TERMIDOR RESIDUAL TERMITICIDE and INSECTICIDE
|
|
|
- Laurel Watson
- 10 years ago
- Views:
Transcription
1 Label Page (FRONT BASE) CAUTION KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING TERMIDOR RESIDUAL TERMITICIDE and INSECTICIDE ACTIVE CONSTITUENT: 100 g/l FIPRONIL For the protection of structures from subterranean termite damage and for the control of subterranean termites and ants around domestic and commercial structures as specified in the Directions for Use Table. TO BE USED BY LICENSED PEST CONTROL OPERATORS ONLY IMPORTANT: READ THE ATTACHED BOOKLET BEFORE USE. CONTENTS: 2.5 Litres, 5 Litres. FOR SPECIALIST ADVICE IN AN EMERGENCY ONLY PHONE TOLL FREE-ALL HOURS-AUSTRALIA WIDE Page 1 of 11
2 Label Page (BACK) STORAGE AND DISPOSAL Store in the closed, original container in a cool, well-ventilated area. Do NOT store for prolonged periods in direct sunlight. Triple or (preferably) pressure rinse containers before disposal. Add rinsings to the spray tank. Do NOT dispose of undiluted chemicals on-site. If recycling replace cap and return clean containers to recycler or designated collection point. If not recycling, break, crush or puncture and bury empty containers in a local authority landfill. If no landfill is available bury the containers below 500 mm in a disposal pit specifically marked and set up for this purpose clear of waterways, desirable vegetation and tree roots. Empty containers and product should NOT be burnt. PRECAUTIONS Residents and pets should not be allowed in a room being treated. Any spills should be cleaned up before leaving the room (refer to the MSDS). Ensure all heating/air conditioning ducts, air vents, plumbing pipes, sewer lines, floor drains, heating pipes and electrical lines/conduits are known and identified before commencing any application of termiticide. Do NOT puncture or contaminate any of these. Avoid application around edible plants. RE-ENTRY PERIOD DO NOT re-enter treated areas until spray has dried. SAFETY DIRECTIONS May irritate the eyes. Avoid contact with eyes. Wash hands after use. When opening the container, preparing spray and using the prepared spray wear chemical resistant clothing buttoned to the neck and wrist and a washable hat, halffacepiece respirator with combined dust and gas cartridge and elbow-length PVC or nitrile gloves. After each day's use, wash gloves, contaminated clothing and respirator and if rubber wash with detergent and warm water. FIRST AID If poisoning occurs, contact a doctor or Poisons Information Centre, telephone Australia-wide. MSDS Additional information is listed in the Material Safety Data Sheet. CONDITIONS OF SALE All conditions and warranties rights and remedies implied by law or arising in contract or tort whether due to the negligence of BASF Australia Ltd or otherwise are hereby expressly excluded so far as the same may legally be done provided however that any rights of the Buyer pursuant to non excludable conditions or warranties of the Trade Practices Act 1974 or any relevant legislation of any State are expressly preserved but the liability of BASF Australia Ltd or any intermediate Seller pursuant thereto shall be limited if so permitted by the said legislation to the replacement of the goods sold or the supply of equivalent goods and all liability for indirect or consequential loss or damage of whatsoever nature is expressly excluded. This product must be used or applied strictly in accordance with the instructions appearing hereon. This product is solely sold for use in Australia and must not be exported without the prior written consent of BASF Australia Ltd. = Registered trademark of BASF BASF, 2009 Product Number: Batch Number: Date of Manufacture: APVMA Approval No.: 54624/2.5-5L/0809 BASF Australia Ltd ABN Level 12, 28 Freshwater Place Southbank VIC 3006 Website: Customer Service Hotline: Page 2 of 11
3 CAUTION KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING TERMIDOR RESIDUAL TERMITICIDE and INSECTICIDE ACTIVE CONSTITUENT: 100 g/l FIPRONIL For the protection of structures from subterranean termite damage and for the control of subterranean termites and ants around domestic and commercial structures as specified in the Directions for Use Table. TO BE USED BY LICENSED PEST CONTROL OPERATORS ONLY THIS BOOKLET IS PART OF THE LABEL CONTENTS: 2.5 Litres, 5 Litres. Page 3 of 11
4 (but not limited to) Coptotermes acinaciformis, Mastotermes darwiniensis, Schedorhinotermes spp. DIRECTIONS FOR USE: All States Restraints: Avoid runoff. DO NOT apply to excessively wet soils, immediately after or during heavy rain. DO NOT apply at less than label rates. DO NOT apply to internal surfaces. PEST SITUATION RATE CRITICAL COMMENTS Subterranean Pre- 600 ml in termites including Construction: 100 L water Chemical soil (0.06% a.i. treated zones mix) under and around new buildings and structures. Post- Construction: Chemical soil treated zones under and around existing buildings and structures. 600 ml in 100 L water (0.06% a.i. mix) Application by LICENSED PEST CONTROL OPERATORS: Mix the required quantity of TERMIDOR with the specified volume of water. Apply to form a continuous chemical treated zone (horizontal and vertical or as an external perimeter) around and under the structure to be protected as per AS Create a treated zone by using a combination of conventional spraying and trenching; or an approved reticulation system as listed below. Soil injection equipment (rodding) must only be used where trenching and treating the backfill is not possible or practical. Immediately following treatment, the moisture resistant membrane should be positioned over the treated zone to prevent disturbance. Chemical treated zones that have been disturbed will need to be re-treated to restore the complete treated zone. For more details refer to General Instructions. Application by LICENSED PEST CONTROL OPERATORS: Mix the required quantity of TERMIDOR with the specified volume of water. Apply to form a continuous chemical treated zone (horizontal and vertical or as an external perimeter) around and under the structure to be protected as per AS Create a treated zone by using a combination of conventional spraying and trenching, or an approved reticulation system (listed below). Soil injection equipment (rodding) must only be used where trenching and treating the backfill is not possible or practical. Application of chemical treated zones beneath concrete slabs and paths will require drilling and injection of termiticide using rodding equipment. Construction practices, soil subsidence, difficult to wet soils and other factors may create situations where the use of non-ionic wetting agents or foam generating equipment may be useful. Chemical treated zones that have been disturbed will need to be re-applied to restore the complete treated zone. For more details refer to General Instructions. Page 4 of 11
5 PEST SITUATION RATE CRITICAL COMMENTS Reticulation 600 ml in Systems 100 L water Camilleri Systems: For use in pre and post-construction, on full perimeter and sub-slab. TermX Systems: For use in full (0.06% mix) a.i. perimeter and around sub-slab penetrations. ReTerM, Altis Perimeter & termguard systems: For use as a perimeter verticle barrier treatment. Protection of poles and fence posts Nests in poles and trees Application by LICENSED PEST CONTROL OPERATORS: The system must be installed according to the manufacturer s specifications and be capable of distributing the termiticide emulsion according to the Termidor label (refer to General Instructions) and the Australian Standard AS3660 series. Mix the required quantity of TERMIDOR with the specified volume of water. Apply by pumping through the system according to the manufacturer s specifications. Use a minimum delivery volume of 100 L of emulsion per cubic metre of appropriate soil (eg: evenly compacted sandy loam soil). Delivery pipes must be placed in such a position to ensure that the requirements for both horizontal and vertical treated zones as specified in the Australian Standard AS3660 series are met. Special attention must also be afforded to the positioning of the delivery pipes to ensure that the resultant treated zone is continuous and complete. Application by LICENSED PEST CONTROL OPERATORS: Only posts and poles in contact with soil need to be treated. For existing posts and poles create a continuous TERMIDOR treated zone 450 mm deep and 150 mm wide around the post or pole by trenching and puddle treating the back-fill. Soil injection equipment (rodding) must only be used where trenching and treating the backfill is not possible or practical. Use 100 L of prepared spray per cubic metre of soil around the pole or post. Note it is impossible to treat soil at the bottom of a sound post or pole so future attack via this route cannot be ruled out. If new posts or poles are being installed, the bottom of the hole and the back-fill should be treated at installation. Application by LICENSED PEST CONTROL OPERATORS: Locate the nest by drilling holes into the pole or tree. Ensure the full dimension of the nest is known, particularly the highest extremity. Flood the nest with prepared TERMIDOR spray. Volume will vary depending on the nest size. To aid distribution throughout the nest or in areas of difficult access, the use of foam generating equipment may be useful. Drill holes should be sealed after treatment. Do not treat trees bearing edible fruit or nuts. Page 5 of 11
6 PEST SITUATION RATE CRITICAL COMMENTS Wall cavity 6 ml in 1 L of Mix the required volume of TERMIDOR in water plus treatment water foaming agent to achieve a final foam expansion ratio of 15:1. Locate the termite activity by drilling holes into the wall cavity. Foam directly into the termite carton material until saturated. Application to wall cavities behind plasterboard may result in some staining. Only apply to wall cavities where live termites are present. Termidor foaming is not designed and should not be used as a stand-alone treatment. Accordingly a continuous chemical treatment applied to the soil as per Australian Standard should be applied immediately following successful eradication of termite activity in the structure. Nuisance Ants, External areas 6 ml in 1 L of Mix the required volume of TERMIDOR in water. Treat including but not limited to: and surrounds of water domestic, surfaces 300 mm up and 300 mm out from where the building or structure touches the ground. Apply at the Argentine ant commercial, public rate of 1 L of prepared suspension per 25 lineal metres. (Linepithema humile), and industrial Pay particular attention to potential entry points, such as black house ant buildings and weep holes, cracks and crevices. Also apply to ant trails (Ochetellus glaber), structures. and where ants are active away from the nest. pedicel ant / odorous house ant (Tapinoma Structures may include retaining walls, fences, garden beds, sheds etc. spp.), Pharaoh s ant (Monomorium pharanonis), whitefooted ant (Technomyrmex albipes). Nesting ants, including but not limited to: Funnel Ant (Aphaenogaster pythia), Greenhead ants (Rhytidoponera spp.), Meat Ants (Iridomyrmex spp.), Red Imported Fire ant (Solenopsis invicta), Yellow Crazy ant (Anoplolepis gracilipes). Spot application to nests in domestic situations. Mix the required volume of TERMIDOR in water. Treat the nest entrance or mound, and where ants are active away from the nest. Apply at the rate of 1 L of prepared suspension per 16 m 2, or 60 ml per m 2. NOT TO BE USED FOR ANY PURPOSE, OR IN ANY MANNER, CONTRARY TO THIS LABEL UNLESS AUTHORISED UNDER APPROPRIATE LEGISLATION. Page 6 of 11
7 GENERAL INSTRUCTIONS ANT CONTROL TERMIDOR will control ants by direct contact and residual activity on treated surfaces. When applied as a surface spray as directed, TERMIDOR will give up to 3 months control of ants and is best applied as ant activity increases in early spring. A follow up application during summer may be required. Do NOT apply more than 2 TERMIDOR applications per year for ant control. TERMITE CONTROL Chemical treatment for termite control around existing buildings should be considered to be part of an integrated approach to reduce the risk of termite attack and should be conducted by LICENSED PEST CONTROL OPERATORS. The steps below best describe the procedure for optimum termite management: The building owner should try to minimise water entering under and around the building and improve drainage to reduce moisture accumulating in these areas. Ventilation of sub-floor areas should also be optimised to reduce moisture accumulation. The area under the floor should be kept free from debris-timber such as off-cuts of wood or firewood. Treat with a residual chemical zone treatment such as TERMIDOR in compliance with AS Regular inspections should be carried out (at least annually as recommended by AS3660 Series). If any additional subsequent building or landscaping work causes disruption to the chemical soil treated zone it must be restored to maintain protection. MIXING Half fill the spray tank with water then add the required quantity of TERMIDOR. Stir then top up the spray tank to the required volume. The use of this product in a tank mix with other insecticides is not recommended as the behaviour and efficacy of the product may be affected. Ensure equipment is free of leaks and clean from residues of other chemicals before mixing. SOIL PREPARATION Some soils will be difficult to wet (eg. heavy clay soils) and there will be a greater chance of run-off of liquid from the surface; in these situations it will be necessary to loosen the soil to allow spray solution to percolate to form the treated zone; the soil should be scarified to a depth between mm. In situations with very heavy soils the complete removal and replacement of the soil with a sandy loam type is recommended in order to form the treated zone. The replacement soil can be treated with TERMIDOR before placing into the trench via the use of appropriate soil mixing vessels. If soil replacement is not possible then the water volume should be reduced to ensure that run-off is minimised. A reduction in the water volume used should not be associated with a reduction in the mix rate of TERMIDOR the same amount of active ingredient should be applied per given area or volume of soil; an increase in concentration of termiticide will therefore be required. The tables below indicate mix rates if application volumes need to be reduced. It is not recommended that water volumes below 3 L/m 2 are used. Horizontal Treated Zones WATER RATE /m 2 DILUTION RATE CONCENTRATION APPLICATION RATE 5 L/ m ml /100 L water 0.6 g/l 3.0 gai /m 2 4 L/ m ml / 80 L water 0.75 g/l 3.0 gai/m 2 3 L/ m ml / 60 L water 1 g/ L 3.0 gai/m 2 Vertical Treated Zones WATER RATE /m 3 DILUTION RATE CONCENTRATION APPLICATION RATE 100 L/m ml /100 L water 0.6 g/l 60 gai/m 3 90 L/m ml/90 L water g/l 60 gai/m 3 80 L/m ml/80 L water 0.75 g/l 60 gai/m 3 70 L/m ml/70 L water 0.85 g/l 60 gai/m 3 Page 7 of 11
8 If the treated zone is being applied to a building on a slope a furrow should also be formed of a similar depth along the contour of the slope to prevent run-off of the termiticide. In situations where the surface is very dry or with sandy or porous soils the area will require moistening prior to application of chemical to prevent loss of chemical through piping or excessive percolation. Difficult to wet soils may create situations where the use of non-ionic wetting agents may be useful. The use of rodding equipment in heavy clay soil can result in an uneven distribution of chemical; in such situations the preferred method of installing a treated zone is to trench and back-fill. APPLICATION Treated zones to protect both new and existing buildings may be installed using a combination of conventional spraying and trenching and approved reticulation systems. Spray equipment should be calibrated to deliver a low-pressure high volume coarse spray. It is recommended the minimum thickness of any treated soil treated zone is 80 mm. Treated zones that have been disturbed by construction, excavation and other soil disturbing activities will need reapplication to restore site to original condition. Horizontal Treated Zones Horizontal treated zones are to be applied to deter termites from gaining concealed vertical access to the building substructure. Horizontal treated zones should cover all areas of soil beneath suspended floors where there is inadequate access or where there is less than 400 mm clearance. The treated zone should also be continuous beneath a concrete slab-onground or on fill. The treated zone should surround any connection between the building and the soil and completely abut any internal vertical treated zone around any substructure. Otherwise install perimeter treated zones around each individual pier, stump, penetration point and sub-structure wall. Horizontal treated zones must be a minimum depth of 80 mm. It may be necessary to loosen the soil to allow spray solution to percolate to form the treated zone; the soil should be scarified to a depth between mm. Apply 5 L of prepared TERMIDOR spray per square metre of soil. When termiticide needs to be injected through a concrete slab to create a horizontal treated zone, suitable equipment should be used to inject termiticide through pre-drilled holes. As uneven distribution of termiticide is likely when applying by this method under the slab, the application volume should be increased per square metre up to 10 L of spray solution. To ensure an even treated zone is created, it is also recommended that maximum drill spacings and minimum application volumes consistent with the following table be adopted. Use a slab injector fitted with a multi-directional tip. When applying through such structures, the rod should be held vertically at 90 to the slab and rotated during application. Ensure a strong seal with the top of the drill hole to minimise leakage and that drill holes are plugged after treatment. Soil type Hole Spacing Number of holes per square metre Heavy clays 150 mm 36 Other soils 200 mm 25 Volume per hole to achieve 10 L/m L (300 ml) (36 x 0.3 = appro x 10 L/m 2 ) 0.4 L (400 ml) (25 x 0.4 = approx 10 L/m 2 ) Foam Applications Construction practices, soil subsidence under concrete slabs and other factors may create situations where a continuous horizontal treated zone cannot be achieved using conventional liquid treatments alone. In such situations conventional liquid application methods can be supplemented through the use of foam generating equipment. Page 8 of 11
9 Litres of prepared TERMIDOR Mix Rate TERMIDOR spray 5 10 (under concrete) 600 ml/100 L of water plus 5 recommended quantity of 10 (under concrete) foaming agent 5 10 (under concrete) Foam Expansion Ratio 5:1 5:1 10:1 10:1 25:1 25:1 Volume of finished foam required/m 2 25 L 50 L 50 L 100 L 125 L 250 L If sufficient foam volumes cannot be applied to achieve the recommended rate of TERMIDOR required, apply additional prepared liquid solution to ensure the correct amount of active ingredient is present per square metre of area treated. Vertical Treated Zones Vertical treated zones are designed to deter termites from gaining concealed horizontal access to a building or structure. Apply at least 100 L of prepared spray per cubic metre of soil. Vertical treated zones should be a minimum of 150 mm wide and applied to a depth 50 mm below the top of the footing. Where a horizontal treated zone is installed, the vertical treated zone should be installed to be continuous with it. The most effective method of creating an even and continuous treated zone is by trenching and treating the soil as it is back-filled. Soil injection equipment (rodding) must only be used where trenching and treating the back-fill is not possible or practical. Trenching Excavating a trench, treating the exposed trench, back filling and treating the back-fill is the preferred method of installing a vertical treated zone. The trench needs to be a minimum of 150 mm wide and continue to at least 50 mm below the top of the footing. Assuming a 150 mm wide trench with a 300 mm distance to the top of the footing, this would equate to a 150 mm x 350 mm trench in which 5.25 L of prepared spray would be applied per lineal metre of trench. Any variation of dimensions needs to be re-calculated on the basis of applying 100 L of prepared spray per cubic metre of soil. Rodding through concrete When applying a vertical treated zone underneath a concrete obstruction (eg. a path), a soil rod with a 3 or 4 way multidirectional tip should be used. The rod should be rotated during application (90 for a 4-way tip and 120 for a 3-way tip). The tip should be inserted down as close to the footing as possible to ensure a complete vertical treated zone. Ensure that chemical is applied during insertion and withdrawal of the rod. As uneven distribution of termiticide is likely when applying by this method under concrete, the application volume should be increased to 200 L spray solution per cubic metre of soil. Rod spacing should not exceed 200 mm and application volume should be adjusted depending on soil type (as indicated in the table below) and the depth of the footing. Assuming a 300 mm depth to the top of the footing and 200 mm spaced holes, 2 L of prepared spray is to be applied per hole. Any variation of dimensions needs to be re-calculated on the basis of applying 200 L of prepared spray per cubic metre of soil. Under concrete rodding Soil type Hole spacing Volume per hole Heavy clays 150 mm 1.5 L Other soils 200 mm 2.0 L External Perimeter Treated zones An external perimeter treated zone should be a minimum of 150 mm wide, a minimum of 80 mm deep and extend not less than 50 mm below the lowest point where the construction below ground could allow concealed termite ingress (or not less than 50 mm below the top of the footing where the building fabric could allow concealed termite ingress). Application considerations should reflect the installation of vertical treated zones. Reticulation systems At the time of registering this label, the available data only allows use of: Camilleri Underslab and Perimeter Reticulation System Page 9 of 11
10 TermX Replenishment System - vertical perimeter and around sub-slab penetrations Altis Reticulation System vertical perimeter only Termguard Reticulation System vertical perimeter only. ReTerM Reticulation System vertical perimeter only. AUSTRALIAN STANDARDS Licensed Pest Control Operators installing a chemical soil treated zone around new and existing buildings should be familiar with the Australian Standard 3660 series, which provides information relating to installation of chemical soil termite treatment zones. PERIOD OF PROTECTION Data currently available indicates that this product, when applied as a soil treatment around or under a building or structure in accordance with this label, will be effective against subterranean termites for a minimum period of eight years. Delayed mortality effects may be observed meaning termites may live and continue to be active several weeks after penetrating the treated zone. To re-establish the treated zone after the 8 year Period of Protection, re-application at full rates is required. The actual protection period will also be affected by factors such as termite pressure, climatic and soil conditions and subsequent soil disturbance. RE-INSPECTION As with all chemical termiticides, regular inspections (at least annually) by a competent Licensed Pest Control Operator are recommended as bridging and breaching of treated zones can occur. The need for retreatment should be determined as a result of these inspections. PROTECTION OF WILDLIFE, FISH, CRUSTACEANS AND ENVIRONMENT Highly toxic to fish and aquatic organisms. Do NOT apply to areas where surface water is present. Rinse waters and run-off from treated areas MUST be prevented from entering drains or waterways. Do NOT apply if heavy rains are expected to occur within 48 hours of application. Do NOT contaminate streams, rivers or waterways with the chemical or used containers. Dangerous to bees. PROTECTION OF PETS AND LIVESTOCK Before spraying remove animals and pets from the areas to be treated. Cover or remove any open food and water containers. Cover or remove (as applicable) fish ponds, aquariums etc before spraying. STORAGE AND DISPOSAL Store in the closed, original container in a cool, well-ventilated area. Do NOT store for prolonged periods in direct sunlight. Triple or (preferably) pressure rinse containers before disposal. Add rinsings to the spray tank. Do NOT dispose of undiluted chemicals on-site. If recycling replace cap and return clean containers to recycler or designated collection point. If not recycling, break, crush or puncture and bury empty containers in a local authority landfill. If no landfill is available bury the containers below 500 mm in a disposal pit specifically marked and set up for this purpose clear of waterways, desirable vegetation and tree roots. Empty containers and product should NOT be burnt. PRECAUTIONS Residents and pets should not be allowed in a room being treated. Any spills should be cleaned up before leaving the room (refer to the MSDS). Ensure all heating/air conditioning ducts, air vents, plumbing pipes, sewer lines, floor drains, heating pipes and electrical lines/conduits are known and identified before commencing any application of termiticide. Do NOT puncture or contaminate any of these. Avoid application around edible plants. RE-ENTRY PERIOD DO NOT re-enter treated areas until spray has dried. SAFETY DIRECTIONS May irritate the eyes. Avoid contact with eyes. Wash hands after use. When opening the container, preparing spray and using the prepared spray wear chemical resistant clothing buttoned to the neck and wrist and a washable hat, half-facepiece respirator with combined dust and gas cartridge and elbow-length PVC or nitrile gloves. After each day's use, wash gloves, contaminated clothing and respirator and if rubber wash with detergent and warm water. Page 10 of 11
11 FIRST AID If poisoning occurs, contact a doctor or Poisons Information Centre, telephone Australia-wide. MSDS Additional information is listed in the Material Safety Data Sheet. CONDITIONS OF SALE All conditions and warranties rights and remedies implied by law or arising in contract or tort whether due to the negligence of BASF Australia Ltd or otherwise are hereby expressly excluded so far as the same may legally be done provided however that any rights of the Buyer pursuant to non excludable conditions or warranties of the Trade Practices Act 1974 or any relevant legislation of any State are expressly preserved but the liability of BASF Australia Ltd or any intermediate Seller pursuant thereto shall be limited if so permitted by the said legislation to the replacement of the goods sold or the supply of equivalent goods and all liability for indirect or consequential loss or damage of whatsoever nature is expressly excluded. This product must be used or applied strictly in accordance with the instructions appearing hereon. This product is solely sold for use in Australia and must not be exported without the prior written consent of BASF Australia Ltd. = Registered trademark of BASF BASF, 2009 FOR SPECIALIST ADVICE IN AN EMERGENCY ONLY PHONE TOLL FREE-ALL HOURS-AUSTRALIA WIDE BASF Australia Ltd ABN Level 12, 28 Freshwater Place Southbank VIC 3006 Website: Customer Service Hotline: APVMA Approval No.: 54624/2.5-5L/0809 Page 11 of 11
TERMIDOR DRY TERMITICIDE & INSECTICIDE
CAUTION KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING TERMIDOR DRY TERMITICIDE & INSECTICIDE ACTIVE CONSTITUENT: 5 g/kg FIPRONIL For the control of termites and nuisance
Biflex Termiticide & Insecticide
POISON KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING Biflex Termiticide & Insecticide ACTIVE CONSTITUENT: 100 g/l BIFENTHRIN SOLVENTS: 562 g/l LIQUID HYDROCARBONS 50 g/l
Bifenthrin Termite and Insect Treatment
DATE: 10 th of September 2006 Page 1 of 14 POISON KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING DAVID GRAYS Bifenthrin Termite and Insect Treatment Active Constituents: 100
Max POISON KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING. Contents: 1 Litre GROUP 3A INSECTICIDE
File name 60678_44147_1L_IMMEDIATE_MPL_V01 Dimensions 345mm (w) x 150mm (h) Scale 100% when printed on A3 83% when printed on A4 Date 18 March 2009 POISON KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS
INFORMATION SHEET ON TERMITES & TERMITE MANAGEMENT PROCEDURES
INFORMATION SHEET ON TERMITES & TERMITE MANAGEMENT PROCEDURES IMPORTANT INFORMATION: The Australian Standard AS 3660.2 Protection of buildings from subterranean termites provides details for minimising
Proposed Minimum Subterranean Termite Treatment Standards
Proposed Minimum Subterranean Termite Treatment Standards Introduction This document is intended to serve as a model for states considering the adoption of standards for soil application of termiticides.
UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-31 31 16.13 (November 2014) -------------------------------- Preparing Activity: USACE Superseding UFGS-31 31 16 (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS
Termite Management Systems
Termite Management Systems Advisory notes for builders and homeowners. Termite Management The information provided in this publication relates to Class 1 (houses, townhouses, terrace houses etc) and Class
ULTIMATE TERMITE SOLUTION WATER BASED TERMITICIDE QUICK ACTION LONG LASTING CONTROL ELIMINATES TERMITES ODOURLESS PEOPLE, PET & PLANT FRIENDLY
ULTIMATE TERMITE SOLUTION WATER BASED TERMITICIDE QUICK ACTION LONG LASTING CONTROL ELIMINATES TERMITES ODOURLESS PEOPLE, PET & PLANT FRIENDLY TERMITES CAN DEVOUR YOUR HOME! Australia s subterranean termites
A guide to preventing structural damage
A guide to preventing structural damage Home owners guide to planning landscaping and maintenance of foundations Structural damage can result from movement in clay soils caused by varying moisture conditions
What you need to know about. Termite management
What you need to know about Termite management What is termite management? Termite management involves reducing the chances that major damage is caused to your house by termite infestations. Termites cause
TERMITE CONTROL IF YOU RE NOT ASKING FOR TERMIDOR, YOU RE ASKING FOR TROUBLE.
TERMITE CONTROL IF YOU RE NOT ASKING FOR TERMIDOR, YOU RE ASKING FOR TROUBLE. Termites can destroy your home Termites are increasingly causing major structural damage to buildings throughout Australia
DuPont Altriset. Professional Products TERMITICIDE H - KEEP OUT OF REACH OF CHILDREN
H - DuPont Altriset TERMITICIDE Professional Products For use by individuals/firms licensed or registered by the State to apply termiticide products. States may have more restrictive requirements regarding
CAUTION KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING. Merit. Turf and Ornamental Insecticide
Approved November 08, 2010 MERIT Turf and Ornamental Insecticide Page 1 of 5 CAUTION KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING Merit Turf and Ornamental Insecticide ACTIVE
TERMITE MANAGEMENT SYSTEMS
TERMITE MANAGEMENT SYSTEMS ADVISORY NOTES FOR HOMEOWNERS AND BUILDERS Protection of Buildings Against Subterranean Termites. DISCLAIMER: The information provided in this booklet is a guide only to the
Protect your most valuable assets
Protect your most valuable assets Premise eliminates termites right around your home Termites are a very serious pest in Australia, causing damage that costs hundreds of millions of dollars to repair each
PULL HERE TO OPEN. For use of optional Optigard ZT Unit Dose Dispenser, see instructions under Mixing Procedures. SCP 1170A-L4B 0706
PULL HERE TO OPEN Insecticide To be applied only by or under the supervision of commercial applicators responsible for pest control programs. For Remedial Control of Localized Infestations of Drywood Termites
How To Safely Use Hyexazol
Hymexazol -MATERIAL SAFETY DATA SHEET Manufacturer/information service: ZHEJIANG RAYFULL CHEMICALS CO.,LTD ADD: NO.113 PUXING ROAD, PUZHOU INDUSTRIAL PARK, LONGWAN DISTRICT, WENZHOU ZHEJIANG P.R. CHINA
Visual Termite Inspection Report in accordance with AS 3660.2-2000 Important Information
Pad 2/B Visual Termite Inspection Report in accordance with AS 3660.2-2000 Important Information Only structures, fences, trees etc within 50 m of the building but within the boundary of the property will
What Home Builders Need To Know About Termites: Termite-deterring Construction Practices:
Bug-Wise No. 9 Sept. 17, 2012 Office: 1-662-325-2085 What Home Builders Need To Know About Termites: There are a lot of important details that must be taken care of when building a new home. To build a
Specimen BASF TERMITICIDE/ INSECTICIDE
TERMIDOR SC TERMITICIDE/ INSECTICIDE Specimen For use by individuals/firms licensed or registered by the state to apply termiticide products. ACTIVE INGREDIENTS: Fipronil: 5-amino-1-(2,6-dichloro-4-(trifluoromethyl)
We re about to build.
We re about to build. Get out there boys! every new home is a possible new dinner menu! What do we need to know about dealing with termites? A Managed Approach is Best! There are more than three hundred
Bayer Environmental Science A Business Group of Bayer CropScience Pty Ltd ABN 87 000 226 022 Address:
1. IDENTIFICATION OF THE SUBSTANCE / MIXTURE AND SUPPLIER Product name: Other names: None Product code: AE F160730 00 EW02 A1 Recommended An aqueous concentrate insect growth regulator insecticide use:
TERMITE & CARPENTER ANT killer
TERMITE & CARPENTER ANT killer Concentrate CONTROLS: Subterranean Termites, Carpenter Ants, Wood-Infesting Beetles, Ants, Crickets, Earwigs, Fleas, Fire Ants, House Flies, Mosquitoes, Ticks and Wasps.
Clayton South Report Prepared: 1 February 2015 TIMBER PEST REPORT. Portfolio Includes: Timber Pest Report
Clayton South Report Prepared: 1 February 2015 TIMBER PEST REPORT Portfolio Includes: Timber Pest Report TIMBER PEST REPORT This report is the result of a VISUAL INSPECTION ONLY. Inspection of the subject
Delegate CAUTION. Insecticide KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING. ACTIVE CONSTITUENT: 250 g/kg SPINETORAM
CAUTION KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING Delegate Insecticide ACTIVE CONSTITUENT: 250 g/kg SPINETORAM For the control of various caterpillar pests, such as codling
EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS
NMP 1.4 EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS Index Purpose... 2 Application... 2 Referral Agency... 2 Associated Requirements... 2 Referenced Standards...2 Definitions...
16. Storm water drainage
16. Storm water drainage There are three principal ways to dispose of rainwater from roofs, courtyards and paved areas: storm water sewers, soakaways and collection in storage tanks. Storm water sewers,
Termites: How to Reduce Your Home's Risk of Infestation
Ohio State University Fact Sheet Entomology 1991 Kenny Road, Columbus, OH 43210-1000 Termites: How to Reduce Your Home's Risk of Infestation HYG-2092C-00 Susan C. Jones, Ph.D. Assistant Professor of Entomology
POISON KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING FOR ANIMAL TREATMENT ONLY. As an aid in the control of bloat.
Front Panel POISON KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING FOR ANIMAL TREATMENT ONLY * AF1404 Rumensin 100 Monensin Sodium ACTIVE CONSTITUENT: 100 g/kg MONENSIN (as
ACTIVE CONSTITUENT: 750 g/kg CHLORPYRIFOS (an anticholinesterase compound)
POISON KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFE OPENING USING Lorsban 750 WG Insecticide ACTIVE CONSTITUENT: 750 g/kg CHLPYRIFOS (an anticholinesterase compound) For control of certain
DRAFT TERMITE PROTECTION IN BUILDINGS
DRAFT TERMITE PROTECTION IN BUILDINGS Protection of homes and businesses from termites in Florida requires the combined efforts of builders, pest management professionals, and building inspectors. The
Properly maintaining your septic system will help reduce the. It s Your Septic System. Homeowner s Guide. Here s How to Take Care of It
Homeowner s Guide for Maintenance and Care of On-Site Sewage Systems It s Your Septic System Here s How to Take Care of It Properly maintaining your septic system will help reduce the possibility of health
BASEMENT FLOODING. Prevention Guide for. Homeowners
BASEMENT FLOODING Prevention Guide for Homeowners 1 Did You Know? Floods are the most common hazards in Canada. Water damage is a common cause of loss for homeowner insurance. A heavy rainfall can result
Dormant Season. Of Dormant Oil Spray Apple scab, Pear scab, Powdery mildew. pre-pink, pink, calyx, 1st & 2nd cover spray.
99/2004 CLEAN CROP(R) LIME SULPHUR Lime Sulphur Insecticide Miticide Fungicide COMMERCIAL CAUTION CORROSIVE READ THE LABEL BEFORE USING REGISTRATION NO. 16465 PEST CONTROL PRODUCTS ACT GUARANTEE: Sulphide
DuPont(TM) Altriset(R) termiticide
This SDS adheres to the standards and regulatory requirements of Australia and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
Preventing water damage in the basement
Preventing water damage in the basement Thousands of home insurance claims are filed every year. Some losses are major, others aren t, but they re always an inconvenience and usually avoidable! As prevention
A Guide To The New Termite Standards (revised 09/02/2001)
Building Certifiers Building Designers rchitects Guide To The New Termite Standards (revised 09/02/2001) Introduction On 1 January 2001, the Building Code of ustralia (BC) was amended to incorporate new
Termite Control in the Home
Engineered Home Inspections, PLLC Phillip Moss, P.E. www.engineeredhi.com TREC License #21634 TBPE License #110140 214-403-9146 [email protected] Termite Control in the Home Wood-destroying insects and
MATERIAL SAFETY DATA SHEET Coopex EC Residual Insecticide
1. IDENTIFICATION OF THE SUBSTANCE / MIXTURE AND SUPPLIER Product name: Other names: None Product code: AE F032639 00 EC12 A4 Recommended use: A general purpose residual insecticide for general pest control
Tree Pits Operation & Maintenance Guide
Tree Pits Operation & Maintenance Guide What are tree pits? Tree pits collect stormwater runoff from small carpark areas or roads. Runoff filters through the tree roots and surrounding soil mix, trapping
1-800-273-6050 ~ Tel: 201-865-7799 ~ Fax: 201-348-4015 SUBTERRANEAN TERMITE CONTROL SPECIFICATIONS TERMITE PROTECTION AGREEMENT
SERVICE ADDRESS BILLING INFO. (If Different) SUBTERRANEAN TERMITE CONTROL SPECIFICATIONS INTERIOR TREATMENT q Drill interior concrete floors along perimeter, treat & re-cement. q Drill interior concrete
BUILDER S GUIDE FOR TERMITE MANAGEMENT
Master Builders Technical TECH01 12/2004 BUILDER S GUIDE FOR TERMITE MANAGEMENT THIS TECHNICAL CIRCULAR HAS BEEN PREPARED TO ASSIST BUILDERS TO UNDERSTAND THE OPTIONS NOW AVAILABLE FOR COMPLIANCE WITH
Residential Foundations and Basements
Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article
PAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL
PAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL CONTENTS: 1.0 AWARENESS AND PRECAUTION 2.0 TEST SAMPLING & REMOVAL EVALUATION 3.0 SITE EVALUATION 4.0
Eco Solutions Pest Control - Sydney Tel. 02 8399 0899 PO Box 1289, Double Bay, Sydney NSW www.ecosolution.com.au
Your home has termites. Those four little words can make you feel worried, stressed out even vulnerable. After all, your home is at risk for serious and expensive damage that could turn your biggest investment
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
Chapter 3 CULVERTS. Description. Importance to Maintenance & Water Quality. Culvert Profile
Chapter 3 CULVERTS Description A culvert is a closed conduit used to convey water from one area to another, usually from one side of a road to the other side. Importance to Maintenance & Water Quality
RESIDENTIAL HARDWOOD WARRANTIES
RESIDENTIAL HARDWOOD WARRANTIES Limited Warranties for Prefinished Solid and Engineered Hardwood Floors Manufacturing Defects Century Flooring* ("Century") hereby warrants to the original buyer ("Buyer"),
What Homebuilders Need To Know About Termites
What Homebuilders Need To Know About Termites There are a lot of important details to take care of when you build a new home. To construct a building that will last, you must do certain things at the right
Termiticide Use Restrictions in Delaware
Delaware Department of Agriculture Pesticide Compliance 2320 S. DuPont Hwy., Dover, DE 19901 Tel. (302) 698-4571 Fax (302) 697-4483 (800) 282-8685 DE Only Termiticide Use Restrictions in Delaware Prepared
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
Havoc Rodenticide Bait Packs (Pellets) Kills Rats and Mice
2014-2373 2014-08-13 HACCO, INC. 110 Hopkins Drive NET CONTENTS: 50 g Place Pack s Randolph, WI 53956 READ THE LABEL AND CARTON BEFORE USING Tel: 1-920-326-5141 REGISTRATION NO: 31137 Havoc Rodenticide
LIME SULPHUR INSECTICIDE MITICIDE FUNGICIDE COMMERCIAL DANGER: CORROSIVE TO EYES READ THE LABEL AND ATTACHED BOOKLET BEFORE USING
datapak group M fungicide LIME SULPHUR INSECTICIDE MITICIDE FUNGICIDE COMMERCIAL DANGER: CORROSIVE TO EYES READ THE LABEL AND ATTACHED BOOKLET BEFORE USING REGISTRATION NO. 16465 PEST CONTROL PRODUCTS
Foundation. Foundation
Moisture Aside from structural concerns, the most important consideration for foundation design is moisture. No client wants a wet basement. No client wants a damp basement. No client wants mold in their
BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY
MURRAY SHIRE COUNCIL BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY ADOPTED: 1 May 2012 1 BUILDING OVER OR NEAR WATER AND SEWER MAINS POLICY CONTENTS 1. Objective... 2 2. Requirements for Building Near
SAFETY DATA SHEET. Trade name: Master Clear Seal-5 Revised: 5/29/2015
MMG Mud Masters Group a division of Horizon Mud Company SAFETY DATA SHEET SECTION 1: Identification of the substance/mixture and of the company/undertaking Trade name: Master Clear Seal-5 Supplied by:
DISTANCE. Insect Growth Regulator for control of whiteflies on greenhouse ornamentals and greenhouse vegetables (tomatoes, peppers, cucumbers)
DISTANCE Insect Growth Regulator for control of whiteflies on greenhouse ornamentals and greenhouse vegetables (tomatoes, peppers, cucumbers) COMMERCIAL GUARANTEE: Pyriproxyfen... 103 g/l REGISTRATION
Prevention. Cause. Causes: Groundwater seepage through the basement walls. Prevention: OPEN 24 Hours. Surface runoff. Sanitary sewer backup
U n d e r s t a n d i n g B a s e m e n t F l o o d i n g Cause hen a basement floods, it is a source of stress and frustration for everyone involved. The City of Lansing wants to be a resource of information
Termite Baiting System Reference Manual
Termite Baiting System Reference Manual Introduction Contents On-Ground Stations Why On-Ground?...4 Where should they be placed?...5 Inspecting On-Ground Stations...6 In-Ground Stations Why In-Ground?...7
Visual Termite Inspection Report in accordance with AS 3660.2-2000
Visual Termite Inspection Report in accordance with AS 3660.2-2000 Account to: File No. /Ref: Phone: Fax / Email: Client: Agreement No / Job No: Purchaser: Vendor: Property address: Date and time of the
Protect Your Home From Flooding. A guide for Lethbridge Residents
Protect Your Home From Flooding A guide for Lethbridge Residents Every year, millions of litres of water flow into the City of Lethbridge s stormwater and wastewater collection systems from residential
State of Connecticut Department of Public Health RADON PROGRAM
State of Connecticut Department of Public Health RADON PROGRAM Scope The Connecticut Department of Public Health (DPH) Radon Program is providing this information for contractors who decide to build radon
Consumer Aid for Post Construction Contracts and Termite Treatments
State of Florida Department of Agriculture and Consumer Services Consumer Aid for Post Construction Contracts and Termite Treatments A Guide for Residential Homeowners Bureau of Inspection and Incident
Release: 1. CPCCWP3004A Apply waterproofing remedial processes
Release: 1 CPCCWP3004A Apply waterproofing remedial processes CPCCWP3004A Apply waterproofing remedial processes Modification History Not Applicable Unit Descriptor Unit descriptor This unit of competency
Integrated Pest Management Policy for Research Laboratories
Integrated Pest Management Policy for Research Laboratories Environmental Health & Safety I. POLICY The University of South Carolina s Integrated Pest Management Policy is based on the CDC s Biosafety
Mineral waterproof coating PCI Dichtschlämme
Mineral waterproof coating PCI Dichtschlämme 305 for basement walls, swimming pools and potable water tanks With official test certificate. FIELDS OF For indoor and outdoor use. For walls and floors. For
Permeable Pavement Construction Guide
Permeable Pavement Construction Guide Permeable pavement at Olympic Park, Waitakere Final Construction result What are permeable pavements? Permeable pavements are hard surface paving systems that reduce
City of Green Bay Department of Public Works Engineering Department
City of Green Bay Department of Public Works Engineering Department The Difference Between Sanitary & Storm Sewers Contact Information: Department of Public Works City Hall 100 North Jefferson Street,
REGISTRATION NO: 28672 PEST CONTROL PRODUCTS ACT
2006-0359 08-NOV-2007 Page 1 of 5 COMMERCIAL ACTINOVATE SP FUNGICIDE For suppression of Botrytis fruit rot (Botrytis cinerea) and powdery mildew (Sphaerotheca macularis) on field and greenhouse strawberry,
A quick guide to our floodcare scheme
A quick guide to our floodcare scheme What to do in case of sewer flooding We re here to help We appreciate that dealing with the results of sewage flooding is always unpleasant and we know how upsetting
Basement Moisture Problems
Foundations Foundation Purpose The purpose of a foundation is to distribute the weight of a structure securely into the ground. Engineering data regarding soil, rock and water conditions are used to design
bout your HOUSE before you start Renovating Your Basement Moisture Problems
A bout your HOUSE before you start Renovating Your Basement Moisture Problems CE 28 c Condensation of cold surfaces, efflorescence Water leak in corner on floor Mold and decay on floor joists and sill
R E S I D E N T I A L H O U S I N G
HL 252 Rev. April 1997 R E S I D E N T I A L H O U S I N G CONTROLLING EXTERNALWATER PROBLEMS FOR RESIDENCES I II III IV V Lot Drainage Gutter Water Management Foundation Waterproofing Floor Slab Waterproofing
Soils, Foundations & Moisture Control
Soils, Foundations & Moisture Control Soil The top loose layer mineral and/or organic material on the surface of the Earth that serves as a natural medium for the growth of plants and support for the foundations
Principles of Pest Control
Principles of Pest Control Q. What is the first thing you should do when you detect the presence of a pest that you think you may need to control? Identify the pest to be sure you know exactly what the
Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors
Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes
Protect your home from termites
Protect your home from termites FT030 July 2003 www.fairtrading.nsw.gov.au C ontents Additional copies This publication can be viewed or printed from the Publications page of our Web site at: www.fairtrading.nsw.gov.au
Systemic. Granules. Insect Control. Protects against damaging insects for up to 8 weeks CAUTION. Root Weevils. Birch Leaf Miner.
Systemic Granules Insect Control Protects against damaging insects for up to 8 weeks Root Weevils Birch Leaf Miner Beetles Internal insect protection won t wash off with rain or water For use outdoors
MATERIAL SAFETY DATA SHEET. PCT International Pty Ltd ABN 44 101 170 923 Unit 1 / 74 Murdoch Circuit, ACACIA RIDGE QLD 4110.
PCT International Pty Ltd ABN 44 101 170 923 Unit 1 / 74 Murdoch Circuit, ACACIA RIDGE QLD 4110 [email protected] Ph: 61 7 3711 7022 Fax: 61 7 3711 7055 Termstar Termiticide and Insecticide Classified as
Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems
Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems The septic tank-absorption field sewage treatment system is composed of two major elements; the
City of Shelbyville Site Inspection Checklist
City of Shelbyville Site Inspection Checklist General Information Project Name: KYR10 Permit Number: Date: Project Location: Contractor: Conractor Representative: Inspector's Name: Title: Signature : Weather
Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations
SWPPP for Park Operations 2 Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations Bordered by Lake Washington & Lake Sammamish, the City of Bellevue has more than 60 miles of streams,
MOFARNO 160EC MATERIAL SAFETY DATA SHEET. SECTION 1 Chemical product and Company identification
MOFARNO 160EC MATERIAL SAFETY DATA SHEET Product Name: Mofarno 160EC Active Ingredients: Fomesafen + Quizalofop-p-ethyl Chemical name: SECTION 1 Chemical product and Company identification Fomesafen: 5-(2-chloro-a,a,a-trifluoro-p-tolyloxy)-N-methylsulfonyl-2-nitrobenzamide
DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP
DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP CONTENTS WHAT IS RISING DAMP STEP 1 SURVEY STEP 2 METER READINGS STEP 3 CONCLUSION STEP 4 PREPARATION FOR TREATMENT STEP 5 TYPE OF TREATMENT STEP 6
Florida Department of Environmental Protection
Florida Department of Environmental Protection Background Mobile vehicle and equipment washing involves washing at a location where vehicles are based (such as a trucking company, warehouse, bus station,
Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps
Foundations on Expansive Clay Soil Part 3 - Investigation of Failed Foundations Presented by: Eric Green, P.E. Structural Engineer Slide 1 Copyright Eric Green 2005 Investigation of Foundation Failure
SECTION 31 20 00 EARTH MOVING
SECTION 31 20 00 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section describes the requirements for excavating, filling, and grading for earthwork at Parking Structure, new exit stair and as required to
Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS
Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS Table of Contents Purpose... 2 Commencement... 2 Application... 2 Referral Agency... 2 Compliance with the QDC... 2 Associated
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements
Instruction Manual. Window Wiper AFW900. (Read carefully before use)
Instruction Manual Window Wiper AFW900 (Read carefully before use) When using electrical appliances, basic precautions should always be followed, including the fact READ ALL INSTRUCTIONS IN THIS MANUAL
PRODUCT SAFETY DATA SHEET According to 91/155 EC 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING
G.W.B.PRODUCT LTD, 276 YORK WAY, LONDON N79PH TEL:020 7619 1650 FAX:020 7609 9196 EMAIL:[email protected] www.gwbproducts.co.uk -1-1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY /
YEAR TRANSFERRABLE TANALISED 25 YEAR TERMITE RESISTANT* STRUCTURAL TIMBER AND WOOD PRODUCTS GUARANTEE
TRANSFERRABLE TANALISED 25 TERMITE RESISTANT* STRUCTURAL TIMBER AND WOOD PRODUCTS GUARANTEE Thank you for selecting Tanalised termite resistant* structural timber and wood products for your new home or
