8) Check for leaks using nitrogen gas (140 PSIG) and soap bubbles. 9) Connect the flare-connections. 10) Evacuate the system, and charge it with refrigerant. See the nameplate for the required refrigerant charge and type. 11) Open the water supply line shut-off valve, and turn on the power supply. 12) Check for water leaks. 13) See IV. 1. Adjustment of Water Regulating Valve. If necessary, adjust the valve. 14) Replace the panels in their correct position. 44
45 7. Removal and Replacement of Evaporator Assembly 1) Turn off the power supply. 2) Remove the panels. 3) Move the flush switch to the "FLUSH" position. 4) Turn on the power supply and drain out all water from the water line. 5) Turn off the power supply. 6) Remove the strap connecting the spout to the chute assembly. 7) Remove the three thumbscrews and take off the spout from the evaporator. Cutter 8) Remove the bolt and lift off the cutter. 9) Remove the rubber O-ring and the nylon ring at the top of the evaporator. Extruding Head 10) Remove the four socket head cap screws and lift off the extruding head. 11) Replace the bearing inside the extruding head, if it exceeds the wear tolerance of 0.02" or is scratched. Note: Replacing the bearing requires a bearing press adaptor. If it is not available, replace the whole extruding head. Auger 12) Lift off the auger. If the area in contact with the bearing is worn out or the blade scratched, replace the auger. Evaporator Note: Skip the following steps 13) through 15) when the evaporator does not need replacement. 45
46 13) Recover the refrigerant and store it in an approved container, if required by an applicable law. IMPORTANT Always install a new drier every time the sealed refrigeration system is opened. Do not replace the drier until after all other repairs or replacement have been made. 14) Remove the bulb of the expansion valve. 15) Disconnect the brazing-connections of the expansion valve and the copper tube -low side from the evaporator, using brazing equipment. 16) Remove the two truss head machine screws and the strap securing the evaporator. 17) Disconnect the three hoses from the evaporator. 18) Remove the four socket head cap screws securing the evaporator with the bearinglower. 19) Lift off the evaporator. Bearing-Lower and Mechanical Seal 20) The mechanical seal consists of two parts. One moves along with the auger, and the other is fixed on the bearing-lower. If the contact surfaces of these two parts are worn or scratched, the mechanical seal may cause water leaks and should be replaced. 21) Remove the O-ring on the bearing-lower. 22) Remove the four bolts and the bearing-lower from the gear motor. Replace the bearing inside the bearing-lower, if it exceeds the wear tolerance of 0.02" or is scratched. Note: Replacing the bearing requires a bearing press adaptor. If it is not available, replace the whole bearing-lower. Gear Motor 23) Remove the coupling-spline on the gear motor shaft. 24) Remove the barrier on the top of the gear motor. 25) Remove the three socket head cap screws securing the gear motor. 46
47 26) Assemble the removed parts in the reverse order of the above procedure. WARNING Be careful not to scratch the surface of the O-ring, or it may cause water leaks. Handle the mechanical seal with care not to scratch nor to contaminate its contact surface. 27) When replacing the evaporator; (a) Braze the new evaporator with nitrogen gas flowing at the pressure of 3-4 PSIG. (b) Replace the drier. (c) Check for leaks using nitrogen gas (140 PSIG) and soap bubbles. (d) Evacuate the system. Charge it with refrigerant. For the air-cooled and water-cooled models, see the nameplate for required refrigerant charge and type. For the remote air-cooled models, see the label on the control box. 28) Move the flush switch to the "ICE" position. 29) Replace the panels in their correct position. 30) Turn on the power supply. 47
48 Rubber O-ring Nylon Ring Bolt Washer Auger Cutter Extruding Head Washer Mechanical Seal Socket Head Cap Screw O-ring Bearing - Lower Bolt Evaporator Washer Socket Head Cap Screw Washer Coupling - Spline Barrier Gear Motor 48
49 8. Removal and Replacement of Fan Motor 1) Turn off the power supply and remove the panels. 2) Remove the wire connectors from the fan motor leads. 3) Remove the fan motor bracket and fan motor. 4) Install the new fan motor. 5) Replace the fan motor bracket and the wire connectors. 6) Replace the panels in their correct position, and turn on the power supply. 9. Removal and Replacement of Control Water Valve 1) Turn off the power supply, remove the panels and close the water supply line shut-off valve. 2) Disconnect the terminals from the control water valve. 3) Loosen the fitting nut on the control water valve inlets, and remove the control water valve. Do not lose the packings inside the fitting nut. 4) Remove the water supply hose from the control water valve. 5) Install the new control water valve. 6) Assemble the removed parts in the reverse order of the above procedure. 7) Open the water supply line shut-off valve. 8) Check for water leaks. 9) Replace the panels in their correct position, and turn on the power supply. 49
50 10. Removal and Replacement of Flush Water Valve 1) Turn off the power supply, remove the panels and close the water supply line shut-off valve. 2) Remove the clamp and disconnect the hose from the flush water valve. Note: Water may still remain inside the evaporator. Be sure to drain the water into the drain pan. 3) Disconnect the terminals from the flush water valve. 4) Remove the flush water valve from the bracket. 5) Remove the drain pipe from the flush water valve. 6) Connect the drain pipe to the new flush water valve, and place the valve in position. 7) Connect the hose to the flush water valve and secure it with the clamp. 8) Pour water into the reservoir, and check for water leaks on the flush water valve. 9) Open the water supply line shut-off valve, and turn on the power supply. 10) Move the flush switch to the "ICE" position. 11) Check for water leaks. 12) Move the flush switch to the "FLUSH" position, and make sure water is flushing. 13) Move the flush switch to the "ICE" position. 14) Replace the panels in their correct position. 50
51 VII. Cleaning and Maintenance IMPORTANT Ensure all components, fasteners and thumbscrews are securely in place after any maintenance or cleaning is done to the equipment. 1. Preparing the Icemaker for Long Storage WARNING When shutting off the icemaker for an extended time, drain out all water from the water line and remove the ice from the storage bin. The storage bin should be cleaned and dried. Drain the icemaker to prevent damage to the water supply line at sub-freezing temperatures, using air or carbon dioxide. Shut off the icemaker until the proper ambient temperature is resumed. [Air-Cooled and Remote Air-Cooled Models] 1) Run the icemaker with the water supply line shut-off valve closed. 2) Open the drain valve and blow out the water inlet line by using air pressure. 3) Turn off the power supply. 4) Remove the front panel. 5) Move the flush switch on the control box to the FLUSH position. 6) Turn on the power supply, and then drain out all water from the water line. 7) Turn off the power supply. 8) Turn off the power switch on the control box. 9) Replace the front panel in its correct position. Air or CO2 Shut-off Valve Drain Valve 10) Close the drain valve. 11) Remove all ice from the storage bin, and clean the bin. 51
52 [Water-Cooled Models] 1) Turn off the power supply and wait for 3 minutes. 2) Turn on the power supply and wait for 20 seconds. 3) Close the water supply line shut-off valve. 4) Open the drain valve and quickly blow the water supply line from the drain valve to drain water in the condenser. 5) Follow the above steps 3) through 11) in [Air-Cooled and Remote Air-Cooled Models]. 2. Cleaning and Sanitizing Instructions WARNING 1. HOSHIZAKI recommends cleaning this unit at least once a year. More frequent cleaning, however, may be required in some existing water conditions. 2. To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners. 3. Always wear liquid-proof gloves to prevent the cleaning and sanitizing solutions from coming into contact with skin. [a] Cleaning Solution Dilute 4.8 fl. oz. (142 ml) of recommended cleaner Hoshizaki Scale Away or LIME-A-WAY (Economics Laboratory, Inc.) with 0.8 gallons (3 l) of warm water. This is a minimum amount. Make more solution if necessary. IMPORTANT For safety and maximum effectiveness, use the solution immediately after dilution. 52
53 [b] Cleaning Procedure The cleaning process will remove lime deposits from the water system. 1) Remove the front panel and top panel, then turn off the power supply. 2) Close the water supply line shut-off valve. 3) Remove all ice from the storage bin. 4) Move the flush switch to the FLUSH position. 5) Turn on the power supply and drain out all water from the water line. 6) Turn off the power supply. 7) Remove the strap connecting the spout to the chute assembly. 8) Remove the thumbscrews securing the spout and lift it off. 9) Pour the cleaning solution over the extruding head until the evaporator assembly and the reservoir are filled and the solution starts to overflow into the drain pan. Note: If there is excess scale on the extruding head, fill the evaporator assembly and reservoir as described above, then use a clamp on the reservoir hose between the reservoir and evaporator assembly to block flow. Pour additional cleaning fluid over the extruding head until the evaporator assembly is completely full. 10) Replace the spout and strap in their correct positions. 11) Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp on the reservoir hose in step 9, remove it before operation. 12) Move the flush switch to the ICE position, then turn on the power supply. Replace the top panel and front panel in their correct positions. Make ice using the solution until the icemaker stops making ice. 13) Remove the front panel. 14) Move the flush switch to the FLUSH position to drain the remainder of the solution. 15) After the solution is drained, move the flush switch to the ICE position. 16) Replace the front panel in its correct position. 17) Open the water supply line shut-off valve and supply water to the reservoir. 18) When the gear motor starts, remove the front panel and turn off the power supply. 19) Drain out all water from the water line. See 4) through 6). 53
54 [c] Sanitizing Solution Dilute 2.5 fl. oz. (74 ml or 5 tbs) of IMS-II Sanitizer or a 5.25% sodium hypochlorite solution (chlorine bleach) with 5 gallons (19 l) of warm water. IMPORTANT For safety and maximum effectiveness, use the solution immediately after dilution. [d] Sanitizing Procedure - Initial The sanitizing process will sanitize the icemaker. 1) Close the water supply line shut-off valve. 2) Remove the strap connecting the spout to the chute assembly. 3) Remove the thumbscrews securing the spout and lift it off. Remove the rubber O-ring and nylon O-ring at the top of the cylinder and also remove the packing between the spout and the chute. 4) Pour the sanitizing solution over the extruding head until the evaporator assembly and the reservoir are filled and the solution starts to overflow into the drain pan. 5) Remove the two thumbscrews securing the proximity switch to the chute assembly. 6) Remove the chute assembly from the icemaker. 7) Remove the packing at the bottom of the ice chute. 8) Remove the three ties and the chute insulation. 9) Remove the six wing nuts and two baffles. 10) Remove the two thumbscrews, the plate and the packing from the top of the ice chute, then remove the bin control assembly by sliding it slightly toward the chute opening and lifting it off. 11) Disassemble the bin control assembly by removing the two snap pins, shaft and actuator. 12) Soak the removed parts in.25 gallons (1 l) of sanitizing solution for 10 minutes then wipe them down. 13) Rinse the parts thoroughly. IMPORTANT If the solution is left on these parts, they will rust. 54
55 14) Replace all parts in their correct positions. IMPORTANT When installing the baffles, make sure that the bent surface (the one without the studs) faces the actuator so that the bent surface can guide the ice to the center of the actuator. 15) Move the flush switch to the ICE position, then turn on the power supply. Replace the top panel and front panel in their correct positions. Make ice using the solution until the icemaker stops making ice. [e] Sanitizing Procedure - Final 1) Remove the front panel and top panel, then turn off the power supply. 2) Move the flush switch to the FLUSH position. 3) Turn on the power supply and drain out all water from the water line. 4) Turn off the power supply. 5) Remove the strap connecting the spout to the chute assembly. 6) Remove the thumbscrews securing the spout and lift it off. 7) Pour the sanitizing solution over the extruding head until the evaporator assembly and the reservoir are filled and the solution starts to overflow into the drain pan. 8) Replace the spout and strap in their correct positions. 9) Allow the icemaker to sit for about 10 minutes before operation. 10) Move the flush switch to the ICE position, then turn on the power supply. Replace the top panel and front panel in their correct positions. Make ice using the solution until the icemaker stops making ice. 11) Remove the front panel. 12) Move the flush switch to the FLUSH position to drain the remainder of the solution. 13) After the solution is drained, move the flush switch to the ICE position. 14) Replace the front panel in its correct position. 15) Open the water supply line shut-off valve and supply water to the reservoir. 55
56 16) When the gear motor starts, remove the front panel and turn off the power supply. 17) Drain out all water from the water line. See 2) and 3). 18) Move the flush switch to the ICE position and run the icemaker. 19) Turn off the power supply after 30 minutes. 20) Pour warm water into the storage bin to melt all ice, and then clean the bin liner with the solution. 21) Flush out any solution from the storage bin. 22) Turn on the power supply and start the automatic icemaking process. IMPORTANT 1. After cleaning, do not use ice made from the sanitizing solution. Be careful not to leave any solution in the storage bin. 2. Follow carefully any instructions provided with the bottles of cleaning or sanitizing solution. 3. Never run the icemaker when the reservoir is empty. 56
57 3. Maintenance IMPORTANT 1. This icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemaker. 2. To have the optimum performance of this icemaker, the following consumable parts need periodical inspection, maintenance and replacement: Extruding Head Housing Gear Motor Auger Mechanical Seal These parts should be inspected at least once a year or every 10,000 hours of operation. Their service life, however, depends on water quality and environment. More frequent inspection and maintenance are recommended. Consult with your local distributor about inspection and maintenance service. To obtain the name and phone number of your local distributor, call Hoshizaki Technical Support at ) Stainless Steel Exterior To prevent corrosion, wipe the exterior occasionally with a clean and soft cloth. Use a damp cloth containing a neutral cleaner to wipe off oil or dirt build up. 2) Storage Bin and Scoop * Wash your hands before removing ice. Use the plastic scoop provided (bin accessory). * The storage bin is for ice use only. Do not store anything else in the bin. * Keep the scoop clean. Clean using a neutral cleaner and rinse thoroughly. * Clean the bin liner using a neutral cleaner. Rinse thoroughly after cleaning. 57
58 3) Air Filter (air-cooled model only) A plastic mesh air filter removes dirt or dust from the air, and keeps the condenser from getting clogged. As the filter gets clogged, the icemaker s performance will be reduced. Check the filter at least twice a month. When clogged, use warm water and a neutral cleaner to wash the filter. 4) Condenser (except water-cooled model) Check the condenser once a year, and clean if required by using a brush or vacuum cleaner. More frequent cleaning may be required depending on the location of the icemaker. 58
Hoshizaki America, Inc.
Hoshizaki America, Inc. Self-Contained Flaker Models F-330BAH(-C) A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73151 Issued: 8-2-2007 Revised: 4-22-2013 WARNING Only qualified
AFE424 SERVICE PARTS
This is the parts list for the AFE. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
MDT5N25 & MTD5N40 SERVICE PARTS
MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts
COMPRESSOR REPLACEMENT PROCEDURE
R-22 and R-410A COMPRESSOR REPLACEMENT PROCEDURE Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned Manual No.: 2100-003F Supersedes 2100-003E File: Volume I,
Hoshizaki America, Inc.
Hoshizaki America, Inc. Stackable Crescent Cuber Models KM-1301SAH/3, SWH/3, SRH/3 KM-1400SWH-M, SWH3-M KM-1601SAH/3, SWH/3, SRH/3 KM-1900SAH/3, SWH/3, SRH/3 KM-2100SWH3, SRH3 KM-2500SWH3, SRH3 KMH-2000SWH/3,
Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
COMPRESSOR REPLACEMENT PROCEDURE
COMPRESSOR REPLACEMENT PROCEDURE Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned Manual No.: 2100-003E Supersedes 2100-003D File: Volume I, Tab 1 Date: 06-25-02 Copyright
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
NME650 & FME800 INTRODUCTION. Table of Contents
INTRODUCTION To the owner or user: The service manual you are reading is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain,
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps Troubleshooting Submersible Pumps Fuse overload or circuit breaker trips when motor is started 1. Incorrect line voltage. Check the line
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: [email protected] Website: www.centrair.ca
Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060
4TTM3-SF-1 Service Facts Split System Cooling 4TTM3018-4TTM3060! CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE
Recharge Procedure for Telemark TVP-2000 and TVP-3500
Recharge Procedure for Telemark TVP-2000 and TVP-3500 Required items: 1.) Refrigeration service manifold. 2.) Charge recovery system. 3.) Dry nitrogen gas. If a high pressure cylinder is used, a pressure
Hoshizaki America, Inc.
Hoshizaki America, Inc. Self-Contained Cuber Models AM-50BAE AM-50BAE-DS AM-50BAE-AD AM-50BAE-ADDS A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73126 Issued: 12-22-2004 Revised:
Class 5 to 7 Truck and Bus Hydraulic Brake System
Class 5 to 7 Truck and Bus Hydraulic Brake System Diagnostic Guide 1st Edition * 5+0 Important Service tes The information in this publication was current at the time of printing. The information presented
Compressor Service & Maintenance Manual
Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance
PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION
NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS
INFORMATION INFORMATION ON THE TECHNOLOGY The -Frost refrigerators are different from the other static refrigerators in terms of their operational system. In normal refrigerators, in the freezing section,the
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
Hoshizaki America, Inc.
Hoshizaki America, Inc. Modular Cubelet Serenity Series Model FS-1500MLH-C Including Condensing Unit Model SRC-14H A Superior Degree of Reliability SERVICE MANUAL www.hoshizaki.com Number: 73190 Issued:
IMPORTANT SAFETY RULES TO FOLLOW
WARNING FLOOR & CARPET CLEANER Any piece of equipment can be dangerous if not operated properly. YOU are responsible for the safe operation of this equipment. The operator must carefully read and follow
ON-VEHICLE INSPECTION
Sight Glass I11244 ONVEHICLE INSPECTION 1. INSPECT REFRIGERANT VOLUME Observe the sight glass on the liquid tube. AC3 AC22F05 Test conditions: Running engine at 1,500 rpm Blower speed control switch: HI
Cooling system components, servicing
19-1 Cooling system components, servicing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate protection, cover the cap
T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200
INSTRUCTION MANUAL FOR: T15 AIR CONDITIONER McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleanthermal.com INSTRUCTION MANUAL TABLE OF CONTENTS
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.
Here are some pictures to show what s required when replacing the A/C compressor, expansion valve and receiver/drier on a 2001 Volvo V70. Even if you don t replace these A/C parts these pictures can help
Refrigeration System Installation & Operation Manual
Refrigeration System Installation & Operation Manual Manitowoc Foodservice Walk-In Division 2915 Tennessee Avenue North P.O. Box 550 Parsons, TN 38363 Phone: 800-225-9916 www.manitowocfsusa.com 550001058-3
Cooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate CFC Technologies, Inc. does not advocate the HCFC wholesale
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Trouble Shooting BD & TW Compressor Systems 12 and 24 Volt
Trouble Shooting BD & TW Compressor Systems 12 and 24 Volt Determine the Model. The data plate is on the left end near the wiring entrance. BD - BD air* TW - Tradewinds air** BDAW - BD air/water TWAW -
Please keep these operating instructions in a safe place.
Please keep these operating instructions in a safe place. Dear Customer: Check this product for visible damage immediately upon receipt. Inform the shipper if there is any shipping damage. Note that damage
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
LOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
Table Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not CFC advocate the wholesale changeover of HCFC HCFC refrigerants
FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions
FJ2 2 Ton Trolley Floor Jack Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.
TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR
3 Phase Air Conditioner Component R2A3**GHR DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER
SMD Rework Station TABLE OF CONTENTS
SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating
NME650R INTRODUCTION. Table of Contents. Parts Lists and Wiring Diagrams are located in the center of this manual, printed on yellow paper.
INTRODUCTION To the owner or user: The service manual you are reading is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain,
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:[email protected] www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000 10 mm open end wrench 12 mm open end wrench 9/16 open end wrench 5/8 open end wrench 11/16 open end wrench 9/16
Installation Instructions
CNPVU CNRVU Uncased Coils Upflow - Downflow Heating - Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
01-3 6820-11 6820-11 AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON 2010.01
682011 013 GENERAL 1. SPECIFICATIONS 682011 014 682011 2. REPAIR INSTRUCTIONS 1) Precautions for Working with R134a R12 refrigerant and R134a refrigerant are not compatible. These refrigerants must never
DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information
Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION)
Form #SB4-304AS AirSourceR SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION) Second only to refrigerant hose leaks, compressors have the highest rate
Hoshizaki America, Inc.
Hoshizaki America, Inc. Modular Flaker with "F-A" Control Board Models F-1001MAH(-C), MWH(-C), MRH(-C) F-1501MAH(-C), MWH(-C), MRH(-C) F-2001MWH, MRH(3)(-C), MLH FD-650MAH-C, MWH-C, MRH-C FD-1001MAH-C,
800-292-3279 916 638-0828
800-292-3279 916 638-0828 http://easycleansystems.com/heaters/heater-parts.html VAL6 KBE5S and KBE5L Service manual KBE5S 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel
Rules for Safe Operation
Rules for Safe Operation Important: Do not attempt to operate the CleanStation until you have read and understand all of the instructions in this manual. Failure to do so may result in injury. The machine
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50
11 COOLING SYSTEM SERVICE INFORMATION------------------------------------------------ 11-1 TROUBLESHOOTING----------------------------------------------------- 11-1 RADIATOR ------------------------------------------------------------------
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Operating instructions Cordless K 10253 impact wrench
Operating instructions Cordless K 10253 impact wrench Operational precautions General safety instructions warning! 1. Consider work area environment. Do not expose tools to rain. Do not use tools in damp
Safety, Operation and Maintenance Manual with Parts List
Safety, Operation and Maintenance Manual with Parts List 20-Gallon Wet/Dry Vac Important Information and Safety Instructions PLEASE READ BEFORE USE! # 961130020 9/10-Rev 1 20-Gallon Wet/Dray Vac TABLE
20 GALLON WET DRY VACUUM
20 Gallon Wet & Dry Vacuum 110" Water Lift Vac Motor 24" Front Mount Squeegee Assembly 50' Cord Special Tip Pour Feature Warranty Contractor Tool Kit Includes: Wet p/u Tool, Dry p/u Tool, Crevice Tool,
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
Installer s Guide 18-AH39D1-13
18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,
ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE
ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE Protected by one or more of the following U.S. Patents (3,507,354; 3,575,234; 3,596,936; 3,605,797; 3,685,329; 4,045,977; 4,698,982; 926,673 and
Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)
19 Engine - Cooling System (Page GR-19) Cooling system draining and filling general information Body components, layout Engine components, layout Radiator fan run-on checking Recommended mixture ratios
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
T-Series Air Conditioner T62 Model
INSTRUCTION MANUAL T-Series Air Conditioner T62 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200
Volkswagen Golf 5 2004-> VW Rabbit GTI 2006->
Стр. 1 из 24 Volkswagen Golf 5 2004-> VW Rabbit GTI 2006-> 19-1 Cooling system components Warning! Hot steam may escape when opening expansion tank. Wear protective goggles and protective clothing to prevent
INSTALLATION AND MAINTENANCE INSTRUCTIONS 4AC16LT SERIES. Split System Air Conditioner. Save these instructions for future reference WARNING
INSTALLATION AND MAINTENANCE INSTRUCTIONS 4AC16LT SERIES Split System Air Conditioner Save these instructions for future reference WARNING The equipment covered in this manual is to be installed by trained
DESIGN STANDARDS SECTION 23 60 00
PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.
MODEL 300505 INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping.
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual
UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to
01 12 COOLING SYSTEM COOLING SYSTEM. End of Toc. End Of Sie
LOCATION INDEX. 1 SERVICE WARNINGS...................... 2 ENGINE COOLANT LEVEL INSPECTION..................... 2 ENGINE COOLANT PROTECTION INSPECTION..................... 2 ENGINE COOLANT REPLACEMENT..
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Reverse Cycle Inverter Split System Air Conditioner
Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting
Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas
Cleaning Instructions, Pilot Replacement and Valve Change Model No.: 233010 Natural Gas 8mm open-end wrench 9mm open-end wrench 10mm open-end wrench 12mm open-end wrench 13mm open-end wrench Phillips screw
REMOTE AIR-COOLED CONDENSERS. Installation and Maintenance Data. Models 1-26. Bulletin H-IM-73A June 2000 Part Number 90800801.
Bulletin H-IM-73A June 2000 Part Number 90800801 Replaces H-IM-73 and H-IM-74 REMOTE AIR-COOLED CONDENSERS Models 1-26 Installation and Maintenance Data Table of Contents Inspection Installation... 3-4
ENGINE COOLING SYSTEM
ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,
Cleaning & Sanitisation
Cleaning & Sanitisation Notice: The information and/or procedures presented in the following demonstration(s) should be performed by a trained Water Cooler Service Technician only. Never attempt to service
REMOVAL AND INSTALLATION
303-01C-1 REMOVAL AND INSTALLATION Engine Body On Special Tool(s) Adapter For 303-D043 303-D043-02 or equivalent Special Tool(s) 303-01C-1 Turbocharger Lifting Bracket 303-1266 Wrench, Fan Clutch Nut 303-214
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177
T-SERIES Air Conditioners T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 88043249 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND
PWC-500/1000/1010/1500
SERVICE MANUAL for by Vertex Model PWC-500/1000/1010/1500 P/N man-7008 Table of Contents Introduction Cooler Set-up Remove Top Cover Remove/Replace Float Remove/Replace Hot Tank Faucet Repair Hot Tank
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.
The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. It will be available soon as
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N 89104461
PROAIR Air Conditioner CR29 Model INSTRUCTION MANUAL Rev. F 2015 Pentair Equipment Protection P/N 89104461 89104461 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3
Geyser-R Heat pump water heater Installation manual
Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING
SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING INDEX 1. Introduction 3 2. Objectives 3 3. Employment Opportunity 4 4. Course Structure 4 5. Entry Qualification 4 6. List
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
STEERING SYSTEM - POWER
STEERING SYSTEM - POWER 1990 Nissan 240SX 1990 STEERING Nissan - Power Rack & Pinion Axxess, Maxima, Pulsar NX, Sentra, Stanza, 240SX, 300ZX DESCRIPTION The power steering system consists of a rack and
PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA CONTROL & OPERATING INSTRUCTIONS The controls on your new
