Energy lntelligence PDU for Data Centers
|
|
|
- Ariel Poole
- 10 years ago
- Views:
Transcription
1 Energy lntelligence PDU for Data Centers 2013
2 Our Vision Simply Better Connections has always been at the heart of the ATEN brand. It means providing innovative solutions for you to make better connections, efficiently and seamlessly, to the information and people that you value. As a result, ATEN connects you to the world, anytime and anywhere, by providing technologies that enable you to share and to care. ATEN makes professional and personal life easier, simpler, and better connected. About ATEN ATEN, established in 1979, is specialized in connectivity and management solutions in accessing and sharing technologies. ATEN consolidates all of its products and services under one brand ATEN, in order to provide an efficient and consistent service standard. The ATEN brand consists of innovative solutions applied to connectivity, professional audio/video, and green energy, for consumers, small/home offices (SOHO), small to medium sized businesses (SMB), and enterprise customers. ATEN s Energy Intelligence PDUs for Data Centers At ATEN we are committed to offering real solutions for data centers, to this end, ATEN s Green Energy solutions offer the latest in energy intelligence. Our solutions for data centers begin with a wide range of eco PDUs, developed to support ISO50001, that take intelligence to the next level by providing real-time energy management, control, and energy-saving efficiency by allowing you to easily upgrade current IT resources quickly and cost effectively. As PDU experts we have developed a variety of standardized and modularized rack PDUs in both 1U and 0U types to suit most data centers. As PDU experts we understand that some data centers have requirements that can t be met effectively with off the shelf models, therefore we also offer customers a BTC Build to Configuration service to construct PDUs according to their individual requirements, effectively providing the ideal power solution. ATEN s dedicated PDU team offer professional solutions in developing energy efficiency. Only with accurate measurements and accurate data can data centers develop effective strategies and employ effective technologies for energy reduction. ATEN delivers and we care about our customers. We are committed to the best customer support in the industry. PDU Comparison Features 1U PE6 1U PE8 PE1/PE2 PE5 PE6 PE7 PE8 PE9 PE6108 PE6208 PE8108 PE8208 PE1216/PE2220 PE1324/PE2340 PE5220s PE5340s PE6216 PE6324 PE7214 PE7328 PE8216 PE8324 PE9222 PE9330 Rack Space 1U 1U 0U 0U 0U 0U 0U 0U /20 24/40 20/40 16/24 14/28 16/24 22/30 Remote Power Control V V V V V Metering Capability PDU Level, PDU Level Bank Via EC1000 EC2004 Bank, PDU Level Bank, PDU Level, Bank, PDU Level,, Bank, Bank, PDU PDU Level Level Environment Monitoring V V V V V V V eco Sensors Support V V Via EC1000 EC2004 V V V V V Proactive Overload Protection V V V Critical Load V
3 EC1000/EC2004 PE1216/PE1324 PE2220/PE2340 PE s PE s Energy PDU PE1216/PE1324/PE2220/PE2340 The Energy PDU contains 16/24/20/40 AC outlets and is available in various IEC or NEMA socket configurations. It features a space-saving 0U design that allows it to be mounted vertically on the outside of the rack, resulting in a more efficient use of server room space. Space saving 0U rack mount design IEC or NEMA outlet models Energy Box EC1000/EC2004 NRGence Energy Box is an intelligent 1U (0U vertical hook also available) power monitor unit which can monitor the current from 4 Energy PDUs and 4 temperature, humidity, or differential pressure sensors. It is a standalone Over IP monitor box that can be controlled by Web UI or eco Sensors software. Conveniently deploying Energy Boxes in your rack, connected to Energy PDUs, allows all current information from the PDUs to be collated and displayed on the Energy Box for easy viewing and monitoring. 4 Energy Sensor ports for Energy PDU current monitoring ( 0A to 32A per port ) 4 Environment Sensor ports for temperature, humidity and differential pressure monitoring Space saving 0U/1U rack mount design Remote real-time current management and monitoring Current threshold level setting provision Name assignment to individual PDU Wide Management Option Range Remote management via IP network with Web Brower, eco Sensors software or 3rd party SNMP manager Exceed threshold alert through Local: audio alarm and LED light blinking Remote: SMTP/SNMP trap/syslog Setup Function EC1000 EC2004 Inlet Power Adapter DC 5V (1.8m) Power Adapter DC 5V (1.8m) Current Monitor Environment Monitor 4 x Energy Sensor Connection port 4 x Environment Sensor Connection port 2xCurrent+2xCurrent/Voltage Energy Sensor Connection Port 4xEnvironment Sensor Connection Port LAN 1 x RJ-45 Female with LEDs 1xRJ-45 Female with LEDs Monitoring Range V; 50/60Hz; 0A to 32A (per port) LED Display Resolution 0.1A Accuracy: ±0.1A@0 ~ 1A, ±1%@ >1A V; 50/60Hz; 0A to 32A (per port) LED Display Resolution 0.1A Accuracy: ±0.1A@0 ~ 1A, ±1%@ >1A Rack Space Input Voltage Derated Max Input Plug # of Bank Control Meter Certification PE1216A 0U V 16A 20A NEMA5-20P 1x20A 16xNEMA5-15R None Bank x 1 FCC, ctuvus, TUV-PSE PE1216B 0U V 16A 20A NEMA6-20P 1x20A 16xIEC 320 C13 None Bank x 1 FCC, ctuvus, TUV-PSE PE1216G 0U V 16A 16A IEC C20 1x16A 16xIEC 320 C13 None Bank x 1 CE, TUV-CB, TUV, C-Tick, GOST PE1324B 0U V 24A 30A NEMAL6-30P 2x15A 24xIEC 320 C13 None Bank x 2 FCC, ctuvus, TUV-PSE PE1324G 0U V 32A 32A IEC A 2x16A 24xIEC 320 C13 None Bank x 2 CE, TUV-CB, TUV, C-Tick, GOST PE2220A 0U V 16A 20A NEMA5-20P 1x20A 20xNEMA5-15R None Bank x 1 CE-LVD, TUV-CB, Others by request PE2220B 0U V 16A 20A NEMA6-20P 1x20A PE2220G 0U V 16A 16A IEC C20 1x16A PE2340B 0U V 24A 30A NEMAL6-30P 2x15A PE2340G 0U V 24A 32A IEC A 1x16A The specification and pictures are subject to change without notice. 10xDuplex Receptacles IEC320 C13 10xDuplex Receptacles IEC320 C13 20xDuplex Receptacles IEC320 C13 20xDuplex Receptacles IEC320 C13 None Bank x 1 FCC, TUV-CB, Others by Reuest None Bank x 1 CE-LVD, TUV-CB, Others by request None Bank x 2 FCC, TUV-CB, Others by Reuest None Bank x 2 CE-LVD, TUV-CB, Others by request
4 PE6108/PE6208 PE8108/PE8208 PE s 1U PE s 1U PE s 1U PE s 1U Power Distribution Space saving rack mount design with rear mounting IEC or NEMA outlet models 3 x 7 segment front panel LED shows Current / IP Address Remote users can monitor outlet status via web pages on their browsers Safe shutdown support Separate power for the unit's own power and its power outlets the user interface is still accessible even when an overload condition trips the devices' circuit breakers Remote Access Remote power control via TCP/IP and a built in 10/100 Ethernet port Network Protocols: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, auto sense, Ping eco PDU Power Management software eco Sensors Supports SNMP Manager V1, V2 & V3 Operation Remote power outlet control (On, Off, Power Cycle) by individual outlets Supports multiple power control methods Wake on LAN, System After AC Back, Kill the Power Power-on sequencing - users can set the power on sequence and delay time for each outlet to allow equipment to be turned on in the proper order Easy setup and operation via a browser-based user interface Multibrowser support (IE, Firefox, Chrome, Safari) RTC support to keep the timer running during times of no power Supports up to 8 user and 1 administrator accounts Proactive overload protection(pop) automatically powers off the last outlet that caused the current overload Patent Pending!(PE8 only) Real-time current, voltage, and kwh displayed in a browsed-based UI for monitoring at the PDU level Environment monitoring supports external temperature / temperature & humidity sensors for rack temperature and humidity monitoring Current, voltage, power dissipation, energy consumption, temperature, and humidity threshold level setting Naming support for outlets User outlet access assignment on an outlet-by-outlet basis Event logging and syslog support Supports Management Information Base (MIB) files for SNMP Upgradeable firmware Multilanguage support Security Two-level password security Strong security features include strong password protection and advanced encryption technologies 128 bit SSL Remote authentication support: RADIUS Management Power status measurement at PDU level or PDU level (PE8108/PE8208) LED indicators for current and IP address at the PDU device level Rack Space Input Voltage Derated Max Input Plug # of Bank Control PE6108A 1U V 12A 15A NEMA5-15P 1x15A 8xNEMA5-15R Yes Bank x 1 FCC, UL, PSE PE6108B 1U V 12A 15A NEMA6-15P 1x15A 8xNEMA6-15R Yes Bank x 1 FCC, UL, PSE Meter Certification PE6108G 1U V 10A 10A IEC C14 1x10A 8xIEC 320 C13 Yes Bank x 1 CE, TUV-CB, TUV, C-Tick, GOST PE6208A 1U V 16A 20A NEMA5-20P 1x20A 8xNEMA5-20R Yes Bank x 1 FCC, UL, PSE PE6208B 1U V 16A 20A NEMA6-20P 1x20A 7xIEC 320 C13+1xIEC 320 C19 Yes Bank x 1 FCC, UL, PSE PE6208G 1U V 16A 16A IEC C20 1x16A 7xIEC 320 C13+1xIEC 320 C19 Yes Bank x 1 CE, TUV-CB, TUV, C-Tick, GOST PE8108A 1U V 12A 15A NEMA5-15P 1x15A 8xNEMA5-15R Yes FCC, UL, PSE PE8108B 1U V 12A 15A NEMA6-15P 1x15A 8xNEMA6-15R Yes FCC, UL, PSE PE8108G 1U V 10A 10A IEC C14 1x10A 8xIEC 320 C13 Yes CE, TUV-CB, TUV, C-Tick, GOST PE8208A 1U V 16A 20A NEMA5-20P 1x20A 8xNEMA5-20R Yes FCC, UL, PSE PE8208B 1U V 16A 20A NEMA6-20P 1x20A 7xIEC 320 C13+1xIEC 320 C19 Yes FCC, UL, PSE PE8208G 1U V 16A 16A IEC C20 1x16A 7xIEC 320 C13+1xIEC 320 C19 Yes CE, TUV-CB, TUV, C-Tick, GOST The specification and pictures are subject to change without notice.
5 PE5220s/PE5340s PE6216/PE6324 PE5220s 20 s PE5340s 40 s PE s PE s Power Distribution Space saving rack mount design with rear mounting IEC or NEMA outlet models 3 x 7-segment front panel LED shows Current / IP Address for PDU / Bank Remote users can monitor PDU/Bank status via web pages on their browsers Safe shutdown support Separate power for the unit's own power and its power outlets - the user interface is still accessible even when an overload condition trips the devices' circuit breaker Remote Access * Remote power control via TCP/IP and a built in 10/100 Ethernet port Network Protocols: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, auto sense, Ping eco PDU Power Management software eco Sensors Supports SNMP Manager V1, V2 & V3 Real-time aggregate current, voltage, and power and power dissipation displayed in a browser-based UI for monitoring at the PDU level (PE5216/PE6216) and at the bank level (PE5324/PE6324) Environment monitoring supports external temperature / humidity / Differential Pressure sensors for rack environment monitoring Current and voltage threshold setting Naming support for outlets * User outlet access assignment on an outlet-by-outlet basis Event logging and syslog support Upgradeable firmware Multilanguage support: English, Traditional Chinese, Simplified Chinese, Japanese, German, Italian, Spanish, French, Russian Security Two-level password security Strong security features include strong password protection and advanced encryption technologies 128 bit SSL Remote authentication support: RADIUS Operation * Remote power outlet control (On, Off, Power Cycle) by individual outlets * Supports multiple power control methods Wake on LAN, System After AC Back, Kill the Power * Power-on sequencing users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order Easy setup and operation via a browser-based user interface Multibrowser support (IE, Mozilla, Firefox, Chrome, Safari, Opera, Netscape) RTC support to keep the timer running during times of no power. Up to 8 user accounts and 1 administrator account. Management Power status measurement at the PDU/Bank level LED indicators for current and IP address at the PDU device and/or Bank levels *Features supported by PE6216/PE6324 only Rack Space Input Voltage Derated Max Input Plug # of Bank Control Meter Certification PE5220sA 0U V 16A 20A NEMA5-20P 1x20A 20xNEMA5-15R None Bank x 1 FCC, TUV-CB, Others by request PE5220sB 0U V 16A 20A NEMA6-20P 1x20A 20xIEC 320 C13 None Bank x 1 FCC, TUV-CB, Others by request PE5220sG 0U V 16A 16A IEC C20 1x16A 20xIEC 320 C13 None Bank x 1 CE, TUV-CB, Others by request PE5340sB 0U V 24A 30A NEMAL6-30P 2x15A 40xIEC 320 C13 None Bank x 2 FCC, TUV-CB, Others by request PE5340sG 0U V 32A 32A IEC A 2x16A 40xIEC 320 C13 None Bank x 2 CE, TUV-CB, Others by request PE6216A 0U V 16A 20A NEMA5-20P 1x20A 14xNEMA5-15R+2xNEMA5-20R Yes Bank x 1 FCC, ctuvus, TUV-PSE PE6216B 0U V 16A 20A NEMA6-20P 1x20A 14xIEC 320 C13+2xIEC 320 C19 Yes Bank x 1 FCC, ctuvus, TUV-PSE PE6216G 0U V 16A 16A IEC C20 1x16A 14xIEC 320 C13+2xIEC 320 C19 Yes Bank x 1 CE, TUV-CB, TUV, C-Tick, GOST PE6324B 0U V 24A 30A NEMAL6-30P 2x15A 21xIEC 320 C13+3xIEC 320 C19 Yes Bank x 2 FCC, ctuvus, TUV-PSE PE6324G 0U V 32A 32A IEC A 2x16A 21xIEC 320 C13+3xIEC 320 C19 Yes Bank x 2 CE, TUV-CB, TUV, C-Tick, GOST The specification and pictures are subject to change without notice.
6 PE7214/PE7328 PE8216/PE8324 PE9222/PE9330 PE s PE s PE s PE s PE s PE s Power Distribution Space saving rack mount design IEC or NEMA outlet models Remote users can monitor outlet status via web pages on their browsers Safe shutdown support Separate power for the unit's own power and its power outlets the user interface is still accessible even when an overload condition trips the devices' circuit breakers Remote Access Remote power control via TCP/IP and a built in 10/100 Ethernet port Network Interfaces: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, auto sense, Ping eco PDU Power Management software eco Sensors Supports SNMP Manager V1, V2 & V3 User outlet access assignment on an outlet-by-outlet basis Event logging and syslog support Supports Management Information Base (MIB) files for SNMP Upgradeable firmware Multi-language support Proactive overload protection(pop) automatically powers off the last outlet that caused the current overload Patent Pending! (PE8/PE9 only) Security Two-level / Three-level password security Strong security features include strong password protection and advanced encryption technologies 128 bit SSL Remote authentication support: RADIUS Operation Remote power outlet control (On, Off, Power Cycle) by individual outlets and outlet groups Supports multiple power control methods Wake on LAN, System After AC Back, Kill the Power Power-on sequencing - users can set the power on sequence and delay time for each outlet to allow equipment to be turned on in the proper order Easy setup and operation via a browser-based user interface Multibrowser support (IE, Firefox, Chrome, Safari) RTC support to keep the timer running during times of no power Supports up to 8 user and 1 administrator accounts Critical load outlet keeps power always on for critical load devices ( PE9 only ) Management Power status measurement at PDU and outlet levels Current, voltage, power dissipation, and energy consumption displayed in a browser based UI for monitoring at the outlet, group, PDU levels Environment monitoring supports external temperature / temperature & humidity sensors for rack temperature and humidity monitoring Current, voltage, power dissipation, energy consumption, temperature, and humidity threshold level setting Naming support for outlets and outlet groups *PE7 is always on. Rack Space Input Voltage Derated Max Input Plug # of Bank Control Meter Certification PE7214B 0U V 16A 20A NEMA6-20P 1x20A 12xIEC 320 C13+2xIEC 320 C19 None FCC, ctuvus, TUV-PSE PE7214G 0U V 16A 16A IEC C20 1x16A 12xIEC 320 C13+2xIEC 320 C19 None CE-LVD, TUV-CB, Others by request PE7328B 0U V 24A 30A NEMAL6-30P 2x15A 24xIEC 320 C13+4xIEC 320 C19 None FCC, ctuvus, TUV-PSE PE7328G 0U V 32A 32A IEC A 2x16A 24xIEC 320 C13+4xIEC 320 C19 None CE-LVD, TUV-CB, Others by request PE8216B 0U V 16A 20A NEMA6-20P 1x20A 14xIEC 320 C13+2xIEC 320 C19 Yes FCC, ctuvus, TUV-PSE PE8216G 0U V 16A 16A IEC C20 1x16A 14xIEC 320 C13+2xIEC 320 C19 Yes CE, TUV-CB, TUV, C-Tick, GOST PE8324B 0U V 24A 30A NEMAL6-30P 2x15A 21xIEC 320 C13+3xIEC 320 C19 Yes FCC, ctuvus, TUV-PSE PE8324G 0U V 32A 32A IEC A 2x16A 21xIEC 320 C13+3xIEC 320 C19 Yes CE, TUV-CB, TUV, C-Tick, GOST PE9222B 0U V 16A 20A NEMA6-20P 1x20A 19xIEC 320 C13+3xIEC 320 C19 Mix FCC, TUV-CB, Others by request PE9222G 0U V 16A 16A IEC C20 1x16A 19xIEC 320 C13+3xIEC 320 C19 Mix CE, TUV-CB, Others by request PE9330B 0U V 24A 30A NEMAL6-30P 2x15A 26xIEC 320 C13+4xIEC 320 C19 Mix FCC, TUV-CB, Others by request PE9330G 0U V 32A 32A IEC A 2x16A 26xIEC 320 C13+4xIEC 320 C19 Mix CE, TUV-CB, Others by request The specification and pictures are subject to change without notice.
7 A 1 Normal Unreachable Warning Critical Report Title: Sales Department IT Power Analysis Daily Report: 2011/1/1 2011/5/5 by Bill Li IT Power Usage Chart IT Power Load Chart kwh kwh - Sales Sales 4 - Sales Sales 1 1/1 2/2 3/3 4/4 5/5 1/1 2/2 3/3 4/4 5/5 IT Inventory List in Report No. Name Peak Watts Peak CO2e/Hrs Yearly Power Cost Yearly CO2e Cost Location 01 Web Server kg L25 02 Log Server kg L27 Energy & DCIM Management Software eco Sensors eco Sensors software has been developed to work with NRGence power distribution units (PDUs) to effectively increase the efficiency of data center power usage. With the use of dynamic Rack Cooling Index (RCI) and Return Temperature Index (RTI) by zone, eco Sensors software, in conjunction with sensor-enabled eco PDUs, gives you the means to assess, diagnose and estimate how much energy you can save. Following the suggestions generated by the sensor-enabled system allows you to optimize energy usage to save energy without harming your IT equipment s reliability. Automatic discovery of all PE devices within the same intranet Remote real-time power measurement and monitoring PDU level current / voltage / power dissipation / power consumption ON / OFF / Recycle status Remote real-time power outlet management* Power outlet ON / OFF / Cycle switching by outlet User-defined outlet level delays for sequential power up Current / Voltage / Power Dissipation / Power Consumption threshold level setting User access assignment for every outlet Name assignment to individual outlets Remote real-time environment sensor monitoring Temperature / Temperature + Humidity reading / Temperature + Differential Pressure Temperature and Humidity threshold level setting Plotting/Monitoring of all PE devices Add data center server racks Add PE devices for each server rack Manage device/device outlet status for each plot Offers essential data center indices including RCI( Rack Cooling Index ), RTI ( Return Temperature Index ), RHI ( Rack Humidity Index ), RPI ( Rack Pressure Index ), RAI ( Rack Airflow Index ) Power analysis report for optimizing data center energy management including power usage, power load, power cost, CO2 cost, power capacity and trend Exceed threshold alert through SMTP and System log line event log System log provision Two-level password security * Not all functions are supported by all NRGence PDU. Please see for more details. Setup Temperature Sensor Internet/ LAN Differential Pressure Sensor IT Office IT Office eco PDU Sensor Probes Server Storage Hardware Requirement Operating System Windows XP / Windows Server 2003 and later CPU 2.0 GHz Dual Core Display Larger than 1024x768 Memory 2GB Disk 300GB Network 10/100/1000 Mbp Ethernet System Parameter Max PDU number 1000 Data Center Layout 45x30 Max Rack Number 500 Max Zone Number 20 Power Report Data 3 years Real Time Dashboard Data 1 hours
8 Optional Accessories Environment Sensors Part No. Sensor Accuracy EA1140 Temperature 1 C EA1240 Temperature / Humidity 1 C, 3%RH EA1340 Differential Pressure / 1 C, 10 Pa Temperature EA1440 Photo Door Sensor EA1441 Inductive Proximity Door Sensor Mounting Kit Slide Rail Kit (2X-016G) Button Mount Kit (2X-017G) Side Mount Installation Cable Holders Part No. 2X-EA07 2X-EA08 Description Lok-U-Plug Cable Holder (10 pcs per pack) Patent Pending! Lok-U-Plug Installation Tool (4 pcs per pack) Lok-U-Plug Installation Button Mount Installation Corporate Headquarters ATEN International Co., Ltd. 3F., No.125, Sec. 2, Datong Rd., Sijhih District., New Taipei City 221, Taiwan Phone: Fax: [email protected] U.S.A. Subsidiaries: ATEN Technology Inc DaVinci, Foothill Ranch, CA 92610, U.S.A Phone: Fax: [email protected] ATEN New Jersey Inc. 155 Pierce Street, Somerset, NJ 08873, U.S.A Phone: Fax: [email protected] Belgium Subsidiary : ATEN Infotech N.V. Mijnwerkerslaan 34, 3550 Heusden-Zolder, Belgium Phone: Fax: [email protected] Japan Subsidiary : ATEN Japan Co., Ltd. ATEN Bldg. 8-4, Minami-senjyu 3-chome, Arakawa-ku, Tokyo Japan Phone: Fax: [email protected] Korea Subsidiary : ATEN Korea.,Ltd. B-303, Gabeul Great Valley, 60-5, Gasan-dong, Geumcheon-gu, Seoul, Korea; Phone: Fax: [email protected] U.K. Subsidiary : ATEN U.K. Limited 229 Berwick Avenue, Slough, SL1 4QT, U.K. Phone: Fax: [email protected] China Subsidiary : ATEN China Co., Ltd. 18/F, Tower A, Horizon International Tower, No.6, Zhichun Road, Haidian District, Beijing, China Phone: Fax: [email protected] Taiwan Subsidiary : Atech Peripherals, Inc. 6F., No.133, Sec. 2, Datong Rd., Sijhih District., New Taipei City 221, Taiwan Phone: Fax: [email protected] Copyright 2012 ATEN International Co., Ltd. ATEN and the ATEN logo are trademarks of ATEN International Co., Ltd. All rights reserved. All other trademarks are the property of their respective owners. Printed 01/2013 V5.0 PAPE-0089-K12
PE6108/PE6208/PE8108/PE8208
Energy Intelligence Solutions PE6108/PE6208/PE8108/PE8208 eco PDU Distribution Unit ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency
PE8216/PE8324. Energy Intelligence Solutions
PE8216/PE8324 As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The
PN5212/PN5320/PN7212/PN7320
PN522/PN5/PN722/PN7 Over the NET Distribution Units ALTUSEN Over the NET products are Distribution Units that offer outlet level control combined with remote access to give IT administrators the ability
eco PDU PE Series PE5216 / PE6216 / PE5324 / PE6324 Power Distribution Unit User Manual
eco PDU PE Series PE5216 / PE6216 / PE5324 / PE6324 Power Distribution Unit User Manual www.aten.com FCC Information This is an FCC Class A product. In a domestic environment this product may cause radio
www.aten.com Application Guide Digital KVM Extension Solution for Control Rooms
www.aten.com for Control Rooms Centralized Control and Management The latest management systems extensively utilize computers for data storage and processing. This expansion in the scale of management
www.aten.com Application Guide Guardian Over the NET Server Room Solution
www.aten.com Guardian Over the NET Server Room Solution Develop a Secure, Stable Server Room For security reasons, more and more companies house all their servers in a secure environment a server room
Application Guide. Matrix KVM Solution for Network Operating Center (NOC)
www.aten.com Matrix KVM Solution for Network Operating Center (NOC) Centralized Control and Management With the increasing number of servers housed in data centers, along with the operators needed to work
www.aten.com Application Guide KVM Solutions for SMB Server Rooms
www.aten.com Build a Server Room for Secure and Centralized Control Concurrent with developments in modern management systems and network applications, today's enterprise increasingly relies on the availability
www.aten.com Application Guide Matrix KVM Solution for Data Centers
www.aten.com Matrix KVM Solution for Data Centers Data Center Management Concurrent with developments in Information Technology and Network Infrastructure, more and more computers are being utilized for
8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers
BRC_PDU_US_B_BRC_IcePack 4/30/13 11:31 AM Page 2 8 Intelligent PDUs Intelligent Power Distribution Units for Data Centers Intelligent Power Distribution Units Siemon s line of intelligent PDUs provide
Energy Management Solutions
Energy Management Solutions Introducing the world s most innovative intelligent Power Distribution Units (ipdus) designed to simplify rack energy and environmental management of your data center. Enlogic
Cat 5 High-Density KVM Over the NET
KH1508Ai/KH1516Ai Cat 5 High-Density KVM Over the NET The KH1508Ai/KH1516Ai Cat 5 High-Density KVM Over the NET switches offer 8 and 16 computer port configurations in a 1U-high housing for convenient
Eaton epdu. Intelligent and flexible power distribution
Eaton epdu Intelligent and flexible power distribution Introduction and overview With today s changing technology, increasing power demands and the need for reliability, data centre professionals require
The Leading KVM Switch Solutions Provider, ATEN. 40-Port KVM Over the NET - 1 local / 4 remote user access
Seite 1 von 8 Select Language KN4140v Enterprise Solutions IPMI KVM Switches High-Density KVM Switches Matrix KVM Switches Matrix Plus LCD KVM Switches KVM Over the NET Serial Over the NET Guardian Over
Table of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7
PDU User Manual Table of Contents 1. Introduction...1 2. PDU Package...2 3. Function...3 4. Installation...5 5. Web Interface...7 1. Introduction The PDU is an Internet ready device designed and is equipped
Power Commander Power Distribution Units from Wiremold/Legrand offer
Power Commander Power Distribution Units Rack Power Distribution Solutions for IT/Network Environments Power Commander Power Distribution Units from Wiremold/Legrand offer comprehensive power distribution
KVM Over the NET. KN2124v 24 ports 1 local and 2 remote user. KN2140v 40 ports 1 local and 2 remote user. KN4124v 24 ports 1 local and 4 remote user
KVM Over the NET The KVM Over the NET switches allow local and remote operators to monitor and the entire enterprise data center over the Internet using a web-based browser. In addition, they offer out-of-band
KN1108v/KN1116v. KVM Over the NET. Enterprise Solutions
KN1108v/KN1116v KVM Over the NET The KN1108v / KN1116v is an IP-based KVM control unit, with dual IP / dual power functionality, serial console access and Virtual Media support, that allows both local
CN8000. Features. KVM on the NET
CN8000 KVM on the NET The new generation of CN8000 provides over-ip capability to KVM switches that do not have built in over-ip functionality. It allows operators to monitor and access their computers
CC2000. Control Center Over the NET Management Software
CC2000 Control Center Over the NET Management Software Physical server sales diminished in 2009 as a result of an increased migration to virtual server systems. Recently, however, due to older equipment
Enhanced capabilities of KVM over IP switches also include: a Message Board, Panel Array Mode, Mouse DynaSync, and Adapter ID.
1 KVM over IP Switches Aten s new generation of KVM over IP switches - KN series allows local and remote operators the ability to monitor and their entire data center over the network using a web-based
CN8000. KVM on the NET. Simply Better Connections
CN8000 KVM on the NET The new generation of CN8000 provides over-ip capability to KVM switches that do not have built in over-ip functionality. It allows operators to monitor and access their computers
CN8600 DVI KVM over IP
CN8600 DVI KVM over IP The CN8600 DVI KVM over IP is a cost efficient over-ip device, which allows remote access of digital video, audio and virtual media via remote control of a PC or workstation. The
Intel Core i3-2120 processor. 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.
VS-8132 Pro+ Hardware Spec. Processor HDD Capacity Intel Core i3-2120 processor 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The system is shipped without HDD. 2. For the HDD compatibility list,
Recording. http://www.qnap.com/nvr/compatibilityx01.html. Smart recording (depending on the camera models)
VS-2108L Hardware Spec. CPU Marvell 1.6GHz DRAM 512MB DDRIII RAM Flash Memory 512MB Hard Disk Drive 2 x 3.5" SATA I/II hard disk drive (HDD) NOTE: 1. The system is shipped without hard disk drives. 2.
Emerson Smart Firewall
DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy
Dominion PX. General Questions. What is Dominion PX (PX)?
Dominion PX Question General Questions What is Dominion PX (PX)? Is Raritan new to the rack power distribution unit market? Can the PX be used as a stand-alone device? Does PX work with Raritan s CommandCenter
Centralized Orchestration and Performance Monitoring
DATASHEET NetScaler Command Center Centralized Orchestration and Performance Monitoring Key Benefits Performance Management High Availability (HA) Support Seamless VPX management Enables Extensible architecture
Quad Core Intel Xeon Processor E3. 12 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.
VS-12164U-RP Pro Hardware Spec. Processor HDD Capacity Quad Core Intel Xeon Processor E3 12 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The system is shipped without HDD. 2. For the HDD compatibility
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
StruxureWare TM Center Expert. Data
StruxureWare TM Center Expert Data End to end data center infrastructure management software for monitoring and control of power, cooling, security and energy usage from the building through IT systems
KL1508Ai (KL1508AiM: 17" LCD; KL1508AiN: 19" LCD) KL1516Ai (KL1516AiM: 17" LCD; KL1516AiN: 19" LCD) 8/16-Port Dual Rail LCD KVM Switch
KL1508Ai (KL1508AiM: 17" LCD; KL1508AiN: 19" LCD) KL1516Ai (KL1516AiM: 17" LCD; KL1516AiN: 19" LCD) 8/16-Port Dual Rail LCD KVM Switch LCD Console + Cat 5 High-Density KVM Switch with KVM over IP The KL1508Ai
Rack Power Distribution. Worldwide
Rack Distribution Worldwide Introduction APC TM by Schneider Electric TM offers a wide array of standardized Rack Distribution Units (PDUs) designed to increase manageability and efficiency in your data
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
Rack Power Distribution
The Rack PDU Selector is located at: www.apc.com/tools/selector/pdu Test drive a metered or switched Rack Power Distribution Rack PDU at testdrive.apc.com 132 Fairgrounds Road West Kingston, RI 02892 Phone:
Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.
About This Guide This guide contains step-by-step instructions for setting up the D-Link DFL-260E/860E Firewall. Please note that the model you have purchased may appear slightly different from those shown
How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring
How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring Brian Rehnke e-pdu Business Development Manager November, 2011 The Problems Energy Usage in most data centers
How To Power A Bladecenter H Servers
Solutions Guide for IBM Data Center Architecture: IBM BladeCenter H Servers In today s high-demand enterprise environment, organizations need a reliable infrastructure to run compute-intensive applications
4-CH Hybrid Digital Video Recorder
4-CH Hybrid Digital Video Recorder Key Features Hardware Embedded, highly-reliable standalone HDVR Supports 4-ch BNC connectors Supports dual local display (VGA and HDMI) Supports 3.5" SATA x 1 HDD Supports
2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The standard system is shipped without HDD. 2. For the HDD compatibility list, please
VS-2104 Pro+ Hardware Spec. Processor Memory HDD Capacity Dual-core Intel processor 4GB RAM 2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The standard system is shipped without HDD. 2. For the
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
Network Power Manager. User Manual
Network Power Manager User Manual Table of Contents 1. Introduction... 1 2. PDU Package... 2 3. Function... 3 4. Installation... 4 5. Web Interface... 5 1. Introduction The PDU is an Internet ready device
Bay. Reliable, Secure, and User Friendly Personal Cloud Storage. NAS520 2-Bay Personal Cloud Storage. Benefits
2 Bay Reliable, Secure, and User Friendly Personal Cloud Storage 1.2 GHz dual-core processor with link aggregation for excellent performance It is essential in the modern connected world to access your
Cisco Virtualization Experience Client 6215
Data Sheet Cisco Virtualization Experience Client 6215 Product Overview Cisco Virtualization Experience Client 6215 (VXC 6215) is a secure, reliable thin client designed to easily integrate into your virtualized
HP UPS Management Module Overview
Overview The enables you to monitor and manage power environments through comprehensive control of HP UPSs. The can support either a single UPS configuration or provides additional power protection with
KM0532/KM0932/KM0032. Multi-Console 32-Port Matrix KVM Switch. Enterprise Solutions
Enterprise Solutions KM0532/KM0932/KM0032 Multi-Console 32-Port Matrix KVM Switch ATEN Matrix KVM Switches are designed for modern data centers that require reliable, high security access and control of
Features. Dual View The Dual View function provides support for two displays.
Dual monitor computing made easy Dual View KVMPTM Switches ATEN s advanced Dual View KVMPTM Switches allow access to computers from a single keyboard and mouse with dual displays. They provide support
StruxureWare TM Data Center Expert
StruxureWare TM Data Center Expert Infrastructure management from rack to row to room to building Deploy in minutes, manage from anywhere, analyze instantly, integrate with other management systems. End
Technical Overview CM-16 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk
Technical Overview CM-16 Climate Monitor Get yours direct at: 01491 410913 www.theclimate.co.uk Need a lot of remote sensors in a rack mount? The CM-16 has web access, graphing, and alarm alerts sent by
Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning
Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning 2009, Raritan Inc. Overview Corporate America is more dependent than ever on computing
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
Computer Cabinet Environment Monitor
Computer Cabinet Environment Monitor WxGoos-1 (03/30/2006) Individual or Multiple Cabinet Monitoring A simple, low-cost device for monitoring cabinets and racks, the WxGoos-1 contains five built-in environment
QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview
Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching capabilities? The HP Managed Power Distribution Unit
ED1259R5 Updated April 2011 For latest specs visit www.legrand.us/wiremold
Rack Power Distribution Solutions for IT/Network Environments Wiremold Power Commander Power Distribution Units offer comprehensive power distribution solutions for IT environments from networking solutions
MSNswitch: 1. Automatically Power-Cycle Unresponsive Network Devices 2. Watch-Dog for Network Devices
MSNswitch: 1. Automatically Power-Cycle Unresponsive Network Devices 2. Watch-Dog for Network Devices UIS-323f (Schuko) UIS-323g (UK) UIS-323k (Denmark) UIS-323e (French) Auto power-cycle outlet when internet
Technical Overview CM-2 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk
Technical Overview CM-2 Climate Monitor Get yours direct at: 01491 410913 www.theclimate.co.uk The importance of effectively monitoring IT environments has never been greater. There are a multitude of
Power IQ User Guide Release 2.0.0
Power IQ User Guide Release 2.0.0 Copyright 2010 Raritan, Inc. PIQ-0J-v2.0.0-E September 2010 255-80-6092-00 This document contains proprietary information that is protected by copyright. All rights reserved.
VS-4112U-RP Pro+ Hardware Spec.
VS-4112U-RP Pro+ Hardware Spec. Processor Dual-core Intel processor Memory 4GB RAM HDD Capacity 4x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive NOTE: 1. The standard system is shipped without HDD. For the
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2
Wireless Day / Night Cloud Camera TV-IP751WIC (v1.0r)
(v1.0r) TRENDnet s Wireless Day / Night Cloud Camera, model, takes the work out of viewing video over the internet. Previously to view video remotely, users needed to perform many complicated and time
Network Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
Expert Power Control NET 4x 8212 / 8213
2010 Gude Analog- und Digitalsysteme GmbH 2010 Gude Analog- und Digitalsysteme GmbH 23.08.2010 Content 3 Table of content Kapitel 1 Security Advise 5 Kapitel 2 Description 5 Kapitel 3 Hardware 6 3.1 Content
Improve competiveness of IDC and enterprise data centers with DCIM
Improve competiveness of IDC and enterprise data centers with DCIM This paper studies the implementation of modern DCIM systems for data centers to improve operational competitiveness with ATEN's DCIM
CMS-80. Advanced Digital Signage Content Management Server. Highlights. Equipped with intuitive user interface and accessible online help
Advanced Digital Signage Content Management Server CMS-80 Highlights Equipped with intuitive user interface and accessible online help Update contents to a maximum of 250 SMP players simultaneously Offer
imvision System Manager
SYSTIMAX Solutions imvision System Manager Infrastructure Management Software www.commscope.com imvision System Manager Vision imvision System Manager can provide a complete view of your physical infrastructure,
Rack Systems Solutions
Rack Systems Solutions Designed to simplify cable management and improve power distribution Engineered by APC by Schneider Electric for Dell, NetShelter S is the next-generation rack enclosure solution
CenterMind P+ Solution for efficient power management
CenterMind P+ Solution for efficient power management Overview Over last decade DC become significant power consuming facilities Information Technology Equipment (ITE) continue to increase computing capabilities
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Samsung device management solutions Manage, monitor and diagnose multiple print devices easily and cost effectively
Samsung device management solutions Manage, monitor and diagnose multiple print devices easily and cost effectively Proactively identify equipment issues before they become problems. Economically manage,
QuickSpecs. Models. HP UPS Management Module. HP UPS Management Module. Overview
Overview The enables you to monitor and manage power environments through comprehensive control of HP UPSs. The can support either a single UPS configuration or provides additional power protection with
20675 Manhattan Place Torrance CA 90501 USA T: 1-888-326-6061 F: 1-310-961-5511 [email protected] www.trendnet.com
TV-IP322WI (V1.0R) SETUP INFO UPC # 710931110524 Master Carton UPC # 10710931110521 Video Product Page Additional Images Alternate Product Name Key Search Words Unit Dimensions Unit Weight Unit Qty per
Remote Monitoring Unit SC8100. Monitoring Unit SC8100
Monitoring Unit SC8100 Remote Monitoring Unit SC8100 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with all
QuickSpecs. HP PCM Plus v4 Network Management Software Series (Retired) Key features
Overview (Retired) HP PCM+ Network Management Software is a Microsoft Windows -based network management platform that enables mapping, network and device configuration, and monitoring. HP PCM+ provides
Power & Environmental Monitoring
Data Centre Monitoring Made Easy Power & Environmental Monitoring Features & Benefits Packet Power provides the easiest, most cost effective way to capture detailed power and temperature information for
Wireless Router Setup Manual
Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,
GV-FE420. Visítenos: www.dluxsecurity.com. Cámara IP Fisheye Megapixel
GV-FE420 Introduction The GV FE420 is a fisheye camera that allows you to monitor all angles of a location using just one camera. The distorted hemispherical image of the fisheye camera will be converted
HP PCM Plus v4 Network Management Software Series
HP PCM Plus v4 Network Management Software Series Data sheet Product overview HP PCM+ Network Management Software is a Microsoft Windows -based network management platform that enables mapping, network
Introducing Tripp Lite s PowerAlert Network Management Software
Introducing Tripp Lite s PowerAlert Network Management Software What Can It Do For You? Improve the accuracy and efficiency of the network operations staff in the context of power and environmental management
Panduit Infrastructure Management Software for Data Centers and Enterprises
Panduit Infrastructure Management Software for Data Centers and Enterprises SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features: Simple
Panorama PANORAMA. Panorama provides centralized policy and device management over a network of Palo Alto Networks next-generation firewalls.
provides centralized policy and device management over a network of Palo Alto Networks next-generation firewalls. View a graphical summary of the applications on the network, the respective users, and
3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
Specifications SMART Bridgit software
PLEASE THINK BEFORE YOU PRINT Specifications SMART Bridgit software Version 4.2 Product description SMART Bridgit conferencing software is a cost-effective client/server application that lets you easily
Acano solution. Acano Solution Installation Guide. Acano. January 2014 76-1002-03-B
Acano solution Acano Solution Installation Guide Acano January 2014 76-1002-03-B Contents Contents 1 Introduction... 3 1.1 Before You Start... 3 1.1.1 Safety information... 3 1.1.2 You will need the following
How to Log On... 15 Main Screen... 18 Control Console Menus... 21. How to Log On... 24 Summary Page... 27 Navigation Menu... 29
Contents Introduction--1 Product Description.................................. 1 Access Procedures.................................... 3 How to Recover From a Lost Password..................... 6 Upgrading
ENC Enterprise Network Center. Intuitive, Real-time Monitoring and Management of Distributed Devices. Benefits. Access anytime, anywhere
Scalability management up to 2,000 devices Network and device auto-discovery Firmware upgrade/backup and device configurations Performance alerts and monitoring ZyXEL switch specialized in RMON management
Olson Electronics Remote Power Monitoring Meter
Olson Electronics Remote Power Monitoring Meter Operation Guide Key Features Amps: 00.00 to 32.00A True RMS (rated short period to 40A) Volts: 200.0 to 250.0V True RMS Watts: 0000 to 9999W KWh: 000000.0
Broadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
Packet Power. Data Center Solutions. Packet Power. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution
Data Center Solutions for Data Centers provides the easiest, most cost-effective way to capture detailed power and temperature information for both single-site and large multi-facility operations. Gain
USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE
RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE Highly efficient solutions for power distribution, management and monitoring POWER DISTRIBUTION WIRE-FREE MONITORING LEAK DETECTION Daxten provides comprehensive
mydlink One-bay Standalone NVR
Product Highlights Concurrent Viewing Record and view real-time video from up to nine cameras in the office or remotely over the Internet Easy Setup and Configuration mydlink technology enables easy setup
The Leading KVM Switch Solutions Provider, ATEN
Seite 1 von 5 Select Language CN8000 Enterprise Solutions IPMI KVM Switches High-Density KVM Switches Matrix KVM Switches Matrix Plus LCD KVM Switches KVM Over the NET Serial Over the NET Guardian Over
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
eco PDU PE Series SNMP Settings User Instructions
eco PDU PE Series SNMP Settings User Instructions www.aten.com NRGence User Help User Information Online Registration Be sure to register your product at our online support center: International North