EuroPHit. Outlines for training modules For Airtightness Installation and Measurement
|
|
|
- Clare Harper
- 10 years ago
- Views:
Transcription
1 EuroPHit Outlines for training modules For Airtightness Installation and Measurement Michael McCarthy Passive House Academy Dublin, Irleand
2 The EuroPHit Project With the EnerPHit Standard as the goal and Passive House principles as the basis, EuroPHit applies knowledge on deep energy retrofits to the oft-overlooked yet critical area of step-bystep refurbishments
3 Airtightness Installation and Measurement Course Overview Module Title Time Description 1. Introduction to Airtightness 90 mins Introduce the fundamental building physics of AT, the role AT plays in the PH Standard, definitions, consequences of poor AT and suitable materials. Also describe the correlation between AT level and Ventilation requirements 2. Airtightness Detailing 90 mins Study of Exemplary AT Details in model/drawing form, analyse AT site installations, sketching exercises 3a. AT Installation Demonstration 60 mins Practical Hands-On demonstration in the lab showing exemplar AT installation techniques and how to deal with a variety of challenging connection details
4 Airtightness Installation and Measurement Course Overview Module Title Time Description 3b. Hands-On AT Installation 120 mins Trainees practice the techniques demonstrated previously using lab based models in a controlled environment where the focus is on quality of installation 4a. Airtightness Testing EN mins Define the requirements, testing procedures and calculations according to EN Introduce methods and techniques for leak detection testing and describe the additional PHI testing requirements and standards 4b. AT Testing Software 45 mins Demonstrate how to use Blower Door Testing software and highlight the critical issues for both large and small building types (new and existing)
5 Airtightness Installation and Measurement Course Overview Module Title Time Description 5. Blower Door Test Demonstration 105 mins Demonstrate a full Blower Door Test on a sample AT mini house including climate condition checks, building preparation, building measurements and calculations, blower door installation, leak detection, full pressurisation and depressurisation tests, software input and results generation 6. Practice Blower Door Testing 120 mins Allow the trainees to practice all of the techniques and elements demonstrated in module 5 under the controlled lab conditions in preparation for the Site Visit and Project
6 Airtightness Installation and Measurement Course Overview Module Title Time Description 7a. AT Site Visit 225 mins Trainees are on site ideally at their chosen project or alternatively at any existing building. A full site Blower Door test is carried out as practiced In Module 6 and all results are retained for later analysis. This element can be carried out as a full class group or in smaller teams 7b. Site Visit Analysis 105 mins Trainees return to the classroom for an analysis session in 4 smaller groups. Each group must analyse the site findings and come up with appropriate solutions so the required n50 can be achieved 7c. Site Visit Presentation 60 mins 15 minute presentation per group to the rest of the class reporting on their findings, analysis of current situation, critical leakage sites and their proposed AT solutions
7 Course Contents In this course we will cover the following topics: Air Leakage in Buildings Definition of Airtightness AT in Passive Houses (New and EnerPHit) Designing and Detailing for Airtightness Materials what to Use and what to Avoid AT and the influence on Ventilation Airtightness on Site practical installation Leak Detection Testing Why and When EN Blower Door Testing to find V 50 Calculation of Airtightness n 50 and q 50 (w 50 and A 50 ) Calculation of n inf, AT influence on SHD and Energy Cost
8 Module 1 - Introduction to Airtightness Common Leakage Areas in Standard Construction
9 Module 1 - Introduction to Airtightness Airtightness Definition Airtightness is the process of eliminating cracks, gaps and holes in the fabric of the building envelope to achieve a measurable standard using specified materials that are durable and long lasting
10 Module 2 Airtightness Detailing Airtightness Detailing
11 Module 3 Airtightness Installation Airtight on Site General A B C D Source: Siga
12 Module 3 Airtightness Installation Airtight on Site Window Inner Corner A B C D E Source: Siga
13 Module 4 Airtightness Testing Methods Airtightness The Standard Air Tightness Testing and Measurement methods are described in: EN (ISO 9972) Thermal Performance of Buildings Determination of Air Permeability of Buildings Fan Pressurization Method Two methods of quantifying Airtightness levels: Method A: Air Changes (Volume) Method B: Air Permeability (Envelope Area) Both methods are used to detect leaks in the building envelope and to determine the airtightness level. The PHI has specified Method Aas the methodology for Passive Houses
14 Module 4 Airtightness Testing Methods Airtightness Reference Pressure As detailed in I.S. EN 13829, a fan is installed into the opening of a window or door with an airtight seal. The airtightness of a building is always (method A and method B) measured with a set differential pressure created between inside and outside using the speed-regulated fan. The reference pressure is: 50 Pascals (Pa) Source: Tip Top Restoration
15 Module 4 Airtightness Testing Methods Airtightness Blower Door Software
16 Modules 5 and 6 Demonstration and Practice Airtightness Testing and Measurement Measurement Blower Door: Used to measure and certify Airtightness level (v50, n50, q50, A50, w50) Source: Retrotec
17 Modules 5 and 6 Demonstration and Practice Airtightness Testing and Measurement
18 Modules 5 and 6 Demonstration and Practice Weather Conditions - Equipment
19 Module 7 Project Airtightness Module 7 Project Airtightness (a) Site Visit and Test (b) Site Visit Analysis and Report (c) Site Visit Presentation
20 Thank you for your attention The sole responsibility for the content of this presentation lies with the authors. It does not necessarily reflect the opinion of the European Union. Neither the EACI nor the European Commission are responsible for any use that may be made of the information contained therein.
How To Design An Hvac Design For A Stick Built Home
LEGALETT HVAC DESIGN FEE SCHEDULE (revised April 17, 2012) Background In the past Legalett has simply supplied warm floors for comfortable living. However, 2012 Building Code changes in Ontario make it
Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades
Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial
Confort 160. Sliding Systems. Sapa Building System
Confort 160 Sliding Systems Sapa Building System Confort 160 is a high performance thermally insulated sliding window system, with a user-friendly slide action. The system, which has an attractive aesthetic
RESNET National Rater Test Study Guide Outline
RESNET National Rater Test Study Guide Outline The RESNET national home energy rating standard spells out a listing of the knowledge base and skills set for Home Energy Ratings. Trainers and Rating Quality
WHAT IS INFRARED (IR) THERMOGRAPHY
WHAT IS INFRARED (IR) THERMOGRAPHY IR Thermography is the technique of producing pictures called from the invisible thermal radiation that objects emit. This is a non-contact means of identifying electrical
THE REYNAERS INSTITUTE
THE REYNAERS INSTITUTE TOGETHER FOR BETTER INTRODUCTION Since the company s creation in 1965, Reynaers Aluminium has been playing a leading role in the construction industry. Its profile systems have evolved
Training Course Catalog
Training Course Catalog Our courses are designed and taught by industry experts who have hands-on experience across the nation, bringing the most current and practical knowledge to our students. With 30
Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects
Makeup Air For Exhaust Systems In Tight Houses Tony Jellen Engineering Projects PA Housing & Land Development Conference February 23, 2012 Effects of Kitchen Ventilation on Residential Dwellings Anthony
Q-Lon foam weatherseal: for PVC, timber and aluminium applications THE WORLDS BEST WEATHERSEAL
Q-Lon foam weatherseal: for PVC, timber and aluminium applications THE WORLDS BEST WEATHERSEAL CONTENTS About Schlegel 3 Q-Lon Profiles PVC doors, windows and roller shutters 6 Timber doors and windows
Center for Energy Education Laboratory
Paper ID #7072 Center for Energy Education Laboratory Dr. Robert Gilbert, Sinclair Community College Robert B. Gilbert, Ph.D., LEED AP, BA, is an Associate Professor of Energy Management Technology, and
Schedule of Work Experience (OJL) and Training considered necessary to develop a skilled and productive worker.
WORK PROCESS SCHEDULE Energy Auditor and Analyst for Residential Retrofit Market (existing homes) O*NET-SOC Code: 13-1199.01 RAPIDS Code: 2005HY Schedule of Work Experience (OJL) and Training considered
Executive Order amending the Executive Order on the Publication of the Danish Building Regulations 2010 (BR10) 1)
Full text Executive Order amending the Executive Order on the Publication of the Danish Building Regulations 2010 (BR10) 1) 1. The following amendments shall be made to Executive Order no. 810 of 28 June
solutions & tips six Wise Energy Guide Building envelope solutions and simple tips AIR SEALING
Wise Energy Guide solutions & tips 32 AIR SEALING Is your house leaking money? six Building envelope solutions and simple tips If your home is like most, the greatest amount of heat loss is from air leakage;
Assessment Methods. 15 th November 2010 Huw Jenkins Simon Lannon
Assessment Methods 15 th November 2010 Huw Jenkins Simon Lannon Assessment Methods Program Country Year Program Country Year 1 R-2000 Canada 1982 12 LEED US 2000 2 P-mark Sweden 1989 13 ECO-Quantum Netherlands
Confort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
Window Installation in Passive Houses ways to achieve superior insulation, airtightness and durability
Window Installation in Passive Houses ways to achieve superior insulation, airtightness and durability Florian Speier Swiss Architect CPHC co-founder, Zola European Windows What makes a window perform?
The first apartment house renovation with Passive House components in Norway
14th International Passive House Conference Dresden, May 28, 2010 Michael Klinski Tor Helge Dokka The first apartment house renovation with Passive House components in Norway 168 flats, onebedrooms (55
Blower Door Testing by David Keefe
Blower Door Testing by David Keefe Diagnose problems in the building envelope with this simple, reliable tool Air flowing in and out of a building can cause lots of problems; in fact, air leakage can account
Company DUOL. Dušan Olaj CEO
Company DUOL Company DUOL has been active on the market since 1992 and throughout this period Duol has successfully attained the position of one of the most significant suppliers of fabric structures.
Rockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
Building Energy Codes 101 October 23, 2013. Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance
Building Energy Codes 101 October 23, 2013 Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance OVERVIEW 1. Introduction 2. Energy Code Development 3. Adoption Process 4. Elements
EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money
EASY$ TIP SHEETS Energy Advice Saving Yukoners Money Quick Links How to check for leaks Draftproofing products Sealants Draft proofing your home Draftproofing can be a cost-effective measure you take to
Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings
Best2 Airtightness of Buildings Session WB6-2 Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings Mario D. Gonçalves, Patenaude-Trempe and Robert Jutras, Air-Ins Introduction
FREQUENTLY ASKED QUESTIONS about HERS and CHEERS Provided by the California Energy Commission Consumer Energy Center
http://www.energy.ca.gov/ FREQUENTLY ASKED QUESTIONS about HERS and CHEERS Provided by the California Energy Commission Consumer Energy Center Relevant Standard The Residential Manual for Compliance with
Ventilation and Air Leakage
building science.com 2008 Building Science Press All rights of reproduction in any form reserved. Ventilation and Air Leakage Research Report - 0303 November-2003 Andrew C. Åsk, PE Abstract: Buildings
Case Study: Low carbon refurbishment of Westborough Primary School
Case Study: Low carbon refurbishment of Westborough Primary School Summary The buildings at Westborough Primary had evolved through a fragmented and piecemeal series of building additions and adaptations
Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice
Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice A truly international certification The Eurovent Certification Programmes are managed by an autonomous
Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure
Basements are Changing John Straube, Ph.D., P.Eng Basements: New & Retrofit Energy Efficient, Durable, Healthy Increasingly used as living space Not a root /coal cellar anymore! High quality space expected
THE IC Y N E N E AD V A N T A G E
THE IC Y N E N E AD V A N T A G E APP L I C A T I O N CA S E ST U D Y : Insulating a Metal Building for Air Sealing/ Energy Efficiency Synopsis: Twice as effective at air sealing versus conventional insulation
Wraptite THE AIRTIGHT AND VAPOUR PERMEABLE MEMBRANE
Wraptite THE AIRTIGHT AND VAPOUR PERMEABLE MEMBRANE The A. Proctor Group Ltd, a familyowned company in its fourth generation, has been providing solutions and products to the construction industry for
Heating, Ventilation, Air Conditioning, Refrigeration Engineering Technology
Heating, Ventilation, Air Conditioning, Refrigeration Engineering Technology Engineering, Math and Physical Sciences Division Room T102, (847) 543-2044 The HVACR program provides instruction in air conditioning,
In the Fall 2002 issue of HHE News I examined
Choosing Replacement Windows 1 For Your Home Mark Pierce In the Fall 2002 issue of HHE News I examined reasons for, and against, replacing older windows with new, energy efficient windows. That article
INFORMED MECHANICAL DESIGN THROUGH TESTED AIR LEAKAGE RATES. Jeff Speert, AIA MAIBC LEED AP
INFORMED MECHANICAL DESIGN THROUGH TESTED AIR LEAKAGE RATES Jeff Speert, AIA MAIBC LEED AP Background Move towards more energy efficient structures Collaborative approach promoted by LEED, 2030 Challenge,
The risk assessment of fire damper installations
The risk assessment of fire damper installations June 2010 Paul White OVERVIEW OVERVIEW The purpose of this presentation is to highlight that fire dampers form a key part of the passive fire protection
Claiming the Passivhaus Standard:
: Technical briefing document Updated March 2015 Acknowledgements This paper was written by Mark Siddall and Nick Grant, with input from the Passivhaus Trust Technical Panel and the Trust s Passivhaus
Enclosing Timber Frames. Panels. Frank Baker Founder, Riverbend Timber Framing and Insulspan
Enclosing Timber Frames with Structural Insulated Panels Frank Baker Founder, Riverbend Timber Framing and Insulspan Outline What are SIPs? Structural advantage of SIPs for timber frames Energy performance
Unified Physical Infrastructure (UPI) Strategies for Thermal Management
Unified Physical Infrastructure (UPI) Strategies for Thermal Management The Importance of Air Sealing Grommets to Improving Smart www.panduit.com WP-04 August 2008 Introduction One of the core issues affecting
THE IMPACT OF ENERGY EFFICIENT REFURBISHMENT ON THE AIRTIGHTNESS IN ENGLISH DWELLINGS
THE IMPACT OF ENERGY EFFICIENT REFURBISHMENT ON THE AIRTIGHTNESS IN ENGLISH DWELLINGS Sung H. Hong 1, Ian Ridley 2, Tadj Oreszczyn 3, The Warm Front Study Group 4 1, 2, 3 Bartlett School of Graduate Studies,
Plaisance 50. Windows and doors. Sapa Building System
Plaisance 50 Windows and doors Sapa Building System Plaisance 50 is a non-thermally broken system for aluminium windows and doors with a building depth. The system offers a wide range of inward and outward
Impact of Infiltration on Heating and Cooling Loads in U.S. Office Buildings
Impact of Infiltration on Heating and Cooling Loads in U.S. Office Buildings 1 Steven J. Emmerich, 1 Andrew K. Persily, and 2 Timothy P. McDowell 1 Building and Fire Research Laboratory, National Institute
Liabilities of Vented Crawl Spaces And Their Impacts on Indoor Air Quality in Southeastern U.S. Homes
Liabilities of Vented Crawl Spaces And Their Impacts on Indoor Air Quality in Southeastern U.S. Homes Jonathan Coulter, Bruce Davis, Cyrus Dastur, Melissa Malkin-Weber and Tracy Dixon Advanced Energy,
Passive Cross Laminated Timber Buildings
Final Report Passive Cross Laminated Timber Buildings Cerbof-project no. 76 Henrik Janols, Mats Rönnelid, Tina Wik, Dalarna University Matias Brännström, Stora Enso Wood Products Håkan Helling, Tommy Lövenvik,
Duct Leakage Testing 101 Frank Spevak The Energy Conservatory Minneapolis, MN
Duct Leakage Testing 101 Frank Spevak The Energy Conservatory Minneapolis, MN Copyright 2011 The Energy Conservatory Minneapolis MN 612-827-1117 Housekeeping If you do not hear anything from your computer
Training course catalog
1 Training course catalog CLEAResult training courses are designed and taught by industry experts with hands-on experience from across the nation, bringing the most current and practical knowledge to our
PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation
PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation INTRODUCTION As the use of spray polyurethane foam (SPF) insulation is increasing in both
Sealing & Bonding Sika solutions for Window Installation
Sealing & Bonding Sika solutions for Window Installation Sika s Comprehensive Fenestration Competence Benefit of our solution Globally, growing requirements to save energy and to utilize natural resources
Avoiding Air Barrier Pitfalls
Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great
Maintenance Matters. Window and Door Replacement
Number 13 Maintenance Matters building maintenance bulletin Window and Door Replacement As part of the ongoing maintenance of your home or multi-unit residential building, windows and doors will eventually
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010 1. Background Class II Type B Biosafety Cabinets (BSCs) are unique laboratory
Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes
Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes Current Status % CO 2 emissions Transport 30% Agriculture 2% Housing
Before You Start an Energy Efficiency Retrofit The Building Envelope
ABOUT YOUR HOUSE Before You Start an Energy Efficiency Retrofit The Building Envelope The building envelope is the outer layer of the building that separates the indoor living space from the outdoor environment,
2015 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY
MINNESOTA ENERGY CODE COMPLIANCE COLLABORATIVE 2015 Minnesota Residential Energy Code (MR 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY (July 15, 2015 Update) Note: The following information contains
Mario D. Gonçalves, Patenaude-Trempe 1 Pierre Gendron, Patenaude-Trempe 2 Tony Colantonio, PWGSC 3. Abstract
Commissioning of Exterior Building Envelopes of Large Buildings for Air Leakage and Resultant Moisture Accumulation using Infrared Thermography and Other Diagnostic Tools Mario D. Gonçalves, Patenaude-Trempe
Plaisance 24. Sliding Systems. Sapa Building System
Plaisance 24 Sliding Systems Sapa Building System Plaisance 24 is Sapa s noninsulated sliding system for windows and doors. Available as one-, two-, three- and fourrail solution. Among its features, there
Using Multiple Routers with TECLOG3 and TEC WiFi Links (1 Linksys EA6900 and 3 TP-Link TL-MR3040)
Using Multiple Routers with TECLOG3 and TEC WiFi Links (1 Linksys EA6900 and 3 TP-Link TL-MR3040) When conducting a multi-fan airtightness test of a commercial building with TECLOG3, you will typically
Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products
Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products 10 reasons for an energy labeling system (1/2) The buildings sector is responsible for a considerable share of final
ECHO System for Basements
ECHO System for Basements Homeowners looking for more space are all too familiar with the cold, damp and dingy basement. Now, the Enclosure Conditioned Housing (ECHO) System TM, winner of the Ottawa-Carleton
Energy Efficiency for the Homeowner
Efficiency for the Homeowner How to Reduce Your Home s Bills October 2009 National Mall Washington, DC A Quick Test Using Efficient Products and Practices Can: A. Make your home more affordable B. Make
ROOFS, SNOW AND ICE DAMS
ROOFS, SNOW AND ICE DAMS The Problem Ice dams are a common roof performance problem in cold climate buildings. Simply put, they are ridges of ice and icicles caused by melt water from further up the roof
DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1
Building Science Bulletin DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1 and IECC Air Leakage Requirements When Tested in Accordance with ASTM E2357
Chapter Seven RESNET Standards
Chapter Seven RESNET Standards 700 RESNET NATIONAL STANDARD FOR HOME ENERGY AUDITS 701 GENERAL PROVISIONS 701.1 Purpose The provisions of this Standard are intended to define a framework for a home energy
Jesse Krivolavek Nebraska Native American Energy Auditors 20214 Veterans Dr Ste. 600, Omaha, NE 68022
Jesse Krivolavek Nebraska Native American Energy Auditors 20214 Veterans Dr Ste. 600, Omaha, NE 68022 HERS Rater HERS Instructor National HERS QA Delegate BPI Building Analyst Energy Star Verifier EPA
IECC Compliance Guide for Homes in Virginia
IECC Compliance Guide for Homes in Virginia Amended Version of 2012 International Energy Conservation Code July 14, 2014 Climate Zone Since the entire state of Virginia falls in the IECC Climate Zone 4,
Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows
Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows Marc LaFrance Technology Development Manager US Department of Energy Building Technology Program
Introduction & Principles Issued in support of Junction Details, Parts 1 to 5
Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction
Fig. 2 Option 1 Integrated Design using Physical Separation. Fig. 1 Standard Modular Process Skid Design Concept
Modular Integration of Process Equipment Packages for Oil and Gas Facilities Copyright Material PCIC Europe Paper No. PCIC Europe XXXX Allan Bozek EngWorks, Inc. 1620 49 th Avenue, SW Calgary, AB T2T 2T7
Your Personal Home Energy Action Plan
www.centralvalleyenergytuneup.org g Your Personal Home Energy Action Plan 123 Sample Street Fresno, Ca 93710 Home Energy Rater Name Company Evaluation Date Joe Rater Rater Services, Inc. 9/1/2013 This
Ventilation Solutions Kitchens. fantech
Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the
Residential Duct Systems for New and Retrofit Homes
Residential Duct Systems for New and Retrofit Homes Why it is important to properly design and install high quality, efficient ducted air systems? The efficiency of air distribution systems has been found
Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes
Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes Vincent Pedalino FSL Home Improvements Phoenix, AZ 1 HVAC Basics Ways to improve the performance of existing air conditioning
IPM Inspection Form. Entryways Yes No Not Sure N/A
IPM Inspection Form (Pests and Pest Conducive Conditions Checklist) School District School or Site Date Inspected by Entryways Yes No Not Sure N/A Doors closed when not in use Doors shut tight and close
Avantis 75. Windows & Doors. Sapa Building System
Avantis 75 Windows & Doors Sapa Building System Avantis 75 is a thermally broken three-chamber window and door system, which sets the highest standards of thermal insulation and stability. Avantis 75
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
Unbeatable energy efficient glass curtain wall system
Unbeatable energy efficient glass curtain wall system CONTENT Introduction 1 System 2 World Class Engineering 4 Unit Selection 5 Energy Efficiency & Comfort 10 Maximised Installation Efficiency 12 Aesthetics
People work better in Colt conditions Colt Climate Control products and services
People work better in Colt conditions Colt Climate Control products and services People work better in Colt Conditions - Colt climate control systems COLT CONDITIONS We harness the natural elements to
Statement of Work. 1.0 Executive Summary. 2.0 Features & Benefits. Service. Software Education Service. Table of Contents
- 1 - StruxureWare TM for Data Centers Management Software Administrator Training Statement of Work StruxureWare TM for Data Centers Management Software Administrator Training Software Education Service
Mechanical and Natural Ventilation
BBSE3006: Air Conditioning and Refrigeration II http://www.hku.hk/bse/bbse3006/ Mechanical and Natural Ventilation Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong E-mail:
Green and Energy Efficient Homes What you need to know
Green and Energy Efficient Homes What you need to know Introductions Agenda Why green or energy efficiency? What does it mean for a home to be green or energy efficient? Energy Efficient Construction Techniques
2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM
QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM TOGETHERWESAVE.COM IS IT TIME TO REPLACE YOUR HVAC SYSTEM? If your heating and cooling system is 15 to 20 years old and is experiencing problems,
Introduction to DEAP for Professionals DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP)
Introduction to DEAP for Professionals Introduction to DEAP for Professionals 1 DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP) 2 Introduction to DEAP for Professionals Introduction to DEAP for Professionals
Shingle Roofing: What s below the surface is important
What s below the surface is important The roof is leaking, the shingles look old, and the downspouts are dripping. It must be time to replace the roof or is it? Shingle roofs may seem simple, but a roof
First Time Home Buyers Energy Efficiency Workshop Guide
First Time Home Buyers Energy Efficiency Workshop Guide Why is efficiency important when buying a home? Affordability: lower utility bills Environmental responsibility: reduces your carbon footprint and
Norwegian Tax Authority - Oslo Norway
1. INTRODUCTION Norwegian Tax Authority - Oslo Norway PROJECT SUMMARY Year of construction - 1980 No previous energy renovations SPECIAL FEATURES Main topics in the renovation are: High insulated pre fabricated
Affordable Zero Energy
Affordable Zero Energy NEXUS EnergyHomes proves high performance homes don t have to break the bank In historic downtown Frederick, Maryland, the EVHA 2012 Home Builder of the Year, NEXUS EnergyHomes,
The KLINGERexpert 5.2.1
KLINGERexpert 5.2.1 Powerful Sealing Calculation The KLINGERexpert 5.2.1 gasket design program is a versatile piece of software to assist users in the selection of non-metallic gasket materials. KLINGER
Rosslare Case Study Passive House Cost Analysis. Seamus Mullins Quantity Surveyor Michael Bennett Group
Rosslare Case Study Passive House Cost Analysis Seamus Mullins Quantity Surveyor Michael Bennett Group 2 South Elevation North Elevation 3 West Elevation East Elevation 4 Ground Floor Plan 5 First Floor
CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS
CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS Air / Water / DX Cooled Cabinet Solutions Mini Data Centre All in One Solution: Where there is a requirement for standalone computing and communications, or highly
How To Get A Passive House
Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2015 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Product