Echotel Model 961/962 Ultrasonic Level Switches
|
|
|
- Gerard James
- 9 years ago
- Views:
Transcription
1 Echotel Model 961/962 Ultrasonic Level Switches D E S C R I P T I O N Increasing demands for compliance with safety systems and overfill protection has mandated more reliable point level measurement. Echotel Models 961 & 962 Ultrasonic Level Switches meet these demands with advanced transducer designs, extensive hazardous location approvals, and a new self-test technology. Model 961 offers the ultimate solution to reliable single point liquid level measurement. This advanced switch uses pulsed signal technology for superior performance in difficult process conditions, and to provide excellent immunity from sources of electrical noise interference. Extensive self-testing of the electronics and transducer make this advanced switch suitable for use in Safety Integrity Level (SIL) 2 loops. Model 962 is a dual point switch that can be used as a level controller, or to control pumps in an auto fill or auto empty mode. The tip sensitive lower gap performs well in aerated or foamy liquids, and can measure to within 1 4" of the vessel bottom. The rigidity of the unique flow-through upper gap allows separations of up to 128" (325 cm) between the upper and lower transducer gaps. F E A T U R E S Single or dual point liquid level measurement Advanced self-test technology provides unsurpassed testing of electronics, transducer, piezoelectric crystals, and electromagnetic noise Adjustable time delay for turbulent aerated liquids Relay output or ma current shift with separate malfunction indication Integral or remote mount electronics Pulsed signal technology Extensive FM, CSA, and ATEX explosion proof and intrinsically safe approvals Suitable for Safety Integrity Level (SIL) 2 loops Model 961 Model 962 A P P L I C A T I O N S High level alarm Low level alarm Overfill protection Pump protection Seal pot level Pump control I N D U S T R I E S Chemical Petrochemical Pulp and paper Food and pharmaceutical Power Water and wastewater
2 T E C H N O L O G Y B A S I C O P E R A T I O N Model 961/962 switches utilize ultrasonic energy to detect the presence or absence of liquid in a single or dual point transducer. Ultrasonic contact level technology uses highfrequency sound waves that are easily transmitted across a transducer gap in the presence of a liquid media, but are attenuated when the gap is dry. Model 961/962 switches use an ultrasonic frequency of 2 MHz to perform this liquid level measurement in a wide variety of process media and application conditions. The transducer uses a pair of piezoelectric crystals that are encapsulated in epoxy at the tip of the transducer. The crystals are made of a ceramic material that vibrates at a given frequency when subjected to an applied voltage. The transmit crystal converts the applied voltage from the electronics into an ultrasonic signal. When liquid is present in the gap, the receive crystal senses the ultrasonic signal from the transmit crystal and converts it back to an electrical signal. This signal is sent to the electronics to indicate the presence of liquid in the transducer gap. When there is no liquid present, the ultrasonic signal is attenuated and is not detected by the receive crystal. Transmit crystal Ultrasonic signal transmission across transducer gap Ultrasonic transducer Receive crystal P U L S E D S I G N A L T E C H N O L O G Y Challenging process conditions such as aeration, suspended solids, and high viscosities are easily handled with the pulsed signal technology utilized in the 961/962 switches. Pulsed signal circuitry drives the transmit piezoelectric crystal to produce powerful pulses of high-frequency ultrasonic energy. These ultrasonic pulses are readily transmitted through liquids, but are attenuated when the transducer gap is dry. This technology also provides excellent immunity from electromagnetic noise interference. Pulsed signal technology makes the 961/962 units more reliable than older continuous wave ultrasonic switches. Unlike many tuning forks, pulsed signal ultrasonic switches do not need to be configured for different media densities, making these units the most universally applied level switches on the market today. S A F E T Y I N T E G R I T Y L E V E L ( S I L ) Critical process control applications demand reliable instruments that provide high levels of safety. The introduction of standards such as IEC 61508, IEC and ISA 84, have generated interest in using Safety Instrumented Systems (SIS) as a means to define the reliability of instruments in a control loop. All versions of the Model 961/962 switches undergo a detailed performance evaluation called a Failure Modes, Effects and Diagnostics Analysis (FMEDA). Three key components of the FMEDA are the Safety Integrity Level (SIL), Safe Failure Fraction (SFF) and the average Probability of Failure on Demand (PFDavg). 961 Relay 961 Current Shift 962 Relay 962 Current Shift SIL 2 as 1oo1 2 as 1oo1 2 as 1oo1 2 as 1oo1 SFF 92.0% 91.4% 91.5% 91.8% PFDavg 1.77E E E E-04 2
3 A D V A N C E D S E L F - T E S T A N D D I A G N O S T I C S Ultrasonic switches are often used as the last means of detecting whether a process vessel will overflow and cause a spill of potentially hazardous liquids, or empty out and possibly cavitate the pumps. In these critical applications it is desirable to have a method of periodically testing the ultrasonic switch to ensure that it is functioning properly. Transducer & crystals Electronics Noise Model 961/962 switches feature an advanced self-test technology that not only tests the electronics, transducer, and piezoelectric crystals, but also tests for the presence of industrial sources of environmental noise. Should the switch detect any problems a malfunction output is generated to alarm the user, and a red LED is lit to indicate an alarm condition. Self-test is performed automatically and continuously several times per second to verify proper operation of 961/962 switches. In addition, a pushbutton is provided to initiate a manual self-test mode. Pressing this test button stops all transmit pulses, which simulates an electronics failure. This failure is reported as: Taking diagnostics one step further is the unique noise self-test mode feature that is standard in all 961/962 switches. This tests for electromagnetic and acoustical noise that can influence many instrumentation technologies. If high levels of environmental noise are detected, the electronics reports a fault condition to alert the user of potential instrumentation reliability concerns. A microprocessor in the 961/962 electronics continuously monitors all self-test data. Should a fault occur, the microprocessor can determine whether the malfunction is due to the electronics, transducer, piezoelectric crystals, or the presence of environmental noise. A pushbutton and Fault LED is used to assist in troubleshooting the switch: One flash of the Fault LED indicates a problem with the transducer or piezoelectric crystals Two flashes of the Fault LED indicates a problem with one of the electronics boards Three flashes of the Fault LED indicates excessive levels of environmental noise 3.6 or 22 ma (selectable) with current shift output units SPDT malfunction relay de-energizes with relay output units A D J U S T A B L E T I M E D E L A Y Turbulence and splashing can cause some fixed time response switches to produce false level alarms. Model 961/962 switches overcome this difficulty with an adjustable time delay feature. A potentiometer allows a 1 2 to 45 second delay to be set to disregard waves or splashes, and reliably detect the true liquid level. R E L I A B L E T R A N S D U C E R D E S I G N Dependable point level measurement begins with reliable sensor design. Over 30 years of ultrasonic level switch technology experience is behind the Model 961/962 single and dual gap transducers. The result is an extremely robust transducer design that offers superior performance in difficult process conditions. Model 961 single point has a tip-sensitive transducer with an arch-shaped gap for superior performance in aerated or foamy liquids. Dual point Model 962 features a tip sensitive lower gap and flow through upper gap. This robust design allows separations of 128 inches (325 cm) between the upper and lower transducer gaps. 3
4 A P P L I C A T I O N S T Y P I C A L Model 961 single point switches may be used for high or low level alarm, as well as for pump protection. The Model Fill Line High Alarm Dual Point Alarm 962 dual point unit is typically configured to measure high/low, high/high, or low/low levels. The single point 961 can be mounted vertically or horizontally in vessels, bridles, or pipes. The dual gap 962 is always top mounted. A broad selection of transducer materials allow the 961/962 to be used in a wide variety of process media. Metallic transducers include 316 SS, Hastelloy C, and Monel. The Pump Protection Low Alarm 316 SS transducer has a NACE construction option for sour gas service, and can also be built per ASME B31.1 and B31.3 piping codes. Thermoplastic transducers include Kynar and CPVC. These corrosion resistant plastic transducers feature a stiffening tube that runs the length of the transducer for extra rigidity. Kynar-faced 316 SS flange options are offered with the Kynar transducers. P U M P C O N T R O L A DIP switch on the Model 962 allows it to be configured to control level, or to function as a pump controller. In the pump control mode the unit can perform auto fill or auto empty of tanks, sumps, or wet wells. The tip sensitive lower gap allows liquid levels to be pumped down to within 1 4" from the bottom of the vessel. The rigidity of the flow through upper gap allows the 962 to be used even when sumps experience severe turbulence from vessel fill lines. H Y G I E N I C The hygienic version of the Model 961 features a deep drawn stainless steel electronics housing. Tri-Clamp and DN65 Varivent hygienic process connections are offered for use in food & beverage, pharmaceutical, and biotechnology applications. These hygienic transducers have 3-A (Authorization #596), EHEDG certification (per TNO Report # V4772/01) and a 20 R a finish to provide a uniform and ultra-smooth surface that inhibits microbial growth. Electron beam welding technology is utilized to facilitate a crevice-free surface inside the transducer tip. This allows these transducers to be used in a wide variety of hygienic applications where CIP (Clean-in-Place) is used to remove any contamination from the transducer surface. Spray Ball 4
5 E L E C T R O N I C S S P E C I F I C A T I O N S M O D E L / W I T H R E L A Y O U T P U T Supply Voltage 18 to 32 VDC, or 102 to 265 VAC, 50/60 Hz Relay Outputs 961: One DPDT level relay and one SPDT malfunction relay 962: Two SPDT level relays and one SPDT malfunction relay Relay Ratings DPDT: VAC, 250 VAC, and 30 VDC, VDC SPDT: VAC, 250 VAC, and 30 VDC, VDC Fail-safe Selectable for high or low level Power Consumption 961/962: Less than 3 watts Ambient Temperature -40 to +160 F (-40 to +70 C) M O D E L / W I T H C U R R E N T S H I F T O U T P U T Supply Voltage 11 to 35 VDC Current Shift Output 961: 8 ma normal operation, 16 ma level alarm (±1 ma) 962: 8 ma normal operation, 12 ma lower gap alarm, 16 ma upper gap alarm (±1 ma) 961/962: 3.6 ma or 22 ma selectable fault signal (±1 ma) Loop Resistance 104 ohms with 11 VDC input, 1100 ohms with 35 VDC input Fail-safe Selectable for high or low level Power Consumption 961/962 Less than 1 watt Ambient Temperature -40 to +160 F (-40 to +70 C) T R A N S D U C E R S P E C I F I C A T I O N S M O D E L 9 A 1 / 9 M 1 S I N G L E P O I N T Transducer Material Material Code (page 10) Operating Temperature Range Maximum Pressure Actuation Length 316 Stainless Steel A*, S, N, K -40 to +325 F (-40 to +163 C) 2000 psi (138 bar) 1" and 2" (3 and 5 cm) 316 Stainless Steel A*, S, N, K -40 to +325 F (-40 to +163 C) 1500 psi (103 bar) 3" to 130" (6 to 330 cm) Hastelloy C-276 B -40 to +325 F (-40 to +163 C) 2000 psi (138 bar) 1" and 2" (3 and 5 cm) Hastelloy C-276 B -40 to +325 F (-40 to +163 C) 1500 psi (103 bar) 3" to 130" (6 to 330 cm) Monel C -40 to +325 F (-40 to +163 C) 1200 psi (83 bar) 1" to 130" (3 to 330 cm) Kynar R -40 to +250 F (-40 to +121 C) see graph below 2" to 130" (5 to 330 cm) CPVC P -40 to +180 F (-40 to +82 C) see graph below 1" to 130" (3 to 330 cm) * Material Code A has a Cryogenic Transducer Option for -110 to +250 F (-80 to +120 C) operating temperature range M O D E L 9 A 2 / 9 M 2 D U A L P O I N T Transducer Material Material Code (see page 10) Operating Temperature Range Maximum Pressure Actuation Length 316 Stainless Steel A, K -40 to +325 F (-40 to +163 C) 1500 psi (103 bar) 5" to 130" (13 to 330 cm) CPVC P -40 to +180 F (-40 to +82 C) see graph below 5" to 130" (13 to 330 cm) Kynar Transducer Ratings CPVC Transducer Ratings Range with "NPT Range with 150# flange Range with PN16 flange Pressure (psi) Pressure (bar) Pressure (psi) Pressure (bar) Temperature ( F) Temperature ( C) Temperature ( F) Temperature ( C) 5
6 P E R F O R M A N C E S P E C I F I C A T I O N S Repeatability ±0.078" (2 mm) Response Time 1 2 second typical Time Delay Variable seconds on rising and falling levels Self-Test Automatic: Continuously verifies operation of electronics, transducer, piezoelectric crystals, and electrical noise Manual: Push button verifies operation of electronics, transducer, and piezoelectric crystals Shock Class ANSI/ISA-S71.03 Class SA1 Vibration Class ANSI/ISA-S71.03 Class VC2 Humidity 0 99%, non-condensing Electromagnetic Compatibility Meets CE requirements EN P H Y S I C A L S P E C I F I C A T I O N S Housing Material Cast aluminum A356-T6, cast 316 stainless steel, or deep drawn 304 stainless steel (hygienic housing) Cable Entry Dual 3 4" NPT, or M20 connections (one end is plugged) Gross Weight 961/962 Electronics: 2.2 lbs. (1.0 kg) 2" (5 cm) Transducer: 0.6 lbs. (0.3 kg) D I M E N S I O N A L S P E C I F I C A T I O N S I N C H E S ( m m ) 5.24 (133) 4.00 (102) 4.00 (102) 5.75 (146) 4.43 (113) 4.43 (113) 1.05 (26) Typical 1.8 (46) Typical 2.35 (60) Typical Actuation length for Tri-Clamp fitting Actuation length for NPT connection Actuation length for ANSI flange 0.25 (6) 0.25 (6) 0.25 (6).875 (22).875 (22).875 (22) Model 961 with Hygienic Housing with Tri-Clamp 16-AMP Fitting Model 961 with Cast Aluminum Housing with NPT Connection Model 961 with Cast Stainless Steel Housing and ANSI Flange 6
7 D I M E N S I O N A L I N C H E S ( m m ) S P E C I F I C A T I O N S 4.00 (102) 4.00 (102) 3.95 (100) 4.43 (113) 1.8 (46) Typical 2 Holes.38 (10) dia (51) 2.75 (70) 3.50 (89) 3.00 (76) ¾" NPT Conduit Connection 0.25 (6).875 (22) Actuation length for NPT connection Model 961/962 with Remote Electronics Remote Transducer with NPT Connection 4.00 (102) 4.00 (102) 4.43 (113) 4.43 (113) 1.8 (46) Typical 2.35 (60) Typical Actuation length B Actuation length B Actuation length A Actuation length A 0.25 (6).875 (22) Dia (6).875 (22) Dia. Model 962 with NPT Connection Model 962 with ANSI Flange 7
8 M O D E L N U M B E R / E L E C T R O N I C S BASIC MODEL NUMBER 961 Single-point electronics 962 Dual-point electronics Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP) INPUT POWER 2 18 to 32 VDC line-powered 5 11 to 35 VDC loop-powered to 265 VAC line-powered OUTPUT SIGNAL 0 ma current shift (available with Input Power code 5) D 5-amp gold flash relays (available with Input Power codes 2 or 7) HOUSING COVER 0 Standard housing cover 1 Glass window cover (available with Electronics Housing codes 0, 1, 4 or 5) MOUNTING 0 Integral 1 Remote (requires Connecting Cable from page 11) AGENCY APPROVAL FM/CSA Intrinsically safe, Non-Incendive 1 & Explosion Proof* (use with current shift Output Signal code 0) FM/CSA Explosion Proof & Non-Incendive 3 (use with relay Output Signal code D, and Electronics Housing codes 0, 1, 2 & 3) 7 FM/CSA Non-incendive (available with Output Signal codes 0 & D and Electronics Housing codes 4 & 5) A ATEX II 1G EEx ia IIC T5, Intrinsically safe (use with Output Signal code 0, and Electronics Housing codes 0, 1, 2, 3) C ATEX II 1/2G EEx d IIC T6, Flameproof (use with Output Signal code 0 or D, and Electronics Housing codes 0, 1, 2, 3) * Explosion Proof approvals not available with housing codes 4 & 5 ELECTRONICS HOUSING 0 Cast aluminum with 3 4" NPT dual conduit entries 1 Cast aluminum with M20 dual conduit entries 2 Cast SS with 3 4" NPT dual conduit entries 3 Cast SS with M20 dual conduit entries 4 Deep drawn SS with 1 2" NPT dual conduit entries 5 Deep drawn SS with M20 dual conduit entries 9 6 A 8
9 M O D E L N U M B E R S I N G L E P O I N T T R A N S D U C E R TRANSDUCER UNIT OF LENGTH A English (length in inches) M Metric (length in centimeters) Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP) MATERIALS OF CONSTRUCTION A 316/316L stainless steel S 316/316L with 20 Ra hygienic finish (use only with Process Connection codes 3T, 4T, or VV) B Hastelloy C-276 C Monel R Kynar* (use only with Process Connection codes 11, 23, 33, 43, BA, CA, DA) P CPVC (use only with Process Connection codes 11, 23, 33, 43, BA, CA, DA) N 316/316L stainless steel, NACE construction K 316/316L stainless steel, ASME B31.1 &B31.3 construction * Flanged Kynar transducers have Kynar faced 316 stainless steel flanges PROCESS CONNECTIONS THREADED CONNECTIONS " NPT 21 1" NPT 22 1" BSP (G1) HYGIENIC CONNECTIONS 3T 1 1 2" Tri-Clamp 16 AMP fitting 4T 2" Tri-Clamp 16 AMP fitting VV DN65 Varivent Type N ANSI RAISED FACE FLANGES 23 1" 150# ANSI RF flange 24 1" 300# ANSI RF flange 25 1" 600# ANSI RF flange " 150# ANSI RF flange " 300# ANSI RF flange " 600# ANSI RF flange 43 2" 150# ANSI RF flange 44 2" 300# ANSI RF flange 45 2" 600# ANSI RF flange EN/DIN FLANGES BA DN 25 PN 16 EN Type A BB DN 25 PN 25/40 EN Type A BC DN 25 PN 63/100 EN Type B2 CA DN 40 PN 16 EN Type A CB DN 40 PN 25/40 EN Type A CC DN 40 PN 63/100 EN Type B2 DA DN 50 PN 16 EN Type A DB DN 50 PN 25/40 EN Type A DD DN 50 PN 63 EN Type B2 DE DN 50 PN 100 EN Type B2 TRANSDUCER OPTIONS A Standard design C Cryogenic design to -110 F (-80 C) (available with Materials code A) ACTUATION LENGTH* (unit of length specified in second digit) 1" to 130" in 1" increments (Example: 4 inches = 004) 1" minimum for NPT process connections 2" minimum for BSP, hygienic, and flanged process connections 2" minimum for all Kynar transducers Available English ESP lengths: 1", 2", 4", 6", 8", 12" 3 cm to 330 cm in 1 cm increments (Example: 6 centimeters = 006) 3 cm minimum for NPT process connections 5 cm minimum for BSP, hygienic, and flanged process connections 5 cm minimum for all Kynar transducers Available metric ESP lengths: 3, 5, 10, 30 cm * For lengths longer than 130" (330 cm), contact the factory 9 1 9
10 M O D E L N U M B E R D U A L P O I N T T R A N S D U C E R TRANSDUCER UNIT OF LENGTH A English (length in inches) M Metric (length in centimeters) MATERIALS OF CONSTRUCTION A 316/316L stainless steel K 316/316L stainless steel, ASME B31.1 &B31.3 construction P CPVC (use only with Process Connection codes 11, 23, 33, 43, BA, CA, DA) PROCESS CONNECTIONS THREADED CONNECTIONS " NPT 21 1" NPT 22 1" BSP (G1) ANSI RAISED FACE FLANGES 23 1" 150# ANSI RF flange 24 1" 300# ANSI RF flange 25 1" 600# ANSI RF flange " 150# ANSI RF flange " 300# ANSI RF flange " 600# ANSI RF flange 43 2" 150# ANSI RF flange 44 2" 300# ANSI RF flange 45 2" 600# ANSI RF flange EN/DIN FLANGES BA DN 25 PN 16 EN Type A BB DN 25 PN 25/40 EN Type A BC DN 25 PN 63/100 EN Type B2 CA DN 40 PN 16 EN Type A CB DN 40 PN 25/40 EN Type A CC DN 40 PN 63/100 EN Type B2 DA DN 50 PN 16 EN Type A DB DN 50 PN 25/40 EN Type A DD DN 50 PN 63 EN Type B2 DE DN 50 PN 100 EN Type B2 Important: Use the A dimension as the actuation length code. The B dimension must also be specified in quote/order. Example: For a 962 with an A dimension of 18" and a B dimension of 7", specify actuation length code 018. Actuation length A Actuation length B min. 2" (5 cm) Minimum distance between actuation points A and B is 3" (8 cm) Maximum distance between actuation points A and B is 128" (325 cm) A DIMENSION ACTUATION LENGTH* (units specified in second digit) 5" to 130" in 1" increments 5" minimum for NPT process connections 6" minimum for BSP, and flanged process connections Example: 5 inches = cm to 330 cm in 1 cm increments 13 cm minimum for NPT process connections 15 cm minimum for BSP, and flanged process connections Example: 13 centimeters = 013 * For lengths longer than 130" (330 cm), contact the factory 9 2 A 10
11 M O D E L C O N N E C T I N G N U M B E R C A B L E ELECTRONICS MODEL 6 Remote cable for Model Remote cable for Model 962 CONNECTING CABLE LENGTH (FEET) Maximum Length: 150 feet Minimum Length: 10 feet Example: 12 feet = A G E N C Y A P P R O V A L S AGENCY APPROVED MODELS PROTECTION METHOD AREA CLASSIFICATION FM & CSA 96X-X0A0-X10 Explosion Proof Class I, Div. 1,Groups B, C, & D 96X-X0A0-X11 Class II, Div. 1, Groups E, F, & G 96X-X0A0-X12 Class III, Type 4X, IP 66, T6 96X-X0A0-X13 96X-X0A1-X10 96X-X0A1-X11 96X-XDA0-X30 96X-XDA0-X31 96X-XDA0-X32 96X-XDA0-X33 96X-XDA1-X30 96X-XDA1-X31 with transducers 9AX-XXXX-XXX or 9MX-XXXX-XXX 96X-XXAX-XXX or Non-Incendive Class I, Div. 2,Groups A, B, C, & D with transducers Class II, Div. 2, Groups E, F, & G 9AX-XXXX-XXX or Class III, Type 4X, IP 66, T4 9MX-XXXX-XXX 96X-50AX-X1X Intrinsically Safe Class I, Div. 1,Groups A, B, C, & D with transducers Class II, Div. 1, Groups E, F, & G 9AX-XXXX-XXX or Class III, Type 4X, IP 66, T4 9MX-XXXX-XXX ATEX 96X-XXAX-XC0 Flameproof Ex II 1/2 G, EEx d IIC T6 96X-XXAX-XC1 96X-XXAX-XC2 96X-XXAX-XC3 with transducers 9XX-AXXX-XXX 9XX-SXXX-XXX 9XX-BXXX-XXX 9XX-CXXX-XXX 9XX-NXXX-XXX 9XX-KXXX-XXX 96X-50AX-XA0 Intrinsically Safe Ex II 1 G, EEx ia IIC T5 96X-50AX-XA1 96X-50AX-XA2 96X-50AX-XA3 with transducers 9XX-AXXA-XXX 9XX-SXXA-XXX 9XX-BXXA-XXX 9XX-CXXA-XXX 9XX-NXXA-XXX 9XX-KXXA-XXX 0344 These units are in compliance with: 1. The EMC Directive: 89/336/EEC. The units have been tested to EN Directive 94/9/EC for equipment or protective system for use in potentially explosive atmospheres. 11
12 Q U A L I T Y The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. MAGNETROL is committed to providing full customer satisfaction both in quality products and quality service. The MAGNETROL quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product and service quality available. E S P Expedite Ship Plan Several ECHOTEL Model 961 units are available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. W A R R A N T Y All MAGNETROL electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, MAGNETROL will repair or replace the control at no cost to the purchaser (or owner) other than transportation. MAGNETROL shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some MAGNETROL products. For additional information, see Instruction Manual Belmont Road Downers Grove, Illinois Fax Jardin Drive, Units 1 & 2 Concord, Ontario Canada L4K 1X Fax Heikensstraat 6 B 9240 Zele, Belgium Fax Regent Business Ctr., Jubilee Rd. Burgess Hill, Sussex RH15 9TL U.K Fax Copyright 2012 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance Magnetrol & Magnetrol specifications logotype and are Echotel effective are registered with trademarks date of issue of Magnetrol and are International, subject Incorporated. to change without notice. Kynar is a registered trademark of Elf Atochem North America, Inc. Hastelloy is a registered trademark of HAYNES INTERNATIONAL, INC. (DELAWARE CORPORATION). Monel is a registered trademark of the INCO family of companies. Tri-Clamp is a registered trademark of Ladish Co. Varivent is a registered trademark of Tuchenhagen GmbH LTD BULLETIN: EFFECTIVE: August 2011 SUPERSEDES: November 2009
Echotel Model 910. Installation and Operating Manual. Ultrasonic Level Switch
Echotel Model 910 Installation and Operating Manual Ultrasonic Level Switch Read this Manual Before Installing This manual provides information on the Echotel Model 910 Ultrasonic Liquid Level Switches.
Thermatel Model TD1/TD2 Thermal Dispersion Flow/Level/Interface Switch
Thermatel Model TD1/TD2 Thermal Dispersion Flow/Level/Interface Switch D E S C R I P T I O N TD1 and TD2 Thermal Dispersion flow/level/interface switches provide a new level of performance and reliability
Thermatel Model TA1 Mass Flow Transmitter
Thermatel Model TA1 Mass Flow Transmitter D E S C R I P T I O N Thermatel Thermal Mass Flow Transmitter, Model TA1, provides a high level of performance in mass flow measurement of air and gases. Powerful
B40 Liquid Level Switch
B40 Liquid Level Switch D E S C R I P T I O N The Magnetrol B40 liquid level switch is specifically designed and constructed for high pressure, high temperature service conditions. F E A T U R E S Choices
Thermatel Enhanced Model TA2 Thermal Mass Flow Meter
Thermatel Enhanced Model TA2 Thermal Mass Flow Meter D E S C R I P T I O N The Thermatel Enhanced Model TA2 Thermal Mass Flow Meter provides reliable mass measurement for air and gas flow applications.
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
OPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
Liquid Level Limit Switch liquiphant T FTL 20
Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
200350 and 200355 Accelerometers
and Accelerometers Bently Nevada Asset Condition Monitoring Description The and Accelerometers are general purpose, casemounted seismic transducers designed for use with Trendmaster Pro Constant Current
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision J Features 4 to 20
Electronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
OPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output
133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
Interface Level And Point Level Analyzers & Sensors
Interface Level And Point Level Analyzers & Sensors Model 2511 Analyzer Model 2505 System Model 2120 System Royce now offers a complete line of Interface Level and Point Level Analyzers that make it possible
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MG Transmitter with Digital Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MG Transmitter with Digital Output SENSORS Document Part Number 550784 Revision J Data Sheet FEATURES Modbus
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter
www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
TEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
Lockout Specification BW Clip Maintenance-free single gas detector
Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than
Rosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features
GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
Proximity Transmitters and Seismic Vibration Transmitters
Proximity Transmitters and Seismic Vibration Transmitters TR1101 Seismic Vibration Transmitter The TR1101 is a cost-effective solution for monitoring case vibration on balance of plant machines. The TR1101
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
VEGAPULS PULSE RADAR FOR LEVEL MEASUREMENT VEGAPULS 60 SERIES
VEGAPULS PULSE RADAR FOR LEVEL MEASUREMENT VEGAPULS 60 SERIES Why Use RADAR? Are you tired of re-calibrating the 0-point on pressure transmitters or dp cells? Operating by using electromagnetic microwave
Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms
Data Sheet Models MT 3809 & 3819 Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms Broad range of flow capacities 2% Full scale accuracy Versatile
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
Micro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
Chapter2. Installation
Chapter2. Installation Power Supply Requirements The ULM-1000C operates from a DC supply of 20 30V and will typically draw less than 0.08A. All electronic products are susceptible to electrostatic shock,
Rosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)
DVC6200 SIS Digital Valve Controller Product Bulletin Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS) The FIELDVUE DVC6200 SIS digital valve controller is a HART
TEIP11-PS I/P signal converter for standard signals. Measurement made easy
Change from one to tw o c olumns Data Sheet 10/18-0.10-EN Rev. C TEIP11-PS I/P signal converter for standard signals Measurement made easy Proven and reliable concept Compact design Small dimensions, low
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
VIBRATION SWITCHES SOLID STATE
SOLID STATE VIBRATION SWITCHES The PMC/BETA electronic vibration switch makes available in a relatively low-cost device many of the benefits formerly found only in high-end protection systems. Model Adjustable
Microwave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
2 & 5-Wire Overfill Sensors
2 & 5-Wire Overfill Sensors Optic overfill sensors detect the presence of liquid at a preset level. The new Civacon Universal 2 & 5-Wire Sensor is fully compatible with all our current Sensors and Monitors,
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.
ISO-9001:2000 certified EE300 Series Electromechanical Inventory Level Measuring System Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION OPERATING PRINCIPLE The EE300 series level measuring system is a
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and
Series 510 Submersible Level Transmitters
Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable
Flow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A
DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Flowline, Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598-3015 Fax: (562) 431-8507 www.flowline.com 22 AUG
Velomitor Piezo-velocity Sensor
Specifications and Ordering Information Velomitor Piezo-velocity Sensor BENTLY NEVADA MADE IN U.S.A. VELOMITO PN 330500 100 mv/in/s (4 mv/mm/s) Description Velomitor Piezo-velocity Sensors measure absolute
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
1701/22 FieldMonitor Management Interface Module
1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides
Description. Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers
Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers R Description These accelerometers are intended for critical machinery applications where casing acceleration
O C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
Colima Visco and Colima Viscorol Magnetic Level Indicators
3.796.5275.200 IM-P329-02 CH Issue 1 Colima Visco and Colima Viscorol Magnetic Level Indicators Installation and Maintenance Instructions Colima Visco Colima Viscorol 1. Safety information 2. General product
Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial
sect. 05 9600 rev. 206/08/0 Pressure Gage and Swichgage Instruments OPL Series 4-/2 in. (4mm) Diameter Dial The OPL-series pressure Swichgage instruments are combination pressure indicating gages with
Worcester DS/DM Series UltraSwitch Switch box
Worcester DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position
FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
330505 Low Frequency Velocity Sensor
330505 Low Frequency Velocity Sensor Bently Nevada* Asset Condition Monitoring Description The Bently Nevada Low Frequency Velocity Sensor is designed to measure absolute (relative to free space) bearing
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
RTD Temperature Probe for the Food/Pharmaceutical Industry
[email protected] Data Sheet 902810 Page 1/9 RTD Temperature Probe for the Food/Pharmaceutical Industry For temperatures between -50 and +250 C Protection type up to IP69 according to DIN EN 60529 (IP69K
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications
Dialight Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Case Study: Rockline Case Study (Manufacturing)
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020
Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal
Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB
Air Sensor SAC Ex Manual AQ Elteknik AB ATEX Air Sensor SAC Ex ATEX Certified model Manual version 2.0 Oct 2010 AQ Elteknik AB 2 Table of contents 1. Manufacturer information... 4 Manufacture Declaration
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
1/2 NPTM. 29.21 mm 1.15. Nose cone fitting Ideal for clean liquids
PT-500 Submersible Liquid Level Transmitter 1.0 Hex 25.4 mm 7.0 177.8 mm Re-Usable cage fitting Ideal for dirty liquids 5.63 143 mm 5.33 136 mm 1/2 NPTM 3.5 88.9 mm 1.15 29.21 mm Nose cone fitting Ideal