MIXING VALVES. Quality, Service. A history of. and Innovation. Customer Service (704)

Size: px
Start display at page:

Download "MIXING VALVES. Quality, Service. A history of. and Innovation. Customer Service (704) 841-6000"

Transcription

1

2 A history of Quality, Service and Innovation Now in its ninth decade, Conbraco Industries, Inc. is a leading manufacturer of flow control products for U.S. and international markets. he company s headquarters is based in Matthews, North Carolina with manufacturing plants and foundries located in Pageland and Conway, South Carolina. Conbraco has a history of new product development and innovation that dates back to the company s inception in oday, the Conbraco line of products is marketed under the Apollo Valves brand and includes: ball valves, butterfly valves, backflow prevention devices, water pressure reducing valves, mixing valves, safety relief valves, water gauges, strainers, vacuum breakers, valve actuators and more. Conbraco s vertically integrated manufacturing ensures a consistency of production, testing, quality and availability. It s your assurance that Conbraco flow control products will deliver long term performance advantages. All Conbraco plants are registered to ISO 9001:2008 quality standards. he Conbraco line continues to expand - with new products, designs and advanced materials - to better serve the needs of our customers in the chemical processing, pulp and paper, petroleum, residential and commercial plumbing and heating markets, as well as manufacturing and other markets. hroughout this catalog, products that have a Lead Free* option will be identified with this logo. * LEAD FREE: he wetted surfaces of this product shall contain no more than 0.25% lead by weighted average. Complies with Federal Public Law ANSI 3rd party approved and listed. ** Any imported products are clearly identified as Apollo International M or Conbraco M International. 2 Conbraco Industries offers a wide range of Apollo products for potable and non-potable applications. When the use of lead free valves is required by code, specification or legislation, it is the sole responsibility of our customers to ensure that only lead free Apollo products are installed in systems intended for potable water service. Further information related to our product offering and the U.S. Safe Drinking Water Act (SDWA) is available at or by contacting Conbraco Customer Service.

3 APOLLO MIXING VALVES... Your Best Choice For Value And Protection No matter how big or small your job, you can trust Apollo thermostatic mixing valves to provide all the value and Code-compliant performance you re looking for. Conserving energy and assuring safe use of our water systems by those who depend on them has grown increasingly important in recent years. Government at every level is working with our industry to enhance and improve the safety of our hot water supplies. his brochure addresses the use of Apollo mixing valves to protect water users and extend energy efficiency. A PROPER BALANCE Maintaining proper water temperature in hot water supply systems is critical. Water stored and delivered at too high a temperature puts users at risk of scalding. But maintaining water at too low a temperature presents other risks. It can turn a tank or piping system into a breeding ground for bacteria potentially harmful to water users young and old. Delivering water at the optimum temperature is exactly what our Apollo thermostatic mixing valves are designed to do. FOR EVERY JOB Our Apollo family of mixing valves includes ASSE certified products to meet all your point-of-source and point-of use requirements. We also offer a full range of non-asse models designed specifically for the higher temperatures associated with hydronic and radiant heating systems. And they re built to resist corrosion. All valves feature a high-copper-content all bronze body and heavy duty stainless steel springs. Our mixing valves offer fingertip control of water temperatures up to 180 F and the convenience of easy in-line servicing. for additional information, submittal sheets and manuals, visit 3

4 ABLE OF CONENS Introduction...3 Hydronic empering Valves Series...5 Point of Source ASSE 1017 Mixing Valves 34A Series A-H Series Commercial High Capacity Mixing Valves 34C Series C High emperature...8 Point of Use ASSE 1070/1017 Mixing Valves 34B Series D Mini Series...11 Hi/Lo Mixing Valve - ASSE 1069/ HL Series Emergency Eye Wash/Face Wash Mixing Valve 34E Mixing Valves Application Chart ypical Mixing Valve Piping Schematic

5 SERIES HYDRONIC EMPERING VALVES he Apollo Model V ( Series) thermostatic mixing valve provides non-asse extension of water heater capacity and hot water temperature control in hydronic heating systems. Available in low or high temperature options for floor or baseboard applications. C FEAURES Low temperature range F (-L1 suffix) High temperature range F (-01 suffix) Stainless steel spring Corrosion resistant bronze body hermoplastic shuttle assembly Solder connections are standard In-line repairable Fingertip temperature control Made in USA - ARRA compliant D (REF.) B Part No. Low emp F Part No. High emp F Connection Size (in.) Height Dimensions Width Weight Lbs L Solder 1/ L Solder 3/ A for additional information, submittal sheets and manuals, visit 5

6 ASSE 1017 Point of Source Mixing Valves MVA (34A) Series/MVAH Hydronic Series he Apollo MVA thermostatic master mixing valves are designed for ASSE 1017 point of source applications. hey provide reliable hot water temperature control of potable and hydronic hot water distribution systems. FEAURES Superior thermostatic element technology for optimal performance, reliability and accuracy Integral inlet strainers and check valves are standard to protect against cross-flow and foreign particles in the piping system hermostat over-temperature control Maximum temperature limit option Fingertip temperature control Cold or hot water supply failure shut-off protection Multiple connection options to fit your specific needs High temperature version for hydronic/radiant heating applications Standard materials of construction meet the requirements of the EPA Safe Drinking Water Act Lead free option available - specify model 34ALF Made in USA - ARRA compliant A E C D APPROVALS ASSE emperature Actuated Mixing Valve for Hot Water Distribution Systems CSA B Plumbing Supply Fittings A A B SECION A-A PERFORMANCE RAING Maximum working pressure 150 psig (1034 kpa) Maximum working temperature 210 F (99 C) Cold water inlet temperature range F (4-27 C) Hot water inlet temperature range F (49-82 C) Minimum flow rate 1/2 gpm (1.9 lpm) Mixed water temperature range F (54-82 C) Mixed water temperature tolerance ±5 F (1.7 C) Cv rating 3.9 Flow rate at 30 psid(138kpa) 19 gpm (64 lpm) Maximum pressure differential 25% between hot & cold OPIONS Max emperature Adjustment Setting (B suffix) Preset to 120 F maximum temperature High emp Range (H) Radiant Heat Application 120 F-180 F (Not ASSE Certified) See 34A-H submittal sheet Lead Free construction certified 0.25% lead max. Model 34ALF 6 MAERIAL Body: ASM B584 Bronze Shuttle: Noryl Modified PPO (Polyphenylene Oxide) Sensor: Copper/Wax filled O-ring: Chloramine Resistant EPDM Spring: ASM A313 Stainless Steel Cap: ABS (Acrylonitrile Butadiene Styrene)

7 ASSE 1017 Point of Source Mixing Valves * MVA (34A) Series/MVAH Hydronic Series Model Lead Free Model# Order Lead Free Order # Connection ype Dimensions (in.) A B C D E F MVA12 MVA12-LF 34A213 34ALF213 1/2 FNP MVA34 MVA34 -LF 34A214 34ALF214 3/4 FNP MVA1 MVA1 -LF 34A215 34ALF215 1 FNP MVAS12 MVAS12 -LF 34A213S 34ALF213S 1/2 Solder MVAS34 MVAS34 -LF 34A214S 34ALF214S 3/4 Solder MVAS1 MVAS1 -LF 34A215S 34ALF215S 1 Solder MVAC12 MVAC12 -LF 34A213C 34ALF213C 1/2 CPVC MVAC34 MVAC34 -LF 34A214C 34ALF214C 3/4 CPVC MVAC1 MVAC1 -LF 34A215C 34ALF215C 1 CPVC MVAX12 MVAX12 -LF 34A213X 34ALF213X 1/2 PEX MVAX34 MVAX34 -LF 34A214X 34ALF214X 3/4 PEX MVAX1 MVAX1 -LF 34A215X 34ALF215X 1 PEX Size & Connection Order Unit Wt. (lbs) Standard F 120 F Adjustment Limit Stop High emp (120 F-180 F)* Model Lead Free Order # Lead Free Model # Order Model Lead Free Order # Lead Free Model # Order Model 1/2 FNP 34A213 MVA12 34ALF213 MVA12-LF 34A213B MVAB12 34ALF213B MVAB12-LF 34A213H MVAH12 3/4 FNP 34A214 MVA34 34ALF214 MVA34-LF 34A214B MVAB34 34ALF214B MVAB34-LF 34A214H MVAH34 1 FNP 34A215 MVA1 34ALF215 MVA1-LF 34A215B MVAB1 34ALF215B MVAB1-LF 34A215H MVAH1 1/2 Solder 34A213S MVAS12 34ALF213S MVAS12-LF 34A213BS MVABS12 34ALF213BS MVABS12-LF 34A213HS MVAHS12 3/4 Solder 34A214S MVAS34 34ALF214S MVAS34-LF 34A214BS MVABS34 34ALF214BS MVABS34-LF 34A214HS MVAHS34 1 Solder 34A215S MVAS1 34ALF215S MVAS1-LF 34A215BS MVABS1 34ALF215BS MVABS1-LF 34A215HS MVAHS1 1/2 CPVC 34A213C MVAC12 34ALF213C MVAC12-LF 34A213BC MVABC12 34ALF213BC MVABC12-LF 34A213HC MVAHC12 3/4 CPVC 34A214C MVAC34 34ALF214C MVAC34-LF 34A214BC MVABC34 34ALF214BC MVABC34-LF 34A214HC MVAHC34 1 CPVC 34A215C MVAC1 34ALF215C MVAC1-LF 34A215BC MVABC1 34ALF215BC MVABC1-LF 34A215HC MVAHC1 1/2 PEX 34A213X MVAX12 34ALF213X MVAX12-LF 34A213BX MVABX12 34ALF213BX MVABX12-LF 34A213HX MVAHX12 3/4 PEX 34A214X MVAX34 34ALF214X MVAX34-LF 34A214BX MVABX34 34ALF214BX MVABX34-LF 34A214HX MVAHX34 1 PEX 34A215X MVAX1 34ALF215X MVAX1-LF 34A215BX MVABX1 34ALF215BX MVABX1-LF 34A215HX MVAHX1 * Hydronic models 34A-H/MVAH not covered by ASSE Standards. MVA Headloss VS. Flow Rate Curve FLOW CURVE Flow curve is based on the following: Cold and hot water inlet pressures at 45 psig; cold water supply temperature at 55 ±5 F; hot water supply temperature at 140 ±5 F, and mixed water temperature at 105 ±5 F. for additional information, submittal sheets and manuals, visit 7

8 MVC (34C Series) Commercial High Capacity Mixing Valves 3/4-1 he Apollo Model MVC (34C Series) ASSE 1017 listed, high-capacity mixing valves are thermostatically controlled regulating valves designed for use in large commercial and institutional point of source and hydronic hot water systems or applications. Simple adjustment of water temperature from F or F. Lead Free valves are available. 1-1/4-2 34C-104/34C-105 FEAURES Sizes 3/4, 1, 1-1/4, 1-1/2, 2 FNP Standard temp range F (-01 suffix) High temp range F (use suffix H1 ) for hydronic/radiant heating systems Highest flow rates in its class, up to 165 gpm hreaded connections All-bronze and stainless steel construction Patented design for easy in-line maintenance Supply pressures to 150 psig U.S. Patent #6,328,219 ASSE 1017 listed CSA B125.3 Plumbing Fittings Lead free option available - specify model 34CLF Made in USA - ARRA compliant SPECIAL FEAURES Selected Apollo 34C mixing valves feature a two-piece shuttle with integral over-travel spring so they re smaller and easier to install than other high-capacity valves. Plus their patented snap-fit element retainer and shuttle with special finger-grip pads assure easy removal and servicing without the need for special tools. 34C-106/34C-108 ORDERING NUMBERS PRESSURE DROP (PSIG) 8 Size (in.) Part No. Standard emp F Part No. High emp F 3/4 34C C-104-H1 1 34C C-105-H1 1-1/4 34C C-106-H1 1-1/2 34C C-107-H1 2 34C C-108-H1 REV. 10/14/14 FLOW RAE (GPM)

9 MVB (34B Series) ASSE 1070/1017 Point of Use Mixing Valves he Apollo Model MVB (34B Series) thermostatic mixing valves are designed to control and limit the volumes of cold and hot water required to deliver mixed water at a predetermined temperature either from the point of source or point of use application for single or multiple fixtures. Lead Free valves are available with various end connections. FEAURES Highest capacity that meets ASSE 1070 Superior thermostatic element technology for optimum reliability, dependability and accuracy Integral strainers and check valves provide protection against cross-flow and foreign particles hermostat over-temperature protection amper resistant locking cap feature Maximum temperature setting adjustment Meets the requirements of the EPA Safe Drinking Water Act Instantaneous cold or hot water supply failure shut-off protection Multiple connection options to fit your specific needs Lead free option available - specify model 34BLF Made in USA - ARRA compliant APPROVALS ASSE emperature Actuated Mixing Valve for Hot Water Distribution Systems ASSE Water emperature Limiting Device CSA B Plumbing Supply Fittings PERFORMANCE RAING Maximum supply pressure 150 psig (1034 kpa) Maximum working temperature 210 F (99 C) Hot water inlet temperature range F (49-82 C) Mixed water temperature range F (27-49 C) Mixed water temperature tolerance ± 3 F (1.7 C) Minimum flow rate 1.5 gpm (5.7 lpm) Maximum pressure differential between hot & cold 25% Minimum inlet/outlet temperature differential 15 F for additional information, submittal sheets and manuals, visit REV. 2/27/14 9

10 MVB (34B Series) cont. ASSE 1070/1017 Point of Use Mixing Valves Model Lead Free Model # Order Lead Free Order # Connection ype A B C D E F Unit Wt. (lbs) MVB12 MVB12-LF 34B213 34BLF213 1/2 FNP MVB34 MVB34-LF 34B214 34BLF214 3/4 FNP MVB1 MVB1-LF 34B215 34BLF215 1 FNP MVBS12 MVBS12-LF 34B213S 34BLF213S 1/2 Solder MVBS34 MVBS34-LF 34B214S 34BLF214S 3/4 Solder MVBS1 MVBS1-LF 34B215S 34BLF215S 1 Solder MVBC12 MVBC12-LF 34B213C 34BLF213C 1/2 CPVC MVBC34 MVBC34-LF 34B214C 34BLF214C 3/4 CPVC MVBC1 MVBC1-LF 34B215C 34BLF215C 1 CPVC MVBX12 MVBX12-LF 34B213X 34BLF213X 1/2 PEX MVBX34 MVBX34-LF 34B214X 34BLF214X 3/4 PEX MVBX1 MVBX1-LF 34B215X 34BLF215X 1 PEX

11 MVD (34D Series) ASSE 1070 Point of Use Mini Mixer Valves he Apollo MVD (34D Series) Mini hermostatic mixing valves are designed for ASSE 1070 Point of Use temperature control applications with a single fixture using proven ASM grade materials. hese valves will hold a desired temperature within ± 3 F and will shut off flow in the event of hot or cold water failure. hey come equipped with a tamper-resistant high temperature limit stop to prevent adjustment above 120 F. FEAURES amper resistant locking control knob Adjustable maximum temperature limit stop Crush proof integral check valves Hot/cold water failure protection Single outlet model for sensor faucets Bypass fitting option for dual fixture faucets Satin chrome plating option 3/8 compression or hose connections Mounting bracket included Lead free option available - specify model 34DLF Made in the USA - ARRA compliant PERFORMANCE RAING Outlet temperature range (85 F F) Maximum pressure: 125 psig Maximum inlet temperature: 210 F Minimum supply pressure 30 psi (207 kpa) Minimum inlet/outlet temperature differential 15 F Maximum hot/cold pressure differential 25% APPROVALS ASSE Performance Requirements for Water emperature Limiting Devices CSA B Plumbing Fittings Model Lead Free Model # Order Lead Free Order # Description Weight MVD MVD-LF 34D DLF /8 Single Outlet Bronze.82 MVDR MVDR -LF 34D DLF /8 Single Outlet Chrome.82 MVDB MVDB-LF 34D302B1 34DLF302B1 3/8 Double Outlet Bronze 1.0 MVDBR MVDBR-LF 34D302B17 34DLF302B17 3/8 Double Outlet Chrome 1.0 for additional information, submittal sheets and manuals, visit 11

12 34HL Series Hi/Lo Mixing Valve ASSE 1069/1017 he 34HL Mixing Valve uses proven Apollo thermostatic control to produce a consistent mix of water from low through high flow range. his single assembly controls mixed water temperatures to multiple-outlet shower and sink installations. It s the ideal choice in new construction or retrofits in nursing homes, prisons, hospitals, schools, gymnasiums, airports and other facilities where constant safe water temperature needs to be maintained at several outlets without the use of independent ASSE 1016 shower valves. FEAURES he Apollo 34HL is an advanced hermostatic Mixing Valve capable of maintaining safe, consistent temperature control of water at low and high flows to within ± 3.6 F. he 34HL will provide consistent temperature control at flow rates as high as 60 GPM and as low as 1.5 GPM, including mid-range flow between high and low. his high quality Apollo valve performs its function without requiring recirculation pumps like other systems in order to achieve low flow control. Integral strainers and checks are provided at the hot and cold supply inlets for greater reliability and performance. hese cast bronze thermostatic mixing valves are manufactured to the same exacting standards that have made the Apollo name famous for durability and reliability. Made in USA - ARRA compliant Product Specifications Maximum Static Pressure 150 psig (1034 kpa) Maximum Water emperature 200 F (93 C) Minimum Flow ASSE 1069 & gpm (5.7 Ipm) emperature Adjustment Range 90 F F Maximum Inlet Pressure Differential 30 psi (207kpa) Inlet Connection 1 NP Outlet Connection 1-1/4 NP emperature Gauge (1) F Pressure Gauge (3) psi Shipping Weight 36 lbs OPERAION he 34HL design is patented with a variable fluid flow assembly and dual thermal actuated controls for either low or high flow conditions. he passages are calibrated to control water temperature during all flow conditions without a dead zone between low and high flow. he 34HL also provides fluid shutoff as required by ASSE 1069 in the case that either the hot or cold supply lines fail (or are shut off for any reason) to prevent scalding. he valve can be tamper-resistant to limit the water temperature from exceeding safe conditions as required by ASSE he valve also meets the requirements of ASSE 1017 for Point of Source Applications. his device will service end use fixture fittings, including but not limited to, gang showers and sitz baths, by supplying tempered water at a preset temperature through a single supply pipe and will meet ASSE standard ASSE 1069 devices are designed to reduce the risk of scalding and thermal shock during changes in hot or cold water supply pressure or temperature, or loss of cold water supply. 12

13 34HL Series Hi/Lo Mixing Valve - ASSE 1069/1017 United States Patent US 6,929,188 B2 SANDARD APPROVALS ASSE 1069-Automatic emperature Control Mixing Valves his device will control outlet water temperature to individual or multiple fixtures within 3.6 F to reduce the risk of scalding or thermal shock. his device is intended to be installed where the bather has no access to the temperature adjustment, and where no further mixing occurs downstream of the device. he Apollo 34HL AC will meet the performance requirements of ASSE 1069 at flow as low as 1.5 GPM up through maximum flow rate. ASSE 1017-emperature Actuated Mixing Valves for Hot Water Distribution Systems his device will control outlet set water temperature to hot water distribution systems near the hot water source within 3 F below 2 GPM and within 5 F above 5 GPM. OPIONS: 34HL Nickel plated automatic temperature controller 34HLBOX01 - Cabinet, flush mount, SS 34HLBOX02 - Cabinet, flush mount, CS powder coat 34HLBOX03 - Cabinet, wall mount, SS 34HLBOX04 - Cabinet, wall mount, CS powder coat Flow Capacity Min. Flow Pressure Drop Across Valve Model to ASSE psi (69 kpa) 20 psi (138 kpa) 30 psi (207 kpa) 45 psi (310 kpa) 34HL gpm 22 gpm 42 gpm 52 gpm 60 gpm 6 lpm 83 lpm 159 lpm 197 lpm 227 lpm for additional information, submittal sheets and manuals, visit 13

14 MVE (34 E Series) Emergency Eye Wash/Face Wash Mixing Valve he Apollo Model MVE (34E Series) emergency mixing valves are designed to control the cold and hot water temperature to deliver tepid water at a predetermined temperature to emergency eyewash/ facewash fixtures. he device provides a precise temperature and flow control in the event of cold water, hot water and thermostatic element failures. FEAURES Hot and cold water supply failure protection patented design (US Patent 6,926,20 B2) epid water temperature limit control and adjustment epid water temperature adjustment handle with locking mechanism for tamper-resistant protection and inadvertent adjustment Integral inlet check valves and strainers to provide protection against cross-flow and foreign particles Superior thermostatic element technology for optimum reliability, dependability and accuracy hermostatic element failure and over-travel protection High efficiency and positive shut-off check valves In-line accessibility and serviceability of failure protection module and mixing valve internal components Meets the requirements of the EPA Safe Drinking Water Act Corrosion resistant components Single cartridge design of failure protection module for easy service and maintenance. Integral hot water by-pass Positive shutoff of hot supply when cold supply is lost Lead free option available - specify model 34ELF Made in USA - ARRA compliant APPROVALS ASSE emperature Actuated Mixing Valves for Plumbed Emergency Equipment ANSI/ISEA Z Emergency Eyewash & Shower Equipment FLOW (GPM) PRESSURE DROP (PSIG) 14

15 MVE (34E Series) Emergency Eye Wash/Face Wash Mixing Valve PERFORMANCE RAING Maximum working pressure Hot water inlet temperature range Cold water inlet temperature range epid water temperature adjustment range 150 psig (1034 kpa) F (49-82 C) F ( C) F ( C) Mixed water temperature tolerance ± 5 F (2.8 C) Flow 30 psig (206.9 kpa) differential 15 gpm (56.8 lpm) Cold water 30 psi (207 kpa) differential 13.5 gpm (51 lpm) (Note: he cold water supply shall be at least 20 F (-6.7 C) lower than the outlet water temperature setting) CONNECION SIZE 1/2 HREADED 1/2 SOLDER 3/4 HREADED 3/4 SOLDER BASIC VALVE MODEL # MVE12 MVES12 MVE34 MVES34 ORDERING # 34E103 34E103S 34E104 34E104S INCLUDES OULE MODEL # MVE12G MVES12G MVE34G MVES34G EMPERAURE GAUGE ORDERING # 34E113 34E113S 34E114 34E114S INCLUDES OULE EMP. GAUGE MODEL # MVE12GB MVES12GB MVE34GB MVES34GB AND INLE BALL VALVES ORDERING # 34E123 34E123S 34E124 34E124S LEAD FREE BASIC VALVE MODEL # MVE12LF MVES12LF MVE34LF MVES34LF ORDERING # 34ELF103 34ELF103S 34ELF104 34ELF104S DIMENSIONS & WEIGHS A (in.) B (in.) C (in.) D (in.) E (in.) F (in.) G (in.) UNI W. (lbs.) E YPICAL INSALLAIONS Note: Piping and installation of the device must be in accordance to federal, state, and local plumbing codes. Note: If the valve is some distance from the hot water source, recirculation is required to keep the hot water supply temperature within the required operational limits for additional information, submittal sheets and manuals, visit 15

16 APOLLO MIXING VALVES APPLICAION CHAR - Point of Source Series 34A-H Series Radiant Heat 34A Series ASSE 1017 Apollo 34 Series mixing valves help extend hot water supply and enhance the life and accuracy of hydronic thermostats in residential and small commercial systems. hese valves may be used to increase draw capacity of automatic storage water heaters. hey save hot water and energy by automatically regulating the mix of hot water with cold. Water temperatures can be adjusted by simply turning the yellow knob to the desired setting. Sizes 1/2, 3/4 solder Corrosion resistant bronze body and stainless steel spring Easy installation Apollo 34H Series mixing valves are ideal for use with domestic and commercial boilers and all types of radiant systems. hey are available in a variety of pipe end connections and are equipped with element over-travel protection. Also the 34H Series mixing valves offer integral checks to prevent cross-connection of temperatures. Sizes 1/2, 3/4, 1 Maximum rated working pressure 125 psig Mixed temperature range is 120 F to 180 F. Corrosion resistant cast bronze body For tankless coils, water heaters, boilers and solar energy systems Outlet temperatures from 120 F to 130 F (110 F to 150 F optional) Union tailpieces and union nuts, standard Designed to make maintenance fast and easy Glass-filled Noryl shuttle Apollo 34A Series mixing valves provide thermostat control of temperatures in residential, commercial and non-potable hot water systems. hey are ASSE 1017 certified and designed for use with water heaters and boilers. During operation, the valve redistributes and extends safe hot water from the heater to various sections of a building s water system. 34A Series mixing valves offer integral checks to prevent cross-connection of temperatures. hey also enable the contractor to direct mount the unit to the heater or boiler instead of heat trapping the valve. Sizes 1/2, 3/4, 1 Highest flow capacity in their class Maximum rated working pressure of 125 psig Easy temperature control from 85 F to 140 F. Corrosion resistant cast bronze body Union tailpieces and union nuts, standard Easily accessible internals allow in-line servicing Glass-filled Noryl shuttle 34C Series ASSE 1017 Apollo 34C Series high capacity mixing valves are ASSE 1017 certified. Also available in a high temperature model, these large capacity valves are designed for use in large commercial and institutional hot water systems. Sizes 3/4-2 Controlled temperature range is 90 F to 140 F Industry leading flow rates (130 F to 180 F optional) Corrosion resistant cast bronze body All replaceable parts accessible from single point Stainless steel and thermoplastic internals In-line repairable Maximum rated pressure 150 psig Glass-filled Noryl shuttle 34HL Series ASSE 1017/ASSE Hi/Lo Mixer Apollo 34HL single assembly controls mixed water temperatures to multiple-outlet shower and sink installations. It s the ideal choice in new construction or retrofits in nursing homes, prisons, hospitals, schools, gymnasiums, airports and other facilities where constant safe water temperature needs to be maintained at several outlets without the use of independent ASSE 1016 shower valves. Capable of maintaining safe, consistent temperature control of water at low and high flows to within ± 3.6 F Provides consistent temperature control at flow rates as high as 60 GPM and as low as 1.5 GPM, including mid-range flow between high and low Performs without requiring recirculation pumps like other systems in order to achieve low flow control Integral strainers and checks are provided at the hot and cold supply inlets for greater reliability and performance. Manufactured to the same exacting standards that have made the Apollo name famous for durability and reliability Units can be mounted in parallel for extra large flow requirements

17 APOLLO MIXING VALVES APPLICAION CHAR - Point of Use 34D Series ASSE 1070 Apollo 34D Series thermostatic Mini Mixer valves are dual ASSE 1070 certified and designed as the ultimate single fixture valve, with a mixed accuracy of +/- 2 F. wo designs are available depending on the application; single outlet design for sensor type faucets and double outlet design for standard connections. Compact, space saving design 3/8 compression x 3/8 compression connections Factory equipped with integral checks Corrosion resistant cast bronze body Stainless and thermoplastic internals Bypass tee option for cold water connection Chrome plating option 34B Series ASSE 1070/ASSE HL Series ASSE 1069/ASSE E Series ASSE 1071 Apollo 34B Series thermostatic mixing valves are dual ASSE 1070 and 1017 certified for point-of-use applications and provide enough capacity to protect up to twelve separate fixtures while maintaining an accuracy of +/- 3 F. hey offer easy adjustment of water temperatures. In accordance with ASSE 1070 standards, Series 34B valves come with maximum set point control features. Sizes 1/2, 3/4, 1 Controlled temperatures from full cold up to 120 F. Corrosion resistant bronze body Union tailpieces, nuts, standard NP, solder, CPVC and PEX connections Hi/Lo Mixer Apollo 34HL is dual ASSE 1069 and 1017 certified as Point of Source and Point of Use. his thermostatic device will service multiple enduse fixture fittings, including but not limited to, gang showers and sitz baths, by supplying tempered water at a preset temperature through a single supply pipe and will meet ASSE standard ASSE 1069 devices are designed to reduce the risk of scalding and thermal shock during changes in hot or cold water supply pressure or temperature, or loss of cold water supply. Capable of maintaining safe, consistent temperature control of water at low and high flows to within ± 3.6 F Provides consistent temperature control at flow rates as high as 60 GPM and as low as 1.5 GPM, including mid-range flow between high and low Performs without requiring recirculation pumps like other systems in order to achieve low flow control Integral strainers and checks are provided at the hot and cold supply inlets for greater reliability and performance. Apollo 34E Emergency Mixing Valves are designed to control the cold and hot water temperature to deliver tepid water at a predetermined temperature to emergency eyewash/facewash fixtures. he device provides a precise temperature and flow control in the event of cold water, hot water and thermostatic element failures. Complies with ANSI Z & ASSE Hot and cold water supply failure protection patented design (US Patent 6,926,20 B2) epid water temperature limit control and adjustment epid water temperature adjustment handle with locking mechanism for tamper-resistant protection and inadvertent adjustment Integral inlet check valves and strainers to provide protection against cross-flow and foreign particles Superior thermostatic element technology for optimum reliability, dependability and accuracy In-line repairable Glass-filled Noryl shuttle Factory equipped with integral checks and strainers Locking cap feature Manufactured to the same exacting standards that have made the Apollo name famous for durability and reliability Units can be mounted in parallel for extra large flow requirements Cabinets available Emergency Eye Wash / Face Wash hermostatic element failure and over-travel protection High efficiency and positive shut-off check valves In-line accessibility and serviceability of failure protection module and mixing valve internal components Meets the requirements of the EPA Safe Drinking Water Act Corrosion resistant components Single cartridge design of failure protection module for easy service and maintenance. for additional information, submittal sheets and manuals, visit 17

18 YPICAL MIXING VALVE PIPING SCHEMAIC YPICAL MIXING VALVE PIPING SCHEMAIC MVA SERIES MVB SERIES MVC SERIES MVHL SERIES COLD WAER INLE YPICAL INSALLAION POIN OF SOURCE (NO RECIRCULAION SYSEM) C H HEA SOURCE BOILER, WAER HEAER, EC. HEA RAP H APOLLO MIXING VALVE M C MIX EMP FIXURES HIGH EMP. FIXURES MVB SERIES MVD SERIES COLD WAER INLE YPICAL INSALLAION POIN OF USE - SANDARD FAUCE (WIH RECIRCULAION SYSEM) C H HEA SOURCE BOILER, WAER HEAER, EC. HEA RAP APOLLO MIXING VALVE AQUASA YPICAL INSALLAION POIN OF SOURCE (WIH RECIRCULAION SYSEM) YPICAL INSALLAION POIN OF USE - SENSOR FAUCE (WIH RECIRCULAION SYSEM) - DIRECION OF FLOW COLD WAER INLE H APOLLO MIXING VALVE C HIGH EMP. FIXURES - DIRECION OF FLOW COLD WAER INLE - HERMAL EXPANSION RELIEF VALVE OR ANK - PRESS. REDUCING VLV. C H HEA SOURCE M MIX EMP FIXURES - HERMAL EXPANSION RELIEF VALVE OR ANK - PRESS. REDUCING VLV. C H HEA SOURCE - CHECK VALVE - BALANCING VALVE - PUMP BOILER, WAER HEAER, EC. HEA RAP AQUASA - CHECK VALVE - BALANCING VALVE - PUMP BOILER, WAER HEAER, EC. HEA RAP APOLLO MIXING VALVE - EMPERAURE GAUGE - SHU-OFF VALVE RECIRCULAION LOOP - EMPERAURE GAUGE - SHU-OFF VALVE AQUASA V SERIES MVAH SERIES YPICAL INSALLAION HYDRONIC HEAING SYSEM (SINGLE LOOP) APOLLO MIXING VALVE MVE SERIES YPICAL INSALLAION EMERGENCY SYSEM (EYEWASH/FACEWASH) - DIRECION OF FLOW - HERMAL EXPANSION RELIEF VALVE OR ANK - PRESS. REDUCING VLV. - CHECK VALVE - PUMP - EMPERAURE GAUGE H HEA SOURCE BOILER, WAER HEAER, EC. H M C RADIAN FLOOR LOOPS COLD WAER INLE - DIRECION OF FLOW - HERMAL EXPANSION RELIEF VALVE OR ANK - PRESS. REDUCING VLV. - CHECK VALVE - BALANCING VALVE - PUMP COLD WAER INLE C H HEA SOURCE BOILER, WAER HEAER, EC. HEA RAP EYEWASH/FACEWASH FIXURE APOLLO MIXING VALVE - SHU-OFF VALVE - EMPERAURE GAUGE - SHU-OFF VALVE AQUASA DRAIN OHER APOLLO LIERAURE FOR YOUR SPECIFICAION LIBRARY Commercial Products Catalog Gate, Globe & Check Catalog Iron Gate, Globe & Check Catalog 18

19 MIXING ERMS, VALVES CONDIIONS & WARRANY INFORMAION WARRANY AND LIMIAIONS OF LIABILIY Conbraco Industries, Inc. warrants, to its initial purchaser only, that its products which are delivered to this initial purchaser will be of the kind described in the order or price list and will be free of defects in workmanship or material for a period of FIVE years from the date of delivery to you, our initial purchaser. his warranty applies to Apollo brand product with Made in the USA markings only. Should any failure to conform to this warranty appear within FIVE years after the date of the initial delivery to our initial purchaser, Conbraco will, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with Conbraco s recommendations and standard industry practice, correct such defects by suitable repair or replacement at Conbraco s own expense. APOLLO INERNAIONAL PRODUCS: Conbraco Industries, Inc. warrants its International products, to its initial purchaser only, that its international products which are delivered to this initial purchaser will be of the kind described in the order or price list and will be free of defects in workmanship or material for a period of WO years from the date of delivery to you, our initial purchaser. HIS WARRANY IS EXCLUSIVE AND IS IN LIEU OF ANY IMPLIED WARRANY OF MERCHANABILIY, FINESS FOR A PARICULAR PURPOSE OR OHER WARRANY OF QUALIY, WHEHER EXPRESSED OR IMPLIED, EXCEP HE WARRANY OF ILE AND AGAINS PAEN INFRINGEMEN. Correction of non-conformities, in the manner and for the period of time provided above, shall constitute fulfillment of all liabilities of Conbraco to our initial purchaser, with respect to the goods, whether based on contract, negligence, strict tort or otherwise. It is the intention of Conbraco Industries, Inc. that no warranty of any kind, whether expressed or implied shall pass through our initial purchaser to any other person or corporation. LIMIAION OF LIABILIY: Conbraco Industries, Inc. SHALL NO UNDER ANY CIRCUMSANCES BE LIABLE FOR SPECIAL OR CONSEQUENIAL DAMAGES SUCH AS, BU NO LIMIED O, DAMAGES OR O LOSS OF OHER PROPERY OR EQUIPMEN, LOSS OF PROFIS OR REVENUE, COS OF CAPIAL, COS OF PURCHASED OR REPLACEMEN GOODS, OR CLAIMS OF CUSOMERS OF OUR INIIAL PURCHASER. HE REMEDIES OF OUR INIIAL PURCHASER, AND ALL OHERS, SE FORH HEREIN, ARE EXCLUSIVE, AND HE LIABILIY OF CONBRACO WIH RESPEC O SAME SHALL NO, EXCEP AS EXPRESSLY PROVIDED HEREIN, EXCEED HE PRICE OF HE GOODS UPON WHICH SUCH LIABILIY IS BASED. * It is the end user s responsibility to confirm that items intended for use satisfy local codes and standards. for additional information, submittal sheets and manuals, visit 19

20 SALES & CUSOMER SERVICE: Phone: (704) Fax: (704) o find a Sales Rep in your area, visit our website. REGIONAL MANAGEMEN APOLLO VALVES, ELKHAR PRODUCS & LASCO FIINGS AREAS COVERED PHONE SENIOR MANAGEMEN Brian Ragone Senior VP - Sales & Marketing brian.ragone@conbraco.com Don Russell VP Sales - Commercial & Industrial don.russell@conbraco.com REGIONAL SALES DIRECORS COMMERCIAL & INDUSRIAL Mike Bedzyk Central/Northeast michael.bedzyk@conbraco.com Mitch Davis S. Central/Southeast mitch.davis@conbraco.com Phillip Merino West phillip.merino@conbraco.com REGIONAL SALES MANAGERS COMMERCIAL & INDUSRIAL Kevin Ashworth Southeast kevin.ashworth@conbraco.com Keith Baca Southeast keith.baca@conbraco.com Mike Blair Central mike.blair@conbraco.com Steve Brown Northwest steve.brown@conbraco.com Ken Copeland Southwest ken.copeland@conbraco.com Ben Lauletta Northeast ben.lauletta@conbraco.com Wesley Reinart S. Central wesley.reinart@conbraco.com INDUSRIAL MARKE MANAGERS Dave Eck Northeast david.eck@conbraco.com Ken Griffin Industrial & Commercial Valve rainer ken.griffin@conbraco.com Mark Sordelet Central mark.sordelet@conbraco.com Skip Wilson Northwest skip.wilson@conbraco.com BACKFLOW MARKE MANAGERS Pete Chapman National Manager pete.chapman@conbraco.com Cary Wiley East cary.wiley@conbraco.com APOLLOXPRESS MARKE MANAGERS John Rankel National Manager john.rankel@conbraco.com odd Green South Central todd.green@conbraco.com Brian Jennings North Central brian.jennings@conbraco.com Robert Purchia East robert.purchia@conbraco.com AREAS COVERED PHONE APOLLOPUSH MARKE MANAGERS George Dragosz Northeast george.dragosz@elkhartproducts.com Mark Schanback Southeast mark.schanback@conbraco.com Jeremy Small Central jeremy.small@conbraco.com Dean Weidlein West dean.weidlein@elkhartproducts.com WRO/CAS MARKE MANAGERS Cindy Goodwin National Manager cindy.goodwin@elkhartproducts.com CANADA Jeff Cooper General Manager jeff.cooper@conbraco.com Andy Fretz Commercial andy.fretz@conbraco.com Jim odman Industrial jim.todman@conbraco.com LASCO FIINGS REGIONAL SALES MANAGERS IRRIGAION David Beyer Northeast dbeyer@lascofittings.com Don Caver Central dcaver@lascofittings.com Ben Freeman Southeast bfreeman@lascofittings.com Bryan Jackman West bjackman@lascofittings.com Jimmy White National Sales Manager jwhite@lascofittings.com Rick Williamson Eastern Specifications Manager rwilliamson@lascofittings.com INERNAIONAL SALES MANAGERS Bill McNamara Director of International Sales bill.mcnamara@elkhartproducts.com JR Jefferson Central/South America & the Caribbean jr.jefferson@conbraco.com Brencliff Group Australia, New Zealand petermcl@brencliff.com Pegler Yorkshire United Kingdom adrian.byrne@conbraco.com Pegler Yorkshire Mid East Middle East/India peter.pydubai@gmail.com Europe/Africa/Israel customersupport@conbraco.com current as of 7/20/15 For more information about Apollo Valves, Elkhart Products Corporation, and our family of AMERICAN MADE products, contact: PHBRMIX 1/12 5,000 CG (REV )

See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section.

See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section. See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section. MIXING VALVES Hydronic Tempering Valves TV (34-200) SERIES MIXING VALVES These dependable thermostatic

More information

CERT. TO ASSE STD 1016 AND 1017 1016 AND 1017 1016 AND 1017 WT. LBS.

CERT. TO ASSE STD 1016 AND 1017 1016 AND 1017 1016 AND 1017 WT. LBS. SUBMITTAL DATA/INSTRUCTION SHEET SD/IS 150 EFFECTIVE September 004 Supercedes March 3, 004 AM-1 SERIES TM ANTI-SCALD PROPORTIONAL THERMOSTATIC MIXING DIVERTING VALVE PATENTED, WITH DUAL ASSE 10 CERTIFICATION,

More information

WATER PRESSURE REDUCING VALVES

WATER PRESSURE REDUCING VALVES MADE IN THE USA WATER PRESSURE REDUCING VALVES TABLE OF CONTENTS PRODUCT PAGE How Pressure Reducing Valves Work 3 36 Series 4 36C Series 6 36H Series 8 AUTOMATIC PRESSURE REDUCTION Pressure reducing valves

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV MODEL EMV Emergency Safety Shower Water Heater Tepid Water For Emergency Safety Shower/Eyewash Stations Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon

More information

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

TANKLESS WATER HEATER INSTALLATION DIAGRAMS TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water

More information

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

Electronic Wallmount Faucet 1500T4 & 1501T4 Series Electronic Wallmount Faucet 1500T4 & 1501T4 Series Specification: (example) Battery (4 C cell) or Hardwire (24 VAC) infrared electronic handwash system H 2OPTICS technology no external adjustments required

More information

Commercial Electric Water Heater

Commercial Electric Water Heater Commercial Electric Water Heater Provides Tepid Water For Emergency Fixtures Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust

More information

Domestic Hot Water Systems and Plumbing Products

Domestic Hot Water Systems and Plumbing Products Domestic Hot Systems and Plumbing Products Taco Catalog #100-117 Effective Date: 09/02/15 Supersedes: 06/22/15 Printed in USA Domestic Hot Recirculation Taco Domestic Hot Plumbing Products Since 1920 Taco

More information

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International Presentation Overview Water Heater Piping Strategies How to size a water heater?

More information

In-Line Air Separators

In-Line Air Separators Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI

More information

Thermostatic Mixing Valves

Thermostatic Mixing Valves Thermostatic Mixing Valves Reliable, ASSE-listed valves from a recognized leader in flow-control products W atts.com The Trusted Choice for Thermostatic Mixing Valves Watts provides a complete thermostatic

More information

HL Series - Commercial Heaters Tankless Water Heating Solutions

HL Series - Commercial Heaters Tankless Water Heating Solutions HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage

More information

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS HEAT-FLO HOT WATER STORAGE / BOOSTER TANKS MODELS 30-ST, 40-ST, 40L-ST, 60-ST, 60L-ST, 80-ST, 115-ST, 80-ST-C, 115-ST-C FOR SINGLE TANK INSTALLATIONS For

More information

PLUMBING SUBMITTAL 22 33 13

PLUMBING SUBMITTAL 22 33 13 PLUMBING SUBMITTAL 22 33 13 ACADEMIC BUILDING & PATRIOT S CASA TEXAS A&M UNIVERSITY - SAN ANTONIO, TX NO. 25-3122, VAC NO. 39019 OWNER: ARCHITECT: MEP ENGINEER: GENERAL CONTRACTOR: PLUMBING CONTRACTOR:

More information

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER 1.800.591.9360 TECHNICAL ASSISTANCE FAX: 1.626.855.4894

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER 1.800.591.9360 TECHNICAL ASSISTANCE FAX: 1.626.855.4894 ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 9744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FREEZE RESISTANT WALL MOUNTED EMERGENCY EYEWASH

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

Effective Date: January 1, 2009

Effective Date: January 1, 2009 Lawler Manufacturing 2009 List Price Sheet (valid in SK, MB, ON and QC only) Effective Date: January, 2009 c=00 m=72 y=0 b=6 For more information contact www.dobbinsales.com Go to www.lawlervalve.com to

More information

PLBG/GAS SAFETY Information Bulletin

PLBG/GAS SAFETY Information Bulletin PLBG/GAS SAFETY Information Bulletin November 2012 P/G-08-02-PLBG/GAS [Rev 3] Page 1 of 11 SUBJECT: REQUIREMENTS FOR COMBINATION HEATING SYSTEMS: DUAL PURPOSE WATER (POTABLE) HEATER (COMBO UNIT) Safety

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

Element D Services Plumbing

Element D Services Plumbing PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses domestic cold, hot and hot water return distribution systems within and to five feet beyond building perimeter. PART 2 - DESIGN CRITERIA 2.01 GENERAL

More information

Installation & Operation Manual Models: STU150-940

Installation & Operation Manual Models: STU150-940 STU-I-O Rev B Installation & Operation Manual Models: STU150-940 IMG00044 LOW LEAD CONTENT WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions

More information

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Water Circulation Pumps & Circulators Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide Taco Catalog # 100-41 Supersedes: 08/07/15 Effective Date: 09/01/15 Printed in

More information

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m. Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m. Safety First! How to Specify Emergency Showers and Eyewashes Presented by Mike Adkins, Guardian Equipment. ASPE

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

Backflow Bulletin #1

Backflow Bulletin #1 Backflow Bulletin #1 FIRE PROTECTION SYSTEMS Chemicals in the System Anti-Freeze, Foam, Corrosion Inhibitors, etc. Chemicals in the System Glycerin Glycerin or similar food-grade non-toxic additive Siamese

More information

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608

OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions

More information

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version) BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version) Bradley Halo Emergency Plumbing Fixtures are a new generation in safety equipment, featuring separate supply and waste piping to eye/face wash,

More information

What to Expect From the Examination. How to Study the Plumbing Codes

What to Expect From the Examination. How to Study the Plumbing Codes Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for

More information

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities. SECTION 224500 - EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No: 0816407 Rev. 4 (07/12)

More information

Pressure Drop Basics & Valve Sizing

Pressure Drop Basics & Valve Sizing Pressure Drop Basics & Valve Sizing What is Pressure Drop? The difference in pressure between two points in a system, caused by resistance to flow. What Pressure Drop is Not? Pressure drop is pressure

More information

SECTION 22000. Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

SECTION 22000. Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters) SECTION 22000 Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters) PART I - GENERAL A. Description This section includes requirements for materials for installation of Hot

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

Indirect Fired Water Heaters

Indirect Fired Water Heaters Indirect Fired Water Heaters Installation and Operating Manual C US Models: SST150-40 SST250-65 SST300-80 SST450-119 CAUTION The heat transfer medium must be water or other nontoxic fluid having a toxicity

More information

NAVIEN AMERICA INC. 17855 FITCH AVENUE

NAVIEN AMERICA INC. 17855 FITCH AVENUE Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Installation & Operation Manual Models: SIT030 - SIT119

Installation & Operation Manual Models: SIT030 - SIT119 SIT-I-O Rev K Installation & Operation Manual Models: SIT030 - SIT119 CAUTION: The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1, as listed in Clinical

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

77 ILLINOIS ADMINISTRATIVE CODE, PART 890 (NEW) ILLINOIS PLUMBING CODE (02/04) SUBPART I: WATER SUPPLY AND DISTRIBUTION

77 ILLINOIS ADMINISTRATIVE CODE, PART 890 (NEW) ILLINOIS PLUMBING CODE (02/04) SUBPART I: WATER SUPPLY AND DISTRIBUTION SUBPART I: WATER SUPPLY AND DISTRIBUTION Section 890.1110 Quality of Water Supply All premises intended for human habitation or occupancy shall be provided with a potable water supply. The potable water

More information

Installation and Operating Instruction Manual

Installation and Operating Instruction Manual Electric Mini Tank Water Heaters CMT-1.3 CMT-2.5 CMT-4.0 CMT-ST70 Tempering valve Optionally available Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General

More information

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,

More information

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Instruction Sheet 102-140 Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Plant I.D. 001-1024 EFFECTIVE: November

More information

What is Thermal Expansion?

What is Thermal Expansion? What is Thermal Expansion? When water is heated it expands. For example, water heated from 90ºF to a thermostat setting of 140ºF in a 40 gallon hot water heater will expand by almost one-half gallon. This

More information

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual Mini Tank Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General Information 3/6 Technical

More information

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS D E S I G N E D T O L E A D Mega-Stor TM Stainless Steel, Indirect Water Heaters INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS CAUTION 1. having a toxicity rating or Class

More information

FIRING RANGE PHASE 1 DESIGN 224500-1

FIRING RANGE PHASE 1 DESIGN 224500-1 FIRING RANGE PHASE 1 DESIGN 224500-1 SECTION 224500 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

15430 SAFETY SHOWERS AND EYEWASHES

15430 SAFETY SHOWERS AND EYEWASHES 15430 SAFETY SHOWERS AND EYEWASHES PART 1: GENERAL 1.01 RELATED SECTIONS 01005 - ENVIRONMENTAL HEALTH 11600 LABORATORY EQUIPMENT 15020 - LABORATORIES 15130 - PIPING SPECIALITES 15400 - PLUMBING 15420 -

More information

Electric Mini Tank Water Heaters WM-2.5 & WM-4.0

Electric Mini Tank Water Heaters WM-2.5 & WM-4.0 Electric Mini Tank Water Heaters WM-2.5 & WM-4.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 2 Technical Data 3-4 General Information 5 Technical Description

More information

GOLD Plus 30/40/60/80

GOLD Plus 30/40/60/80 PLUS Line Indirect-Fired Water Heaters Series 3 Manual Installation Startup Maintenance Parts PLUS 100/110/119 GOLD Plus 30/40/60/80 Plus 40/60/80 This manual must only be used by a qualified heating installer/service

More information

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination

More information

Installation, Maintenance, & Repair Series 4000B/LF4000B

Installation, Maintenance, & Repair Series 4000B/LF4000B Installation, Maintenance, & Repair Series 4000B/LF4000B Reduced Pressure Zone Assemblies Sizes: 1 2" 2" (15 50mm) RP/IS-A-4000B 4000B/LF4000B Size: 3 /4"! WARNING Testing Read this Manual BEFORE using

More information

SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE Eemax Inc., 353 Christian Street, Oxford, CT 06478 1 E ema X SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE WARNING

More information

Automatic control equipment for HVAC systems

Automatic control equipment for HVAC systems Automatic control equipment for HVAC systems Products for domestic and industrial installations In buildings, the main aim of the installations is to guarantee and maintain a comfortable ambient. Watts

More information

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations

More information

DIVERSIFIED HEAT TRANSFER, INC. 1710 Flushing Avenue Ridgewood, NY 11385 Phone: 718-386-6666 / 800-221-1522 Fax: 718-386-7809 www.dhtnet.

DIVERSIFIED HEAT TRANSFER, INC. 1710 Flushing Avenue Ridgewood, NY 11385 Phone: 718-386-6666 / 800-221-1522 Fax: 718-386-7809 www.dhtnet. Installation & Operating Instructions INDIRECT WATER HEATERS TO THE INSTALLER: This manual is the property of the owner and must be affixed near the water heater for future reference. TO THE OWNER: This

More information

SHOWERS 85-100 SHOWERS

SHOWERS 85-100 SHOWERS SHOWERS 85-100 85 SHOWERS SHOWER HEADS 87 NEPTUNE 89 SHOWER PANEL SERIES PERFECT TIME SHOWER PANEL SERIES 91 NEPTUNE 1042T 93 PERFECT TIME 1042T 94 NEPTUNE MEDICAL 95 TOUCH SH 1000T 96 NEPTUNE 1032 97

More information

Tepid Water Solutions for you and your customers

Tepid Water Solutions for you and your customers www.tepid.com Tepid Water Solutions for you and your customers Thank you for your interest in the Stingray product line. This brochure is a representation of our capabilities, and we encourage you to contact

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

What you can expect from your Solar Hot Water System

What you can expect from your Solar Hot Water System Owner s Manual Your Solar Hot Water System Thank you for your investment in the FAFCO Solar Hot Water System. Since 1969 our goal has been to design, test, and produce solar heating systems that save you

More information

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING WARRANTY 1 PACKING LIST DESCRIPTION MODEL NUMBER - PANEL HOUSING 88062

More information

ASSE 1016, 1069 & 1070

ASSE 1016, 1069 & 1070 ASSE 1016, 1069 & 1070 ASSE 1016-2005 Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations Intended for wall-mounted showers and tub/showers Bather or bather s attendant has

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

Light Duty Commercial Electric Water Heater

Light Duty Commercial Electric Water Heater Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and

More information

B. Shop Drawings: Diagram power, signal, and control wiring.

B. Shop Drawings: Diagram power, signal, and control wiring. SECTION 224500 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Emergency showers. 2. Eyewash equipment. 3. Eye/face wash equipment. 4. Combination units. 5. Water-tempering equipment. 1.2 SUBMITTALS

More information

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000 Multi-Pure Whole House Water Treatment System Installation, Operation and Maintenance Manual Multi-Pure Model TO15000 Warning Please read manual carefully before proceeding with installation. It is recommended

More information

Nordic Heat Pump Product Guide

Nordic Heat Pump Product Guide Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps

More information

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities. SECTION 224500 - EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Installation Instructions

Installation Instructions PUSH Installation Instructions A DA C O M PLIA NT shown with optional Bradley 90-75 faucet Front-Mounted Barrier Free Rectangular Bowl Stainless Steel Lav Table of Contents Pre-Installation Information...........2

More information

Tempra / DHC-E. Simply the Best 800.582.8423. The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control

Tempra / DHC-E. Simply the Best 800.582.8423. The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control ENGINEERING EXCELLENCE Simply the Best The Finest Tankless Electric Water Heater Available! Tempra / DHC-E Featuring Advanced Microprocessor Control Outperforms Bulky Hot Water Tanks Reduces Hot Water

More information

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION 220519 - THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION 220519 - THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling October 2014 contents General Information

More information

INSTALLATION INSTRUCTIONS AND HOMEOWNER MANUAL

INSTALLATION INSTRUCTIONS AND HOMEOWNER MANUAL INSTALLATION INSTRUCTIONS AND HOMEOWNER MANUAL MODELS: AH27, AH24, AH21, AH18, AH16, AH14, & AH 11 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic

More information

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number: Seaward Products WATER HEATERS OWNER S MANUAL Serial Number: IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions to reduce the risk of fire, electrical shock,

More information

heat transfer solutions Steam to Water Heat Transfer Packages for Domestic Hot Water

heat transfer solutions Steam to Water Heat Transfer Packages for Domestic Hot Water heat transfer solutions Steam to Water Heat Transfer Packages for Domestic Hot Water Steam to Water Heat Transfer Steam to Water Heat Transfer Packages for Domestic Hot Water Spirax Sarco offers a complete

More information

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities. SECTION 22 45 00 - (ADD#2) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description Style 07 Zero Flex Rigid Coupling The unique angled pad design adjusts to standard pipe tolerances to positively clamp the pipe to resist flexural and torsional loads. Working pressures are based on standard

More information

DECONTAMINATION PRODUCTS

DECONTAMINATION PRODUCTS DECONTAMINATION PRODUCTS AXION MSR TM EYE/FACE WASH UNITS SHOWERS :: COMBINATION UNITS This catalog represents a snapshot of the emergency response equipment that Haws offers. For more details and a comprehensive

More information

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

DOUBLE SEAT BRONZE BODY HIGH CAPACITY PS593DB HEAVY DUTY BRONZE GLOBE CONTROL VALVES DB DOUBLE SEAT BRONZE BODY HIGH CAPACITY 1, 1-1/4, 1-1/2, and 2 Union Ends ANSI Class 250 Body Rating ANSI Class II Close off Bronze or Stainless Steel Trim

More information

1805 Series Relief Valves

1805 Series Relief Valves October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications

More information

Commercial Electric Water Heater

Commercial Electric Water Heater MODEL SE Commercial Electric Water Heater 6-120 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction Hydrastone cement lining

More information

Slide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation.

Slide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation. Slide 1 Thank you for attending the session on Hot Water Re-Circulation. Hot Water Re-Circulation National Conference Center Lansdowne, VA March 25 th & 26 th, 2010 Slide 2 AGENDA Water Waste Statistics

More information

When Should Examination Preparation Begin?

When Should Examination Preparation Begin? Texas State Board of Plumbing Examiners Tradesman Plumber-Limited Licensee Examination Review Course The following Examination Review Course is designed to assist a registered Plumber s Apprentice in preparing

More information

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS TS-250 Rev. 0-00-12-07 Refined Fuels PD Meters Size 2 Type 4-MT & 4D-MT 2 PETROLEUM AND LP-GAS TANK TRUCK METERS 2 4-MT with Air Release, Strainer, Printing Register and Preset Valve 2 4D-MT with Vapor

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always

More information

Installation Instructions / Warranty

Installation Instructions / Warranty Installation Instructions / Warranty Vertical Spray Bidet Fitting Rough 1322X181 Citterio 39224xx0 Citterio 39225xx0 Starck 10220xx0 Steel 35220800 Uno 38220xx0 Terrano 37224xx0 Terrano 37225xx0 Carlton

More information

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

INDIRECT WATER HEATER. Installation and Operating Instruction Manual INDIRECT WATER HEATER Installation and Operating Instruction Manual Maximum supply temperature to heat exchanger must not exceed 180 F (82 C). Safety Warning: Indirect water heaters are heat-producing

More information

SIZING OF WATER PIPING SYSTEM

SIZING OF WATER PIPING SYSTEM SIZING OF WATER PIPING SYSTEM SECTION E101 GENERAL E101.1 Scope. E101.1.1 This appendix outlines two procedures for sizing a water piping system (see Sections E103.3 and E201.1). The design procedures

More information

THERM Tankless Water Heaters. Applications Manual

THERM Tankless Water Heaters. Applications Manual THERM Tankless Water Heaters Applications Manual 2 THERM Tankless Water Heater Applications Manual THERM Tankless Water Heater Applications Manual 3 Table of Contents 1 Introduction 4 2 Bosch THERM Model

More information

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL MODELS: HA018240 HA024240 HA027240 HA036240 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety

More information

Heating Water by Direct Steam Injection

Heating Water by Direct Steam Injection Heating Water by Direct Steam Injection Producing hot water by direct steam injection provides a solution where large volumes of hot water at precise temperatures are required, and where energy and space

More information

Solar Skies Stainless Tank Series Water Heater

Solar Skies Stainless Tank Series Water Heater Solar Skies Stainless Tank Series Water Heater Installation Operation Maintenance Solar Skies Stainless Tank CD1051A.doc Last Revision: 1/31/2011 1 CONTENTS Part 1 Product and Safety Information.....................................

More information

Plumbing Identification and Damage Assessment Guide

Plumbing Identification and Damage Assessment Guide Plumbing Identification and Damage Assessment Guide *Please note that not all systems will be represented exactly by these diagrams and photos. As a vendor, it is required that you familiar yourself with

More information

Arapahoe County Residential Water Heater Installation and Inspection Guide

Arapahoe County Residential Water Heater Installation and Inspection Guide Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however

More information

Trin & Stor Model Numbers: ST Series Version Date: 2012-04-19

Trin & Stor Model Numbers: ST Series Version Date: 2012-04-19 Trin & Stor Model Numbers: ST Series Version Date: 2012-04-19 NEW PRODUCT LINE Storage Tanks Stainless Steel Tank TPI Thermostat STORAGE TANK INSTALLATION AND OPERATION INSTRUCTIONS Storage companion to

More information