1 Intel RAID High Availability Solution for Red Hat * Linux Systems Best Practices White Paper Revision 1.0 January, 2014

2 Revision History Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Revision History Date Revision Number January, Initial release. Modifications ii Intel Confidential Revision 1.0

3 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Disclaimers Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or indirectly, in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH MISSION CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES, SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH, HARMLESS AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS' FEES ARISING OUT OF, DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL INJURY, OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined". Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information. The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling , or go to: Intel and Xeon are trademarks of Intel Corporation in the U.S. and/or other countries. *Other names and brands may be claimed as the property of others. Copyright 2014 Intel Corporation. All rights reserved. Revision 1.0 Intel Confidential iii

4 Table of Contents Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Table of Contents 1. Introduction Background Requirements and Configuration Diagram Installation Download Release Package Install Release Package Install and Update the HA RAID Controllers Operating System Installation Network Configuration Installation of Intel HA RAID Drivers and Intel RAID Web Console Installation of HA Cluster Packages Firewall and SELinux Changes Configure the HA Cluster Create an HA Cluster Configure the Fence Devices Create a Failover Domain Configuring Cluster Resources Add a Cluster Service and Assign a Resource to the Service Create a Disk Quorum Propagate the Configuration File to the Cluster Nodes Start the CMAN Service Reference Documents...22 iv Intel Confidential Revision 1.0

5 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper List of Figures List of Figures Figure 1. Two Server and JBOD Configuration Diagram... 2 Figure 2. Enter the BIOS Boot Manager and EFI Shell... 3 Figure 3. Install the Release Package... 4 Figure 4. Install the RAID Controller HA Key... 5 Figure 5. Open the Network Configuration File... 7 Figure 6. Edit the Network Configuration File... 7 Figure 7. Install the Packages Figure 8. Confirm the Package Download Size Figure 9. Confirm the Package Signature Information Figure 10. Change the Software Firewall Figure 11. Change the SELinux Settings Figure 12. Verify IPMI Settings Figure 13. Create a Disk Quorum Figure 14. Start the cman Service Figure 15. Check the Cluster Configuration Revision 1.0 Intel Confidential v

6 List of Figures Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper < This page intentionally left blank. > vi Intel Confidential Revision 1.0

7 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Introduction 1. Introduction 1.1 Background The Intel RAID High Availability (HA) Solution is designed for small-to-medium businesses, remote/branch offices or private cloud environments that need a high availability configuration of a server with local storage. This configuration of the Intel RAID HA solution provides two servers, two hardware RAID controllers, and shared local storage with SAS disk drives. This solution takes advantage of Linux clustering technology to provide the high availability environment in a two-node cluster and takes advantage of the SAS interface to allow sharing of storage. The overall design goal is to provide the high availability solution with a simple installation and ease-of-use experience for the user or value-added-reseller. 1.2 Requirements and Configuration Diagram The Intel RAID HA solution requires the following: Two Intel servers (R2312 or equivalent) Two Intel hardware RAID Controllers (RS25SB008) plus the enablement key for each controller The AXXRPFKHA2 enablement key kit which contains 1 key for each controller External JBOD (JBOD2224S2DP) Supported SAS disk drives (SATA drives are not supported) SAS cables connecting the servers to the JBOD storage unit Red Hat* Enterprise Linux 6.3 or higher This solution fits into a typical infrastructure and includes server node 1, server node 2, and the External JBOD SAS Drive Enclosure as indicated in the diagram below. As with any server cluster solution, there needs to be a private LAN dedicated to cluster server communications in addition to the public LAN that communicates with client systems. The public network must provide Domain and Active Directory services, as well as DNS services to the failover cluster server. Revision 1.0 Intel Confidential 1

8 Introduction Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Figure 1. Two Server and JBOD Configuration Diagram 2 Intel Confidential Revision 1.0

9 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Installation 2. Installation The installation process is detailed below. Some of these steps are performed using the server BIOS/UEFI utilities before the operating system is installed and some are performed using the operating system tools after the operating system is installed. Important note: Because a server cluster will be created, some of the steps require updates to be applied to one server, and then to the second server before proceeding to the following step. 2.1 Download Release Package Use RAID FW, driver, RWC2, CLI, and SMI-S in IR3_2208_HA-DAS_release_package_1.0 drop or later version. The latest version is available on the Intel Support Website at: (Search High Availability Software ). A USB flash drive is needed to store the images from the release package, and will be used to install them via the server BIOS/UEFI setup tools. The release package is a single, zipped file. This file must be unzipped. Inside this package is a PDF document and five zipped files. Each of these five zipped files must be unzipped. The resulting five file folders and their contents are required to be copied to the USB flash drive. 2.2 Install Release Package 1. To install the package updates, enter the BIOS Boot Manager and then the EFI Shell on server node 1. Tip: Do not plug the USB flash drive with the updates into the server until after you are in the BIOS setup. Figure 2. Enter the BIOS Boot Manager and EFI Shell Revision 1.0 Intel Confidential 3

10 Installation Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper 2. Using the EFI Shell, navigate (using the cd command) to the folder named: ir3_2208-hadas_fwpkg-v Figure 3. Install the Release Package 3. Run the shell script named: UPDATE.NSH After the package completes its download, restart the server and repeat for the second server. 4 Intel Confidential Revision 1.0

11 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Installation 2.3 Install and Update the HA RAID Controllers 1. To install the RAID controller HA key, shut down the server, remove the power cords, open the lid, and install the HA key onto the RAID controller. 2. Repeat this process for both servers. Figure 4. Install the RAID Controller HA Key 3. After each HA key has been installed on each of the RAID controllers in each of the servers, close the lid on the servers. Remove the USB flash drive containing the drivers. 4. Install the SAS disk drives into the JBOD storage unit and then power on the JBOD storage unit. Note: SATA disk drives are not supported with this solution. Supported SAS disk drives are dual-ported and are required for the HA RAID solution. 5. Connect the SAS cables between the servers and the external JBOD storage unit, as exactly shown in the Figure 1. Verify that a private LAN exists between the two servers. This private LAN connection will be used for the cluster heart beat and related cluster server communications. The public LAN must have a Windows Domain Controller and DNS server. The HA RAID cluster nodes should be neither a domain controller nor a DNS server. 6. After connecting the SAS cables, reconnect the power cords into the servers and power on the servers. Revision 1.0 Intel Confidential 5

12 Installation Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper 2.4 Operating System Installation The operating system can be installed to drives connected to the raid controller, or to drives connected to the server board ports. In this example, Red Hat* Enterprise Linux is used. Example #1: Install two hard disk drives or SSDs (SSDs are an excellent choice due to the faster boot that they provide) with at least 200GB capacity and connect them to the on-board SAS or SATA ports, and configure them as a mirror using either RSTe or ESRT2 server board raid options. For additional information refer to the documentation for the server system chosen for use. Example #2: Configure a virtual drive using drives connected the RS25SB008 RAID Controller, however, there must be enough capacity in the remaining drives connected to the raid controller to configure a quorum disk and volumes for shared failover. For additional information, see the RAID controller hardware guide. 1. Install Enterprise Linux from the DVD or using typical methods. In this example, the two servers are named HA01.SH and HA02.SH. The following basic configuration steps need to be completed for each server after the basic operating system installation. These are: a) Network Configuration b) Installation of Intel HA RAID Drivers and Intel RAID Web Console 2 c) Installation of HA Cluster Packages d) Firewall and SELinux Changes e) Configure the HA Cluster 2. Using the command-line prompt, login to the server as root and enter the root password. 6 Intel Confidential Revision 1.0

13 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Installation 2.5 Network Configuration In this example, the server is configured with a static IP address. Each server should be configured with its own static IP address. The steps to configure the network for the first server are shown below. 1. Enter the command: cd /etc/sysconfig/network-scripts/ 2. Edit the file corresponding to your newly configured network using vi or your preferred text editor. Figure 5. Open the Network Configuration File 3. Edit the ifcfg-eth0 file with proper IP address. 4. Set ONBOOT=yes and remove any unnecessary lines from this file and then save it. Figure 6. Edit the Network Configuration File Revision 1.0 Intel Confidential 7

14 Installation Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper 5. Repeat steps above to assign a different IP address for other node in the HA cluster. 6. Edit the /etc/hosts file on each node to provide the IP address and its hostname. For example: The IP address of HA01.SH is The IP address of HA02.SH is The Network Manager is not supported on cluster nodes and should be removed or disabled. To disable it, run the following commands at the command prompt for both nodes: service NetworkManager stop chkconfig NetworkManager off 8. Reboot the both nodes to make network settings effective. 8 Intel Confidential Revision 1.0

15 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Installation 2.6 Installation of Intel HA RAID Drivers and Intel RAID Web Console 2 So that each node in the cluster that will be created can access the shared JBOD storage, the Intel ir HA RAID drivers must be installed into each node of the cluster. If this driver has been loaded during Linux OS installation, the following steps 1 to 4 can be ignored. 1. Check whether other version ir RAID driver has been installed on each node of cluster by running the following command: lsmod grep mega If megaraid_sas is listed, other version ir RAID driver has been installed. 2. Run the following command to remove the other version ir RAID driver if it has been installed on Linux: rmmod megaraid_sas 3. Run the following command to copy the ir HA driver RPM package to any folder of Linux OS: rpm ivh [ir HA driver rpm package] 4. Run the following command to insert new version driver module: modprobe megaraid_sas Revision 1.0 Intel Confidential 9

16 Installation Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper 5. Install the Intel RAID Web Console 2 on one node in the cluster. Then create the shared RAID volumes for cluster with this tool. For installation details, refer to the Intel RAID High Availability Storage User Guide at 10 Intel Confidential Revision 1.0

17 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Installation 2.7 Installation of HA Cluster Packages To install the Linux HA cluster system, the following packages are needed: rgmanager rgmanager is the Resource Group (Service) Manager. It controls starting, stopping, migrating, relocating, and recovering services with the HA cluster. lvm2-cluster The lvm2-cluster package contains support for Logical Volume Management (LVM) in a clustered environment. gfs2utils The gfs2utils package contains a number of utilities for creating, checking, modifying, and correcting any inconsistencies in global filesystem (GFS2) filesystems. ccs/luci/ricci The CCS (cluster configuration system) allows an administrator to create, modify, and view a cluster configuration file on a remote node through ricci or a local file. Luci is web frontend providing HA cluster suite management GUI. It is a required prerequisite to have ricci package deployed and started on respective nodes before the cluster can be managed with luci. cman The Cluster Manager (cman) handles communications between nodes in the cluster, determining when a node enters or leaves the cluster. To help to resolve the complex dependency problem, the yum (Yellow Dog Updater Modified) tool is often used to install the packages above. The packages are downloaded from collections called repositories, which may be on internet, on a local network, or on installation media. If your server has no internet access, or you cannot access to some public package repositories, local installation media can be a better choice. The following steps show how to install these packages from local media. 1. Verify that the yum tool has been installed on your Linux system. 2. Add a new file named local.repo in the folder /etc/yum.repos.d, with the following contents: [Server] name=server baseurl=file:///media/cdrom/server enable=1 gpgcheck=0 [HighAvailability] name=highavailability baseurl=file:///media/cdrom/highavailability enable=1 gpgcheck=0 [LoadBalancer] name=loadbalancer Revision 1.0 Intel Confidential 11

18 Installation Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper baseurl=file:///media/cdrom/loadbalancer enable=1 gpgcheck=0 [ScalableFileSystem] name=scalablefilesystem baseurl=file:///media/cdrom/scalablefilesystem enable=1 gpgcheck=0 [ResilientStorage] name=resilientstorage baseurl=file:///media/cdrom/resilientstorage enable=1 gpgcheck=0 3. Create a new folder CDROM in the folder /media and mount the Linux installation media to the folder /media/cdrom. 4. Use yum to install rgmanager, lvm2-cluster, and gfs2utils. Figure 7. Install the Packages 12 Intel Confidential Revision 1.0

19 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Installation 5. Answer y when prompted to confirm the package download size and when prompted to confirm the package signature information. Figure 8. Confirm the Package Download Size Figure 9. Confirm the Package Signature Information 6. (Optional) When the installation of the packages is complete, reply with: yum update Note: This step assumes that both nodes have been registered with Red Hat using the Red Hat Subscription Manager. Revision 1.0 Intel Confidential 13

20 Installation Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper 7. The ricci and cman packages will be installed on each node automatically when the rgmanager package is installed. The CCS can be installed on any node to manage the whole HA cluster. Install the CCS with command: yum install ccs 8. Start the HA cluster services and configure the server to start on boot with the following commands: service rgmanager start service ricci start 14 Intel Confidential Revision 1.0

21 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Installation 2.8 Firewall and SELinux Changes Firewall and SELinux settings should be updated on all nodes in an HA cluster to make sure that the network communication authority and security policies are proper. To support clustering, changes need to be made to the software firewall. These are described at the following link including the use of the service iptables and chkconfig iptables commands: US/Red_Hat_Enterprise_Linux/6/html/Cluster_Administration/s2-iptables_firewall-CA.html To simplify the complexity, we turn off firewall and SELinux in this white paper. Figure 10. Change the Software Firewall Update the SELinux configuration with command: vi /etc/selinux/config. Set SELINUX=disabled in this file and save. Reboot the server to make the changes effective. Figure 11. Change the SELinux Settings Revision 1.0 Intel Confidential 15

22 Installation Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper 2.9 Configure the HA Cluster There are multiple methods to configure the HA cluster, such as using command line, directly editing configuration files, and using a GUI. Configuring an HA cluster occurs on a single node and is then pushed to the remiaining nodes in the cluster Create an HA Cluster Perform the following steps to create the HA cluster with CCS command line: 1. Specify your password for ricci with command: passwd ricci 2. Start the following services: service ricci start service rgmanager start 3. Create an HA cluster. Create the HA cluster with the following command: ccs -h host --createcluster clustername Host is the hostname of the node where the cluster.conf file will be created. Clustername can be defined by the user. For example: ccs h HA02.SH --createcluster mycluster The system will ask for the password that you have defined for ricci at step Add nodes to the cluster. Configure the nodes that the cluster contains by running the following command: ccs -h host --addnode node For example: ccs h HA02.SH --addnode HA02.SH ccs h HA02.SH --addnode HA01.SH 16 Intel Confidential Revision 1.0

23 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Installation Configure the Fence Devices Fencing is the process of locking resources away from a node whose status is uncertain. There are a variety of fencing techniques available: Power fencing A fencing method that uses a power controller to power off an inoperable node. Fibre Channel switch fencing A fencing method that disables the Fibre Channel port that connects storage to an inoperable node. GNBD fencing A fencing method that disables an inoperable node's access to a GNBD server. IPMI fencing A fencing method that uses IPMI protocal and BMC to power off an inoperable node. The user should select proper fencing method according to actual needs. Intel server usually has BMC and supports IPMI spec 2.0. IPMI fencing has the advantage of a lower cost with no additional HW investment. This section uses IPMI fencing configuration as an example. 1. Set up the BMC IP address, account, and password for each node in the cluster. Refer to the Intel Server Management Guide ( for how to set up the BMC properties. For example: Nodes Name BMC IP BMC Account Name BMC Account Password HA01.SH admin password HA02.SH admin password 2. Install IPMItool on each node with command yum install ipmitool. 3. Verify the BMC configuration. Run the following ipmitool command on node HA02.SH to check the system power status of HA01.SH. You cannot check the power status of HA02.SH on the same node. Figure 12. Verify IPMI Settings The BMC configuration is well if you can get its power status. 4. Add a fence method for the node, providing a name for the fence method with the following command: ccs -h host --addmethod method node Revision 1.0 Intel Confidential 17

24 Installation Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper For example, add a method fencemethod_ipmi for both nodes: CCS h HA02.SH addmethod fencemethid_ipmi HA01.SH CCS h HA02.SH addmethod fencemethid_ipmi HA02.SH 5. Add a fence device for the fence method with the following command: ccs -h host --addfencedev node1fence agent=fence_ipmilan ipaddr=ipmi_ip login=ipmi_user passwd=ipmi_passwd auth=md5 action=off For example, add the fence device node1fence and node2fence for node1 and node2: ccs h HA02.SH --addfencedev node1fence agent=fence_ipmilan ipaddr= login=admin passwd=password auth=md5 action=off ccs h HA02.SH --addfencedev node2fence agent=fence_ipmilan ipaddr= login=admin passwd=password auth=md5 action=off 6. Add a fence instance for the fence method with the following command: ccs -h host --addfenceinst fencedevicename node method For example: ccs -h HA02.SH --addfenceinst node1fence HA01.SH fencemethid_ipmi ccs -h HA02.SH --addfenceinst node2fence HA02.SH fencemethid_ipmi Create a Failover Domain By default, all of the nodes can run any cluster service. A failover domain is a named subset of cluster nodes that are eligible to run a cluster service in the event of a node failure. A failover domain can have the following characteristics: Unrestricted Allows you to specify that a subset of members is preferred, but that a cluster service assigned to this domain can run on any available member. Restricted Allows you to restrict the members that can run a particular cluster service. If none of the members in a restricted failover domain are available, the cluster service cannot be started (either manually or by the cluster software). Unordered When a cluster service is assigned to an unordered failover domain, the member on which the cluster service runs is chosen from the available failover domain members with no priority ordering. Ordered Allows you to specify a preference order among the members of a failover domain. The member at the top of the list is the most preferred, followed by the second member in the list, and so on. 18 Intel Confidential Revision 1.0

25 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Installation Failback Allows you to specify whether a service in the failover domain should fail back to the node that it was originally running on before that node failed. Circumstances where a node repeatedly fails and is part of an ordered failover domain. To configure a failover domain, perform the following procedure: 1. Run the following command to add a failover domain: ccs -h host --addfailoverdomain name [restricted] [ordered] [nofailback] For example: ccs -h HA02.SH --addfailoverdomain example_01 ordered 2. Add a node to a failover domain with the following command: ccs -h host --addfailoverdomainnode failoverdomain node priority For example: ccs -h HA02.SH - addfailoverdomainnode example_01 HA01.SH 1 ccs -h HA02.SH - addfailoverdomainnode example_01 HA02.SH Configuring Cluster Resources Shared resources can be shared directories or properties, such as the IP address, that are tied to the cluster. You can configure two types of resources: Global Resources that are available to any service in the cluster. Service-specific Resources that are available to only one service. To add a global cluster resource, execute the following command: ccs -h host --addresource resourcetype [resource options] For example, the following command adds a global file system resource to the cluster configuration file on HA02.SH. The name of the resource is example_fs, the file system device is /dev/sda1 (is a potation on shared storage volume), the file system mountpoint is /HA, and the file system type is ext3. ccs -h HA02.SH --addresource fs name=example_fs device=/dev/sda1 mountpoint=/ha fstype=ext3 Create an IP address cluster resource: ccs -h HA02.SH --addresource ip address= monitor_link=on sleeptime=1 Revision 1.0 Intel Confidential 19

26 Installation Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Add a Cluster Service and Assign a Resource to the Service Add a service to the cluster with the following command: ccs -h HA02.SH --addservice web-service domain=example_01 name=webservice recovery=relocate Here web-service is service name, and example_01 is cluster failover domain name. Assign resources to the service with command -addsubservice, for example: ccs -h HA02.SH --addsubservice web-service ip ref= ccs -h HA02.SH --addsubservice web-service clusterfs ref=example_fs Create a Disk Quorum The disk quorum allows the cluster manager to determine which nodes in the cluster are dominant using a shared storage disk (block device) as the medium. A shared virtual drive of at least 10MB will need to be configured for the disk quorum device. Perform the following steps to make a disk quorum (qdisk): 1. Create or choose a small capacity Shared VD for the disk quorum (the example assumes a RAID 0 VD with mounting at /dev/sdb with mr_qdisk as the quorum disk name) by running the following command: mkqdisk -c /dev/sdb -l mr_qdisk Figure 13. Create a Disk Quorum 2. Check whether qdisk was created on both nodes by running the following command: mkqdisk -L 3. Use the following command to configure your system for using a quorum disk: ccs -h host --setquorumd [quorum d options] Refer to the cluster schema at /usr/share/cluster/cluster.rng for a complete list of quorum disk parameters. For example: ccs -h HA02.SH --setquorumd label= mr_qdisk 20 Intel Confidential Revision 1.0

27 Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper Installation Propagate the Configuration File to the Cluster Nodes After you have created or edited a cluster configuration file on one of the nodes in the cluster, you need to propagate that same file to all of the cluster nodes and activate the configuration. For example, propagate the cluster.conf file to all nodes in the cluster: ccs -h HA02.SH --sync --activate Start the CMAN Service Start the cman service from all nodes in the cluster with the following command: service cman start Figure 14. Start the cman Service Note: The Network Manager needs to be stopped using the service NetworkManager stop and chkconfig NetworkManager off commands. The cluster cannot be started until these two commands have been completed. Run command cman_tool nodes to list all nodes in the cluster. The cluster is now operational. Figure 15. Check the Cluster Configuration For additional information regarding the Intel RAID High Availability and Intel RAID, visit Revision 1.0 Intel Confidential 21

28 Reference Documents Intel RAID High Availability Solution for Red Hat* Linux Systems White Paper R2312 Server 1 RS25SB008 Intel RAID High Availability Storage User Guide AXXRPFKHA2 JBOD2224S2DP Intel Test Hardware and O.S. List Red Hat* Enterprise Linux High Availability Red Hat* Enterprise Linux 6 Cluster Administration SUSE* Linux Enterprise High Availability SUSE* Linux Enterprise High Availability Guide Reference Documents AXXRPFKHA2?q=Intel RAID Premium Feature Key AXXRPFKHA htm US/Red_Hat_Enterprise_Linux/6/pdf/Cluster_Administration/Red_Hat_Ente rprise_linux-6-cluster_administration-en-us.pdf a.pdf 1. This server system is an example of a server that is compatible with this configuration; for a complete list of servers supported by this RAID controller see the RS25SB008 Tested Hardware and Operating System List above. 22 Intel Confidential Revision 1.0

Intel Data Migration Software

Intel Data Migration Software User Guide Software Version 2.0 Document Number: 324324-002US INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY

More information

iscsi Quick-Connect Guide for Red Hat Linux

iscsi Quick-Connect Guide for Red Hat Linux iscsi Quick-Connect Guide for Red Hat Linux A supplement for Network Administrators The Intel Networking Division Revision 1.0 March 2013 Legal INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH

More information

How to Configure Intel X520 Ethernet Server Adapter Based Virtual Functions on Citrix* XenServer 6.0*

How to Configure Intel X520 Ethernet Server Adapter Based Virtual Functions on Citrix* XenServer 6.0* How to Configure Intel X520 Ethernet Server Adapter Based Virtual Functions on Citrix* XenServer 6.0* Technical Brief v1.0 December 2011 Legal Lines and Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED

More information

Intel Entry Storage System SS4000-E

Intel Entry Storage System SS4000-E Intel Entry Storage System SS4000-E Software Release Notes March, 2006 Storage Systems Technical Marketing Revision History Intel Entry Storage System SS4000-E Revision History Revision Date Number 3 Mar

More information

Intel Technical Advisory

Intel Technical Advisory This Technical Advisory describes an issue which may or may not affect the customer s product Intel Technical Advisory 5200 NE Elam Young Parkway Hillsboro, OR 97124 TA-1054-01 April 4, 2014 Incorrectly

More information

This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.

This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer. Installation Guide This guide explains how to install an (Intel SSD) in a SATA-based desktop or notebook computer. The instructions include migrating your data from your current storage device (such as

More information

How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1

How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1 How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1 Technical Brief v1.0 February 2013 Legal Lines and Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED

More information

Intel Internet of Things (IoT) Developer Kit

Intel Internet of Things (IoT) Developer Kit Intel Internet of Things (IoT) Developer Kit IoT Cloud-Based Analytics User Guide September 2014 IoT Cloud-Based Analytics User Guide Introduction Table of Contents 1.0 Introduction... 4 1.1. Revision

More information

Customizing Boot Media for Linux* Direct Boot

Customizing Boot Media for Linux* Direct Boot White Paper Bruce Liao Platform Application Engineer Intel Corporation Customizing Boot Media for Linux* Direct Boot October 2013 329747-001 Executive Summary This white paper introduces the traditional

More information

System Event Log (SEL) Viewer User Guide

System Event Log (SEL) Viewer User Guide System Event Log (SEL) Viewer User Guide For Extensible Firmware Interface (EFI) and Microsoft Preinstallation Environment Part Number: E12461-001 Disclaimer INFORMATION IN THIS DOCUMENT IS PROVIDED IN

More information

Monthly Specification Update

Monthly Specification Update Intel Server Board S1200BTLR Intel Server Board S1200BTSR Intel Server Board S1200BTLRM Intel Server System R1304BTLSFANR Intel Server System R1304BTSSFANR Intel Server System R1304BTLSHBNR Intel Server

More information

Partition Alignment of Intel SSDs for Achieving Maximum Performance and Endurance Technical Brief February 2014

Partition Alignment of Intel SSDs for Achieving Maximum Performance and Endurance Technical Brief February 2014 Partition Alignment of Intel SSDs for Achieving Maximum Performance and Endurance Technical Brief February 2014 Order Number: 330105-001US INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL

More information

Intel vpro Technology. How To Purchase and Install Symantec* Certificates for Intel AMT Remote Setup and Configuration

Intel vpro Technology. How To Purchase and Install Symantec* Certificates for Intel AMT Remote Setup and Configuration Intel vpro Technology How To Purchase and Install Symantec* Certificates for Intel AMT Remote Setup and Configuration Document Release Date: September 14, 2012 Revision History Revision Revision History

More information

Monthly Specification Update

Monthly Specification Update Monthly Specification Update Intel Server Board S1400FP Family August, 2013 Enterprise Platforms and Services Marketing Enterprise Platforms and Services Marketing Monthly Specification Update Revision

More information

Intel Ethernet and Configuring Single Root I/O Virtualization (SR-IOV) on Microsoft* Windows* Server 2012 Hyper-V. Technical Brief v1.

Intel Ethernet and Configuring Single Root I/O Virtualization (SR-IOV) on Microsoft* Windows* Server 2012 Hyper-V. Technical Brief v1. Intel Ethernet and Configuring Single Root I/O Virtualization (SR-IOV) on Microsoft* Windows* Server 2012 Hyper-V Technical Brief v1.0 September 2012 2 Intel Ethernet and Configuring SR-IOV on Windows*

More information

Intel System Event Log (SEL) Viewer Utility

Intel System Event Log (SEL) Viewer Utility Intel System Event Log (SEL) Viewer Utility User Guide Document No. E12461-003 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE GENERAL PURPOSE OF SUPPORTING

More information

Parallels Virtuozzo Containers 4.7 for Linux

Parallels Virtuozzo Containers 4.7 for Linux Parallels Virtuozzo Containers 4.7 for Linux Deploying Clusters in Parallels-Based Systems Copyright 1999-2011 Parallels Holdings, Ltd. and its affiliates. All rights reserved. Parallels Holdings, Ltd.

More information

Linux Cluster. Administration

Linux Cluster. Administration Administration RHEL 5 Linux Cluster 1 Cluster Basics What is cluster Cluster types Storage High Availability Load balancing High performance 2 Storage Clusters Provide consistent file system image across

More information

Configuring and Managing a Red Hat Cluster. Red Hat Cluster for Red Hat Enterprise Linux 5

Configuring and Managing a Red Hat Cluster. Red Hat Cluster for Red Hat Enterprise Linux 5 Configuring and Managing a Red Hat Cluster Red Hat Cluster for Red Hat Enterprise Linux 5 Configuring and Managing a Red Hat Cluster: Red Hat Cluster for Red Hat Enterprise Linux 5 Copyright 2007 Red Hat,

More information

Intel System Event Log (SEL) Viewer Utility. User Guide SELViewer Version 10.0 /11.0 December 2012 Document number: G88216-001

Intel System Event Log (SEL) Viewer Utility. User Guide SELViewer Version 10.0 /11.0 December 2012 Document number: G88216-001 Intel System Event Log (SEL) Viewer Utility User Guide SELViewer Version 10.0 /11.0 December 2012 Document number: G88216-001 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH

More information

Intel Retail Client Manager

Intel Retail Client Manager Intel Retail Client Manager Frequently Asked Questions June 2014 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO

More information

Intel Storage System SSR212CC Enclosure Management Software Installation Guide For Red Hat* Enterprise Linux

Intel Storage System SSR212CC Enclosure Management Software Installation Guide For Red Hat* Enterprise Linux Intel Storage System SSR212CC Enclosure Management Software Installation Guide For Red Hat* Enterprise Linux Order Number: D58855-002 Disclaimer Information in this document is provided in connection with

More information

Intel Simple Network Management Protocol (SNMP) Subagent v6.0

Intel Simple Network Management Protocol (SNMP) Subagent v6.0 Intel Simple Network Management Protocol (SNMP) Subagent v6.0 User Guide March 2013 ii Intel SNMP Subagent User s Guide Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL

More information

Intel vpro Technology. How To Purchase and Install Go Daddy* Certificates for Intel AMT Remote Setup and Configuration

Intel vpro Technology. How To Purchase and Install Go Daddy* Certificates for Intel AMT Remote Setup and Configuration Intel vpro Technology How To Purchase and Install Go Daddy* Certificates for Intel AMT Remote Setup and Configuration Revision 1.4 March 10, 2015 Revision History Revision Revision History Date 1.0 First

More information

Creating Overlay Networks Using Intel Ethernet Converged Network Adapters

Creating Overlay Networks Using Intel Ethernet Converged Network Adapters Creating Overlay Networks Using Intel Ethernet Converged Network Adapters Technical Brief Networking Division (ND) August 2013 Revision 1.0 LEGAL INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION

More information

Cloud.com CloudStack Community Edition 2.1 Beta Installation Guide

Cloud.com CloudStack Community Edition 2.1 Beta Installation Guide Cloud.com CloudStack Community Edition 2.1 Beta Installation Guide July 2010 1 Specifications are subject to change without notice. The Cloud.com logo, Cloud.com, Hypervisor Attached Storage, HAS, Hypervisor

More information

Cluster Configuration Manual Cluster configuration on Database Servers

Cluster Configuration Manual Cluster configuration on Database Servers Cluster configuration on Database Servers - 1 - Table of Contents 1. PREREQUISITES BEFORE SETTING UP CLUSTER... 3 2. INSTALLING CLUSTER PACKAGES... 3 3. CLUSTER CONFIGURATION... 4 3.1 CREATE NEW CONFIGURATION...

More information

Intel Retail Client Manager

Intel Retail Client Manager October 2014 By using this document, in addition to any agreements you have with Intel, you accept the terms set forth below. You may not use or facilitate the use of this document in connection with any

More information

Intel Matrix Storage Console

Intel Matrix Storage Console Intel Matrix Storage Console Reference Content January 2010 Revision 1.0 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE,

More information

User Experience Reference Design

User Experience Reference Design Use McAfee* Real Time Command and Intel SCS 9 to Manage Intel SSD Professional 1500 Series Drives Revision 1.1 July 2014 Document number: 330798-001 Revision History Revision Revision History Date 1.0

More information

Recovery BIOS Update Instructions for Intel Desktop Boards

Recovery BIOS Update Instructions for Intel Desktop Boards Recovery BIOS Update Instructions for Intel Desktop Boards All BIOS update files for Intel Desktop Boards are available on Intel's Download Center at http://downloadcenter.intel.com/. Important Notes:

More information

Intel Media SDK Library Distribution and Dispatching Process

Intel Media SDK Library Distribution and Dispatching Process Intel Media SDK Library Distribution and Dispatching Process Overview Dispatching Procedure Software Libraries Platform-Specific Libraries Legal Information Overview This document describes the Intel Media

More information

Intel Cloud Builder Guide: Cloud Design and Deployment on Intel Platforms

Intel Cloud Builder Guide: Cloud Design and Deployment on Intel Platforms EXECUTIVE SUMMARY Intel Cloud Builder Guide Intel Xeon Processor-based Servers Red Hat* Cloud Foundations Intel Cloud Builder Guide: Cloud Design and Deployment on Intel Platforms Red Hat* Cloud Foundations

More information

Intel HTML5 Development Environment. Article - Native Application Facebook* Integration

Intel HTML5 Development Environment. Article - Native Application Facebook* Integration Intel HTML5 Development Environment Article - Native Application Facebook* Integration V3.06 : 07.16.2013 Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO

More information

Intel Data Migration Software

Intel Data Migration Software User Guide April 2016 Software Version 3.0 Document Number: 324324-003US Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence

More information

Intel Matrix Storage Manager 8.x

Intel Matrix Storage Manager 8.x Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,

More information

Command Line Interface User Guide for Intel Server Management Software

Command Line Interface User Guide for Intel Server Management Software Command Line Interface User Guide for Intel Server Management Software Legal Information Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel

More information

SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System

SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System SyAM Software* Server Monitor Local/Central* on a Microsoft* Windows* Operating System with Internal Storage Focusing on IPMI Out of Band Management Recipe ID: 19SYAM190000000011-01 Contents Hardware Components...3

More information

McAfee Firewall Enterprise

McAfee Firewall Enterprise Hardware Guide Revision C McAfee Firewall Enterprise S1104, S2008, S3008 The McAfee Firewall Enterprise Hardware Product Guide describes the features and capabilities of appliance models S1104, S2008,

More information

ThinkServer RD540 and RD640 Operating System Installation Guide

ThinkServer RD540 and RD640 Operating System Installation Guide ThinkServer RD540 and RD640 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and

More information

Building Microsoft Windows Server 2012 Clusters on the Dell PowerEdge VRTX

Building Microsoft Windows Server 2012 Clusters on the Dell PowerEdge VRTX Building Microsoft Windows Server 2012 Clusters on the Dell PowerEdge VRTX Startup Guide Paul Marquardt Contents Introduction... 4 Requirements... 4 Chassis setup... 6 Chassis placement and CMC cabling...

More information

Installing Operating Systems

Installing Operating Systems CHAPTER 6 The unattended operating system installation function helps you install the Microsoft Windows and RedHat Linux operating system families. UCS-SCU has integrated device drivers including RAID

More information

VMware ESXi 5.0 Installation and RWC2 Tips and Tricks

VMware ESXi 5.0 Installation and RWC2 Tips and Tricks VMware ESXi 5.0 Installation and RWC2 Tips and Tricks This document introduces the details of how to install VMware ESXi 5.0 Operating System onto an Intel RAID controller and how to use Intel RAID Web

More information

Red Hat Network Satellite High Availability Guide By Wayman Smith, Red Hat Consultant

Red Hat Network Satellite High Availability Guide By Wayman Smith, Red Hat Consultant Red Hat Network Satellite High Availability Guide By Wayman Smith, Red Hat Consultant Red Hat Network (RHN) Satellite Server is an easy-to-use systems management platform for your growing Red Hat Enterprise

More information

Intel HTML5 Development Environment Article Using the App Dev Center

Intel HTML5 Development Environment Article Using the App Dev Center Intel HTML5 Development Environment Article Using the App Dev Center v1.06 : 06.04.2013 Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS

More information

Intel Management Engine BIOS Extension (Intel MEBX) User s Guide

Intel Management Engine BIOS Extension (Intel MEBX) User s Guide Intel Management Engine BIOS Extension (Intel MEBX) User s Guide User s Guide For systems based on Intel B75 Chipset August 2012 Revision 1.0 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH

More information

Intel Desktop Board D101GGC Specification Update

Intel Desktop Board D101GGC Specification Update Intel Desktop Board D101GGC Specification Update Release Date: November 2006 Order Number: D38925-003US The Intel Desktop Board D101GGC may contain design defects or errors known as errata, which may cause

More information

An Oracle White Paper June 2010. How to Install and Configure a Two-Node Cluster

An Oracle White Paper June 2010. How to Install and Configure a Two-Node Cluster An Oracle White Paper June 2010 How to Install and Configure a Two-Node Cluster Table of Contents Introduction... 3 Two-Node Cluster: Overview... 4 Prerequisites, Assumptions, and Defaults... 4 Configuration

More information

Intel HTML5 Development Environment. Tutorial Test & Submit a Microsoft Windows Phone 8* App (BETA)

Intel HTML5 Development Environment. Tutorial Test & Submit a Microsoft Windows Phone 8* App (BETA) Intel HTML5 Development Environment Tutorial Test & Submit a Microsoft Windows Phone 8* App v1.00 : 04.09.2013 Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS.

More information

ThinkServer RD550 and RD650 Operating System Installation Guide

ThinkServer RD550 and RD650 Operating System Installation Guide ThinkServer RD550 and RD650 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and

More information

Intel Rapid Storage Technology

Intel Rapid Storage Technology Intel Rapid Storage Technology User Guide August 2011 Revision 1.0 1 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,

More information

Novell Identity Manager Resource Kit

Novell Identity Manager Resource Kit AUTHORIZED DOCUMENTATION Installation Guide for SUSE Linux Enterprise Server 10 SP2 Novell Identity Manager Resource Kit 1.2 August 17, 2009 www.novell.com Identity Manager Resource Kit 1.2 Installation

More information

SUSE Manager in the Public Cloud. SUSE Manager Server in the Public Cloud

SUSE Manager in the Public Cloud. SUSE Manager Server in the Public Cloud SUSE Manager in the Public Cloud SUSE Manager Server in the Public Cloud Contents 1 Instance Requirements... 2 2 Setup... 3 3 Registration of Cloned Systems... 6 SUSE Manager delivers best-in-class Linux

More information

Syncplicity On-Premise Storage Connector

Syncplicity On-Premise Storage Connector Syncplicity On-Premise Storage Connector Implementation Guide Abstract This document explains how to install and configure the Syncplicity On-Premise Storage Connector. In addition, it also describes how

More information

Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008

Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008 Best Practices Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008 Installation and Configuration Guide 2010 LSI Corporation August 13, 2010

More information

Intel System Event Log (SEL) Viewer Utility

Intel System Event Log (SEL) Viewer Utility Intel System Event Log (SEL) Viewer Utility User Guide Document No. E12461-007 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE GENERAL PURPOSE OF SUPPORTING

More information

Intel Server Raid Controller. RAID Configuration Utility (RCU)

Intel Server Raid Controller. RAID Configuration Utility (RCU) Intel Server Raid Controller RAID Configuration Utility (RCU) Revision 1.1 July 2000 Revision History Date Rev Modifications 02/13/00 1.0 Initial Release 07/20/00 1.1 Update to include general instructions

More information

Intel Small Business Advantage (Intel SBA) Release Notes for OEMs

Intel Small Business Advantage (Intel SBA) Release Notes for OEMs Intel Small Business Advantage (Intel SBA) Release Notes for OEMs Document Release Date: October 16, 2015 Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO

More information

Intel Data Direct I/O Technology (Intel DDIO): A Primer >

Intel Data Direct I/O Technology (Intel DDIO): A Primer > Intel Data Direct I/O Technology (Intel DDIO): A Primer > Technical Brief February 2012 Revision 1.0 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,

More information

NovaScale Blade 2GB Brocade SAN Switch Module (BBRM)

NovaScale Blade 2GB Brocade SAN Switch Module (BBRM) NovaScale Blade 2 GB Brocade Enterprise SAN Switch Module NovaScale Blade 2 GB Brocade Entry SAN Switch Module Release Notes Disclaimer Information in this document is provided in connection with Bull

More information

Intel Active Management Technology Embedded Host-based Configuration in Intelligent Systems

Intel Active Management Technology Embedded Host-based Configuration in Intelligent Systems WHITE PAPER Intel vpro Technology Embedded Host-based Configuration in Intelligent Systems Easy activation of Intel vpro technology remote manageability without trade-offs in security, functionality, and

More information

COSBench: A benchmark Tool for Cloud Object Storage Services. Jiangang.Duan@intel.com 2012.10

COSBench: A benchmark Tool for Cloud Object Storage Services. Jiangang.Duan@intel.com 2012.10 COSBench: A benchmark Tool for Cloud Object Storage Services Jiangang.Duan@intel.com 2012.10 Updated June 2012 Self introduction COSBench Introduction Agenda Case Study to evaluate OpenStack* swift performance

More information

Intel Service Assurance Administrator. Product Overview

Intel Service Assurance Administrator. Product Overview Intel Service Assurance Administrator Product Overview Running Enterprise Workloads in the Cloud Enterprise IT wants to Start a private cloud initiative to service internal enterprise customers Find an

More information

ASM_readme_6_10_18451.txt -------------------------------------------------------------------- README.TXT

ASM_readme_6_10_18451.txt -------------------------------------------------------------------- README.TXT README.TXT Adaptec Storage Manager (ASM) as of June 3, 2009 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.

More information

with PKI Use Case Guide

with PKI Use Case Guide Intel Identity Protection Technology (Intel IPT) with PKI Use Case Guide Version 1.0 Document Release Date: February 29, 2012 Intel IPT with PKI Use Case Guide i Legal Notices and Disclaimers INFORMATION

More information

Using Red Hat Network Satellite Server to Manage Dell PowerEdge Servers

Using Red Hat Network Satellite Server to Manage Dell PowerEdge Servers Using Red Hat Network Satellite Server to Manage Dell PowerEdge Servers Enterprise Product Group (EPG) Dell White Paper By Todd Muirhead and Peter Lillian July 2004 Contents Executive Summary... 3 Introduction...

More information

Intel System Event Log (SEL) Viewer Utility

Intel System Event Log (SEL) Viewer Utility Intel System Event Log (SEL) Viewer Utility User Guide Document No. E12461-005 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE GENERAL PURPOSE OF SUPPORTING

More information

Acronis Backup & Recovery 11.5 Quick Start Guide

Acronis Backup & Recovery 11.5 Quick Start Guide Acronis Backup & Recovery 11.5 Quick Start Guide Applies to the following editions: Advanced Server for Windows Virtual Edition Advanced Server SBS Edition Advanced Workstation Server for Linux Server

More information

LSI MegaRAID User s Manual

LSI MegaRAID User s Manual LSI MegaRAID User s Manual Q2143 August 2005 Copyright Information No part of this manual, including the products and software described in it,may be reproduced, transmitted, transcribed, stored in a retrieval

More information

Using Symantec NetBackup with Symantec Security Information Manager 4.5

Using Symantec NetBackup with Symantec Security Information Manager 4.5 Using Symantec NetBackup with Symantec Security Information Manager 4.5 Using Symantec NetBackup with Symantec Security Information Manager Legal Notice Copyright 2007 Symantec Corporation. All rights

More information

Intel Compute Stick STCK1A32WFC User Guide. Intel Compute Stick STCK1A32WFC

Intel Compute Stick STCK1A32WFC User Guide. Intel Compute Stick STCK1A32WFC Intel Compute Stick STCK1A32WFC User Guide 1 Revision History Revision Revisions History Date 01 First release of the Intel Compute Stick STCK1A32WFC User Guide April 2015 Disclaimer INFORMATION IN THIS

More information

Intel Server Board Platform Confidence Test Installation and Operating Instructions

Intel Server Board Platform Confidence Test Installation and Operating Instructions Intel Server Board Platform Confidence Test Installation and Operating Instructions i Intel Corporation 2002-2009 Information in this document is provided in connection with Intel products. No license,

More information

Installing and Configuring the Intel Server Manager 8 SNMP Subagents. Intel Server Manager 8.40

Installing and Configuring the Intel Server Manager 8 SNMP Subagents. Intel Server Manager 8.40 Installing and Configuring the Intel Server Manager 8 SNMP Subagents Intel Server Manager 8.40 Legal Information This Installing and Configuring the Intel Server Manager 8 SNMP Subagents--Intel Server

More information

Installing the Operating System or Hypervisor

Installing the Operating System or Hypervisor Installing the Operating System or Hypervisor If you purchased E-Series Server Option 1 (E-Series Server without preinstalled operating system or hypervisor), you must install an operating system or hypervisor.

More information

Yosemite Server Backup Installation Guide

Yosemite Server Backup Installation Guide Yosemite Server Backup Installation Guide Part number: First edition: October, 2010 Legal and notice information Copyright 2004, 2012 Barracuda Networks, Inc. Under copyright laws, the contents of this

More information

Revision History. Revision Revision History Date

Revision History. Revision Revision History Date G001 Revision History Revision Revision History Date 1.0 First release of the Intel NUC Home Theatre Personal Computer on the Linux* Mint Platform using XBMC May 2013 2.0 Second release of the Intel NUC

More information

Intel Remote Configuration Certificate Utility Frequently Asked Questions

Intel Remote Configuration Certificate Utility Frequently Asked Questions Intel Remote Configuration Certificate Utility Frequently Asked Questions General Info 1. What operating system do I have to use to run the wizard? 2. What configurations are required prior to running

More information

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the software, please review the readme files,

More information

Intel One Boot Flash Update Utility

Intel One Boot Flash Update Utility Intel One Boot Flash Update Utility User Guide February 2012 Document Number: E71543-005 Legal Statements INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS FOR THE PURPOSE OF SUPPORTING

More information

User Guide Software Version 2.1.0

User Guide Software Version 2.1.0 Intel Solid State Drive Firmware Update Tool User Guide Software Version 2.1.0 Order Number: 322570-007US Intel disclaims all express and implied warranties, including without limitation, the implied warranties

More information

Dell One Identity Cloud Access Manager 8.0.1- How to Configure for High Availability

Dell One Identity Cloud Access Manager 8.0.1- How to Configure for High Availability Dell One Identity Cloud Access Manager 8.0.1- How to Configure for High Availability May 2015 Cloning the database Cloning the STS host Cloning the proxy host This guide describes how to extend a typical

More information

System Image Recovery* Training Foils

System Image Recovery* Training Foils Intel-powered Classmate PC System Image Recovery* Training Foils Version 1.0 1 *Other names and brands may be claimed as the property of others. Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED

More information

IBM Endpoint Manager Version 9.1. Patch Management for Red Hat Enterprise Linux User's Guide

IBM Endpoint Manager Version 9.1. Patch Management for Red Hat Enterprise Linux User's Guide IBM Endpoint Manager Version 9.1 Patch Management for Red Hat Enterprise Linux User's Guide IBM Endpoint Manager Version 9.1 Patch Management for Red Hat Enterprise Linux User's Guide Note Before using

More information

Intel RAID Controller Troubleshooting Guide

Intel RAID Controller Troubleshooting Guide Intel RAID Controller Troubleshooting Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Intel order number C18781-001 September 2, 2002 Revision History Troubleshooting

More information

ThinkServer RD350 and RD450 Operating System Installation Guide

ThinkServer RD350 and RD450 Operating System Installation Guide ThinkServer RD350 and RD450 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and

More information

The Case for Rack Scale Architecture

The Case for Rack Scale Architecture The Case for Rack Scale Architecture An introduction to the next generation of Software Defined Infrastructure Intel Data Center Group Pooled System Top of Rack Switch POD Manager Network CPU/Memory Storage

More information

Dell One Identity Cloud Access Manager 7.0.2. Installation Guide

Dell One Identity Cloud Access Manager 7.0.2. Installation Guide Dell One Identity Cloud Access Manager 7.0.2 2014 Dell Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide is furnished under

More information

INUVIKA OVD INSTALLING INUVIKA OVD ON RHEL 6

INUVIKA OVD INSTALLING INUVIKA OVD ON RHEL 6 INUVIKA OVD INSTALLING INUVIKA OVD ON RHEL 6 Mathieu SCHIRES Version: 0.96.1 Published January 19, 2015 http://www.inuvika.com Contents 1 Prerequisites: RHEL 6 3 1.1 System Requirements...................................

More information

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices White Paper April 2012 Document: 327216-001 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,

More information

Intel RAID Volume Recovery Procedures

Intel RAID Volume Recovery Procedures Intel RAID Volume Recovery Procedures Revision 1.0 12/20/01 Revision History Date Revision Number 12/20/01 1.0 Release Modifications Disclaimers Information in this document is provided in connection with

More information

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Release 3.0 User Guide P/N 300-999-671 REV 02 Copyright 2007-2013 EMC Corporation. All rights reserved. Published in the USA.

More information

-------------------------------------------------------------------- README.TXT

-------------------------------------------------------------------- README.TXT README.TXT Adaptec Storage Manager (ASM) as of September 17, 2007 Please review this file for important information about issues and erratas that were discovered after completion of the standard product

More information

Parallels Cloud Server 6.0

Parallels Cloud Server 6.0 Parallels Cloud Server 6.0 Getting Started Guide March 17, 2015 Copyright 1999-2015 Parallels IP Holdings GmbH and its affiliates. All rights reserved. Parallels IP Holdings GmbH Vordergasse 59 8200 Schaffhausen

More information

Intel Solid-State Drive Data Center Tool User Guide Version 1.1

Intel Solid-State Drive Data Center Tool User Guide Version 1.1 Intel Solid-State Drive Data Center Tool User Guide Version 1.1 Order Number: 327191-002 October 2012 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR

More information

PostgreSQL Clustering with Red Hat Cluster Suite

PostgreSQL Clustering with Red Hat Cluster Suite PostgreSQL Clustering with Red Hat Cluster Suite Devrim GÜNDÜZ PostgreSQL Contributor Twitter: @DevrimGunduz Red Hat Certified Engineer Community: devrim@postgresql.org Personal: devrim@gunduz.org Before

More information

By the Citrix Publications Department. Citrix Systems, Inc.

By the Citrix Publications Department. Citrix Systems, Inc. Licensing: Setting Up the License Server on a Microsoft Cluster By the Citrix Publications Department Citrix Systems, Inc. Notice The information in this publication is subject to change without notice.

More information

RSA Security Analytics. S4 Broker Setup Guide

RSA Security Analytics. S4 Broker Setup Guide RSA Security Analytics S4 Broker Setup Guide Copyright 2010-2013 RSA, the Security Division of EMC. All rights reserved. Trademarks RSA, the RSA Logo and EMC are either registered trademarks or trademarks

More information

How To Install Acronis Backup & Recovery 11.5 On A Linux Computer

How To Install Acronis Backup & Recovery 11.5 On A Linux Computer Acronis Backup & Recovery 11.5 Server for Linux Update 2 Installation Guide Copyright Statement Copyright Acronis International GmbH, 2002-2013. All rights reserved. Acronis and Acronis Secure Zone are

More information

OnCommand Performance Manager 1.1

OnCommand Performance Manager 1.1 OnCommand Performance Manager 1.1 Installation and Setup Guide For Red Hat Enterprise Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

White Paper. Fabasoft on Linux Cluster Support. Fabasoft Folio 2015 Update Rollup 2

White Paper. Fabasoft on Linux Cluster Support. Fabasoft Folio 2015 Update Rollup 2 White Paper Fabasoft Folio 2015 Update Rollup 2 Copyright Fabasoft R&D GmbH, Linz, Austria, 2015. All rights reserved. All hardware and software names used are registered trade names and/or registered

More information