Appendix A: SOP of Information Required from Tyson and Information for the Producer
|
|
|
- Meagan McDaniel
- 9 years ago
- Views:
Transcription
1 Appendix A Page 1 of 1 Appendix A: SOP of Information Required from Tyson and Information for the Producer Measurements To Be Taken 1. Inside and outside temperature and relative humidity. 2. Fan status (on/off) and airflow rate. 3. Operation of lights, feeders. 4. Static pressure difference between inside and outside the barn. 5. Inside and outside ammonia and carbon dioxide concentrations. Measurement Duration Continuous monitoring of two barns for 12 months, beginning January Measurement Logistics Gas samples are collected using flexible FEP tubes, at three locations in each barn. All gas samples and instrumentation equipment are housed in an 8 ft 14 ft MAEMU positioned adjacent to the barn. This MAEMU will serve as a shelter for measurement instrumentation. Project staff visit the site once a week or more often as needed. This is required to check equipment status, calibrate sensors, and to make sure everything is working as planned. Most of this time is spent in the instrumentation trailer and not the barns, although some time needs to be spent in the barns to change sample line filters, TEOM filters, exchange TEOM inlet heads, and to check sensors. Strict adherence to biosecurity as per Section 10 will be followed. Barn Modifications In order to introduce the sensor wires and gas sampling lines into the barns, two 4-in PVC pipes connect the MAEMU to each barn. These pipes house data lines and air sample lines and are buried. Requirements for Tyson and Collaborating Producer Tyson is required to provide the university the following information about each barn: 1. Animal diet, feed consumption, inventory and body weight 2. Production outputs, marketed birds and birds mortality 3. Record of litter removals 4. Record of cleaning operations 5. Record of animal movements in and out of the barn 6. Record of water consumption 7. Advance notification of any alteration in production schedules and methods. 8. Record of equipment failures, (e.g., ventilation fans, inlet control) 9. Power failures 10. Temperature set points 11. Operation of lights 136
2 Appendix B Page 1 of 3 Appendix B: SOP of Gas Sampling System Vacuum pumps (P1-P4) with Teflon wetted parts are used to deliver air from the sampling locations via solenoids and a manifold (M1) and transport the air stream to another manifold (M2) connected to the gas analyzer. Teflon or Teflon coating is used in all wetted parts of the sampling system (pump, solenoid valves, manifold, and tubing). Four pairs of 2-way solenoid valves (S1-S8) located in sampling lines are controlled by the DAQ system and control unit to allow measurements of gas concentrations by automatic gas sampling from four locations (Figure B.1). To avoid the malfunction of solenoid valves as a result of overheating, solenoid cool boards are used to drive the solenoid valves. When the control module sends the signal to the cool boards, the cool boards will provide full power (12 VDC) on the solenoids during the first 100 ms and then cut the power to approximately half (5 VDC) and hold it. The cool boards solve the overheating problem of the solenoid valves (Figure B.2). Individual supply pumps with 16 L/min delivering capacity are used to continuously draw air from each of the sampling locations. The sampling train is designed such that a sample will be drawn from all four sampling points continuously unless a sampling point is not being analyzed. When this occurs, the flow will be bypassed through the normally open solenoid valve (S5-S8). This arrangement is designed to minimize the residence time and thus greatly reduce sample-to-sample purging time. When a sampling stream is selected, the corresponding normal close valve will open and the normal open valve will close; and the selected gas stream will flow from the sample inlet via the tubing through the manifolds (M1 and M2). The internal pump of the gas analyzers draws air from manifold M2. The gas sampling system is designed such that all solenoid valves, manifolds, and associated connections are under positive pressure. Using this positive pressure approach, if a leak were to develop on the gas sampling control board at any of these components it would not impact the integrity of the gas sample. Exhaust Ambient air P 4 S8 S4 INNOVA 1412 Location 1 P 3 S7 S3 API 101E VIG 200 Location 2 Location 3 P 2 P 1 S6 S2 S5 S1 M1 M2 Exhaust Flow meter Filter P: Pump M: Manifold S: Solenoid Filter S1-4:Normal Close S5-8:Normal Open Compact Fieldpoint DAQ Figure B.1. Schematic of sampling system configuration. (The analyzers have internal pumps.) 137
3 Appendix B Page 2 of 3 When needed, sampling lines are heated with heat trace or heat tape to prevent in-line condensation. Temperature of the sampling line, and thus power input of the heat trace or tape, is continuously monitored and regulated through the DAQ and control system. Solenoid Cool Board Power Plug 12 VDC power supply 5 VDC power supply 24 VDC power supply Compact FieldPoint Power supply Compact FieldPoint Control module Figure B.2. Electronic board and control modules for the sampling system. Two pleated paper filters are used to exclude insects and other coarse particulates. Additionally, a 47-mm diameter, in-line Teflon PFA filter holder housing a Teflon PTFE-laminated polypropylene membrane filter with 20-μm pore size is installed at the sampling end of each gas sampling tube to remove airborne particulate from the sampled air. Another 5-μm pore size PTFE filter is installed right after the vacuum pump to provide double protection. Both in-house sample filters are changed weekly (Figure B.3). 138
4 Appendix B Page 3 of 3 Figure B.3. Photographs of the air sampling system. 139
5 Appendix C Page 1 of 4 Appendix C: SOP of Field Estimation of Ventilation Capacity Using FANS Field Estimation of Ventilation Capacity Using UK Version 1 FANS Unit Introduction A device for in-situ exhaust fan airflow capacity measurement, referred to as the Fan Assessment Numeration System (FANS) device, previously developed and constructed at the USDA-ARS Poultry Research Unit, was refined and constructed by University of Kentucky (Gates et al., ). FANS measures the total airflow rate of a ventilation fan by integrating the velocity field obtained from an array of five propeller anemometers used to perform a real-time traverse of the airflow entering ventilation fans of up to 122-cm (48-in) diameter. This SOP provides instructions on installation of the program and operation of the FANS analyzer, and helps in producing high quality measurements. Data Acquisition Computer Before using the FANS analyzer, it is necessary to prepare a computer with the required hardware and software to link with the FANS analyzer to control and record data. For this, a Keithley DriverLINX card, and the WildCat Anemometer Program (Anemometer2.exe) is needed. The installation procedures that follow were provided by Ken Casey of the University of Kentucky and distributed with each FANS unit manufactured. Installing Keithley DriverLINX and Anemometer Program 1. Close down all background applications of the computer to be installed 2. Insert Keithley Card into PCMCIA 3. Insert the Keithley DriverLINX CD and run the autostart program with command setup.exe 4. After the installation window appears, click Install DriverLINX 5. Click Install Drivers c:\program Files\DrvLINX4 6. and follow directions for registration, use defaults 7. Click Install Interfaces same procedures as step a 8. Be sure to select all options (three of them) 9. Use default folder 10. Click Install Documentation use default folder 11. Click Back, Exit, and Done 12. Your computer will be restarted 1 Gates, R. S., K. D. Casey, H. Xin, E. F. Wheeler, J. D. Simmons Fan Assessment Numeration System (FANS) design and calibration specifications. Transactions of the ASAE 47(5):
6 Appendix C Page 2 of Once restarted, a screen should come up for hardware configuration 14. Follow step 2. Plug & Play should install drivers 15. Wait some time for response 16. Afterwards click continue, follow directions 17. Probably, click configure 18. Under hardware configuration 19. Assign logical device number (the default probably 0) 20. Leave all other values at default, click OK, and close window 21. Remove Keithley Card, wait about 10 seconds 22. Reinsert card, click Start, Programs, DriverLINX, Test Panels 23. Run the AIO Panel 24. If it says No Driver loaded reboot, ignore the rest of installer and restart AIO Panel. 25. You should be ready to run 26. You may need to tweak in DriverLINX Configuration Panel 27. Copy Anememeter2.exe and Anememeter2.mdb from floppy disc supplied into your directory FANS Analyzer Unit In order to ensure the FANS analyzer is operating properly, test both manual and software control as follows: 1. Supply the FANS analyzer with power. 2. The right-most toggle switch should be in up position. 3. Toggle left-most switch up and down, holding for a few seconds at a time to ensure that the motor is moving the anemometers properly. 4. After successful manual operation, test the motor up and motor down functions on the computer screen to determine if software has functional control. If all is working properly, initiate a data collection traverse with no airflow and without anemometer propellers installed to establish the zero offset airflow correction. Then place the individual propellers onto the unit. The propellers cannot be installed at the traverse end positions because of limited space; therefore the traverse bar must be moved at least six inches from the top or bottom. Make sure that the number of the propeller and of the open-vane anemometer match (there are five in all numbers are marked on both). Operation The fan to be tested should be turned on and warmed up for at least 10 minutes. A fan is tested over the normal operating range of building static pressure (SP) difference. At least four SPs are tested covering a range from slightly below to slightly above the normal building operating range. After the FANS is positioned at a chosen fan, a static pressure (SP) is set. Once SP has stabilized, two FANS traverses are run in quick succession. If the two runs differ by more than 2%, another traverse is performed. For lower range airflows, a 3% difference between traverses is acceptable. All tests are done when the house has no birds present so that any ventilation condition could be evaluated without jeopardizing bird comfort and well-being. 141
7 Appendix C Page 3 of 4 Moving and Positioning A cart is helpful to aid in moving the FANS unit down the length of a long poultry house and positioning it in front of a fan. A hydraulic lift can be added to provide easy height adjustment of the 80-pound FANS unit to match the test fan height. Moving and positioning is best done with two workers. Complications with FANS setup include the need to move knee braces, water lines and electrical outlets in certain facilities. Each of these situations and other anomalies require special attention and can add substantial time to each setup. Sealing FANS to Fan Housing Sealing the FANS to the wall and/or fan housing is critical to accurate measurement, and can take the bulk of the setup time in moving the FANS from one fan to the next. A special gasket created from open-cell pipe insulation placed over ½-in PVC pipe and positioned between the FANS frame and the wall has been successfully used to provide a tight seal and reduce the need for extensive taping. The FANS is positioned against this gasket and two ratchet straps are used to draw the FANS unit tightly against the gasket and wall. Duct tape is used to seal any remaining gaps or cracks. Fan housings that project through the wall into the interior space can prevent the FANS unit from being placed against the wall and thus present special challenges. For these situations, a 6-inch extension of the FANS frame, constructed of polystyrene and the same dimensions as the FANS frame, has been used to seal against the above mentioned pipe insulation gasket. Duct Transition to Smaller Fan Measurement accuracy is not affected by use of a transition to measure smaller diameter fans. A lightweight collapsible duct (blue polystyrene R-3) can be used to connect the FANS unit, with square opening of about 52 in, to 36 in or smaller fans. Gaps are sealed with duct tape. The duct is 48 inches long, which is about 1.3 fan diameters of the smaller fan, with one to two diameters length considered acceptable. Setup time for the duct is even longer than for the sealing method descried in the previous section for testing larger fans. Wherever possible, the FANS unit should be used directly without a transition, simply to save time. Measuring Larger Ventilation Fans Measurement accuracy is affected by use of a transition to measure larger diameter fans. Available literature (Gates et al., 2004) suggests that there is a penalty associated with forcing airflow through the FANS unit and into a fan whose approach aperture exceeds that of the FANS. It is recommended that each model of fan be independently tested in a certified fan test facility, with and without the FANS unit, to assess the degree of penalty. Ventilation fans of 48 inches or smaller have not been shown to be affected by this issue. Streamlining Data Collection Once the crew is practiced at setting up and operating the FANS at different static pressures, a complete setup and test for 4 or 5 static pressures can be accomplished in 1 to 1 ½ hours per fan in a broiler barn. The approximate time required for each fan test is as follows. About 7 minutes is needed for two consecutive FANS traverses plus data notation time, although more than 2 traverses are sometimes required. Changing and stabilizing each static pressure setting requires 142
8 Appendix C Page 4 of 4 less than 5 minutes, but with even minor complications this can exceed ten minutes. For example, end doors and all inlets need to be opened to get a zero SP reading and then closed again to get the other SP settings. These FANS traverses are preceded by 10 to 20 minutes of FANS positioning and about 10 minutes of sealing the FANS to the fan housing. If a transition duct is used for a 36-inch fan, then 40 to 50 minutes is needed to assemble and seal a pre-cut duct between the FANS and the fan housing. More time is needed if the duct is fabricated from scratch. Walkie-talkie radios are used so that the person adjusting static pressure in the control room can communicate with the person(s) running the FANS unit. Often these two people are out of sight of each other. The radios eliminate disruptive yelling and miscommunications. The FANS unit operator can tell the SP control person when tests are completed. Likewise, the SP control person can indicate when the test SP is adjusted and steady in order to start the test. 143
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
Standard Hydraulic Piping Flushing Procedure
Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
Overheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
How To Use A Corona Mdi 110
CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output
STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010 1. Background Class II Type B Biosafety Cabinets (BSCs) are unique laboratory
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
Small Animal Respiratory Exchange Ratio (RER)
iworx Physiology Lab Experiment Experiment AMe-1 Small Animal Respiratory Exchange Ratio (RER) Note: The lab presented here is intended for evaluation purposes only. iworx users should refer to the User
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms
Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Agenda Review of cooling challenge and strategies Solutions to deal with wiring closet cooling Opportunity and value Power
G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Energy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
WAVELET WATER QUALITY MONITORING KIT
AYYEKA Rethink Water Monitoring WAVELET WATER QUALITY MONITORING KIT ON OFF QUICK START GUIDE AYYEKA IMPORTANT! Use with pressure applications up to 145 PSI. Contact AYYEKA SUPPORT center for technical
Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...
Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system
Thermo Top - Troubleshooting Tree
Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may
Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier
Help Help Software Tutorial Building a load sizing project with an ME Series Humidifier 502-B 18 Aug 2015 Help Tutorials provide step-by-step examples of complete load sizing projects and browser projects
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
Whitepaper Modular Integration of Process Equipment Packages for Oil and Gas Facilities
Whitepaper Modular Integration of Process Equipment Packages for Oil and Gas Facilities Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Abstract An integrated design approach to a modular
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters M-4270/0707, pg. 2 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Managing Heat Stress in Poultry
Managing Heat Stress in Poultry Amy E. Halls, Monogastric Nutritionist Shur-Gain, Nutreco Canada Inc. Heat stress has several serious and economical effects on poultry. In broilers and turkeys, it can
CE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...
Energy Efficiency. Bars & RestauRants. www.energia.ie
Energy Efficiency Bars & RestauRants www.energia.ie 2 Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
Control Box Wiring For PRSstandard Tool
888-680-4466 ShopBotTools.com Control Box Wiring For PRSstandard Tool Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Table of Contents Introduction:...5 Installation:...5
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
Experiment HE-6: Breath by Breath Measurement of Respiratory Exchange Ratio (RER)
Experiment HE-6: Breath by Breath Measurement of Respiratory Exchange Ratio (RER) Background The two sources of energy available for human metabolism are carbohydrates (CHO) and fats. These molecules are
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
Quanser NI-ELVIS Trainer (QNET) Series: QNET HVAC. Heating, Ventilation, and Air Conditioning (HVAC) User Manual. User Manual
Quanser NI-ELVIS Trainer (QNET) Series: QNET HVAC Heating, Ventilation, and Air Conditioning (HVAC) User Manual User Manual Table of Contents 1. Introduction...1 2. Requirements...1 3. References...1 4.
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
SALEEN SPEEDLAB SERIES VI STANDARD SC UPGRADE KIT
SALEEN SPEEDLAB SERIES VI STANDARD SC UPGRADE KIT INSTALLATION MANUAL: 2005 MUSTANG 4.6 3V MANUAL P/N: 10-8002-C14338C SUPERCHARGER KIT P/N: 10-1607-B14083* Saleen Performance, Inc. 1225 East Maple Rd.,
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP
research journal 2013 / VOL 05.01 www.perkinswill.com SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP ARCHITECTURE AND ENGINEERING OF SUSTAINABLE BUILDINGS Current Trends in Low-Energy HVAC Design
DESIGN STANDARDS SECTION 23 60 00
PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.
A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
Turbocharger system components, servicing
21-1 Turbocharger system components, servicing Engine codes: AAZ, 1Z, AHU Observe rules of cleanliness Page 21-10 Turbocharger hoses and lines, connecting Page 21-11 WARNING! Do not re-use any fasteners
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
Air Conditioning Sign-Off Sheet
Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
NSN 4120-01-21 4-3692
*TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21
1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Healthcare Solutions Room Pressure Monitors and Controls
Healthcare Solutions s and Controls TOUCHSCREEN ROOM PRESSURE MONITOR The Touchscreen Room Pressure Monitor (PMT) provides precise room pressure monitoring for critical spaces such as isolation rooms,
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
Zehnder Focus 200. Ventilation device
Ventilation device Use The Zehnder Focus (F) 200 comfort ventilation unit was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation
Gas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat
Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat MOUNTING LOCATIONS Refer to the guidelines below and Fig. 1 5 for mounting locations of the Discharge and Return Air Temperature Sensors.
AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002
AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002 First Edition MONITORING AND LABORATORY DIVISION August
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters
Designed for multi-injector endurance testing, the
Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures
DOE-HDBK-1122-99. Module 2.18 Air Sampling Equipment. Instructor s Guide
Course Title: Radiological Control Technician Module Title: Air Sampling Equipment Module Number: 2.18 Objectives: 2.18.01 Identify the factors that affect the operator's selection of a portable air sampler.
Installing a Probe. Typical Installation
for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assembly
VSO MAX HP High Flow Proportional Valve
VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ
TSQ--0 7-7-07 T Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T SQ Model Configuration T SQ- Heating / Cooling Border Type (Lay-In) Full Face Nominal Round Duct Size
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration
UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
Laminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
Test Code: 8297 / Version 1
Blueprint HVAC Maintenance Technology PA Test Code: 8297 / Version 1 Copyright 2014. All Rights Reserved. General Assessment Information HVAC Maintenance Technology PA Blueprint Contents General Assessment
Ammonia Detection System Codes and Design Specifications
Ammonia Detection System Codes and Design Specifications December 28, 2015 Revision 5 920 N Trade Winds Pkwy Columbia, MO 65201 Ammonia detection system codes and design specifications Following is a discussion