Development of a Process Assessment Model for Medical Device Software Development
|
|
|
- Ambrose Carroll
- 9 years ago
- Views:
Transcription
1 Development of a Process Assessment Model for Medical Device Software Development Marion Lepmets, Paul Clarke, Fergal McCaffery, Anita Finnegan, Alec Dorling Regulated Software Research Centre, Dundalk Institute of Technology, Dundalk, Ireland {marion.lepmets, paul.clarke, fergal.mccaffery, anita.finnegan, alec.dorling Abstract Software that is incorporated into a medical device, or which is a standalone medical device in its own right, is of a safety critical nature and subject to regulation from various jurisdictions (principally the EU and the US). In order to satisfy jurisdictional regulations, developers of medical device software generally implement standards and guidance provided by international standards bodies and national administrative departments. However, the various standards and guidance documents are not developed as a single cohesive set but often as separate resources addressing distinct areas of concern. The result for medical device software developers is that integration of these various sources represents a challenging undertaking. The aim of this paper is to describe the integration of the several process models and regulatory standards, first, into a process reference model and then into a process assessment model for medical device software development. The focus is on the integration of regulatory standards from the medical device domain with generic software development process models, resulting in a unified best practice framework for medical device software development. The process reference model for medical device software development is going to be published this year as IEC TR , and the process assessment model for medical device software development is currently being validated through pilot studies in medical device industry. This best practice framework will help small software developers in their adoption of regulations-compliant best practices while reducing the overhead associated with understanding the long list of regulations and standards they need to adhere to when developing software for medical devices. This framework will also help the manufacturers in selecting their software suppliers assuring that the suppliers have adopted the best practices and are compliant with the medical device standards and regulations. Keywords Process Assessment Model, Process Reference Model, Medical Device Software, Medical Device regulations, Best Practice Framework EuroSPI
2 1 Introduction A basic requirement of the design of a medical device software process is that it satisfies the regulatory demands associated with the medical devices under construction; as failure to satisfy regulation in a particular region will mean that the device cannot be placed upon the market. In a sense, this is similar to the basic requirement of a software development process: that the process should fit the needs of the project [1]. However, in practice the realisation of this basic requirement has proven to be difficult to achieve in the general software engineering domain. Consequently, many software development approaches have been proposed and implemented, resulting in much discussion regarding the benefits and limitations of the various approaches [2]. It therefore seems likely that no single software approach should be universally prescribed for the general practice of software development. This is essentially owing to the complex interplay between people and the economic activity of commercial software development. 1.1 Medical device regulations and standards A medical device can consist entirely of software or have software as a component of the overall medical device system. In order to be able to market a medical device within a particular region it is necessary to comply with the regulatory demands of that region. Two of the largest global bodies responsible for issuing and managing medical device regulation belong to the central governing functions of the US and EU. In the case of the US, the Food and Drug Administration (FDA) issues the pertinent regulation through a series official channels, including the Code of Federal Regulation (CFR) Title 21, Chapter I, Subchapter H, Part 820 [3]. Under US regulation, there are three medical device safety classifications: Class I, Class II and Class III. The medical device safety classification is based on the clinical safety of the device. Class I devices are not intended to support or sustain human life, and may not present an unreasonable risk of harm. Class II devices could cause damage or harm to humans. An example of a Class II medical device is a powered wheelchair. Class III medical devices are usually those that support or sustain human life, and are of significant importance in the prevention of human health impairment. An example of a Class III device is an implantable pacemaker. All implantable devices are Class III medical devices as the surgery required carries with itself additional high risks from anaesthesia and possible infections that go beyond the technical and engineering safety risks of the correct performance of the device. In the EU, the corresponding regulation is outlined in the general Medical Device Directive (MDD) 93/42/EEC [4], the Active Implantable Medical Device Directive (AIMDD) 90/385/EEC [5], and the Invitro Diagnostic (IVD) Medical Device Directive 98/79/EC [6] - all three of which have been amended by 2007/47/EC [7]. Although slightly different to the US safety classifications that are based on clinical safety of the device, the EU classifications essentially embody similar classifications and limitations, where Class I corresponds to Class I, Class IIa and IIb to Class II, and Class III to Class III. A further safety classification applies to the software in the medical device as outlined in IEC 62304, wherein the safety classification is concerned with the worst possible consequence in the case of a software failure (as compared with general medical device safety classification which is based on the difficulty of a regulator to determine if the device will be safe). Hence, some Class II medical devices can cause serious injury or even death, but they are Class II because they are similar (in clinical use and safety) to well understood devices that have been used before. Since IEC safety classifications are based on worse case failure of the software, it is possible that Class II medical devices can have Class III software. In the medical device domain, ISO 13485:2003 (ISO from hereon) [8] outlines the requirements for regulatory purposes from a QMS perspective. ISO 13485, which is based on ISO 9001 [9], can be used to assess an organisation s ability to meet both customer and regulatory requirements. However, ISO does not offer specific guidance on medical device software development. IEC 62304:2006 (IEC from hereon) [10], which can be used in conjunction with ISO 13485, does offer a framework for the lifecycle processes necessary for the safe design and maintenance of medical device software. As a basic foundation, IEC assumes that medical device software is developed and maintained within a QMS such as ISO 13485, but does not require an organisation to 1.2 EuroSPI 2014
3 be certified in ISO Therefore, IEC can be considered to be a software development specific supplement to ISO IEC is based on ISO/IEC 12207:1995 [11] which although a comprehensive standard for software development lifecycle processes has effectively been decommissioned following the publication of the more extensive ISO/IEC 12207:2008 [12]. Furthermore, other developments in the ISO and IEC communities for software development, such as ISO/IEC [13], have provided significant additional levels of software process detail to support ISO/IEC 12207:2008. IEC is currently being revised to better align with ISO/IEC 12207:2008. IEC is a critical standard for medical device software developers as it is the only standard that provides recommendations for medical device software implementations based on the worst consequences in the case the software failure causing hazards. Furthermore, for general medical device risk management, IEC is used in conjunction with ISO [14], with IEC [15] providing guidance on the application of ISO for software development. Additionally, as IEC considers a medical device system to consist of software as part of an overall medical device system, the system level requirements are not included within IEC but instead within the medical device product standard IEC [16]. Also it should be noted that due to the increasing importance of usability within the medical device industry organisations should also adhere to the medical device usability requirements outlined in IEC [17]. Numerous different medical device standards and regulations now exist, some of which are interlinked with generic software development standards and others which are inconsistent. The dominant medical device software standards such as IEC are not yet aligned with the approach adopted in the general software development standards community since the 1995 publication of ISO/IEC One significant change in this respect has been the introduction of a harmonised approach to process description (as defined in ISO/IEC [18]) which involves the identification of core process outcomes that can later be harnessed to develop a process assessment method. A further significant change relates to the movement in the general software development standards community (and in other safety-related domains) to include a software process improvement dimension that can be instrumental in guiding software development organisations towards the required process targets. In effect, the medical device standards have not kept up with the changes that have been made to the general software development standards. There are several reasons why the medical device standards lag the updates to the general software development standards, (perhaps) most importantly the IEC stability period during which adopted harmonised standards are not to be changed unless the proposed changes are necessary in terms of safety. With the expanding role of software in medical devices, there is a case to be made for introducing the accumulated up-to-date wisdom in the general software development standards into the medical device software development specific standards in a uniform fashion and work in this direction should not wait for the IEC stability period to come to an end, but rather proceed in the interim period (such as the work reported upon in this paper). In order to identify an appropriate architecture for introducing the significant body of general software process knowledge into the medical device process domain, an initial important step involves the building of a process reference model (PRM) for medical device software development. The approach used for the PRM development is described in the next section. We then illustrate the architecture and the challenging task of integrating various regulatory standards and informative guidance into a process assessment model (PAM) to allow consistent evaluation of medical device software development processes against the set of standards these organisations have to adhere to. Finally, we summarize the paper along with some concluding remarks. 2 Development of the PRM A process reference model (PRM) describes a set of processes in a structured manner through a process name, process purpose and process outcomes. Process outcomes are the normative requirements the process should satisfy to achieve the purpose of the process. The PRM for medical device software development is based on various international medical device and generic software development standards as shown on Figure 1. The development of the PRM was carried out in two steps. In the first step, the PRM for medical device software life cycle processes described in IEC was developed, entitled IEC which is currently under national ballot at IEC. This PRM was a result of an integration of requirements from ISO/IEC and IEC following the guidelines for process descriptions set forth in ISO/IEC EuroSPI
4 Medical Device software development PRM Guidelines for Process Description: ISO/IEC Software lifecycle processes: ISO/IEC 12207:2008 Medical device software lifecycle processes: IEC Quality Management System Standard: ISO Figure 1. Building blocks of medical device software development PRM Risk management in medical devices: ISO The mapping of the requirements from the two different international standards aims at integrating the varying underlying requirements into a more abstract set of PRM-based requirements which can be applied in the development of a medical device software development PAM. In this section, we outline the approach to mapping those processes that have distinguishable one-to-one mappings from IEC to ISO/IEC With the exception of the IEC risk management process, the majority of the IEC processes are well mapped to the ISO/IEC software life cycle processes. The essential difference for many of these processes is that the safety critical activities are embedded throughout the IEC software life cycle processes. In conducting process mappings for the directly corresponding processes, we applied the systematic approach of constant comparison and memoing as described by Grounded Theory. Constant comparison is an iterative process of data integration where the dimensions and the properties specific to data are specified [19]. This iterative process is supported by keeping memos that are a written record of analyses. Memoing forces the analyst to think about the data and it is in thinking that analysis actually occurs [20]. In this requirements integration activity, we conducted several iterations of constant comparison and memoing. In order to increase the validity of the mapping, a formal independent mapping of the individual processes was performed by two experienced software process researchers. The first iteration took place when one of the researchers conducted an initial comparison of the two processes (ISO/IEC and IEC 62304). The result of this first iteration was a proposed mapping along with detailed memos that capture the reasoning behind the proposed process mappings. The second researcher then conducted a review of the first comparison and took notes for the underlying reasons for agreeing or disagreeing with the first researcher. The researchers then reviewed all the data together in the third iteration of constant comparison and they memoed the review results while finalising the requirements integration. Additional ideas and propositions of data integration that occured while the researchers finalised the comparison were again memoed and reviewed by both researchers. Iterative cycles of constant comparison were undertaken until the researchers had no conflict (or no new suggestions to the agreed requirements integration). Constant comparison is a systematic approach to analysing and integrating the process requirements that are written using different terminology and concepts [19]. Memos permit the tracking of justifications for process integration. The memos are also crucial in the validation of the PRM as the reviewers will be able to follow the data analysis and integration process in great detail. At the time of submitting this paper, the PRM developed in the first step has been approved for publication by the IEC national bodies as IEC DTR : Process Reference Model for Medical Device Software Life Cycle Processes (IEC 62304). IEC TR will be published in the middle of this year. In the second step of the PRM development, IEC was extended with medical device regulatory standards that medical device software development organisations have to adhere to. The requirements from the international standards ISO and ISO where then analysed and the requirements that were not yet in the PRM were then integrated into it. ISO is a Quality Management System standard setting the requirements for regulatory purposes. ISO describes the application of Risk Management to medical devices. Both of these standards are mandatory for medical device software organisations. To have a comprehensive medical device software PRM, the relevant requirements from these two mandatory standards were included. The approach of integrating requirements from different standards was carried out similarly to the one described above with iterations of reviews by experts until there were no more contradictions in the experts proposals for integration. 1.4 EuroSPI 2014
5 The resulting medical device software development PRM describes processes that could be grouped into three the system life cycle processes, the software life cycle processes and the supporting processes. ISO requirements are primarily related to the system level processes which were derived from ISO/IEC in the first PRM development step. ISO maps mostly to the Software Risk Management process described also in IEC ISO sets the requirements for Quality Management System (QMS) for Medical Devices. These requirements were integrated into the Medical Device Software Development PAM through relevant new Process Outcomes where no corresponding ones already exist, or as additional details in Base Practices where corresponding Process Outcomes already existed. Some of the QMS requirements target higher Capability Levels, in which case the requirements were related to Generic Practices PA 2.1 (e.g. on allocating resources) or to PA 2.2 (e.g. on documentation) on Capability Level 2. The outcomes or base practices derived from ISO were highlighted to visualize the source standard. This would then allow detailed feedback to companies in their compliance to the specific standards as a result of process assessment. ISO distributes the risk management related requirements across all software life cycle processes. To avoid major duplication, the risk management requirements were kept only in the Software Risk Management process of the main body of the PAM. Instead of distributing these requirements across life cycle processes, a table was added in the Annex of the PAM that lists the specific risk management requirements for each software life cycle process. These requirements need to be added to the selected software life cycle processes for process assessment in the case where the process assessment will not include the Software Risk Management process. The table in the Annex provides the Outcomes from ISO and their corresponding Base Practice texts from IEC as well as the suggested location in the list of already existing Outcomes in each of the software life cycle processes. As a result of the integration activities described above, the medical device software PRM consists of 25 processes in the three sets of software life cycle processes, software support processes, and system life cycle processes. In the following section we describe how this PRM was extended with additional elements for medical device software development process assessment model (PAM). This PAM will allow the evaluation of software and systems development processes against all the medical device standards mentioned above. 3 Development of the PAM The aim of the Medical Device Software Development PAM is to provide a comprehensive model for assessing the software and systems development processes against the widely required medical device regulations, standards and guidelines that a software development organisation in the medical device section has to adhere to. Medical Device Software Development PAM has two dimensions - process dimension and capability dimension. Process dimension lists three groups of processes from various models and standards specified below, i.e. systems life cycle processes, software life cycle processes, and support processes. Each process is described in terms of a Process Name, Process Purpose, Process Outcomes, Base Practices, Work Products and Work Product Characteristics. Process Outcomes are the normative requirements within a process, the achievement of which will allow satisfying the Process Purpose statement. Base Practices are informative activities that illustrate one possible way (workflow) to achieve the corresponding Process Outcomes. Work Products are artefacts that are either produced or used by the Base Practices, both support the achievement of the Process Outcome. Each Work Product is further described in terms of its content called Work Product Characteristics. In the case of the medical device software development PAM, some of these Work Products are normative as they are based on the requirements derived from IEC 62304, ISO or ISO Similarly, their content may have been specified in these standards, and if that is the case, this information has been carried forward to Work Products Characteristics of the PAM. Medical Device Software Development PAM includes information from the following standards and models. First, the baseline PAM is built upon the integrated model of IEC (Medical device software life cycle processes) and ISO/IEC (Software and Systems life cycle processes) the PRM for IEC 62304, i.e. IEC and the QMS and Risk Management requirements added in the second step of the PRM development from ISO and ISO 14971, respectively. The Process Outcomes were derived from these four standards resulting in the PRM for Medical Device Software Development as described in the previous section. This PRM was extended with corresponding Base EuroSPI
6 Practices, the process implementation steps that result in the achievement of the outcomes, from IEC 62304, ISO/IEC and IEC (for ISO 14971). As mentioned previously, IEC provides guidance on the application of ISO (Risk Management) to Medical Device Software. This guidance information was added to the Base practices to correspond to the requirements from ISO described in the normative part of the model illustrating a way for achieving these requirements. Most of the information from IEC was integrated into the PAM through Software Risk Management process Base Practices. Additional base practice information was then derived from the FDA guidance documents on Premarket Submission [21], Software Validation [22], and Off-The-Shelf (OTS) [23] software. In most cases, this guidance was integrated into the existing processes through adding onto the existing Base Practices and Work Products or adding new Base Practices. Software Validation is not described in a separate process in IEC but as the FDA guidance provides the current best practices for software development in medical device domain, this area should also be considered. Additional processes of Software Validation, Software Installation and Software Acceptance Support were therefore added from ISO/IEC to satisfy the requirements of the FDA Guidance Document on Software Validation. Best practices from the FDA guidance documents were then analysed and iteratively integrated into these three processes. Figure 2 below describes the different sources for the medical device software development PRM and PAM. The medical device software development PRM is based on IEC 62304, ISO/IEC 12207, ISO and ISO The PAM then extends this PRM with base practices and work products, some of the latter also being normative as they are described in IEC 62304, ISO or ISO as requirements. Where process outcomes are derived from ISO/IEC 12207, their corresponding base practices and work products are derived from ISO/IEC Where process outcomes are derived from ISO 14971, their corresponding base practices are derived from IEC In addition to these sources, FDA guidance on premarket submissions, software validation and off-the-shelf software have been added to the informative base practices where appropriate. Figure 2. Normative and informative elements of the medical device software development PRM and PAM Capability dimension of the Medical Device Software Development PAM is derived directly from ISO/IEC together with the Capability Levels, Process Attributes, Generic Practices, Generic Resources and Generic Work Products. 1.6 EuroSPI 2014
7 4 Discussion One of the biggest challenges in integrating requirements and informative information from various sources is to do with the structure and terminology used in standards. Although ISO/IEC describes a uniform structure for process models, this has not been widely adopted quite yet. Some of the standards list their requirements in activities distinguishable as requirements only by the verb used in that sentence, e.g. shall, should or are. Natural language offered another challenge in the integration of requirements from various sources. Terms like define, identify, document, record, and establish have each got a different meaning in some standards but in other standards they can be all be summed up under the term establish. It took many iterations of constant comparison before reaching a result that both reviewers were satisfied with. The terminology of risk management in medical device standards has a different meaning from risk management in the generic software development standards where the risks are mostly related to project budget and schedule. In generic software development standards, safety engineering and safety management correspond to the product risk management central to any safety critical domain software development. Deciding on the terminology to adopt in the single best practice framework has been a great challenge. On one hand, the terminology should be the one that the safety critical domain experts use every day in their work as they will be applying the framework. At the same time, the terminology should be comprehensible for software developers across different domains allowing the latter to move into a safety critical software development. Another significant challenge in integrating various requirements from different sources is the interface between systems and software levels. This is a challenge often faced in embedded software development. In our PAM, there are both system and software life cycle processes and for embedded software development, the interface between these levels should be very strong. One way to strengthen the interface is to trace requirements from users throughout the development to validation ensuring that the user gets exactly what he or she needed. In order to further strengthen the interface between the software and system level development processes, this traceability should be bilateral, meaning that not only should you be able to trace the user requirements through system and software requirements specification to the final product, but you should also be able to trace every feature of the product and software item back to the user needs. 5 Conclusions and Future Works The medical device software development domain is filled with regulations that software development organisations need to comply with in order to market their products. In this paper we have described these regulatory standards together with the generic software development standards, further detailing how we have integrated requirements from both into a best practice framework. This framework can be used for medical device software development process assessments on both system and software level. The framework provides visibility of compliance of the organisation s processes with the requirements from all the source standards of the framework. This will allow the medical device manufacturer to select the supplier that focuses on the improvement of their medical device software development and adopts the best practices derived from the set of required standards. At the time of submitting this paper, the framework is being validated in industry. The framework has been piloted in the first medical device companies with the aim to gather feedback from medical device software developers and to improve the framework based on this feedback before its official launch later this year. Acknowledgment. This research is supported by Enterprise Ireland and the European Regional Development Fund (ERDF) under the National Strategic Reference Framework (NSRF) , grant number CF/2012/2631, and in part by the Science Foundation Ireland (SFI) Stokes Lectureship Programme, grant number 07/SK/I1299, and the SFI Principal Investigator Programme, grant number 08/IN.1/I2030 (the funding of this project was awarded by Science Foundation Ireland under a cofunding initiative by the Irish Government and European Regional Development Fund). EuroSPI
8 6 Literature 1. Feiler, P. and W. Humphrey Software Process Development and Enactment: Concepts and Definitions DeMarco, T. and B. Boehm, The agile methods fray. IEEE Computer, (6): p FDA. Chapter I - Food and drug administration, department of health and human services subchapter H - Medical devices, Part Quality system regulation. [cited ]; Available from: 4. European Commission, Directive 93/42/EEC of the European Parliament and of the Council concerning medical devices, in OJ o L 247 of : European Commission, Brussels, Belgium. 5. European Commission, Council directive 90/385/EEC on active implantable medical devices (AIMDD). 1990: Brussels, Belgium. 6. European Commission, Directive 98/79/EC of the european parliament and of the council of 27 october 1998 on in vitro diagnostic medical devices. 1998: Brussels, Belgium. 7. European Commission, Directive 2007/47/EC of the European Parliament and of the Council concerning medical devices, in OJ no L 247 of , EC: Brussels, Belgium. 8. ISO, ISO 13485: Medical Devices - Quality Management Systems - Requirements for Regulatory Purposes. 2003, ISO: Geneva, Switzerland. 9. ISO, ISO 9001: Quality Management Systems - Requirements. 2000: Geneva, Switzerland. 10. IEC, IEC 62304: Medical Device Software - Software Life-Cycle Processes. 2006, IEC: Geneva, Switzerland. 11. ISO/IEC, ISO/IEC 12207: Information Technology - Software Life-Cycle Processes. 1995, ISO/IEC: Geneva, Switzerland. 12. ISO/IEC, ISO/IEC 12207: Systems and Software Engineering - Software life cycle processes. 2008, ISO/IEC: Geneva, Switzerland. 13. ISO/IEC , Information technology - Software process assessment - A reference model for processes and process capability, in ISO, ISO Medical Devices - Application of Risk Management to Medical Devices 2009, ISO: Geneva, Switzerland. 15. IEC, IEC TR Medical Device Software - Part 1: Guidance on the Application of ISO to Medical Device Software. 2009, IEC: Geneva, Switzerland. 16. IEC, IEC Medical electrical equipment Part 1: General requirements for basic safety and essential performance 2005, IEC: Geneva, Switzerland. 17. IEC, IEC Medical devices - Application of usability engineering to medical devices. 2007, IEC: Geneva, Switzerland. 18. ISO/IEC, ISO/IEC Systems and Software Engineering - Life Cycle Management - Guidelines for Process Description. 2010: Geneva, Switzerland. 19. Clarke, P. and R.V. O'Connor, The situational factors that affect the software development process: Towards a comprehensive reference framework. Information and Software Technology, (5): p Corbin, J. and A. Strauss, Basics of Qualitative Research. 2008, Thousand Oaks, CA, USA: Sage Publications. 21. FDA, Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices p FDA, General Principles of Software Validation; Final Guidance for Industry and FDA Staff p FDA, Guidance for industry, FDA reviewers and compliance on - Off-The-Shelf Software Use in Medical Devices p EuroSPI 2014
9 Author CVs Dr. Marion Lepmets Dr. Marion Lepmets is a Senior Research Fellow at the Regulated Software Research Centre in Dundalk Institute of Technology and a member of the Irish Software Engineering Research Centre (Lero). Her PhD and post-doc research focused on the impact of process model implementation and of process assessment on process improvement success, respectively. Her current research is about the development of the process reference and process assessment models for medical device software development. She is also involved in the development of software engineering standards in the International Standardization Organization (ISO/IEC JTC1 SC7). Dr. Paul Clarke Dr. Paul Clarke is a Research Manager in the Regulated Software Research Centre based at DkIT and a Research Fellow with Lero the Irish Software Engineering Research Centre. Primary among Paul s present research interests is the establishment of a best practice framework for medical device software development. Dr. Fergal McCaffery Dr Fergal Mc Caffery is a Science Foundation Ireland (SFI) Principal Investigator. He is a Senior Lecturer in the Department of Computing and Mathematics, Dundalk Institute of Technology (DkIT). He is Director of the Regulated Software Research Centre in DkIT and the Medical Device Software Engineering competency area in Lero. He has been awarded SFI funding through the Stokes Lectureship, Principal Investigator and CSET Programmes to research the area of medical device software. He has published over 150 peer-reviewed conference and journal papers and is on the editorial board/programme committee for a number of leading software engineering conferences and journals. Anita Finnegan Alec Dorling Anita Finnegan is a Senior Software QMS Researcher in the Regulated Software Research Centre based at DkIT and a member of Lero the Irish Software Engineering Research Centre. Anita s primary focus is establishing the relationship between QMS requirements and software development requirements. Her PhD research addresses the development of a framework for the security assurance of medical devices using cybersecurity assurance cases. Alec Dorling is a member of the research team at the Regulated Software Research Centre in Dundalk Institute of Technology and a member of the Irish Software Engineering Research Centre (Lero). He is the ISO convener of the ISO/IEC series and ISO/IEC 330xx family of standards on Process Assessment, and the international project leader of SPICE (Software Process Improvement and Capability determination). He has held key positions in software engineering at both national and European levels at IVF s Centre for Software Engineering in Sweden, IT Research and Technology Transfer Centre at the University of Boras in Sweden, European Software Institute in Spain and the National Computing Centre in the UK. He is on the editorial board/programme committee for a number of leading software engineering conferences and journals. EuroSPI
A Methodology for Software Process Improvement Roadmaps for Regulated Domains Example with ISO 62366
A Methodology for Software Process Improvement Roadmaps for Regulated Domains Example with ISO 62366 Derek Flood, Fergal Mc Caffery, Valentine Casey, Gilbert Regan Dundalk Institute of Technology, {Derek.flood,
Software Process Improvement to assist Medical Device Software Development Organisations to comply with the amendments to the Medical Device Directive
Software Process Improvement to assist Medical Device Software Development Organisations to comply with the amendments to the Medical Device Directive Martin Mc Hugh, Fergal Mc Caffery, Valentine Casey
A Security Risk Management Framework for Networked Medical Devices
A Security Risk Management Framework for Networked Medical Devices Anita Finnegan, Fergal Mc Caffery, Gerry Coleman Regulated Software Research Centre & Lero Dundalk Institute of Technology Dundalk THE
WHITEPAPER: SOFTWARE APPS AS MEDICAL DEVICES THE REGULATORY LANDSCAPE
WHITEPAPER: SOFTWARE APPS AS MEDICAL DEVICES THE REGULATORY LANDSCAPE White paper produced by Maetrics For more information, please contact global sales +1 610 458 9312 +1 877 623 8742 [email protected]
Medical Device Software Standards for Safety and Regulatory Compliance
Medical Device Software Standards for Safety and Regulatory Compliance Sherman Eagles +1 612-865-0107 [email protected] www.softwarecpr.com Assuring safe software SAFE All hazards have been addressed
Medical Device Software Do You Understand How Software is Regulated?
Medical Device Software Do You Understand How Software is Regulated? By Gregory Martin Agenda Relevant directives, standards, and guidance documents recommended to develop, maintain, and validate medical
Medical Devices. Notified Bodies and the CE certification Process for Medical Devices. European Surgical Robotics Demonstration Day
Medical Devices Notified Bodies and the CE certification Process for Medical Devices European Surgical Robotics Demonstration Day 27 th March 2014, Leuven, Belgium 1 Bart Mersseman Product Manager Medical
CONSOLIDATED VERSION IEC 62304. Medical device software Software life cycle processes. colour inside. Edition 1.1 2015-06
IEC 62304 CONSOLIDATED VERSION Edition 1.1 2015-06 colour inside Medical device software life cycle processes INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 11.040 ISBN 978-2-8322-2765-7 Warning! Make sure
How To Write Software
1 Medical Device Software - Software Life Cycle Processes IEC 62304 2 Credits John F. Murray Software Compliance Expert U.S. Food and Drug Administration Marcie R. Williams Medical Device Fellow Ph.D.
Effective Software Verification for Medical Devices
STERLINGTECH AND KLOCWORK WHITE PAPER NOVEMBER 2009 Effective Software Verification for Medical Devices Achieving compliance and meeting productivity goals with static analysis In addition to producing
GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES
GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES Foreword This guidance document is informative and advisory and has no legal authority. Individual national enforcement authorities are bound
Navigating the New EU Rules for Medical Device Software
Navigating the New EU Rules for Medical Device Software Mathias Klümper and Erik Vollebregt examine how European Directive 2007/47/EC will affect requirements for medical device software. Directive 2007/47/EC
UNDERSTANDING THE EC DIRECTIVE 98/79/EC ON IN VITRO DIAGNOSTIC MEDICAL DEVICES
UNDERSTANDING THE EC DIRECTIVE 98/79/EC ON IN VITRO DIAGNOSTIC MEDICAL DEVICES A WHITE PAPER ON THE REQUIREMENTS, REGULATIONS AND OPPORTUNITIES CONTAINED IN EC DIRECTIVE 98/79/EC AND A BRIEF COMPARISON
Introduction into IEC 62304 Software life cycle for medical devices
Introduction into IEC 62304 Software life cycle for medical devices Christoph Gerber 4. September 2008 SPIQ 9/5/2008 1 Agenda Current Picture Regulatory requirements for medical device software IEC 62304
ELECTROTECHNIQUE IEC INTERNATIONALE 61508-3 INTERNATIONAL ELECTROTECHNICAL
61508-3 ª IEC: 1997 1 Version 12.0 05/12/97 COMMISSION CEI ELECTROTECHNIQUE IEC INTERNATIONALE 61508-3 INTERNATIONAL ELECTROTECHNICAL COMMISSION Functional safety of electrical/electronic/ programmable
An Overview of ISO/IEC 27000 family of Information Security Management System Standards
What is ISO/IEC 27001? The ISO/IEC 27001 standard, published by the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC), is known as Information
CE Marking: Your Key to Entering the European Market
CE Marking: Your Key to Entering the European Market N. Gerard Zapiain U.S. Department of Commerce International Trade Administration Office of Microelectronics, Medical Equipment and Instrumentation I.
International standards and guidance that address Medical Device Software
International standards and guidance that address Medical Device Software Sherman Eagles Technical Fellow Medtronic CRDM Convener IEC 62A/ISO 210 JWG3 Co-convener IEC 62A/ISO 215 JWG7 Standards in the
The Emerging ISO International Standard for Certification of Software Engineering Professionals
The Emerging ISO International Standard for Certification of Software Engineering Professionals Juan Garbajosa Universidad Politécnica de Madrid - Technical University of Madrid (UPM). E.U. Informática.
MEDICAL DEVICE Cybersecurity.
MEDICAL DEVICE Cybersecurity. 2 MEDICAL DEVICE CYBERSECURITY Introduction Wireless technology and the software in medical devices have greatly increased healthcare providers abilities to efficiently and
The New Paradigm for Medical Device Safety. Addressing the Requirements of IEC 60601-1 Edition 3.1
The New Paradigm for Medical Device Safety Addressing the Requirements of IEC 60601-1 Edition 3.1 Medical devices play a vital role in the diagnosis and treatment of most health-related conditions, and
Implementing COBIT based Process Assessment Model for Evaluating IT Controls
Implementing COBIT based Process Assessment Model for Evaluating IT Controls By János Ivanyos, Memolux Ltd. (H) Introduction New generations of governance models referring to either IT or Internal Control
QSS 0: Products and Services without Bespoke Contracts.
QSS 0: Products and Services without Bespoke Contracts. Amendment History Version Date Status v.1 Dec 2014 Updated For 2015 deployment Table of Contents 1. DEFINITIONS 3 2. INTRODUCTION 3 3. WORKING WITH
Revision of ISO 9001 Quality Management Systems Requirements
Revision of ISO 9001 Quality Management Systems Requirements Frequently Asked Questions When will the new ISO 9001 be published? The international standard ISO 9001:2008 Quality management systems Requirements
MANAGEMENT SYSTEM FOR A NUCLEAR FACILITY
GUIDE YVL A.3 / 2 June 2014 MANAGEMENT SYSTEM FOR A NUCLEAR FACILITY 1 Introduction 5 2 Scope of application 6 3 Management system 6 3.1 Planning, implementation, maintenance, and improvement of the management
ISO/IEC 15504 Part 2 provides the following copyright release:
Copyright Notice This document reproduces relevant material from ISO/IEC 15504:2003 Information Technology Process Assessment Part 2: Performing an assessment and ISO/IEC FCD 15504:2005 Information Technology
Creating Competitive Advantage: The role for ALM in the PLM world
Creating Competitive Advantage: The role for ALM in the PLM world Michael Azoff Principal Analyst, Ovum [email protected] Version 9 Oct, 2014 1 Copyright Ovum. All rights reserved. Ovum is a subsidiary
Applying Integrated Risk Management Scenarios for Improving Enterprise Governance
Applying Integrated Risk Management Scenarios for Improving Enterprise Governance János Ivanyos Trusted Business Partners Ltd, Budapest, Hungary, [email protected] Abstract: The term of scenario is used
CP14 ISSUE 5 DATED 1 st OCTOBER 2015 BINDT Audit Procedure Conformity Assessment and Certification/Verification of Management Systems
Certification Services Division Newton Building, St George s Avenue Northampton, NN2 6JB United Kingdom Tel: +44(0)1604-893-811. Fax: +44(0)1604-893-868. E-mail: [email protected] CP14 ISSUE 5 DATED 1 st OCTOBER
Emerging Device Topics for Regulatory Consideration.. Janine Jamieson May 2015
Emerging Device Topics for Regulatory Consideration. Janine Jamieson May 2015 Disclaimer These are my personal views and not necessarily those of MHRA as an organisation. 2 European regulation of combination
A Risk Management Capability Model for use in Medical Device Companies
A Risk Management Capability Model for use in Medical Device Companies John Burton Vitalograph Ltd. Gort Rd. Business Park Ennis Ireland 353.65.686471 [email protected] Fergal Mc Caffery Lero
Medical Device Directive 2007/47/EC What is New? Are we moving towards Drug Rules?
Medical Device Directive 2007/47/EC What is New? Are we moving towards Drug Rules? CEMO Congress, Paris, February 3rd, 2011 Dr. Martine Dehlinger-Kremer Vice President Global Regulatory Affairs Agenda
International Organization for Standardization TC 215 Health Informatics. Audrey Dickerson, RN MS ISO/TC 215 Secretary
International Organization for Standardization TC 215 Health Informatics Audrey Dickerson, RN MS ISO/TC 215 Secretary 1 Topics Introduction to ISO TC 215, Health Informatics Definitions Structure Membership
Frequently Asked Questions. Unannounced audits for manufacturers of CE-marked medical devices. 720 DM 0701-53a Rev 1 2014/10/02
Frequently Asked Questions Unannounced audits for manufacturers of CE-marked medical devices 720 DM 0701-53a Rev 1 2014/10/02 What is an unannounced audit?... 6 Are unannounced audits part of a new requirement?...
Systems and software engineering Lifecycle profiles for Very Small Entities (VSEs) Part 5-6-2:
TECHNICAL REPORT ISO/IEC TR 29110-5-6-2 First edition 2014-08-15 Systems and software engineering Lifecycle profiles for Very Small Entities (VSEs) Part 5-6-2: Systems engineering Management and engineering
Implementation of ANSI/AAMI/IEC 62304 Medical Device Software Lifecycle Processes.
Implementation of ANSI/AAMI/IEC 62304 Medical Device Software Lifecycle Processes.. www.pharmout.net Page 1 of 15 Version-02 1. Scope 1.1. Purpose This paper reviews the implementation of the ANSI/AAMI/IEC
An introduction to the regulation of apps and wearables as medical devices
An introduction to the regulation of apps and wearables as medical devices Introduction Phones are increasingly equipped with a range of devices capable of being used as sensors, including gyroscopes,
CDRH Regulated Software
CDRH Regulated Software An Introduction John F. Murray Jr. CDRH Software Compliance Expert CDRH Regulates Software in the following areas Medical Devices Automation of Production Systems Automation of
ISO/IEC 15504 Part 10 Safety Extension. Giuseppe Lami Istituto di Scienza e Tecnologie dell Informazione Consiglio Nezionale delle Ricerche Pisa
ISO/IEC 15504 Part 10 Safety Extension Giuseppe Lami Istituto di Scienza e Tecnologie dell Informazione Consiglio Nezionale delle Ricerche Pisa ISO/IEC 15504 Part 10 talk overview Foundation of the draft
MDEP Generic Common Position No DICWG 02
MDEP Generic Common Position No DICWG 02 Related to: Digital Instrumentation and Controls Working Group activities COMMON POSITION ON SOFTWARE TOOLS FOR THE DEVELOPMENT OF SOFTWARE FOR SAFETY SYSTEMS 1
IBM Rational systems and software solutions for the medical device industry
IBM Software August 2011 IBM Rational systems and software solutions for the medical device industry Improve processes, manage IEC 61508 and IEC 62304 standards, develop quality products Highlights Manage
Health Informatics Application of clinical risk management to the manufacture of health software Formerly ISO/TS 29321:2008(E) DSCN14/2009
Health Informatics Application of clinical risk management to the manufacture of health software (formerly ISO/TS 29321:2008(E)) DSCN14/2009 Programme Sub-Prog / Project NPFIT Clinical Safety Document
2015. All rights reserved.
DOCUMENT: Future AAMI/IEC 62304:2006/AMD1, 18-August-2015 Final Draft International Standard for Vote, Amendment 1 to IEC 62304: Medical device software Software life cycle processes. Public Review Draft
COMMISSION OF THE EUROPEAN COMMUNITIES. Proposal for a DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL
COMMISSION OF THE EUROPEAN COMMUNITIES Brussels, 24.04.2001 COM(2001) 213 final 2001/0095 (COD) Proposal for a DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL on the supplementary supervision of
Software Project Management in Very Small Entities with ISO/IEC 29110
Software Project Management in Very Small Entities with ISO/IEC 29110 Rory V. O Connor 1, 2 Claude Y. Laporte 3 1 Lero, the Irish Software Engineering Research Centre, Ireland 2 Dublin City University,
This document is a preview generated by EVS
TECHNICAL REPORT ISO/IEC TR 20000-9 First edition 2015-02-15 Information technology Service management Part 9: Guidance on the application of ISO/IEC 20000-1 to cloud services Technologies de l information
Want to know more about the Notified Body?
NBG/V 2/07/14 BSI Notified Body (0086) Kitemark Court Davy Avenue Knowlhill Milton Keynes MK5 8PP United Kingdom T: +44 845 080 9000 E: [email protected] W: medicaldevices.bsigroup.com Want
COMMITTEE ON STANDARDS AND TECHNICAL REGULATIONS (98/34 COMMITTEE)
EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Regulatory Policy Standardisation Brussels, 9 th November 2005 Doc.: 34/2005 Rev. 1 EN COMMITTEE ON STANDARDS AND TECHNICAL REGULATIONS (98/34
EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL. Space, Security and GMES Security Research and Development
Ref. Ares(2011)193990-22/02/2011 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Space, Security and GMES Security Research and Development Brussels, 17 th February 2011 M/487 EN PROGRAMMING
Application of software product quality international standards through software development life cycle
Central Page 284 of 296 Application of software product quality international standards through software development life cycle Mladen Hosni, Valentina Kirinić Faculty of Organization and Informatics University
Information Security ISO Standards. Feb 11, 2015. Glen Bruce Director, Enterprise Risk Security & Privacy
Information Security ISO Standards Feb 11, 2015 Glen Bruce Director, Enterprise Risk Security & Privacy Agenda 1. Introduction Information security risks and requirements 2. Information Security Management
This interpretation of the revised Annex
Reprinted from PHARMACEUTICAL ENGINEERING The Official Magazine of ISPE July/August 2011, Vol. 31 No. 4 www.ispe.org Copyright ISPE 2011 The ISPE GAMP Community of Practice (COP) provides its interpretation
Preparation of a Rail Safety Management System Guideline
Preparation of a Rail Safety Management System Guideline Page 1 of 99 Version History Version No. Approved by Date approved Review date 1 By 20 January 2014 Guideline for Preparation of a Safety Management
Functional Safety Management: As Easy As (SIL) 1, 2, 3
Functional Safety Management: As Easy As (SIL) 1, 2, 3 Abstract This paper outlines the need for planning in functional safety management. Recent events such as the Montara blowout and the Deepwater Horizon
Guide for Custom-Made Dental Device Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994
Guide for Custom-Made Dental Device Manufacturers on Compliance with European Communities (Medical SUR-G0014-1 12 NOVEMBER 2013 This guide does not purport to be an interpretation of law and/or regulations
Medical Certification: Bringing genomic microcores to clinical use OI- VF- WP- 011
Medical Certification: Bringing genomic microcores to clinical use VoltedFlow GmbH Industriestrasse 23, 6055, Alpnach Dorf, Switzerland 1 Summary VoltedFlow has developed solutions to vastly speed up DNA
* * * Initial Provisions for. CHAPTER [ ] - Regulatory Cooperation
REMARKS: This is an initial textual proposal for a draft Chapter on Regulatory Cooperation that the Commission intends to submit to the US on Friday, 30 January, in preparation of the 8 th round of TTIP
Medical Devices: CE Marking Step-by Step
Medical Devices: CE Marking Step-by Step Sylvia Mohr Standards Specialist U.S. Mission to the European Union 1 Introduction CE marking in 8 Steps Overview intended purpose - technical documentation classification
ISO/IEC 9126-1 Software Product Quality Model
Why do current systems fail? Standish Group found that 51% of projects failed 31% were partially successful Main causes were poor user requirements: 13.1% Incomplete requirements 12.4% Lack of user involvement
Guidance for manufacturers and Notified Bodies on reporting of Design Changes and Changes of the Quality System
NBOG s Best Practice Guide applicable for AIMDD, MDD, and IVDD 2014-3 Guidance for manufacturers and Notified Bodies on reporting of Design Changes and Changes of the Quality System 1 Introduction The
EBA FINAL draft Regulatory Technical Standards
EBA/RTS/2015/03 03 July 2015 EBA FINAL draft Regulatory Technical Standards on resolution colleges under Article 88(7) of Directive 2014/59/EU Contents 1. Executive summary 3 2. Background and rationale
BSI Unannounced Audits
BSI Unannounced Audits Frequently Asked Questions (FAQs) BSI Group Kitemark Court, Davy Avenue Knowlhill, Milton Keynes MK5 8PP, United Kingdom T: +44 845 080 900 [email protected] bsigroup.com
RAPS ONLINE UNIVERSITY
RAPS ONLINE UNIVERSITY Practical education and training for business success. For regulatory professionals, there is only one name to know and trust for online education and training RAPS Online University.
Quality Management System Certification. Understanding Quality Management System (QMS) certification
Quality Management System Certification Understanding Quality Management System (QMS) certification The medical device manufacturing sector is one of the most regulated sectors in which significant quality
System Basics for the certification of sustainable biomass and bioenergy
ISCC 201 System Basics System Basics for the certification of sustainable biomass and bioenergy ISCC 11-03-15 V 2.3-EU Copyright notice ISCC 2011 This ISCC document is protected by copyright. It is freely
For more information, contact Joe Lewelling, AAMI's VP of Standards Development & Emerging Technologies, at [email protected].
For more information, contact Joe Lewelling, AAMI's VP of Standards Development & Emerging Technologies, at [email protected]. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
Reporting Changes to your Notified Body
Reporting Changes to your Notified Body Vicky Medley - Head of QMS, Medical Devices September 2015 1) Requirements & Guidance 2) Reporting Changes - What, When, Why & How 3) Some examples 4) Summary &
COCIR contribution to the public consultation on Personal Data Protection in the EU 1
COCIR contribution to the public consultation on Personal Data Protection in the EU 1 European Coordination Committee of the Radiological, Electromedical and Healthcare IT Industry Bd. A. Reyers 80, 1030
Guidelines on operational functioning of colleges
EIOPA-BoS-14/146 EN Guidelines on operational functioning of colleges EIOPA Westhafen Tower, Westhafenplatz 1-60327 Frankfurt Germany - Tel. + 49 69-951119-20; Fax. + 49 69-951119-19; email: [email protected]
BSI Road Show: September 8 th to 15 th, 2014
BSI Road Show: September 8 th to 15 th, 2014 Post Market Surveillance (including PMCF): common non compliances Ibim Tariah Ph.D Technical Director, Healthcare Solutions Itoro Udofia Ph.D Global Head, Orthopaedics
Medical Device Training Program 2015
Medical Device Training Introduction Supplementary training and education is often overlooked by medical device professionals until it is triggered by an upcoming FDA or Notified Body and/or ISO 13485
COMMISSION REGULATION. of 5.5.2011
EN EN EN EUROPEAN COMMISSION Brussels, 5.5.2011 C(2011) 2962 final COMMISSION REGULATION of 5.5.2011 on the technical specification for interoperability relating to the subsystem 'telematics applications
How To Know If A Mobile App Is A Medical Device
The Regulation of Medical Device Apps Prepared for West of England Academic Health Science Network and University of Bristol June 2014 June 2014 1 Table of Contents 1 Purpose...3 2 Scope...3 3 The Regulation
The Medical Products Agency s Working Group on Medical Information Systems. Project summary
The Medical Products Agency s Working Group on Medical Information Systems Project summary Proposal for guidelines regarding classification of software based information systems used in health care This
REPORT FROM THE COMMISSION TO THE EUROPEAN PARLIAMENT AND THE COUNCIL
EUROPEAN COMMISSION Brussels, 25.9.2014 COM(2014) 592 final REPORT FROM THE COMMISSION TO THE EUROPEAN PARLIAMENT AND THE COUNCIL on the implementation in the period from 4 December 2011 until 31 December
How to Use the Design Process to Manage Risk: Elements of Design Controls and Why It Matters
environmental failure analysis & prevention health technology development How to Use the Design Process to Manage Risk: Elements of Design Controls and Why It Matters Kevin L. Ong, Ph.D., P.E. Managing
Understanding Medical Device Regulation for mhealth A Guide for Mobile Operators
for mhealth A Guide for Mobile Operators 1 Foreword Mobile technologies will make a significant contribution to addressing the enormous challenges of healthcare provision worldwide. Early efforts in mobile
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO/IEC/ IEEE 42010 First edition 2011-12-01 Systems and software engineering Architecture description Ingénierie des systèmes et des logiciels Description de l'architecture Reference
EIOPACP 13/011. Guidelines on PreApplication of Internal Models
EIOPACP 13/011 Guidelines on PreApplication of Internal Models EIOPA Westhafen Tower, Westhafenplatz 1 60327 Frankfurt Germany Tel. + 49 6995111920; Fax. + 49 6995111919; site: www.eiopa.europa.eu Guidelines