7210-SAS D OS 3.0R9 SOFTWARE RELEASE NOTES
|
|
|
- Nathan Eaton
- 9 years ago
- Views:
Transcription
1 7210-SAS D OS 3.0R9 MARCH 5, SAS D OS 3.0R9 SOFTWARE RELEASE NOTES These release notes are for Release 3.0R9 of the 7210-SAS D OS software for 7210 SAS D devices. RELEASE NOTE ORGANIZATION The following are the major topics covered in these Release Notes: Standard Software Upgrade Procedure on page 2 Resolved Issues on page 4 New Features on page 6 Enhancements on page 11 Known Limitations on page 12 Known Issues on page 15 * V3.0.R9* Alcatel-Lucent Page V3.0.R9
2 7210-SAS D OS 3.0R9 Software Release Notes SOFTWARE UPGRADE PROCEDURES The following sections contain information for upgrading to the 3.0R9 software version. In particular, there are sections that describe the following: Standard Software Upgrade Procedure Procedure for performing a standard, service-affecting upgrade. STANDARD SOFTWARE UPGRADE PROCEDURE This section describes the standard software upgrade procedure which is service-affecting: Each software release includes a boot loader (boot.tim) and the software image (both.tim). The boot loader initiates the loading of the 7210 SAS OS image based on the boot options file (bof.cfg) settings. The following steps describe the software upgrade process: Step 1. Backup existing images and configuration files New software loads may make modifications to the configuration file which are not compatible with older versions of the software. Note: Alcatel-Lucent recommends making backup copies of the BOOT loader (boot.tim), software image (both.tim) and configuration files, should reverting to the old version of the software be required. Step 2. Copy 7210 SAS D images to cf1: The 7210 SAS D image files both.tim must be copied to the cf1: device on the 7210 SAS D node. It is a best practice to place all the image files for a given release in an appropriately named subdirectory out of the root. For example: cf1:\3.0r9. Copying the boot.tim and other files of a given release to a separate subdirectory ensures that all files that are available for the release must be downgrading the software version that is necessary. Note: SAS-D of 64MB flash (part numbers 3HE05676AAAA01, 3HE05676ABAA01, 3HE05677AAAA01, 3HE05677ABAA01 and 3HE06537AAAA01), flash can accommodate one set of boot.tim and both.tim files. It is required to overwrite existing files with new files in cf1.with Enhanced SAS-D (SAS-D with 128MB flash) supported from 3.0R9, more than one set of boot.tim and both.tim files can be stored on flash. Step 3. Copy boot.tim to the root directory on cf1: The BOOT Loader file is named boot.tim. This file must be copied to the root directory of the cf1: device. Page 2 Alcatel-Lucent
3 7210 SAS-D OS 3.0R9 Software Release Notes Note: If it is not possible to overwrite cf1:\boot.tim file, Change the cf1:\boot.tim attributes using file attrib -r cf1:\boot.tim command. Step 4. Step 5. Step 6. Modify the boot options file to boot the new Image. The Boot Options File (bof.cfg) is read by the BOOT Loader and indicates primary, secondary and tertiary locations for the image file. The bof.cfg should be modified as appropriate to point to the image file for the release to be loaded. Use the bof save command to save the Boot Options File modifications. When upgrading to 3.0R9, execute the admin reboot upgrade command. Note that, executing 'admin reboot upgrade' command system will upgrade the bootrom if required. Allow the boot sequence to complete and verify that the card comes up. Upgrade the Golden BOOT Loader (only if all of the above steps were successful). After successfully booting of the new version of 7210 SAS D image, upgrade the golden boot loader by executing the admin update-golden-bootstrap cf1:/boot.tim command. Alcatel-Lucent Page 3
4 7210-SAS D OS 3.0R9 Software Release Notes RESOLVED ISSUES RESOLVED IN R3.0R9 The following are specific technical issues that have been resolved in Release 3.0_R9 of SAS D OS. In previous releases, when snooping is enabled on an access-uplink port, learned multicast traffic impacted the unicast meter instead of multicast meter. This issue has been resolved. [127139] RESOLVED IN R3.0R8 The following are specific technical issues that have been resolved in Release 3.0_R8 of SAS D OS. In previous releases, when the remote MEP was deleted or remote port/sap was shut down, "show eth-cfm mep", R-mepId Rx CC showed "True", but HighestDefect showed "defremoteccm". In 3.0R8, R-mepId Rx CC shows the correct sate. [124981] In previous releases, TACACS authenticated CLI users experienced slow response in some cases. This issue has been resolved.[122799] RESOLVED IN R3.0R6 The following are specific technical issues that have been resolved in Release 3.0_R6 of SAS D OS. In previous release, Delay computed by Y DM OAM tool shows variations in results. In this release issue has been fixed. For 1-DM to provide accurate results, it is required to have NTP clocks on the nodes to be synchronised.[119670] RESOLVED IN R3.0R5 The following are specific technical issues that have been resolved in Release 3.0_R5 of SAS D OS. CLI Creating a user with all the SNMP OIDs are sent in one PDU, and executing CLI "admin display-config" and "admin tech-support", or "configure system security / info", hangs the CLI session. This issue is resolved now. [117416] After a few hours, the 7210 would fail to sync the system time with an NTP server. In this release, the 7210 SAS-D syncs with the Server. This issue was observed with 3.0R4 [118779] A CLI session might have remained logged in beyond its idle-timeout period if the user improperly terminated the CLI session by closing the session window while a multi-output CLI command (that is, the "monitor" command) was in progress. This issue has been resolved.[111704] SERVICES If 2 saps are configured on a port, where one sap has a single level mep and other sap has multiple levels of mep, eth-cfm was not converging. Page 4 Alcatel-Lucent
5 7210 SAS-D OS 3.0R9 Software Release Notes For example, if sap-1 is configured with mep level 1, and sap-2 is configured with mep level 1 and 4, sap-1 level 1 and sap-2 level 4 meps will not converge. Workaround: If sap-1 and sap-2 are configured with both mep level 1 and 4, eth-cfm will converge. This issue has been resolved. [114386] Vlan Tag was not getting changed as per egress encap when port 1/1/7 and lag-1 were part of the same service. Similar issue was seen with combination used in same service (Port 1/1/8 and lag-2), ( Port 1/1/9 and lag-3) and (Port 1/1/10 and lag-4). This issue has been resolved. [116731] SYSTEM Fiber SFP 100FX LX or BX type is supported. [114461] Alcatel-Lucent Page 5
6 7210-SAS D OS 3.0R9 Software Release Notes NEW FEATURES RELEASE 3.0R9 The following describe features added to the 7210 SAS-D OS release 3.0R9. ENHANCEMENTS TO 7210 SAS-D PLATFORM Release 3.0R9 introduces enhanced 7210 SAS-D platform part number. The following are the part numbers of the new platform: - 3HE05676ACAA SAS-D 6F4T ETR AC - 3HE05676ADAA SAS-D 6F4T ETR -48V DC - 3HE05677ACAA SAS-D 6F4T AC - 3HE05677ADAA SAS-D 6F4T -48V DC - 3HE06537ABAA SAS-D 6F4T ETR +24V DC The following enhancements are added to the 7210 SAD-D platform: The flash size is doubled to 128MB. The increase in size of the flash allows the operator to store multiple copies of the image on flash allowing a smoother software upgrade. External Backup power supply presence information is added this enhancement is applicable only to 7210 SAS-D ETR. The system can detect an external backup power supply in use and provide LED on the front panel, which provides visual indication of the power supply status. The system raises an alarm if either the external power supply fails or if the in-built power supply fails. The system cannot detect the type of the external backup supply and does not support power source failure. It can also be said that the system does not provide the capability to detect failure of power feeds. Bigger heat sinks have been added for SFP cages, processor and network processor. These heat sinks enhance cooling of the device in particular when GPON/EPON SFPs are used. Temperature gauge is located at better position. This improves the level of accuracy with regard to the measurement of chassis temperature. Console ports are enhanced to make them compatible with a wider variety of available console cables. Note: The enhanced 7210 SAS-D can boot release 3.0R9 and later images of 3.0 releases. Older images (that is, release 3.0R8 and older) must not be used with the new devices. Use of old images can result in loss of management connectivity and continuous reboot. In such case, user needs console access to manually load proper image. The older 7210 SAS-D (ones with 64MB flash) can use any image, release 3.0R9, prior and later. All new devices will be shipped with the latest bootrom. RELEASE 3.0R8 There are no new features added to the 7210 SAS-D OS release 3.0R8. Page 6 Alcatel-Lucent
7 7210 SAS-D OS 3.0R9 Software Release Notes RELEASE 3.0R7 There are no new features added to the 7210 SAS-D OS release 3.0R7. RELEASE 3.0R6 The following describe features added to the 7210 SAS-D OS release 3.0R6. LINE TIMING OF ETHERNET PORTS USING SYNCE WITH SSM SUPPORT In this release, 7210 SAS-D ETR provides support for Synchronous Status Message (SSM) (also known as ESMC) for Synchronous Ethernet. SSM provides a mechanism to allow the synchronization distribution network to both determine the quality level of the clock for a given synchronisation trail and to allow a network element to select the best of multiple input synchronization trails. Synchronization Status messages have been defined for various transport protocols including SONET/SDH, T1/E1, and synchronous Ethernet, for interaction with office clocks, such as BITS or SSUs and embedded network element clocks. SSM allows equipment to autonomously provision and reconfigure (by reference switching) their synchronization references, while helping to avoid the creation of timing loops. These messages are particularly useful to allow synchronization reconfigurations when timing is distributed in both directions around a ring. In Synchronous Ethernet, SSM uses an Ethernet OAM PDU that uses the slow protocol subtype. For a complete description of the format and processing, see ITU-T G Copper interfaces can be used only for timing distribution. They are not recommended for use as timing references. RELEASE 3.0R5 The following describe features added to the 7210 SAS-D OS release 3.0R SAS-D ETR This release introduces support for Extended Temperature Range (ETR) variant of 7210 SAS-D (viz SAS-D 6F4T ETR). The 7210 SAS-D ETR variants support extended temperature range (that is, -40C 65C) and provides an onboard stratum 3 Oscillator for synchronisation. These features enable operators to use this node for outdoor mobile backhaul applications SAS-D ETR will be available in three options (power supply being different) - DC unit supporting +48V DC power supply with an external backup power supply. - DC unit supporting +24V power supply with an external backup power supply. - AC unit with an external backup supply. The external back power supply is also available in three variants. It available as an AC variant, +24V DC variant, and -48V DC variant. This allows users a choice based on their deployment requirements. Additionally, users can use any variant of external backup power supply with any variant of the 7210 SAS-D ETR node. Alcatel-Lucent Page 7
8 7210-SAS D OS 3.0R9 Software Release Notes In this release, 7210 SAS-D ETR variant supports all the features supported in the standard variant (non-etr variant). MULTIPLE SPANNING TREE (MSTP) The Multiple Spanning Tree Protocol (MSTP) extends the concept of the IEEE 802.1w Rapid Spanning Tree Protocol (RSTP) by allowing grouping and associating VLANs to Multiple Spanning Tree Instances (MSTI). Each MSTI can have its own topology, enabling load balancing by providing multiple forwarding paths. At the same time, the number of STP instances running in the network is significantly reduced as compared to Per VLAN STP (PVST) mode of operation. Network fault tolerance is also improved because a failure in one instance (forwarding path) does not affect other instances. The 7210 SAS implementation of Management VPLS (mvpls) is used to group different VPLS instances under single RSTP instance. Introducing MSTP into the mvpls allows interoperating with traditional Layer 2 switches in access network and provides an effective solution for dual homing of many business Layer 2 VPNs into a provider network. IGMP SNOOPING In 3.0R5, 7210 SAS D introduces IGMP snooping in a VPLS service support SAS-D supports IGMPv1, IGMPv2 and IGMPv3. IGMP snooping allows the system to distribute multicast streams to only interested receivers in a Layer 2/bridging domain. G.8032 In this release, G.8032 is supported in 7210 SAS-D. ITU-T G.8032 specification - version 1defines protocol mechanisms to provide ethernet ring protection to enable deployment of resilient Ethernet Layer 2 networks. G.8032(ETH-ring) is built on Ethernet OAM and is also referred to as Ring Automatic Protection Switching (R-APS). ETH-rings are supported only on VPLS access and access uplink SAPs (for VPLS Service). VPLS services supporting Eth-rings enables rings for core network or access network resiliency. ETH-ring multi-homing into other ETH-rings or VPLS PEs is not supported in the current release. ETH-rings offer fast resiliency for Ethernet services leveraging ring topologies for any single link or node failure. By configuring multiple ETH-rings instances on the same physical topology, G.8032 can utilize all link resources in a ring. Y.1731 Y.1731 is defined by ITU-T. It is built on top of the IEEE 802.1ag, but it has more functionalities compared to the former, such as AIS, performance monitoring, etc. In this release, the following Y.1731 functionalities are supported: - ETH-CCM - ETH-LB - ETH-LT - ETH-RDI - ETH-AIS - ETH-TST - ETH-DM two-way delay measurements. For 2-way-delay-measurement, Rx as well as Tx timestamps added by hardware. Page 8 Alcatel-Lucent
9 7210 SAS-D OS 3.0R9 Software Release Notes SYNCHRONOUS ETHERNET In this release, line timing using Synchronous Ethernet (synce) is available only on the 7210 SAS-D ETR. SyncE is supported over for both fiber SFP and fixed copper Ethernet interfaces. The SFP interfaces can be used both as a line timing source to synchronize the system clock to a reference network clock and for line timing distribution allowing operators to use the node in the network synchronization hierarchy. The copper interfaces are recommended for use only in line timing distribution. The node allows for selection of an Ethernet port as a candidate for timing reference. The timing recovered from the configured reference is used to time the system. Additionally, the recovered timing is distributed to other ethernet ports. SyncE SSM/ESMC support is not available in this release. For more details please refer to the 7210 SAS-D/E Systems Basic User guide and 7210 SAS-D/E Interfaces User guide. IP INTERFACES IN VPLS SERVICE The 7210 SAS-D supports IP interfaces in a VPLS service. IP interfaces in VPLS services provide only a host IP interface (non-routable). Only IP ping and IP traceroute applications are supported for this IP interface. It is primarily designed for use to verify service availability during service activation and/or during normal service use by using IP ping utility. POINT INTERNAL LOOPBACK With this release, 7210 SAS-D supports port internal loopback feature. This feature enables an internal PHY/MAC loopback. With the internal loopback configuration, packets that egress out of that port (or SAPs created on that port) are looped back into the node instead of being transmitted on to the line/wire. The packet that ingress the system after the loop back, are mapped to the same SAP on which the packet was sent out, as if its being received from another device connected to the port and is processed as per the service configuration for that SAP. A internal loopback on the port is expected to be used with a external third-party Ethernet test device. They can be used to diagnose problems with the service provisioning or for testing end-to-end performance metrics for the service. It is highly recommended that this command be used only for testing a VLL service. The source/destination MAC address swap is not done. Hence, its use in a VPLS service will potentially lead to rapid MAC address movement from one port to another. It is not required to insert an SFP/XFP into the device OR plugin the ethernet cable in case of fixed copper ports for the loopback to be functional. This command affects all the services provisioned on the port, since packets are looped back and sent out back to the sender. It is expected to be used only with a VLL service. It is recommended to turn off Layer 2 and IP control protocols (like xstp, LACP, EFM, 802.1x, LLDP, OSPF, etc.) on the device where the loopback command is executed and also on the peer device to avoid unnecessary protocol behavior (e.g. protocol flaps due to time-out, etc.). RELEASE 3.0R4 The following describe features added to the 7210 SAS-D OS release 3.0R4. With 3.0R4 release, support for 7210 SAS-D 6F4T platform operating in standard temperature range is available SAS-D is an ethernet demarcation and backhaul unit with support for 4 x 10/100/100 Base-T ports and 6 x 100/1000 SFP ports, for use typically as a customer Alcatel-Lucent Page 9
10 7210-SAS D OS 3.0R9 Software Release Notes premise unit (CPE). It supports line-rate switching on all the ports. It is a service-aware Ethernet switch with support for QinQ layer-2 uplinks. It has an single integrated power supply and supports fan-less operation. The following are some of the major features supported in 7210 SAS-D: VPLS and VLL services IES service only for use in inband management of the device QoS (SAP ingress Qos policies with hierarchical metering, Access Egress QoS policies per port, Access uplink ingress and egress policies per port, etc.) Accounting policies ACLs (MAC and IP criteria) LAG (with support for active/standby to allow for being a MC-LAG client) STP/RSTP and mvpls/rstp LLDP EFM with dying gasp support CFM The following features are NOT available in the current release: IGMP Snooping Y.1731 G.8032 VPLS IP interface Page 10 Alcatel-Lucent
11 7210 SAS-D OS 3.0R9 Software Release Notes ENHANCEMENTS RELEASE 3.0R9 There are no new enhancements added to 3.0 R9 of the 7210 SAS-D OS. Alcatel-Lucent Page 11
12 7210-SAS D OS 3.0R9 Software Release Notes KNOWN LIMITATIONS On the 7210 SAS-D platform, even if a SAP is administratively shutdown, the hardware state machine receives and processes the CCM packets sent by remote peers and the CFM MEP remains up and shows no CCM defect.[126719] The doubly tagged packet ingress on Q.* sap egresses with 3 tags on the Q1.Q2 sap. Such packet not identified as an IP packet as a result will not match the IP ACL on egress. [112850] Ethernet ports that use dual-rate fiber SFPs cannot participate in a Synchronous Ethernet Network. Applying the command "debug sync-if-timing" on a second qualified reference has no effect. SyncE Reference switch is based on LOS and not based on signal degradation. Up to 10 Uplink access SAPs can be ingress mirrored. [114247] After reboot for about 15 minutes, card temperature readings are not displayed. IP packets with options are not forwarded. QinQ access port configured with non-default qinq etype, that is, other than 0x8100, traffic sent on sap 0.* dropped if etype is 0x SAS-D does not display the remote MEP's MAC address in the display output of the CLI show command "show eth-cfm mep <mep-id> domain <md-id> association (maid) all-remote-mepids" The show eth-cfm mep mep-id domain md-id association ma-id command would not display Last CCM Rx-Time, Last CCM Seq Number, CCM Tx Count. ETH-CFM CCM Sequence Check for out-of-sequence CCMs and Last CCM Sequence Number tracking is not done for received CCMs. ETH-CFM CCMs with incorrect DMAC are not dropped by hardware. ETH-CFM CCMs transmitted will always have the Sequence Number as zero. ETH-CFM CCMs with invalid Data TLV-s, Invalid Port/Interface TLV-s do not cause CCM Errors Under a high CPU load, ETH CFM defect reporting and clearing may be delayed. On access ports, protocol packets of EFM, LACP, Dot1x, and DWL are counted as part of SAP statistics if NULL SAP, Dot1q Explicit NULL SAP, or Dot1q Default SAP is configured on an access port. [95361] In VPLS and VLL services, port MTU checks are performed only at the ingress. [92910] Dual rate SFPs (3HE04116AA and 3HE04117AA) connected to GigE SFP require autonegotiation to be disabled to operate in 1G mode. [78737] SAP ingress meters (counters) are incremented for packets dropped by a filter on that SAP. [70878] If the system IP address is not configured, RADIUS user authentication will not be attempted for in-band RADIUS servers unless a source address entry for RADIUS exists. SNMP access cannot be authorized for users by the RADIUS server. RADIUS can be used to authorize access to a user by FTP, console, or both. Page 12 Alcatel-Lucent
13 7210 SAS-D OS 3.0R9 Software Release Notes If the first server in the list cannot find a user the server will reject the authentication attempt. In this case, the 7210 node does not query the next server in the RADIUS server list and denies access. If multiple RADIUS servers are used, the software assumes they all have the same user database. In an Epipe service, traffic is not switched if the source MAC is a multicast or broadcast address [71437] A service configured with 'svc-type any" and null-sap to null-sap allows packets up to 1514 including 4 byte FCS if the port MTU is default value of Workaround is to increase the port MTU from default value of [116239] The system accepts packets with sizes exceeding the port MTU by 4 bytes, as listed in below scenario if egress port has proper MTU to transmit these extra bytes byte (includes 4 byte FCS) single vlan tagged or 1526 byte (includes 4 byte FCS) double vlan tagged packets received on null sap is forwarded where ingress is null port and egress is dot1q/qinq port byte (includes 4 byte FCS) double vlan tagged packet received on dot1q sap is forwarded where ingress port is dot1q and egress is qinq port [75221] A MAC will not age out as long as STP BPDUs from that source are received, although data traffic is not present. [71658] If the TACACS+ start-stop parameter option is enabled for accounting, every command will result with two commands in the accounting log. If TACACS+ is first in the authentication order and a TACACS+ server is reachable, the user will be authenticated for access. If the user is authenticated, the user can access the console and has the rights assigned to the default TACACS+ authenticated user template config>system>security>user-template tacplus_default. Unlike RADIUS, TACACS+ does not have fine granularity for authorization to define if the user has only console or FTP access. The 7210 SAS OS supports a default template for all TACACS+ authenticated users. If TACACS+ is first in the authentication order and the TACACS+ server is not reachable, the authorization for console access for the user is checked against the user s local or RADIUS profile if configured. If the user is not authorized in the local/radius profile, the user is not allowed to access the box. Note that inconsistencies can arise depending on certain combinations of local, RADIUS and TACACS+ configurations. For example, if the local profile restricts the user to only FTP access, the authentication order is TACACS+ before local, the TACACS+ server is up and the TACACS+ default user template allows console access, an authenticated TACACS+ user will be able to log into the console using the default user template because TACACS+ does not provide granularity in terms of granting FTP or console access. If the TACACS+ server is down, the user will be denied access to the console as the local profile only authorizes FTP access. [39392] If a source-address entry is configured for in-band RADIUS servers, the source address (IP address) is used as the NAS IP address, otherwise the IP address of the system interface is used. default.cfg is a file name reserved by the system. Do not create a file with this name in the root directory. [76972] Alcatel-Lucent Page 13
14 7210-SAS D OS 3.0R9 Software Release Notes For a LAG configuration with more than one port, if a meter configuration does not specify a CBS value, some packets may be marked yellow and be treated accordingly when buffer management begins. The solution is to increase the CBS setting whenever the CIR configured for the meter is greater than 1Gbps. For a LAG with two ports, a CBS value of 64Kbits is recommended. [72497] For a LAG configuration with more than one port, every other jumbo frame is dropped. The solution is to increase the MBS from the default value of 128Kbits to 144Kbits for two port LAGs. [73552] In an ingress MAC filter policy, the etype and frame-type match criteria do not match packet fields in those packets received with more than one VLAN tag. [72839] MACs that are already learned do not age out after a filter is added to drop packets from those MACs. [73370] Packets with CRC errors are accounted for in the ingress meter calculations. [80966] Packets discarded as the result of a discard-unknown-source and discard-unknown configuration are accounted for in the ingress meter calculations. [84842] Meter buckets are re-initialized when the rate value is modified. Rate values are modified by explicitly changing the rate values using the appropriate CLI command or by changing the adaptation rule. [84395] Page 14 Alcatel-Lucent
15 7210 SAS-D OS 3.0R9 Software Release Notes KNOWN ISSUES The following are specific technical issues and limitations that exist in Release 3.0R9 of SAS D OS. The topics are arranged alphabetically. ACLS Egress filter attached on * sap affects traffic on other dot1q saps on that port [113270] Egress filter on 0.* [Uplink and Access qinq] sap affects traffic on other qinq saps on that port.[113270] Egress filter attached on: 0 sap affects traffic on other dot1q saps on that port. [115432] IP filter match criteria option-present cannot be used to match packet fields for traffic on IES interfaces. [113272] Egress Filter counters does not work for IES service. A filter entry action value configured as action should force the filter to pick up the default action configured for the filter. This does not work. It is recommended to explicitly configure the action for each filter entry. [76620] CLI The execution of configuration file saved with CLI 'admin save detail' errors out. It is recommended not to save configuration using "admin save detail". There are some unsupported CLI and CLI options displayed in the CLI command set. Some of the show, monitor, and tools CLI command output displays unsupported fields and modules. The output of the tools dump command is not aligned properly when issued from a Telnet session. [76876] In the Telnet session, the output for tools dump is not properly displayed. [80661] IP IP packets that need fragmentation are not forwarded. However, if the ARP is not resolved for the next-hop, only the first packet is fragmented and sent out as soon as the ARP is resolved. Only CPU-generated packets are fragmented. [76353] The ping ip-address detail command should report the interface on which the ping reply was received. This information does not display in the output. [76887] SNMP query of the vrtractivearpentries object does not return the correct value. The CLI reports the correct number of ARP entries. [80788] LAG In an LAG, if port is down due no lacp packets received from other end then unlearned traffic sent on other active ports of lag is also flooded on the oper down port. MANAGEMENT If a source-address is configured for NTP, and if the system is rebooted with an older time set (using admin set-time), NTP takes a few iterations to synchronize for the first time. [86897] SNMP operations on some unsupported SNMP MIBs might succeed. Alcatel-Lucent Page 15
16 7210-SAS D OS 3.0R9 Software Release Notes There is currently no show command to display the current values of password hash settings. [32747] When logged in with the Telnet client supplied with Windows and issuing an SSH command to a remote server, an unexpected carriage return may be sent causing the SSH connection to fail. [50657] An asterisk * indicating an unsaved configuration change may not be displayed after changing some of the parameters under some contexts such as the system and log contexts, (for example, *A:ALU-7210>config>system or A:ALU-7210>config>log). Additionally, the Change Since Last Save field in the show system information command output may not be updated. [61271] The CLI allows the user to specify a TFTP location for the destination for the admin save and admin debug-save commands which will overwrite any existing file of the specified name. [18554] SNMP walk of vrtrconfentry shows the vpls-management and management instance as active even though these are not currently supported. [76832] SNMP query of the following operational rates does not return the correct values. The value returned is 0. CLI reports correct operational values. [76853]. - taccessegressqueueoperpir - taccessegressqueueopercir. If an ongoing FTP is aborted, the console and Telnet become unresponsive for a duration that depends on the size of the file being transferred. [76734, 74294] The 7210-SAS D does not support storing more than 500 events for log destination s memory and SNMP. Although the CLI and MIB allows up to 1024 to be configured, it is recommended not to exceed 500. MIRROR Ingress QoS policies applied for forwarded traffic will also be reflected on its mirrored traffic. [73951] OAM On a given SAP in any service, in order to use Y DM, it is recommended to configure only one Y.1731 MEP, otherwise, 2-DM may not work properly. Except 2-DM other functionality not affected even if there are multiple MEP's.[118015] Eth-Cfm convergence fails; when llf is enabled on the LAG SAP and Lag shut and no-shut is done, or box is admin saved and rebooted. Workaround: Remove and add back MEPs. [116513] The show eth-cfm mep mep-id domain md-id association ma-id command would not display CCM ERROR, CCM XCON frames in its output. The show eth-cfm mep mep-id domain md-id association ma-id remote-mep rmep-id command would not display some TLVs and details. ETH-CFM RDI will not be generated for defmacstatus [98332] ETH-CFM defect is not reported on booting the 7210 with a configuration that has the ETH CFM session over a LAG with no member ports [100813] ICMP pings with higher packet sizes sent at higher rates will fail. [77611] Page 16 Alcatel-Lucent
17 7210 SAS-D OS 3.0R9 Software Release Notes Recommended minimum value for EFM OAM timers is tx-interval of 500ms and a multiplier of 4. Even though CLI allows for lesser values, it is not supported. OAM DNS lookups do not work correctly unless the full DNS name is provided. [54239, 54689] Efmoam sessions flap under the following conditions: - Using timers less than the default values, - STP packets that need to be forwarded in the slow-path (CPU-based forwarding) are incoming at a rate >64kbps, and - The CPU utilization is > 80% [76129] For EFM OAM with timers less than the default values can result in EFM flaps due to events such as STP topology change, clearing FDB, or adding and removing ports to a LAG. It is recommended to use the default timers, tx-interval=10 and multiplier=5 or above. [81218, 82228] QOS Operational values for some user configured values of ERL rate are incorrect in the show pool output of a port. [90549] When a 1Gig port is congested, a small amount of excess traffic is sent out of the lower priority queues. The amount of excess traffic depends on the packet sizes. [111644, ] When remarking is enabled on access egress for a Dot1q port, the Dot1p bits in the customer tags get remarked when the traffic is sent out of a Dot1q default SAP or a NULL SAP. [86818] The workaround: In the case of a NULL SAP, remarking can be disabled to preserve the Dot1p bits. With a slope policy, queue depths for lower priority queues do not get limited to maxaverage when the scheduler is in strict mode and if lower priority queue not serviced by scheduler due to high traffic on higher priority queue. [111651] The keyword max in the meter command configuration does not set the rate properly. The semantics of this keyword should set the metered rate to the maximum rate applicable to the interface over which the SAP attached to the meter is created. However, max sets the rate to 4Gbps. Use the applicable numeric value instead. [75845]. The maximum entry-id value for the IP/MAC-criteria in the SAP ingress policy context is restricted to 63 although the CLI allows up to 64. Entry-id 64 should not be specified. [76790/76964] RADIUS In defining RADIUS Vendor Specific Attributes (VSAs), the TiMetra-Default-Action parameter is required even if the TiMetra-Cmd VSA is not used. [13449] SYNCE When SSM clock quality selection is enabled, clock references are selected based on clock quality if revertive mode is configured. [111524] Fixed Copper ports 1/1/7 to 1/1/10 are not supported as SyncE Reference ports.[118949] Alcatel-Lucent Page 17
18 7210-SAS D OS 3.0R9 Software Release Notes SERVICES 7210 SAS-D Default sap (:* sap) does not participate in igmp-snooping process. Following packets are flooded in the service when received on * sap: IGMP General Queries, IGMP Reports/Joins, and Registered and Unregistered Multicast Data Packets.[109045] If service svc-sap-type is configured to any, null sap to null sap accepts packets 4 bytes less than port MTU byte (includes 4 byte FCS) untagged packet received on null sap and egressing on null sap where port encap is null and port mtu is 1514 is dropped. The same packet may be forwarded if egress sap is of different encap (dot1q, QinQ or L2 Uplink). [116239] Priority tagged packets received on 0.* sap may not forwarded if qinq etype for Access/Uplink Qinq port is set to non default value in SAS-D access-uplink mode.[108959] Tagged BPDUs on a null SAP are forwarded by the software. [109624] Packets larger than port MTU are learned and are accounted for by rate limiters. However, they are dropped as expected. [73497] When all the member ports of a LAG are removed and added back, the stats for a SAP on that LAG, belonging to a VPLS or an Epipe service, is reset to zero [73439] Dot1p priority is not preserved for RSTP packets forwarded by the node (for example doubly tagged STP packets received on a SAP). The dot1p is remarked to 7. Additionally, these packets are not matched against egress filter policies. [71855/75921] Changing the fdb-table-size on multiple services simultaneously (for example, by a script) may affect MAC learning in some services. [82362] STATISTICS/ ACCOUNTING Attaching accounting-policy on SAS-D L2 Uplink SAP is not supported and should not be configured, however CLI commands exists.[111897] LACP and CFM protocol packets are not shown in the output packets column of the show lag lag-id statistics command. [77986] STP If an ingress CPU forwarded RSTP/L2PT/PVST packet rate exceeds 128kbps on access, 265kbps on network, RSTP flaps. [73189] If a large number of MAC addresses exists in the VPLS FDB and the entire FDB is flushed and relearned, there may be a period of when RSTP BPDUs are not sent. A partial workaround is to configure fdb-table-size limits. [40532] SYSTEM Internal loopback of port does not work when loopbacked port speed is set to 100Mb and autoneg is turned off.[113995] Fixed Copper port when Internal loopback is enabled and port speed is set to autonegotiated speed. For SPF ports, if port is not shut before loopback is configured, speed is always set to autonegotiated speed. If port is shut before loopback then speed set to 1Gbps.[114904] Sometimes "[iommsg-1]soc_phyctrl_loopback_set: u=0 p=3 TIMEOUT" console message appears when port internal loopback is enabled/disabled on Copper SFP port.[115784] snmpwalk reports redundant power-supply status. [113827] Page 18 Alcatel-Lucent
19 7210 SAS-D OS 3.0R9 Software Release Notes A port LED may glow if a 1Gig fiber SFP is inserted (without connecting a cable) with 100Mbps speed configured. (Note: 100Mbps mode is not supported for 1Gig Fiber SFPs excepting dual-rate fiber SFPs and copper SFPs). [85620] In certain scenarios (such as Cu SFP connected to Fixed Cu), the show port command does not display the MDI/MDX value as expected. Functionality is not affected. [76765] In certain scenarios, traffic drops are seen during source learning when copper ports are operating in half duplex modes. Once learned, there are no other observed drops. [75875] When the show service fdb-mac command is executed through the console while the MDA is initializing (and when traffic is coming into the box), a software crash could occur. To avoid this anomaly, wait until the MDA is initialized and the ports are up before issuing the command. [74051] When the password aging option is enabled, the reference time is the time of the last boot, not the current time. The password expiry will also be reset on every reboot. [64581] The system time MIB object stidateandtime is the UTC time and should not include the time zone offset in SNMP get and set requests. [66553] During auto-config, if a DHCP relay packet for an unrelated DHCP session is received by the system, the system may be non-responsive. [76811]. Inserting and removing SFPs in rapid succession cause the following message to display on the CLI session. SFP/XFP Checksums do not match. If this message is seen, execute a shutdown command followed by a no shutdown command on the offending port to resolve the issue. [76935]. The system saves core dumps at the URL specified in the BOF, while coming up. Specifying a remote location as a core file destination has two issues. - If a remote URL is specified, and if the uplinka cannot be brought up, saving the core dump may not succeed, even if uplinkb is up. - If uplinka s BOF is configured to use DHCP, the IP address acquired by DHCP is not released by the system after saving the core file. Thus, it is recommended to configure the core file destination to be the local flash (cf1). [76764, 76736]. During an auto-boot through DHCP when a ping-address is used in the BOF, the system may enter an inconsistent state during the ping-check phase. This was observed only once during which the user was viewing certain debug commands. [76858] When 1G fiber SFPs are configured with a 100Mbps speed may result in un-predictable behavior. Do not set the speed to 100Mbps for 1G fiber SFPs. [81948] For dual rate fiber SFPs to operate successfully, both sides should be configured with the correct speeds. [82194] When using 100FX SFPs, autonegotiation should be disabled. [99132] The number of files in the root directory is limited to 100. As a possible workaround, create a directory in the root directory to use to save/store files. [75227] HAREDWARE Only one port LEDs is used to indicate port status and link activity. If the LED is lit steady, it indicates link up. If the LED is blinking, it indicates link activity. Alcatel-Lucent Page 19
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch. Software Release Notes
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S60 management software. The AT-S60
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
DCS-3950-52C Fast Ethernet Intelligent Access Switch Datasheet
DCS-3950-52C Fast Ethernet Intelligent Access Switch Datasheet DCS-3950-52C Product Overview DCS-3950-52C switch is Fast Ethernet intelligent security access switch for carrier and MAN networks. It supports
Alcatel-Lucent. Service Access Switch Release 6.1 Rev.04 7 2 1 0 S A S - R 6 O S S o f t w a r e R e l e a s e N o t e s
Alcatel-Lucent Service Access Switch Release 6.1 Rev.04 7 2 1 0 S A S - R 6 O S S o f t w a r e R e l e a s e N o t e s 93-0522-04 V6.1.R4 93-0522-04 V6.1.R4 Alcatel-Lucent Proprietary This document contains
DCS-3950-28CT-POE fully loaded AT PoE Switch Datasheet
DCS-3950-28CT-POE fully loaded AT PoE Switch Datasheet DCS-3950-28CT-POE Product Overview DCS-3950-28CT-POE is fully loaded PoE switch for carrier and enterprises. It supports comprehensive QoS, enhanced
JetNet 5428Gv2. Features. Industrial 24FE+4G Gigabit Managed Ethernet Switch INDUSTRIAL ETHERNET RACKMOUNT SWITCH
INDUSTRIAL ETHERNET RACKMOUNT SWITCH Industrial 24FE+4G Gigabit Managed Ethernet Switch JetNet 5428Gv2 The JetNet 5428G is a 19-inch Gigabit Layer 2+ Industrial switch, equipped with 24 100 Base-TX ports
Ethernet Link SGI-4844F
Ethernet Link SGI-4844F 44 ports 100/1000Mbps SFP + 4 Combo port RJ-45 + 100/1000Mbps SFP slot Layer 2+ Managed Ethernet Switch Overview LinkPro SGI-4844F is a layer-2+ gigabit access switch equipped with
20 GE + 4 GE Combo SFP + 2 10G Slots L3 Managed Stackable Switch
GTL-2691 Version: 1 Modules are to be ordered separately. 20 GE + 4 GE Combo SFP + 2 10G Slots L3 Managed Stackable Switch The LevelOne GEL-2691 is a Layer 3 Managed switch with 24 x 1000Base-T ports associated
AT-S105 Version 1.2.0 Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches
AT-S105 Version 1.2.0 Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches Please read this document before you begin to use the management software. NOTE This
AT-S62 and AT-S62 NE Version 1.2.1 Management Software for AT-8500 Series Switches Software Release Notes
Supported Platforms AT-S62 and AT-S62 NE Version 1.2.1 Software Release Notes AT-S62 and AT-S62 NE Version 1.2.1 Management Software for AT-8500 Series Switches Software Release Notes Please read this
AT-S63 and AT-S63 NE Version 1.0.0 Management Software for the AT-9400 Series Layer 2+ Gigabit Ethernet Switches Software Release Notes
AT-S63 and AT-S63 NE Version 1.0.0 Management Software for the AT-9400 Series Layer 2+ Gigabit Ethernet Switches Software Release Notes Supported Platforms Please read this document before you begin to
16-PORT POWER OVER ETHERNET WEB SMART SWITCH
16-PORT POWER OVER ETHERNET WEB SMART SWITCH User s Manual (DN-95312) - 0 - Content Web Smart Switch Configure login ---------------------------------- 2 Administrator Authentication Configuration ---------------------------------------------
Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B
Management Software AT-S84 User s Guide For the AT-9000/24 Layer 2 Gigabit Ethernet Switch Version 1.1 613-000368 Rev. B Copyright 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication
How To Install An At-S100 (Geo) On A Network Card (Geoswitch)
AT-S100 Version 1.0.3 Patch 1 Management Software for the AT-9000/28 Managed Layer 2 GE ecoswitch and AT-9000/28SP Managed Layer 2 GE ecoswitch Software Release Notes Please read this document before you
Ethernet Link SGI-2424
Ethernet Link SGI-2424 24 Combo Ports (10/100/1000Mbps Copper and Dual-Speed SFP) + 2G TP/SFP Combo Layer 2+ Managed Gigabit Ethernet Switch Overview LinkPro SGI-2424 is a layer-2+ gigabit access switch
ZyXEL MGS-3712F V3.90(BBB.4)C0 Release Note/Manual Supplement
Date: Jun 8, 2011 ZyXEL MGS-3712F V3.90(BBB.4)C0 Release Note/Manual Supplement This document describes the features in the MGS-3712F product for its 3.90(BBB.4)C0 release. Support Platforms: ZyXEL MGS-3712F
Juniper Networks EX Series/ Cisco Catalyst Interoperability Test Results. May 1, 2009
Juniper Networks EX Series/ Cisco Catalyst Interoperability Test Results May 1, 2009 Executive Summary Juniper Networks commissioned Network Test to assess interoperability between its EX4200 and EX8208
TP-LINK. JetStream 28-Port Gigabit Stackable L3 Managed Switch. Overview. Datasheet T3700G-28TQ. www.tp-link.com
TP-LINK JetStream 28-Port Gigabit Stackable L3 Managed Switch Overview TP-LINK s is an L3 managed switch designed to build a highly accessible, scalable, and robust network. The switch is equipped with
How To. Configure Ethernet Protection Switching Ring (EPSR) to Protect a Ring from Loops. Introduction
How To Configure Ethernet Protection Switching Ring (EPSR) to Protect a Ring from Loops Introduction Putting a ring of Ethernet switches at the core of a network is a simple way to increase the network
ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af
ALLNET ALL-SG8926PM Layer 2 FULL Management 24 Port Giga PoE Current Sharing Switch IEEE802.3at/af 24-Port Giga PoE Current Sharing 500W PoE Budget IPv6 and IPv4 Dual Protocol SNMP v1/v2c/v3 SSH version
INDIAN INSTITUTE OF TECHNOLOGY BOMBAY MATERIALS MANAGEMENT DIVISION : (+91 22) 2576 8800 (DR)
Item CORE SWITCH: 24 Ports Item Description 1)General requirements: Switch- modular operating system, non-blocking wire speed performance. Switch solution-capable of providing complete redundancy by using
ZyXEL GS2210-8HP V4.10(AASQ.1)C0 Release Note/Manual Supplement
ZyXEL GS2210-8HP V4.10(AASQ.1)C0 Release Note/Manual Supplement Date: May. 5, 2015 This document describes the features in the GS2210-8HP product for its 4.10(AASQ.1)C0 release. Support Platforms: ZyXEL
AT-GS950/8. AT-GS950/8 Web Users Guide AT-S107 [1.00.043] Gigabit Ethernet Smart Switch. 613-001484 Rev A
AT-GS950/8 Gigabit Ethernet Smart Switch AT-GS950/8 Web Users Guide AT-S107 [1.00.043] 613-001484 Rev A Copyright 2011 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced
HARTING Ha-VIS Management Software
HARTING Ha-VIS Management Software People Power Partnership HARTING Management Software Network Management Automation IT - with mcon Switches from HARTING With the Ha-VIS mcon families, HARTING has expanded
ALLNET ALL8944WMP Layer 2 Management 24 Port Giga PoE Current Sharing Switch
ALLNET ALL8944WMP Layer 2 Management 24 Port Giga PoE Current Sharing Switch 24-Port Giga PoE Current Sharing Pv6 and IPv4 Dual Protocol SNMP v1/v2c/v3 SSH version 2.0 Authentication TACACS+ Jumbo Frames
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches. Software Release Notes
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches Software Release Notes Please read this document before you begin to use the AT-S41 management software.
8-Port Gigabit managed POE Switch. User s Manual. Version: 2.3
8-Port Gigabit managed POE Switch User s Manual Version: 2.3 September 9, 2007 1 TABLE OF CONTENT 1.0 INTRODUCTION... 3 1.1 MAIN FEATURES... 3 1.2 START TO MANAGE THIS SWITCH... 5 2.0 WEB MANAGEMENT...
High Performance 10Gigabit Ethernet Switch
BDCOM S3900 Switch High Performance 10Gigabit Ethernet Switch BDCOM S3900 is a standard L3 congestion-less switch series, which are capable of multi-layer switching and wire-speed route forwarding. Its
EGS7228P. Business Class EGS7228P. 24-port Gigabit AT PoE + 4SFP Smart Switch PRODUCT OVERVIEW
24-port Gigabit AT PoE + 4SFP Smart Switch PRODUCT OVERVIEW EnGenius Smart PoE Switch family is special tailored for Access Points and IP surveillance applications., one of the members from EnGenius Smart
Layer 3 Network + Dedicated Internet Connectivity
Layer 3 Network + Dedicated Internet Connectivity Client: One of the IT Departments in a Northern State Customer's requirement: The customer wanted to establish CAN connectivity (Campus Area Network) for
WSG24POE Switch. User Manual
WSG24POE Switch User Manual Version: 01/01/2011 Introduction! 4 Product Overview! 4 Specifications! 5 Package Contents! 5 Hardware Description! 6 Physical Dimensions/ Weight! 6 Front Panel! 6 LED Indicators!
EX 3500 ETHERNET SWITCH
PRODUCT SPEC SHEET EX 3500 ETHERNET SWITCH EX 3500 ETHERNET SWITCH EQUIPPED THE WIRED ETHERNET SWITCH FOR UNIFIED WIRED-WIRELESS NETWORKS GET ALL THE WIRED NETWORKING FEATURES YOU NEED, PLUS THE SIMPLICITY
AT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches. Software Release Notes
AT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches Product Documentation Software Release Notes Please read this document before you begin to use the AT-S45 management
AlliedWare Plus Version 2.1.2 AT-9000 Layer 2-4 Gigabit Ethernet EcoSwitches Software Release Notes
4 AlliedWare Plus Version 2.1.2 AT-9000 Layer 2-4 Gigabit Ethernet EcoSwitches Software Release Notes Please read this document before you begin to use the management software. The document has the following
ADMINISTRATION GUIDE Cisco Small Business
ADMINISTRATION GUIDE Cisco Small Business 200 Series Smart Switch Administration Guide Contents Chapter 1: Getting Started 1 Starting the Web-based Switch Configuration Utility 1 Launching the Configuration
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches Software Administration Manual December 2013 202-11137-04 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products.
ALL8894WMP. User s Manual. 8-Port 10/100/1000Mbps with 4-port PoE. Web Management Switch
ALL8894WMP 8-Port 10/100/1000Mbps with 4-port PoE Web Management Switch User s Manual Content Content I Introduction..3 Product Overview.3 Web Management Feature.3 Specification..4 Mechanical...4 Performance...5
Command Line Interface
bridge addressdatabase add Adding a Statically Configured Address to an Address Forwarding Database You can add a statically configured address to a forwarding database using the add command on the addressdatabase
7450 ESS OS System Management Guide. Software Version: 7450 ESS OS 10.0 R1 February 2012 Document Part Number: 93-0101-09-01 *93-0101-09-01*
7450 ESS OS System Management Guide Software Version: 7450 ESS OS 10.0 R1 February 2012 Document Part Number: 93-0101-09-01 *93-0101-09-01* This document is protected by copyright. Except as specifically
AT-S63 Version 3.1.0 Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes
AT-S63 Version 3.1.0 Management Software for the AT-9400 Basic Layer 3 Gigabit Ethernet Switches Software Release Notes Please read this document before you begin to use the management software. Supported
7750 SR OS System Management Guide
7750 SR OS System Management Guide Software Version: 7750 SR OS 10.0 R4 July 2012 Document Part Number: 93-0071-09-02 *93-0071-09-02* This document is protected by copyright. Except as specifically permitted
TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL5428E. www.tp-link.com
TP-LINK 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch Overview TP-LINK JetStream L2 managed switch provides high performance, enterprise-level QoS, advanced security strategies and rich layer 2
Carrier Ethernet: New Game Plan for Media Converters
Introduction IEEE Std. 802.3ah, also referred to as Ethernet in the First Mile (EFM) standard, has a well established name within the industry today. It lays out ground rules for implementing Ethernet
Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet
IGS-9812GP Series Industrial 20-port managed Gigabit Ethernet switch with 8x10/100/1000Base-T(X) ports and 12x100/1000Base-X, SFP socket Features Supports O-Ring (recovery time < 30ms over 250 units of
Extreme Networks EAS 100-24t Switch Software Release Notes, Version 1.00
Extreme Networks EAS 100-24t Switch Software Release Notes, Version 1.00 This release note for the EAS 100-24t switch software describes: s on page 1 Supported MIBs on page 7 Known Issues on page 8 Fixed
Management Software. User s Guide AT-S88. For the AT-FS750/24POE Fast Ethernet Smart Switch. Version 1.0. 613-000555 Rev. B
Management Software AT-S88 User s Guide For the AT-FS750/24POE Fast Ethernet Smart Switch Version 1.0 613-000555 Rev. B Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication
TP-LINK L2 Managed Switch
NEW TP-LINK L2 Managed Switch TM NEW TL-SL3428/TL-SL3452 Overview TP-LINK JetStream TM L2 managed switch TL-SL3428/TL-SL3452 provides 24/48 10/100Mbps ports, the switch provide high performance, enterprise-level
Objectives. The Role of Redundancy in a Switched Network. Layer 2 Loops. Broadcast Storms. More problems with Layer 2 loops
ITE I Chapter 6 2006 Cisco Systems, Inc. All rights reserved. Cisco Public 1 Objectives Implement Spanning Tree Protocols LAN Switching and Wireless Chapter 5 Explain the role of redundancy in a converged
Troubleshooting the Firewall Services Module
CHAPTER 25 This chapter describes how to troubleshoot the FWSM, and includes the following sections: Testing Your Configuration, page 25-1 Reloading the FWSM, page 25-6 Performing Password Recovery, page
Easy Smart Configuration Utility
Easy Smart Configuration Utility REV1.1.0 1910010977 CONTENTS Chapter 1 About this Guide...1 1.1 Intended Readers... 1 1.2 Conventions... 1 1.3 Overview of This Guide... 1 Chapter 2 Getting Started...4
TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL3428. www.tp-link.com
TP-LINK TM 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch Overview TP-LINK JetStream TM gigabit L2 managed switch provides 24 10/100Mbps ports. The switch provides high performance, enterprise-level
ADMINISTRATION GUIDE Cisco Small Business
ADMINISTRATION GUIDE Cisco Small Business SFE/SGE Managed Switches 2009 Cisco Systems, Inc. All rights reserved. OL-20139-01 Contents Contents Chapter 1: Getting Started 1 Starting the Application 1 Understanding
How To Switch In Sonicos Enhanced 5.7.7 (Sonicwall) On A 2400Mmi 2400Mm2 (Solarwall Nametra) (Soulwall 2400Mm1) (Network) (
You can read the recommendations in the user, the technical or the installation for SONICWALL SWITCHING NSA 2400MX IN SONICOS ENHANCED 5.7. You'll find the answers to all your questions on the SONICWALL
REMOTE MONITORING MATRIX
802.1ag/Y.1731 BASIC ADVANCED 802.3ah Link 802.1ag/Y.1731 RFC 2544 REMOTE MONITORING MATRIX Featuring a matrix of different features that will help you identify and select which Transition products best
ADMINISTRATION GUIDE Cisco Small Business 300 Series Managed Switch Administration Guide
ADMINISTRATION GUIDE Cisco Small Business 300 Series Managed Switch Administration Guide 10/100 Switches SF 300-08, SF 302-08, SF 302-08MP, SF 302-08P, SF 300-24, SF 300-24P, SF 300-48, SF 300-48P Gigabit
Turning Copper into Gold
Product Description: Turning Copper into Gold Smart ethernet switch filled in a gap between non-web management switch and full web management switch, it not only with many functions of L2 full WEB management
Cisco ASA, PIX, and FWSM Firewall Handbook
Cisco ASA, PIX, and FWSM Firewall Handbook David Hucaby, CCIE No. 4594 Cisco Press Cisco Press 800 East 96th Street Indianapolis, Indiana 46240 USA Contents Foreword Introduction xxii xxiii Chapter 1 Firewall
Alcatel-Lucent. Service Access Switch Release 7.0 Rev.01 7 2 1 0 S A S O S S o f t w a r e R e l e a s e N o t e s
Alcatel-Lucent Service Access Switch Release 7.0 Rev.01 7 2 1 0 S A S O S S o f t w a r e R e l e a s e N o t e s 3HE09537AAAA V7.0.R1 3HE09537AAAA V7.0.R1 Alcatel-Lucent Proprietary This document contains
TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P. www.tp-link.com
Power Budget TP-LINK 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots Overview The provides 24 10/100/1000Mbps ports that supports 802.3at/af-compliant PoE, with a total PoE power supply up to 180W,
hp ProLiant network adapter teaming
hp networking june 2003 hp ProLiant network adapter teaming technical white paper table of contents introduction 2 executive summary 2 overview of network addressing 2 layer 2 vs. layer 3 addressing 2
AlliedWare Plus OS How To Use sflow in a Network
AlliedWare Plus OS How To Use sflow in a Network Introduction sflow is an industry-standard sampling system that is embedded in Allied Telesis' high-performing Layer 3 switches. sflow enables you to use
Juniper / Cisco Interoperability Tests. August 2014
Juniper / Cisco Interoperability Tests August 2014 Executive Summary Juniper Networks commissioned Network Test to assess interoperability, with an emphasis on data center connectivity, between Juniper
OAM Operations Administration and Maintenance
OAM Operations Administration and Maintenance IERU Communications Ltd OAM Rev. A Page 1 of 9 Operations Administration and Maintenance 1. Overview This paper describes the Ethernet and Multi-Protocol Label
Alcalde # 1822 Col. Miraflores C.P. 44270 Guadalajara, Jal. México MX 01 (33) 3854-5975 y 3823-4349 USA 001 (858)-869-5401 (Chulavista, CA.
Tu Sitio de Automatización! LBJetNet385628G Introduction The LBJetNet385628G is an Industrial Modular Managed Ethernet Switch, equipped with 3 modular slot for maximum 24 10/100 Base-TX Ports or 18 100Base-FX
*613-000734 Rev A* PN 613-000734 Rev A 1
AT-S70 Version 1.6.0 Management Software for the Converteon Media Converter Products Software Release Notes Please read this document before you begin to use the management software. Supported Platforms
16x10/100/1000Base-T(X) ports and 8x100/1000Base-X, SFP socket
IGS-9168GP Industrial 24-port managed Gigabit Ethernet switch with 16x10/100/1000Base-T(X) ports and 8x100/1000Base-X, SFP socket Features Supports O-Ring (recovery time < 30ms over 250 units of connection)
20 GE PoE-Plus + 4 GE PoE-Plus Combo SFP + 2 GE SFP L2 Managed Switch, 370W
GEP-2672 Version: 1 20 GE PoE-Plus + 4 GE PoE-Plus Combo SFP + 2 GE SFP L2 Managed Switch, 370W The LevelOne GEP-2672 is a Layer 2 Managed switch with 24 x 1000Base-T PoE-Plus ports associated with 4 x
ProSafe Managed Switch
ProSafe Managed Switch Web Management User Manual Version 9.0.2 GSM5212P GSM7212F GSM7212P GSM7224P 350 East Plumeria Drive San Jose, CA 95134 USA November, 2011 202-10967-01 v1.0 2011 NETGEAR, Inc. All
642 523 Securing Networks with PIX and ASA
642 523 Securing Networks with PIX and ASA Course Number: 642 523 Length: 1 Day(s) Course Overview This course is part of the training for the Cisco Certified Security Professional and the Cisco Firewall
User Manual 24 Port PoE 10/100/1000M with 4 Combo Gigabit SFP Open Slot Web Smart Switch
User Manual 24 Port PoE 10/100/1000M with 4 Combo Gigabit SFP Open Slot Web Smart Switch FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant
Cisco Small Business 300 Series Managed Switch Administration Guide Release 1.2.7
ADMINISTRATION GUIDE Cisco Small Business 300 Series Managed Switch Administration Guide Release 1.2.7 Contents Table of Contents Chapter 1: Getting Started 1 Starting the Web-based Switch Configuration
FGS-2728KX L2+ Managed GbE CE Fiber Switch. Overview
FGS-2728KX L2+ Managed GbE CE Fiber Switch Overview FGS-2728KX L2+ Managed Switch is a next-generation Carrier Ethernet Switch offering full suite of L2 features, L3 Static Route and Carrier Ethernet features
DCRS-5650 Dual Stack Ethernet Switch Datasheet
DCRS-5650 Dual Stack Ethernet Switch Datasheet DCRS-5650-28C Product Overview DCRS-5650 series switch is L3 Fast Ethernet switch which meets the requirements of security and intelligent networks for education
Chapter 7 Configuring Trunk Groups and Dynamic Link Aggregation
Chapter 7 Configuring Trunk Groups and Dynamic Link Aggregation This chapter describes how to configure trunk groups and 802.3ad link aggregation. Trunk groups are manually-configured aggregate links containing
TP-LINK. Gigabit L2 Managed Switch. Overview. Datasheet TL-SG3216 / TL-SG3424. www.tp-link.com
TP-LINK TM Gigabit L2 Managed Switch TL-SG3216 / TL-SG3424 Overview TP-LINK JetStream TM gigabit L2 managed switch 3 series family consists of two switches: TL-SG3216 with 16 10/100/1000Mbps ports and
Troubleshooting the Firewall Services Module
25 CHAPTER This chapter describes how to troubleshoot the FWSM, and includes the following sections: Testing Your Configuration, page 25-1 Reloading the FWSM, page 25-6 Performing Password Recovery, page
MLAG on Linux - Lessons Learned. Scott Emery, Wilson Kok Cumulus Networks Inc.
MLAG on Linux - Lessons Learned Scott Emery, Wilson Kok Cumulus Networks Inc. Agenda MLAG introduction and use cases Lessons learned MLAG control plane model MLAG data plane Linux kernel requirements Other
TP-LINK. 24-Port Gigabit L2 Managed Switch with 4 SFP Slots. Overview. Datasheet TL-SG5428. www.tp-link.com
TP-LINK TM 24-Port Gigabit L2 Managed Switch with 4 SFP Slots Overview Designed for workgroups and departments, from TP-LINK provides full set of layer 2 management features. It delivers maximum throughput
Appendix A Remote Network Monitoring
Appendix A Remote Network Monitoring This appendix describes the remote monitoring features available on HP products: Remote Monitoring (RMON) statistics All HP products support RMON statistics on the
48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W
GEP-5070 Version: 1 48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W The LevelOne GEP-5070 is an intelligent L2 Managed Switch with 48 x 1000Base-T PoE-Plus ports and 2 x 100/1000BASE-X SFP (Small Form
ANNEX III BUDGET PROPOSAL AS PER LOTS LOT 1
ANNEX III BUDGET PROPOSAL AS PER LOTS Item no. UNIT COSTS WITH DELIVERY Comment Technical Specification Quantity Specification Offered INCLUDING INSTALLATION AND PUTTING INTO OPERATION Technical Specification
TP-LINK. 24-Port Gigabit Smart Switch with 4 SFP Slots. Overview. Datasheet T1600G-28TS (TL-SG2424) www.tp-link.com
TP-LINK 24-Port Gigabit Smart Switch with 4 SFP Slots Overview TP-LINK JetStream Gigabit Smart Switch T1600G-28TS is a cost-effective product solution for small and medium-sized business which provides
4 Ports + 3 SFP Gigabit Smart Switch Use Manual. Ver.A0
4 Ports + 3 SFP Gigabit Smart Switch Use Manual Ver.A0 Chapter 1 Product Specification 1.1 Product Characteristics Complies with IEEE802.3,IEEE802.3u,IEEE802.3ab standards; 4 10/100/1000Mbps Auto-Negotiation
Web Interface. Security Network Access Port Security. Enabling and Disabling Port Security
Security Network Access Port Security Enabling and Disabling Port Security You can enable and disable security and set the mode of operation on a port using the Port Security wizard. To access the wizard:
24 GE + 2 GE SFP L2 Managed Switch
GEL-2670 Version: 1 24 GE + 2 GE SFP L2 Managed Switch The LevelOne GEL-2670 is an intelligent L2 Managed Switch with 24 x 1000Base-T ports and 2 x 100/1000BASE-X SFP (Small Form Factor Pluggable) slots.
TP-LINK. 24-Port Gigabit L2 Managed PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG3424P. www.tp-link.com
TP-LINK TM 24-Port Gigabit L2 Managed PoE Switch with 4 Combo SFP Slots Overview The provides 24 10/100/1000Mbps ports that supports 802.3at/af-compliant PoE, with a total PoE power supply up to 320W,
8x10/100/1000Base-T(X) ports and 12x100/1000Base-X, SFP socket
IGS-R9812GP Industrial Layer-3 20-port managed Gigabit Ethernet switch with 8x10/100/1000Base-T(X) ports and 12x100/1000Base-X, SFP socket Features Supports Layer 3 routing, RIP and static routing function
EtherDevice Switch EDS-726 Series
Managed Redundant EtherDevice TM Switch Solutions EtherDevice Switch EDS-726 Series 26-Port Gigabit Ethernet Switch Modular, Managed, Redundant Features Industrial Networking Capability Redundant Gigabit
Command Line User s Guide
Management Software AT-S63 Command Line User s Guide For AT-9400 Switch Stacks AT-S63 Version 3.2.0 for AT-9400 Basic Layer 3 Switches 613-001027 Rev. A Copyright 2008 Allied Telesis, Inc. All rights reserved.
DGS-3400 Series Firmware Release Notes
Firmware Version: V2.60.B26 Prom Code Version: V1.00.B13 Published: February 25, 2010 These release notes include important information about D-Link switch firmware revisions. Please verify that these
Internet Protocol: IP packet headers. vendredi 18 octobre 13
Internet Protocol: IP packet headers 1 IPv4 header V L TOS Total Length Identification F Frag TTL Proto Checksum Options Source address Destination address Data (payload) Padding V: Version (IPv4 ; IPv6)
Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: ES-24-250W, ES-24-500W, ES-48-500W, ES-48-750W
Managed PoE+ Gigabit Switches with SFP Models: ES-24-250W, ES-24-500W, ES-48-500W, ES-48-750W Non-Blocking Throughput Switching Performance Gigabit Ethernet RJ45 and SFP+/SFP Ports Auto-Sensing IEEE 802.3af/at
Read Me First for the HP ProCurve Routing Switch 9304M and Routing Switch 9308M
Read Me First for the HP ProCurve Routing Switch 9304M and Routing Switch 9308M Contents: Software Updates Are Free! New Software Release 05.0.84 Module Installation Getting Started Your Free Ticket to
P330-ML Version 4.5 Release Notes
Avaya P330-ML Version 4.5 Release Notes 1. Introduction This document contains information related to the Avaya P332G-ML, P332GT-ML and P334T-ML stackable switches that was not included in the User's Guide.
Cisco Certified Network Associate Exam. Operation of IP Data Networks. LAN Switching Technologies. IP addressing (IPv4 / IPv6)
Cisco Certified Network Associate Exam Exam Number 200-120 CCNA Associated Certifications CCNA Routing and Switching Operation of IP Data Networks Operation of IP Data Networks Recognize the purpose and
EdgeRouter Lite 3-Port Router. Datasheet. Model: ERLite-3. Sophisticated Routing Features. Advanced Security, Monitoring, and Management
EdgeRouter Lite 3-Port Router Model: ERLite-3 Sophisticated Routing Features Advanced Security, Monitoring, and Management High-Performance Gigabit Ports Advanced 3-Port Router Introducing the EdgeRouter
User Guide XMS-1024P 24 Port Gigabit Managed PoE/PoE+ Switch
Simply Connected User Guide XMS-1024P 24 Port Gigabit Managed PoE/PoE+ Switch Use the XMS-1024P to: Cost-effectively Add 802.3af/at PoE Capability to Your Network Deliver Power and Data for up to 24 PoE-Enabled
ENTERASYS WEBVIEW WEB-BASED MANAGEMENT FOR THE VH-2402S/VH-2402S2 WEB MANAGEMENT GUIDE
ENTERASYS WEBVIEW WEB-BASED MANAGEMENT FOR THE VH-2402S/VH-2402S2 WEB MANAGEMENT GUIDE 9033821 Notice NOTICE Enterasys Networks reserves the right to make changes in specifications and other information
Gigabit Ethernet Web Smart 8-Port Switch 2 Combo SFP Open Slot
Gigabit Ethernet Web Smart 8-Port Switch 2 Combo SFP Open Slot User s Manual (DN-80201) Content Introduction ------------------------------------------------------------------------------------4 Product
Ha-VIS FTS 3000 Introduction and features
Ha-VIS Introduction and features Ethernet Switch Ha-VIS FTS 3100s-A 10-port Ethernet Switch with Fast Track Technology configurable via USB General Description Features The Fast Ethernet Switches of the