MEDICAL CATALOGUE Nordic range
|
|
|
- Polly Nicholson
- 9 years ago
- Views:
Transcription
1 MEDICAL CATALOGUE Nordic range EDITION 2/2012
2 GCE worldwide Sales office Sales representation Headquarters Production units Stock point the GCE Business GCE has almost 100 years of experience in the manufacture and supply of high pressure gas equipment. During this time the GCE product range has increased dramatically. Today s product portfolio fits a large variety of applications, from simple pressure regulators and blowpipes for cutting and welding to highly sophisticated gas supply systems for the medical, electronic and analytical industries. GCE Group includes four business areas: Cutting & Welding Process Application Medical High Purity Origins Sales office Sales representation Headquarters Production units Stock point The origins of GCE (Gas Control Equipment) go back to the start of the 20 th century when Gas Welding was first invented. The GCE group was formed as an independent company in 1987 through the merging of two of the worlds leading gas and welding companies into one independent unit. GCE has grown rapidly since its establishment and is leading the restructuring of the European gas equipment industry through mergers and acquisitions. Through its extensive Research and Development programs GCE has set standards that have become the benchmark for the whole industry. GCE services The main industrial customers for GCE are wholesalers and local distributors. However in some markets GCE distributes equipment with the full cooperation of the main gas supplier for that market. For these companies GCE provides both commercial and technical support. A significant part of the sales volume in this area also comes from key end user accounts such as shipyards, repair shops, OEM customers and welding machine manufacturers. A COMPLETE RANGE FOR MEDICAL The supply of Medical Gas Equipment is a very important part of our business. All Medical Gas Applications require the highest safety standards, specialised knowledge and a full understanding of patient respiratory requirements. GCE fully complies with the European Medical Directive 93/42/EEG and the QSR (Quality System Regulations known as the GMP standards). Western Europe is the traditional market for a whole range of products for all different types of customers and together with the growing Eastern European market, these are GCE s main sales area. Our sales force is also active in a number of other markets including North and South America, North Africa and the Middle East, and continues to expand to other parts of the world, such as China and India. As a result, our products are designed in accordance with the requirements of all European standards as well as those of other regions where they will be used. Supplies to the major Gas Companies account for the majority of sales however in each market various distributors, healthcare providers, hospitals and other manufacturers of medical also play a significant role in the distribution of GCE-branded and CE-marked products. GCE supply complete systems for supplying oxygen, nitrous oxide, other gases and vacuum to hospitals, ambulance service providers, emergency services and home care providers, as well as other special services using this equipment.
3 Contents Contacts GCE Norden AB 3 Service and Maintenance of Medical Equipment COMBI VALVES - Valves Integrated with Pressure Regulator 5 Combilite High pressure regulators 9 MediSelect II MediReg II Varimed MMR Sabre Select Flow Sabre Resuscitation Regulator Spare Parts hospital ward equipment 21 Vacuum Regulator - Medievac Accessories for Medievac Suction Ejector - Medieject-32/Medieject-33 only DK Accessories - Suction Bottles - with single use bags Accessories - Suction jars - MediCollect Flowmeter - MediMeter Low Pressure Regulator - Mediflow Ultra II Flow Selector - MediFlow II 50 l/min Accessories - MediWet II Humidifier Low Pressure Hoses Low Pressure Hoses - MediConnect Rail Complete (30 10 Nordic), without Screws Multiflex Rail (30 10 Nordic) EU Rail Complete (25 10 EU), without Screws Clamps Trolleys Cylinder Holders Quick Couplers - Male Quick Couplers - Female Double Outlets Accessories Ward HomeCare 41 Pneumatic Gas Server - ELITE Oxygen Conserver - ECOlite Accessories for Gas Saver
4 Emergency Equipment Demand Valves - EASE II Bag Valve Masks Masks Ambulance Gas Panel II Ambulance Regulators - MediReg II with Electronic Signal Gauge Ambulance Regulators - Varimed with Electronic Signal Gauge Gauge with Electrical Output Signal (same for MediReg II and Varimed) GSS Multistar Hospital Central Gas supply system 59 MM90 Automatic Gas Manifold MM90 Semiautomatic Gas Manifold MM90 STANDBY Backup Medical Gas Manifold Gas Manifold MC Gas Manifold MC Collection Pipe Line High Pressure Hoses Stabilizer for Medical Oxygen, N 2 O and Air - MM Stabilizer for Medical Oxygen, N 2 O and Air - MC Simplex MMR Gas Manifold Medical Shut-off Valves Non Return Valve Emergency Shut-Off Valve Box DN Emergency Shut-Off Valve Box DN Pressure Watch with Gauge, Alarm and Quick Coupling DN Pressure Watch with Gauge, Alarm and Quick Coupling DN Pressure Monitor DN Alarm C44 System MC Digital Pressure Monitor Gas Alarm G Gas Outlet MC70 (Terminal Unit) Safety Valve Medical Pipeline Systems Pressure Transmitter Connecting Pipes for Cylinder Manifolds Cylinder Retaining Brackets Connection Pipes for Cylinder Pack Manifolds Extension Pipes Connecting Components for Cylinder Manifolds Non-return Valves for Connection Pipes High Pressure Filter SIMPLEX - DUPLEX High Pressure valves DUPLEX High Pressure valves Gas Signs REGULATORS AND FLOW METERS FOR MEDICAL GASES 86 CERTIFICATES 87 General business terms and conditions 88 2
5 Contacts GCE Norden AB GCE Norden GCE Norden has sales office and a service center in Malmö south of Sweden. We are working with order handling, service & repair, product customisation and product support. GCE Norden serves customers throughout the Nordic and Baltic countries. Our customers include everything from health care centres, home care, laboratories, distributors and manufacturing industries. We are certified according to ISO 9001 and ISO EN and all medical equipment are CE marked and complies with the Medical directive 93/42/EEG. Reykjavik ICELAND GCE Norden sales office Malmö NORWAY SWEDEN FINLAND Helsinki Oslo Tallinn Stockholm ESTONIA Rïga LATVIA ZEMGALE LATGALE DENMARK Copenhagen Malmö LITHUANIA Vilnius Switchboard: + 46 (0) Fax: + 46 (0) Customer service and order Fax: + 46 (0) Customer service manager Olof Hansson Phone: +46 (0) [email protected] Order Monica Brodin Phone: +46 (0) [email protected] Order Suzette Schramm Davholt Phone: +46 (0) [email protected] Sales and Product support Fax: + 46 (0) Sales - Sweden Mikael Kram Phone: +46 (0) [email protected] Sales - Denmark, Norway and Island René Frimodt Phone: +46 (0) [email protected] Product support, Sales Finland and the Baltic countries Gabor Gyllvin Phone: +46 (0) [email protected] SERVICE Fax: + 46 (0) Service and quality Åke Andersson Phone: +46 (0) [email protected] Service Olle Lindblad Phone: +46 (0) [email protected] 3
6 service Service and maintenance of medical equipment Keep control over Economy Function Performance Safety We provide authorized service, inspections, maintenance and audits of products in our range. In the service and maintenance workshop in GCE Norden we provide service and maintenance of medical equipment. The manufacturing of medical equipments is strictly regulated by standards also during the products whole life time. We have Authorization from manufacturer (owner of CE-marking) Service technicians trained for medical products MDD Full quality Assurance System Approval Certificate (annex II of the directive 93/42 EEC on medical devices) Quality approval according to ISO 9001, ISO Medical gas applications needs specialist qualifications. The requirements of safety, cleanness and strictness is very high, as the understanding of patient care and physical therapy of inhale and exhalation. GCE service gives the customer a safe medical product with high quality. We service vacuum regulators, pressure regulators, suction ejectors, flowmeters, flowselectors, humidifyers, hoses manifolds and gasoutlets. The quality requirements are in accordance with medical directive MDD 93/42/EEG in Europe and QSR - Quality System Regulations, more known as GMP. Please contact GCE Norden service department for further information regarding your products. Service technician Åke Andersson Phone: +46 (0) Mobil: +46 (0) [email protected] Service technician Olle Lindblad Phone: +46 (0) Mobil: +46 (0) [email protected] 4
7 COMBI VALVES
8 COMBI VALVES Valves Integrated with Pressure Regulator COMBILITE Available in different variants, they are designed to fulfil the requirements for all types of medical gases in different application areas and cylinder pressures up to 300 bar Available with a protective guard and bed hanger for easier and safer handling by the healthcare personnel and patients. Protective guard fits all type of cylinders up to a max. package weight of 24 kg The optional bed hanger facilitates the handling in hospitals, especially during patient transport Combilite combine the function of high-pressure cylinder valve and medical pressure regulator Gas from the cylinder is first controlled by the shut-off valve and then passes through the pressure regulator and delivered to the patient through the flow outlet or the pressure outlet They are always provided with an internal pressure relief valve to protect the user outlets from over pressure 10 years life time without maintenance (O 2, AIR, O 2 /He) Safety features for patients and healthcare personnel Easy to use and lightweight all in one package system Eliminates the need to make high pressure connections Minimizes the risk of contamination Features for gas companies Full traceability of the entire gas package Reliability on quality and performance Added value to the gas package Internal tube filter for quick filling Filling port Gauge Easy to operate flow control hand-wheel Pressure outlet (quick coupler) Flow outlet ON/OFF valve 6
9 COMBI VALVES - Valves Integrated with Pressure Regulator Combilite Standard features Cylinder valve and pressure regulator in one Brass construction Flow control unit Nickel plated body surface Good grip, easy operated hand-wheel Flow outlet ports (firtree, 360 degree swivel function) Active cylinder pressure gauge with colored safety- and refill zones Filling port with non-return valve Integrated pressure relief valve Individual, traceable serial number stamped into body Particle tube filter in front of pressure regulator Residual pressure valve (keeps 3-5 bar residual pressure in cylinder) Optional features Excess flow valve (limits the flow in case of accident and valve shearing) Safety burst disc Wide range of quick couplers according to customer s national standard Teflon taped cylinder connection Electronic memory chip for easy traceability and cylinder control Dip tube (prevents valve against contamination from cylinder when cylinder turned bottom up) Accessories Filling adaptor Safety guard Bed hanger Technical specifications Available for Medical Oxygen, Medical Air, N 2 O/O 2 and other medical mixed gases ON/OFF high pressure isolation valve Long-life rotating mechanism in the ON/OFF valve Non return valve in the filling port Seat material ZYTEL for 200 bar, PEEK for 300 bar Inlet pressure up to 300 bar (4500 psi) Outlet pressure from 3,6 to 5,5 bar according to EN ISO Flow capacity 60 l/min nominal (at full cylinder pressure) Wide range of flow control discs (0-6 l/min, 0-15 l/min, 0-25 l/min) Flow settings 12 steps (including ZERO position) Safety gauge 40 mm Indication range 180 Weight 950 gram* Height 123 mm (measured from the cylinder neck) Outside diameter 115 mm Inlet Stem tapered or parallel threads 17E, 25E (instead of E14 and E25) Filling port ISO 5145, NEVOC or per customer specification Guard two-sided, non protruding handle fits to the valve, not cylinder designed for use on cylinders up to a max package weight of 24 kg drop tested according to EN ISO * Standard Combilite (flow control unit 0-15 l/min, flow outlet, AFNOR quick coupling pressure outlet) without guard. All technical data are given for information only and are subject to modifications by the manufacturer. 7
10
11 HIGH PRESSURE REGULATORS
12 High Pressure Regulator MEDISELECT II The new generation of medical high pressure gas regulators Regulator with flow selector Rotating pressure gauge which allows convenient reading 360 swivelling outlet it enables better orientation of the nasal cannula or oxygen mask towards the patient (preventing from twisting) Innovative self centering flow setting device with continuous flow between settings. In the unlikely event of indent mechanism failure, the patient will still be supplied with medical gas Lateral and frontal reading of flow settings Higher number of flow disc holes increases treatment options Extra flow setting of 25 lpm on the traditional 15 lpm variant, allows use in resuscitation The additional 7 lpm is intended for nebulization Rotating pressure gauge which allows convenient reading Continuous flow between settings, in the unlikely event of mechanism failure swivelling outlet alows wider use of positioning Two windows - frontal and lateral allow very good visibility of set values 10
13 High pressure regulators MediSelect II Art. Nr. Type Gas Inlet Flow Inlet Outlet Pressure stem range connection connection outlet MEDISELECT II O 2 55 mm 0-2 l/min W21,8x1/14" 9/16 UNF MEDISELECT II O 2 75 mm 0-6 l/min W21,8x1/14" 9/16 UNF MEDISELECT II O 2 55 mm 0-6 l/min W21,8x1/14" 9/16 UNF MEDISELECT II O 2 55 mm 0-25 l/min W21,8x1/14" 9/16 UNF MEDISELECT II O 2 55 mm 0-25 l/min W21,8x1/14" 9/16 UNF SS QC MEDISELECT II O 2 39 mm 0-25 l/min W21,8x1/14" 9/16 UNF SS QC MEDISELECT II O l/min PIN INDEX 9/16 UNF MEDISELECT II O l/min PIN INDEX 9/16 UNF MEDISELECT II O l/min PIN INDEX 9/16 UNF MEDISELECT II O l/min PIN INDEX 9/16 UNF SS QC Technical data Gas O 2, Air, N 2 O, CO 2, N 2 O/O 2 Inlet pressure range up to 300 bar (depending on gas type) Nominal outlet pressure 4 bar Flow ranges* 0 to 2 lpm 0-0,1-0,2-0,3-0,4-0,5-0,6-0,7-0,8-1-1,5-2 Body material Control knob O-rings Filter Gauge cover Weight Regulatory status * Flowrates expressed at 23 C and 101,3 kpa Flow curve for oxygen (P2 = 4 bar) 0 to 6 lpm 0-0,25-0,5-0,75-1-1,5-2-2, to 25 lpm nickel-plated brass polyamide EPDM sintered bronze TPE (thermoplastic elastomer) app. 0,8 kg Complies with Medical Devices Directive 93/42/EEC. Complies with EN (Pressure regulators for use with medical gases) Complies with Standard EN 1789:2000 (Medical vehicles and their equipment - Road ambulances) Outlet pressure p2 [bar] Oxygen Flow Q [l/min] Spare parts Art. Nr. Type O-ring for outlet hose nipple 9/16 UNF, 10 pcs O-ring for inlet connection, EPDM, After , 10 pcs O-ring for inlet connection, EPDM, Before , 10 pcs Gasket for pin index connection, 10 pcs Pin index key 11
14 High Pressure Regulator MEDIREG II The new generation of medical high pressure gas regulators Regulator with flow selector Regulator with pressure outlet, constantly adjusted flow or with flowmeter Rotating pressure gauge which allows convenient reading Ergonomic and streamlined design Easy cleaning surface Compact and user friendly 360 Rotating pressure gauge which allows convenient reading Low weight Ergonomic Space saving gauge Compact 12
15 MediReg II Art. Nr. Type Gas Inlet Inlet Pressure stem connection outlet MEDIREG II O 2 55mm W21.8x14 SS QC MEDIREG II AIR 75 mm G5/8 SS QC MEDIREG II N 2 O 63 mm G3/8 SS QC MEDIREG II CO 2 76 mm W27x2 SS QC MEDIREG II O 2 + N 2 O PIN INDEX SS QC MEDIREG II AIR PIN INDEX SS QC Technical data Gas O 2, Air, N 2 O, CO 2, N 2 O/O 2 Inlet pressure range up to 300 bar (depending of gas type) Nominal outlet pressure Body material Control knob O-rings Filter Gauge cover Weight Regulatory status * Flowrates expressed at 23 C and 101,3 kpa Flow curve for oxygen (P2 = 4 bar) 4 bar nickel-plated brass polyamide EPDM sintered bronze TPE (thermoplastic elastomer) app. 0,65 kg Complies with Medical Devices Directive 93/42/EEC. Complies with EN (Pressure regulators for use with medical gases) Complies with Standard EN 1789:2000 (Medical vehicles and their equipment - Road ambulances) Outlet pressure p2 [bar] Oxygen Flow Q [l/min] Spare parts Art. Nr. Type O-ring for inlet connection, EPDM, After , 10 pcs O-ring for inlet connection, EPDM, Before , 10 pcs Gasket for pin index connection, 10 pcs Pin index key 13
16 High Pressure Regulator varimed Varimed is an one stage cylinder regulator with a large variety of applications The regulators are used for pressure monitors, anaesthetic equipment, transportation incubators, pain relief and similar areas Varimed has an easy-to-read gauge which shows the cylinder pressure, and a quick connection for easy connection of medical equipment Varimed has the latest regulatory technology and therefore has high operating reliability Varimed Art. Nr. Gas Inlet connection Inlet stem Inlet Pressure (mm) outlet QC Oxygen hand tight 63 W21,8x1/14" SS N 2 O hand tight 60 G3/8 SS Air nut, (short) inlet stem 47 G5/8 SS Oxygen nut, (long) inlet stem 69 W21,8x1/14" SS N 2 O nut, (long) inlet stem 47 G3/8 SS Air nut, (long) inlet stem 83 G5/8 SS Oxygen nut, (short) inlet stem 34 W21,8x1/14" SS 14
17 Varimed Technical data Gas Inlet pressure Outlet pressure Flow capacity O 2, Air, N 2 O O 2, Air bar N 2 O - 60 bar 4, 4.5 and 5 bar O 2-4,5 bar Air - 5 bar N 2 O - 4 bar see flow curves Outlet connection SS Body material Bonnet material Weight brass, nickel plated painted mazak 1,1 kg Flow characteristic of Varimed at P2=4 bar Flow characteristic of Varimed at P2=4,5 bar Flow characteristic of Varimed at P2=5 bar Spare parts Art. Nr. Denomination O-ring 10 pcs Oxygen Hand tight O-ring 10 pcs N 2 O Hand tight Al-washer 10 pcs Air Nut Washer 10 pcs Oxygen Nut Al-washer 10 pcs N 2 O Nut 15
18 High Pressure Regulator MMR MMR is a dual stage cylinder valve with automatic compensation for the gradual fall of pressure occuring in a gas cylinder when the gas is used An optimal field of application for the MMR is for the reserve gas cylinder that will be used, via the Pressure Monitor and Pressure watch, if an interruption in the gas supply occurs MMR has a very high flow capacity and gives the stable and even pressure necessary for certain medical gas applications The regulator is available for air and oxygen and has a preset working pressure A safety valve protects the equipment from overpressure 16
19 MMR - Dual Stage Regulator for Medical Use Art. Nr. Description Inlet Outlet connection connection MMR for breathing oxygen, P2= 4,5 bar W /14 G 3/ MMR for breathing air, P2=5 bar G 5/8 G 3/ MMR for I-air, P2=8 bar G 5/8 G 3/8 Technical data Weight Capacity ca 2400 gr Outlet according to standard SS Spare parts Art. Nr. Description Gas ca 30 m 3 /h at P1 = 200 bar ( kpa) and at P2 = 5 bar (500kPa) Washer inlet stem O 2 /Air 10 pcs Hoses Art. Nr. Gas Length (m) Inlet connection Outlet QC SS O G 3/8-6 mm Straight male N 2 O 1.3 G 3/8 LH - 6 mm Straight male Air 1.3 G 3/8-8 mm Straight male I-Air 1.3 G 3/8-8 mm Straight male A / 0 bar bar /
20 High Pressure Regulator GCE SABRE MEDICAL regulators The range covers the widest possible combination of inlet and outlet connections Includes products designed for oxygen therapy, for use with gas powered resuscitation and on demand equipment All offers unrivalled levels of accuracy and performance whilst maintaining Sabre s design brief of robust and simple to operate products leaving the carer to concentrate on their patient not on remembering how to use the equipment They incorporate both sintered bronze filters and pressure relief valves, minimising the risks of contamination and providing increased carer and patient safety 18
21 SABRE Select Flow Art. Nr. Description Outlet flow ranges Inlet SF.PI.O-11F1 regulator 1,0-23,0 l/min PIN INDEX SF.PI.O-11F3 REG only boxed 0,1-5,0 l/min PIN INDEX SF.PI.O-11F4 REG only boxed 0,1-1,1 l/min PIN INDEX SF.PI.O-11F5 Regulator boxed 0,5-15,0 l/min PIN INDEX SFB-PI.O-11 F2 REG BRASS boxed 0,25-23,0 l/min PIN INDEX SF-DN60-11F4 REG only boxed 0,1-1,1 l/min W / SF-DN60-11F5 REG only boxed 0,5-15,0 l/min W /14 Technical data Gas O 2 Input pressure up to 200 bar Therapy flows Therapy outlet Therapy pressure Weight (no outlets) all flow ranges 11 F4 0,1-0,2-0,3-0,4-0,5-0,6-0,7-0,8-0,9-1,0-1,1 11 F3 0,1-0,25-0,5-0,75-1-1,5-2-2, F5 0,5-0, F1 1,0-2,0-4,0-6,0-8,0-12,0-15,0-23,0 11 F2 0,25-0,5-0,75-1,0-2,0-4,0-6,0-8,0-12,0-15,0-23,0 firtree 1.6 bar (23psi) app. 0,51 kg SABRE Resuscitation Regulator Art. Nr. Description Outlet flow ranges Inlet RR-DN6O-AG-BP-1 RESUSREG PA 1,0-23,0 l/min W / RR-DN6O-AG-BP-5 RESUSREG PA 1,0-15,0 l/min W / RRB-DN6O-AG-BP-1 RESUSREG BRASS 1,0-23,0 l/min W / RRB-PI.O-AG-BP-1 RESUS REG B 1,0-23,0 l/min PIN INDEX Technical data Gas O 2 Input pressure up to 200 bar Therapy flows Therapy outlet Therapy pressure Weight All flow ranges Firtree 1.6 and 4.2 bar (60psi) app. 0,72 kg Spare parts Art. Nr. Description P O-ring (10pcs) Valve key & cord for PI regulator (1pc) P Screw assembly M10 for PI regulator (1pc) 19
22
23 HOSPITAL WARD EQUIPMENT
24 suction equipment medievac+ Compact and lightweight medical vacuum regulator system, which allows the user to efficiently and safely control suction therapy The suction level of the Medievac+ is regulated via an easy accessible, front mounted control knob A special feature of the Medievac+ on-off valve is easy resumption of the selected de-pressure value, when the treatment is interrupted The Medievac+ gauge can easily be rotated, allowing the vacuum pressure to be clearly viewed by the operator The gauge scale is colour coded in sections to display a clear indication of suction level Two versions of adjustable pressures are available to cover all therapy needs(-250 and 1000 mbar) The 250 mbar version has a safety valve, which will automatically shut off to guarantee maximum protection of the patient, in the unlikely event of de-pressure increase The compactness of the device offers: Fast connection to the vacuum source Quick and convenient mounting of accessories (for example safety jar) Good accessibility of other devices connected to close located terminal units 360 Diagonal orientation of ON/OFF switch Safety valve (- 250 mbar) for protection of the patient 22
25 hospital ward equipment Vacuum Regulator - Medievac+ Art. Nr. Description Jar Hose Probe connection Medievac With Nordic clamp G1/2 1 m angled male SS Medievac+ 250 With Nordic clamp G1/2 1 m angled male SS Medievac+ 1000/250 double With Nordic clamp G1/2 1 m angled male SS Technical data ON-OFF function Max. inlet pressure ON : green button visible To switch ON: push on the OFF button(red) mbar (inlet pressure at 1013 bar -15 C) Max. suction flow Medievac l/min ±5 l/min at 950 mbar Accuracy of gauge Safety valve Inlet connection Outlet connection Height (with jar) Width Depth Body material Regulatory status Medievac l/min ±5 l/min at 250 mbar ±2,5 % of full scale Medievac+ 250 only max mbar opening According to the respective national standard ISO G1/2 male 265 mm 55 mm 115 mm ABS Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Medical suction Equipment, Part 3: Suction equipment powered from a vacuum or pressure source) Accessories for Medievac The Medievac+ vacuum regulator system includes an optional accessory, the safety jar. It is an additional protection of the vacuum regulator and the hospital vacuum network, when the collection jars overflow. The filling capacity of 100 ml and the safety valve function, provide the user with extra time to stop the suction therapy. The jar can be easily and safely disconnected from the vacuum regulator and autoclaved at 134 C for 18 minutes, in line with hospital protocols. GCE Mediline also recommends the use of the front mounted filter that is connected on the safety jar for increased safety. The plastic shell of the filter is very convenient to mount; it enables hygienic handling as direct contact with the membrane is avoided. The use of this filter is also recommended by the standard (EN ISO part ). Medievac+ compliance is based on EN ISO standard. Art. Nr. Description Safety jar 100 ml Safety jar 100 ml including filter K Filter (x10) Olive suction tip large Olive suction tip small K Hose nipple G1/2 + o-ring 23
26 suction equipment medieject The suction ejectors Medieject-32 and Medieject-33 come with either a metal bracket for rail mounting, with a quick coupling for direct connection to gas outlet The negative pressure can be seen clearly on the front-mounted gauge The suction ejector has an ON/OFF control knob The suction effect is regulated with a needle valve It has a low sound level and requires a minimum of maintenance 24
27 Suction ejector - Medieject-32/Medieject-33 only DK Suction ejector for mounting on wall rail Art. Nr. Description Suction ejector Medieject-33 for 6/11 mm hose, breathing oxygen/air Suction ejector for mounting in gas outlet Art. Nr. Description Suction ejector Medieject-32 for breathing air/breathing oxygen Suction ejector with RAIL clamp Art. Nr. Description Suction ejector 1m hose and angled male probe, breathing air Technical data Maximal suction effect Capacity Maximum consumption of gas Dimensions (w h d) -80 kpa (-0,8 bar) >25 l/min 38 l/min mm (mounting on wall rail) mm (mounting in gas outlet version) mm (clamp version) 25
28 ACCESSORIES - Suction Bottles - WITH SINGLE USE BAGS Suction bottles - single used bags Art. Nr. Description Suction bottle 2 l Complete with lid Suction bag 2 l (20 pcs) Suction bottle 1 l Add lid art. no to make complete Suction bag 1 l (20 pcs) Accessories Art. Nr. Description Connection for suction bag Silicone hose; 25m; Silicone hose; 5m; Silicone hose; 1m; Lid for suction bottle Silicone hose; 5m; Silicone hose; 1m; 6 12 K K Catheter holder (without plate) Catheter holder (with plate) K K ACCESSORIES - Suction jars - MediCollect 2000 Medicollect 2000 is a range of reusable jars for collection of secretion. For protected and hygienic use of unbreakable material, guaranteed airtight, with an overflow valve and autoclavable material. Art. Nr. Description K Medicollect 2000 with lid (134 C) K Medicollect 2000 with lid (121ºC) K K Accessories and Spare Parts Art. Nr. Description K Rail clamp plastic for slitz plate K Jar 134 ºC K Complete overflow valve Consumables Art. Nr. K Description Manual vacuum stop device, non sterile for adults Technical data Dimensions Weight Capacity Pressure Maximum flow Anti-overflow arrangement Material Connections Cleaning Maintenance Durability Height 302 x Ø 135x Ø130 mm 0,6 Kg 2 l Maximum applicable 950 mbar Minimum applicable 100 mbar 100 l/min Ball valve Jar: polysulphone (134 C), polycarbonate (121 C) Lid: polypropylene Hose nipples: chrome plated brass. Hose nipples - Ø 9 mm Use a non abrasive cloth moistured with a neutral detergent immerged at 10% in hot water, < 60ºC. Rince in pure water and dry well. Never use solvents. Autoclave at 121 ºC for 30 minutes. Check air tightness every six months or every five cleaning cycles. Check the overflow valve every six months or every ten cleaning cycles. Maximum 30 autoclave cycles. 26
29 Flow-metering device medimeter Medimeter is a flowmeter intended for control and measurement of flow of air or oxygen administered to patients Flat surface float allows easy and safe reading of flow values by the users Ergonomic design, easy for cleaning Available with probe connector, rail mounting with a hose and twin versions Soft closing mechanism Resistant float against impact New scale - better reading of flow values 27
30 Flowmeter - MediMeter Oxygen Art. Nr. Description l/min Outlet Inlet connection Hose Hose colour MM UNF9/16" SS-90 -CLAMP NORDIC 1,0 white MM5 0-5 UNF9/16" SS-90 -CLAMP NORDIC 1,0 white MM15 2x 0-15 UNF9/16" SS-90 -CLAMP NORDIC 1,0 white MM UNF9/16" Straight Male SS NO MM5 0-5 UNF9/16" Straight Male SS NO MM UNF9/16" SS-90 -CLAMP EU 1,0 white MM5 0-5 UNF9/16" SS-90 -CLAMP EU 1,0 white MM15 2x 0-15 UNF9/16" SS-90 -CLAMP EU 1,0 white Medical Air Art. Nr. Description l/min Outlet Inlet connection Hose Hose colour MM UNF9/16" SS-90 -CLAMP NORDIC 1,0 black/white MM15 2x 0-15 UNF9/16" SS-90 -CLAMP NORDIC 1,0 black/white MM UNF9/16" Straight Male SS NO MM UNF9/16" SS-90 -CLAMP EU 1,0 black/white MM15 2x 0-15 UNF9/16" SS-90 -CLAMP EU 1,0 black/white Technical data Gas Inlet pressure Flow ranges Body material O-rings Control knob Body dimensions O 2, Air 4,5 bar 0-5 lpm 0-15 lpm Nickel-plated brass EPDM Polyamide Width 32 mm Height 160 mm Depth 60 mm Weight 280 g (without connector) Temperature range Storage - 30 C to + 60 C Operation - 20 C to + 60 C Regulatory status Complies with medical devices directive 93/42/EEC Complies with EN (Flow - metering devices for connection to terminal units of medical gas pipeline systems) Accessories Art. Nr. Description K MediWet C G 9/16 spare parts Art. Nr. Denomination External tube (10 pcs) O-ring (20 pcs) Hose nipple 9/16 UNF with o-ring (10 pcs) 28
31 Flow-metering device MEDIFLOW ULTRA II MediFlow Ultra II is the new generation of medical flow selector device with built-in regulator It covers a comprehensive combination of inlet and outlet connections and offers various options for all medical applications, from neonatal care through to resuscitation Built-in regulator provides a very stable and precise flow, independent of the pressure in the medical central gas system or cylinder Innovative self centering flow setting device with continuous flow between settings. In the unlikely event of indent mechanism failure, the patient will still be supplied by medicinal gas Lateral and frontal reading of flow settings 360 swivelling outlet it enables better orientation of the nasal cannula or oxygen mask towards the patient (preventing from twisting) Higher number of flow disc holes increases treatment options. Extra flow setting of 25 lpm on the traditional 15 lpm variant, allows use in resuscitation. The additional 7 lpm is intended for nebulization Ergonomic and streamlined design Independence of the pressure fluctuation with inlet pressure range of 2,8 8 bar Continuous flow between settings, in the unlikely event of mechanism failure 360 Two windows - frontal and lateral allow very good visibility of set values 360 swivelling outlet alows wider use of positioning 29
32 Mediflow Ultra II (Low Pressure Regulator) Art.Nr. Type Gas Flow Inlet Outlet range connection connection MEDIFLOW ULTRA II O l/min SS probe 9/16 UNF MEDIFLOW ULTRA II O l/min SS probe 9/16 UNF MEDIFLOW ULTRA II O l/min SS probe 9/16 UNF MEDIFLOW ULTRA II O l/min Nordic clamp 1 M hose + SS probe angled 9/16 UNF MEDIFLOW ULTRA II O l/min Nordic clamp 1 M hose + SS probe angled 9/16 UNF MEDIFLOW ULTRA II O l/min Nordic clamp 1 M hose + SS probe angled 9/16 UNF Technical data Gas Inlet pressure range Max.outlet pressure with no flow O 2, Air 2,8 8 bar 2,1 bar Flow ranges* 0 to l/min 0-0,1-0,2-0,3-0,4-0,5-0,6-0, 7-0,8-1-1,5-2 Body material Control knob O-rings Filter Diameter Length Weight Regulatory status 0 to 6 l/min 0-0,25-0,5-0,75-1-1,5-2-2, to 25 l/min nickel-plated brass polyamide EPDM sintered bronze and stainless steel 39 mm 77 mm 350 g Complies with Medical Devices Directive 93/42/EEC. Complies with EN (Pressure regulators for use with medical gases-low pressure regulators) Complies with Standard EN 1789:2000 (Medical vehicles and their equipment-road ambulances) MediFlow II 50 l/min (flow selector) Mediflow II 50 lpm is a flow selector intended for use for resuscitation and for CPAP. Art.nr. Type Mediflow II 50 lmp Technical data Gas 0 2 Inlet pressure range 4,5 bar Flow ranges 0 to 50 lpm Inlet connection Outlet connection Body material Control knob O-rings Body dimensions Regulatory status SS probe 9/16" UNF nickel-plated brass polyamide EPDM Diameter: 40 mm Length: 75 mm Weight: 350 g Complies with Medical Devices Directive 93/42/EEC. Complies with ISO (Flow-metering devices for connection to terminal units of medical gas pipeline systems) Complies with Standard EN 1789:2000 (Medical vehicles and their equipment-road ambulances) spare parts Art. Nr. Denomination Hose nipple with O-ring G3/8 (10 pcs) Hose nipple 9/16" UNF, hose Ø6-8 mm (after ) (10 pcs) O-ring 9,75 1,78 NBR 70SH (after ) (10 pcs) 30
33 ACCESSORIES - MediWet II Humidifier The humidifier for oxygen therapy is a device allowing an increase in the relative humidity in the oxygen supplied to the patient. Art. Nr. Description K Mediwet II 134 ºC inlet connection 9/16 UNF F K Mediwet II 134 ºC inlet connection G 3/8 F K Technical data Contents Only sterile water Dimensions Height 190 Width 67 (incl hose nipple) Ø 57 mm Weight Polysulphone version 115 g Capacity 200 ml of water Consumption 6 ml of water per hour at a gas flow of 10 l/min at 20 ºC Material Jar autoclavable at 134 ºC: polysulphone Lid and outlet hose nipple: polypropylene Inlet nut: Chromed brass Diffuser: Polyethylene Hose, flat gasket: Silicone Gasket: O-ring EPDM Outlet connection Tapered hose nipple for hose 6x9 mm (recommended length 2 m) Cleaning Water, non abrasive detergent. Never use solvents. Disinfection An alcoholic solution, or other solution compatible with the material according to the disinfectant manufacturer. Autoclave Polysulphone version 134 ºC for 18 minutes Special case Diffuser: exchange at every cleaning - do not sterilise! Maintenance Check that the humidifier is whole and air tight before use. Monthly exchange of gaskets is recommended. Exchange the diffuser when its microperforations no longer exist. Durability Minimum 20 autoclave cycles under the condition that all instructions accompanying the product are adhered. Spare Parts Art. Nr. Description K Jar 134 ºC K Lid 134 ºC connection 9/16 UNF K Lid 134 ºC connection G3/8 K Inlet connection gasket 9/16 UNF, 10 pcs K Bottle gasket 134 ºC, 10 pcs Consumables Art. Nr. K Description Complete diffuser (tube 13 cm and diffuser, 10 pcs) 31
34 Low pressure hoses The dimensions and colours of our polyvinyl chloride manufactured, textile-reinforced hoses are in accordance with the current hospital standard. Allowed working pressure max. 14 bar. The hoses for medical breathing oxygen and nitrous oxide are marked with the chemical denomination of the gas. The medical breathing air hose is marked Air. Static. Phthalates free Art. Nr. Denomination Colour Max. Dimension Roll pressure (inner/outer) Medical breathing oxygen White 14 bar 6/11 30 m Nitrous oxide Blue 14 bar 6/11 30 m Medical breathing air Black/white 14 bar 8/14 30 m Medical Breathing Air Black/white 14 bar 6,7/12,7 30 m Gas outlet Blue/brown 14 bar 12/17,4 30 m Vacuum/UTS Yellow 14 bar 10/16 30 m Carbon dioxide Grey 14 bar 6/11 30 m Mixed gas Red 14 bar 6/11 30 m O 2 /N 2 O White/blue 14 bar 6,7/12,7 30 m Suction hose Transparent - 6/12 25 m 32
35 Low pressure Hoses - MediConnect MediConnect is a new generation of flexible hoses for gas supply, intended for use with respiratory, anaesthetic and emergency equipment. Resistant to abrasion and change of colour Containing antistatic inner layer Neutral colours or according to colour coding of EN ISO 5359 Wide range of country specific connections Lengths of hoses from 0,5 to 5 m; to be specified by customer Phthalates free Technical Data Gas pressure O 2, Air, N 2 O, vacuum Material Polyvinyl chlorid, containing plasticizer, with brilliant polish, antistatic Inner/outer diameter 6,7 12,7 mm Wall 3 mm Hardness (Shore A) 88 ± 5 Density 1,25 ± 0,02 g/cm 3 Tensile strength = 10 MPa Fracture strain = 200 % Working pressure max. 14 bar / 20 C Rupture pressure 56 bar / 20 C respectively 40 bar / 40 C Operation temperature - 20 C to + 60 C Nordic Standard Probe French Standard Probe British standard probe German Standard 120 Probe 33
36 RAILS Rail Complete (30 10 nordic), without screws Art. Nr. Denomination (meter) Material ,0 Aluminium ,5 Aluminium ,0 Aluminium ,0 Aluminium P* 3,0 Aluminium * Only rail, without end protection washer and distance Accessories Art. Nr. Denomination Material P End protection (10 pcs) Plastic P Washer (10 pcs) Aluminium Distance 20 mm Aluminium Multiflex Rail (30 10 nordic) Art. Nr. Denomination (meter) Material ,0 Aluminium Accessories Art. Nr. Description Material Wall fixing with distance Aluminium P End protection (10 pcs) Plastic EU Rail Complete (25 10 EU), without Screws Art. Nr. Denomination (meter) Material ,0 Stainless Steel ,5 Stainless Steel ,0 Stainless Steel ,0 Stainless Steel * 3,0 Stainless Steel * Only rail, without end protection washer and distance Accessories Art. Nr. Description Material Distance 20 mm Stainless Steel Washer D 40 mm Stainless Steel End protection Plastic 34
37 clamps Clamps Art. Nr. Description 81366EU EU Clamp for 25x10 mm rail, with T-plate fitting Universal Rail Clamp for 30x10 mm rail, with T-plate fitting Universal Lamp Clamp for 30x10 mm rail, 13 mm Universal Lamp Clamp for 30x10 mm rail, 9,6 mm Universal Clamp for 30x10 mm rail (left) with plain back 81389V Universal Clamp with plain back, for 30x10 mm rail 81389EU EU Clamp with plain back, for 25x10 mm rail 81431EU Double EU Clamp with plain back, for 25x10 mm rail Double Universal Clamp for 30x10 mm rail Double Universal Clamp for 30x10 mm rail with tailstock barrel EU 81431EU EU 35
38 trolleys Trolleys Art. Nr. Description Trolley for 10 l cylinder, 5-wheels, static P Trolley for 10 or 20 l cylinder, without belt Dimensions H W D (mm): Trolley for 10, 20 l cylinders, 3 10 l or 2 20 l without belt Dimensions H W D (mm): Trolley for gas cylinder, D=116 mm P Accessories Art. Nr. Description Trolley Belt for 2.5 l cylinder P Belt for 5 or 10 l cylinder P, , Belt for 20 l cylinder , Cylinder Holders Cylinder Holders Art. Nr. Description Holder for 2 l cylinder (1 belt). D = 100 mm Holder for 2 or 3 l cylinder (2 belts), D = 100 mm Holder for 2 l cylinder (foot) P Holder for gas cylinder, D = 116 mm P Holder for gas cylinder, D = 100 mm P Accessories Art. Nr. Description Bed hanger bracket T-Bracket 36
39 quick couplers Quick Couplers - Male Male angled SS Art. Nr. Denomination O 2 6 mm N 2 O 6 mm Air 8 mm Air 6 mm Vacuum 10 mm Instrument air 8 mm Gas outlet 12 mm P Vacuum 6 mm Male angled DIN Art. Nr. Denomination O 2 6 mm N 2 O 6 mm Air 6 mm Vacuum 6 mm Male angled non-return valve SS Art. Nr. Denomination O 2 6 mm N mm Air 6 mm Male straight SS Art. Nr. Denomination O 2 6 mm N 2 O 6 mm Air 6 mm Air 8 mm Nitrogen 6 mm P CO 2 6 mm Instrument air 8 mm Vacuum 6 mm Vacuum 10 mm Gas outlet 6 mm Gas outlet 12 mm Mix O 2 /N 2 O 6 mm Male straight NIST Art. Nr. Denomination O 2 6 mm N 2 O 6 mm Air 6 mm Vacuum 6 mm Male straight non-return valve SS Art. Nr. Denomination O 2 6 mm N 2 O 6 mm Air 6 mm 37
40 Quick Couplers - Female Female with hose socket SS Art. Nr. Denomination O 2 6 mm N 2 O 6 mm Air 6 mm Air 8 mm Vacuum 6 mm red Vacuum 6 mm yellow Vacuum 10 mm yellow CO 2 6 mm Instrument air 8 mm Gas outlet 12 mm O 2 /N 2 O Mix 6 mm Female with thread SS Art. Nr. Denomination O N 2 O Air Vacuum red Vacuum yellow Nitrogen CO Instrument air Gas outlet O 2 /N 2 O M18 1,5 LH Female with thread DIN Art. Nr. Denomination O 2 G1/ O 2 G3/ N 2 O G3/ Air G1/ Air G3/8 Hose sockets with nut Art. Nr. Denomination Thread P O 2 6 mm G3/ N 2 O 6 mm G3/8 LH Air 8 mm G3/ I-Air 8 mm M18 Hose sockets with nut Art. Nr. Denomination way hose socket 6 mm 38
41 Double Outlets Double SS outlet UNI rail clamp (30 10=nordic), 1 m hose and angled probe Art. Nr. Denomination Oxygen N 2 O Air Vacuum Double outlet T-piece quick coupling Art. Nr. Denomination Oxygen Air ACCESSORIES Accessories Ward P Art. Nr. Description P Hose holder for mounting on rail Rail Clamp Univ. with Hook Curved Rail Clamp EU with Hook Curved P Single slits attachment wall (AL) inclusive screws and plugs P Single slits attachment wall (AL) exclusive screws and plugs P Triple slits attachment wall (AL) exclusive screws and plugs Wall attachment MS-313 (plastic) inclusive screws and plugs ISO connection 2x22/15mm, polycarbonate, blue P ISO connection 2x22/15mm, polycarbonate, with conic hose socket, red, 10 pcs Olive suction tip large Olive suction tip small Hose socket 9/16 UNF Universal clamp complete with stainless steel cylindric jar Stainless steel cylindric jar Rail clamp for plate, chromium plated Rail clamp - hung for plate, chromium plated Wall bracket for plate, chromium plated K Rail clamp plastic for slitz plate and and
42
43 HOMECARE
44 HOW TO SAVE OXYGEN? USE ELITE OR ECOLITE 4000 AND SAVE 3 UP TO 10 TIMES THE OXYGEN COMPARED TO CONTINOUS FLOW sabre elite During exhalation oxygen collects in a reservoir. At the start of the inhalation, the diaphragm detects the negative pressure in the nose. This opens a valve delivering the oxygen to the patient at the start of the breath. The oxygen delivered correlates closely to the established method of constant flow across a range of breathing rates. The Sabre Elite automatically adjusts oxygen delivery on a given setting to the patient s breathing rate. For higher breathing rates there is less time for the oxygen to collect. The patient will therefore get smaller pulses, but more of them. For lower breathing rates there is more time for the oxygen to collect. The patient will therefore get larger pulses, but less of them. A simple way of looking at oxygen savings by considering efficiency. The % efficiency is calculated by dividing the oxygen delivered to the lung by the total flow delivered. In constant flow delivery only a small proportion of oxygen gets into the lung where it can be absorbed. About 60% to 80% of the oxygen delivered is wasted. Efficiencies are in the region of 20% to 40%. The reasons for this are: Constant flow does not stop during exhalation, so two thirds of the gas is wasted by flowing into the atmosphere. Constant flow delivers throughout inhalation including the gas that goes into the dead-space. The Sabre Elite delivers more efficiently. Efficiencies are in the region of 90% to 70%. The pulse of oxygen is at the start of the breath where the gas is mixed with air that goes into the lung to be absorbed.during the later part of inhalation (where the oxygen would otherwise go into dead-space) and duringexhalation the Sabre Elite saves the gas. The oxygen saving factor is primarily derived from efficiency, but other factors are relevant. The traditional constant flow settings of 2 and 4L/m are limited. By having a large range of settings with smaller increments significant further savings are possible. The Sabre Elite has a saving factor of approximately 3 based on efficiency. If the incremental saving of having a wide range of settings that will accurately meet the patient s need is taken into account, a saving of = 4.8 may be claimed. The Elite Set is supplied with a strapped carry bag Cylinder and Nasal Canulae. Cylinder Duration Table Approximate duration in hours: minutes for Elite Cylinder capacity (litre) Pressure (bar) Flow equivelency settings (L/min) :25 1:42 1:80 0:51 0: :51 3:25 2:17 1:42 1: :38 5:49 3:52 2:54 1: :42 6:51 4:34 3:25 2: :29 9:14 6:90 4:37 3: :35 32:17 21:31 16:80 10: :00 2:30 1:40 1:15 0: :00 5:00 3:20 2:30 1: :00 8:30 5:40 4:15 2: :00 10:00 6:40 5:00 3: :00 13:30 9:00 6:45 4: :17 47:80 31:26 23:34 15:43 42
45 HomeCare ELITE - Pneumatic Gas conserver The innovative ELITE oxygen conserving device conserves oxygen, and thus prolongs the service life of the cylinder. Elite also increases the mobility of the patient. Thanks to the system s precision metering, the O2 cylinders last approximately 3 times longer than with simple pressure regulators without a conserving system, without any loss of therapeutic effect. ELITE offers major advantages: Ease of handling. Just screw a pressure regulator onto the cylinder, turn the cylinder on, adjust the flow rate at the rotary switch and you are ready to go. No batteries required. You can save money, and potential sources of error are removed. The special rotatable pressure gauge can be read easily from all angles. No expensive special masks. Wear your normal standard nose mask. The light weight (580 g incl. pressure regulator), the ease of handling and the robust design offer patients optimum suitability for everyday use and maximum comfort. Elite with High Pressure Cylinder Connector Art. Nr. Description Elite valve and regulator with Pin Index connection Elite valve and regulator with DN6 = W21,8 Technical data Input pressure bar Inlet Connector Type(s) Full range high pressure Pressure gauge bar low profile Therapy flow Equivalency (lpm) 1,0-1,2-1,5-2,0-2,5-3,0-3,5-4,0-4,5-5,0-5,5-6,0 Pressure Relief Valve Pressure 7 bar Therapy outlet Universal firtree Service Intervals Elite - 3 Years Nasal Canulae Part Numbers (pack of 100) Acessories Art. Nr. Denomination Elite - Carrying bag Elite-Trolley 43
46 oxygen conserving device ECOlite 4000 ECOlite 4000 is an electronic oxygen gas conserving device, which enables patient friendly and efficient long term oxygen therapy treatment (LTOT). With the ECOlite 4000, oxygen is delivered only during the inspiration phase, permitting savings of up to 10 times compared to continuous flow oxygen therapy The volume of oxygen needed for one breath is delivered during the first third of the inspiratory cycle, which guarantees both efficient and optimal treatment and a short exposure of the nasal mucosa to medical oxygen. A special feature of the ECOlite 4000 is the small, internal regulator, that allows the user to select a supply inlet pressure of between 1,6 to 5 bar. The working pressure of the device is regulated to 1,6 bar which enables a both clinically and physiologically patient friendly oxygen administration. The device has two operating modes, Automatic and Manual In the Automatic mode the amount of oxygen delivered increases in relation to the set flow rate at breath rates of 15 to 30 breaths per minute, to a maximum of 8 lpm. In the Manual mode the flow rates are from 0,5 to 8 lpm with 0,5 lpm steps If a specific flow rate is prescribed by the physician to be administrated, the flow settings can be locked at any rate by the health care personnel in charge of setting the flows on initial setup The device has several built in alarm functions for safe use. The alarms are shown on the display and are also audible The ECOlite 4000 has alarms for: Low battery No oxygen No breathing The battery life time of the device is prolonged to last for 200 hours. Standard AA 1,5 volt batteries are in use. 44
47 ECOlite 4000 Oxygen Conserver Environmental Protection There are no known risks associated with disposal the ECOlite 4000 at the end of its working life. Batteries and electronics should be disposed of at an approved recycling facility. Other parts shall be recycled according to local regulations. Regulatory Status European Economic Area (EEA): This mark on the product indicates compliance with Directive 93/42/EEC relating to medical devices, Class IIa Liter/min 0434 Automatic mode Patented 85,0 80,0 75,0 70,0 65,0 60,0 55,0 50,0 45,0 40,0 35,0 30,0 25,0 20,0 15,0 10,0 5,0 8 0, Breath/min Setting Manufacturers Information The ECOlite 4000 is manufactured at GCE. The month and year of manufacture is shown on the serial number label on the rear of the unit. Other than the consumables/accessories/spare part listed above there are no user replaceable parts. Only qualified service personnel, certified by the manufacturer, may attempt any repair to the ECOlite Not following this instruction will disqualify the manufacturers guarantee. Art. Nr. Description ECOlite 4000 COMPL SE ECOlite 4000 COMPL 1,6 BAR Consumables Art. Nr. Description P Standard Nasal cannula, 10 pcs Spiral Hose SE Spiral Hose 1,6 bar Accessories Art. Nr. Description ECOlite 4000 Carry Bag ECOlite 4000 Carry Bag Trolley Belt bag for ECOlite 4000 Spare Parts Art. Nr. Description Battery cover Technical data Functional performance Settings Manual/Automatic Triggering At each breath Sensitivity 0,13 cm H 2 O Regulating pressure 1,6 Bar Accuracy 0,5-1,5 l/min +/- 30% 2-8 l/min +/- 15% Cycle output 0.5 to 8 l/min coresponding to 5-80 ml per bolus Alarms Battery monitoring Missing Oxygen supply No inhalation Power supply Battery Oxygen supply Pressure Flow Dimensions and weight Dimensions Weight RO6, AA, Alkaline 1,5 V Between 1,6 and 5 Bar Minimum 4 liters per minute Height: 101 mm Width: 85 mm Depth: 32 mm 184 g without battery Environmental condition Ambient temperature Operational -10 C to +40 C Storage -40 C to +70 C Relative humidity 25% to 95% 45
48 accessories for gas saver Art. Nr. Description Oxygen mask for adults under chin, single use Technical Data Hose length Material PVC Connection Package 2.1 m Soft material for best wearing comfort and optimal patienthandling Standard 50 pcs Art. Nr. Description Oxygen mask for children age to 1 to 10+, single use Technical Data Hose length Material PVC Connection Package 1.8 m Soft material for best wearing comfort and optimal patienthandling Standard 50 pcs Art. Nr. Description Nasal cannula Technical Data Hose length Package 2.1 m 50 pcs Art. Nr. Description Nasal cannula, flared Technical Data Hose length Package 2.1 m 50 pcs
49 EMERGENCY EQUIPMENT
50 demand valve EASE II The New Sabre EASE II portable systems provide a compact low resistance method of self-administering O 2 or O 2 /N 2 0. The EASE demand valve is constructed in a way that creates minimal breathing resistance to the patient and can deliver high flows when required. For greater user comfort the EASE II is both smaller and lighter than the original Sabre EASE. The new Easy Grip handle is another user friendly addition. On demand Oxygen or Nitrous Oxide/ Oxygen system for delivering up to 300 litres/ min Portable first stage regulator and cylinder version for immediate care and pre-hospital applications. Low pressure pipeline version for obstetrics and general nursing applications. Conforms to BS 4272: Part 2: 1996 Low inspiratory effort demand valve Test/ Purge facility on the demand valve, easy to clean and reassemble for cross infection protocol Hose fitted with probes by the national standards for connection into cylinder system or wall outlet Autoclavable, removable handle The EASE II system is available to deliver Nitrous Oxide/ Oxygen upon demand. It is available for use as a portable system with first stage regulator, or as a low pressure pipeline version. The EASE is designed to administer effective pain relief within a wide range of medical situations including immediate care, general practice and general nursing obstetrics. Conforming to BS 4272: Part 2:1996, the demand valve is designed to deliver up to 300 litres per minute of gas with minimal inspiratory effort by the patient. This valve also contains a removable patient valve that houses the exhalation flap and anti contamination valve. This can be removed and cleaned before replacement and re-use. Options The Sabre EASE range of products is structured in a way to allow the user to define their personal requirements of system, cylinder and carry options. 48
51 Emergency Equipment Demand Valves - EASE II Art. Nr. Gas Type Group Co. Ease II Variant Description O 2 /N 2 0 SE EASE II, 3 m hose, SS probe O 2 SE EASE II, 3 m hose, SS probe Technical data Demand Valve Gas N 2 O/O 2, O 2 Material Polycarbonate, silicone rubber, stainless steel Dimensions mm Weight 0,085 kg Gas supply Requirement 2,8 to 7,0 bar and 200 L/min Inspiratory resistance (At 2,8 bar supply press.) Cracking -0,15-0,2 kpa -0,2 kpa at 10 L/min -0,7 kpa at 200 L/min Expiratory resistance Cracking Zero At flow +0,35 kpa at 120 L/min Operating temperature -20 C tp +60 C used Oxygen +5 C to +40 C used 50/50 N2O/O2 Storage temperature -30 C to +60 C Hose Assembly Connection Probes by the national standards Working pressure 7 bar Burst pressure 56 bar/23 C and 40 bar/40 C Material PVC, anti-static in accordance with ISO 5359 Weight 0,5 kg (3 m length) Accessory to EASE II Art. Nr. Description Case boxed c/w strap and frame Disposable mouthpiece (Pack of 5 pcs) P Breathing filter (Pack of 5 pcs) P Disposable facemask - medium (Pack of 5 pcs) P Adult size reusable mask P Child size reusable mask Thermometer for N 2 O/O 2 cylinders Blue barrel carry bag P Adult/Child size mask, multiple use for Ease II P Expiration diverter single use for Ease II (Pack of 1 pce) 49
52 Bag Valve Masks Compact resuscitator with mask extension tube, for emergency respiration. Made from silicon rubber and autoclavable up to 136 C. Supplied with mask, oxygen reservoir, oxygen tube and mask extension tube. a) Masks a) mask, b) oxygen reservoir, c) oxygen tube, d) mask extension tube c) b) d) Art. Nr. Description Bag Valve Mask kit Technical data Code 01 Size Adult Bellow Capacity 1500 ml Oxygen Reservoir Capacity 2600 ml Face Mask Size # 4 and 5 Mask Extension Tube 300 mm Material Bellow Silicon Rubber Extension Tube Silicon Rubber Masks 4 & 5 Polycarbonate and Silicon Rubber Non-Return Valve Polycarbonate Diaphragm Silicon Rubber Reservoir Valve Polycarbonate Reservoir Diaphragm Silicon Rubber Oxygen Reservoir Bag PVC* Oxygen Tube & Adaptor PVC* (Tube Length 2 meters). *Polyvinyl Chloride Note: Product is Latex free. Guedele Airways are designed to maintain an unobstructed oropharyngeal airway during or following general anaesthesia and in patients who are unconscious for other reasons. Integral hard bite block avoids airway occlusion and biting of tongue. Stepless airway path for easy cleaning. Bite blocks are colour coded for instant identification of sizes. Each kit contains 2 pieces each of sizes 2, 3 & 4. Manufactured from non-toxic, non-irritant polymer PE. Individually packed in peelable soft blister pack. Sterile ready for use. Art. No P P Denomination Child silicone mask with multi-function mask cover Adult silicone mask with multi-function mask cover Technical data Material Mask: Silicone (Si) Multi-Function Mask Cover: Polysulfone(PSU) Head Strap: PolyVinylChloride (PVC) Attachment Ring: Polysulfone (PSU) Operating Environmental Conditions -18 C to 60 C 15% to 95% relative humidity Storage Environmental Conditions -40 C to 70 C 40% to 95% relative humidity Patient port on mask fit standard 15/22 mm connectors Product is in compliance with essential requirements of council directive 93/42 EEC Medical Device Directive 50
53 ambulance panel ambulance panel II The Ambulance Panel II is the next generation of ambulance panels. It is designed for permanent installation and use in road ambulances. Long experience in this market has resulted in a product that gives the customer a lot of options and flexibility. Flexibility Due to the design and functions there are a big range of variants available. The functions and variants can be combined upon customer s request. Modular The modular concept means that same components can be used for many variants, resulting in short lead times and full flexibility. The Ambulance Panel II is designed with same shape for recessed and exposed. Gauge Outlet Quick Couplings Manual switch-over 51
54 Ambulance gas panel II Art. Nr. Description Number Type Version Switch Gauge Mediflow Medieject of QC of QC AP II O2 2xSS G3/8 R. 2 SS R AP II O2 R S R x AP II O2 2xFLS MEJ E. E * AP II O2 4xSS G S O E. 4 SS E x x AP II O2 1xMFII G3/8 E. E AP II O2 1xMFII G3/8 DD E. DR AP II O2 S G3/8 E E x AP II O2 2xFLS E. E AP II O2 S G E. E x x AP II O2 R S R x AP II O2 4xSS G3/8 R 4 SS R AP II O2 S G R. R x x * Extra 3/8 con. Recessed Recessed mounting is when the ambulance panel is mounted in the wall. The inlet could either be mounted at the end or at the back depending on the wall construction and the space behind the wall. The only part that will be outside the wall is the quick connector. Recessed Exposed Sketch of expossed mounted panel Sketch of recessed mounted panel Sketch of double recessed mounted panel Inlet Quick Couplings Exposed Exposed mounting is when the ambulance panel is mounted on the wall in the ambulance. The inlet could as the recessed, also be located at the end or at the back. When using the end inlet the hoses are fastened on the wall and fully visible. For some countries and regulations this is a must and the Ambulance Panel II has the features complying to these requests. The panel is fastened easily by 4 screws. Depending on the wall construction the fastening could either be done by a counter fastening frame or nuts and washers. Inlet The inlet connection the the Ambulance Panel II is standard 3/8 thread. This is a standard thread with conical sealing that has been used many times in this kind of application. Using a threaded connection gives the assembly easier and the parts easy to maintain and exchange. Quick Couplings There are many variants of quick couplings on the Ambulance Panel II. The most frequent standards are used on the Ambulance Panel II. For special quick couplings please contact GCE. By using standard components and quick couplings the assembly is easy and the maintenance access able and effective. Outlet Manual switch-over Outlet The outlet is standard 3/8 thread connection. If additional panels are needed, the Ambulance Panel II can have extra outlets for panels mounted in series. The panels are then connected with a standard hose and hose connections. Manual switch-over The manual switch-over is a selector that chooses what cylinder is supplying the ambulance panel. There are three steps 1-0-2, where the 0 is off 1 is cylinder one and 2 cylinder two. The manual switch-over can be incorporated in the panel beside the other quick couplings or it could be mounted separately. 52
55 Gauge One of the additional functions in the Ambulance Panel II is the gauge on the panel. The gauge is showing the working pressure in the system and gives continuously surveillance and is fully visible by the staff in the ambulance. Gauge Flowselector flowselector The AP II module can be equipped with a flow selector. The flow selector is permanently attached to the AP II module and can be delivered with the flow settings 0-15 and 0-25 liter per minute. This integrated module gives the AP II a compact design and minimize the products sticking out from the wall. Suction The integrated suction ejector is a variant in the AP II system giving the end user a complete range of functions. The suction ejector uses the pressure in the system to create suction by the venture principle. The unit is operated by a simple on of button and a regulating knob to adjust the negative pressure. Ambulance Panel System (APS) The complete installation of the ambulance panel, hoses and regulators is called Ambulance Panel System. Suction Technical Data Weight QC standards example AP II O 2 2xSS R: 754g SS Gases O 2 Standards EN 1789:2008 Classification Class IIb DIMENSIONS: Reccesed mounting exposed mounting
56 ambulance regulators medireg II varimed The Ambulance regulators are regulators specifically for use in road ambulances. GCE has long experience with regulators and ambulance oxygen supply systems, and this has resulted in a new range of ambulance regulators, and to meet the requirements on the market. MediReg II with electronic signal gauge The Medireg is a new developed regulator in the GCE group. GCE has now adapted the Medireg with a signal gauge suitable for road ambulances. The Medireg with electronic gauge is suitable for ambulances with low to medium capacity needs. The Medireg together with the new ambulance panel products, GCE can offer a complete system for ambulance builders and ambulance services. varimed with electronic signal gauge The Varimed is the regulator suitable for road ambulances with medium to high capacity needs. The Varimed regulator is a product well established on the market. Together with the new concept of integrating the electronic gauge, GCE offers a range well suitable for the ambulance market. 54
57 AMBULANCE REGULATORS MediReg II with electronic signal gauge Technical data Gas O 2 Inlet pressure range up to 200 bar Nominal outlet pressure Inlet connection Outlet connection Body material O-rings Filter Regulatory status Classification Flow curve for oxygen (P2 = 4 bar) 4 bar according to national standards according to national standards or specification nickel-plated brass EPDM sintered bronze Complies with Medical Devices Directive 93/42/EEC. Complies with EN (Pressure regulators for use with medical gases) Complies with Standard EN 1789:2000 (Medical vehicles and their equipment - Road ambulances) Class IIb 98.5 Ø55 W21,7x14 66 G 1/4 varimed with electronic signal gauge Art. Nr. Denomination Varimed O 2 Technical data Gas O 2 Inlet pressure range up to 200 bar Nominal outlet pressure Inlet connection Outlet connection Body material Filter Regulatory status Classification 4 bar W21,8 1/14" QC SS Nickel-plated brass; Komaxit plated mazak (ZnA84) Stainless steel Complies with Medical Devices Directive 93/42/EEC. Complies with EN (Pressure regulators for use with medical gases) Complies with Standard EN 1789:2000 (Medical vehicles and their equipment - Road ambulances) Class IIb Ø55 WIKA 172 W21.8x
58 Gauge with Electrical Output Signal (same for MediReg II and Varimed) Technical data Design Bourdon Tube EN Nominal size Accuracy class 2.5 Scale ranges 50 mm bar Operating temperature Ambient: C Medium Temperature effect temperature (+20 C) Pressure element Movement Dial Pointer Case Window +90 C maximum When temperature of the measuring system deviates from reference max. ±0.4 %/10 K of the span Cu-alloy, C-type Cu-alloy Plastic white, black lettering Plastic, black Stainless steel Plastic, clear (PC) Ingress protection IP 65 per EN / lec 529 Electronics Output signals Supply voltage (Vs) (275 indication angle) V, VS = V DC ma, 2-wire, VS = V DC 5 V DC / V DC Electromagnetic compatibility According to test standards EN / EN
59 GSS The Automatic Gas Source Switch has been developed for devices such as transport incubators, respirators and anaesthesia devices, which can be supplied with gas from a cylinder during transport or whilst stationary connected to a central gas system. Economic and continuous gas supply from the central gas system will be made possible automatically and the safety of patients increased. Art. Nr. Type GSS 0 2 NIST GSS Air NIST Key benefits Increased safety for users and patients Economic gas supply from wall outlet Less frequent replacement of gas cylinders Compact dimensions Simple connection to devices A green pressure indicator indicating gas supply from gas outlet GSS on transport incubator Technical data Gases: Input pressure at gas outlet Input pressure of pressure reducer Output pressure Output flow (no internal reduction) Housing material Dimensions Weight Maintenance Max. life Suitable for use O 2, air, N 2 0 on request 3-6 bar bar = input pressure = input flow Al-alloy, nickel plated 42x65x74 mm approx. 400 g maintenance free 10 years in emergency in transport GSS on transport respirator GSS inlet-hose attachment From gas outlet connection NIST or Afnor From pressure reducer M12 1 (O 2 ) M20 1 (Air) GSS-outlet hose attachment To consumer M15 1 (O 2 ) M17 1 (Air) GSS automatic gas source switch switches automatically between the gas cylinder supply and wall outlet connection. Preference is always given to the more economic wall outlets. As soon as the gas socket is connected, GSS changes over from the wall cylinder to the gas outlet. It does not change over to the gas cylinder unless the pressure at the wall outlet drops below a preset minimum pressure level. Flow scheme DEVICE WALL OUTLET Hoses Art. Nr. Denomination Hose O 2 white 0,5 m SS/M Hose O 2 white 1,5 m SS/NIST Hose O 2 white 0,5 m SS/M
60 Multistar Block with four flowselectors Flowselectors on block Art. Nr. Denomination Multistar Multistar 4 Technical data Calibration pressure Flow Connection 4.5 bar 0-15 litres/minute/flowmeter Oxygen quick coupling SS Block with five flowselectors 58
61 HOSPITAL CENTRAL GAS SUPPLY SYSTEM
62 Hospital Central Gas supply system GAS MANIFOLD MM90 AUTOMATIC The MM90 automatic medical manifold is intended for use in hospital pipeline system as medical gas source. Together with MM90, there shall always be used an alarm providing all alarms according to standard (like gas alarm C44). As 2nd stage is recommended to use a stabilizer. The manifolds covered by this description are designed to allow equal numbers of cylinders to be manifold together to give an operating bank and a reserve bank. The manifold will deliver gas from the operating bank to the manifold pressure regulator until the cylinders are exhausted. At that point the supply will switch to the reserve bank and the exhausted bank can be replenished. The object is to give uninterrupted gas supply. Gas Alarm C44 is standard accessory. The gas alarm C44 gives visual and audible indication. It surveilles and sounds the alarm when the following happens: 1. Change operation side / Leaking on reserve side 2. High operation pressure 3. Low operation pressure The gas alarm C44 is able to communicate with other equipment through relays. The alarm has a battery back-up for 30 minutes of operation. Art. Nr. Denomination Gas Inlet connection Outlet connection MM90 AUTO Manifold O 2 W 21,8 1/14"M G3/4"F+pipe OD 22 mm MM90 AUTO Manifold Air W 21,8 1/14"M G3/4"F+pipe OD 22 mm MM90 AUTO Manifold N 2 O W 21,8 1/14"M G3/4"F+pipe OD 22 mm Specification MM90 includes the following components: MM90 AUTO Manifold Gas alarm C44 Purge valves Plug for close collecting pipeline HP filters For a complete MM90 AUTO manifold add: Collecting pipe set (high pressure valves, and non-return valves /high pressure components/) Cylinder retaining brackets High pressure hoses with safety wire Gas name sign Technical data Capacity at 900 kpa (9 bar) outlet pressure O 2, Air: 90 m 3 /h N 2 O, CO 2 : 50 m 3 /h Max. inlet pressure (settled) 200 bar ( kpa) Max. outlet pressure 12 bar (1200 kpa) Safety + purge valves pipe dimension OD = 10 mm Regulatory status Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System)
63 GAS MANIFOLD MM90 SEMIAUTOMATIC The MM90 semiautomatic medical manifold is intended for use in hospital pipeline system as medical gas source. Together with MM90, there shall always be used an alarm providing all alarms according to standard (like gas alarm C44). As 2nd stage is recommended to use a stabilizer. The manifolds covered by this description are designed to allow equal numbers of cylinders to be manifold together to give an operating bank and a reserve bank. The manifold will deliver gas from the operating bank to the manifold pressure regulator until the cylinders are exhausted. At that point the supply will switch to the reserve bank and the exhausted bank can be replenished.the object is to give uninterrupted gas supply. Gas Alarm C44 is standard accessory. The gas alarm C44 gives visual and audible indication. It surveilles and sounds the alarm when the following happens: 1. Change operation side 2. Leakage on reserve side 3. High operation pressure 4. Low operation pressure. The gas alarm C44 is able to communicate with other equipment through relays. The alarm has a battery back-up for 30 minutes of operation. Art. Nr. Denomination Gas Inlet connection Outlet connection MM90 SEMIAUTO Manifold O 2 W 21,8 1/14"M G3/4"F+pipe OD 22 mm MM90 SEMIAUTO Manifold Air W 21,8 1/14"M G3/4"F+pipe OD 22 mm MM90 SEMIAUTO Manifold N 2 O W 21,8 1/14"M G3/4"F+pipe OD 22 mm * MM90 SEMIAUTO Manifold O 2 /Air W 21,8 1/14"M G3/4"F+pipe OD 22 mm * MM90 SEMIAUTO Manifold N 2 O/CO 2 W 21,8 1/14"M G3/4"F+pipe OD 22 mm *with Gas alarm MC7701, safety valve according to SISHB370 Specification MM90 includes the following components: MM90 SEMIAUTO Manifold Gas alarm C44 Purge valves Plug for close collecting pipeline HP filters For a complete MM90 semiauto manifold add: Collecting pipe set (high pressure valves, and non-return valves /high pressure components/) Cylinder retaining brackets High pressure hoses with safety wire Gas name sign Technical data Capacity at 900 kpa (9 bar) outlet pressure O 2, Air: 90 m 3 /h N 2 O, CO 2 : 50 m 3 /h Max. inlet pressure (settled) 200 bar ( kpa) Max. outlet pressure 12 bar (1200 kpa) Safety + purge valves pipe dimension OD = 10 mm Regulatory status Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System)
64 GAS MANIFOLD MM90 STANBY (BACKUP MANIFOLD) The manifold MM90 STANDBY covered by this description is designed to be used as a third source of suppply in medical central gas systems. The manifold will deliver gas when the nominal supply system pressure falls below a set level (7 bar). This is a back up source. Together with MM90 STANDBY, there shall always be used the MM90 AUTO or SEMIAUTO, alarm providing all alarms according to standard (like gas alarm C44). As 2nd stage is recommended to use a stabilizer. Standard Accessory Gas Alarm C44 The gas alarm C44 gives visual and audible indication. It surveilles and sounds the alarm when the following happens: 1. Too high outlet pressure, 2. Too low outlet pressure, 3. Empty cylinder The gas alarm C44 is able to communicate with other equipment through relays. The alarm has a battery back-up for 30 minutes of operation. Art. Nr. Denomination Gas Inlet connection Outlet connection MM90 STANDBY O 2, Air W 21,8x1/14"M G3/4"F+pipe OD 22 mm MM90 STANDBY N 2 O, CO 2 W 21,8x1/14"M G3/4"F+pipe OD 22 mm Specification MM90 includes the following components: MM90 STANDBY Manifold with pressure switch Purge valves Plug for close collecting pipeline HP filters For a complete MM90 STANDBY manifold add: Gas alarm C44 Collecting pipe set (high pressure valves, and non-return valves /high pressure components/) Cylinder retaining brackets High pressure hoses with safety wire Gas name sign Technical data Capacity at 700 kpa (7 bar) outlet pressure Max. inlet pressure (settled) Max. outlet pressure Safety + purge valves pipe dimension Regulatory status O 2, Air: 90 m 3 /h N 2 O, CO 2 : 50 m 3 /h 200 bar ( kpa) 12 bar (1200 kpa) OD = 10 mm Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System)
65 Gas Manifold MC80 (duplex) This gas manifold is suitable for the medium to the large sized hospital. The MC 80 has a flow capacity of up to 80 m 3 /h and is conveniently designed in modules. The MC 80 reduces the gas pressure in two steps to a constant operating pressure. Service and tests are to be carried out with no disturbance in the supply of gas to the gas distrubution system. The MC 80 (duplex) consists of the three following units: 1. MC 80 - High Pressure Unit This module contains two regulators with safety valves and it is connected to two various cylinder banks with high pressure hoses. When the cylinder bank which has been connected for operation, has been emptied, the other duty side is automatically connected. 2. MC 80 - Stabilizer The stabilizer makes the operating pressure in the distribution system remain constant. The module contains two regulators with safety valves. Since the gas pressure is reduced in two steps the drop in pressure, when changing from the operating cylinder to the other bank of cylinders, is kept to a minimum. The unit is prepared for connection to a liquid supply tank. 3. MC Digital Pressure Monitor This monitor gives visual and audible indication as well as a message in plain language. It electronically surveilles and sounds the alarm when the following happens: 1. Too high or too low distributing pressure, 2. Too high intermediate pressure, 3. Leakage on the reserve gas cylinder bank, 4. When change of operating side has been effected. When connected to a liquid tank the following disturbances will be reported: 1. Too high or too low operating pressure, 2. Too high or too low intermediate pressure, 3. Leakage from the reserves, 4. When change of operating side has been effected. The MC7701 is able to communication with another equipment through a serial link and / or relays. The alarm has a battery back-up for 30 minutes of operation. Specification MC 80 (duplex) includes the following components: MC 80, High Pressure Unit MC 80, Stabilizer MC 7701, Digital Pressure Monitor Evacuating kits for collecting pipe Shut-off valve for the distribution line HP filters For a complete MC 80 (duplex) STANDBY manifold add: Collecting pipe set (high pressure valves, and non-return valves /high pressure components/) Cylinder retaining brackets High pressure hoses with safety wire Gas name sign Art. Nr. Denomination Gas Inlet connection Outlet connection DUPLEX 2 1 O 2 W 21,8 1/14"M 2x G3/4"F+pipe OD 22 mm DUPLEX 2 1 Air W 21,8 1/14"M 2x G3/4"F+pipe OD 22 mm DUPLEX 2 1 N 2 O/CO 2 W 21,8 1/14"M 2x G3/4"F+pipe OD 22 mm MC80 HP 2 1 O 2 W 21,8 1/14"M G3/4"F+pipe OD 22 mm MC80 HP 2 1 Air W 21,8 1/14"M G3/4"F+pipe OD 22 mm MC80HP 2 1 N 2 O/CO 2 W 21,8 1/14"M G3/4"F+pipe OD 22 mm MC80 STAB O 2 3x G3/4"F+pipe OD 22 mm 2x G3/4"F+pipe OD 22 mm MC80 STAB Air 3x G3/4"F+pipe OD 22 mm 2x G3/4"F+pipe OD 22 mm MC80 STAB N 2 O/CO 2 3x G3/4"F+pipe OD 22 mm 2x G3/4"F+pipe OD 22 mm 63
66 Technical data Capacity at 600 kpa (6 bar) working pressure High Pressure Unit MC 80 Stabilizer MC 80 Regulatory status O 2 : 80 m 3 /h N 2 O: 80 m 3 /h Max. inlet pressure: 200 bar ( kpa) Max outlet pressure: 16 bar (1600 kpa) Safety valves OD = 10 mm Purge valves OD =15 mm Max. inlet pressure: 16 bar (1600 kpa) Max working pressure: 8 bar (800 kpa) Safety valves OD = 15 mm Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System)
67 Gas Manifold MC25 The gas cylinder manifold MC 25 is delivered as standard for the gases medical breathing oxygen, nitrous oxide, medical breathing air, medical carbon dioxide, and nitrogen. This manifold has a capacity of 25 m3/h and is primarily intended for small and medium-sized hospitals. The gas cylinder pressure is regulated in two steps. The change-over between operating side and reserve side is made automatically without any differences in the operating pressure. Alarm signal comes from the pressure switches to the alarm unit C44. The alarm signals from the alarm unit C44 can be forwarded directly to a monitoring desk. Function control and service can be carried out without interruption in the gas supply. Specification MC 25 includes the following components: Gas manifold MC 25 Gas alarm C44 (exposed mounting) including power supply Evacuating kits for collecting pipe Shut-off valve for distribution line HP filters For a complete MC 80 (duplex) STANDBY manifold add: High pressure collecting pipes, high pressure valves, filters and non-return valves High pressure hoses with safety wire Cylinder retaining brackets Gas name sign Art. Nr. Denomination Gas Inlet connection Outlet connection MC 25 O 2 W 21,8 1/14"M G1/2"F + pipe OD10mm+OD15mm MC 25 Air W 21,8 1/14"M G1/2"F + pipe OD10mm+OD15mm MC 25 N 2 O, CO 2 W 21,8 1/14"M G1/2"F + pipe OD10mm+OD15mm Technical data Capacity at 5 bar (500 kpa) operation pressure and pressure drop 0.5 bar (50 kpa) Maximum inlet pressure Maximum operation pressure Safety + purge valves pipe dimension Regulatory status O 2, Air, N 2 : 25 m 3 /h N 2 O, CO 2 : 17 m 3 /h 200 bar ( kpa) 10 bar (1000 kpa) OD = 15 mm Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System)
68 high pressure Manifold accessories GCE can supply a complete range of high pressure accessories making it possible to install a medical gas supply system. All accessories are designed and manufactured according to the relevant standard for high pressure systems. The high pressure pipe components are manufactured in the following materials: stainless steel AISI 316 L and brass CuZn39Pb3, and they are tested at 360 bar. Cylinder holders for cylinders and connecting pipes are manufactured in AISI 316. Collection pipe line Collecting pipe set in prepare for GCE HP manifold units. These sets are increasing inlets points for HP cylinders or bundles. Colecting sets are possible connecting serially therefore select ideal combination. Set containts: High Pressure Valve Non Return Valve Collection Pipe Art. Nr. Denomination cylinder collection pipe set cylinders collection pipe set cylinders collection pipe set cylinder collection pipe set cylinders collection pipe set cylinders collection pipe set cylinder collection pipe set+cylinder holders cylinders collection pipe set+cylinder holders cylinders collection pipe set+cylinder holders High Pressure Hoses Medical high pressure hoses are used to connect cylinders or cylinder bundles to gas supply systems. The high pressure hose is intended to be used with a pressure up to maximum 230 bar. Pressure tested at 345 bar. The hose is equipped with a safety wire. Handling The high pressure hose shall be transported, stored, installed and maintained according to Instruction of Use. Maximum life time from installation 5 years. 66 Art. Nr. Gas Lenght (mm) Inlet connection Outlet connection O W21,8 1/14 RH W21,8 1/14 RH O W21,8 1/14 RH W21,8 1/14 RH N 2 O 1250 R3/8 RH W21,8 1/14 RH N 2 O 2000 R3/8 RH W21,8 1/14 RH Air 1250 R5/8 RH W21,8 1/14 RH Air 2000 R5/8 RH W21,8 1/14 RH N 2 /Ar 1250 W24,32 1/14 RH W21,8 1/14 RH N 2 /Ar 2000 W24,32 1/14 RH W21,8 1/14 RH CO W27 2 RH W21,8 1/14 RH CO W27 2 RH W21,8 1/14 RH Technical data - Material Tube Acid-proof Stainless Steel (AISI 316) Plait Stainless Steel (AISI 304) Wire Stainless Steel (AISI 304) Nut and tightening material Acid-proof Stainless Steel (AISI 316) Case and Oetiker Stainless Steel (AISI 304) Regulatory status Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System) Complies with EN ISO (High Pressure Flexible Connection)
69 STABILIZER MM7762 FOR O 2, N 2 O, AIR A stabilizer is a pressure reduction unit with the task to equalize the eventual pressure variation in the hospital pipeline system to ensure a correct pressure from the terminal units. In case of signal for pressure deviation in relation to the alarm settings, the alarm can easily be displayed on a Gas alarm unit. It is also possible to send information to the central operation control. The stabilizer can be delivered with either pressure transmitter 4-20 ma, pressure transmitter 0-50 mv or with contact gauge. The stabilizer makes it possible to distribute gas with different pressure to department and buildings in the hospital area. In some cases it is needed to deliver a higher pressure from the main gas manifold to compensate for small pipe dimensions. In those cases the Stabilizer shall be mounted as close as possible before the first terminal unit, to ensure a correct pressure to the patient. Art. Nr. Denomination Inlet connection Outlet connection MM7762 Stabilizer contact gauge 2x G3/4"F+pipe OD 22 mm 2x G3/4"F+pipe OD 22 mm MM7762 Stabilizer 4-20 ma 2x G3/4"F+pipe OD 22 mm 2x G3/4"F+pipe OD 22 mm Technical data Max inlet pressure 16 bar (1600 kpa) Max operating pressure 10 bar (1000 kpa) Capacity of 500 kpa (5 bar) operating pressure 80 m 3 /h Safety valves pipe dimension OD=15 mm Regulatory status Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System)
70 STABILIZER MC150 FOR O 2, N 2 O, AIR A stabilizer is a pressure reduction unit with the task to equalize the eventual pressure variation in the hospital pipeline system to ensure a correct pressure from the terminal units. In case of signal for pressure deviation in relation to the alarm settings, the alarm can easily be displayed on a Gas alarm unit. It is also possible to send information to the central operation control. The stabilizer can be delivered with either pressure transmitter 4-20 ma, pressure transmitter 0-50 mv or with contact gauge. The stabilizer makes it possible to distribute gas with different pressure to department and buildings in the hospital area. In some cases it is needed to deliver a higher pressure from the main gas manifold to compensate for small pipe dimensions. In those cases the Stabilizer shall be mounted as close as possible before the first terminal unit, to ensure a correct pressure to the patient. Art. Nr. Denomination Inlet connection Outlet connection MC 150 Stabilizer contact gauge 2x G1 1/2"F+pipe OD 35 mm 2x G1 1/2"F+pipe OD 35 mm MC 150 Stabilizer 4-20 ma 2x G1 1/2"F+pipe OD 35 mm 2x G1 1/2"F+pipe OD 35 mm Technical data Max inlet pressure 16 bar (1600 kpa) Max operating pressure 10 bar (1000 kpa) Capacity of 500 kpa (5 bar) operating pressure 150 m 3 /h Safety valves pipe dimension OD=35 mm Regulatory status Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System)
71 GAS MANIFOLD SIMPLEX MMR The Simplex MMR gas manifold is suitable for such health care where the capacity requirement is limited, such as laboratories and small health care clinics Veterinary etc. This gas manifold consists of only one group of cylinders. The regulator is mounted in the collection unit. Each inlet connection has a filter, a non-return valve and a shut-off valve. This arrangement makes it possible to use one cylinder at a time. In order to obtain a stabile outlet pressure this gas manifold is equipped with a preset two-stage regulator. On the high pressure side of the regulator there is a contact gauge the signal of which can be carried further to an alarm unit. Simplex MMR is delivered mounted and test-pressurized. Specification Simplex MMR iincludes the following components: Gas cylinder manifold Simplex MMR Collecting pipe Manyflow block for three hoses Gas evacuation kits for collecting pipe For a complete Simplex MMR add: Gas alarm C44 High pressure hoses with safety wire Cylinder retaining brackets Gas name signs Art. Nr. Denomination Gas Inlet connection Outlet connection Simplex MMR O 2, Air, N 2, Ar W 21,8 1/14"M G3/8"M Simplex MMR N 2 O, CO 2 W 21,8 1/14"M G3/8"M Technical data Capacity at working pressure 5 bar Max. inlet pressure Max. outlet pressure Regulatory status O 2, Air: 30 m 3 /h N 2 O, CO 2 : 25 m 3 /h 200 bar (20000 kpa) 5 bar (500 kpa) Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System) 340 Safety Valves: See accessories central gas
72 Medical Shut-off Valves To meet safety requirements, the gas supply to operating rooms etc must be fitted with a device to allow instant shut off. To allow maintenance the gas supply must be controlled by section. To achieve the demands of safety and maintenance, shut-off valves should be fitted in every main line, riser and branch line in the pipework system. The valves are degreased and blown clean. They can be equipped with unions to be soldered to the copper piping and they are provided with name labels in Swedish, Norwegian, Danish, Finnish, and Hungarian for each gas type. Before delivery each valve is individually leak tested. The ball is sealed with washer of PTFE. The stem is sealed with two silicon O-rings and PTFE on washer. The housing valves are sealed with an EPDM quality O-ring. Shut-off valves for oxygen, air for breathing, nitrous oxide and all other medical gases. The shut-off valves are of the ball type with a straight cylindrical bore. Easy to operate - 90 turn between fully open and fully closed. No maintenance - the ball valve does not need services, when necessary the whole valve is exchanged. Unions for brazing and flat sealing connections. Reliable, easy to fit. GCE max. 40 bar L H Shut-off valve incl 2 pcs washer Art. Nr. Conn. thread Valve L (mm) H(mm) ISO-G 1/2 DN ISO-G 3/4 DN ISO-G 1 DN ISO-G 1 1/4 DN ISO-G 1 1/2 DN ISO-G 2 DN connection parts (2 connection nuts and 2 connectione piecs) Art. Nr. Material Valve Pipe dim. inside / outside conn. *) Red brass SS 5204 DN / 15*) Red brass SS 5204 DN Red brass SS 5204 DN / 22*) Red brass SS 5204 DN Red brass SS 5204 DN / 28 *) Red brass SS 5204 DN / 35 *) Red brass SS 5204 DN Red brass SS 5204 DN 32 35/42 *) Red brass SS 5204 DN connection parts (soldering adapter dn40-dn50) Art. Nr. Material Valve Pipe dim. inside / outside conn Red brass SS 5204 DN 50 48/54 Order both DN 40 and DN 50 for union enlargement. Spare parts Art. Nr. Denomination Valve Thread P Labelsheet DN 10, 15, 25, 32, P Washer, 1 pce DN P Washer, 10 pcs DN P Washer, 1 pce DN P Washer, 10 pcs DN P O-ring, EPDM, 5 pcs DN P O-ring, EPDM, 5 pcs DN Connection nut, 2 pcs DN 10 ISO-G 1/ Connection nut, 2 pcs DN 15 ISO-G 3/ P Connection nut, 2 pcs DN 20 ISO-G Connection nut, 2 pcs DN 25 ISO-G 1 1/ P Connection nut, 1 pce DN 40 ISO-G 2 Technical data Material valve housing: Ball: Stem: Max working pressure: Tighten proof: Regulatory status Nickel plated brass Chrome plated brass Nickel plated brass 33 bar (3300 kpa) 50 bar (5000 kpa) Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System) 70
73 Non Return Valve The non return valve unit is intended for use in medical central gas systems to secure that gas doesn t flow back from the equipment and pipes through the central gas system. This is very important for example when technical air is taken from medical air pipes for use in laboratories. The non return valve unit consists of a non return valve (NRV) with flow direction arrow, lockable medical shut off valves, soldering pieces, nuts and a gasspecific medical quick coupling (QC) for medical breathing air. This design makes the NRV very easy to test. The QC can also be used for checking the pressure, doing leak tests and take gas samples. The NRV unit can also be delivered with QC for instrumental air. Contact the manufacturer for more information. Non return valve unit Art. Nr. Denomination Total Length Non return valve unit medical breathing air DN mm Non return valve unit medical breathing air DN mm Non return valve unit medical breathing air DN mm Sealing between non return valve and connecting piece Art.Nr. Denomination P DN15 O-ring, 10 pcs P DN25 Sealing, 10 pcs P DN40 O-ring, 10 pcs Technical data Opening pressure Pressure class Regulatory status 0.06 bar (6 kpa) PN16 Degreesing for Oxygen use no CE-marking 71
74 Emergency Shut-Off Valve Box DN15 For safety and service reasons a central gas system must be equipped with shut-off valves placed so that the gas supply can easily be interrupted. The valves are mounted in a box. The emergency shut-off valve boxes shall be placed so that the gas can be shut off section wise. This means that the boxes should be placed before each ward, operating unit, part of ward for critical treatment and individual surgeries. The emergency shut-off valve box is delivered with connection tubes and each box has been test pressurized and controlled for tightness. The emergency shut-off valve has large ergonomical handles. If mounted in a recessed way, the emergency shut-off valve box fits walls with 70 mm beam. With a 90 mm beam there is extra space (23,5 mm) behind the valve box usable for e.g. fire isolation. All models, also with four or five gases, fit between the beams in a CC-60 wall. The box is gas-tight which prevents gas accumulation inside the wall. The product is CE-marked according to EN ISO and current SIS HB 370. It is important that the boxes are placed so that they are easily available for authorized personnel. The front door shall be sealed. In order to avoid mistakes the boxes shall be clearly and distinctly marked with gas sort. A sign showing which section the box serves must be placed in its immediate vicinity. The valves are open when the handles are in vertical position in line with the printed marking on the plate. Shut-off valve box DN15 Art. Nr. Type Inlet pipe Outlet pipe valve DN 15 ø 15 ø valves DN 15 ø 15 ø valves DN 15 ø 15 ø valves DN 15 ø 15 ø valves DN 15 ø 15 ø VALVE BOX FROM ABOVE EXPOSED MOUNTING SEEN FROM SIDE RECESSED MOUNTING SEEN FROM SIDE 4-5 VALVE BOX FOM ABOVE 72
75 Emergency Shut-Off Valve Box DN20 Shut-off valve box DN20 Art. Nr. Type Inlet pipe Outlet pipe valves DN 20 ø 22 ø valves DN 20 ø 22 ø 22 Technical data Gases Number of gases Working pressure Tube dimension Material Weight Regulatory status O 2 ; N 2 O; AIR;Air-800(I-Air); CO 2 ; N 2 ; VAC (all medical gases) (ø15 1) 1 to 5 valves (DN15) (ø22 1) 1 to 3 valves (DN20) 10 bar ø15 1 mm; ø22 1 mm Brass; Copper 4-15 kg Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System) 2-3 VALVE BOX FROM ABOVE EXPOSED MOUNTING SEEN FROM SIDE RECESSED MOUNTING SEEN FROM SIDE 73
76 Pressure Watch with gauge, alarm and quick coupling DN15 A Pressure Watch can be used in wards where there is no a need for the slave regulator of a Pressure Monitor. The Pressure Watch has the same shut off function as an ordinary Emergency Shut-Off Valve Box. Behind the plexiglass you find quick couplings that are used to connect spare cylinders and gauges. To inform the hospital staff regarding gas failures the Pressure Watch is equipped with sensors for one of the following alarm systems; 1) pressure switches that you connect to Gas alarm C44, 2) pressure transmitters that you connect to Gasalarm MC7701 or 3) pressure transmitters 4-20 ma that you connect directly to the hospital central computer system. Alarm system 1 is the most commonly used. The Pressure Watch is delivered with 300 mm connection tubes and each box has been test pressurized and controlled for tightness. The Pressure Watch has large ergonomical handles. If mounted in a recessed way, the emergency shut-off valve box fits walls with 70 mm beam. With a 90 mm beam there is extra space (23,5 mm) behind the valve box usable for e.g. fire isolation. All models, also with four or five gases, fit between the beams in a CC-60 wall. The box is gas-tight which prevents gas accumulation inside the wall. The product is CE-marked according to EN ISO and present SIS HB 370. It is important that the boxes are placed so that they are easily available for authorized personnel. The front door shall be sealed. In order to avoid mistakes the boxes shall be clearly and distinctly marked with gas sort. A sign showing which section the box serves must be placed in its immediate vicinity. The valves are open when the handles are in vertical position in line with the printed marking on the plate. To close the valves you turn the handle 90 degrees clockwise. pressure watch dn15 with pressure switches Art. Nr. No. of valves Gas Inlet/Outlet pipe mm DN O 2 ø O 2, Air ø O 2, N 2 O, Air ø O 2, N 2 O, Air, Air-800 ø O 2, N 2 O, Air, Air-800, CO 2 ø O 2, Air, VAC ø15 pressure watch dn15 With transmitter 4-20 ma Art. Nr. No. of valves Gas Inlet/Outlet pipe mm DN O 2 ø O 2, Air ø O 2, N 2 O, Air ø O 2, N 2 O, Air, Air-800 ø O 2, N 2 O, Air, Air-800, CO 2 ø VALVE BOX FROM ABOVE EXPOSED MOUNTING SEEN FROM SIDE RECESSED MOUNTING SEEN FROM SIDE 4-5 VALVE BOX FOM ABOVE 74
77 Pressure Watch with gauge, alarm and quick coupling DN20 pressure watch dn20 with pressure switches Art. Nr. No. of valves Gas Inlet/Outlet pipe mm O 2, Air ø O 2, N 2 O, Air ø O 2, Air, Air-800 ø O 2, Air, VAC ø22 PRESSURE WATCH DN20 With transmitter 4-20 ma Art. Nr. No. of valves Gas Inlet/Outlet pipe mm O 2, Air ø O 2, N 2 O, Air ø O 2, Air, Air-800 ø O 2, Air, VAC ø22 pressure watch DN20 emergency source with pressure switches Art. Nr. No. of valves Gas Inlet/Outlet pipe mm O 2, Air ø O 2, N 2 O, Air ø O 2, Air ø O 2, Air, VAC ø22 pressure watch DN20 emergency source with transmitter 4-20 ma Art. Nr. No. of valves Gas Inlet/Outlet pipe mm O 2, Air ø O 2, N 2 O, Air ø O 2, Air, Air-800 ø O 2, Air, VAC ø22 Technical data Gases Number of gases Working pressure Tube dimension Emergency QC inlets Pressure gauges Pressure sensors Material Weight Regulatory status O 2 ; N 2 O; Air; AIR-800 (I-Air); CO 2 ; N 2 ; VAC (all medical gases) (ø15 1) 1 to 5 valves (DN15); (ø22 1) 1 to 3 valves (DN20) 10 bar (PN16) ø15 1 mm; ø22 1 mm QC by national standards 0-16 bar Pressure switches; Transmitters 0-50 mv (special order); 4-20 ma Brass; Copper 4-15 kg Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System) VALVE BOX FOM ABOVE EXPOSED MOUNTING WITHOUT EMERGENCY SOURCE SEEN FROM SIDE RECESSED MOUNTING WITH EMERGENCY SOURCE SEEN FROM SIDE 75
78 Pressure monitor DN15 The pressure monitor makes sure that the lower operating pressure for nitrous oxide compared to oxygen is kept. When the spare supply is used to keep the gas division going, the pressure monitor will supervise the operating pressures to make sure that these are within the established standards. Furthermore, an optic and acoustic signal to a manned area will be obtained. The pressure monitor is equipped with a digital pressure reading unit (MC 7701). The surveillance is done by pressure transmitters. The following gases are under surveillance: breathing oxygen, nitrous oxide, and instrument air. Alarm is indicated by an acoustic and and visual signal at the same time as the exact cause of the alarm is written on the display. This happens if the gas pressure rises above or sinks below the set maximum or minimum limits respectively. The pressure monitor is also equipped with bayonet coupling for breathing oxygen, nitrous oxide, breathing air, and instrument air. When necessary, it is possible to connect spare gas to these. Art. Nr. Denomination For 2 gases O 2, Air For 3 gases O 2, N 2 O, Air For 4 gases O 2, N 2 O, Air, Air-800 Technical data Capacity emergency supply at 500 kpa (5 bar) and pressure drop 0,5 bar Capacity normal supply at 500 kpa (5 bar) and pressure drop 0,5 bar Max. inlet pressure Group regulator capacity at inlet pressure 3 bar Mounting measurements (outside dimensions) DN15 Pressure monitor Regulatory status approx 380 litres/min approx 780 litres/min 1000 kpa (10 bar) 150 l/min Width 549 mm Height 633 mm Depth 128 mm Width 555 mm Height 689 mm Mounting depth max 138 mm Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System) Pressure drop test. Inlet pressure 5 bar Pressure drop test. Inlet pressure 5 bar. Emergency QC inlets. 76
79 GAS ALARM C44 SYSTEM Gas Alarm C44 is a gas pressure alarm intended for small gas manifolds, stabilizers and for example pressure gauges/pressure switches connected directly to the main line. The C44 is a microprocessor based alarm for 4 alarm channels and is connected to the pressure sensing device with volt free contacts, for example pressure gauges or pressure switches. Alarm C44 is voltage fed with 12 VAC. Supply voltage is fed by the enclosed transformer. Visible from the front is an integrated push button TEST/MUTE. If there is no alarm condition, all the light emitting diodes and the buzzer can be tested when the button is pushed. Should there be an alarm condition, the signal will be suppressed for 15 minutes. If an alarm has been silenced and a new one occurs, the MUTE function is cleared and the signal comes back until the cause has been attended to and the MUTE button is pushed again. Alarm C44 is equipped with an environmental-friendly rechargeable NiMH back-up battery. The sound volume is adjustable via a potentiometer placed behind the cover. At delivery the sound volume is set at Medium. Art. Nr. Denomination P Gas alarm C44 recessed mounting P Gas alarm C44 exposed mounting 1 sheet plastic strips for inserting will be delivered with the Alarm C44. Cut out the plastic strips, loosen the cover lid and insert the respective plastic strip into the correct pocket. Please note: All electronics is subjected to static electricity. Therefore, when working with Alarm C44 grounded wristbands should be used. Technical data Transformer ~ 11,5V, 0.9 A Battery Pack 9 V Power Consumption about 300 ma Weight 1 kg Working temperature 0-60 ºC Relay outputs 4 Relay supply voltage 4 V Breaking current 1A, 30 W Dimension exposed mounting L H D Dimension recessed mounting L H D Recommended cable Signal cable 0.25 mm 2 Feed cable 0.75 mm 2 Maximum cable lenght 3 m (alarm-pressure switchs) Regulatory status Complies with Medical Devices Directive 93/42/EEC Complies with EN ISO (Central Gas Supply System) EMC tested in accordance EN (Emission and immunity) Exposed mounting Recessed mounting Note! Measurements in mm. 77
80 GAS ALARM MC7701 This monitor gives visual and audible indications as well as status messages in plain language. When used with a manifold, the follows conditions are surveilled. 1. Too high or too low operating pressure, 2. Too high distribution pressure, 3. Leakage on the non-operating gas cylinder bank, 4. When change of operating side has been effected. When connected to a liquid tank the following disturbances will be reported: 1. Too high or too low operating pressure, 2. Too high or too low distribution pressure, 3. Leakage on the non operating gas cylinder bank. 4. When change of operating side has been effected. When used with a pressure watch the following conditions are surveilled: Too high or too low operating pressure. The MC7701 is able to communication wtih another equipment through a serial link RS485, Modbus RTO and / or relays. The alarm has a battery back-up for 30 minutes of operation. Art. Nr P Denomination Digital pressure monitor MC7701 UNILARM accessories P Cable with Hirsman contact 3m P Cable with cable conecting piece 3 m Backup batteries MC P Pressure Transmitter 0-50 mv G1/ bar P Pressure Transmitter 0-50 mv G1/ bar P Pressure Transmitter 0-50 mv G1/ bar Technical data Transformer ~ 24V, 1.3 A Battery Pack NiMH 10,8 V Power Consumption 15 W Enclosure IP65 Weight 2kg Working temperature 0-60 ºC Relay outputs 14st Serial communication Modbus RTU Dimension L H D Dim. including fastening plate L H D Display languages Swedish, Norwegian, Danish, Finnish, English and Hungarian Regulatory status Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System) EMC tested in accordance EN (Emission and immunity)
81 Gas alarm G4 The alarms are summation alarms for both high and low pressure. In addition to this, a failure in the computer communication system, or a damaged signal cable (for example: cut off) is also indicated. The loudness of the sound can be adjusted by using the potentiometer placed behind the covering lid. At delivery the sound is set at medium. The gas alarm G4 is available in two different designs, for recessed mounting and for exposed mounting. The display will show any of eight languages chosen from stickers enclosed. The alarm is equipped with a rechargeable NiCa battery in case of power failure. Art. Nr. Denomination Gas alarm G4 recessed mounting Gas alarm G4 exposed mounting Technical data To be used only together with digital Pressure Monitor MC 7701 At the most, 10 units of gas alarm 4 can be connected in a series Battery Pack 9 V Weight 1 kg Working temperature 0-60 ºC Power supplied from MC 7701 Dimension exposed mounting L H D Dimension recessed mounting L H D Recommended cable: Signal cable 0.75 mm 2 Computer wire like Alpha type 5472C or similar Maximum cable lenght: 400 m (between alarms) Regulatory status Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Central Gas Supply System) EMC tested in accordance EN (Emission and immunity) Exposed mounting Recessed mounting Note! Measurements in mm. 79
82 Gas Outlet MC70 (terminal unit) GCE gas outlets type MC 70 generation are self-sealing, i.e. they close automatically when a connected apparatus is removed. The gas outlets are furnished with a quick connection valve which means that the desired apparatus can be connected or disconnected by means of a simple one-step motion. The MC 70 gas outlets may be recessed in the wall or mounted in a panel. All MC 70 gas outlets have the same design but different colour codings and labels for different gases and of course gas specific non-interchangeable quick connection valves. Special efforts have been made to make the maintenance of the gas outlets as easy as possible. No special tools Maintenance valve of ball-type Few components Furthermore the MC 70 are made according to standard SS EN for quick connections and international standard SS EN ISO for terminal units. This means that the gas components are non-interchangeable in every maintenance connection point. The gas outlet is delivered with separate packages for quick connection valve, valvebody, plastic cover with name plate, push-release plate etc. To make installation easier, the valve body has a tightening plug mounted for convenient pressure testing. All necessary mounting details such as brackets, screws etc. are included in the packages. Detailed instructions are also part of the delivery. When mounting the gas outlet in a recessed way the gas outlet can be mounted either in the front wall or in the rear wall, depending on which is first set up. Recessed and exposed instalation set is necessary orded separately. Gas outlet Art. Nr. Denomination Label denomination Compl. for O 2 O 2 - white Compl. for N 2 O N 2 O - blue Compl. for Air Air - black/white Compl. for VAC VAC - yellow Compl. for AGSS AGSS - purple Compl. for Air-800 (I-Air) Air black/white Compl. for N 2 N 2 - black Compl. for CO 2 CO 2 - grey For recessed mounting add Art. Nr. Denomination Recessed installation set For exposed mounting add Art. Nr. Denomination Exposed installation set Technical data Maximum working pressure 10 bar Tube dimension diameter 8 mm Pressure class PN 16 Regulatory status Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO (Terminal units standard) Complies with EN ISO (Terminal units AGSS) Complies with SS EN (Type standard) labels M70 Art. Nr A A A A A A A A A A A26810 Denomination Circular Label O 2 White 85/55 TU SS Circular Label N 2 O Blue 85/55 TU SS Circular Label Air Black/White 85/55 TU SS Circular Labe Air-800 (I-Air) Black/White 85/55 TU SS Circular Label VAC Red 85/55 TU SS Circular Label VAC Yellow 85/55 TU SS Circular Label GASUTLOPP Blue/Brown 85/55 TU SS Circular Label GASUDLØB Blue/Brown 85/55 TU SS Circular Label GASSUTLØP Blue/Brown 85/55 TU SS Circular Label KAASUJEN POISTO Blue/Brown 85/55 TU SS Circular Label AGSS Purple 85/55 TU SS 80
83 Accessories and Others Safety valve medical pipeline systems The safety valve is used in medical pipeline systems to secure that the pressure does not exceed 6,8 bar. The safety valve shall be mounted on outgoing pipelines on Simplex MMR or can be mounted on other pipelines. Bracket for wall mounting Safety Valve Tube Mounting Art. Nr. Gas Relief Inlet connection Outlet connection Pressure Medical gases and air 6,8 bar G 3/4 F G 3/4 F Safety Valve Simplex MMR Mounting Art. Nr. Gas Relief Inlet connection Outlet connection Pressure Medical gases and air 6,8 bar G 3/8 F G 3/4 F Technical data Evacutaion flow 130 m 3 /h Evacutaion outlet pipe Ø 15 mm Relief pressure 6,8 bar Material Brass, copper, stainless steel, rubber Pressure class PN16 Regulatory status Degreesing for Oxygen use no CE-marking 81
84 Pressure Transmitter Measurements Connection Small compact pressure transmitter with god performance. Suitable for mobile applications when vibration reliable sensors are needed. Compact connectors. Max. deviation 1,0% For relative pressure Pressure range from 0...0,25 bar to bar Degreased for Oxygen Art. Nr. Denomination Pressure Thread Cable P Pressure transmitter 0-16 bar G1/4 1 m P Pressure transmitter 0-25 bar G1/4 1 m P Pressure transmitter bar G1/4 1 m Technical data Performance Pressure range 16 bar Piezoresistive sensor Pressure range 25 bar hin film-sensor Max. deviation 1,0% of end value according to DIN ,5% BFSL) Liniarity and hysteresis Included in above Repeat accurasy ±0,05% of end value Long term ±0,2% of end value per annum Overpressure sensitivity 16 bar 3,5x; 600 bar 2x; >600 bar 1,5x Underpressure sensitivity Insensitive for vacuum Response time 1 ms för 10-90% of range Pressure connection G1/4 External thread Sensor body Acid-proof stainless steel SIS2350 Parts in connection with the medium Acid-proof stainless steel SIS2350 Mediun temperature -30 C till +100 C Surrounding temperature -30 C till +85 C Temperature deviation ±0,3% of measure range/10k for zero and measure range Temp.compensated range 0 C till +80 C Signal alternative 4-20 ma, 0-10V Supply Voltage Signal 4-20 ma 10-30V DC Signal 0-10V 14-30V DC Max. permitted load for: RA[Ω]=UB[V]-10V signal 4-20 ma 0,02A Max. permitted load for: RA>10kΩ signal 0-10V Elektrcal connection Contact Hirschmann-Mini G4a1MMT Polarity reversal safe, short circuit and overload protected Adjustability Not adjustable Protective class IP65 acc. to EN 60529/IEC529 EMC-data Emmision EN Immunity EN Weight 0,10 kg 2-wire ma 3-wire V DC Supply voltage UB+ 1 1 Supply voltage OV- 2 2 Signal S+ 3 Signal S- 2 82
85 HIGH PRESSURE components GCE can supply a wide range of components making it possible to install a medical gas supply system. All components are designed and manufactured according to the relevant standard for high pressure systems. The high pressure pipe components are manufactured in the following materials: stainless steel AISI 316 L and brass CuZn39Pb3, and they are tested at 360 bar. Retaining brackets for cylinders and connecting pipes are manufactured in AISI 306. Connecting pipes for cylinder manifolds Connecting pipes with retaining brackets of stainless steel, for 1-4 cylinders. Art. Nr. Connecting threads Length (mm) Number of cylinders W 21,8 1/14"RH EXT-INT W 21,8 1/14"RH EXT-INT W 21,8 1/14"RH EXT-INT Cylinder retaining brackets Cylinder retaining brackets, completely made of stainless steel, for 1 or 2 cylinders. Art. Nr. Length (mm) Number of cylinders P P Connection pipes for cylinder pack manifolds Art. Nr. Connecting threads Length (mm) Number of cylinders W 21,8 1/14"RH EXT-INT W 21,8 1/14"RH EXT-INT W 21,8 1/14"RH EXT-INT Extension pipes Art. Nr. Connecting threads Length (mm) W 21,8 1/14"RH EXT-INT
86 Connecting components for cylinder manifolds Art. Nr. Description Thread Position Connection pipe 90 o W 21,8 1/ Blind plug W 21,8 1/ Adaptor W 21,8 1/14 male LH/ female RH P Coupling nut W 21,8 1/14 LH/RH End plug with nut W 21,8 1/ T-pipe for DUPLEX W 21,8 1/ S-pipe W21,8 1/ Aluminium washer 50 pcs 16/ mm P Copper washers 10 pcs 18/12,7 1.5 mm Non-return valves for connection pipes Art. Nr. Denomination Non-return valve for connection pipes High pressure filter Art. Nr. Denomination High pressure filter HIGH PRESSURE VALVES 300 bar Art. Nr. Inlet Outlet W 21,8 1/14"RH W 21,8 1/14"LH HIGH PRESSURE VALVES 200 bar Art. Nr. Inlet Outlet W 21,8 1/14"RH W 21,8 1/14"LH 84
87 gas signs LAMINATED LABELS Art. Nr. Label description Country Dimensions ANDNINGSOXYGEN SE mm MEDISINSK OKSYGEN NO mm MEDICINSK OXYGEN DK mm HAPPI FI mm LUSTGAS SE mm MEDISINSK LYSTGASS NO mm DINITROGENOXID DK mm DITYPPIOKSIDI FI mm MEDICINSK LUFT SE mm MEDISINSK LUFT NO mm AIR DK mm ILMA FI mm MEDICINSK KOLDIOXID SE mm MEDISINSK KARBONDIOKSID NO mm MEDICINSK KULDIOXID DK mm CO 2 FI mm 85
88 REGULATORS AND FLOW METERS FOR MEDICAL GASES IMPORTANT INFORMATION AND RECOMMENDATIONS Our products are reliable and accurate instruments made in compliance with strict international standards and, if used and maintained according to the instructions provided in the information leaflet, they require no special servicing and repairs, except the following: 1. Replacement of a gasket on the inlet connection - to be performed every six to eight months by the user. Use only gaskets supplied by the manufacturer or supplier of the regulator as they are made of a special non-combustible material. 2. Functional and performance check of the product - to be performed once a year by the manufacturer or by an authorized servicing company. 3. Product inspection - to be performed every five to six years after the manufacturing date by the manufacturer or by an authorized servicing company. The inspection consists in a replacement of rubber parts of the product and its functional check. 4. Repairs - in case of any defects or damage the product shall be delivered to the manufacturer or to an authorized servicing company to be professionally repaired. The maximum service life of the regulator is ten years from the manufacturing date. The manufacturing date is marked on each product as a part of the serial number. Example for products made by the beginning of 1999: Serial number year manufacture ordinal number month of manufacture - January Example for products made during 2000: Serial number year manufacture ordinal number month of manufacture - June SAFETY INSTRUCTIONS The objective of the company GCE is not only customer satisfaction with reliable products but also safe operation of all equipment associated with medicinal gases. Therefore is it necessary to observe all instructions for the use and, particularly, the following safety principles: 1. Concentrated oxygen shall not come into contact with oils, grease and impurities to prevent its self-ignition. 2. Pressure cylinders shall be always secured against fall, exposure to heat and manipulation by unauthorized person. 3. Smoking and open fire manipulations are strictly prohibited in the proximity of pressure cylinders or gas equipment. 4. Personnel working with classified gas equipment shall be properly trained. 5. Any servicing of regulators, flow meters, combined valves and concentrators shall be requested only from specialist servicing organizations. CERTIFICATION GCE has introduced and certified its quality management system according to IS013485:2003 for medical devices. The products meet the requirements of the EU Directive 93/42/EEA and they are certified and provided with the CE mark. Any requirements for other technical parameters shall be discussed with the manufacturer. 86
89 CERTIFICATES DNV BUSINESS ASSURANCE MANAGEMENT SYSTEM CERTIFICATE Certificate No AQ-CZS-NA DNV BUSINESS ASSURANCE MANAGEMENT SYSTEM CERTIFICATE Certificate No AQ-CZS-NA This is to certify that the Management System of: GCE Holding AB This is to certify that the Management System of: GCE Holding AB Källvattengatan, SE , Malmö, Sweden Källvattengatan 9, SE , Malmö, Sweden has been found to conform to the standard: ISO 9001:2008 This Certificate is valid for the following product or service ranges: has been found to conform to the standard: ISO 13485:2003 This Certificate is valid for the following product or service ranges: Design, production, sales and servicing of equipment for using of technical gases in industry. Pressure regulators, closing, combined and special valves, cutting, welding, heating and brazing torches, safety equipment, speciality torches, fittings, accessories for industrial purposes. Design, production, sales and servicing of medical devices for using of medical gases in health service. Pressure regulators, terminal units, suction equipment, medical hoses, cylinder and combi valves and flow meters for medical gases. Initial Certification date: 28 February 1997 This Certificate is valid until: 28 February 2015 Place and date: Høvik, 28 February 2012 for the Accredited Unit: DET NORSKE VERITAS CERTIFICATION AS, NORWAY Initial Certification date: 28 February 1997 This Certificate is valid until: 28 February 2015 Place and date: Høvik, 28 February 2012 for the Accredited Unit: DET NORSKE VERITAS CERTIFICATION AS, NORWAY The audit has been performed under the supervision of Evangelos Tavandžis Lead Auditor MSYS 002 Bjørg Synnøve Nesgård Management Representative The audit has been performed under the supervision of Evangelos Tavandžis Lead Auditor MSYS 002 Bjørg Synnøve Nesgård Management Representative Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid. This Certificate has been digitally signed. See for more info HEAD OFFICE. Det Norske Veritas AS, Veritasveien 1, 1322 Hovik, Norway. Tel: Fax: Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid. This Certificate has been digitally signed. See for more info HEAD OFFICE. Det Norske Veritas AS, Veritasveien 1, 1322 Hovik, Norway. Tel: Fax:
90 General business terms and conditions Preamble 1. These General Conditions shall apply when the parties agree in writing or otherwise thereto. Deviations from the Conditions shall not apply unless agreed in writing. When used in these conditions the term written or in writing refers to a document signed by both parties or a letter, fax, electronic mail or other means agreed by the parties. Product Information 2. Data in product information and price lists are binding only to the extent that they are expressly referred to in the contract. Technical Documents and Technical Information 3. All drawings and other technical documents regarding the goods or their manufacture submitted by one party to the other, prior or subsequent to the formation of the contract, shall remain the property of the submitting party. Drawings, technical documents or other technical information received by one party shall not, without the consent of the other party, be used for any other purpose than that for which they were submitted. They may not without the consent of the other party be copied, reproduced, transmitted or otherwise communicated to a third party. 4. The Seller shall, not later than by delivery of the goods, free of charge provide the Buyer with one copy, or the larger number of copies that may have been agreed, of drawings and other technical documents, which are sufficiently detailed to permit the Buyer to carry out installation, commissioning, operation and maintenance (including running repairs) of all parts of the goods. The Seller shall not, however, be obliged to supply manufacturing drawings of the goods or spare parts. Delivery Test 5. Where a delivery test has been agreed, it shall, unless otherwise agreed, be carried out where the goods are manufactured. If technical requirements for the test have not been agreed, the test shall be carried out in accordance with general practice in the industry concerned in the country where the goods are manufactured. 6. The Seller shall notify the Buyer in writing of the delivery test in sufficient time to permit the Buyer to be present at the test. If the Buyer has received such notice, the test may be carried out even if the Buyer is not represented at the test. The Seller shall record the test. The test report shall be sent to the Buyer. The report shall, unless otherwise shown by the Buyer, be considered to correctly describe the execution of the test and its results. 7. If at the delivery test the goods are found not to be in accordance with the contract, the Seller shall as soon as possible ensure that the goods comply with the contract. If so required by the Buyer a new test shall thereafter be carried out. The Buyer may not, however, require a new test if the defect was insignificant. 8. If no other division of the costs has been agreed, the Seller shall bear all costs for delivery tests carried out where the goods are manufactured. The Buyer shall, however, at such delivery tests bear all costs for his representatives, including costs for travel and subsistence. Delivery 9. Where a trade term has been agreed, it shall be interpreted in accordance with the INCOTERMS in force at the formation of the contract. If no trade term is specifically agreed, the delivery shall be Ex Works. Time for Delivery. Delay 10. If, instead of a fixed date for delivery, the parties have agreed on a period of time within which delivery shall take place, such period shall start to run at the formation of the contract. 11. If the Seller finds that he will not be able to deliver the goods at the agreed time or if delay on his part seems likely, he shall without undue delay notify the Buyer thereof in writing, stating the reason for the delay and if possible the time when delivery can be expected. If the Seller fails to give such notice, he shall, regardless of the provisions of Clauses 13 and 14, reimburse the Buyer for any additional expenses, which the latter incurs and which he would have avoided, had he received notice in time. 12. If delay in delivery is caused by a circumstance which under Clause 36 constitutes ground for relief or by an act or omission on the part of the Buyer, including suspension by the Seller under Clause 18, the time for delivery shall be extended by a period, which is reasonable having regard to the circumstances in the case. The time for delivery shall be extended even if the reason for delay occurs after the originally agreed time for delivery. 13. If the Seller fails to deliver the goods on time, the Buyer is entitled to liquidated damages from the date on which delivery should have taken place. The liquidated damages shall be payable at a rate of 0.5 per cent of the agreed price for each complete week of delay. If the delay concerns only a part of the goods, the liquidated damages shall be calculated on the part of the price which is properly attributable to the part of the goods which cannot be taken in use due to the delay. The liquidated damages shall not exceed 7.5 per cent of that part of the price on which it is calculated. The liquidated damages become due at the Buyer s written demand but not before all of the goods have been delivered or the contract is terminated under Clause 14. The Buyer loses his right to liquidated damages if he has not lodged a written claim for such damages within six months after the time when delivery should have taken place. 14. If the Buyer is entitled to maximum liquidated damages under Clause 13, and the goods are still not delivered, the Buyer may in writing demand delivery within a final reasonable period which shall not be less than one week. If the Seller fails to deliver within such final period and this is not due to any circumstance for which the Buyer is responsible, the Buyer may, by written notice to the Seller, terminate the contract in respect of that part of the goods which cannot be taken in use due to the delay. In case of such termination the Buyer shall also be entitled to compensation for the loss he suffers because of the Seller s delay to the extent that the loss exceeds the maximum of liquidated damages which the Buyer may claim under Clause 13. This compensation shall not exceed 7.5 per cent of that part of the price which is properly attributable to the part of the goods in respect of which the contract is terminated. The Buyer shall also have the right to terminate the contract by written notice to the Seller if it is clear that there will be a delay, which under Clause 13 would entitle the Buyer to maximum liquidated damages. In case of termination on this ground the Buyer shall be entitled to both maximum liquidated damages and compensation under the third paragraph of this Clause. Except for liquidated damages under Clause 13 and termination of the contract with limited compensation under this Clause 14, all other claims in respect of the Seller s delay shall be excluded. This limitation of the Seller s liability shall not apply, however, where the Seller has been guilty of gross negligence. 15. If the Buyer finds that he will be unable to accept delivery of the goods on the agreed date, or if delay on his part seems likely, he shall without undue delay notify the Seller thereof in writing stating the reason for the delay and, if possible, the time when he will be able to accept delivery. If the Buyer fails to accept delivery on the agreed date, he shall nevertheless make any payment which is dependent on delivery as if the goods in question had been delivered. The Seller shall arrange storage of the goods at the Buyer s risk and expense. If the Buyer so requires, the Seller shall insure the goods at the Buyer s expense. 16. Unless the Buyer s failure to accept delivery as referred to in Clause 15 is due to any such circumstance as described in Clause 36, the Seller may by written notice require the Buyer to accept delivery within a reasonable period. If, for any reason for which the Seller is not responsible, the Buyer fails to accept delivery within such period, the Seller may, by written notice to the Buyer, terminate the contract in respect of that part of the goods which is ready for delivery but has not been delivered due to the Buyer s default. The Seller shall then be entitled to compensation for the loss he has suffered by reason of the Buyer s default. The compensation shall not exceed that part of the price which is properly attributable to the part of the goods in respect of which the contract is terminated. Payment 17. Unless otherwise agreed, the agreed purchase price, together with value added tax, if any, shall be invoiced with one third at the formation of the contract, one third when the Seller gives written notice that the bulk of the goods are ready for delivery. Final payment shall be invoiced at delivery of the goods. The invoiced amount becomes due 30 days after the date of the invoice. 18. If the Buyer fails to pay, the Seller shall be entitled to interest from the due date at the rate of interest determined by the law on late payments in the Seller s country. 88 If the Buyer fails to pay by the due date, the Seller shall also, after having notified the Buyer in writing thereof, suspend performance of his contractual obligations until payment is made. 19. If the Buyer has failed to pay the amount due within three months after the due date, the Seller may terminate the contract by written notice to the Buyer and, in addition to interest on late payment, claim compensation for the loss he has suffered. The compensation shall not exceed the agreed purchase price. Retention of Title 20. The goods shall remain the property of the Seller until paid for in full, to the extent that such retention of title is valid. Liability for Defects 21. The Seller shall, in accordance with the provisions of Clauses below, remedy any defect in the goods resulting from faulty design, materials or workmanship. The Seller is not liable for defects arising out of material provided by the Buyer or a design stipulated or specified by him. 22. The Seller s liability does not cover defects caused by circumstances, which arise after the risk has passed to the Buyer. The liability does not, for example, cover defects due to conditions of operation deviating from those anticipated in the contract or to improper use of the goods. Nor does it cover defects due to faulty maintenance or incorrect installation from the Buyer s side, alterations undertaken without the Seller s written consent or faulty repairs by the Buyer. Finally the liability does not cover normal wear and tear or deterioration. 23. The Seller s liability is limited to defects which appear within a period of one year from the date of delivery of the goods. If the goods are used more intensely than agreed, this period shall be reduced proportionately. 24. For parts, which have been repaired or replaced under Clause 21, the Seller shall have the same liability for defects as for the original goods for a period of one year. For other parts of the goods the liability period referred to in Clause 23 shall be extended only by the period during which the goods could not be used due to a defect for which the Seller is liable. 25. The Buyer shall notify the Seller in writing of a defect without undue delay after the defect has appeared and in no case later than two weeks after the expiry of the liability period defined in Clause 23 as supplemented by Clause 24. The notice shall contain a description of how the defect manifests itself. If the Buyer fails to notify the Seller in writing within the above time limits, he loses his right to make any claim in respect of the defect. If there is reason to believe that the defect may cause damage, notice shall be given forthwith. If notice is not given forthwith, the Buyer loses the right to make any claim based on damage which occurs and which could have been avoided if such notice had been given. 26. After receipt of a written notice under Clause 25, the Seller shall remedy the defect without undue delay. Within this limit the time for remedial work shall be chosen in order not to interfere unnecessarily with the Buyer s activities. The Seller shall bear the costs as specified in Clauses Remedial work shall be carried out at the Buyer s premises unless the Seller finds it appropriate to have the defective part or the goods sent to him for repair or replacement at his own premises. The Seller shall carry out dismantling and re-installation of the part if this requires special knowledge. If such special knowledge is not required, the Seller has fulfilled his obligations in respect of the defect when he delivers a duly repaired or replaced part to the Buyer. 27. If the Buyer gives such notice as referred to in Clause 25, and no defect is found for which the Seller is liable, the Seller shall be entitled to compensation for the work and costs which he has incurred as a result of the notice. 28. If remedy of the defect requires intervention in other equipment than the goods, the Buyer shall be responsible for any work or costs caused thereby. 29. All transports in connection with repair or replacement shall be at the Seller s risk and expense. The Buyer shall follow the Seller s instructions regarding how the transport shall be carried out. 30. The Buyer shall bear the increase in costs for remedying a defect which the Seller incurs when the goods are located elsewhere than at the destination stated in the contract or if no destination has been stated the place of delivery. 31. Defective parts, which have been replaced under Clause 21, shall be placed at the Seller s disposal and shall become his property. 32. If the Seller fails to fulfil his obligations under Clause 26 within a reasonable time, the Buyer may by written notice require him to do so within a final time. If the Seller fails to fulfil his obligations within that time limit, the Buyer may at his option: a) have the necessary remedial work carried out and/or have new parts manufactured at the Seller s risk and expense, provided that the Buyer proceeds in a reasonable manner, or b) demand a reduction of the agreed purchase price not exceeding 15 per cent thereof. If the defect is substantial, the Buyer may instead terminate the contract by written notice to the Seller. The Buyer shall also be entitled to such termination where the defect remains substantial after measures referred to in a). In case of termination, the Buyer shall be entitled to compensation for the loss he has suffered. The compensation shall not, however, exceed 15 per cent of the agreed purchase price. 33. Regardless of the provisions of Clauses 21 32, the Seller shall have no liability for defects in any part of the goods for more than two years from the start of the liability period referred to in Clause The Seller shall have no liability for defects save as stipulated in Clauses This applies to any loss the defect may cause, such as loss of production, loss of profit and other consequential economic loss. This limitation of the Seller s liability shall not apply, however, if he has been guilty of gross negligence. Liability for Damage to Property Caused by the Goods 35. The Buyer shall indemnify and hold the Seller harmless to the extent that the Seller incurs liability towards any third party in respect of loss or damage for which the Seller is not liable towards the Buyer according to the second and third paragraphs of this Clause. The Seller shall have no liability for damage caused by the goods: a) to any (movable or immovable) property, or consequential loss due to such damage, occurring while the goods are in the Buyer s possession, or b) to products manufactured by the Buyer or to products of which the Buyer s products form a part. The above limitations of the Seller s liability shall not apply if he has been guilty of gross negligence. If a third party lodges a claim for compensation against Seller or Buyer for loss or damage referred to in this Clause, the other party to the contract shall forthwith be notified thereof in writing. The Seller and the Buyer shall be mutually obliged to let themselves be summoned to the court or arbitral tribunal which examines claims against either of them based on damage or loss alleged to have been caused by the goods. The liability as between the Seller and the Buyer shall, however, always be settled by arbitration in accordance with Clause 39. Grounds for Relief (Force Majeure) 36. The following circumstances shall constitute grounds for relief if they impede the performance of the contract or makes performance unreasonably onerous: industrial disputes and any other circumstance beyond the control of the parties, such as fire, war, mobilization or military call up of a comparable scope, requisition, seizure, trade and currency restrictions, insurrection and civil commotion, shortage of transport, general shortage of materials, restrictions in the supply of power and defects or delays in deliveries by sub-contractors caused by any such circumstance as referred to in this Clause. The above described circumstances shall constitute grounds for relief only if their effect on the performance of the contract could not be foreseen at the time of formation of the contract. 37. The party wishing to claim relief under Clause 36 shall without delay notify the other party in writing on the intervention and on the cessation of such circumstance. If grounds for relief prevent the Buyer from fulfilling his obligations, he shall reimburse the expenses incurred by the seller in securing and protecting the goods. 38. Notwithstanding other provisions of these General Conditions, either party shall be entitled to terminate the contract by notice in writing to the other party, if performance of the contract is delayed more than six months by reason of any grounds for relief as described in Clause 36. Disputes. Applicable Law 39. Disputes arising out of or in connection with the contract shall not be brought before the court, but shall be finally settled by arbitration in accordance with the law on arbitration applicable in the Seller s country. 40. All disputes arising out of the contract shall be judged according to the law of the Seller s country.
91 NOTES
92 GCE Norden AB Källvattengatan 9, Box 21044, SE Malmö Telephone: +46 (0) , Fax: +46 (0) Art. Nr. CATMEDSE0512. Edition 2/2012. Alterations are subject to change without notice hz GCE 2012
EDITION 1/2014 MEDICAL CATALOGUE
EDITION 1/2014 MEDICAL CATALOGUE GCE worldwide Sales office Sales representation Headquarters Production units Stock point www.gcegroup.com the GCE Business GCE has almost 100 years of experience in the
ACCESSORIES OXYGEN-THERAPY
OXYGEN-THERAPY English version 11/ 2010 HUMIDIFIERS The humidifier is used to humidify the oxygen or the medical air delivered to the patient through the respiratory tract. Screwed to the outlet of a flowmeter
DEBSON TM2 OXYGEN THERAPY FLOWMETERS WITH PRE ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION. English version 11/ 2 010
DEBSON TM2 MORE SAFETY GAS FLOW BETWEEN TWO POSITION English version 11/ 2 010 RAIL MOUNTING SYSTEMS AFNOR rail mounting systems BS rail mounting systems (neutral) DIN rail mounting systems OHMEDA rail
RTM3 OXYGEN-THERAPY FLOWMETERS WITH FLOATING BALL
RTM3 OXYGEN-THERAPY FLOWMETERS WITH FLOATING BALL English version 11/ 2010 OXYGEN-THERAPY RAIL MOUNTING SYSTEMS AFNOR rail mounting systems BS rail mounting systems (neutral) DIN rail mounting systems
Description TERMINAL UNIT AFNOR NF S 90-116
PF-01US-00O2 PF-02AU-00O2 PL-23A0-10O2 TERMINAL UNIT AFNOR NF S 90-116 UNI base block with welding nut for Oxygen Outlet AFNOR NF S 90-116 for Oxygen Coloured ring for oxygen Complete terminal units AFNOR
REGSON TM2 OXYGEN-THERAPY PRESSURE REGULATORS WITH FLOWMETER WITH PRE-ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION
REGSON TM2 OXYGEN-THERAPY PRESSURE REGULATORS WITH FLOWMETER WITH PRE-ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION English version 11/ 2 010 REGSON TM2 The REGSON TM2 pressure regulator,
Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!
Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm
Saferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
For over 40 years, the leader in. nitrous oxide. equipment technology.
Conscious Sedation Delivery Systems For over 40 years, the leader in nitrous oxide equipment technology. Made in U.S.A. Over 40 years ago Fraser Sweatman pioneered the technology used for safe delivery
EDITION 2/2013 CENTRAL GAS SUPPLY HIGH PRESSURE MANIFOLDS AND OUTLET POINTS FOR INDUSTRIAL GASES
EDITION 2/2013 CENTRAL GAS SUPPLY HIGH PRESSURE MANIFOLDS AND OUTLET POINTS FOR INDUSTRIAL GASES GCE WORLDWIDE Sales office Sales representation Headquarters Production units Stock point www.gcegroup.com
UNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
Fredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.
Conveyor Solutions Whatever your logistic needs, we can offer a conveyor solution. Our flexible systems primary and secondary packaging for single and multi packages, can transport your goods from one
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
Many Products...One Source
PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K
Turbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
SAFETY SAFETY APPAREL 20,000 PSI
SAFETY APPAREL TurtleSkin Water Armor is designed for UHP safety. Protection up to 2800 bar or 40,000 psi One size fits all money-saving design Modular design allows you to buy only what you need Replacement
HG600/HG800. Hydro-Power Unit. Installation and Operation Guide
HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves
1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire
Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
Watts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
THERAPY EQUIPMENT LTD
QUALITY UK MANUFACTURER THERAPY EQUIPMENT LTD Manufacturers of Health Care Equipment SINCE 1983 2 7701 - DIAMOND HIGH SUCTION CONTROLLER 0 9506 - DIAMOND RANGE AIR FLOWMETER & PROBE 1 4550 - RAIL MOUNTED
AUTOMATIC CHANGEOVER MANIFOLD Series 915
AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm
Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA. REF. 10049600 Rev. L
REF. 10049600 Rev. L Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA TABLE OF CONTENTS WARNINGS 2 DESCRIPTION AND MECHANICAL ASSEMBLY 2 CONNECTION
Accessories. Fittings 2. Products assembly 4. Tube Spike 3/5 mm 8 T.N.L. 9. Vacuum Breaker 10. Line Flush Valve 11. Pressure Indicator 12
Accessories For irrigation systems Version 1.0 Fittings 2 Products assembly 4 Tube Spike 3/5 mm 8 T.N.L. 9 Vacuum Breaker 10 Line Flush Valve 11 Pressure Indicator 12 Fittings Manifold 8 outlets To distribute
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
SMD Rework Station TABLE OF CONTENTS
SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating
MEDICAL CATALOGUE Nordic Central Gas Range
EDITION 1/2015 MEDICAL CATALOGUE Nordic Central Gas Range GCE WORLDWIDE Sales office Sales representation Headquarters Production unit Stock point www.gcegroup.com THE GCE BUSINESS GCE has almost 100 years
Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)
OPTIONS: USE: AVAILABLE MODELS: Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) DESCRIPTION The ADCA PRV47 pilot operated pressure reducing valves are designed for use on steam,
RUBBER SLEEVE KNIFE GATE VALVE
RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve
Proportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
Regulator Options and Accessories
Regulator Options and Accessories Regulator accessories are available separately or mounted on Swagelok regulators. Some accessories limit regulator pressure or temperature ratings. Additional materials,
Product catalogue, pipe and sewer cleaning systems
Product catalogue, pipe and sewer cleaning systems Nozzles Rotorjet trolley Hose reels Cleaning devices www.hammelmann.com Contents (Navigation via Bookmarks) Rotorjet trolley Rotary joints, spray pipes
Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003
Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003 Knowing the functions of the anesthetic delivery system
Waste Oil Handling, Spill Containment & Lighting
58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC
RECOVERY SUPEREVAC 29 RECOVERY 1/4" 4-IN-1 BALL VALVE TOOL For vacuum, charge, cores and recovery 18997 18975 18971 18978 18979 Remove and replace Schrader cores without losing charge. Extra 1/4" side
Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:
Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees
Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.
Picture Item No. Description RO- 0010 Brass Water Feed 1. 3/4" FIP with 1/4" hole 2. Using on R.O. tank RO- O020 Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP RO- 0030 Brass
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
T U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and
NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE
B4 NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE AVAILABLE IN CARBON AND STAINLESS STEEL 23 THEORY
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
ATTIX 30, 40 & 50 WHY COMPROMISE. Easy handling and easy maintenance
ATTIX 30, 40 & 50 WHY COMPROMISE Easy handling and easy maintenance The perfect solution for professionals on the move The ATTIX 30 is the new and compact generation of the ATTIX range - representing a
Robot Welding Torch System
T e C H N O L O G y f O R T H e W e L d e R s W O R L d. Robot Welding Torch System W W Robot welding torch system... The universal MIG/MAG-torch system for robot welding: A new interface and cable assembly
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Pressure calibration equipment
Pressure calibration equipment Pressure calibration evolution 1925 Westertoren in Amsterdam 30 meter mercury column (±40 bar) 1950 comparison test pump 21 st century Stiko gas driven differential deadweight
Porter Instrument Division
AA173200i Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 USA Tel: 215-723-4000 Ref. 10545100 Rev. F CE Notice The symbol on this product indicates compliance
Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Hose and Tube Fittings Series 1-3
Embracing Challenge Hose and Tube Fittings Series 1-3 out of plastics PP, PVDF, PTFE Series 1 Special Features Corrosion resistant Gas tight Easy to handle Different connection threads Application Hose
Bringing good things ahead
Bringing good things ahead Whatever your logistic needs, we can offer a conveyor solution. Our flexible systems primary and secondary packaging for single and multi packages, can transport your goods from
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
www.gentechealthcare.com MEDICAL GAS SYSTEMS & DEVICES OVERVIEW Technology for a Better Future
MEDICAL GAS SYSTEMS & DEVICES OVERVIEW 00 COMPANY INTRODUCTION Company Overview Genstar Technologies Company, Inc (GENTEC ), founded in 1969, is a world class manufacturer of high quality apparatus for
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
AIR-AIR PRESSURE MULTIPLIER (BOOSTER)
AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally
Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
Workshop Compressors CLASSIC Series
www.kaeser.com Workshop Compressors CLASSIC Series Displacement: 210 to 40 l/min Pressure: 10 bar What do you expect from your CLASSIC workshop compressor? Quality results can be achieved only by using
Fixtures - Parts - Accessories to shampoo bowls
Page 1??? - For what brand of bowl do you need parts??? Find out by looking on the bottom of the bowl, between the front and strainer, where molded in the bottom is the brand and model number. For example,
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
STABITHERM INSTALLATION & SERVICE BOOKLET
STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow
stainless steel pre-assembled manifolds
TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and
Blowdown vessels Meeting the requirements of HSE PM60
Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED
SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED Domestic and Non-Domestic Meter Regulators G940/G941 - Domestic Meter Regulator Domestic regulator offering high performance in a compact unit. Sizes:
ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES
ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES The Gold Standard Cardiovascular QUADROX PLS and ROTAFLOW 3 QUADROX PLS AND ROTAFLOW INNOVATIVE PERFORMANCE AND RELIABILITY
Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.
Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without
CG-1171-20 PTFE Diaphragm Liquid Transfer Pump
3800 N. Mill Road Vineland, NJ 08360 Phone: 800.843.1794 Fax: 800.922.4361 CG-1171-20 PTFE Diaphragm Liquid Transfer Pump This is the safety alert symbol. It is used to alert you to potential personal
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
Welding and cutting torches - light version page 2. standard version page 4. 3-tube cutting torches and attachments (nozzle mix type) page 7
Welding and cutting torches - light version page 2 Welding and cutting torches - standard version page 4 3-tube cutting torches and attachments (nozzle mix type) page 7 Pressure regulators page 8 Safety
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
CHEMICAL CLEANING UNIT Product number: 737189
CHEMICAL CLEANING UNIT Product number: 737189-1 - v.05/16 Content Page Intro 3 Specifications 4 Installation 5 Safety precautions 7 Maintenance 8 Spares and Accessories 8 Unitor Chemicals 9 Notes 10-2
RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID
ROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #
Shower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
Variable Area Flowmeters
www.swagelok.com Variable Area Flowmeters G Series and M Series Glass and metal (armored) tube models, including miniature armored model Highly accurate measurement with individually calibrated scales
SUPERYACHT SPARES. Nozzles and portable monitors. www.superyachtspares.com / [email protected] / +31 183 639193
Nozzles and portable monitors Rosenbauer - Nozzles and portable monitors EN Maximum extinguishing effect. Minimal water consumption. The Rosenbauer nozzle enables the manual adjustment of the water flow
Hose Clamps & Fittings
All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw
Battery Powered Thermal Mass Flow Meters for Gases
red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized
50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance
02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW
KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja 12-14 tel: 061307-3801 [email protected]. Clamps Clamping devices
04000 Clamps Clamping devices 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 297 04010 Adjustable straps Tempered steel 1.1191 Black oxide finish nlm 04010-101 Suitable thrust
MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com
MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM Designed for centralized medical air production in hospitals and clinics, NOVAIR medical air stations ensure the continuous supply of the medical gas
Ergonomical Polyurethane recoil hose
C Recoil PU Hose xx l/ sec 100% PUR -30 C - +60 C Ergonomical Polyurethane recoil hose Assembled in Denmark 2/4/6/8 m Features > > Straight ends of 150 mm / 500 mm > > Top quality PUR raw material 98 Shore
Powers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features
P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008