1 Development of an atmospheric datamanagement system for underground coal mines by Z. Agioutantis*, K. Luxbacher, M. Karmis, and S. Schafrik Synopsis With increasing demand for real-time monitoring of mine parameters, the requirement for appropriate data management in many mining applications is also increasing. This includes atmospheric monitoring in underground coal and metal mines. Although a number of different (real-time) monitoring systems have been installed in underground mines, they all typically share the same systems or sub-systems, where each sub-system may include both custom hardware and / or software components. In addition, monitoring components installed in underground coal mines in the USA should also be intrinsically safe and approved by the US Mine Safety and Health Administration. Real-time analysis adds complexity to the system since data validation and storage should be completed independently of filtering, data reduction operations, or visualization. Real-time processing may include statistical evaluation, trending, cross-correlation, and real-time alarm or warning generation. This paper presents the concept and design of an integrated system under development for atmospheric monitoring in US coal mines. Keywords mine ventilation, real-time monitoring, data management. Introduction The monitoring of atmospheric conditions in underground coal mines is an important task that helps mine operators run the ventilation systems in a more efficient manner, therefore ensuring a safe environment for all mine personnel. The layout of the sensors in each mine depends on mine geometry, the design of the ventilation system, the availability of power and communication lines to each sensor location, and other factors. Currently, several real-time monitoring techniques are available that allow mine operators to monitor all ventilation parameters, such as air flow, air velocity, pressure drop, and gas concentration at various locations throughout a mine. Although advances in electronics and data transmission systems have led to progress in this field in recent years, monitoring of atmospheric conditions still presents challenges due to the limitations in current technologies in terms of accuracy, response time, range, sensitivity, and ruggedness of equipment. In the USA, atmospheric monitoring in underground coal mines is not only mandatory, but systems should be designed and implemented according to existing regulations, i.e., Title 30 of the Code of Federal Regulations (CFR). More specifically, under current atmospheric monitoring system (AMS) regulations (CFR ), data archiving is not required. The regulation states that records must be kept regarding alert or alarm signals, AMS malfunctions, and seven-day tests of alert and alarm signals conducted. The records must note the person that recorded the information, and be kept in a secure book or electronic system that is not susceptible to alteration. These records must be kept for one year at a surface location at the mine and be available for inspection by miners and authorized representatives of the Secretary (CFR ). The required records are limited to alert or alarm signals, malfunctions, system tests, and calibration. Furthermore, in the case of coal mines, the equipment should be permissible i.e. it should meet the specifications by the US Mine Safety and Health Administration (MSHA) for the construction and maintenance of such equipment, to assure that it will not cause a mine explosion or mine fire. Depending on the size and type of the underground mine, atmospheric monitoring should gather data that covers several different parameters that characterize the atmospheric conditions underground, including (but not limited to) concentrations of various gases (CO, CO 2, CH 4, etc.), wet and dry temperature, humidity, barometric pressure, air flow, fan performance indicators, air velocity, and total air pressure loss. * University of Kentucky, USA. Virginia Center for Coal and Energy Research, Virginia Tech, USA. The Southern African Institute of Mining and Metallurgy, ISSN This paper was first presented at, A Southern African Silver Anniversary, 2014 SOMP Annual Meeting, June 2014, The Maslow Hotel, Sandton, Gauteng. The Journal of The Southern African Institute of Mining and Metallurgy VOLUME 114 DECEMBER
2 Proper monitoring becomes even more important in the case of coal mines, where high methane concentrations present a hazard and/or high CO indicates development of a fire. In addition to everyday operations, atmospheric monitoring can be used to detect incidents such as explosions behind seals, a methane ignition at the face, a belt fire, etc. However, it should be noted that atmospheric monitoring sensors commonly used to detect the parameters of interest may be currently limited in response time and sensitivity. Current monitoring technologies in US coal mines A simplified layout of a typical system currently installed in US coal mines is shown in Figure 1. Any equipment installed in the mine area should be permissible. Data transmission is currently accomplished mainly via fibre optic lines using commercial protocols such as ethernet over TCP/IP. Nearsensor communication is often via copper cable to a fibre junction box The stations that provide power and coordinate data transmission to the surface are usually driven by programmable logic controllers (PLCs) that allow smart communication between the surface computer(s) and the underground equipment. PLCs can usually report on the status of communications with a sensor, the status of a sensor, and keep track of multiple sensors per station. Power is usually transmitted to sensors via the same cable that gathers data. Data is usually converted from analog to digital at the sensor level and is transmitted as digital information to the surface. At the surface location, dedicated computer units communicate with the PLCs at mine level and coordinate data flow to a database and a digital display system available to operators (Figure 2). These systems are typically called human-machine interfaces (HMIs) or supervisory control and data acquisition (SCADA) systems. Operators can interface with PLCs through these systems, e.g., acknowledge alarms, start / stop equipment, etc. Figure 1 Simplified layout of sensor deployment in US coal mines Figure 2 Data acquisition for atmospheric monitoring in coal mines 1060 DECEMBER 2014 VOLUME 114 The Journal of The Southern African Institute of Mining and Metallurgy
3 In terms of hardware, such systems typically include three basic component groups: (a) the sensors (and data loggers / converters) responsible for data acquisition, (b) the communication sub-system responsible for transmitting data to a central location, and (c) the processing and storage subsystem, comprising one or more computer units, responsible for data processing and temporary or permanent data storage. In addition, software operating off the processing and storage sub-system is responsible for coordinating data acquisition, validating collected data, visualization, data analysis, and report generation. Such systems are usually built to comply with MSHA regulations as stated above, and lack advanced data analysis capabilities such as variable cross-correlation, correlation with variables external to the database, etc. Furthermore, a typical database system implemented on such systems is configured to store data on a moving 7-day or 14-day window, i.e. old data is erased every day. In some system implementations, data for selected monitored parameters is exported to daily, weekly, or other files for archiving and storage. It is obvious that the data in such files cannot be easily managed and analysed unless it is stored in a common database. Data management and analysis in mine ventilation is perhaps most heavily utilized in metal and nonmetal mines that have implemented ventilation on demand (VOD). Many of the same management and analysis challenges have been identified, such as the inherent complexity of mine ventilation systems, and development of robust data collection, storage, and management (e.g. g Meyer, 2008; Tonnos and Allen, 2008). Additionally, these mines have demonstrated measureable improvements in safety and efficiency through application of such systems (e.g., g Gunderson et al., 2005; O Connor, 2008; Karsten and Mackay, 2012) Although VOD is not applicable to underground coal mines in the USA, due to restrictions in the amount of airflow change allowed while people are underground (CFR ), the data management and analysis methods developed for application of VOD are certainly applicable. Database design A relational database application was developed that has built-in data capture and analysis capabilities. This application, called Atmospheric Monitoring Analysis and Database management (or AMANDA), is specifically designed for AMS data. The capabilities of the system are discussed in this section. Data management of an AMS should ensure that the integrity of historical data is maintained. Underground mines generate a large range of data, and this presents a challenge for the AMS database system, especially with systems that have many sensors reporting a large quantity of data. For instance, assume that each data record corresponding to a single measurement value from a given sensor may require a storage space of about 50 bytes (date-time stamp, tag number, project number, value, etc.). In typical applications, data may be gathered every few seconds. If one data value is sampled every ten seconds, there would be approximately MB of data generated per sensor per day. For a mine with 20 sensors, approximately 8.2 MB of data is generated daily. One year of data with only 20 sensors corresponds to approximately 3.0 GB. Large mining operations and processing plants may incorporate several hundreds (even thousands) of sensors throughout the operation to control and monitor devices. If a large mining operation deploys 300 sensors and its processing plant utilizes 400 sensors, with a sampling frequency of 10 seconds, those sensors would generate approximately 288 MB daily and 105 GB each year. This estimate does not include other data that can illuminate trends further, e.g., measures of loads on mechanized cutting and hauling equipment, physical locations of people and equipment via tracking technology, and maintenance, surveying, and production data. Storage of this data presents a set of challenges; those with fairly simple solutions are not discussed in this paper. Management and utilization of the data is critical to the operation. Optimizing the placement of monitoring systems to acquire the most critical information, and transmitting the information to a centralized location with a sophisticated storage method has value only if the data can be understood and utilized by a decision-maker. The AMANDA data management system has a number of subsystems, e.g. for data acquisition; data analysis, validation, and storage; visualization and reporting of the data; alarm generation; and tools for statistical evaluation and cross-correlation. Thus, the database was designed with the following characteristics: Deployable on a 64-bit system to allow for large files Built on a relational database model Implemented as a client / server system Allows multiple indexing of the data records to assure a quick response to queries. In addition, the data management application allows: Data collection for multiple projects; a project is defined as a collection of sensor data as implemented in a single mine database A fully parametric definition of the sensor types that will be used in a project. Each parameter measured by a PLC-driven sensor is called a tag; multiple user-defined tags can be defined per project, and a unique sensor type can be assigned per tag Importing of data files exported by current AMS implementations (Figure 3) Importing of external data such as barometric pressure or temperature as recorded by weather stations available on the internet (Figure 3) Identification of missing data Setting of individual warning and alarm thresholds per tag. Figure 3 presents a simplified diagram that shows data flow from the sensors to the currently available Mine Database. AMANDA is external to this data flow and only reads data available by automatic export by the mine system. AMANDA thus cannot directly or indirectly interfere with the installed data acquisition system. Data from a US coal mine was imported to the database (Griffin, 2013). In this coal mine, multiple methane and CO sensors have been installed, in addition to the usual sensors for fan, belt, and other operations. Data was available in DBF format on a daily basis. More specifically, for every day two files were generated by the existing system: a tag file, which The Journal of The Southern African Institute of Mining and Metallurgy VOLUME 114 DECEMBER
4 Figure 3 Data flow to the mine database and to the AMANDA database listed the tags or sensors that were monitored, and for which data was collected and saved; and the main data file (also in DBF format), which listed the data in columns. Each row represented measurements at a different timestamp. For each tag two columns were provided, one with the value read from the sensor and one with the status of the sensor. A typical daily file included 8600 rows (sampling about every 10 seconds) and over 80 columns which correspond to 40 sensors. Prior to data import, a project was defined and the sensors were added to the project. When daily data was imported, each data value and its time stamp were assigned to the corresponding sensor and project. There was no barometric pressure sensor installed at the mine at that time. Data from a nearby publicly available weather station was downloaded and imported into the database into a separate tag, which was assigned to the external sensor. During importing, data was not altered in any way. Erroneous values (i.e. negative or extreme values) were also imported. The user can isolate these values by flagging them, but the raw data is always available for inspection. Once data has been imported into the relational database, it is easy to select specific data groups for plotting and analysis. The program can plot any of the recorded tags versus time. Data can also be displayed in a continuous mode by displaying a moving window of one or multiple days. Figure 4 shows an example of ventilation fan motor amperes. The fan motor power consumption varies throughout daily operation, demonstrating that tracking fan performance can be just as important as monitoring underground gas levels. Fluctuations in the fan motor amperes can be due to the motor efficiency, outside temperature, air density, movement in mine openings, and a wide variety of other factors. Monitoring fan performance can also help the mine operator understand if changes in gas concentrations are related to fan performance. Fan performance is an example of a variable that can contribute to changes in gas concentration and must be analysed with other data to allow for the emergence of critical trends. Figures 5a and 5b show examples of superimposed data collected by two methane sensors (right axis, methane concentration in per cent) at two different mine locations on return airways (green and blue curves) and the surface barometric pressure (left axis, inches Hg). It can be seen that sudden decreases in the barometric pressure coincide with an immediate increase in the methane percentage in these two locations. The horizontal axis corresponds to a time period of 7 days. Although, the correlation of barometric pressure and methane concentration has been cited several times (Fauconnier, 1992; Lloyd and Cook 2004), with the new database management system this simple correlation by superposition was very easily accomplished. Figure 4 Monitoring of the electrical current on a fan motor over a three-day period 1062 DECEMBER 2014 VOLUME 114 The Journal of The Southern African Institute of Mining and Metallurgy
5 Figure 5 Superposition of barometric pressure and methane concentrations at two different locations for a time period of 7 days Summary and conclusions A new database management system was developed in order to facilitate the massive undertaking of maintaining, storing, reviewing, analysing, and interpreting large amounts of data generated daily by sensors installed in underground coal mines. The database is capable of handling multiple projects and multiple sensor sets per project. Data can also be imported from external sources. In terms of application development, current work is focusing on identifying and analysing peaks (or spikes) in a given time-series. While it is easy to visually identify peaks in a short time window, there is a need to formalize peak detection to determine whether these peaks correspond to significant increases or decreases. In terms of data analysis, the next step would be to correlate other collected parameters with each other, such as production and methane emissions, fan performance and barometric pressure or daily temperature variation, etc. This is a primary, but complex function; this data may be utilized to better characterize the behaviour of a mine environment, which is a complex engineered system. This includes determining and verifying causality (e.g. g falling barometric pressure, malfunctioning fan, increased production) when a parameter trends in an alarming manner (e.g. g rising methane concentrations), so that high-risk situations can be remediated. The importance of the human interface will be also examined. The most advanced human-computer interfaces in mining have generally been directed toward the stationary operator, or a person who has oversight of all the sensors in a mine. While communication via these interfaces is essential, and has led to improved safety and efficiency, many mine personnel do not have access to data that can allow them to better assess situations and make more informed decisions. The challenge is to design technology that is portable, rugged, and safe for use in underground coal mines, and to design software that rapidly conveys emerging data trends to mine personnel. These trends should allow personnel to anticipate system failure (e.g., ventilation, ground, equipment) or to verify safe conditions. An interface for the AMANDA software will be developed and assessed for ease of use, knowledge gains to the user, and speed of information uptake. Implementation of advanced monitoring and analysis systems in mines is challenging due to the dynamic nature and unique attributes of any single mine, but the gains in health and safety as a result of more informed decisionmaking are well worth the investment in resources and technology. References FAUCONNIER, C.J Fluctuations in barometric pressure as a contributory factor to gas explosions in South African mines. Journal of the South African Institute of Mining and Metallurgy, vol. 92, no. 5. pp GRIFFIN, K.R Utilization and Implementation of Atmospheric Monitoring Systems in United States Underground Coal Mines and Application of Risk Assessment. Doctoral dissertation. Virginia Tech, Blacksburg, VA. GUNDERSON, R.E., VON GLEHN, F.H., and W WILSON, R.W Improving the efficiency of mine ventilation and cooling systems through active control. 8th International Mine Ventilation Congress, Brisbane, Queensland, 6 8 July Gillies, A.D.S. (ed.). Australasian Institute of Mining and Metallurgy, Carlton, Victoria. 6 pp. KARSTENK, M. and MACKAY, L Underground environmental challenges in deep platinum mining and some suggested solutions. Platinum 2012, 5th International Platinum Conference A Catalyst for Change, Sun City, South Africa, September Southern African Institute of Mining and Metallurgy, Johannesburg. pp LLOYD, P.J.D. and COOK, A Methane release from South African coal mines. Journal of the South African Institute of Mining and Metallurgy, vol. 105, no. 8. pp MEYER, M.A Implementing a tracking and ventilation control system at Barrick Goldstrike s underground division. 12th U.S./North American Mine Ventilation Symposium, Reno, Nevada, 9 11 June Wallace, K. (ed.). Society for Mining, Metallurgy & Exploration, Englewood, CO. pp O CONNOR, D.F Ventilation on demand (VOD) auxiliary fan project Vale Inco Limited, Creighton Mine. 12th U.S./North American Mine Ventilation Symposium, Reno, Nevada, 9 11 June Wallace, K. (ed.). Society for Mining, Metallurgy & Exploration, Englewood, CO. pp TONNOS, A.M. and ALLEN, C Technology convergence for sustainable underground mine ventilation system control. 12th U.S./North American Mine Ventilation Symposium. Reno, Nevada, 9 11 June 2008 Wallace, K. (ed.). Society for Mining, Metallurgy & Exploration, Englewood, CO. pp US Department of Labor, Mine Safety and Health Administration Title 30, Code of Federal Regulations, Parts 1-199, Mineral Resources. The Journal of The Southern African Institute of Mining and Metallurgy VOLUME 114 DECEMBER
The Digital Mine Concept and perspectives
The Digital Mine Concept and perspectives PSI Production GmbH, Aschaffenburg, Germany Table of Content 1. Introdu ctio n... 3 2. Targets o f a Digital Mine... 6 3. Main co ntrol fun ction s of th e Digital
R. Ruckman & B. Prosser Mine Ventilation Services, Inc., Clovis, California USA
13 th United States/North American Mine Ventilation Symposium, 2010 Hardcastle & McKinnon (Eds.) 2010, MIRARCO - Mining Innovation Integrating ventilation monitoring sensor data with ventilation computer
The Advantages of Enterprise Historians vs. Relational Databases
GE Intelligent Platforms The Advantages of Enterprise Historians vs. Relational Databases Comparing Two Approaches for Data Collection and Optimized Process Operations The Advantages of Enterprise Historians
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
Tnet WIRELESS MESH SENSOR NETWORKS
Product Line Overview Tnet WIRELESS MESH SENSOR NETWORKS The fusion of advanced sensor and actuator technology with state of the art wireless networks has enabled a whole new level of applications for
WIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
Power & Environmental Monitoring
Data Centre Monitoring Made Easy Power & Environmental Monitoring Features & Benefits Packet Power provides the easiest, most cost effective way to capture detailed power and temperature information for
Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level
Solutions for the Process Industries Rosemount Analytical s -STREAM E Web-Browser Interface Takes Process Analysis to the Next Level The -Stream E takes process gas analysis to the level of ease of use
Combined Cycle Control Overview
Combined Cycle Control Overview Introduction The Combined Cycle (CC) solution provides for the control and monitoring of a typical CC power plant in a cost effective, preengineered package. Basic Architecture
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
WATCHMAN Reliability Services Enhance OEM Service Center Revenue
WATCHMAN Reliability Services Enhance OEM Service Center Revenue Keywords: WATCHMAN Analysis, WATCHMAN Remote, Vibration Analysis Services, Online Monitoring, Vibration Analysts, Remote Monitoring, Predictive
Data Management. Graph of Wind Speed distribution, Power Curve and production
Data Management FOR WIND ENERGY DATA ÖRN SMÁRI // GRAFÍSK HÖNNUN // DE Trend lines Graph of Wind Speed distribution, Power Curve and production Wind Rose What is Vista Data Vision VDV is a comprehensive
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)
Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System) Aye Min Zaw 1, Hla Myo Tun 2 Department of Electronic Engineering, Mandalay Technological
Implementing a tracking and ventilation control system at Barrick Goldstrike s underground division
12th U.S./North American Mine Ventilation Symposium 2008 Wallace (ed) ISBN 978-0-615-20009-5 Implementing a tracking and ventilation control system at Barrick Goldstrike s underground division M.A. Meyer
Energy Storage System Performance Testing
Energy Storage System Performance Testing Peter Blume President Bloomy Windsor, CT Abstract This paper describes the energy storage system data acquisition and control (ESS DAC) system used for testing
How To Use Safety System Software (S3)
SPECIFICATION DATA Safety System Software (S3) APPLICATION Safety System Software (S 3 ) is a robust, full featured configuration, diagnostic, programming and real-time monitoring package for integrators
KPI, OEE AND DOWNTIME ANALYTICS. An ICONICS Whitepaper
2010 KPI, OEE AND DOWNTIME ANALYTICS An ICONICS Whitepaper CONTENTS 1 ABOUT THIS DOCUMENT 1 1.1 SCOPE OF THE DOCUMENT... 1 2 INTRODUCTION 2 2.1 ICONICS TOOLS PROVIDE DOWNTIME ANALYTICS... 2 3 DETERMINING
A Proposed Integration of Hierarchical Mobile IP based Networks in SCADA Systems
, pp. 49-56 http://dx.doi.org/10.14257/ijsh.2013.7.5.05 A Proposed Integration of Hierarchical Mobile IP based Networks in SCADA Systems Minkyu Choi 1 and Ronnie D. Caytiles 2 1 Security Engineering Research
Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy
Data Center Solutions Packet Power for Data Centers Packet Power provides the easiest, most cost-effective way to capture detailed power and temperature information for both single-site and large multi-facility
OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:
Filed: September 0, 00 EB-00-0 Tab Schedule Page of OPERATIONS CAPITAL.0 INTRODUCTION Operations Capital funds enhancements and replacements to the facilities required to operate the Hydro One Transmission
Best Practices for Wire-free Environmental Monitoring in the Data Center
White Paper 11800 Ridge Parkway Broomfiled, CO 80021 1-800-638-2638 http://www.42u.com [email protected] Best Practices for Wire-free Environmental Monitoring in the Data Center Introduction Monitoring for
LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring
LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions
Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities
Linear Heat Series Fiber Optic Linear Heat Detection System Tunnels & Metros Conveyer Belts Parking Lots Manufacturing Warehouse Facilities Refineries and Power Plants Intelligent Solutions Are you looking
Movicon in energy efficiency management: the ISO 50001 standard
Movicon in energy efficiency management: the ISO 50001 standard The importance of energy consumption within the company reflects the importance of the world energy crisis due to a growing demand and the
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
WISE-4000 Series. WISE IoT Wireless I/O Modules
WISE-4000 Series WISE IoT Wireless I/O Modules Bring Everything into World of the IoT WISE IoT Ethernet I/O Architecture Public Cloud App Big Data New WISE DNA Data Center Smart Configure File-based Cloud
Introduction. Background
Predictive Operational Analytics (POA): Customized Solutions for Improving Efficiency and Productivity for Manufacturers using a Predictive Analytics Approach Introduction Preserving assets and improving
Remote Monitoring and Satellite Communications
Mining, Oil & Gas: Abstract With the majority of Australia s mineral, oil and gas reserves situated in remote locations, resource companies can struggle to get timely access to the data they need to make
Infinity 2020 Perimeter Intrusion Detection System
Infinity 2020 Perimeter Intrusion Detection System User Guide: Network Application Your First Line of Defense 1 Infinity 2020 Perimeter Intrusion Detection System Table of Contents Section 1: Getting Started...
Power Quality For The Digital Age INVERTING SOLAR POWER A N E N V IRONME N TA L P OT E N T I A L S W HI T E PA PER. www.ep2000.com 800.500.
Power Quality For The Digital Age INVERTING SOLAR POWER A N E N V IRONME N TA L P OT E N T I A L S W HI T E PA PER Introduction Heat in the System The modern facility has been revolutionized by advancements
DATA LOGGING FOR TECHNICAL SERVICES AT CERN
DATA LOGGING FOR TECHNICAL SERVICES AT CERN R. Martini, H. Laeger, P. Ninin, E. Pfirsch and P. Sollander CERN, Geneva, Switzerland Abstract A data-logging system for the technical infrastructure of CERN
Catalyst RTU Controller Study Report
Catalyst RTU Controller Study Report Sacramento Municipal Utility District December 15, 2014 Prepared by: Daniel J. Chapmand, ADM and Bruce Baccei, SMUD Project # ET13SMUD1037 The information in this report
PLCs and SCADA Systems
Hands-On Programmable Logic Controllers and Supervisory Control / Data Acquisition Course Description This extensive course covers the essentials of SCADA and PLC systems, which are often used in close
Practical Application of Industrial Fiber Optic Sensing Systems
Practical Application of Industrial Fiber Optic Sensing Systems John W. Berthold and David B. Needham Davidson Instruments, Inc. P.O. Box 130100, The Woodlands, TX 77393 ABSTRACT In this presentation,
Big Data Collection and Utilization for Operational Support of Smarter Social Infrastructure
Hitachi Review Vol. 63 (2014), No. 1 18 Big Data Collection and Utilization for Operational Support of Smarter Social Infrastructure Kazuaki Iwamura Hideki Tonooka Yoshihiro Mizuno Yuichi Mashita OVERVIEW:
CATALYST Frequently Asked Questions
CATALYST Frequently Asked Questions Q: What is the CATALYST Efficiency Enhancing Controller (EEC)? A: The CATALYST is a retrofit technology for single-zone, constant-volume, roof top packaged HVAC systems.
BROWSER-BASED HOME MONITOR USING ZIGBEE SENSORS
Review of the Air Force Academy No 2 (24) 2013 BROWSER-BASED HOME MONITOR USING ZIGBEE SENSORS Marian ALEXANDRU, Vlad URSU Transilvania University of Brasov, Romania Abstract: A study of how to implement
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
Cat Detect. for Surface Mining Applications
Cat Detect for Surface Mining Applications Enhance Your Site s Safety through Increased Operator Awareness Configurable to suit your operation s needs, Cat MineStar System is the industry s broadest suite
Intelligent Vibration Monitoring
Diagnostic Systems Condition Based Monitoring Diagnostic Systems Condition Based Monitoring Intelligent Vibration Monitoring efector Octavis for real-time vibration monitoring Solutions for Predictive
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution
System integration oriented data center planning In terms of ATEN's eco Sensors DCIM solution 1. Introduction The reliability of an enterprise data center servicing either external or internal clients
Android based Alcohol detection system using Bluetooth technology
For more Project details visit: http://www.projectsof8051.com/android-based-alcohol-detection-system-usingbluetooth-technology/ Code 1435 Project Title Android based Alcohol detection system using Bluetooth
On-Site Risk Management Audit Checklist for Program Level 3 Process
On-Site Risk Management Audit Checklist for Program Level 3 Process Auditor name: Date: I. Facility Information: Facility name: Facility location: County: Contact name: RMP Facility I.D. Phone Number:
Real-time Monitoring Platform to Improve the Drinking Water Network Efficiency
Real-time Monitoring Platform to Improve the Drinking Water Network Efficiency SUMMARY Recent advances in real-time water sensing technology have enabled new opportunities for improved assessment and management
The data can be transmitted through a variety of different communications platforms such as:
COMMUNICATION NETWORK General Overview of SCADA Communications Without a properly designed communication network system, a SCADA system cannot exist. All supervisory control and data acquisition aspects
How To Run A Data Center Efficiently
A White Paper from the Experts in Business-Critical Continuity TM Data Center Cooling Assessments What They Can Do for You Executive Summary Managing data centers and IT facilities is becoming increasingly
Technical Training Module ( 30 Days)
Annexure - I Technical Training Module ( 30 Days) Section 1 : Programmable Logic Controller (PLC) 1. Introduction to Programmable Logic Controller - A Brief History, Need and advantages of PLC, PLC configuration,
How To Use Vista Data Vision
Data Management SOFTWARE FOR -meteorological Data -Hydrological Data -Environmental data ÖRN SMÁRI // GRAFÍSK HÖNNUN // DE Trend lines What is Vista Data Vision VDV is a comprehensive data management system
Hazard Identification and Risk Assessment for the Use of Booster Fans in Underground Coal Mines
Hazard Identification and Risk Assessment for the Use of Booster Fans in Underground Coal Mines Felipe Calizaya Michael G. Nelson Mahesh Shriwas Feb 26, 2013 Outline Introduction Booster Fans in U/G Coal
MDS. Measured Data Server Online Measurement Network. Properties and Benefits »»» »»»» ProduCt information
ProduCt information MDS Measured Data Server Online Measurement Network Properties and Benefits Unlimited access to your data via Internet Measured data can be transferred online in minute intervals Economical
Energy efficient Smart home based on Wireless Sensor Network using LabVIEW
American Journal of Engineering Research (AJER) e-issn : 2320-0847 p-issn : 2320-0936 Volume-02, Issue-12, pp-409-413 www.ajer.org Research Paper Open Access Energy efficient Smart home based on Wireless
Trace Gas Exchange Measurements with Standard Infrared Analyzers
Practical Environmental Measurement Methods Trace Gas Exchange Measurements with Standard Infrared Analyzers Last change of document: February 23, 2007 Supervisor: Charles Robert Room no: S 4381 ph: 4352
Classification of Data Center Operations Technology (OT) Management Tools
Classification of Data Center Operations Technology (OT) Management Tools White Paper 104 Revision 0 by Kevin Brown Dennis Bouley > Executive summary Data centers today lack a formal system for classifying
STERIDRY DRY HEAT Sterilization. Lower Cost, Worry-Free & Green WHY GRUENBERG DRY HEAT STERILIZATION?
WHY GRUENBERG DRY HEAT STERILIZATION? Design assistance from leader in lab animal science sterilization Lowest total cost of ownership Greater output in a smaller footprint Safer operation Extended cage
Semaphore T BOX Applications in Data Center Facilities
Semaphore T BOX Applications in Data Center Facilities Introduction Data centers must reliably provide 24/7/365 operation. For automation and monitoring of the facility, use of a rugged, reliable RTU is
HELIUM PULSE FOR MONITORING AND ALERTING HELIUM SMART SENSORS HELIUM NETWORK HELIUM CLOUD HELIUM PULSE HP20160414-01
HELIUM PULSE FOR MONITORING AND ALERTING Helium Pulse enables organizations to make sense of their things; to easily and cost-effectively monitor their assets and the environment to maximize performance
Communication Packages: Manual Method
Communication Packages: Manual Method Diver USB Reading Unit Handheld connection PC connection Connect your PC, Laptop, or Pocket-PC to a Diver with the Reading Unit to: - Download data - Program settings
Smart. Scalable. Simple.
Thermo Scientific Wireless Monitoring Solution Smart. Scalable. Simple. providing the protection you need with the simplicity you deserve Thermo Scientific Wireless Monitoring Solution Optimized Sample
Facility Monitoring Services for More Efficient Maintenance of Social Infrastructure
259 Hitachi Review Vol. 63 (2014), No. 5 Featured Articles Facility Services for More Efficient Maintenance of Social Infrastructure Masaki Ogihara Masafumi Uematsu Daisuke Shibata Sachio Minami OVERVIEW:
Social Innovation through Utilization of Big Data
Social Innovation through Utilization of Big Data Hitachi Review Vol. 62 (2013), No. 7 384 Shuntaro Hitomi Keiro Muro OVERVIEW: The analysis and utilization of large amounts of actual operational data
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
S300 Series Dust Monitors
S301 DustGuard S303 Trend Monitor S304 Emission Monitor S305 Stack Monitor Intrinsically Safe (ATEX) Dust Monitors Split Architecture (Remote)Models Data Logging Software S300 Series Dust Monitors Dust
Thermal Monitoring Best Practices Benefits gained through proper deployment and utilizing sensors that work with evolving monitoring systems
NER Data Corporation White Paper Thermal Monitoring Best Practices Benefits gained through proper deployment and utilizing sensors that work with evolving monitoring systems Introduction Data centers are
How To Design A Gas Dryer
Non Domestic Laundry Gas Appliance Installation Code of Practice Introduction This code of practice has been produced with the assistance of all Companies within the OPL sector of SLEAT because of the
SCADA and Monitoring for Solar Energy Plant
SCADA and Monitoring for Solar Energy Plant Segment: Industry Country: Thailand Author: Ranon Satitpanyapan Products: NI LabVIEW with LabVIEW Real-Time Module crio Real-Time controller 8 slot with 16 current
NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER
NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER Understanding what a PAC is starts from the understanding of PLC. A PLC is a Programmable Logic while
Wireless Communications for SCADA Systems Utilizing Mobile Nodes
, pp. 1-8 http://dx.doi.org/10.14257/ijsh.2013.7.5.01 Wireless Communications for SCADA Systems Utilizing Mobile Nodes Minkyu Choi Security Engineering Research Support Center, Daejon, Republic of Korea
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
A DNP3 Protocol Primer
A Protocol Primer Introduction This is a primer for people who want a quick understanding of without having to comb through the tedious details of a complex specification. The writing style is meant to
Mineral Insulated Cable A cable for today and tomorrow!
Mineral Insulated Cable A cable for today and tomorrow! Bill Davis Technical and Business Development Director If MIC had never been introduced, the industry would be actively pursuing the development
FACILITY AND VENUE PROTECTION
FACILITY AND VENUE PROTECTION INTRODUCTION In late 2001, the Department of Homeland Security was created to develop and coordinate the implementation of a comprehensive national strategy to secure the
Process Control and Automation using Modbus Protocol
Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has
COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal
Version: Optic COMPLETE MANUAL September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal Specifications are subject to change without notice.
CHAPTER 12 MONITORING AND CONTROL SYSTEMS
CHAPTER 12 MONITORING AND CONTROL SYSTEMS To manage onsite wastewater treatment systems properly, monitoring of process operation and performance is necessary. Because of the increasing number and complexity
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010 1. Background Class II Type B Biosafety Cabinets (BSCs) are unique laboratory
Temperature Alert. LAN-based Temperature and Humidity Data Logger
Temperature Alert LAN-based Temperature and Humidity Data Logger LAN-based Temperature and Humidity Monitoring - Supports Simultaneous WiFi and Hardwired Interfaces -20 C to +60 C (-4 F to +140 F) Standard
Revolutionizing Data Center Infrastructure Management
Infrastructure Management & Monitoring for Business-Critical Continuity TM Revolutionizing Data Center Infrastructure Management The Trellis Platform A Real-Time Solution to Continuous Performance Improvement
Kurz Instruments Inc. Document 360209-AV Document Title: MFTB Event Code Definitions. MFT B-Series Event Codes
MFT B-Series Event Codes The MFT B-series status information is contained in a 4-byte long word (32-bit) Event Code. This Event Code provides a bit-wise mapping of the status of the flow meter with each
Monitoring & Control of Small-scale Renewable Energy Sources
Small Scale Renewable Energy Sources and Energy Saving: 6-17 th July 2009 Monitoring & Control of Small-scale Renewable Energy Sources Dr G A Taylor Brunel Institute of Power Systems Brunel University,
Particle Monitoring Requirements in Pharmaceutical Cleanrooms
Particle Monitoring Requirements in Pharmaceutical Cleanrooms All drugs must be manufactured in accordance with the current Good Manufacturing Practice (cgmp) regulations. Pharmaceutical manufacturers
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
Underground Mine Rescue Equipment and Technology
Underground Mine Rescue Equipment and Technology REFERENCE #: RIN 1219-AB44 Prepared for: Mine Safety and Health Administration Date: 24 March 2006 Submitted by: Savi Technology, Inc. 3601 Eisenhower Ave.,
C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning
C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning Document Number: CBUS-APP/25 Comments on this document should be addressed to: Engineering Manager Clipsal Integrated Systems PO Box 103
Gallagher Vapour Recovery Monitoring
Gallagher Vapour Recovery Monitoring VR Site Monitoring The status display enables site operators to comply with VR legislation. The laws and guidelines for the New South Wales Vapour Recovery regulations
The Advantages of Plant-wide Historians vs. Relational Databases
GE Intelligent Platforms The Advantages of Plant-wide Historians vs. Relational Databases Comparing Two Approaches for Data Collection and Optimized Process Operations The Advantages of Plant-wide Historians
GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide
GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide GlobalSat WorldCom Corporation 16F., No. 186, Jian 1 st Rd, Zhonghe Dist., New Taipei City 23553, Taiwan Tel: 886.2.8226.3799/ Fax: 886.2.8226.3899
DUST EMISSION MONITORING SYSTEM
Applications Measurement of dust concentration in dry or moist, steamsaturated and corrosive stack gases Monitoring of municipal and hazardous waste and sewage sludge incinerators Monitoring of power plants