B Issue A Original. Instruction Manual. nexpt Turbopumping Station
|
|
|
- Alexia Wheeler
- 10 years ago
- Views:
Transcription
1 Instruction Manual B Issue A Original nexpt Turbopumping Station Description nexpt Turbopumping Station Item Number B
2 Declaration of Conformity We, Edwards, Manor Royal, Crawley, West Sussex, RH10 9LW, UK declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s) nexpt Turbopumping Stations T S X X - X X 0 0 X The preceding material numbers cover a matrix where the following features may vary according to:- X denoting a range of turbomolecular pump inlet flanges, vent options and electrical supply which may be configured or used with the following turbomolecular pumps and backing pumps. Turbomolecular pumps: EXT75DX next240d next300d next400d Backing pumps: E2M1.5 RV5 RV12 XDD1 XDS5 XDS10 to which this declaration relates is in conformity with the following standard(s) or other normative document(s) EN ISO : 2003 Safety of Machinery. Basic Concepts, General Principles for + A1: 2009 Design. Technical Principals. EN1012-2:1996, A1: 2009 Compressors and Vacuum Pumps. Safety Requirements, Vacuum Pumps. EN : 2001 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use. General Requirements. EN : 2006 Electrical equipment for measurement, control and laboratory Immunity, Class A Use. EMC requirements. General requirements. Emissions Control and laboratory use Part 1: General requirements. and fulfils all the relevant provisions of 2006/42/EC 2006/95/EC 2004/108/EC 2002/95/EC* Machinery Directive Low Voltage Directive Electromagnetic Compatibility (EMC) Directive Restriction of Certain Hazardous Substances (RoHS) Directive * i.e. The product(s) contain less than - 0.1wt% for hexavalent chromium, lead, mercury, PBB and PBDE; 0.01wt% for cadmium - in homogeneous materials (subject to the exemptions allowed by the Directive). This information relates only to products sold on or after the date of this certificate. Edwards has taken all reasonable steps to confirm this statement, which is based mainly on information from our suppliers. Whilst the RoHS Directive does not legally apply to this vacuum equipment, we recognize that component compliance is relevant to many of our customers. Note: This declaration covers all product serial numbers from the date this Declaration was signed onwards. Barrie Brewster, Technical Manager Scientific Products Burgess Hill Date and Place This product has been manufactured under a quality system registered to ISO9001 P Issue A
3 Contents Section Page 1 Introduction... 1 Contents dcs/8631/ Scope and definitions Description Overview General description of the nexpt turbopumping station major components Electrical protection Accessories Technical data General Electrical data Legislation and standards Operating and storage data Fuse ratings Earth stud Electrical connections Connections Installation Safety Unpack and inspect Locate the nexpt turbopumping station Bench-top mounting Fixing procedure Fill the rotary pump with oil XDS scroll pump silencer Fit accessories (optional) Connect the nexpt turbopumping station to your vacuum system Connect to your exhaust extraction system Connect the electrical supply Additional earth bonding Configure the nexpt turbopumping station Commission the installation Connecting an active gauge Connecting the logic interface Connecting the serial interface Operation Use of the backing pump controls Start-up Shut-down Maintenance Safety Maintenance plan Inspect the hoses, pipelines and connections Trouble-shooting Software updates EXPT TIC controller factory default...21 Edwards Limited All rights reserved. Page i
4 Contents 6 Storage and disposal Storage Disposal Spares and accessories Introduction Spares Accessories BX bakeout band...25 For return of equipment, complete the HS Forms at the end of this manual. Illustrations Figure Page 1 Components of the nexpt turbopumping station (typical system shown) Equipment dimensions (mm) (XDS and next shown) Position the lifting slings/lifting hooks Bench-top mounting M8 clearance holes Turbomolecular pump start delay with XDD1 diaphragm pump EXPT TIC...21 Tables Table Page 1 Electrical data Operating and storage data Fuse ratings Earth stud Electrical connections Connections Checklist of components... 9 Page ii Edwards Limited All rights reserved.
5 Supplementary publications Publication title XDD1 115/230 Diaphragm Pump Turbo Instrument Controller (TIC) EXT EXT75DX and EXT255DX Turbomolecular Pump XDS Scroll Pump RV Rotary Vane Pumps next Turbomolecular Pumps CD ROM Instruction Manual Publication number A D B A A B B Contents Associated publications Publication title EXT Pump Accessories Publication number B Edwards Limited All rights reserved. Page iii
6 This page has been intentionally left blank. Page iv Edwards Limited All rights reserved.
7 1 Introduction 1.1 Scope and definitions This manual provides installation, operation and maintenance instructions for the Edwards nexpt Turbopumping Station. You must use the nexpt Turbopumping Station as specified in this manual. Read this manual before you install and operate the nexpt Turbopumping Station. Important safety information is highlighted as WARNING and CAUTION instructions; you must obey these instructions. The use of WARNINGS and CAUTIONS is defined below. Introduction WARNING Warnings are given where failure to observe the instruction could result in injury or death to people. CAUTION Cautions are given where failure to observe the instruction could result in damage to the equipment, associated equipment and process. A full list of Supplementary Publications is provided at the end of the Contents list of this manual. A number of these Supplementary Publications will be supplied with your nexpt Turbopumping Station. The Supplementary Publications supplied will be the instruction manuals for the components in your nexpt Turbopumping Station. The Supplementary Publications you receive also contain WARNING and CAUTION instructions. When you install and operate the nexpt Turbopumping Station, you must refer to these Supplementary Publications and obey all of the WARNING and CAUTION instructions which they contain. The units used throughout this manual conform to the SI international system of units of measurement. The following IEC warning labels appear on the product and in the manual. Warning refer to accompanying documentation. Warning risk of electric shock. Warning hot surfaces. Edwards Limited All rights reserved. Page 1
8 Introduction 1.2 Description Overview Your nexpt Turbopumping Station is a fully automatic pumping system which is suitable for a wide range of applications. The system is capable of utilising a range of standard Edwards backing pumps and turbomolecular pumps from a single compact unit. The nexpt Turbopumping Station is available in two sizes, the size of the equipment base will depend on which backing pump is fitted. The open system configuration allows easy maintenance of the main pumping components. The TIC controller has been configured to operate both the backing pump and the turbomolecular pump plus any optional accessories which have been fitted. Up to three active gauges can be connected using the convenient gauge interface incorporated into the system housing. The controller uses a large clear graphic display and easy-to-use control interface via a touch sensitive keypad. All systems incorporate a RS232/485 interface for control and data monitoring on a remote PC and a logic interface for interface with associated system hardware General description of the nexpt turbopumping station major components For the general description of the various products used on the nexpt Turbopumping Station, click on the appropriate instruction manual reference against each product type. Diaphragm pump XDD1 (A ) Rotary vane pumps E2M0.7 / E2M1.5 (A Section 1.2) RV3 / RV5 / RV8 / RV12 (A Section 1.2) Turbomolecular pumps EXT75DX / EXT255DX (B Section 1.2) next240 / next300 / next400 (B Section 1.2) Scroll pumps XDS5 / XDS10 (A Section 1.2) TIC controller Turbo instrument controller (D Section 1.2) Electrical protection The nexpt Turbopumping Station has a double-pole thermal circuit breaker which provides short circuit protection. The backing pump and TIC Controller both have overload protection Accessories A wide range of standard accessories is available for the major components of the nexpt Turbopumping Station; refer to Section 7. Page 2 Edwards Limited All rights reserved.
9 Figure 1 - Components of the nexpt turbopumping station (typical system shown) Introduction 1. Mains ON/OFF 2. Logic interface (adaptor fitted) 3. Serial communications port 4. Mains input 5. Bakeout band fuse (not fitted) * 6. Backing pump fuse 7. TAV vent valve (optional) 8. Instruction manual holder 9. Backing pump 10. Vacuum gauge inputs 11. Backing pump mains supply 12. Earth stud 13. Bakeout band mains supply 14. Backing pump isolation valve (Fitted to XDS backing pumps only) 15. Turbomolecular pump 16. TIC controller 17. Locking castors (front and rear) * Refer to Table 3 of manual B for the correct fuse rating. Baking the turbo pump on the Pumping Station is prohibited. Refer to Section 3.7 for further information. Edwards Limited All rights reserved. Page 3
10 This page has been intentionally left blank. Page 4 Edwards Limited All rights reserved.
11 2 Technical data Note: The operating, storage conditions and performance of the nexpt Turbopumping Station depends on the major components fitted to the nexpt Turbopumping Station; refer to the technical data in the appropriate supplementary publications. 2.1 General Dimensions Refer to Figure 2 Mass Small platform 24.9 to 35.0 kg (E2M/XDD1) Mass Large platform 41.2 to 52.5 kg (RV/XDS) Electrical data Refer to Table 1 Degree of protection (to IEC34-5: 1981) IP20 Initial force required to push the nexpt Turbopumping Station * 3.5 kgf max. (for systems with castors) * Measured under ideal conditions and will increase on uneven floor surfaces, slopes etc. Technical data 2.2 Electrical data Table 1 lists the electrical requirements for the different nexpt Turbopumping Stations. Backing pump TIC controller Table 1 - Electrical data Supply voltage 50/60 Hz Current (A) Full load Start * Maximum power kw XDD1 100 W E2M1.5 RV5 200 W 100 W 200 W 100 W 200 W Edwards Limited All rights reserved. Page 5
12 Technical data * Backing pump RV12 XDS5/10 TIC controller 100 W 200 W 100 W 200 W Table 1 - Electrical data (continued) Supply voltage 50/60 Hz Current (A) Full load Start * Maximum power kw If the nexpt Turbopumping Station uses a rotary vane pump, the system may draw up to the start current value shown in Table 1. You must use a slow blow fuse to prevent unnecessary fuse failures, the start current could typically last for several seconds and generally occurs when the rotary vane pump oil is cold Legislation and standards The legislation and standards with which the nexpt Turbopumping Station complies are listed in full on the Declaration of Conformity shown on the front inside cover of this manual. 2.4 Operating and storage data Table 2 - Operating and storage data General items Reference data Ambient operating temperature range 0 C to 35 C Ambient storage temperature range -30 C to 70 C Maximum ambient operating humidity Max 90% RH non cond at 40 C Maximum operating altitude 2000 m max. Equipment type Fixed equipment, for indoor use only Pollution degree 2 Page 6 Edwards Limited All rights reserved.
13 2.5 Fuse ratings Table 3 - Fuse ratings General items Reference data BX bakeout band fuse (Heater) 90 to 132 V a.c. electrical supply 1 A, type F 20 mm 180 to 264 V a.c. electrical supply 0.5 A, type F 20 mm Backing pump Refer to backing pump documentation 10 A, type T 20 mm (maximum) Technical data 2.6 Earth stud Table 4 - Earth stud General items Earth stud Reference data M5 2.7 Electrical connections Table 5 - Electrical connections General items Reference data Electrical supply (refer to Figure 1, item 4) Inlet plug type CEE/IEC 320 (16 A) Backing pump (refer to Figure 1, item 10) Outlet socket type CEE/IEC 320 Max power 600 W Bakeout band (refer to Figure 1, item 12) Outlet socket type CEE/IEC 320 Max power 150 W 2.8 Connections Note: The connectors listed in Table 6 offer the same functionality as the connectors on the TIC Controller. Refer to the TIC instruction manual for full details for these connectors. Table 6 - Connections General items Active gauge connectors Connector type Power supply Logic interface Connector type Power supply Reference data FCC/RJ45, 8-way 24 V d.c. 25-way sub-miniature D type socket 24 V d.c. Edwards Limited All rights reserved. Page 7
14 Technical data General items Serial communications Connector type Table 6 - Connections (continued) Reference data 9-way sub-miniature D type socket Figure 2 - Equipment dimensions (mm) (XDS and next shown) Turbo Pump Dimensions (mm) Position A Position B * Position C EXT75DX ISO / EXT75DX NW / EXT75DX CF / next240d ISO / next240d CF / next300d ISO / next300d CF / next400d ISO / next400d CF / * 380 mm refers to small platforms with XDD1 backing pumps. 500 mm refers to large platforms with XDS/RV backing pumps. Page 8 Edwards Limited All rights reserved.
15 3 Installation 3.1 Safety WARNING Obey the safety instructions given below and take note of appropriate precautions. If you do not, you can cause injury to people and damage to equipment. Installation When you refer to a manual supplied as a Supplementary Publication, you must obey all of the WARNING and CAUTION instructions in the manual. A suitably trained and supervised technician must install the nexpt Turbopumping Station. Check that all the required parts are available and of the correct type before you start work. Ensure that the installation technician is familiar with the safety procedures which relate to the products pumped. Wear the appropriate safety-clothing when you come into contact with contaminated components. Isolate the other components in your system from the electrical supply so that they cannot be operated accidentally. Do not reuse O-rings and Co-Seals if they are damaged. Dispose of components, grease and oil safely (refer to Section 6). Take care to protect sealing-faces from damage. Leak-test the system after installation and seal any leaks found. 3.2 Unpack and inspect Remove the outer cover and all packing materials, remove the protective covers from the inlet and outlet ports, inspect the system for any damage. If the nexpt Turbopumping Station is damaged, notify your supplier and the carrier in writing within three days; state your order number and invoice number. Retain all packing materials for inspection. Do not use the nexpt Turbopumping Station if it is damaged. Check that your package contains the items listed in Table 7. If any item is missing, notify your supplier within three days. If the nexpt Turbopumping Station is not to be used immediately, replace the protective covers. Store the nexpt Turbopumping Station in suitable conditions as described in Section 6.1. Table 7 - Checklist of components Qty Description Check ( ) 1 nexpt Turbopumping Station 1 Instruction Manual Package 1 Logic Interface Interlock D-Connector 1 TMP Flange Inlet Seal 1 Rotary Pump Oil (RV/E2M pumps only) 4 Mounting-pillars (used for bench-top fixing) Edwards Limited All rights reserved. Page 9
16 Installation 3.3 Locate the nexpt turbopumping station WARNING Heavy objects can cause muscle strain or back injury. It is advisable to use suitable lifting equipment when moving the nexpt Turbopumping Station. WARNING For your safety, all four castors must be locked when the equipment is in operation. If you fail to follow this warning and the turbo pump seizes, the sudden movement of the nexpt Turbopumping Station may cause further damage to the equipment and cause injury to people. WARNING If you operate your nexpt Turbopumping Station on a bench-top, you must follow the installation instructions in Section 3.4. If you fail to follow these guidelines and the turbo pump seizes, the sudden movement of the nexpt Turbopumping Station may cause further damage to the equipment and cause injury to people. CAUTION When lifting the nexpt Turbopumping Station, do not attempt to support the mass of the system from the backing pump. CAUTION When lifting the nexpt Turbopumping Station, always use slings with sufficient length to prevent damage of the system components. Before attempting to lift the nexpt Turbopumping Station, move the system (on its pallet) close to the operating position. Ensure that you provide a firm level base before removing the system from its pallet. It is advisable to always use mechanical lifting equipment when moving the larger platform nextp Turbopumping System. Use slings around the base of the system from front to back, make sure each sling is routed between the castors or feet and the base guides to prevent slippage. Alternatively use straps with lifting hooks. Refer to Figure 3 which shows where to locate the slings or lifting hooks. CAUTION When locating the nexpt Turbopumping Station, care should be taken not to restrict the ventilation grid located under the base of the system. Failing to observe this may result in over heating of the controller and the turbomolecular pump. Page 10 Edwards Limited All rights reserved.
17 Figure 3 - Position the lifting slings/lifting hooks Installation 3.4 Bench-top mounting The base of the nexpt Turbopumping Station can be securely fixed to your bench-top using the mounting-pillars supplied, refer to Figure 4. Figure 4 - Bench-top mounting WARNING Ensure the bench-top you are operating the nexpt Turbopumping Station on is firmly fixed to a support or wall and can support the weight of the equipment. Your bench-top must be able to withstand a destructive torque of up to 4.25 knm in the unlikely event that the turbo pump seizes. Edwards Limited All rights reserved. Page 11
18 Installation Fixing procedure 1. Drill four M8 clearance holes in your bench-top, refer to Figure 5. Figure 5 - M8 clearance holes 2. Raise the nexpt Turbopumping Station and place on blocks if required so that all four castors are accessible. 3. Remove all four castors by unscrewing the M8 nut holding the castor to the base, retain the nuts and washers for the next stage. We recommend that you should keep the castors in a safe place in case they are required again in the future. 4. Fit the mounting-pillars into the now vacant holes using the M8 nuts and washers previously used to secure the castors. Ensure that all four nuts are securely fastened. 5. Locate the nexpt Turbopumping Station by aligning the mounting-pillars with the holes previously made in your bench-top, secure the nexpt Turbopumping Station using M8 bolts (not supplied). It is advisable to use washers either side of the bench-top surface. Ensure that all four bolts are securely fastened. 3.5 Fill the rotary pump with oil If the nexpt Turbopumping Station uses a EM or RV series rotary or rotary vane pump you must fill it with the correct quantity of oil (supplied with the equipment) before you operate the equipment, as described in the pump Instruction Manual. Page 12 Edwards Limited All rights reserved.
19 3.6 XDS scroll pump silencer The silencer is used to reduce exhaust noise during pump down and gas ballast operations. This part can be ordered as an accessory, refer to Section 7.3. To fit the silencer, follow the instructions in manual A Fit accessories (optional) If you wish to fit accessories to the nexpt Turbopumping Station, fit them now, before you start to install the nexpt Turbopumping Station into your vacuum system. Install accessories as described in the instruction manuals supplied with the accessories. Refer to Section 7 for further information on the accessories available and for specific fitting instructions to fit the accessories to the nexpt Turbopumping Station. Installation Note: The use of water coolers and BX bake-out bands on the nexpt Turbopumping Station is not permitted. If you wish to fit these accessories, it is advisable to install the turbomolecular pump away from the nexpt Turbopumping Station. For further details regarding turbomolecular pump remote mounting please contact Edwards UK. 3.8 Connect the nexpt turbopumping station to your vacuum system WARNING Connect the turbo pump inlet to your vacuum system before applying power to the nexpt Turbopumping Station. This will ensure that the pump cannot operate accidentally causing injury. WARNING If you install your vacuum system directly onto the nexpt turbopumping station, the centre of gravity of the mass must be above and within 300 mm of the centre line. The turbo pump can be securely fixed to the vacuum system via the inlet-flange. Make sure that the pump-inlet and all components fitted to the pump-inlet are clean and dust-free. If the pump-inlet is not kept clean, the pump-down time may be increased. The inlet connections for the next pump are CF flange and the ISO flange: If the pump has a CF flange, use the copper compression gasket supplied with the pump and use a full complement of bolts to connect the inlet-flange of the pump to the vacuum system. If the pump has an ISO flange, use the Edwards combined inlet screen and trapped O-ring supplied with the pump and use a minimum of four claw clamps (each torque to 10 Nm) to connect the inlet-flange of the pump to the vacuum system. Alternatively, use a rotatable collar and the combined inlet screen and trapped O-ring supplied with the pump to connect the inlet-flange of the pump to the vacuum system; use a full complement of bolts with the rotatable collar. All inlet flange bolts must be re-tightened once the system is under vacuum. Ensure that no torques or other forces are transmitted to the pump from the vacuum system or the associated pipelines. 3.9 Connect to your exhaust extraction system Note: For further information, refer to the instruction manual which corresponds to the backing pump fitted to your nexpt Turbopumping Station. Edwards Limited All rights reserved. Page 13
20 Installation 3.10 Connect the electrical supply WARNING Ensure that the electrical installation of the EXPT Turbopumping Station conforms with your local and national safety requirements. It must be connected to a suitably fused and protected electrical supply and a suitable earth point. WARNING Ensure the mains cord is routed so as not to cause a trip hazard. Check that your electrical supply is suitable for this equipment. Refer to Table 1 for the electrical requirements for this equipment. The nexpt Turbopumping Station is supplied with an electrical cable which includes a moulded IEC connector fitted at one end, the other end of the cable will be fitted with a moulded plug suitable for connection to the local electrical supply Additional earth bonding The electrical supply cable normally provides protective earthing for electrical safety. If this is not the case, or if additional earth bonding is required, the earth stud located on the base at the rear of the nexpt Turbopumping Station should be connected to your vacuum system Configure the nexpt turbopumping station As supplied, the TIC Controller has been reconfigured for the TIC Pumping Station to suit most vacuum applications and will: When the TIC System ON is selected: Switch on both the backing pump and the turbomolecular pump *. Close the TAV vent valve. Open the backing valve. When the TIC System OFF is selected: Switch off both the backing pump and the turbomolecular pump. Close the backing valve. Open the TAV vent valve (controlled venting) from % rotational speed, and then open fully from 50% of full rotational speed. * If your nexpt Turbopumping Station uses an XDD1 diaphragm pump, the turbomolecular pump drive will be delayed for two minutes while the backing pump reduces the pressure to a suitable level, this is typical for a five litre volume and will prevent the turbomolecular pump from running under high pressure for a prolonged period. This delay is adjustable (refer to the TIC instruction manual) and is recommended for system volumes >2 litres, refer to Figure 6 to estimate the turbomolecular start delay if you know your system volume. Page 14 Edwards Limited All rights reserved.
21 Notes: 1 The TAV valve is an optional extra 2 The TIC Controller factory settings have been changed to provide a standard operation for the nexpt Turbopumping Station, if you replace the TIC Controller you should reconfigure the set up options to suit your application, refer to the TIC instruction manual for further details. Figure 6 - Turbomolecular pump start delay with XDD1 diaphragm pump Installation 3.13 Commission the installation WARNING Do not operate the system with the exhaust pipeline blocked. For example, if your nexpt Turbopumping Station uses a rotary vane pump, oil mist may be discharged from the oil mist filter and cause injury to people. After you have installed the nexpt Turbopumping Station, use the following procedure to test the system. 1. Make sure that all the electrical connections are secure. 2. Switch on the electrical supply and your exhaust-extraction system (if available). 3. Turn ON the nexpt Turbopumping Station using the ON/OFF switch positioned on the rear panel. To start-up the equipment, refer to the TIC instruction manual. Check that the equipment operates as described in Section Inspect the vacuum, exhaust and pipeline connections and check that there are no leaks. Seal if any leaks are found. 5. Wait until the turbomolecular pump has reached full speed, then select OFF on the front panel of the TIC Controller again; check that both pumps stop. Edwards Limited All rights reserved. Page 15
22 Installation 3.14 Connecting an active gauge CAUTION Do not connect Barocel capacitance manometers to the TIC Pumping Station gauge connectors. Doing so will result in damage to the gauge and will invalidate the warranty. Up to three compatible active gauges can be fitted to the gauge connectors on the rear inside of the nexpt Turbopumping Station housing, refer to Figure 1. Connect the gauges using Edwards active gauge cables to each of the three sockets, the number indicated above each socket corresponds to the same gauge number shown on the TIC Controller display. This option is only available if the nexpt Turbopumping Station uses a TIC turbo and instrument controller. Note: Only one AIGX gauge can be connected to the TIC Pumping Station gauge connectors at a time Connecting the logic interface CAUTION Do not earth the logic interface 0 V lines (pins 7, 10, 12, and 13). If you do, you will provide an earth return path for any electrical fault in the pump-motor and this could damage your Controller or your control equipment. CAUTION Do not connect voltages greater than 24 V to the logic interface. The logic interface provides a number of signals that can be used for monitoring the status of your vacuum system, and for controlling certain aspects of its operation. These signals can be broadly divided into three groups, control inputs, control outputs and status outputs. The nexpt Turbopumping Station is supplied with an interlock D-connector connected into the logic interface at the rear of the equipment. If you do not intend to connect the logic interface to your system you must use the interlock D-connector, failing to do so will disable a number of control outputs which operate the nexpt system. Note: The user logic interface on the rear panel offers the same functionality as the logic interface on the TIC Controller. Refer to the TIC instruction manual for further details of this connector Connecting the serial interface The TIC has two serial communications protocols built in, RS232 and RS485. RS232 is the simplest interface and can be used to allow a host PC to control the TIC. RS485 allows a host PC to control a small network of TICs. Note: The user serial interface on the rear panel offers the same functionality as the serial interface on the TIC Controller. Refer to the TIC instruction manual for further details of this connector. Page 16 Edwards Limited All rights reserved.
23 4 Operation 4.1 Use of the backing pump controls If the backing pump has a mode selector and or gas-ballast control, refer to the appropriate backing pump instruction manual to optimise the performance of the pump for your application. Operation 4.2 Start-up Use the following procedure to start the nexpt Turbopumping Station. If you wish to reconfigure the operation of the nexpt Turbopumping Station to suit an application, refer to the TIC instruction manual. 1. Switch on the electrical supply to the nexpt Turbopumping Station and your exhaust-extraction system (if available). 2. Turn ON the nexpt Turbopumping Station using the ON/OFF switch positioned on the rear panel. 3. To operate the equipment components, refer to the TIC instruction manual for full operation. 4.3 Shut-down Use the following procedure to shut down the nexpt Turbopumping Station. 1. Refer to the TIC Controller instruction manual to stop the turbomolecular pump (TMP) and backing pump operation. 2. Switch off the ON/OFF rocker switch located on the equipment rear panel. 3. Remove the electrical mains supply from the equipment. Edwards Limited All rights reserved. Page 17
24 This page has been intentionally left blank. Page 18 Edwards Limited All rights reserved.
25 5 Maintenance 5.1 Safety WARNING Obey the safety instructions given below and take note of appropriate precautions. If you do not, you can cause injury to people and damage to equipment. Maintenance When you refer to a manual supplied as a Supplementary Publication, you must obey all of the WARNING and CAUTION instructions in the manual. A suitably trained and supervised technician must maintain the nexpt Turbopumping Station. Allow the pumps to cool to a safe temperature before you start maintenance work. Check that all the required parts are available and of the correct type before you start work. Ensure that the maintenance technician is familiar with the safety procedures which relate to the products pumped. Wear the appropriate safety-clothing when you come into contact with contaminated components. Dismantle and clean contaminated components in a fume-cupboard. Isolate the nexpt Turbopumping Station and other components in the system from the electrical supply so that they cannot be operated accidentally. Do not reuse O-rings and Co-Seals if they are damaged. Dispose of components, grease and oil safely (refer to Section 6). Protect sealing-faces from damage. Do not touch or inhale the thermal breakdown products of fluoroelastomer seals. These breakdown products are very dangerous and may be present if the nexpt Turbopumping Station has been heated to 260 C and above. Leak-test the system after maintenance and seal any leaks found if you have disconnected any vacuum or exhaust pipeline connections. 5.2 Maintenance plan The following documents list the minimum maintenance operations necessary to maintain the nexpt Turbopumping Station in normal use. More frequent maintenance may be necessary if the nexpt Turbopumping Station has been used to pump corrosive or abrasive gases and vapours. If necessary, adjust the maintenance plan according to your experience. EXT pumps Turbomolecular pumps Backing pumps Diaphragm pump Rotary vane pumps Scroll pumps EXT75DX (B ) next240 / next300 / next400 (B ) XDD1 (A ) E2M0.7 / E2M1.5 (A ) RV5 / RV12 (A ) XDS5 / XDS10 (A ) Edwards Limited All rights reserved. Page 19
26 Maintenance 5.3 Inspect the hoses, pipelines and connections 1. If the turbomolecular pump on your nexpt Turbopumping Station is water-cooled: Inspect all of the cooling-water connections and check that they are secure. Tighten any loose connections. Inspect all cooling-water hoses, pipelines and connections and check that they are not corroded or damaged and that they do not leak. Replace or repair any corroded or damaged component and seal any leaks found. 2. Inspect all of the electrical connections and check that they are secure. Tighten any loose connections. 3. Inspect all of the electrical cables and check that they are not damaged and have not overheated. Replace or repair any damaged or overheated cable. 4. Inspect all of the vacuum and exhaust connections and check that they are secure. Tighten any loose connections. 5. Inspect all of the vacuum and exhaust pipelines and check that they are not corroded or damaged and that they do not leak. Replace or repair any corroded or damaged component and seal any leaks found. 5.4 Trouble-shooting WARNING If you remove the turbo pump for maintenance purpose, you must reuse all screws which were used to secure both the turbo pump and the turbo mounting plate onto the nexpt Turbopumping Station. If you have lost or cannot reuse any of these screws, a minimum screw strength of 12.9 M8 x for the turbo pump, and 8.8 M8 x 30 for the turbo mounting plate must be used. If you fail to follow this warning and the turbo pump seizes, the stored energy in the turbo pump may cause some or all of the screws to fail, this may result in the turbo pump being ejected from the nexpt Turbopumping Station main housing. For trouble-shooting instructions on the nexpt Turbopumping Station, refer to the following documents: EXT pumps Turbomolecular pumps Backing pumps Diaphragm pump Rotary vane pumps Scroll pumps EXT75DX (B ) next240 / next300/ next400 (B ) XDD1 (A ) E2M0.7 / E2M1.5 (A ) RV5 / RV12 (A ) XDS5 / XDS10 (A ) TIC controller TIC controller Turbo instrument controller (D ) 5.5 Software updates The software within the Controller and the TIC PC monitor program will be updated as part of Edwards ongoing development program. The updates and associated instruction manual can be found by visiting Page 20 Edwards Limited All rights reserved.
27 5.6 EXPT TIC controller factory default The EXPT TIC controller has been setup to provide optimum control for your Pumping Cart, however, the default settings can be changed to suit your system control. Note: When performing a software update, the TIC will resume back to its original factory default setting, this is different to the nexpt Turbopumping Station settings. You may need to upload the Pumping Station settings or your personal settings using the TIC PC Monitoring software before you perform a software update. Once the update is complete, you can then download the previous settings back into your TIC controller. Figure 7 below shows the view screen shortcuts and menu structure for the Pumping Station TIC setup. For details of navigating and changing system parameters, refer to the TIC instruction manual. Maintenance Figure 7 - EXPT TIC 1. A 2 min start delay is recommended if your Pumping Station has been configured to use a XDD1 diaphragm pump. 2. This option should be used if your system uses a DX pump. Edwards Limited All rights reserved. Page 21
28 This page has been intentionally left blank. Page 22 Edwards Limited All rights reserved.
29 6 Storage and disposal Note: We recommend that you avoid long-term storage of the nexpt Turbopumping Station. If you will store the nexpt Turbopumping Station for several months, refer to the storage instructions in the relevant instruction manual. 6.1 Storage Use the following procedure to store the nexpt Turbopumping Station: 1. Shut down the nexpt Turbopumping Station as described in Section Isolate the nexpt Turbopumping Station from the electrical supply and disconnect it from the vacuum system. 3. Drain the oil from the backing pump (rotary vane pumps only) as described in the instruction manual for the pump. Refer to the following documents: Storage and disposal Rotary vane pumps E2M0.7 / E2M1.5 (A ) RV5 / RV12 (A ) 4. Place protective covers over the inlet and outlet-flanges. 5. For the fastest pump-down after the nexpt Turbopumping Station is re-installed, seal the turbomolecular pump inside a plastic bag together with a suitable desiccant. 6. Store the nexpt Turbopumping Station in cool, dry conditions until required for use. 6.2 Disposal Dispose of the nexpt Turbopumping Station and any components safely in accordance with all local and national safety and environmental requirements. Particular care must be taken with components which have been contaminated with dangerous process substances. Edwards Limited All rights reserved. Page 23
30 This page has been intentionally left blank. Page 24 Edwards Limited All rights reserved.
31 7 Spares and accessories 7.1 Introduction Edwards products, spares and accessories are available from Edwards companies in Belgium, Brazil, Canada, France, Germany, Hong Kong, Italy, Japan, Korea, Switzerland, United Kingdom, U.S.A. and a worldwide network of distributors. The majority of these centres employ Service Engineers who have undergone comprehensive Edwards training courses. Order spare parts and accessories from your nearest Edwards company or distributor. When you order, state for each part required: Model and Item Number of your equipment Serial number (if any) Item Number and description of the part. Fit accessories as described in the Supplementary Publications and in the instruction manual supplied with the accessory. Spares and accessories 7.2 Spares The spares available for use with the nexpt Turbopumping Station (including replacement component parts) are listed in the instruction manuals supplied as Supplementary Publications. 7.3 Accessories Refer to the Edwards product catalogue for all turbo and backing pump accessories used on the nexpt Turbopumping Station BX bakeout band The BX bakeout band should only be used on turbomolecular pumps intended to be used remotely away from the nexpt Turbopumping Station. For further details please contact Edwards UK. Edwards Limited All rights reserved. Page 25
32 This page has been intentionally left blank. Page 26 Edwards Limited All rights reserved.
B723-00-000. Issue B Original. Instruction Manual. EXPT Pumping Station
Instruction Manual B723-00-880 Issue B Original EXPT Pumping Station Description EXPT Pumping Station Item Number B723-00-000 Contents Section Page 1 Introduction... 1 Contents ITR 21466 1.1 Scope and
D397-12-880 Issue D Original. Instruction Manual. Turbo Controller. TIC Turbo Controller 200W
D397-12-880 Issue D Original Instruction Manual Turbo Controller Description TIC Turbo Controller 100W TIC Turbo Controller 200W Item Number D397-11-000 D397-12-000 CONTENTS Section Title Page 1 INTRODUCTION
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
Agilent 87421A/87422A Power Supply
Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
Model 1756 Test Lead Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Spetec Laminar Flow Systems. Operating Instructions
Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for
MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com
MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
This instruction is valid for all ACD pump models shown on page 2
Screw pumps ACD Maintenance and Service Instruction This instruction is valid for all ACD pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service intervals
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR INTRODUCTION The Cirro MK 3 is a fully professional mist generator for producing sufficient airborne reflection particles to enable effect lighting to
Bubble King. User Manual
Bubble King User Manual TABLE OF CONTENTS 1. Before You Begin... 3 What Is Included... 3 Unpacking Instructions... 3 Claims... 3 Text Conventions... 3 Icons... 3 Document Information... 3 Product at a
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
REMOVAL AND INSTALLATION
303-01C-1 REMOVAL AND INSTALLATION Engine Body On Special Tool(s) Adapter For 303-D043 303-D043-02 or equivalent Special Tool(s) 303-01C-1 Turbocharger Lifting Bracket 303-1266 Wrench, Fan Clutch Nut 303-214
Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V
Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
Operating Instructions Drill rig DRU160
Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
SMD Rework Station TABLE OF CONTENTS
SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating
MagIC 6100. Installation Manual. Point of Sales Terminals TD06014B
MagIC 6100 Installation Manual Point of Sales Terminals TD06014B Contents Description 3 Introduction 3 Presentation of the MagIC 6100 terminal 3 Technical Data 4 Installation 5 Unpacking 5 Safety recommendations
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
HG600/HG800. Hydro-Power Unit. Installation and Operation Guide
HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Getting Started Getting Started with the Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 You only need a few minutes to get started
Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR
CAUTION! Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR NOTE: read the manual prior to commencement of use. For safety reasons, the pump can only be operated by
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.
Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
MOLECULAR DRAG PUMPS MDP SERIES
MOLECULAR DRAG PUMPS MDP SERIES MOLECULAR DRAG PUMPS MDP SERIES If you need: to replace a rotary vane pump with a dry pump for an application at 10-3 a turbopump that can operate up to 10 a pump that can
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
How To Set Up An Inverter
MAKING MODERN LIVING POSSIBLE SOLAR INVERTERS Installation Guide GSM Option Kit FLX series www.danfoss.com/solar Safety Safety Safety Message Types WARNING Safety information important for human safety.
Multi Tube Rotator. Model No. 4632Q 4632-1CE 4632-1CECN 057-213-00 11/05/11
Multi Tube Rotator Model No. 4632Q 4632-1CE 4632-1CECN 057-213-00 11/05/11 Table of Contents Safety Information...3 Alert Signals...3 Description...4 Specifications...5 Power Requirements...5 Shaker Motion...5
FT-100 Fire Training Fog Machine User Manual English
FT-100 Fire Training Fog Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual - English Safety Information Please read the following safety information carefully before operating
R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide
R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide (=7ÔWÌ) 1307.7039.62 06 Test & Measurement Quick Start Guide This Quick Start Guide describes the following converter
Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF
Operating Manual Los Angeles Abrasion Machine HM-70A & HM-70AF Rev: 07/19/2012 PHONE: 800-444-1508 P.O. Box 200, Lewis Center, Ohio 43035-0200 FAX: 800-255-5314 740-548-7298 E-mail: [email protected]
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
42U/45U 28" Wide Rack Installation & Service Guide
42U/45U 28" Wide Rack Installation & Service Guide 96-00171-005 Rev B Important Information Information in this document is subject to change without notice and does not represent a commitment on the part
Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415
Operation Instructions KleeBlower Compressor/Vacuum pumps Models: KB129 KB8415 Brd. Klee A/S All rights reserved Edition 01/2012 Head office: Branch office: Brd. Klee A/S Klee Engineering Ltd Gadagervej
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
804 Ti Stand. Manual 8.804.8001EN
804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
Hot Water Urns. all models. Helpline. v3.0
Hot Water Urns all models Helpline 01384 573999 instructions.indd 1 v3.0 02/06/2014 14:50 IMPORTANT INFORMATION - RETAIN FOR FUTURE USE When using any electrical appliance, basic safety precautions should
Uninterruptible Power Supply. 500 kva - 750 kva
9 315 Uninterruptible Power Supply 500 kva - 750 kva T1 and T3 Installation Addendum 164201244-001 Rev. A ------------------------------------------------------------------------ ------------------------------------------------------------------------
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
233871 George master UK A06.indd 1 07/02/2012 10:25:11
233871 George master UK A06.indd 1 07/02/2012 10:25:11 Contents / Kits - A26A / A40A / A43 2 233871 George master UK A06.indd 2 07/02/2012 10:25:14 Wet - Assembling the machine for extraction use 3 233871
US Installation Manual Smappee Monitor
US Installation Manual Smappee Monitor Version 1.3 English, US, version 1.3, revision 23, as of October 23, 2014, 2013 Smappee NV. All rights reserved. Specifications are subject to change without notice.
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
Online UPS. PowerWalker VFI 1000R/1U
Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.
- 2 - IMPORTANT SAFETY REMINDERS
USER MANUAL IMPORTANT SAFETY REMINDERS This appliance should only be used for domestic cleaning, as described in this user guide. Please ensure that this guide is fully understood before operating the
USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water
INSTALLATION GUIDE 1
INSTALLATION GUIDE 1 Setting information MAC-558IF-E address(mac) MAC-558IF-E serial number(id) MAC-558IF-E code(pin) Indoor unit model name Indoor unit serial number Outdoor unit model name Outdoor unit
MIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Vax model number: Version 1.0
VRS5W Powermax User Guide V1.0.qxd:V1.0 23/7/10 15:35 Page 1 Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308 Carpet Washer Vax model number: VRS5W instruction manual Version 1.0 Please read carefully
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
Turbocharger system components, servicing
21-1 Turbocharger system components, servicing Engine codes: AAZ, 1Z, AHU Observe rules of cleanliness Page 21-10 Turbocharger hoses and lines, connecting Page 21-11 WARNING! Do not re-use any fasteners
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
Senses SV series industrial monitor user manual
Industrial Monitors Senses SV series Senses SV19 / SV17 User manual (Issue A) Part No: 85090084 Page 1 of 25 Copyright Copyright 2008 Amplicon Liveline Ltd. All rights reserved. This publication, including
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011
OWNER S MANUAL th DRAINVAC ATOMIK PRINTED APRIL 4-2011 INTRODUCTION We take this opportunity to express our gratitude and extend our congratulations for your decision to purchase a Drainvac product. A
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet