Comparison of space analysis performed on plaster vs. digital dental casts applying Tanaka and Johnston s equation
|
|
|
- Lauren Little
- 9 years ago
- Views:
Transcription
1 original article Comparison of space analysis performed on plaster vs. digital dental casts applying Tanaka and Johnston s equation Júlia Olien Sanches 1, Lourdes Aparecida Martins dos Santos-Pinto 2, Ary dos Santos-Pinto 3, Betina Grehs 1, Fabiano Jeremias 4 Objective: The purpose of this study was to compare dental size measurements, their reproducibility and the application of Tanaka and Johnston regression equation in predicting the size of canines and premolars on plaster and digital dental casts. Methods: Thirty plaster casts were scanned and digitized. Mesiodistal measurements of the teeth were then performed with a digital caliper on the plaster and digital casts using O3d software system (Widialabs ).The sum of the sizes of the lower incisors was used to obtain predictive values of the sizes of the premolars and canines using the regression equation, and these values were compared with the actual sizes of the teeth. The data were statistically analyzed by applying to the results Pearson s correlation test, Dahlberg s formula, paired t-test and analysis of variance (p<0.05). Results: Excellent intraexaminer agreement was observed in the measurements performed on both dental casts. No random error was present in the measurements obtained with the caliper and systematic error (bias) was more frequent in the digital casts. Space prediction obtained by applying the regression equation was greater than the sum of the canines and premolars on the plaster and digital casts. Conclusions: Despite an adequate reproducibility of the measurements performed on both casts, most measurements on the digital casts were higher than those on the plaster casts. The predicted space was overestimated in both models and significantly higher in the digital casts. Keywords: Three-dimensional image. Dental casts. Test reproducibility. Objetivo: comparar medidas de tamanhos dentários, suas reprodutibilidades e a aplicação da equação de regressão de Tanaka e Johnston na predição do tamanho dos caninos e pré-molares em modelos de gesso e digital. Métodos: trinta modelos de gesso foram escaneados para obtenção dos modelos digitais. As medidas do comprimento mesiodistal dos dentes foram obtidas com paquímetro digital nos modelos de gesso e nos modelos digitais utilizando o software O3d (Widialabs). A somatória do tamanho dos incisivos inferiores foi utilizada para obter os valores de predição do tamanho dos pré-molares e caninos utilizando equação de regressão, e esses valores foram comparados ao tamanho real dos dentes. Os dados foram analisados estatisticamente, aplicando-se aos resultados o teste de correlação de Pearson, a fórmula de Dahlberg, o teste t pareado e a análise de variância (p < 0,05). Resultados: excelente concordância intraexaminador foi observada nas medidas realizadas em ambos os modelos. O erro aleatório não esteve presente nas medidas obtidas com paquímetro, e o erro sistemático foi mais frequente no modelo digital. A previsão de espaço obtida pela aplicação da equação de regressão foi maior que a somatória dos pré-molares e caninos presentes nos modelos de gesso e nos modelos digitais. Conclusão: apesar da boa reprodutibilidade das medidas realizadas em ambos os modelos, a maioria das medidas dos modelos digitais foram superiores às do modelos de gesso. O espaço previsto foi superestimado em ambos os modelos e significativamente maior nos modelos digitais. Palavras-chave: Imagem Tridimensional. Modelos dentários. Reprodutibilidade dos testes. 1 Undergraduate student, Araraquara Dental School, São Paulo State University (UNESP). 2 Full Professor, Children s Clinic Department, Araraquara Dental School (UNESP). 3 Associate Professor, Children s Clinic Department, Araraquara Dental School (UNESP). 4 Graduate student, Araraquara Dental School (UNESP). Submitted: September 28, Revised and accepted: November 08, 2011 How to cite this article: Sanches JO, Santos-Pinto LAM, Santos-Pinto A, Grehs B, Jeremias F. Comparison of space analysis performed on plaster vs. digital dental casts applying Tanaka and Johnston s equation. Dental Press J Orthod Jan-Feb;18(1): » The authors report no commercial, proprietary or financial interest in the products or companies described in this article. Contact address: Lourdes Aparecida Martins dos Santos-Pinto Rua Humaitá, 1680 Araraquara/SP CEP: [email protected] 2013 Dental Press Journal of Orthodontics 128
2 Sanches JO, Santos-Pinto LAM, Santos-Pinto A, Grehs B, Jeremias F original article introduction Determining the mesiodistal size of unerupted permanent teeth is an important procedure in the diagnosis and treatment planning of patients in the mixed dentition as it is instrumental in predicting the required space in the dental arch where the teeth usually canines and premolars will be positioned. Some methods use the adequate correlation found between the width of the permanent lower incisors and unerupted canines and premolars to predict space in mixed dentition. One such example is Moyer s analysis. 1 Space prediction in mixed dentition can also be carried out using regression equations for each side of the upper [Y = (X)] and lower [Y = (X)] dental arches, where Y is the sum of the unerupted canines and premolars and X the sum of the four unerupted permanent incisors. 2 This analysis is considered one of the most practical for clinical use as it requires no x-rays or tables to predict the size of the teeth. 1 Traditionally, these diagnostic tests have been performed on plaster casts, where one can (a) assess the occlusal relationships of patients without interfering with soft tissues, (b) determine the issues to be addressed and (c) define which orthodontic mechanics will be applied. However, some of the disadvantages inherent in the use of plaster casts 3,4 are their weight and volume, time spent on their fabrication, the need for a physical storage space, the risk of breakage and difficulty in exchanging information with other professionals. Currently, digital casts offer orthodontists a convenient alternative to routine plaster casts. Their greater attractiveness is related to the speed to store patient diagnoses in a computer, instant accessibility and convenient sharing of information with colleagues. 5 A variety of methods have been developed to digitize plaster casts. Digitization is performed on casts or alginate impressions with the aid of a scanner or digital camera. The software used can electronically store the images and perform three-dimensional measurements. 4,6,7 Digital casts can be overviewed in a 360º view, in all planes of space, and can also be viewed singly, i.e., only the upper or only the lower dental arch. 5 Most digital image analysis software available on the market are not developed in Brazil, which results in high costs since patient impressions or plaster casts must be shipped overseas for scanning. O3d is a software system developed by Widialabs (Goiânia, Brazil), a pioneering Brazilian company in the development of technologies geared to the digitization and analysis of dental casts for use in orthodontics. Orthodontists can access their digitized casts on the company s website, download these data to their computer and perform measurements and analyses. Recent studies show that measurements of dental arch sizes, arch width, overjet and overbite on digital models are valid and can be reproduced. 8,9 Measuring tooth size on the arch itself is influenced by several factors such as tooth inclination, rotation, proximal contact, anatomical variations and interexaminer variability. Thus, the accuracy and reliability of these software need to be evaluated prior to clinical implementation. 10 Within the context outlined above, the aim of this study was to compare the measurements of dental sizes, their reproducibility and prediction of the sizes of the upper and lower canines and premolars by applying Tanaka and Johnston s 2 regression equation on plaster dental casts and digital models. Material and Methods After approval by the Ethics Committee of Araraquara Dental School (UNESP) (Protocol #33/07) thirty plaster casts were selected from the diagnostic records of patients that were receiving treatment with fixed appliances. All casts were scanned in the Orthodontic Records Service (SDO) in Araraquara, São Paulo State, and standardized by the same professional. The criteria for inclusion of plaster casts in the study were: Presence of incisors, canines, premolars and permanent first molars in both the maxillary and mandibular arches; all cast teeth showing normal morphology; absence of irregularities in the plaster caused by carious lesions and restorations, which might affect the mesiodistal or buccolingual diameter of dental crowns; no prior orthodontic treatment. The models were replicated to prevent damage to the patient records. The impressions were taken by the same professional using plastic trays (Morelli Orthodontics, Sorocaba, SP, Brazil) and alginate (Jeltrate, Dentsply, Petrópolis, RJ, Brazil).The casts were fabricated with special dental stone (Durone V, Dentsply, Petrópolis, RJ, Brazil) vacuum mixed at a ratio of 19 ml water to 100 g of powder and poured onto a vibrator to decrease the likelihood of bubbles. Two casts were used as standard and had 12 points marked on their upper arch and 20 points on their 2013 Dental Press Journal of Orthodontics 129
3 original article Comparison of space analysis performed on plaster vs. digital dental casts applying Tanaka and Johnston s equation lower arch as reference for the largest mesiodistal diameter of the crowns of the maxillary and mandibular canines and premolars, and mandibular incisors. Ten casts were randomly selected to be measured with a digital caliper (Mitutoyo Digimatic, Mitutoyo Ltd., Suzano, SP, Brazil). The measurements were repeated within a one-week interval for examiner calibration. Reliability of the variable measuring process was evaluated by Pearson s correlation coefficient, which was After calibration, the measurements reflecting the greatest distance between the mesial and distal surfaces of crowns of all mandibular teeth and of all maxillary canines and premolars were obtained using a digital caliper. In the posterior teeth, these distances were obtained with an occlusal view of the model, and in anterior teeth, with a labial view. Once the measurements with the digital caliper were completed, the models were forwarded for non-destructive laser scanning, with the reading done by surface scanning using a R-700 Orthodontic 3D Scanner (Copenhagen, Denmark) without touching the cast, and with an accuracy of in and 400 dots per inch (DPI). Using O3d software (Widialabs, Goiânia, Brazil) with three-dimensional images, measurements were carried out by drawing a transverse line across the largest mesiodistal width of the posterior teeth examined in occlusal view and labial view of the anterior teeth as described in the literature. 6,9,11,12 Teeth prediction values calculated by applying Tanaka and Johnston s 2 regression equation were compared to the actual sizes of maxillary and mandibular premolars and canines measured directly on the plaster models and three-dimensional images. All measurements were repeated within a one-week interval to test intraexaminer reliability, confirmed by Pearson s correlation test. Dahlberg s formula was applied to estimate the magnitude of casual errors and the paired t-test was applied to identify systematic errors, according to Houston. 13 The difference between the measurements obtained in the plaster vs. digital casts was evaluated by means of analysis of variance at a 5% significance level (p<0.05). Results Assessment of intraexaminer reliability was performed for all dental measurements and in all models, yielding an excellent correlation between the first and second measurements performed both using a caliper on the plaster casts and the O3d software system on digital models. Application of Dahlberg s formula showed no random error in measurements performed with a caliper on the plaster casts. Systematic error was found only in the measurements of teeth 24 and 43, which showed a difference of one hundredth of a millimeter (-0.06 and mm, respectively), considered clinically insignificant. The measurements carried out on digital casts using the O3d System showed random error in teeth 13, 23 and 33. In assessing systematic error statistical differences occurred in measuring teeth 13, 14, 15, 23, 33, 35, 43 and 44 (Table 1). In comparing the measuring instruments it was noted that the mesiodistal measurements of teeth 13, 14, 23, 33 and 35 were statistically significantly higher for measurements carried out by the O3d software system compared with a digital caliper (Table 1). The values for required space obtained by applying the regression equation were larger than the sum of the measurements of the premolars and canines on the plaster casts (mean of 3.35 mm for the maxillary arch and 2.84 mm for the mandibular arch, and digital casts (mean of 1.11 mm for the maxillary arch and 0.72 mm for the mandibular arch). Statistically significant differences were found in the measurements performed in all segments of the dental arch (Table 2). Discussion The measurements of dental sizes obtained both by caliper and by the O3d system presented excellent intraexaminer reliability, established by the correlation (r), which ranged from 0.87 to 0.99 for the caliper and 0.96 to 0.99 for the O3d System (Table 1). A similar intraexaminer reliability found for both the plaster and digital casts was reported by Quimby et al 8. However, Dalstra and Melsen 14, after measuring the maxillary right central incisor and first molar on the right side, reported that the intraexaminer variation was lower for the measurements performed on digital casts. Moreover, El-Zanaty et al 15 found little correlation between the two methods and attributed the error to (a) difficulties in accurately identifying the contact points and (b) lack of experience of the examiner to conduct measurements on three-dimensional computer images. Random error was not noted in the measurements performed with a caliper Dental Press Journal of Orthodontics 130
4 Sanches JO, Santos-Pinto LAM, Santos-Pinto A, Grehs B, Jeremias F original article Table 1 - Means, standard deviations (SD) and differences (dif) between the first and second mesiodistal measurements of the teeth, in millimeters. Random error (Dahlberg s Formula), systematic error (p<0.05), correlation (r) obtained from plaster and digital casts and comparison between methods (ANOVA: p<0.05). Teeth Caliper O3d Caliper * Statistical significance. mean SD dif. Dahlberg p r mean SD dif. Dahlberg p r dif. ANOVA * * * * * * * * * * * * * Table 2 - Measurement values (mm) of the required space (RS) obtained by Tanaka and Johnston s regression equation, existing space (ES), difference between the two (RS-ES) and comparison between the methods (Anova: p<0.05). Arch Measurements Side Caliper O3d Caliper mean SD mean SD dif. ANOVA RS Right * ES * Superior RS-ES * ES Left * RS-ES * RS * ES Right * Inferior RS-ES * ES Left * RS-ES * * Statistical significance. However, in the measurements carried out with the O3d System, random error was found in teeth 13, 23 and 33, which can be explained by a difficulty in determining the angle between the proximal surfaces and the cusps as reference for the largest mesiodistal diameter in three-dimensional images. The mean value of the differences observed between the first and second measurement of the size of the teeth ranged from 0.00 to 0.06 mm on the plaster casts and from 0.01 to 0.20 mm on the digital casts (Table 1). These values have no clinical relevance as they are below the acceptable values, i.e., 0.20 mm 16 or 30 mm. 17 Despite the excellent intraexaminer reliability of the measurements carried out with the O3d system, systematic error was present in teeth 13, 14, 15, 23, 33, 35 and 43. The error found in the canines was 2013 Dental Press Journal of Orthodontics 131
5 original article Comparison of space analysis performed on plaster vs. digital dental casts applying Tanaka and Johnston s equation probably due to the position of these teeth, i.e., on the curvature of the dental arch, thereby hindering the movement of the digitized model in the program and the identification of reference points used to perform the measurements. While performing the measurements, it was noted that the tool used to locate the first reference point was similar to an arrowhead while the second point was defined by a tool shaped like a filled circle, which is less accurate. The points are important in setting the distance that must be measured by the program, which may have affected the measurements of the premolars. In comparing the measurements obtained with the two instruments, digital caliper and O3d System, it was observed that the values yielded by the latter were higher for all teeth except teeth 31, 41 and 42, where the difference between measurements was very low, ranging from 0.06 to 0.21 mm. The results of this study do not corroborate the findings of Santoro et al 6 and Dalstra and Melsen, 14 who found higher values for the teeth measured with the caliper, and Aguiar and Freitas 18 and Redlich et al, 12 in whose research the tooth sizes were underestimated for both dental arches in the measurements performed on digital casts. Keating et al 3 and Jedlinska 19 reported that the measurements obtained with a digital caliper on plaster and digital casts were similar. In applying Tanaka and Johnston s regression equations to each side of the maxillary arch [Y= (X)] and mandibular arch [Y= (X)] using the sum of the four erupted permanent mandibular incisors (X) to predict the sum of the non-erupted canines and premolars(y), it was noted that the predicted spaces were larger than the spaces actually present in the arches. A statistically significant difference was observed in all segments of both arches. Due to the fact that the measurements performed on the digital casts yielded larger values than the measurements obtained from the plaster casts, the difference found by the O3d System between the required space and the existing space were lower than those obtained by the caliper. Thus, in both the plaster and digital casts, the space predicted by Tanaka and Johnston s equation overestimated the size of the premolars and canines in both arches, corroborating the findings of Bishara and Jakobsen, 20 niktahere et al, 21 Arslan et al, 22 and unlike Melgaço et al, 23 who found underestimated values, although with no clinical significance. The measurements obtained from the digital casts in this study were reproducible, although some difficulties were encountered during measuring. The viewing of contact points, the excessive brightness in the models, the determination of reference points with the locating tool in the shape of a filled circle and the frequent failure in saving the data are some of the issues that need to be addressed by those who use the digital measurement analysis. This measuring instrument proved to be a promising tool in the analysis of dental casts. The system, however, calls for improvement while professionals must be trained to ensure proper use. Conclusions Based on the method employed in this study, one can conclude that dental size measurements showed good reproducibility in both plaster and digital casts. However, the measurements taken by the O3d software system proved superior to those obtained by caliper, and Tanaka and Johnston s equation 2 overestimated the sizes of premolar and canine teeth in the maxillary and mandibular arches with both measurement instruments Dental Press Journal of Orthodontics 132
6 Sanches JO, Santos-Pinto LAM, Santos-Pinto A, Grehs B, Jeremias F original article ReferEncEs 1. Alhaija ESJ, Qudeimat, MA. Mixed dentition space analysis in a Jordanian population: comparison of two methods. Int J Paediatr Dent. 2006;16(2): Tanaka MM, Johnston LE. The prediction of the size of unerupted canines and premolars in a contemporary orthodontic population. J Am Dent Assoc. 1974;88(4): Keating AP, Knox J, Bibb R, Zhurov AI. A comparison of plaster, digital and reconstructed study model accuracy. J Orthod. 2008;35(3): Redmond WR. Digital models: a new diagnostic tool. J Clin Orthod. 2001;35(6): Paredes V, Gandia JL, Cibrián R. Digital diagnosis records in orthodontics. An overview. Med Oral Patol Oral Cir Bucal. 2006;11(1):e Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ. Comparison of measurements made on digital and plaster models. Am J Orthod Dentofacial Orthop. 2003;124(1): Whetten JL, Williamson PC, Heo G, Varnhagen C, Major PW. Variations in orthodontic treatment planning decisions of Class II patients between virtual 3-dimensional models and traditional plaster study models. Am J Orthod Dentofacial Orthop. 2006;130(4): Quimby ML, Vig KW, Rashid GR, Firestone AR. The accuracy and reliability of measurements made on computer-based digital models. Angle Orthod. 2004;74(3): Zilberman O, Huggare JA, Parikakis KA. Evaluation of the validity of tooth size and arch width measurements using conventional and threedimensional virtual orthodontic models. Angle Orthod. 2003;73(3): Leifert MF, Leifert MM, Efstratiadis SS, Cangialosi TJ. Comparison of space analysis evaluations with digital models and plaster dental casts. Am J Orthod Dentofacial Orthop. 2009;136(1):16.e Mayers M, Firestone AR, Rashid R, Vig KW. Comparison of peer assessment rating (PAR) index scores of plaster and computer-based digital models. Am J Orthod Dentofacial Orthop. 2005;128(4): Redlich M, Weinstock T, Abed Y, Schneor R, Holdstein Y, Fischer A. A new system for scanning, measuring and analyzing dental casts based on a 3D holographic sensor. Orthod Craniofac Res. 2008;11(2): Houston WJB. The analysis of error in orthodontics measurements. Am J Orthod. 1983;83(5): Dalstra M, Melsen B. From alginate impression to digital virtual models: accuracy and reproducibility. J Orthod. 2009;36(1): El-Zanaty HM, El-Beialy AR, Abou El-Ezz AM, Attia KH, El-Bialy AR, Mostafa YA. Three-dimensional dental measurements: an alternative to plaster models. Am J Orthod Dentofacial Orthop. 2010;137(2): Schirmer UR, Wiltshire WA. Manual and computer-aided apace analysis: a comparative study. Am J Orthod Dentofacial Orthop. 1997;112(6): Hirogaki Y, Sohmura T, Satoh H, Takahashi J, Takada K. Complete 3-D reconstruction of dental cast shape using perceptual grouping. IEEE Trans Med Imaging. 2001;20(10): Aguiar RM, Freitas BV. Confiabilidade da análise de Moyers em indivíduos de São Luís-MA. Ortho Sci Orthod Sci Pract. 2008;1(2): Jedlinska A. The comparison analysis of the line measurements between plaster and virtual orthodontic 3D models. Ann Acad Med Stetin. 2008;54(2): Bishara SE, Jakobson JR. Comparison of two non radiographic methods of predicting permanent tooth size in the mixed dentition. Am J Orthod Dentofacial Orthop. 1998;114(5): niktahere H, Majid S, Fateme M, Kharazi F, Javad M. Predicting the size of unerupted canines and premolars of the maxillary and mandibular quadrants in an Iranian population. J Clin Pediatr Dent. 2007;32(1): Arslan SG, Dildes, N, Kama JD, Genc C. Mixed-dentition analysis in a Turkish population. World J Orthod. 2009;10(2): Melgaço CA, Araújo MT, Ruellas AC. Applicability of three tooth size prediction methods for white Brasilians. Angle Orthod. 2006;76(4): Dental Press Journal of Orthodontics 133
Accuracy of space analysis with emodels and plaster models
ORIGINAL ARTICLE Accuracy of space analysis with emodels and plaster models S. Russell Mullen, a Chris A. Martin, b Peter Ngan, c and Marcia Gladwin d Leesburg, Va, and Morgantown, WVa Introduction: The
Specific dimensional relationships must exist between
ORIGINAL ARTICLE Intermaxillary tooth size discrepancy and mesiodistal crown dimensions for a Turkish population Tancan Uysal a and Zafer Sari b Kayseri and Konya, Turkey Introduction: The aims of this
The American Board of Orthodontics (ABO) Digital Model Requirements Original Release 04.23.2013 Last Update 03.26.2015
Page 1 of 7 The American Board of Orthodontics (ABO) Digital Model Requirements Original Release 04.23.2013 Last Update 03.26.2015 Introduction In order to provide access to board certification for all
Relative position of gingival zenith in maxillary anterior teeth- a clinical appraisal
Original article: Relative position of gingival zenith in maxillary anterior teeth- a clinical appraisal 1Dr Dipti Shah, 2 Dr Kalpesh Vaishnav, 3 Dr Sareen Duseja, 4 Dr Pankti Agrawal 1HOD, Dept of Prosthodontics,
Accuracy of Ortho Insight 3D Digital Scanner in Mesial-Distal Tooth Measurements
Loma Linda University TheScholarsRepository@LLU: Digital Archive of Research, Scholarship & Creative Works Loma Linda University Electronic Theses & Dissertations 8-1-2012 Accuracy of Ortho Insight 3D
OVERJET AND OVERBITE ANALYSIS DURING THE ERUPTION OF THE UPPER PERMANENT INCISORS
221 OVERJET AND OVERBITE ANALYSIS DURING THE ERUPTION OF THE UPPER PERMANENT INCISORS Osmar A. Cuoghi, Rodrigo C. Sella, Igo Mamede, Fernanda A. de Macedo, Yésselin M. Miranda-Zamalloa, Marcos R. de Mendonça
Sexual Dimorphism in the Tooth-Crown Diameters of the Deciduous Teeth
Sexual Dimorphism in the Tooth-Crown Diameters of the Deciduous Teeth THOMAS K. BLACK 111 Museum ofanthropology, The university of Michigan, Ann Arbor, Michigan 48109 KEY WORDS Deciduous dentition criminant
Maxillary canine palatal impaction occurs in 1
ORIGINAL ARTICLE Prediction of maxillary canine impaction using sectors and angular measurement John H. Warford Jr, DDS, a,b Ram K. Grandhi, BDS, Dip Perio, Cert Ortho, MS, b and Daniel E. Tira, PhD c
In the past decade, there has been a remarkable
TECHNO BYTES Principles of cosmetic dentistry in orthodontics: Part 1. Shape and proportionality of anterior teeth David M. Sarver, DMD, MS Vestavia Hills, Ala In the past decade, there has been a remarkable
SYSTEMATIC APPROACH TO ORTHODONTIC DIAGNOSIS DENT 656
SYSTEMATIC APPROACH TO ORTHODONTIC DIAGNOSIS DENT 656 ORTHODONTIC CLASSIFICATION / DIAGNOSIS Goal of diagnosis: An orderly reduction of the data base to a useful list of the patient s problems Useful??
Efficiency of Three Mandibular Anchorage Forms in Herbst Treatment: A Cephalometric Investigation
Original Article Efficiency of Three Mandibular Anchorage Forms in Herbst Treatment: A Cephalometric Investigation Dominique Weschler, DDS, Dr Med Dent a ; Hans Pancherz, DDS, Odont Dr, FCDSHK (Hon) b
Control of mandibular incisors with the combined Herbst and completely customized lingual appliance - a pilot study
Control of mandibular incisors with the combined Herbst and completely customized lingual appliance - a pilot study Dirk Wiechmann 1 *, Rainer Schwestka-Polly 2 *, Hans Pancherz 3 *, Ariane Hohoff 4 *
Objectives. Objectives. Objectives. Objectives. Describe Class II div 1
Class II div 1 Malocclusion Class II div 1 Malocclusion Objectives OR What can we do about Goofy? Objectives Describe Class II div 1 Objectives Describe Class II div 1 Describe principles of treatment
CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.
CHAPTER 10 RESTS AND DEFINITIONS A REST is any rigid part of an RPD framework which contacts a properly prepared surface of a tooth. A REST PREPARATION or REST SEAT is any portion of a tooth or restoration
Dental arch morphology of Mazahua and mestizo teenagers from central Mexico
Original Article Braz J Oral Sci. April/June 2009 - Volume 8, Number 2 Dental arch morphology of Mazahua and mestizo teenagers from central Mexico Edith Lara-Carrillo 1, Juan Carlos González-Pérez 2, Toshio
Classification of Malocclusion
Classification of Malocclusion What s going on here? How would you describe this? Dr. Robert Gallois REFERENCE: Where Do We Begin? ESSENTIALS FOR ORTHODONTIC PRACTICE By Riolo and Avery Chapter 6 pages
Condylar position in children with functional posterior crossbites: before and after crossbite correction*
PEDIATRIC DENTISTRY/Copyright 1980 by The American Academy of Pedodontics/Vol. 2, No. 3 Condylar position in children with functional posterior crossbites: before and after crossbite correction* David
Use of orthodontic records in human identification*
O r i g i n a l A r t i c l e Use of orthodontic records in human identification* Rhonan Ferreira da Silva**, Patrícia Chaves***, Luiz Renato Paranhos****, Marcos Augusto Lenza*****, Eduardo Daruge Júnior******
Lasers and Specturbility of Light Scattering Liquids - A Review
Artigo Original Revista Brasileira de Física Médica.2011;5(1):57-62. Reproducibility of radiant energy measurements inside light scattering liquids Reprodutibilidade de medidas de energia radiante dentro
Full Crown Module: Learner Level 1
Full Crown Module Restoration / Tooth # Full Gold Crown (FGC) / 30 Extensions: Porcelain Fused to Metal (PFM) / 12 All Ceramic / 8 Learner Level 1 Mastery of Tooth Preparation Estimated Set Up Time: 30
Modern Tooth Replacement Strategies & Digital Workflow
Modern Tooth Replacement Strategies & Digital Workflow Case Studies by Dr Maurice Salama, DMD AS PUBLISHED BY Dentistry Today, June 2014 Complete Implant Restoration System FACTS: Implant Dentistry Has
Introduction to Dental Anatomy
Introduction to Dental Anatomy Vickie P. Overman, RDH, MEd Continuing Education Units: N/A This continuing education course is intended for dental students and dental hygiene students. Maintaining the
Removable appliances II. Functional jaw orthopedics
Removable appliances II. Functional jaw orthopedics Melinda Madléna DMD, PhD Associate professor Department of Pedodontics and Orthodontics Faculty of Dentistry Semmelweis University Budapest Classification
Headgear Appliances. Dentofacial Orthopedics and Orthodontics. A Common Misconception. What is Headgear? Ideal Orthodontic Treatment Sequence
Ideal Orthodontic Treatment Sequence Headgear Appliances Natalie A. Capan, D.M.D. 580 Sylvan Avenue, Suite 1M Englewood Cliffs, New Jersey 07632 (201)569-9055 www.capanorthodontics.com [email protected]
A Guideline for the Extraction of First Permanent Molars in Children.
A Guideline for the Extraction of First Permanent Molars in Children. Introduction The relative timing of coronal development associated with first permanent molars makes them susceptible to chronological
PROPORTIONS. The new Golden Rules in dentistry. History. Abstract
M PROPORTIONS The new Golden Rules in dentistry Dr. Alain Méthot Abstract Since the beginning Cosmetic Dentistry has been using the principles of Golden Proportion (1: 0.618) as a guideline for smile design...
Ando A., Nakamura Y., Kanbara R., Kumano H., Miyata T., Masuda T., Ohno Y. and Tanaka Y.
11. The Effect of Abutment Tooth Connection with Extracoronal Attachment using the Three Dimensional Finite Element Method - Part 2. The Construction of Finite Element Model from CT Data - Ando A., Nakamura
Sucking behaviors have long been recognized to
ORIGINAL ARTICLE Duration of nutritive and nonnutritive sucking behaviors and their effects on the dental arches in the primary dentition John J. Warren, DDS, MS, a and Samir E. Bishara, BDS, D Ortho,
Congenital absence of mandibular second premolars
CLINICIAN S CORNER Congenitally missing mandibular second premolars: Clinical options Vincent G. Kokich a and Vincent O. Kokich b Seattle, Wash Introduction: Congenital absence of mandibular second premolars
Molar Uprighting Dr. Margherita Santoro Division of Orthodontics School of Dental and Oral surgery. Consequences of tooth loss.
Molar Uprighting Dr. Margherita Santoro Division of Orthodontics School of Dental and Oral surgery Molars The wide occlusal surface is designed for food grinding. The surface needs to be aligned with the
Ideal treatment of the impaired
RESEARCH IMPLANTS AS ANCHORAGE IN ORTHODONTICS: ACLINICAL CASE REPORT Dale B. Herrero, DDS KEY WORDS External anchorage Pneumatized Often, in dental reconstruction, orthodontics is required for either
Three-Dimensional Analysis Using Finite Element Method of Anterior Teeth Inclination and Center of Resistance Location
Three-Dimensional Analysis Using Finite Element Method of Anterior Teeth Inclination and Center of Resistance Location Allahyar GERAMY 1, Ahmad SODAGAR 1, Mehdi HASSANPOUR 1 Objective: To locate the centre
Retrospective analysis of factors influencing the eruption of delayed permanent incisors after supernumerary tooth removal
Retrospective analysis of factors influencing the eruption of delayed permanent incisors after supernumerary tooth removal R.A.E. BRYAN*, B.O.I. COLE**, R.R. WELBURY* ABSTRACT. Aim This was to assess the
Bitewing Radiography B.E. DIXON. B.D.S., M.Sc., D.P.D.S.
Bitewing Radiography B.E. DIXON B.D.S., M.Sc., D.P.D.S. Main Indications Detection of Dental Caries Monitoring progression of caries Assessment of existing restorations Assessment of Periodontal status
Rapid Maxillary Expansion Followed by Fixed Appliances: A Long-term Evaluation of Changes in Arch Dimensions
Original Article Rapid Maxillary Expaion Followed by Fixed Appliances: A Long-term Evaluation of Changes in Arch Dimeio James A. McNamara Jr, DDS, PhD a ; Tiziano Baccetti, DDS, PhD b ; Lorenzo Franchi,
IMPLANT DENTISTRY EXAM BANK
IMPLANT DENTISTRY EXAM BANK 1. Define osseointegration. (4 points, 1/4 2. What are the critical components of an acceptable clinical trial? (10 points) 3. Compare the masticatory performance of individuals
U.O.C. Ortognatodonzia Area Funzionale Omogena di Odontoiatria
U.O.C. Ortognatodonzia Area Funzionale Omogena di Odontoiatria Alcune pubblicazioni della Scuola: Impacted maxillary incisors: diagnosis and predictive measurements. Pavoni C, Mucedero M, Laganà G, Paoloni
THE EFFECT OF INCISOR AND CANINE ANGULATION ON MAXILLARY ARCH PERIMETER
THE EFFECT OF INCISOR AND CANINE ANGULATION ON MAXILLARY ARCH PERIMETER 1. Introduction: Orthodontics has, in recent decades gone through some major modifications such as the development of space age metal
Orthodontic mini-implants, or temporary anchorage devices
Anchors, away by John Marshall Grady, DMD, Dan E. Kastner, DMD, and Matthew C. Gornick, DMD Drs. John Marshall Grady (center), Dan E. Kastner (left), and Matthew C. Gornick (right). Drs. John Marshall
Treatment planning for the class 0, 1A, 1B dental arches
Treatment planning for the class 0, 1A, 1B dental arches Dr.. Peter Hermann Dr Reminder: Torquing movement on tooth supported denture : no movement Class 1 movement in one direction (depression) Class
CLASSIFICATION OF CARIOUS LESIONS AND TOOTH PREPARATION.
CLASSIFICATION OF CARIOUS LESIONS AND TOOTH PREPARATION. ١ G.V. BLACK who is known as the father of operative dentistry,he classified carious lesions into groups according to their locations in permanent
ABO OBJECTIVE GRADING SYSTEM BASED ON CLINICAL PHOTOGRAPHY
ABO OBJECTIVE GRADING SYSTEM BASED ON CLINICAL PHOTOGRAPHY Bryan R. Wirtz, D.D.S. An Abstract Presented to the Graduate Faculty of Saint Louis University in Partial Fulfillment of the Requirements for
porcelain fused to metal crown
Lectur.5 Dr.Adel F.Ibraheem porcelain fused to metal crown the most widely used fixed restoration,it is full metal crown having facial surface (or all surfaces) covered by ceramic material. It consist
Knowing the rate of tooth movement gives the
SPECIAL ARTICLE Changes over time in canine retraction: An implant study Renato Parsekian Martins, a Peter H. Buschang, b Luiz Gonzaga Gandini, Jr, c and P. Emile Rossouw d Araraquara, São Paulo, Brazil,
Full Crown Module: Learner Level 3
Full Crown Module Restoration / Tooth # Full Gold Crown (FGC) / mesially tilted 30 Extensions: Porcelain Fused to Metal (PFM) / lingually 21 All Ceramic / rotated 12 Learner Level 3 Preparation of Malpositioned
Dental Implant Treatment after Improvement of Oral Environment by Orthodontic Therapy
Dental implant treatment after impr Title environment by orthodontic therapy. Sekine, H; Miyazaki, H; Takanashi, Author(s) Matsuzaki, F; Taguchi, T; Katada, H Journal Bulletin of Tokyo Dental College,
Projecting a new smile from a facial photograph:
I special _ digital smile design Projecting a new smile from a facial photograph: A new way to plan multidisciplinarydental treatments Authors_ Drs Marco Del Corso, Italy, & Alain Méthot, Canada without
A. DEVELOPMENT OF THE DENTAL ORGAN (ENAMEL ORGAN):
A. DEVELOPMENT OF THE DENTAL ORGAN (ENAMEL ORGAN): AS EARLY AS THE SECOND MONTH OF FETAL LIFE, THE DEVELOPMENT OF THE DECIDUOUS TEETH MAY FIRST BECOME EVIDENT. 1. Dental lamina and Bud stage At about six
Optimet 3D Dental Multi-Facet Scanner Attainable Accuracy for Dental Application Cases
Optimet 3D Dental Multi-Facet Scanner Attainable Accuracy for Dental Application Cases Optimet Dental 3D Scanner This paper presents an overview of the Optimet multi-facet Dental Scanner used for 3D scanning
In Class IV arch: Fulcrum line passes through two abutments adjacent to single edentulous space.
It is that part of removable partial denture which assists the direct retainers in preventing displacement of distal extension denture bases by resisting lever action from the opposite side of the fulcrum
Periapical radiography
8 Periapical radiography Periapical radiography describes intraoral techniques designed to show individual teeth and the tissues around the apices. Each film usually shows two to four teeth and provides
Case Report Case studies on local orthodontic traction by minis-implants before implant rehabilitation
Int J Clin Exp Med 2015;8(5):8178-8184 www.ijcem.com /ISSN:1940-5901/IJCEM0006299 Case Report Case studies on local orthodontic traction by minis-implants before implant rehabilitation Pei Shen *, Wei-Feng
NEW YORK CITY COLLEGE OF TECHNOLOGY
NEW YORK CITY COLLEGE OF TECHNOLOGY THE CITY UNIVERSITY OF NEW YORK DEPARTMENT OF RESTORATIVE DENTISTRY DEPARTMENT: COURSE CODE: COURSE TITLE: COURSE DESCRIPTION: CLASS HOURS & CREDITS: NUMBER OF WEEKS:
POLICY HOLDER/SUBSCRIBER INFORMATION
Dental Claim Form Instructions Claim Field Identification 1. Type of Transaction Statement of Actual Services EPSDT/Title XIX Request for Predetermination 2. Predetermination/ Prior Authorization Code
ADA Dental Claim Form (2012 American Dental Association) Completion Instructions Page 1 of 17
Page 1 of 17 Introduction The ADA Dental Claim Form has been revised to incorporate key changes to the HIPAA standard electronic dental claim transaction. This version of the form, front and reverse sides,
Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment
Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment by Dr. Ronald Jung and Master Dental Technician Xavier Zahno Initial situation
Table of Contents Section 6 Table of Contents
Table of Contents Section Table of Contents Victory Series First Molar Bands...2 Victory Series Second Molar Bands... Unitek General Purpose Molar Bands...10 Unitek Pedodontic Molar Bands...11 Unitek Proportioned
Treatment of dental and skeletal bimaxillary protrusion in patient with Angle Class I malocclusion
Treatment of dental and skeletal bimaxillary protrusion in patient with Angle Class I malocclusion Claudio José Ramos 1 In the orthodontic clinic, skeletal and dental bimaxillary protrusion is presented
Double-blind study for evaluation of complete dentures made by two techniques with and without face-bow.
Braz J Oral Sci. April/June 2004 - Vol. 3 - Number 9 Daniela Fernandes Figueira Nascimento 1 Renata Beatriz Luz Patto 1 Leonardo Marchini 1,2 Vicente de Paula Prisco da Cunha 1,3 1 School of Dentistry,
Guidelines for Referrals for Orthodontic Treatment
Advice for General Dental Practitioners, PCTs and LHBs Guidelines for Referrals for Orthodontic Treatment This document has been produced by the British Orthodontic Society Guidelines for Referrals for
Tough Choice for Young First Permanent molars: To Do Pulp Treatment or to Extract?
Tough Choice for Young First Permanent molars: To Do Pulp Treatment or to Extract? Jung-Wei Chen, DDS, MS, PhD Professor and Program Director Advanced Education Program in Pediatric Dentistry Loma Linda
ABSTRACT INTRODUCTION. Facial Esthetics. Dental Esthetics
ABSTRACT The FACE philosophy is characterized by clearly defined treatment goals. This increases diagnostic ability and improves the quality and stability of the end result. The objective is to establish
Scientific Article. Laboratory-made Space Maintainers: A 7-year Retrospective Study from Private Pediatric Dental Practice
Scientific Article Laboratory-made Space Maintainers: A 7-year Retrospective Study from Private Pediatric Dental Practice Mehrdad Fathian, DDS 1 David B. Kennedy, BDS, LDS, MSD 2 M. Reza Nouri, DMD, Dip
Non-carious dental conditions
Non-carious dental conditions Children s Dental Health in the United Kingdom, 2003 Barbara Chadwick, Liz Pendry October 2004 Crown copyright 2004 Office for National Statistics 1 Drummond Gate London SW1V
The ideal bracket system would allow orthodontists
2013 JCO, Inc. May not be distributed without permission. www.jco-online.com Clinical Effectiveness and Efficiency of Customized vs. Conventional Preadjusted Bracket Systems DENNIS J. WEBER II, DMD, MS
Pitch, roll, and yaw: Describing the spatial orientation of dentofacial traits
SPECIAL ARTICLE Pitch, roll, and yaw: Describing the spatial orientation of dentofacial traits James L. Ackerman, a William R. Proffit, b David M. Sarver, a Marc B. Ackerman, c and Martin R. Kean d Chapel
your talent. our technology. the perfect fit.
your talent. our technology. the perfect fit. itero - exclusively distributed in Europe by The digital revolution Changing the Face of Dentistry Digital technology ensures a more accurate impression from
The Third-Order Angle and the Maxillary Incisor s Inclination to the NA Line
Original Article The Third-Order Angle and the Maxillary Incisor s Inclination to the NA Line Michael Knösel a ; Dietmar Kubein-Meesenburg b ; Reza Sadat-Khonsari c ABSTRACT Objective: To evaluate the
ORTHODONTIC SCREENING GUIDE FOR NORTH DAKOTA HEALTH TRACKS NURSES
ORTHODONTIC SCREENING GUIDE FOR NORTH DAKOTA HEALTH TRACKS NURSES The North Dakota Department of Human Services Medical Services Division and the North Dakota Department of Health s Oral Health Program
HEALTH SERVICES POLICY & PROCEDURE MANUAL. SUBJECT: Types of Dental Treatments Provided EFFECTIVE DATE: July 2014 SUPERCEDES DATE: January 2014
PAGE 1 of 5 References Related ACA Standards 4 th Edition Standards for Adult Correctional Institutions 4-4369, 4-4375 PURPOSE To provide guidelines for determining appropriate levels of care and types
Activity: Can You Identify the Age?
Activity: Can You Identify the Age? Skeletons are good age markers because teeth and bones mature at fairly predictable rates. How Teeth Reveal Age For toddler to age 21, teeth are the most accurate age
Dr. Park's Publications
Dr. Park's Publications Jae Hyun Park, D.M.D., M.S.D., M.S., Ph.D. Diplomate, American Board of Orthodontics Editor-in-Chief, Pacific Coast Society of Orthodontists Chief Editor, Computed Tomography: New
Basic Training 101 TRAINING FOR THE CLINICAL TEAM WITH CONCENTRATION ON COMMUNICATION SKILLS AND CLINICAL SYSTEMS. By: Charlene White, President
Basic Training 101 TRAINING FOR THE CLINICAL TEAM WITH CONCENTRATION ON COMMUNICATION SKILLS AND CLINICAL SYSTEMS By: Charlene White, President Progressive Concepts, Inc. Consultations, Seminars, Speaking
Ridge Reconstruction for Implant Placement
Volume 1, No. 5 July/August 2009 The Journal of Implant & Advanced Clinical Dentistry Ridge Reconstruction for Implant Placement 2 Hours of CE Credit Oral Implications of Cancer Chemotherapy Immediate
Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental
Implant Solutions for the Implant Patient: Diagnosis and Treatment Planning for Predictable Results David Little, DDS 6961 U.S. Highway 87 East San Antonio, TX 78263 Phone: (210)648-4411 Fax: (210) 648-6498
Clinical Practice Guideline For Orthodontics
Clinical Practice Guideline For Orthodontics MOH- Oral Health CSN -Orthodontics -2010 Page 1 of 15 Orthodontic Management Guidelines 1. Definitions: Orthodontics is the branch of dentistry concerned with
Healing Abutment Selection. Perio Implant Part I. Implant Surface Characteristics. Single Tooth Restorations. Credit and Thanks for Lecture Material
Healing Abutment Selection Perio Implant Part I Credit and Thanks for Lecture Material Implant Surface Characteristics!CAPT Robert Taft!CAPT Greg Waskewicz!Periodontal Residents NPDS and UMN!Machined Titanium!Tiunite!Osseotite
Mandibular Permanent Second Molar Impaction Treatment options and outcome
Open Journal of Dentistry and Oral Medicine 1(1): 9-14, 2013 DOI: 10.13189/ojdom.2013.010103 http://www.hrpub.org Mandibular Permanent Second Molar Impaction Treatment options and outcome Nir Shpack 1,
Orthodontic treatment of gummy smile by using mini-implants (Part I): Treatment of vertical growth of upper anterior dentoalveolar complex
O n l i n e O n l y Orthodontic treatment of gummy smile by using mini-implants (Part I): Treatment of vertical growth of upper anterior dentoalveolar complex Tae-Woo Kim*, Benedito Viana Freitas** Abstract
Anatomic Anomalies. Anomalies. Anomalies. Anomalies. Supernumerary Teeth. Supernumerary Teeth. Steven R. Singer, DDS 212.305.5674 srs2@columbia.
Anatomic Anomalies Steven R. Singer, DDS 212.305.5674 [email protected] Anomalies! Anomalies are variations in the:! Size! Morphology! Number! Eruption of the teeth Anomalies Anomalies There are two categories:!
Many esthetic concepts about the face and the
ORIGINAL ARTICLE Impact of dental asymmetries on the perception of smile esthetics Sérgio Pinho, a Carolina Ciriaco, b Jorge Faber, a and Marcos A. Lenza c Brasília, DF, and Goiás, Brazil Introduction:
Humana Health Plans of Florida. Important:
Humana Health Plans of Florida Important: Dental discount membership in Florida is determined by viewing the member s ID card and verifying that the Humana Logo and Medicare name is listed with an effective
Managing the Developing Occlusion. A guide for dental practitioners
Managing the Developing Occlusion A guide for dental practitioners INTRODUCTION Whether knowingly or not, every dentist who treats children practices orthodontics. It is not enough to think of orthodontics
Managing a Case of Sensitive Abutment Situations through Use of a Fixed Movable Prosthesis A Clinical Report
www.jmscr.igmpublication.org Managing a Case of Sensitive Abutment Situations through Use of a Fixed Movable Prosthesis A Clinical Report Authors Khurshid A. Mattoo 1, Shailesh Jain 2 1 Assistant Professor,
Tooth preparation J. C. Davenport, 1 R. M. Basker, 2 J. R. Heath, 3 J. P. Ralph, 4 P-O. Glantz, 5 and P. Hammond, 6
12 5 Tooth preparation J. C. Davenport, 1 R. M. Basker, 2 J. R. Heath, 3 J. P. Ralph, 4 P-O. Glantz, 5 and P. Hammond, 6 This final article in the series describes the modification of teeth to improve
Using The Canary System to Develop a Caries Management Program for Children. we design therapies to treat or remineralize early carious lesions?
Using The Canary System to Develop a Caries Management Program for Children Dr. Stephen H. Abrams Dental caries is the most common oral disease we treat in paediatric dentistry. We place restorations to
Anchorage onto deciduous teeth: effectiveness of early rapid maxillary expansion in increasing dental arch dimension and improving anterior crowding
Mutinelli et al. Progress in Orthodontics (2015) 16:22 DOI 10.1186/s40510-015-0093-x RESEARCH Open Access Anchorage onto deciduous teeth: effectiveness of early rapid maxillary expansion in increasing
Page 1 of 10 BDS FINAL PROFESSIONAL EXAMINATION 2007 Prosthodontics (MCQs) Model Paper SECTION I
Page 1 of 10 COMPLETE DENTURES ANATOMICAL LANDMARKS SECTION I 1. There are many landmarks in the oral cavity which helps in designing complete dentures. One of the important landmarks is fovea palatini.
Orthodontic Treatment of an Ankylosed Maxillary Central Incisor through Osteogenic Distraction
Case Report Orthodontic Treatment of an Ankylosed Maxillary Central Incisor through Osteogenic Distraction Doğan Dolanmaz a ; Ali Ihya Karaman b ; A.Alper Pampu c ; Ahu Topkara d ABSTRACT Tooth ankylosis
ABSTRACT. VM Phillips 1, TJ van Wyk Kotze 2
20 TESTING STANDARD METHODS OF DENTAL AGE ESTIMATION BY MOORREES, FANNING AND HUNT AND DEMIRJIAN, GOLDSTEIN AND TANNER ON THREE SOUTH AFRICAN CHILDREN SAMPLES VM Phillips 1, TJ van Wyk Kotze 2 1 Department
Esthetic analysis of the smile
Braz J Oral Sci. April-June 2007 - Vol. 6 - Number 21 Giulliana Panfiglio Soares 1* Thiago Assunção Valentino 2* Débora Alves Nunes Leite Lima 2* Luis Alexandre Maffei Sartini Paulillo 3* Frederico Augusto
