Automotive Air-Conditioning Service Equipment Ariazone 5001 OPERATOR MANUAL Ariazone 5001
|
|
|
- Steven Clark
- 10 years ago
- Views:
Transcription
1 Automotive Air-Conditioning Service Equipment Ariazone 5001 OPERATOR MANUAL Ariazone Automotive A/C Service Station 1
2 Contents Page 1. Introduction Safety firts Technical Features Main Parts & Features Preparing the machine for use Display descriptions Cylinder filling procedure Connecting Ariazone 5001 to the A/C system Recovery & Recycling Mode Evacuation Mode Oil or/and UV dye Injection Mode Refrigerant Charge Mode Cylinder Air Purge Service Procedure Ariazone Automotive A/C Service Station 2
3 1. Introduction Ariazone Automotive A/C Service Station (Recovery, Recycling, Evacuation and Charging System) is a user-friendly tool specifically designed for the automotive air-conditioning technicians, to carry out the following functions: - Testing air conditioning system, - Recovery and recycling the refrigerant from a/c system, - Gauge amount of refrigerant recovered from air-conditioning system. - Gauge amount of oil removed from air-conditioning system (if any), - Evacuate air-conditioning system, - Charge lubrication oil or UV dye by volume into the air-conditioning system, - Electronically charge the refrigerant into a/c system by weight. The unit is a microprocessor controlled system. This provides electronically controlled functions, whilst keeping the operator constantly informed and in full control. This unit has been designed and build to be long lasting and with high level of reliability including maximum safety for the operator. The operator needs only to be responsible for the proper use and maintenance of the unit, in accordance with the instructions found in this manual. This manual contains important information pertinent to operator safety, and must accompany the unit, in the case of sale or transfer to another party. Manufacturer reserves the right to modify this manual and the unit itself at any time without prior notice. Environmental information This product may contain substances that can be hazardous to the environmental or to human health if it's not disposed of properly. Electrical and electronic equipments should never be disposed of in the usual municipal waste, but must be separately collected for their proper treatment (recycling). We also recommend that you adopt appropriate measures for environmental protection: recycling of the internal and external packaging of the product, including batteries (if any). With your help it is possible to protect our planet and improve the quality of life, by preventing potentially hazardous substances being released in to our environment. Ariazone Automotive A/C Service Station 3
4 2. SAFETY FIRTS! Importatnt safety information's Ariazone 5001 unit is extremely simple and reliable in selecting and performing all it s functions. Therefore, the user is not exposed to any risk, if the general safety guidelines reported below are followed, in association with proper use and maintenance of the unit (improper use and maintenance will reduce the safety of the unit). - Read this user manual carefully before operating the unit. If you do not understand any section of this manual, please contact Ariazone International direct or your nearest Ariazone distributor. - This equipment is to be operated by accredited technician only! Users must have basic knowledge of air-conditioning and refrigeration systems, including potential hazards associated with the handling of refrigerants and systems under high pressure. - Handle refrigerant with care as serious injury may occur. Always wear appropriate protective clothing and safety glasses. - Avoid inhalation of the refrigerant. Use only in well ventilated work areas. - Use only R134a refrigerant with this equipment. - Do not expose the machine to direct artificial heat or rain. - Do not tamper with or change safety control devices or their settings. - The power cable may only be connected to a socket with nominal voltage stated on the rating plate, located at the rear of the unit. - Power lead plug to be connected only to power point with an earth. - When transporting the unit keep upright and remove refrigerant cylinder from platform. - Never operate the equipment with a damaged power lead, replace it immediately. - RISK OF ELECTRICAL SHOCK. Before removing any protective cover from unit, always unplug power lead from power point. - Do not cover ventilation openings when unit is operating. - Maintenance is to be carried out as per the manufacturer recommendation shown in this manual. Only Ariazone approved parts are to be used for maintenance and repairs. - Only autorised technician can mainentance the Ariazone units. - Only non agresive substacens to be used for cleaning of the unit. - Araizone 5001 does not contents flamable gases. Ariazone Automotive A/C Service Station 4
5 3. Technical Features Refrigerant... R134.a Electronic refrigerant scale... +/- 10 g resolution Load cell... 60kg with 150% overload capacity LP and HP gauges... AI-D 68 mm kl.1.0 Recovery cylinder...12kg Recovery pump... Danfoss FR11G, 275W Recovery rate g/min liquid state Vacuum pump... 2 stage, 72 l/min (2.5cfm), Vacuum... 3 x 10-1 Pa Dimensions... W- 580 mm, D- 620, H-1090 mm Weight... 72kg Chassis... Sturdy all steel construction powder coated. Supply voltage V/ 50Hz Noise level... < 70 db (A) Fixed wheels mm (8 ) Heavy duty Caster wheels... 75mm (3 ) Heavy duty Working conditions o C ambient temperature, up to 80% humidity, 2000m altitude Measuring instrument... I kategory (Not to be mixed with II, III, IV category) Approvals... EN Electric safety, EN EMC Ariazone Automotive A/C Service Station 5
6 4. Main Parts & Features 1. Analog Gauges - Two large analogue gauges display suction and discharge pressures. The gauges are mounted on the front panel for easy viewing by the operator. Pressures are displayed in Bar & PSI and temperatures in degrees Celsius. 2. Display - Numerical display indicates the values and LED indicators above and below the numeric display inform the operator whether the display is indicating kg or lb, remaining vacuum time, weight of refrigerant currently within the cylinder, the amount of refrigerant being charged or the amount of refrigerant recovered. 3. Mode Indicator - LED group and membrane switches (keys). Three pairs of LED blocks indicate the mode and status of the unit. These are used in conjunction with the adjacent membrane switches to select the unit functions. Further, once the mode is in operation the pattern in which the LEDs flash, indicate the activity of the system. These can be viewed from several meters. 4. Hand Valves - The console hand valves allows the operator to control the flow of the refrigerant (if desired). 5. Discharge & Suction Service Hoses - A pair of 1.8m (72") hoses are connected to the console, which allows the operator to connect the unit to the vehicle air-conditioning system service ports for testing system pressure, recovering and recharging the refrigerant, oil and/or UV Dye. 6. Service Hose Quick Couplers - Service hose quick couplers allows the operator to connect the unit to the vehicle air-conditioning system service ports without exhausting the refrigerant into the environment. Ariazone Automotive A/C Service Station 6
7 7. Moisture Indicator - The moisture indicator is conveniently mounted on the console for added protection to indicate the condition of refrigerant and filter change intervals. The following colors correspond to the following moisture content: Green or Blue - Dry, Yellow or Pink - Wet, 8. Vacuum Pump Oil Level - Oil level must be checked when the pump is running, the oil level should be even with the line on the vacuum pump sight glass. Under filling will result in poor vacuum performance. Over filling can result in oil blowing from the vacuum pump exhaust. 9. Recovered Oil Drain Reservoir - A plastic vessel of 250ml (8.75oz) is mounted on the right rear of the unit allows the operator to gauge the amount of oil recovered from the air conditioning system (if any). 10. Oil Storage Reservoir - A plastic vessel of 250ml (8.75oz) is mounted on the left rear of the unit, allows the operator to inject oil into air conditioning system automatically. 11. Cylinder platform / Electronic scale 12. Refrigerant Cylinder 12 kg secured with the strap on the platform 13. Cylinder Pressure Indicator - A large pressure gauge is mounted on the back upper side of the unit to indicate to the technician of any air (non-condensable) built up in the storage cylinder. 15. Cylinder vapor hose 16. Cylinder liquid hose with ball valve 17. Brass adapter or adapter hose 18. Fuse - 10A 19. Power switch 20. Cylinder air purge valve Ariazone Automotive A/C Service Station 7
8 5. Preparing the machine for the first use Perform the following steps to prepare the unit before the first use: 1. Remove the nylon wrapped and styrofoam insert behind the cyinder (12). 2. Check to ensure that all of the accessory components are present: - Cylinder (12) - Adapter (17) - Cylinder vapor hose (15) - red - Cylinder liquid hose with ball valve (16) - blue - Service hoses with quick couplers (5) - User's manual - Cylinder strap 3. Check that the cylinder (12) is already placed on the platform (11) and properly secured with the strap provided. Unscrew two securing M6 bolts placed on each side of the platform basis app. 3-4 mm and LOCK them in place with nuts provided. Ariazone Automotive A/C Service Station 8
9 4. Check the vacuum pump oil level (8). The oil level should be even with the line on the vacuum pump sight glass when the pump is not running. 5. Power up (19) the unit. The unit will perform a lamp test, whereby all LED displays are illuminated. This will enable the operator to determine if any displays have failed. After the sequence has been completed, the display (2) will indicate FILT - 99Hr. This is the number of hours left before equipment servicing is required and the amount of refrigerant in the cylinder(12). If the cylinder is delivered empty, display should indicate app. 0kg of refrigerant in the cylinder. If not, please perform TARE function (0kg calibration, paragraph 15). 6. Mode Selection. To select a mode of operation, press either the "UP" or "DOWN" arrow keys until the LED indicator (3) is beside the desired function. Press 'START' key which will cause the unit to enter the selected mode. Any mode that has been selected can be exited by pressing the 'STOP' key. Note, that if a valid key was depressed, the unit will beep. If an inappropriate selection has been made, i.e. attempting to select a mode whilst another mode is in operation, the unit will ignore the pressed key and will not beep. Ariazone Automotive A/C Service Station 9
10 7. Refrigerant cylinder (12) fitted on a platform is evacuated during the production process. Anyway, check if refrigerant cylinder (12) is evacuated (during the transport and delivery, vacuum could be lost). If the vacuum is lost, please perform following steps to Evacuate refrigerant cylinder (12) before filling it with refrigerant: - Connect blue service hose (5) to cylinder (12) by using adaptor (17). - Open cylinder (12) valve, service hose (5) quick coupling and handle (4) on the unit panel. - Press the 'UP" key twice to select Evacuation function. Press, "START" and with the keys "UP" and "DOWN" select 30 minutes. Press "START" key again and the unit will start the evacuation process. - After 30 min. the unit will automatically stop. Close the cylinder valve, disconnect the service hose (5) and adapter (17) from cylinder, place to the storage ports and connect liquid hose (16) to the cylinder liquid side and vapor hose (15) to the cylinder vapor side. LIQUID AND VAPOR HOSES MUST BE CONNECTED TO VAPOR AND LIQUID PORTS ON THE STORAGE CYLINDERS. INCORRECT CONNECTION WILL CAUSE CHARGING TO BE VERY SLOW. 9. Open both cylinder valves and open liquid hose (16) ball valve. Ariazone 5001 is now ready for use. Ariazone Automotive A/C Service Station 10
11 6. Display descriptions HIgH PrES - Excess pressure in refrigerant cylinder TArE - Calibrating the weight display to read with an empty cylinder on platform. SPAn - Calibrating of the refrigerant electronic scale Err1 - Disconnected load cell lead or faulty load-cell. CYL FULL - Refrigerant weight exceeds maximum allowable limit and will not recover any more refrigerant no ref - No refrigerant pressure in service hoses, or manifold hand valves are not open done - The selected function is completed FILT 99Hr - Displays filter life in number of hours when machine is switched on PAUS - Recovery pause is running, for duration of three minutes. busy - Purge solenoid opens to cylinder vapour port to pressurize oil separator CYL - This display allows the operator to set the maximum allowable refrigerant weight in cylinder. Ariazone Automotive A/C Service Station 11
12 7. Filling cylinder with refrigerant procedure The refrigerant cylinder (12) may be filled with refrigerant by following procedures. Using refillable cylinder procedure Have cylinder sitting upright, connect the suction (blue) service hose (5) to storage cylinder liquid valve by using the refrigerant cylinder adapter (17) supplied, open liquid valve on storage cylinder, open service hose quick coupling (5) and console blue hand valve (4) >>> Using disposable cylinder procedure Connect the suction (blue) service hose (5) to a storage cylinder valve by using the refrigerant cylinder adapter (17). Turn upside down the cylinder for liquid, open the valve on the storage cylinder, open service hose quick coupling (5) and console blue hand valve (4) >>> >>> With "UP" key select the Recovery function and press "START". With "UP" or "DOWN" keys select amount of refrigerant to be transferred. Press "START" key and unit will automatically transfer the refrigerant from storage cylinder to the unit cylinder (12). When the desired amount of refrigerant is transferred, close the storage cylinder valve and allow the unit to recover the refrigerant from the service hose (5). Once the function is completed the unit will display symbol "DONE" and the amount of refrigerant transferred will be displayed in kg or lb on main display (2). The cylinder may be taken to your refrigerant supplier and refilled. We recommend that the cylinder is not filled to it's maximum capacity or the unit will not allow you to recover, due to the safety features incorporated. WARNING: - Always keep a minimum of 2kg in the cylinder (12). - Do not allow the cylinder to be filled above 80% of it's capacity. - Never transport an overfilled cylinder. Refrigerant expands when heated and may cause the pressure relief valve to open and exhaust refrigerant in to the atmosphere or the cylinder may rupture. Ariazone Automotive A/C Service Station 12
13 8. Connecting Ariazone 5001 to vehicle A/C system Use the service hose (5) quick couplings to connect the hoses to the A/C system service ports, bearing in mind that BLUE must be connected to the low-pressure (suction) side and RED to high pressure (discharge) side. If the system is equipped with a single service port, connect only the appropriate hose. Note: Before connecting the quick couplers, clean the a/c ports of any foreign material. Winding the quick coupler hand wheel clockwise, will allow the refrigerant to flow through the hoses. Turning hand wheel in opposite direction, the flow will be closed. If there is any refrigerant in the air-conditioning system, the pressure gauges will indicate a pressure rise. Important: Console manifold hand valves (4) need to stay closed, NOT to allow refrigerant to enter into the unit until the required function has been selected. The unit gauges (suction & discharge) are important and useful instruments. The operator should have basic understanding of gauge readings and air-conditioning system operation, in order to correctly diagnose any possible system malfunction. Ariazone Automotive A/C Service Station 13
14 9. Recovery & Recycling Mode The purpose of the Recovery & Recycling mode is to recover refrigerant from the air conditioning system, which will condense, purify and store the liquid refrigerant in the unit cylinder ready for re-use. To initiate the Recovery mode, press the 'UP' key once, followed by 'START' on the console. Display shows ( ). Now, there are two choices: 1. Press "START" key again to recover the whole amount of the refrigerant from the A/C system or storage cylinder. 2. With "UP" or "DOWN" keys to select desired quantity of refrigerant to be recovered from the a/c system or storage cylinder. After the quantity selection, press "START" key. Note: Open the hand manifold valves (4) on the console to allow the flow of the refrigerant from the a/c system before making the above selection (valves on the unit storage cylinder (12) and ball valve on the cylinder liquid hose (16) must be open, too). During the recovery process, the Recovery mode LED indicator will be ON and the display (2) will indicate the amount of refrigerant being recovered. In normal operation the above condition will be maintained until a vacuum of -0.4 bar is reached at either the discharge or suction ports. When this occurs, the machine will beep once, and the unit will enter in Recovery "PAUSE" mode. In this mode, the unit will shut down the recovery function and pause for 3 min., which during this time the recovery mode indicator will be ON constantly. The display (2) will indicate "PAUSE". During this function, the unit is monitoring whether the air-conditioning system pressure is increasing, due to any refrigerant that may be left in the accumulator or dryer. If the pressure increases above zero, the machine will re-start the recovery function automatically and recover the rest of the remaining refrigerant. If at the end of Recovery process a sufficient vacuum of -0.4 Bar has been maintained, the unit will stop, the display (2) will indicate 'DONE' and the amount of refrigerant recovered will be displayed in kg (or lb) depending on the operator s selection. Press 'STOP' on the console, the unit will display "busy" for 5 seconds. Ariazone Automotive A/C Service Station 14
15 IMPORTANT: At completion of recovery function, open the valve on recovered oil vessel (9) to gauge amount of oil (if any) that has been recovered. Conditions that will halt the recovery mode 1. Refrigerant cylinder (12) full. To protect the storage cylinder (12) being overfilled, the unit will not allow the operator to recover refrigerant once it has reached 80% of its capacity. 2. Air conditioning system empty. If the A/C system pressure is not above atmospheric pressure, the recovery function will not be activated. 3. High Pressure. If the operating pressure of the unit exceeds 25 bar (340 PSI), the unit will stop and display 'HigH - PrES'. The following can cause the above: Cylinder (12) valves not open. Restricted cylinder hose (16). Check the ball valve. Excessive high ambience temperatures. Excessive air in refrigerant into the cylinder (12). Faulty pressure control. In all the above circumstances, press the 'STOP' key to return to the machines initial mode. Ariazone Automotive A/C Service Station 15
16 10. Evacuation Mode In the evacuation mode the air and moisture in the air conditioning system is removed and exhausted to the atmosphere. The evacuation pump in the Ariazone system is capable of developing a vacuum of bar (29.99 in hg). The evacuation mode runs for a predetermined time selected by the operator. To initiate evacuation mode, press the 'UP' key twice, followed by the 'START' key. Select the desired evacuation duration by pressing the 'UP' key to increase or 'DOWN' key to decrease time duration. Once the desired time has been selected press the 'START' key and the function will commence. Note: During evacuation mode hand valves (4) on the console must be open. The evacuation time can be set from one minute to two hours. At any time the evacuation time can be paused or cancelled by pressing the stop button once to pause, or twice to cancel the function. The Ariazone system has a unique function that if the evacuation function is selected and there is residual refrigerant in the air conditioning system, greater then 0.6 bar or 9 psi, the unit would detect this condition, whereby it will beep six times to warn the operator. After this warning the unit will automatically recover the residual refrigerant once it has recovered the entire refrigerant it will start the selected evacuation function automatically. Note: After the evacuation process is completed, close both hand valves on console (4). By closing the valves the unit is "isolated" from the A/C system to allow for monitoring of any possible vacuum leak, that may exist in the air- conditioning system. This is achieved by monitoring the suction and discharge gauges. Ariazone Automotive A/C Service Station 16
17 11. Oil or/and UV Dye Injection Mode The purpose of the oil injection mode is to batch a user-defined quantity of refrigerant oil or/and UV Dye from the graduate reservoirs on the unit to the vehicle air-conditioning system. Important: The unit requires that the air conditioning system has previously been evacuated to a maximum vacuum before this function can be carried out. Make sure you have sufficient oil or/and UV Dye in the oil reservoir (10). Keep hand valves (4) closed on the console. Open the ball valve on the oil reservoir (10) and note the amount of oil being injected, by the graduations on the reservoir. Close the ball valve when the correct amount has been injected. Warning: If the oil reservoir (10) valve is not closed, excessive oil will be charged into the air conditioning system, or the oil will be blown out of the reservoir when charging a system. On A/C systems without discharge port, oil and UV dye can be carefully injected through suction port. That case open both hand valves (blue and red) (4) on the console. CAUTION: If service port is located close or on the compressor make sure to rotate the compressor nub 4-5 times by hand before start the A/C system. If this process is not carried out the compressor may be severally damaged. Conditions that will prevent oil or/and UV dye injection: - Insufficient vacuum. - Hand valves (4) not opened on console. - Schrader valve on A/C system service port not depressed. - No oil in the reservoir (10). Ariazone Automotive A/C Service Station 17
18 12. Refrigerant Charge Mode The purpose of the refrigerant charge mode is to batch a user-defined weight of refrigerant into the air-conditioning system. Important: It is recommended that the A/C system is always properly evacuated and leak tested, before refrigerant is charged in to the A/C system. To initiate charging mode, press the 'UP' key three times (or DOWN once), followed by the 'START' key. Select the desired refrigerant amount by pressing the 'UP' key to increase or 'DOWN' key to decrease. The smallest increment of refrigerant charge weight is 0.01kg. If the units of weight are in lb the smallest increment of refrigerant charge weight is 0.02lb. The maximum refrigerant weight that can be set at this point is determined by the actual refrigerant weight available in the cylinder (12). Holding the 'UP' or 'DOWN' keys for longer than two second will cause the increments of weight change to increase or decrease rapidly. Once the refrigerant charge weight has been set, press the 'START' key and open appropriate hand valve depending on weather you are charging with the engine running or stationary (if the A/C system is OFF or ON). The display (2) will start from zero and will indicate the amount of refrigerant that has been charged into the air-conditioning system. This function can be paused at any time, by pressing the 'STOP' key once, or twice, to cancel the function. If the charge function has been paused, the amount of refrigerant that has been charged to that point will be displayed, to continue the charge function press the 'START' key. Once the present refrigerant weight has been charged, the charge function will automatically stop and the display will indicate 'DONE'. The operator can return the machine to its initial state by pressing 'STOP' key on the console. Conditions that will prevent refrigerant charging - If there is little or no refrigerant in cylinder (12). The operator will not be able to select the desired amount of refrigerant required. - If the cylinder (12) valve is closed. - If the hand manifold valve (4) console is closed. - If the A/C system service port Schrader valve is not depressed. Ariazone Automotive A/C Service Station 18
19 13. Cylinder Air Purge Once a week check if there is non-condensable (air) build up in the refrigerant cylinder. First, measure the ambient temperature. Then read the cylinder pressure on rear gauge (13) and compare it with the temperature pressure chart, affixed to the machine. If the cylinder pressure is higher than the pressure/temperature chart, there are non-condensable gases (air) in the cylinder (12). Slightly OPEN ball valve (20) to purge the non-condensable gases (air) from the cylinder (12) and bring back the pressure to the recommended chart values. Note: After recovery process it is normal that cylinder pressure is higher than the pressure/temperature chart shows. Always read the cylinder pressure gauge (13) first thing in the morning before operating the machine. Example: Ambient temp. 20 o C, the cylinder pressure should be 4.7 bar (68 PSI). Ambient temperature Air purge gauge readings (C o ) bar PSI Ariazone Automotive A/C Service Station 19
20 14. Service Procedure The following table describes the service intervals of the unit. Every 100 Working Hours /Once a Year Service The service alarm will alert the operator for maintenance and filter replacement. Interval Component Procedure Every 100 Hr / Once a year Main Filter Dryer Replace Every 100 Hr / Once a year Primary Recovery Line Filter Replace Every 100 Hr / Once a year Vacuum Pump Oil - 330ml Drain and refill Every 100 Hr / Once a year Service hose "O" rings Check / Replace Every 100 Hr / Once a year Gauges Test calibration Every 100 Hr / Once a year Weight Platform Test calibration Service Kit 100Hr (Vacuum pump Oil (330ml) x 2, Recovery Line Filter, Main Filter Dryer, Service Hoses "O" rings) Art. No: Pack. Dimensions: 120 x 200 x 210mm Every 300 Working Hours Service The unit requires 100 hour service plus replacing of oil separator, primary charging filter and recovery pump (compressor) oil. Interval Component Procedure 300 Hours Oil Separator Replace 300 Hours Primary Charging Line Filter Replace 300 Hours Recovery Pump Oil - 400ml Drain and refill 300 Hours Main Filter Dryer Replace 300 Hours Primary Recovery Line Filter Replace 300 Hours Vacuum Pump Oil - 330ml Drain and refill 300 Hours Service hose "O" rings Check / Replace 300 Hours Gauges Test calibration 300 Hours Weight Platform Test calibration Service Kit 300Hr (Vacuum pump Oil (330ml) x 2, Recove. Line Filter, Main Filter Dryer, Service Hoses "O" rings, Charging Line Filter, Oil Separator, Recov. Pump Oil - 500ml) Art. No: Pack. Dimensions: 120 x 200 x 210mm Manufacturer recommends a record of all services on the machine to be kept. Note: Always wear appropriate protect clothing and safety glasses when servicing the machine. Ariazone Automotive A/C Service Station 20
21 Notes: The company: Ariazone International Europe 15-ti Korpus bb., 6000 Ohrid, MACEDONIA Hereby declares that the product: D E C L A R A T I O N OF C O N F O R M I T Y Ariazone Automotive A/C Service Station Meets all requirements of European Directives: 2006/95/EC (ex 73/23/EEC) Low Voltage Directive 2004/108/EC Electromagnetic Compatibility 98/37/EC Machine Directive and subsequent amendments entered in force to the date of declaration. The following standards and technical specifications, conforming to EEC Harmonized Regulations were applied: EN :2001 with cross references: EN 60227, EN 60245, EN 60309:2003; EN 60799, EN 60804, EN EN ; EN ISO ; EN ISO ; EN ISO :2003; EN ISO :2003 The producer also declares that equipment confirms Directives and Standards when used according to manufacturer specifications. Date and place of issuing: Ohrid, Serial No: Ariazone International Melbourne, Australia T: Ariazone International Europe Ohrid, Macedonia T: Made in Macedonia Ariazone Automotive A/C Service Station 21
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves
Specifications Blue (Low) Gauge 0-120 PSI Blue Hose 1 / 4 IN. FFL x 4 FT. 9 IN. Red (High) Gauge 0-500 PSI Red Hose 1 / 4 IN. FFL x 4 FT. 9 IN. Yellow Hose 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2%
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Air conditioning service unit CAAS500
Air conditioning service unit CAAS500 OPERATING INSTRUCTIONS TES1453 09/2004 C A A S 5 0 0 O P E R A T I N G I N S T R U C T I O N S P a g e 2 IMPORTANT THIS MANUAL CONTAINS INFORMATION PERTINENT TO OPERATOR
Operations and Maintenance Manual
Operations and Maintenance Manual FOR MODELS 1234XL 1090XL 1095XL P/N 99971-SP Rev. 1/98 Table of Contents Set-Up...1 Introduction... 1 Unit Set-Up... 1 White Industries Models...1 1090XL Panel and 1234XL
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Car and commercial cial air conditioning service solutions
Car and commercial cial air conditioning service solutions THE STANDARD IN INFORMATION AND DIAGNOSTICS SYSTEMS INTRODUCTION For the KoolKare range of vehicle air conditioning service equipment we went
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
EKOS Cart. Instructions for Use
EKOS Cart Instructions for Use EKOS Corporation 11911 North Creek Parkway South Bothell, WA 98011 USA (425) 415-3100 (tel) (425) 415-3102 (fax) [email protected] (e-mail) - 1-4913-002 REV E Intended Use
Recharge Procedure for Telemark TVP-2000 and TVP-3500
Recharge Procedure for Telemark TVP-2000 and TVP-3500 Required items: 1.) Refrigeration service manifold. 2.) Charge recovery system. 3.) Dry nitrogen gas. If a high pressure cylinder is used, a pressure
Subject: 2005 Air Conditioning Service Guidelines
Date: June 27, 2005 Bulletin Number: 05D-J-114 To: DDG Headquarters and Branches and Jobbers Category: Service From: Steve Sigg, Product Service and Training Line(s): 10 and 15 Subject: 2005 Air Conditioning
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
Tools & Equipment Robinair
Tools & Accessories 2 Robinair Product overview AC RAnge Robinair is VDA and TüV approved and carries SAE-J approval. Robinair is approved by the following OEM s: 3 Robinair Moving from R134a to R1234yf
Operating Manual for Model 34988. Recovery, Recycling, Recharging Unit
Operating Manual for Model 34988 Recovery, Recycling, Recharging Unit Model 34988 Recovery, Recycling, & Recharging Unit SAFETY DEFINITIONS: Follow all WARNING, CAUTION, and NOTE messages in this manual.
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
This equipment has been certified by ITS/ETL to meet or excees SAE J1990 and J1991 for AR512 series and SAE J2099 and J2210 for AR500 series
MOBILE REFRIGERANT RECOVERY/RECYCLING SYSTEM MODELS AR500 AR512 SERIES TO BE OPERATED BY QUALIFIED PERSONNEL ONLY! This equipment has been certified by ITS/ETL to meet or excees SAE J1990 and J1991 for
Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop
Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop ACS 600, 601, 650: Air conditioning service units from Bosch u ACS 600 even the entry model is fully automatic u ACS
AUTOMOTIVE AIR CONDITIONING
3rd Edition 3rd Edition Resources available For the instructor Register online at: www.cengagebrain.com for the study tools that come with your textbook! Companion website: includes weblinks and downloadable
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Elements Elements describe the essential outcomes.
AURETU005 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. Retrofit and modify air conditioning and HVAC systems This unit describes the performance outcomes
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS
KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS THE STANDARD IN INFORMATION, EQUIPMENT AND DIAGNOSTICS SYSTEMS h t t p : / / d i a g n o s t i c s. s n a p o n. c o. u k KOOLKARE INTRODUCTION
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR INTRODUCTION The Cirro MK 3 is a fully professional mist generator for producing sufficient airborne reflection particles to enable effect lighting to
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Operating instructions Platform/floor scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN
Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system
AURETU004 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system 2. Diagnose air conditioning and
National- Spencer Inc.
9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Instructional & Operating Manual
Instructional & Operating Manual For CoolFreeze Series Portable Refrigerators/Freezers CF-18, CF-25, CF-35, CF-40, CF-50, CF-80, CF-110 WAECO USA Clinton, CT www.waecousa.com ! Safety indications in the
Druck PV 62x pneumatic/hydraulic pressure stations
GE Sensing & Inspection Technologies Druck PV 6x pneumatic/hydraulic pressure stations safety and quick reference guide - K08 A. PV 6: Pneumatic pressure station (Figure A.) -90 mbar to 0 bar (-3. to 300
Instruction Manual. Window Wiper AFW900. (Read carefully before use)
Instruction Manual Window Wiper AFW900 (Read carefully before use) When using electrical appliances, basic precautions should always be followed, including the fact READ ALL INSTRUCTIONS IN THIS MANUAL
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
VALUE-100 A/C Service Station User s Manual INDEX
INDEX INTRODUCTION...1 CARE OF THE MANUAL...1 WARRANTY...1 GENERAL INFORMATION...2 END-OF-LIFE...2 SAFETY RULES...2 PRECAUTIONS FOR HANDLING AND USE OF REFRIGERANT FLUIDS...3 PRINCIPLES OF OPERATION...3
SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24
SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24 OPERATING & MAINTENANCE INSTRUCTIONS 1205 PARTS & SERVICE For Spare Parts and Service,please contact your nearest dealer, or CLARKE International,
Flushing and Cleaning the A/C System
Flushing and Cleaning the A/C System Once an AC system has been contaminated or has suffered a failure, the most important part of the AC service to restore the cooling performance to the system = FLUSHING
Online UPS. PowerWalker VFI 1000R/1U
Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as
ROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
OPERATOR MANUAL. Automotive Air-Conditioning Service Equipment WOW! COOLIUS 2700 BT
OPERATOR MANUAL Automotive Air-Conditioning Service Equipment WOW! COOLIUS 2700 BT 2117_ENG / Version:10/03/2011 This equipment has been extensively researched, designed and developed with the prime objective
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual
Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6 User s manual Index Safety Warnings... 2 1 Introduction... 3 2 General Characteristics... 4 3 Receipt and site selection... 4 4 EXTERNAL
Recovery/ Recycling/ Recharging Unit
Recovery/ Recycling/ Recharging Unit Operating Manual Manual de Operación Manuel d utilisation Model 17800B/17801B Recovery/Recycling/Recharging Unit for Multiple Refrigerants...1 Modelo 17800B/17801B
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
Quick Start Guide Vodafone Business Connect
Quick Start Guide Vodafone Business Connect Safety instructions Read the following instructions carefully. Failure to comply with these instructions can be dangerous and/or illegal. You are solely responsible
USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
REGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
AC Service Equipment ACE 21 EXPERT. Fully automatic service station. R-1234yf refrigerant. Made in Germany
AC Service Equipment ACE 21 EXPERT Fully automatic service station R-1234yf refrigerant Made in Germany The new generation of air conditioning service equipment: Robust. Environment-friendly. Fully automatic.
PC1131 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL
INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL 15-LITER, 20-LITER, 35-LITER, 45-LITER, 60-LITER & 100-LITER SECTION 1 Basic Operation SECTION 2 Cleaning and Storing SECTION 3 Basic Trouble
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors
European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for
Register your product and get support at. www.philips.com/welcome AS111. User manual
Register your product and get support at www.philips.com/welcome AS111 User manual Contents 1 Important 4 Safety 4 English 2 Your docking speaker for AndroidTM 5 Introduction 5 What's in the box 5 Overview
MIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
OWNERS MANUAL FOR CORDLESS INFLATOR AIR260
OWNERS MANUAL FOR CORDLESS INFLATOR AIR260 POWER SUPPLY OUTLET: AIR OUTPUT: BATTERY: RECHARGING TIME: WEIGHT: DIMENSIONS: FUSE: LIGHT BULB: SPECIFICATIONS DC 12V 15 AMP 180W MAX 260 PSI MAX PRESSURE SEALED
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information
Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
Leak Detection System
Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input
WIKA INSTRUMENT CORPORATION
WIKA INSTRUMENT CORPORATION Instruction Manual GAUGE PRESSURE INDICATOR Series 1500 Series 1000 Series 300 WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville, GA 30043 1-888-945-2872 http://www.wika.com
CC145. Air Conditioning System. Operation Manual. CC145 Compact Cooler 4/2013 P.N. 10000034A
Air Conditioning System Operation Manual CC145 Compact Cooler 4/2013 P.N. 10000034A To receive the best performance from the air conditioning system, we suggest carefully reading this manual before operating
UK s best selling phone brand. User Guide. BT Big Button 200 Corded Phone
UK s best selling phone brand User Guide BT Big Button 200 Corded Phone 2 Welcome. to your BT Big Button 200 telephone Large buttons for easy, accurate and more comfortable dialling Large display to assist
Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test
APTA STANDARDS DEVELOPMENT PROGRAM RECOMMENDED PRACTICE American Public Transportation Association 1666 K Street, NW, Washington, DC, 20006-1215 APTA BTS-BMT-RP-001-10 Approved October, 2010 APTA Bus Maintenance
Ultrasonic support removal tank
Ultrasonic support removal tank User guide and safety manual See inside for use and safety information. The Ultrasonic support removal tank automatically removes PLA support material from a printed ABS
A/C refrigerant system, overview
Page 1 of 19 87-18 A/C refrigerant system, overview A/C refrigerant system, identification Typical A/C refrigerant system with expansion valve and receiver drier 1 - Evaporator 2 - Expansion valve 3 -
Operating instructions in the back. www.blackanddecker.co.uk PD1020L
Operating instructions in the back www.blackanddecker.co.uk PD1020L 2 ENGLISH (Original instructions) Intended use Your Black & Decker Dustbuster handheld vacuum cleaner has been designed for vacuum cleaning
PC1130 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
PORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION
US Installation Manual Smappee Monitor
US Installation Manual Smappee Monitor Version 1.3 English, US, version 1.3, revision 23, as of October 23, 2014, 2013 Smappee NV. All rights reserved. Specifications are subject to change without notice.
Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
GENANO 4500 MEDICAL AIR PURIFICATION DEVICE
GENANO AIR PURIFICATION TECHNOLOGY GENANO 4500 MEDICAL AIR PURIFICATION DEVICE OPERATING INSTRUCTION 1 GENANO LTD Kimmeltie 3 FI- 02110 Espoo, Finland Tel + 358 9 7743 870 Fax + 358 9 7533 130 www.genano.fi
Model 2128 AIR COMPRESSOR PUMP Operating Instructions
Model 8 AIR COMPRESSOR PUMP Operating Instructions Assembly of pump Connection to cylinder and charging ) Connect the air hose to the air cylinder and tighten with spanner. Do not over tighten. Note; the
