MagneW 3000 PLUS Flowmeter for Open Channel
|
|
|
- Cecilia Walton
- 10 years ago
- Views:
Transcription
1 MagneW 3000 PLUS Flowmeter for Open Channel Wastewater treatment application Yamatake Corporation October 2002 MagneW 3000 PLUS Open Channel type 1
2 Contents Environmental protection ISO Regulation for preventing Water Pollution (Japan, 1978) Total amount of wastewater restriction Monitoring total amount of wastewater Wastewater measurement Problems of wastewater flow measurement Yamatake Solution Field trial in Japan Exclusively certified by Japan Sewage Works Agency October 2002 MagneW 3000 PLUS Open Channel type 2
3 A. Environmental protection Environmental protection: World-wide tendency 1. ISO ISO requires ISO registered manufactures to implement Environment Management System to secure environment The following continuous activities are governed by ISO Policy, 4.3 Plan, 4.4 Do, 4.5 Check, 4.6 Action 4.2 : Requires to meet regulations for wastes Continuous monitoring: Need continuous monitoring of factors which may affect environment. October 2002 MagneW 3000 PLUS Open Channel type 3
4 A. Environmental protection Environmental protection: World-wide tendency 2. Regulation for Wastewater Regulation for preventing Water Pollution in Japan (1978) Total amount restriction Design Guidelines for Sewage Treatment Plants in Singapore issued by PUB (2000). ( Code of Practice on Sewerage and Sanitary Works, article 2.3.8) PUB: Public Utilities Board (Sewerage Department) c) Effluent limitations guidelines by EPA in the U.S.A. (2000) EPA: Environmental Protection Agency Restriction of Discharge of pollutants into waters d) Cluster rule (1998) Restriction of discharging pollutants for Pulp & Paper industry Restrict Wastes/pollutant October 2002 MagneW 3000 PLUS Open Channel type 4
5 B. Monitoring total amount of wastewater Environmental Protection requires restriction of pollutants in wastewater. Two factors to be controlled; 1. Quality of water (water analysis) 2. Total amount of wastewater Regulation Needs to monitor/control total amount of wastewater October 2002 MagneW 3000 PLUS Open Channel type 5
6 C. Wastewater measurement 1.Most of wastewater flows in open channel. 2.Weir or partial flume with level transmitter is mainly used for open channel flow measurement. October 2002 MagneW 3000 PLUS Open Channel type 6
7 D. Problems of wastewater flow measurement 1. Parshall flume flowmeter (with ultrasonic level transmitter) (1)Installation cost is expensive. (2)Low accuracy: +/- 2~5% FS Especially when flow rate is low. (3)Choppy wave causes error. (4)Output is not linear. (5)Minimum sensing flow rate:0.72m3/h October 2002 MagneW 3000 PLUS Open Channel type 7
8 D. Problems of wastewater flow measurement 2. Weir type flowmeter (with ultrasonic level transmitter) (1)Installation cost is not expensive. (2)Low accuracy: +/- 3~5% FS Especially when flow rate is low. (3)Choppy wave causes error. (4)Output is not linear. (5)Minimum sensing level: 5cm October 2002 MagneW 3000 PLUS Open Channel type 8
9 E. Yamatake solution Magnetic flowmeter for open channel (1)Installation cost is not expensive. (2)Higher accuracy: +/- 1% FS Accurate even though flow rate is low. (3)Choppy wave never causes error. (4)Output is linear. (From 0~100%) (5)Minimum sensing velocity: 0m/s 2Q Gate Detector Dummy October 2002 MagneW 3000 PLUS Open Channel type 9
10 E. Yamatake solution Magnetic flowmeter for open channel Additional features (1)Easy installation (2)Maintenance Free (3)Accurate large flow rate measurement 2Q Gate Detector Dummy October 2002 MagneW 3000 PLUS Open Channel type 10
11 E. Yamatake solution Magnetic flowmeter for open channel 1.Easy installation Offers lower installation cost. No piping is required. Installed in the open channel Installed at intake end of channel Installed in the pit Installed at discharge end channel Installed in the discharge tube Installed in the prefabrication sewage disposal plant October 2002 MagneW 3000 PLUS Open Channel type 11
12 E. Yamatake solution 2.Maintenance free (1)All welded plastic housing structure. = provides perfect seal. (2)The detector has no moving parts. Offers long life. 30 years. October 2002 MagneW 3000 PLUS Open Channel type 12
13 E. Yamatake solution 3.Accurate large flow rate measurement Installation of low cost dummies for increasing flow rate. NNK detector Dummy flowtube No coil unit and electrode Q 2Q 3Q Gate Gate Gate Detector Dummy Dummy: 9 units max. October 2002 MagneW 3000 PLUS Open Channel type 13
14 F. Field trial in Japan Comparison test with V-Notch weir flowmeter Field trial at Tagi Sewage Works in Shimane prefecture. Output was compared with the reference meter. Reference meter Reference meter V-Notch weir meter Yamatake Open channel type magflow meter NNK October 2002 MagneW 3000 PLUS Open Channel type 14
15 Test result F. Field trial in Japan Weir type flowmeter -50% error at low flow rate. Not sensitive at low flow rate. MagneW PLUS NNK Open channel type -1% error. Output from 0%. October 2002 MagneW 3000 PLUS Open Channel type 15
16 G. Exclusively certified products for wastewater treatment in Japan As a result of the field trial, Yamatake MagneW PLUS NNK is exclusively certified by Japan Sewage Works Agency. October 2002 MagneW 3000 PLUS Open Channel type 16
Smart Electromagnetic Flowmeter Open channel Flowmeter Detector
Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow
713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the
Configuring the HydroRanger 200 to measure open channel flow. Specific parameter setting to configure the following primary measurement devices:
Flow Application Configuration AG040308 Configuring the HydroRanger 200 to measure open channel flow Objective: Specific parameter setting to configure the following primary measurement devices: exponential
Flow Like An Egyptian: The Basics of Open channel flow
Flow Like An Egyptian: The Basics of Open channel flow Walt Boyes,as ISA Life Fellow, Fellow of InstMC, Chartered Measurement and Control Technologist, Editor of Control and ControlGlobal.com and principal
Open channel & partially filled pipe Ultrasonic flow meters
Open channel & partially filled pipe Ultrasonic flow meters SUITABLE FOR PARTIALLY FILLED PIPES AND OPEN CHANNEL FAMOUS PROFESIONAL ULTRASONIC FLOWMETERS MANUFACTURER, ADVANCED TECHNOLOGY, SERIES PARTIALLY
Tracking the Flow: Meeting the Challenge of Open- Channel Flow Measurement in Municipal Applications
Tracking the Flow: Meeting the Challenge of Open- Channel Flow Measurement in Municipal Applications By Jeff Smith Source: Primary Flow Signal, Inc. Open channels can be tough to measure but careful attention
Flow Measurement Calibration and Measurement
Calibration and Measurement Flow Measurement Flow measurement for agricultural irrigation delivery can be accomplished with four general approaches. These categories are generalized below. I. Standard
Open Channel & Partially Filled Pipe Ultrasonic Flow Meters
Open Channel & Partially Filled Pipe Ultrasonic Flow Meters DYNAMETERS series DMDF-OP has three types as below: DMDF-OP-A for partially filled pipe application; DMDF-OP-B for partially filled pipe, channel
6. FLOW MEASUREMENT. A. Evaluation of Permittee's Flow Measurement
6. FLOW MEASUREMENT Contents Page A. Evaluation of Permittee's Objectives and Requirements... 6-1 Evaluation of Facility-Installed Flow Devices and Data... 6-1 Evaluation of Permittee Data Handling and
Mobrey open channel flow measurement systems
Technical specification sheet IP2039 October 2008 Level Mobrey open channel flow measurement systems Comprising: MCU Flow log datalogging control unit MSP900** Ultrasonic level transmitter Mobrey MCU/MSP
PART E WATER AND WASTEWATER SAMPLING. Her Majesty the Queen in Right of the Province of British Columbia 2003 All Rights Reserved
PART E WATER AND WASTEWATER SAMPLING Her Majesty the Queen in Right of the Province of British Columbia 2003 All Rights Reserved EFFLUENT FLOW MEASUREMENT Her Majesty the Queen in Right of the Province
WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
MONITORING AND MODEL CALIBRATION FOR THE SEWER NETWORK IN OSLO
MONITORING AND MODEL CALIBRATION FOR THE SEWER NETWORK IN OSLO Authors: Ulf E. Roysted 1, Marit Melhuus 1 and Geir J. Lindholm 2 1. Oslo Water and Sewage Works(VAV), Herslebs gate 5, N-0561 Oslo e-mail:
Module 9: Basics of Pumps and Hydraulics Instructor Guide
Module 9: Basics of Pumps and Hydraulics Instructor Guide Activities for Unit 1 Basic Hydraulics Activity 1.1: Convert 45 psi to feet of head. 45 psis x 1 ft. = 103.8 ft 0.433 psi Activity 1.2: Determine
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Istat experience on surveying water statistics: the Water Survey System questionnaires
STATISTICAL COMMISSION and ECONOMIC COMMISSION FOR EUROPE CONFERENCE OF EUROPEAN STATISTICIANS EUROSTAT COMMISSION OF THE EUROPEAN COMMUNITIES EUROSTAT Joint ECE/Eurostat Work Session on Methodological
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
OPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
ELECTROMAGNETIC FLOWMETER COMPACT
R ELECTROMAGNETIC FLOWMETER COMPACT For conductivit Liquids MIK frequency-, switching-, analog otput digital plug on display Range from liquids, acids and caustic solutions:0.01-0.5...35-7000l/min Accuracy:
QUESTIONNAIRE TO ASSIST PREPARATION FOR AN ISO 14001 AUDIT
Questionnaire to prepare for a Certification Audit for Environmental Management Systems (EMS) 0.05.2010 of 9 1 General Details With the help of this questionnaire you can provide a detailed description
Equipment for Engineering Education
Equipment for Engineering Education Instruction Manual Venturi Flume G.U.N.T. Gerätebau GmbH Fahrenberg 4 D-885 Barsbüttel Germany Phone: ++49 (40) 670854.0 Fax: ++49 (40) 670854.4 E-mail: [email protected]
Centre d expertise en analyse environnementale du Québec
Centre d expertise en analyse environnementale du Québec Sampling Guide for Environmental Analysis BOOKLET 7 FLOW MEASUREMENT METHODS IN OPEN CHANNELS English Version of The Original Publishing EDITION
Steven R. McManus Environmental Product Support Teledyne Isco
Steven R. McManus Environmental Product Support Teledyne Isco Flow Measurement Applications and Technologies. Methods of flow measurement Technologies of flow measurement Flow Rate Applications Channel
1 WATERFLUX - Comparisonon COO 2010-08-17. Rectangular Magmeter in water applications
1 WATERFLUX - Comparisonon COO 2010-08-17 Rectangular Magmeter in water applications Jef Neven KROHNE WATERMETERS $3000 EMF Price C&I (mechanical) water meters Residential water meters $30 Water Metering
Flow Measurement Options for Pipeline and Open Channel Flow
Flow Measurement Options for Pipeline and Open Channel Flow October 2013 Presented by Molly Skorpik - 2013 Montana Association of Dam and Canal Systems Conference Irrigation Training and Research Center
Open Channel Flow Measurement Weirs and Flumes
Open Channel Flow Measurement Weirs and Flumes by Harlan H. Bengtson, PhD, P.E. 1. Introduction Your Course Title Here Measuring the flow rate of water in an open channel typically involves some type of
The World Market for Thermal Flowmeters
Overview Published: October 2009 www.flowthermal.com 2 27 Water Street Wakefield, MA 01880 United States [1] 781-245-3200 [1] 781-224-7552 (fax) www.flowresearch.com Flow Research has completed a new market
DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: 0.05 40376 m 3 /h. Accuracy: ± 0.3% of reading ± 0.
Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: 0.05 40376 m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : -20... +150 C O
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
HYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long
HYDRAULICS H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long 1. General The series of channels H91.8D has been designed by Didacta Italia to study the hydrodynamic
Electromagnetic Flow Meter
Electromagnetic Flow Meter Description The EL 2200 series of electromagnetic sensors represent the state of the art for the accurate measurement for water cycle and process applications. Flow meters are
Mobrey open channel flow measurement systems
Specification sheet IP2039 Sept 2005 Level Mobrey open channel flow measurement systems Comprising : MCU Flow log datalogging control unit MSP900** Ultrasonic level transmitter Mobrey Measurement MCU/MSP
PACKAGE WASTEWATER TREATMENT PLANT SPECIFICATIONS 3,000 GPD 100,000 GPD PLANTS
PACKAGE WASTEWATER TREATMENT PLANT SPECIFICATIONS 3,000 GPD 100,000 GPD PLANTS Pollution Control Systems, Inc. (PCS) is pleased to provide the following equipment specifications for your consideration.
CASE STUDY Hanjiang Dafu Shoe Company & Putian Hanjiang Shoe Company
CASE STUDY Working with Local Government to Lower Pollution Control Costs & to Improve Regional Environmental Clean-up Infrastructure Hanjiang Dafu Shoe Company & Putian Hanjiang Shoe Company Case Study
Gertrudys B. Adkins, Ph.D. Division of Water Rights 2006
FLOW MEASUREMENT DEVICES By Gertrudys B. Adkins, Ph.D. Division of Water Rights 2006 TABLE OF CONTENT INTRODUCTION...1 FLOW MEASUREMENT DEVICES...1 FLOW MEASUREMENT BASICS...2 OPEN CHANNEL FLOW METHODS...3
...Eq(11.6) The energy loss in the jump is dependent on the two depths y 1 and y 2 3 = E =...Eq(11.7)
. Open Channel Flow Contd.5 Hydraulic Jump A hydraulic jump occurs when water in an open channel is flowing supercritical and is slowed by a deepening of the channel or obstruction in the channel. The
OPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
Minimum Requirements for the Self-Monitoring of Flow
Minimum Requirements for the Self-Monitoring of Flow Environment Agency Version 4.0 August 2014 Foreword We set up our Monitoring Certification Scheme (MCERTS) to provide a framework of standards you
FLUXUS Energy. Manage energy effectively using non-invasive measuring technology. Heat usage, chilled flows and compressed air flow rate
Manage energy effectively using non-invasive measuring technology FLUXUS Energy Heat usage, chilled flows and compressed air flow rate Heating and air-conditioning technology Non-invasive power of thermal
Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics
THORTO Leading Pure Water nalytics Economical Paddlewheel Hi-Purity PF Ultrasonic Vortex Insertion-type Vortex Convenient, Reliable and Economical Flow Measurement Paddlewheel Reliable and Economical Inline
Instrumentation for remote-monitoring and telemetry solutions in environmental sector: sensors - data loggers - web services
Technology Offer Instrumentation for remote-monitoring and telemetry solutions in environmental sector: sensors - data loggers - web services Summary A French SME designs and manufactures wireless instrumentation
Flow Measurement. Larry Schwankl. Irriga0on Specialist, UC Coopera0ve Extension 559-646- 6569 [email protected] hep://ucanr.
Flow Measurement Larry Schwankl Irriga0on Specialist, UC Coopera0ve Extension 559-646- 6569 [email protected] hep://ucanr.org/schwankl Flow Measurement - Background Flow in a pipe: Flow Measurement -
PACKAGE TERTIARY FILTER SYSTEM SPECIFICATIONS MODELS TF-2-6-C THROUGH TF-2-35-C
PACKAGE TERTIARY FILTER SYSTEM SPECIFICATIONS MODELS TF-2-6-C THROUGH TF-2-35-C Pollution Control Systems Inc. (PCS) is pleased to provide the following equipment specifications for your consideration.
Overview of the state of the art heat measurement technologies for larger solar thermal systems
Overview of the state of the art heat measurement technologies for larger solar thermal systems Overview of the state of the art heat measurement technologies for larger solar thermal systems... 1 Introduction...
PRESENT ISSUES FOR CENTRE DE LA MANCHE DISPOSAL FACILITY
PRESENT ISSUES FOR CENTRE DE LA MANCHE DISPOSAL FACILITY M. DUTZER, J.P. VERVIALLE, P. CHARTON Andra - Agence Nationale pour la Gestion des Déchets Radioactifs 1-7 rue Jean Monnet, 92298 Châtenay-Malabry
The Japan Society of Mechanical Engineers C 2010
The Japan Society of Mechanical Engineers C 2010 The Japan Society of Mechanical Engineers 2010 C The Japan Society of Mechanical Engineers 2010 C The Japan Society of Mechanical Engineers C 2010 The Japan
On Site Treatment Systems
On Site Treatment Systems Introduction In cases where houses require to be located in the countryside,(i.e. where no sewerage is available),it is necessary to provide a specific on-site treatment system
Complete Solutions for On-Site Wastewater Management
Complete Solutions for On-Site Wastewater Management System 1 Collection System 2 Treatment System 3 Disposal State-of-the-Art, Environmentally Conscious Wastewater Solutions for Developers. Delta Environmental
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering
How To Use A Corona Mdi 110
CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
Monterey Regional Water Pollution Control Agency. Sewer System Management Plan
Monterey Regional Water Pollution Control Agency Sewer System Management Plan March 31, 2013 Sewer System Management Plan Introduction I. Goals II. Organization III. Legal Authority IV. Operation and Maintenance
SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.
SEPTIC SYSTEMS Who Has A Septic System? Approximately 30 percent of Connecticut s population is served by on-site subsurface sewage disposal systems (a.k.a. septic systems). This means a large percentage
On-site Treatmentt for Domestic Wastewater in Thailand Suwanna. K. Boontanon Mahidol Univ. 2
WEPA International Workshop 2013 Cambodia On-site Treatment for Domestic Wastewater in Thailand Suwanna Kitpati Boontanon Assistant Professor, Faculty of Engineering Mahidol University February 18, 2013
Training programme on flow measurements
WMO / OMM Autorite du Bassin du Niger Niger-HYCOS and Volta-HYCOS Projects Training programme on flow measurements 2 nd part : Flow measurement techniques Flow measurements and calculations Definitions
GEC s Survey and Review on Water Footprint from Japanese Perspective
GEC s Survey and Review on Water Footprint from Japanese Perspective Makoto Fujita Global Environment Centre (GEC) Osaka, JAPAN Background In Japan, a lot of water from overseas is used through imported
Flow Sensors. - mass flow rate - volume flow rate - velocity. - stream line parabolic velocity profile - turbulent vortices. Methods of measurement
Flow Sensors Flow - mass flow rate - volume flow rate - velocity Types of flow - stream line parabolic velocity profile - turbulent vortices Methods of measurement - direct: positive displacement (batch
Understanding the Flo-Dar Flow Measuring System
Understanding the Flo-Dar Flow Measuring System Independent tests verify non-contact flowmeter is highly accurate under both open channel and surcharge conditions TM Flo-Dar is the only non-contact open
Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across
Flow Pulse Unique, non-invasive clamp-on flow monitor Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across
ngenieros Ingenieros Asociados De Control S.L.
ngenieros sociados de ontrol 1 Company founded in 1985 to serve commercial and technical assistance in the fields of instrumentation, control and installation for all types of industries. We offer top
PRSENTATION ON DRAINAGE SYSTEM DELHI 25.07.2014 EAST DELHI MUNICIPAL CORPORATION
PRSENTATION ON DRAINAGE SYSTEM OF DELHI EAST DELHI MUNICIPAL CORPORATION 25.07.2014 MAP OF DELHI SHOWING MCD s, NDMC & DCB ABOUT DELHI DELHI MANIFESTS UNCONTROLLED URBANISATION POPULATION INDUSTRIALISATION
Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers
Flow and Flow rate. Laminar and Turbulent flow Laminar flow: smooth, orderly and regular Mechanical sensors have inertia, which can integrate out small variations due to turbulence Turbulent flow: chaotic
Urban Environmental Management in Singapore. Jothieswaran P Chief Engineer Pollution Control Department National Environment Agency
Urban Environmental Management in Singapore Jothieswaran P Chief Engineer Pollution Control Department National Environment Agency Introduction City state comprising a main island and some islets Land
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
According to L. R. S. 48:385, any discharge to a state highway ditch, cross ditch, or right-of-way shall require approval from: AND
To: Prospective Applicants for the Automotive Dealership, Paint & Body Shop, Automotive Repair Facilities, Motorcycle Dealership and Recreational Vehicle Dealership General Permit Attached is an Automotive
Sustainable solu&ons to wastewater systems in the face of sea level rise Chris&an Nilsen, PE Stanford University Research and Industrial Liaison
Re- inven'ng the Na'on s Urban Water Infrastructure [ReNUWIt] Sustainable solu&ons to wastewater systems in the face of sea level rise Chris&an Nilsen, PE Stanford University Research and Industrial Liaison
CHAPTER 15 MUNICIPAL SEPARATE STORM SEWER SYSTEM PROGRAM REQUIREMENTS
CHAPTER 15 MUNICIPAL SEPARATE STORM SEWER SYSTEM PROGRAM REQUIREMENTS 15.1 INTRODUCTION In accordance with Section 402 (p) of the Clean Water Act, the National Pollutant Discharge Elimination System (NPDES)
Series DFMT Digital Paddlewheel Flowmeter
Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous
Sewer servicing and integrated resource management
Sewer servicing and integrated resource management Gabriola Village Center Ian Ralston Eng.L. 1 Outline Sewage systems, servicing Regulatory context Decentralized concept Management Treatment techniques
PORTABLE FLOW METER KITS TDS-100H
Transit Time Flow Meters TT-TDS-100H-HS ECEFast offers amazing prices on Transit Time Flow Meter portable kits. We are buying from the manufacturer who supplies 60% of the Chinese market and the majority
MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE CHAPTER II SEWAGE AND WASTES SECTION 8
MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE CHAPTER II SEWAGE AND WASTES SECTION 8 ONSITE WASTEWATER TREATMENT FACILITIES REGULATION 1. Definitions a. Aggregate means a clean graded hard rock, volcanic rock,
DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.
GE Sensing & Inspection Technologies DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range Applications The DigitalFlow GF868 flowmeter is a complete ultrasonic
SILICON VALLEY CLEAN WATER. May 2015
SILICON VALLEY CLEAN WATER May 2015 Slug Discharge Control and Spill Containment Guidelines This document was revised and used with the permission of the Los Angeles County Sanitation District, Industrial
CEE 370 Fall 2015. Laboratory #3 Open Channel Flow
CEE 70 Fall 015 Laboratory # Open Channel Flow Objective: The objective of this experiment is to measure the flow of fluid through open channels using a V-notch weir and a hydraulic jump. Introduction:
ABB Flowmeters Review of industrial processing flowmeters
White paper ABB Flowmeters Review of industrial processing flowmeters Understanding flowmeters and their pros and cons By Ron DiGiacomo, ABB Measurement Products One of the most critical measurements in
Know the Flow. Flowmetering Training Manual
Know the Flow Flowmetering Training Manual Acknowledgments ANCID and its member organisations National Program for Irrigation Research and Development Goulburn Murray Water Training Centre Manly Hydraulics
Peeling the Onion of Meter Accuracy Two Steps to Evaluating Flow Meter Data
Peeling the Onion of Meter Accuracy Two Steps to Evaluating Flow Meter Data ABSTRACT Patrick L. Stevens, PE ADS Environmental Services 9 S. Cloverdale St., Suite B Seattle, WA 988 It is a natural desire
CHAPTER 10 TRAPS AND INTERCEPTORS
CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved
Practice Tests Answer Keys
Practice Tests Answer Keys COURSE OUTLINE: Module # Name Practice Test included Module 1: Basic Math Refresher Module 2: Fractions, Decimals and Percents Module 3: Measurement Conversions Module 4: Linear,
Outline. Objective. Overview Sanitary Drainage System. Design. Materials
1 Outline Objective Overview Sanitary Drainage System Standard References Design Materials 2 SAWEA) Workshop 2010 Objective Address the minimum requirements for Sanitary Sewers System that are located
SDX Submersible Depth Transmitter User Manual
SDX Submersible Depth Transmitter User Manual January 2011 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.
Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS
Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS The evolution continues in decentralised wastewater technology... The Process Decentralised wastewater treatment systems are defined
MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT
Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public
Reliability Accuracy Performance
FCI flow switch guide Reliability Accuracy Performance eliability, accuracy and performance are the key product features required by FCI customers for their flow, level and temperature switch applications.
FLOW CONDITIONER DESIGN FOR IMPROVING OPEN CHANNEL FLOW MEASUREMENT ACCURACY FROM A SONTEK ARGONAUT-SW
FLOW CONDITIONER DESIGN FOR IMPROVING OPEN CHANNEL FLOW MEASUREMENT ACCURACY FROM A SONTEK ARGONAUT-SW Daniel J. Howes, P.E. 1 Charles M. Burt, Ph.D., P.E. 2 Brett F. Sanders, Ph.D. 3 ABSTRACT Acoustic
Type of Sewer Systems. Solomon Seyoum
Type of Sewer Systems Solomon Seyoum 0 Learning objectives Upon completion of this lecture, the participants will be able to differentiate between types of sewer systems and discuss different aspects of
Glen Hills Area: Septic System and Public Sewer Q & A Information Sheet Page 1
Glen Hills Area: Septic System and Public Sewer Q & A Information Sheet Page 1 The Montgomery County Dept. of Environmental Protection, in cooperation with the Dept. of Permitting Services and the Washington
DigitalFlow GF868 Panametrics Ultrasonic Flare Gas Mass Flowmeter. GE Sensing. Features. Applications
Applications Features The DigitalFlow GF868 flowmeter is a complete ultrasonic flow metering system for: Flare gas Track down or prevent losses from leakage with positive material identification Account
2006 Standard Application Processing Time. 10 months. 14 months
Air and Radiation Management Administration General Permit to Construct - without expanded public review Air Quality Permit to Construct - with expanded public review but limited public interest 11 months
City of Bakersfield Public Works Department Sewer System Management Plan December 2014
City of Bakersfield Public Works Department Sewer System Management Plan December 2014 C:\Users\hmayberry\Desktop\SEWER SYSTEM MANAGEMENT PLAN 2014.doc 1 Sewer System Management Plan Index: Section 1 Goals
Repairs Made With Under Pressure Installations Can Offer Reduced Risks And Expenses
Repairs Made With Under Pressure Installations Can Offer Reduced Risks And Expenses They also give the community a built-in re-entry system for future monitoring and repair. BY BRETT HANES According to
Mass Flow Meters & Controllers
HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2% of Full Scale) 0-5 VDC or 4-20
Boiler Control Solution. Boiler Control Solution. Instruments and Solution for Automatic Boiler Control LF3BUSS02-00EN. www.yokogawa.
Boiler Control Boiler Control Instruments and for Automatic Boiler Control LF3BUSS02-00EN www.yokogawa.com Best for Automatic Boiler C Sensors and controllers for the efficiency and environmental performance