Podium roof decks / parking roof decks. installation guide 0.4
|
|
|
- Ethelbert Roberts
- 10 years ago
- Views:
Transcription
1 Podium roof decks / parking roof decks design and installation guide 0.4
2 0 Introduction 1 Design considerations 1.1 standards CE-marking BS EN Load classification 1.3 roof constructions Cold roof construction Warm roof construction Inverted roof construction Roof construction without thermal insulation 1.4 thermal insulation 1.5 waterproofing systems Continuous waterproofing systems - Bitumen modified bitumen waterproofing membranes (APP SBS) - Synthetic waterproofing membranes - Liquid-applied roof waterproofing - Mastic asphalt - Water resistant concrete 1.6 details 1.7 design of falls structural roof deck 1.8 roof drainage Stormwater discharge via gravity drainage inside a building roof outlets Linear drainage channel Stormwater discharge over the roof edge Surface water from adjacent roofs and facades 2 the composition of a podium and parking roof deck 2.1 separation layer 2.2 slip layer 2.3 protection layer 2.4 drainage layer 2.5 filter layer 2.6 nd Drainage Systems ND Drainage Systems on inverted roof constructions Designing the drainage layer 2.7 sub-base layer Sub-base layer on a warm roof construction / roof construction without thermal insulation Sub-base layer on an inverted roof construction 2.8 Levelling layer 2.9 Laying course 2.10 Paving Falls Pavers and flags Laying patterns Joint filling Retaining edges 3 podium and / or parking roof decks combined with intensive green roofs 4 nophadrain podium deck and parking deck systems 4.1 podium Deck System load class 1 Warm roof construction / roof construction without thermal insulation a. Composition without sub-base layer b. Composition including sub-base layer c. Composition including levelling layer Inverted roof construction a. Composition without sub-base layer b. Composition including levelling layer 4.2 park Deck System-Cars load class 2 Warm roof construction / roof construction without thermal insulation a. Composition without sub-base layer b. Composition using larger concrete flags / slabs without sub-base layer c. Composition including sub-base layer Inverted roof construction a. Composition without sub-base layer b. Composition using large format concrete flags / slabs without sub-base layer c. Composition including sub-base layer 4.3 park Deck System-Trucks load class 3 Warm roof construction / roof construction without thermal insulation a. Composition using large format concrete flags / slabs without sub-base layer b. Composition including sub-base layer Inverted roof construction a. Composition using larger concrete flags / slabs without sub-base layer b. Composition including sub-base layer Appendix A - Index test: Assessment of the level of protection provided by the protection layer. appendix B - Performance test: Assessment of the performance and behaviour of a pavement structure under simulated trafficking conditions performed at the Technical University Munich.
3 0 Introduction As urbanisation expands and the number of cars on our streets continues to grow, the lack of parking places is forcing us to reconsider our use of space, to maximise its potential, and to investigate the possibility of vertical development. Modern offices, apartment blocks and shopping centres use a combination of hard and soft landscaping on their flat roofs and underground parking facilities to make the most of their limited open space. Careful planning and good design will improve overall living conditions within our cities by creating large, open green areas and places for recreation and leisure, while sub-surface structures provide the necessary underground parking that will prevent it from intruding into the urban environment. Careful planning by architects and design engineers can maximise the use of valuable open spaces by covering roofs with extensive and/or intensive planting schemes that are combined with suitable hard-landscaping to provide access for vehicles and/ or pedestrians. Any design will need to accommodate specific construction requirements such as the required composition depth for elemental paving, the depth of growing medium required by the planting scheme, the maximum permissible surface loads, the provision of a suitable waterproofing system, and so on. When paving of any type is used, it will not be constructed over a prepared sub-grade, as would normally be the case, but will be constructed on top of a structural deck, and so the design must address the following considerations: the difference in behaviour and reaction that can be expected between natural sub-grades and constructed roof decks the waterproofing system must be suitable for both static and the loadings the type of roof construction, whether it is a warm roof, an inverted roof, or a cold roof the compressive strength of any thermal insulation the type and depth of any granular materials, such as sub-base layers or laying courses the type, depth and behaviour of any elemental paving the anticipated usage and the predicted intensity of use of the roof deck structure by both people and vehicles, and the loads imposed as a consequence of such use 1 design considerations 1.1 Standards CE-marking BS EN The European standard BS EN Geotextiles and geotextilerelated products. Characteristics required for use in drainage systems specifies the relevant characteristics of geotextiles and geotextile-related products used in drainage systems, and the appropriate test methods to determine these characteristics. This standard provides procedures for the evaluation of conformity of the product to this European Standard and for factory production control procedures. Based upon this European standard, geotextiles and geotextile-related products used in drainage systems must carry a CE-mark. Drainage systems are defined as systems that collect and transport precipitation, ground water, and / or other fluids. It is not only geotextiles such as woven and non-woven filter fabrics that fall within the scope of this European Standard (BS EN ISO Geosynthetics Terms and definitions ), it also includes geotextile-related products e.g. prefabricated sheet drains (geocomposites) and eggbox-shaped dimpled sheets (geospacers*). As a responsible manufacturer, Nophadrain BV is required to prepare a declaration of conformity that the geotextiles and geotextile-related products placed onto the market fulfil the requirements as set forth in BS EN Part of this declaration of conformity is a statement of factory production control procedure. This procedure consists of a permanent internal production control system to ensure that the ND Drainage Systems comply with BS EN and that the measured values conform to the declared values. Nophadrain is audited annually by a notified body (an independently accredited body). The declaration of conformity entitles Nophadrain to affix the CE-marking to its Drainage Systems and to place its products onto the European market. All geotextiles and geotextile-related products placed in the market by Nophadrain have the CE-marking affixed. * three-dimensional polymeric structure designed to create an air space in soil and / or other materials in geotechnical and civil engineering applications (BS EN ISO 10318) 1.2 Load classification There are no published standards governing the construction of elemental pavements over a roof deck in the UK or RoI. Through research in close cooperation with the Technical University in Munich, Germany, the following load classes can be distinguished based up on the intended use of the roof deck. Load class Use Traffic Axle load up to Wheel load up to 1 Intensive green roofs, podium roof decks, patio roof deck Pedestrian, bicycles 2 Parking roof deck Cars 10 kn Front axle 15 kn Rear axle 5 kn Front axle 7.5 kn Rear axle 3 Parking roof deck Heavy goods vehicles (HGV) 100 kn 50 kn Table 1. Load classification Nophadrain Podium Roof Decks Parking Roof Decks
4 1.3 Roof deck constructions The structural deck needs to be able to withstand and to absorb the static and dynamic loads imposed during construction and final use. The following roof deck constructions are recognised: Cold roof construction This is a roof construction with an independent ceiling enclosing an air space between the structural deck and the ceiling. When insulation is used it should be placed below the structural deck with a ventilated airspace in between. Generally speaking, this type of roof deck construction is not suitable for vehicular trafficked decks; i.e. load classes 2 and 3. Warm roof construction This is a roof construction without a ventilated airspace beneath the structural deck. When insulation is used it should be placed on top of the structural deck. In general, this type of roof deck construction is suitable for both pedestrian and vehicular trafficked roof decks; i.e. load classes 1 to 3. Inverted roof construction Insulation is placed on top of the waterproofing membrane. Should an inverted roof be selected for paving, moisture diffusion measures should be considered. When a paving is installed, a damp-permeable drainage layer must be placed over the thermal insulation in order to protect the insulation from accumulating moisture (internal condensation) over time. In general, this type of roof deck construction is suitable for both pedestrian and vehicular trafficked roof decks; i.e. load classes 1 to 3. Roof construction without thermal insulation On top of the structural deck the waterproofing membrane is installed without any thermal insulation. A characteristic of this roof construction is that the space beneath the roof is not heated. In general, this type of roof deck construction is suitable for both pedestrian and vehicular trafficked roof decks; i.e. load classes 1 to Thermal insulation Thermal insulation needs to be CE-marked based upon the BS EN Thermal insulation products for buildings. Factory made Specification. There are two different methods for installing thermal insulation to a roof deck: WRC = insulation is placed beneath the waterproofing membrane warm roof construction IRC = insulation placed above the waterproofing membrane inverted roof construction A cold roof has been omitted as this type of roof construction is rarely used nowadays. The waterproofing membrane and the applied thermal insulation should be able to withstand short and long term loadings. Should any deformations of the thermal insulation be expected, it should be taken into account when detailing the waterproofing membrane (roof outlet, roof edge, roof protrusion, etc.). For load class 1, the roofs built on an insulated roof, the thermal insulation should meet minimum load class dh. For load classes 2 and 3 the thermal insulation should meet load class ds respectively load class dx. The suitability of thermal insulation is to be demonstrated by the manufacturer. Suitability of the various types of thermal insulation: Thermal insulation classification Roof construction dm dh ds dx Expanded polystyrene (EPS)* in accordance with BS EN Thermal insulation products for buildings. Factory made products of expanded polystyrene. Specification Extruded polystyrene( XPS)* in accordance with BS EN Thermal insulation products for buildings. Factory made products of extruded polystyrene. Specification Rigid polyurethane foam (PUR)* in accordance with BS EN Thermal insulation products for buildings. Factory made products of rigid polyurethane foam. Specification Cellular glass (CG)* in accordance with BS EN Thermal insulation products for buildings. Factory made products of cellular glass. Specification WRC 100 kpa* 150 kpa* IRC WRC 200 kpa* 300 kpa* 500 kpa* IRC 300 kpa* 300 kpa* 500 kpa* 700 kpa* WRC 100 kpa* 100 kpa* 150 kpa* IRC WRC 400 kpa* 400 kpa* 900 kpa* 1,200 kpa* IRC Table 3. Load class and compressive strength thermal insulation * compressive strength at 10 % deformation in accordance with BS EN 826 Thermal insulating products for building applications. Determination of compression behaviour
5 Load classification Description Possible application dm dh ds dx Medium load bearing High load bearing Very high load bearing Extreme load bearing Table 2. Load classification thermal insulation Extensive green roof Intensive green roof/podium roof deck Parking deck with limited car traffic Parking deck with car and truck traffic Recommendation If a paving needs to composition over an insulated roof, it is recommended that an inverted roof construction with XPS insulation or a warm roof construction with cellular glass be chosen. With an inverted roof the waterproofing membrane should be fully bonded with the structural deck, in order that any leak in the waterproofing membrane can be easily located. The XPS insulation panels offer extra protection of the waterproofing membrane during installation of the paving composition. It is important that a damp-permeable drainage layer is placed on top of the XPS insulation. This allows the panels to dry. Water absorption due to internal condensation will be minimised. It is not necessary to install a separate vapour control layer as the waterproofing itself acts as one. The drainage layer should not damage the top of the insulation panels. Full bonding of the waterproofing membrane is also possible with a warm roof construction if cellular glass is used as thermal insulation. The cellular glass panels are fully bonded with the structural deck and all joints are filled with bitumen. The waterproofing system is thereby fully bonded with the cellular glass panels. 1.5 Waterproofing systems Continuous waterproofing systems Roof constructions are, in general, protected against the penetration of water by a waterproofing system (bitumen, synthetic or liquid-applied). When designing and choosing a waterproofing system, the intended use, applicable standards, regulations and standards of good practice have to be observed. Roof decks should be constructed with adequate falls. The waterproofing system should be designed to suit the anticipated use. To maintain the integrity of the waterproofing membrane, and to ensure proper construction of the paving, it is essential that the membrane system be laid as flat as possible. On trafficked roof decks, horizontal loads caused by vehicle overrun can excessively compress the waterproofing membrane. Such loading should be avoided and therefore separation and slip layers should be built in to the structure. The waterproofing membrane beneath any vegetation (intensive or extensive planting schemes) should be root resistant or protected against root penetration by a separate root barrier. Root resistance can be proven if the material has passed the FLL-root resistance test. The membranes can be applied in one or two layers and attached to the structural deck according to the following methods: loose laid and ballasted mechanically fixed fully bonded The composition of a fully bonded waterproofing system can be as follows: Bitumen modified bitumen waterproofing membranes (APP SBS) at least two layers first layer: a polyester based roofing felt fully bonded to the structural deck (pour and roll) top layer: a root resistant APP or SBS waterproofing membrane fully bonded (torched) Synthetic waterproofing membranes at least two layers first layer: a polyester based roofing felt fully bonded to the structural deck (pour and roll method) top layer: a EPDM, ECB, POCB or TPO waterproofing membrane fully bonded to the first layer Liquid-applied roof waterproofing liquid-applied roof waterproofing is regarded as a single layer system it should adhere to the entire surface and be applied in at least two discrete layers a suitable geotextile should be placed in between the layers as a reinforcement the manufacturer should have European Technical Approval in accordance with ETAG 005 Liquid Applied Roof Waterproofing Kits Mastic asphalt the concrete sub-structure needs to be primed before installation as a sub-layer a root resistant APP SBS torch-on membrane; the asphalt layer with a minimum thickness of 25mm should be installed on top of the sub-base Water-resistant concrete requirements for water-resistant concrete are specified in BS EN Concrete. Specification, performance, production and conformity and BS 8500 Concrete Complementary British Standard to BS EN Parts 1 and 2 cracks in any direction should be limited to 0.2mm Recommendation It is recommended that a waterproofing membrane is fully bonded with the structural deck. In many installations leakages occur due to incorrect detailing, poor choice of materials or errors / damage incurred during installation. When a loose laid waterproofing system is damaged, the point of leakage is difficult to locate as the water can move freely over the structural deck. Fully bonded waterproofing systems give much more security if they are installed on a closed structural deck. This means that with insulated roof constructions the choice is limited to a warm roof with cellular glass or an inverted roof with XPS insulation. If it has been decided to install a warm roof construction in which the waterproofing membrane is not fully bonded with the structural deck, it is recommended that separate compartments within the vapour control layer be created. In case of any damage to the waterproofing membrane, any leak can be located more easily. Nophadrain Podium Roof Decks Parking Roof Decks
6 1.6 Details Basically, the same waterproofing detail principles apply to hard landscaped roof decks as to flat roof decks. The waterproofing membrane should be brought up above the surface level (paving) by at least 150 mm. 150mm At door thresholds where a drainage channel is installed, the waterproofing membrane can be brought up above the surface of the paving by 50 mm. If the waterproofing membrane projects over the roof edge into the ground, it is recommended that the waterproofing membrane extends a minimum 500 mm beyond the edge and at least 200 mm over a joint. When paving is placed against the façade, a rubber strip is placed between the paving and the waterproofing membrane to protect the waterproofing membrane against mechanical damage. 150mm 50mm Detail 1. Door threshold Detail 2. Facade 1.7 Design of falls - structural roof deck The structural deck of a trafficked roof deck should be constructed with adequate falls to prevent water ponding on the waterproofing membrane, the sub-base, and/or the laying course. Falls should be such that surface water is directed off and away from the structural deck as quickly as possible. In order to achieve satisfactory drainage, trafficked roof decks should have a fall of not less than 1 in 80 (~1.3%). However, because of the risk of settlement, roof deflection and construction inaccuracies, a fall greater than 1 in 80 should always be stipulated. It is both practical and economic to design using falls of 1 in 40. However, on some buildings this can prove to be an excessively severe design criterion. As an alternative, the designer may elect to use a fall of 1 in 80, and then add a further 25mm of fall for concrete roof decks or an additional 15mm of fall for metal roof decks. Recommended falls of a structural deck: load class 1 1 in 50 load classes 2 and 3 1 in 40 Falls beneath the water proofing membrane can be achieved: in the structural deck by screed to falls by tapered thermal insulation Note If water is ponding on the structural deck due to a lack of sufficient falls additional measures need to be taken in respect of the drainage and possible frost damage of the paving composition. Possible solutions are: the use of a geo-composite suitable for a roof with no fall with a specification of the drainage length the use of a no fines sub-base material (material with no part cles smaller than 1mm) the use of a no fines laying course material when the paving is placed directly on top of the ND Drainage Systems the use of a no-fines permeable concrete The most suitable solution depends on the individual project. Products: ND 800 Drainage System
7 1.8 Roof drainage On roof decks carrying an elemental pavement, drainage of surface water and seepage water is achieved by means of roof outlets. The roof outlets are connected to a gravity drainage system within or outside the building that directs collected water to a conventional sub-surface stormwater system or over the edge of the roof deck. All surface and seepage water should be discharged at standard atmospheric pressure and without any attenuation. Three discharge levels are identified: 1st level waterproofing membrane 2nd level elemental paving 3rd level thermal insulation (inverted roof) Stormwater discharge via gravity drainage inside a building roof outlets Roof outlets have to be placed at the lowest point of the roof. They have to be dimensioned in accordance with BS EN Gravity Drainage Systems Inside Buildings and be accessible for inspection at all times. The roof outlets must collect and discharge both the surface water run-off from the paving along with any water that penetrates the paving joints and enters the laying course. Roof outlets located within a paved area should incorporate an inspection chamber with a gully top grating laid flush with the paving. The class of the inspection chamber and the gully top grating should match or exceed the load class of the overall roof deck. The inspection chamber should also incorporate a silt trap. Point loads on the inspection chamber should be dispersed over the sub-base or drainage layer. The shaft of the inspection chamber should enable collection and discharge of water from the 1st discharge level (waterproofing membrane) and the 3rd discharge level (thermal insulation inverted roof). The gully top grating should be able to collect the water from the 2nd (elemental paving) discharge level. Linear drainage channel The laying course or support layer for a linear drainage channel must not obstruct or block the horizontal flow of the drainage layer. Linear drainage channels may be used as an alternative to inspection chambers with a gully top grating. The gratings of the linear drainage channel units should permit collection and discharge of the surface water without the need for any additional pressure or attenuation. Both drainage channel and grating must match or exceed the load class of the roof deck BS EN 1433 Drainage channels for vehicular and pedestrian areas Classification, design and testing requirements, marking and evaluation of conformity and BS EN 124. The linear drainage channels should be connected through appropriate inspection chambers to roof outlets and when placed in front of façades/door thresholds can discharge through the drainage layer. Stormwater discharge over the roof edge Surface water can also be collected by a roof-edge gutter system, or discharged over the roof edge into the adjacent ground. A filter or fin drain construction (trench of clean, free-draining, inert aggregate surrounding a perforated pipe that is wrapped in a geotextile) must be placed along the edge to prevent inundation and damage to the sub-base of the paved area. Where vertical walls are present, such as in a basement structure, they must be protected with a suitable Drainage Systems that will prevent any composition of hydrostatic pressure against the sub structure. The requirements of the gully top grating depend on the load class (BS EN 124 Gully tops and manhole tops for vehicular and pedestrian areas ): load class 1 = gully top grating class A load class 2 = gully top grating class B load class 3 = gully top grating class D Detail 4. Stormwater discharge over the roof edge Detail 3. Inspection chamber with gully top grating Surface water from adjacent roofs and facades When determining the surface water discharge requirement of a roof deck, it is essential that any potential discharges from adjacent roofs and façades are accommodated. If such accommodation is not possible, adequate provision for independent drainage of these adjacent roofs must be made. Run-off from adjacent facades can be collected and discharged using aggregate strips and/or linear drainage channels connected to appropriate roof outlets or the drainage layer. Nophadrain Podium Roof Decks Parking Roof Decks
8 2 the composition of a podium and parking roof deck The composition of elemental paving comprises the layers listed below, each of which is considered in subsequent sections: separation layer slip layer protection layer drainage layer filter layer sub-base layer levelling layer laying course paving The compatibility and co-operation of each of the individual layers is critical to determining a reasonable life-span for a flexibly paved surface. Each layer must have the ability to absorb and constrain the potential dynamic and static loadings, have adequate compressive strength, and must not exhibit any unacceptable short-term flexion. Normally each layer has its individual function in the total system composition. However it is possible that: a single product integrates the function of several layers e.g. the slip layer can also fulfil the function of the separation and protection layer certain layers use more than one product e.g. the slip layer needs to have two separate non-adhesive surfaces to enable slippage to occur 2.1 Separation layer Chemically incompatible building materials need to be isolated by a separation layer (e.g. Polyvinyl Chloride [PVC] and Polystyrene [PS]). A separation layer can consist of a: plastic sheet geotextile Incompatible building materials need to be separated (covered) completely. The ND Drainage Systems can be provided with a factoryinstalled separation and slip film, or a moisture diffusion open geotextile on the back. Products: ND Drainage Systems ND TGF-20 Separation and Slip Film ND TSF-100 Slip and Protection Sheet 2.2 Slip layer During construction, and when in use, flexible pavements impose both vertical and horizontal loads. Horizontal loads are generated by temperature changes within the structure and from external dynamic sources such as braking, acceleration, and turning of vehicles. These vertical and horizontal loads must be borne by the underlying layers. However, it should be noted that waterproofing materials / systems are not capable of withstanding the horizontal loads typical of a flexible pavement and therefore care must be exercised when specifying. Where there is concern regarding the horizontal load-bearing capacity of the waterproofing membrane, a slip layer, comprising two, smooth, non-sticky surfaces that can move with respect to each other, will be required. In general plastic sheets manufactured from the following materials are used as a slip layer: PET (Polyethylene terephthalate) PP (Polypropylene) PE (Polyethylene) PS (Polystyrene) In the Nophadrain Podium Deck System, this slip function is achieved using the ND TGF-20 Separation and Slip Film which is placed underneath the ND Drainage Systems fitted with a separation and slip film. In this particular Nophadrain system, the essential separation and protection layer is formed by the ND Drainage Systems which is also the second smooth surface of the slip layer. In the Nophadrain Parking Deck System - cars / heavy goods vehicles (load classes 2 and 3), a ND TSF-100 Slip and Protection Sheet forms one surface while the protection and slip film of the ND Drainage Systems forms its counterpart. The ND TSF-100 Slip and Protection Sheet also fulfils the function of the protection layer in the Nophadrain Parking Deck System - cars / heavy goods vehicles. On an inverted roof construction, the slip layer consists of two layers of the ND TGF-20 Slip Sheet installed underneath the thermal insulation. Products: ND Drainage Systems ND TGF-20 Separation and Slip Film ND TGF-100 Slip and Protection Sheet 2.3 Protection layer The protection layer guards the waterproofing membrane against any damage caused by static and dynamic loads and simultaneously isolates materials that are chemically incompatible. When this layer has a smooth, non-sticky surface it can form part of the slip layer. At heavier loadings (load classes 2 and 3), and when a sub-base layer (load class 1) is installed, heavy
9 geotextiles, plastic sheets, concrete layers, and the like are needed to guard the waterproofing membrane against damage from static and dynamic loads occurring during installation and when in use. For lightweight static and dynamic loads (load class 1) the ND Drainage Systems can act as a protection layer when fitted immediately after installation of the waterproofing layer, the root barrier, or the separation and slip film. On roofs of load class 1 (podium roof decks), and load classes 2 and 3 (trafficked roof decks) where a levelling layer or sub-base is installed, or when wheel loaders are being used during installation, it is recommended that a ND TSF-100 Slip and Protection Sheet be installed above the waterproofing system. The ND TSF-100 Slip and Protection Sheet should be installed in such a way that no granular material can get underneath and damage the waterproofing membrane. The protection layer can also fulfil the function of the separation and slip layer. Loose-laid separation and protection layers must overlap by at least 100 mm, and the layer may not creep by more than 5 % with a maximum of 2 mm. An assessment of the level of protection provided by the protection layer on trafficked decks (load classes 1 to 3) can be made through index tests (see appendix A) of the individual products or through a performance test (see appendix B) of the complete composition. Index test ND TSF-100 Slip and Protection Sheet (Load classes 1 to 3) see appendix A, table 11. The ND TSF-100 Slip and Protection Sheet can be used on top of an insulating layer or a waterproofing membrane with a greater a long-term tolerable elongation in %. The long-term elongation of the insulation or the waterproofing has to be demonstrated by manufacturer. Performance tests Nophadrain Park Deck System - cars / heavy goods vehicles (load classes 2 and 3) see also appendix B. Performance test data for the various composition options for load classes 2 and 3 are available on request. Products: ND Drainage Systems ND TSF-100 Slip and Protection Sheet 2.4 Drainage layer The drainage layer relieves hydrostatic pressure from the waterproofing membrane. It discharges excess water underneath the sub-base layer/laying course and prevents the ponding of water in these layers and the risk of frost heave affecting the paving. The drainage layer must have good vertical permeability combined with the ability to transport surface water horizontally away from the roof area to the roof outlets or over the roof edge. Retention of water in the sub-base layer and/or laying course is to be avoided at all times. The drainage layer must maintain full functionality for a period of 50 years, in compliance with DIN 4095 Drainage and protection of sub-structures design, dimensioning and installation. The drainage capacity should be specified in litres per second per linear metre l/(s.m) taking into account the roof gradient and the expected load pressure. See Nophadrain brochure: Designing the drainage layer Any Drainage Systems, including eggbox-shaped dimpled plastic sheets (geospacers), that forms part of a drainage system, must be CE-marked according to BS EN The drainage capacity of the ND Drainage Systems (max. flow length) increases in line with the amount of stormwater discharged over the surfacing. 2.5 Filter layer The filter layer guards the drainage layer against clogging by fine particles carried down from the sub-base layer or laying course, and so ensures effective horizontal drainage. The pore size of the woven and non-woven geotextiles should be matched to the grain size and grading envelope of the granular materials used for the sub-base layer and laying course. When topsoil is being used, special measures should be taken to prevent soil fines clogging the filter layer e.g. by installing ND WSM-50 Water Reservoir Panels. Woven and non-woven filter fabrics (geotextiles) must be CE-marked according to BS EN when placed on top of a geospacer. Note Both woven and non-woven filter fabrics must overlap by least 100mm, and at the edges the filter fabrics should be brought up to the surface of the paving in order to prevent washing-out of the granular materials. The filter layer should be covered within one week of installation and should be protected against wind scour. The filter layer, whether it is a non-woven or woven geotextile, forms part of the ND Drainage Systems. The geotextile is bonded to each dimple of the plastic sheet and overlaps the core by 100 mm. Load class* Sub-base layer Puncture resistance BS EN ISO in kn 1 without with and 3 with / without 2.5 Table 4. Filter layer * see table 1. Load classification Nophadrain Podium Roof Decks Parking Roof Decks
10 2.6 ND Drainage Systems ND Drainage Systems comprise the filter layer, the drainage layer, and the separation and protection layer as one integrated unit. The core of the ND Drainage Systems is a 13 mm - 27 mm thick dimpled plastic sheet with a filter fabric (woven or non-woven) bonded to each dimple. Depending on the application, the core may be perforated and provided with a pressure dividing slip film, or a moisture diffusion open geotextile on the back. ND Drainage Systems comprise the filter layer, the drainage layer, and the separation and protection layer as one integrated unit. The core of the ND Drainage Systems is a 13 mm - 27 mm thick dimpled plastic sheet with a filter fabric (woven or non-woven) bonded to each dimple. Depending on the application, the core may be perforated and provided with a pressure dividing slip film, or a moisture diffusion open geotextile on the back. ND Drainage Systems on inverted roof constructions Certain ND Drainage Systems have a perforated core. These Drainage Systems prevent the formation of a vapour control layer on top of the XPS thermal insulation. The top of the XPS insulation panels can dry out and therefore Drainage Systems Load Roof construction class* With insulation Without insulation Water resistant concrete Inverted roof ND ND ND 200s 1 ND 200sv 1 ND ND / 2** * ND 600s 1 ND 600sv 1 / 2 ND / 2 ND 600hdsv 2 / 3 ND 620hd 2 / 3 Table 5. Applications ND Drainage Systems * see table 1. Load classification ** only load class 2 on a roof construction of water resistant concrete..20 = with pressure dividing slip film s = perforated core (moisture diffusion open) v = moisture diffusion open geotextile hd = high compressive strength (> 1,100kN/m 2 ) Designing the drainage layer On those roofs with a hard landscaping composition, storm/surface water is partly drained over the surfacing (q o ), referred to as the 2 nd discharge level. The drainage layer or the 1 st discharge level has to q a,s = r - q o Br intercept the stormwater that has penetrated the surfacing (q a.s ). q a.s = stormwater penetrating the surfacing l/(s.m 2 ) (table 6) r = rainfall intensity l/(s.m 2 ) in accordance with BS EN qo = stormwater discharged over the surfacing l/(s.m 2 ) Lr Based upon a 15 minute rainfall intensity happening once every 10 years of r (15) (0,1) = 0.03l/(s.m 2 ) the following values can be used to determine the amount of stormwater penetrating the surfacing (q a.s ): Surface q a,s (l/(s.m 2 ) Concrete block pavers 0.01 Self-binding gravel Turf paving on water permeable sub-base 0.03 Table 6. Stormwater penetrating the surfacing q a.s Figure 1. Effective roof area m 2 Lr = length of the roof to be drained m Br = the plan width of roof from gutter to ridge m
11 The amount of water that needs to be collected and discharged by the drainage layer (q ) can be calculated in units of per l/(s.m) using the following equation: q = quantity of water to be discharged by the drainage layer l/(s.m) q a.s = stormwater penetrating the surfacing l/(s.m 2 ) (table 6) A = effective roof area m 2 (Lr x Br) q a,s x A q = in l/(s.m) Lr 2.7 Sub-base layer The function of the sub-base layer is to absorb and spread any static and dynamic loads and so prevent deformation of the elemental paving. To ensure proper functioning of the sub-base layer, a stable Drainage Systems should be installed as a drainage layer. By proper dimensioning of the sub-base layer, the loading of the layers beneath it is reduced. The depth of the sub-base layer should be designed to suit the expected static and dynamic loading and the strength of the layers beneath it. A sub-base layer can be installed to spread the static and dynamic load (load classes 2 and 3) and/or to create falls (load classes 1 to 3). Depending on the anticipated load class, the sub-base layer needs to be compacted to meet the following deformation modules: Sub-base layer on an inverted roof construction In the design of an inverted roof construction, moisture diffusion measures should be observed at all times. The installation of a vapour control layer on top of the thermal insulation is not permitted. As compaction of non-hydraulically bonded no-fines sub-base material (i.e.: a material with no particles smaller than 1mm) is difficult, the depth of the sub-base layer should be increased accordingly. For each individual object it must be determined whether the moisture diffusion of the ND Drainage Systems Type SV, is compatible with the installation of a no-fines sub-base layer. Load class* Static deformation modules E V2 in MN/m Load class* 1 Material Crushed natural material Granular size in mm Layer depth in mm Table 7. Deformation modules * see table 1. Load classification To check compaction is complete and correct, static or dynamic plate load tests should be undertaken. The most suitable type of vibrating plate compactor needs to be agreed with the design engineer. Sub-base layer on a warm roof construction / roof construction without thermal insulation The sub-base material should consist of crushed natural material with a granular size of 0-22 mm, 0-32 mm or 0-45 mm. In order to prevent damage to the roof outlets, only a limited amount of calcium hydrate may be leached from the sub-base material. This requirement can be relaxed in those cases where the collection and discharge of stormwater does not take place by roof outlets but is directed over the roof edge. 2 3 Hydraulically bound crushed material Crushed natural material Crushed natural material Hydraulically bound crushed material Crushed natural material Table 9. Sub-base layer inverted roof construction * see table 1. Load classification ** suitability to be demonstrated by the manufacturer of the thermal insulation 0-32** ** / 0-45** Load class* Material Granular size in mm Layer depth in mm Crushed natural material Crushed natural material Crushed natural material / Table 8. Sub-base layer warm roof construction * see table 1. Load classification Nophadrain Podium Roof Decks Parking Roof Decks
12 2.8 Levelling layer In order to overcome height differences and / or to create falls, it may be necessary to install a levelling layer beneath pedestrianonly elemental pavements (load class 1) The levelling layer is a combination of the laying course and the sub-base layer. The paving is laid directly onto the levelling layer. Joint filling materials need to be carefully graded to suit both the actual joint width and the grading of the levelling layer material. This layer can consist of natural crushed material with a granular size of: 2-8 mm 3-9 mm The layer depth is a minimum of 50 mm and a maximum of 150 mm. Once the paving layer has been placed and cut-in as necessary, the whole composition is compacted. Where the levelling depth is greater than 150 mm, the levelling layer consists of crushed natural material with a granular size of 2-22 mm. The paving is laid on a separately installed laying course of crushed natural material with a granular size described above. 2.9 Laying course The laying course is required to accommodate variation in thickness of the paving units and to even out irregularity in the sub-base layer, as well as providing stability to the paving units. The laying course should be as shallow as possible; however, when the loads are reduced the depth of the laying course can increase slightly, because the risk of deformation is reduced. The bedding material used can consist of crushed natural material with a granular size of: 0-4 mm 0-5 mm 0-11 mm* 1-3 mm 2-5 mm On an inverted roof construction it might be necessary to use bedding material that is classed as moisture diffusion open or no-fines i.e. no particles smaller than 1 mm granular size. Jointing materials need to be carefully graded to suit the grading of the bedding material. Granular sizes of bedding materials that can be used for a moisture diffusion composition: 1-3 mm 2-5 mm The depth of the laying course following compaction should be mm. When paving blocks are installed with a thickness of 120 mm the laying course should be 40 mm with a granular size bedding material of 0 / 11 mm. Depending on the expected load and the type of paving to be used, the bedding material can be installed directly on top of ND Drainage Systems. * paving blocks thickness 120 mm depth laying course 40 mm 2.10 Paving For roof decks, some form of elemental paving (e.g.: block paving, small element paving) laid onto a flexible or granular laying course is normally used in preference to a rigid or semi-rigid paving (e.g.: concrete, macadam or asphalt). The main reasons for this choice of paving are: ease of access to the roof structure and the waterproofing system for inspection and maintenance the ability to continue and / or extend the use of adjacent hard or soft landscaping schemes over the surface of the deck, rendering it invisible to users protection of the waterproofing system against excessive static or dynamic loads low installation and maintenance cost A flexible pavement is permeable and consists of individual prefabricated elements. A flexible pavement is also referred to as an open pavement in comparison to a closed pavement such as concrete or asphalt. The thickness of the paving is based up on the load class, the paving units, the laying pattern and the bearing capacity of the layers beneath. There are more than 200 different types of paving units on the market. Falls As far as possible, stormwater should run across the surface of the paving and be collected by a suitable drainage system. Penetration of the paving, laying course and sub-base layers by surface / stormwater must be minimised by ensuring the paving is laid to adequate falls with relatively tight joints. Depending on the type of paving the following minimum falls need to be observed: concrete flags and natural stone flags 1: 50 concrete pavers and clay pavers 1: 40 natural stone paving 1: 33 open permeable paving (turf paving) 1:100 hydraulically bonded paving 1: 50 Falls can be created in: the structural roof deck the sub-base layer the levelling layer
13 In elemental pavements (ICBPs, clay pavers, etc.) it is possible for as much as % of the surface water to penetrate the joints and find its way to the underlying layers. Infiltration can be even higher in newly constructed pavements where the jointing has not had the opportunity to settle and self-seal with detritus, or on pavements with inadequate falls. Pavers and flags The paving units can be prefabricated pavers e.g. small element pavers, clay pavers, concrete block pavers, concrete flags, setts, or large format slabs. The width and depth of the joint, along with the material used to fill the joint, will determine whether surface water can be directed to the sub-surface layers. Small element pavers due to the small size and the inevitably generous size tolerances that occur with all natural paving units these pavers can only be used for load class 1 pavements Clay pavers clay pavers can be used for load class 1 pavements; the pavers can be installed without a separate sub-base layer onto a levelling layer or laying course directly on top of the ND Drainage Systems. The pavers should have a minimum thickness of 40 mm. Concrete pavers concrete pavers are used for load class 1 and 2 pavements. On vehicular-trafficked decks (load class 2) the concrete pavers are laid in 90 º and 45 º herringbone pattern. These patterns have the highest level of stability over the long term the pavers can be installed without a separate sub-base layer onto a levelling layer or laying course directly on top of the ND Drainage Systems. For load class 2 pavements the use of large format concrete flags / slabs is recommended at locations such as sharp curves, turning heads and entrance / exit ramps, because these have been shown to spread the imposed dynamic loads the pavers should have a minimum thickness of 40 mm for load class 1 pavements and a minimum of 80 mm for load class 2 pavements Concrete flags concrete flags can be used for load class 1 pavements the flags can be installed without a sub-base layer onto a levelling layer or laying course directly on top of the ND Drainage Systems the minimum thickness of the flags should be 40 mm Permeable paving permeable paving can be used on roof decks designed as load class 1 to 3 pavements due to its open structure this type of paving facilitates 100 % infiltration of surface water, therefore the load-bearing capacity is restricted for vehicular traffic it is recommended that permeable paving not be used for pavements in load class 2 or load class 3 that carry regular vehicular traffic Interlocking concrete block pavers interlocking concrete block pavers (ICBPs) can be used for load class 1 to 3 pavements. However they are mostly used for vehicular areas subjected to heavy loads (load class 2 and 3), where the forces generated by acceleration, braking (deceleration) and turning can be considerable ICBPs are also used for load class 2 pavements, where they may be laid onto a laying course that is placed directly over the ND Drainage Systems, that is, with no specific sub-base layer the minimum thickness of ICBPs should be for: - load class 1 min. 60 mm - load class 2 min. 80 mm - load class 3 min. 100 mm Large format concrete flags / slabs large format concrete slabs can be used for load class 1 to 3 pavements at locations such as sharp curves, turning heads and entrance / exit ramps, large format concrete flags / slabs are preferred as they are better able to bear and spread the imposed dynamic loads these larger concrete flags are also used on load class 2 and 3 vehicular-trafficked pavements where there is insufficient buildup depth to accommodate a separate sub-base layer. In such cases, the slabs can be laid onto a suitable laying course directly over the ND Drainage Systems the suitability of large format concrete flags / slabs for the appropriate load class is to be proven by the manufacturer Laying patterns Pedestrian areas can be laid to almost any laying pattern but those areas intended to carry vehicular traffic should use an interlocking pattern to maximise the lifespan of the pavement and to minimise maintenance. Load class 1 with / without sub-base layer 2 with sub-base layer 2 without sub-base layer 3 with sub-base layer Stretcher or running bond Basket weave 45 º Herringbone 90 º Herringbone Interlocking concrete block pavers Table 10. Laying patterns Nophadrain Podium Roof Decks Parking Roof Decks
14 90 º Herringbone 45 º Herringbone Stretcher or running bond Basket weave Figure 2. Examples of laying patterns Herringbone patterns and interlocking concrete block pavers give the greatest degree of interlock, as movement / creep is checked in both the transverse and longitudinal direction, and therefore these patterns and paving blocks have the highest level of stability over the long term. Joint filling Joint width is usually determined by Load Class and type of paving unit being laid. Jointing materials need to be carefully graded to suit both the actual joint width and the grading of the bedding material. When joint width is too tight, it can prevent proper filling of the joint and may allow adjacent paving units to be in direct contact, which can result in spalling or damage to the arisses (edges) of the units. Joints that are excessively wide may not be capable of generating the inter-unit friction that provides a significant proportion of the pavement s load-bearing capability. Granular sizes of joint filling materials: 0-4 mm 0-5 mm 0-8 mm 0-11 mm (joint width > 10 mm) Granular sizes of joint filling materials that can be used for a moisture diffusion composition: 1-3 mm 2-5 mm Proper joint filling is critical to the long-term performance and lifespan of pavements subject to vehicular traffic. Concrete pavings perform exceptionally well at distributing point loads to the underlying layers. This ability is dependent on the paving units being manufactured to keen dimensional tolerances that enables them to be accurately positioned and to have uniform joints widths. When these joints are properly filled, imposed loads, such as those created by vehicular traffic, generate a high level of frictional resistance (rotation resistance) between adjacent paving units and so the load is dispersed by partial transference to those adjacent units. To ensure full and proper filling of the joints, dry jointing sand should be scattered over the surface of the newly-laid pavement and swept into the joints with a brush, filling each joints as far as practical after consolidating the pavement using a vibrating plate compactor. The joints should be checked and topped-up as necessary following consolidation and will need to be checked again every few weeks for the first 3-4 months following completion, ensuring any partially-filled or hungry joints are topped-up with additional jointing material. After this initial period, the pavement should be checked three or four times a year as joints can be emptied by scour from wind and surface water, by the action of street cleaning machinery, and from day-to-day wear from traffic. Retaining edges Elemental pavements, such as those constructed from flexibly-laid concrete blocks pavers, must be properly restrained at the edges in order to prevent lateral slip and failure of the pavement as a whole. Properly constructed edge courses are vital to the performance, integrity and lifespan of any such pavement. The edge courses must lock in the body (or field) of the paving and so prevent any creep or looseness of the individual units. The most appropriate type of edge course is most often determined by the type of paving units and the planned use of the pavement; that is, whether it will be used for pedestrians only, or for both pedestrian and vehicular traffic. For vehicle standard pavements, the edge course units will require restraining in both the hori-zontal and vertical directions. This can best be achieved by laying the edge course units onto a bed of concrete and haunching with the same, so that the risk of creep or rotation is eliminated.
15 When concrete is used, however, there is a risk of calcium hydrate being leached and this could potentially cause damage to the roof deck drainage outlets. Consequently, for such applications it is recommended that the concrete is treated, or that a denser concrete (C20 / C25 standard) is used. Further, any concrete bed and haunch must not obstruct the horizontal drainage function of the pavement roof deck, and so must be placed on top of the filter and drainage layer. A possible alternative to the use of concrete bed and haunch is the ND Edge Retaining Profile. This product is eminently suitable for use with pavements of load class 1 and mm Products: ND 100/4V Edge Retaining Profile ND 150/4V Edge Retaining Profile ND 200/4V Edge Retaining Profile Detail 5. Edging with the ND Edge Retaining Profile 3 podium and / or parking roof decks combined with intensive green roofs By combining hard landscaping on a roof deck with soft landscaping features such as a lawn, perennials, shrubs, bushes and trees, the quality of life and the integration of the roofscape with the surrounding environment is considerably improved. The Nophadrain systems make these combinations easy to achieve by using water reservoir panels within the filter and drainage layer. The layer of growing medium is placed on top of these panels and planted-up with a suitable intensive planting scheme. The Nophadrain Design and installation manual Intensive green roofs, available on request, gives a detailed description and fuller guidance on this type of construction. Nophadrain Podium Roof Decks Parking Roof Decks
16 4 Podium deck and parking roof deck systems 4.1 Nophadrain Podium Deck System - load class 1 Warm roof construction / roof construction without thermal insulation a. Composition without sub-base layer Falls for paving are created by the roof construction Paving 40 mm thickness: e.g. clay pavers, concrete tiles, natural stone flags / slabs Laying course, depth mm: coarse sand or grit 1-3 mm or 2-5 mm 80 mm ND 220 Drainage System ND TGF-20 Separation and Slip Film b. Composition including sub-base layer Falls for paving created by roof construction and / or by grading of sub-base layer Paving 40 mm thickness: e.g. clay pavers, concrete tiles, natural stone flags / slabs 180 mm Laying course, depth mm: coarse sand or grit 1-3 mm or 2-5 mm Sub-base layer, depth 100 mm: crushed natural material 0-22 mm ND 620 Drainage System ND TGF-100 Slip and Protection Sheet
17 c. Composition including levelling layer Falls for paving created by roof construction and / or by grading of levelling layer Paving 40 mm thickness: e.g. clay pavers, concrete tiles, natural stone flags / slabs 100 mm Levelling layer, depth mm: crushed natural material 2-8 mm or 3-9 mm ND 220 Drainage System ND TGF-20 Slip Sheet Inverted roof construction a. Composition without sub-base layer Falls for paving are created by the roof construction Paving 40 mm thickness: e.g. clay pavers, concrete tiles, natural stone flags / slabs 80 mm Laying course depth, mm: grit 1-3 mm or 2-5 mm ND 200s Drainage System Thermal insulation* ND TGF-20 Separation and Slip Film ND TGF-20 Separation and Slip Film b. Composition including levelling layer Falls for paving created by roof construction and / or by grading of levelling layer Paving 40 mm thickness: e.g. clay pavers, concrete tiles, natural stone flags / slabs 100 mm Levelling layer, depth mm: crushed natural material 2-8 mm or 3-9 mm ND 200s Drainage System Thermal insulation* ND TGF-20 Separation and Slip Film ND TGF-20 Separation and Slip Film * suitability of thermal insulation to be demonstrated by manufacturer
18 4.2 Parking Deck System-Cars - load class 2 Warm roof construction / roof construction without thermal insulation a. Composition without sub-base layer Falls for paving are created by the roof construction Interlocking concrete paving blocks 80mm 140 mm Laying course, depth 30-50mm: grit 1-3 mm ND 620hd Drainage System ND TSF-100 Slip and Protection Sheet b. Composition using larger concrete flags / slabs without sub-base layer Falls for paving are created by the roof construction Large format concrete flags/slabs 70 mm (750 x 750 mm) * 150 mm Laying course, depth mm**: grit 2-5 mm ND 620 Drainage System ND TSF-100 Slip and Protection Sheet * suitability of large format concrete flags / slabs to be demonstrated by manufacturer ** layer depth in accordance with recommendations of the manufacturer of the concrete flags / slabs
19 c. Composition including sub-base layer Falls for paving created by the roof construction and/or by grading of sub-base layer Concrete pavers 80 mm: 90º or 45º herringbone pattern 270 mm Laying course, depth mm: grit 1-3 mm Sub-base layer, depth mm: crushed natural material 0-22 mm ND 620 Drainage System ND TSF-100 Slip and Protection Sheet Inverted roof construction a. Composition without sub-base layer Falls for paving are created by the roof construction Interlocking concrete paving blocks 80 mm 140 mm Laying course, depth mm: grit 1-3 mm ND 600hdsv Drainage System Thermal insulation* ND TGF-20 Separation and Slip Film ND TGF-20 Separation and Slip Film * suitability of thermal insulation to be demonstrated by manufacturer Nophadrain Podium Roof Decks Parking Roof Decks
20 b. Composition using large format concrete flags / slabs without sub-base layer Falls for paving are created by the roof construction 150 mm Large format concrete flags/slabs 110 mm (750 x 750 mm)* Laying course, depth mm**: grit 2-5 mm ND 600sv Drainage System Thermal insulation* ND TGF-20 Separation and Slip Film ND TGF-20 Separation and Slip Film c. Composition including sub-base layer Falls for paving created by roof construction and / or by grading of sub-base layer Concrete pavers 80 mm: 90º or 45º herringbone pattern 270 mm Laying course, depth mm: grit 1-3 mm Sub-base layer, depth mm: crushed natural material 0-22 mm ND 600sv Drainage System Thermal insulation* ND TGF-20 Separation and Slip Film ND TGF-20 Separation and Slip Film * suitability of paving flags / slabs to be demonstrated by manufacturer ** layer depth in accordance with recommendations of the manufacturer of the concrete flags / slabs *** suitability of thermal insulation to be demonstrated by manufacturer
21 4.3 Parking Deck System-Trucks - load class 3 Warm roof construction / roof construction without thermal insulation a. Composition using large format concrete flags / slabs without sub-base layer Falls for paving are created by the roof construction Large concrete flags / slabs 110 mm (750 x 750 mm)* 150 mm Laying course, depth mm**: grit 2-5 mm ND 620hd Drainage System ND TSF-100 Slip and Protection Sheet b. Composition including sub-base layer Falls for paving created by roof construction and / or by grading of sub-base layer Interlocking concrete paving blocks 100 mm 290 mm Laying course, depth mm: grit 1-3 mm Sub-base layer, depth mm: crushed natural material 0-32 mm ND 620hd Drainage System ND TSF-100 Slip and Protection Sheet * suitability of paving flags / slabs to be demonstrated by manufacturer ** layer depth in accordance with recommendations of the manufacturer of the concrete flags / slabs Nophadrain Podium Roof Decks Parking Roof Decks
22 Inverted roof construction a. Composition using larger concrete flags / slabs without sub-base layer Falls for paving are created by the roof construction 150 mm Large concrete flags / slabs 110 mm (750 x 750 mm)* Laying course, depth mm**: grit 2-5 mm ND 600hdsv Drainage System Thermal insulation* ND TGF-20 Separation and Slip Foil ND TGF-20 Separation and Slip Foil b. Composition including sub-base layer Falls for paving created by roof construction and / or by grading of sub-base layer Interlocking concrete paving blocks 100 mm Laying course, depth mm: grit 1-3 mm 290 mm Sub-base layer, depth 150 mm: crushed natural material 0-2 mm ND 600hdsv Drainage System Thermal insulation* ND TGF-20 Separation and Slip Foil ND TGF-20 Separation and Slip Foil * suitability of thermal insulation to be demonstrated by manufacturer ** layer depth in accordance with recommendations of the manufacturer of the concrete flags / slabs
23 Appendix A - Index test Assessment of the level of protection provided by the protection layer Determination of the efficiency of protection layers test sequence based on BS EN Geotextiles and geotextiles related products Determination of the long term protection efficiency of geotextiles in contact with geosynthetic barriers. Test procedure Inside a smooth-sided steel cylinder, a 20 mm thick rubber pad with a hardness of 50 shore A is placed beneath a 1.3 mm thick circular disc of lead over which is placed the test specimen (Nophadrain protection layer). A 200 mm deep layer of 20 mm diameter steel balls is then placed on top of the test specimen and the whole composition stressed 200,000 times at a frequency of 2.3 Hz in the servo-hydraulic test apparatus. Assessment On completion of the test cycle, the apparatus is dismantled and the six deformations displaying the greatest strain are recorded. From this data, the largest and smallest deformation readings are disregarded and the remaining values are averaged to determine a mean value for percentage deformation Using this test procedure, a sample is declared to have provided satisfactory protection when the calculated average elongation of the protection layer is less than the maximum tolerable long-term elongation of the waterproofing membrane. Applied dynamic stress The test is repeated three times, with each test run imposing the different applied stresses stated in table 11 below. These applied dynamic stresses are in accordance with the recommendations for the design and construction of trafficked roof decks of the Forschungsgesellschaft Landschaftsentwicklung Landschaftsbau e.v. (FLL). Figure 3. Servo hydraulic test apparatus 1. applied load 6. upper and lower steel plate 2. cylinder 7. load cell 3. geotextile separator 8. sand 4. steel balls (Ø 20 mm) 9. lead disc, d = 1.3 mm 5. test specimen - protection layer mm thick rubber pad Load Class Use Dynamic loading in kn Elongation in % Intensive green roofs, podium roof deck, patio roof deck Parking roof deck for cars with a max. gross mass of 2.5 tonne = 25 kn Parking roof deck for heavy good vehicles (HGV) with a max. gross mass of 16 tonne = 160 kn Table 11. Applied dynamic stress Nophadrain Podium Roof Decks Parking Roof Decks
24 Appendix B - Performance test Assessment of the performance and behaviour of a pavement structure under simulated trafficking conditions performed at the Technical University Munich Test procedure The test apparatus and component cross-section used for this test is shown diagrammatically in figure 4 below. The desired axle load is generated hydraulically via a fixed vertical cylinder. Adjustment of the tyre pressure at the given axle load simulates the type of loading generated by vehicular traffic. Lateral movement of the wheels equivalent to approximately 20 mm from true is generated during the test procedure by means of horizontally positioned hydraulic controls. The roll-over test procedure involves repeatedly moving the assembled test frame 900 mm backwards and then 900 mm forwards beneath the static axle at an average speed of 1 km per hour. Test frame and composition The road construction composition to be tested by the rollover procedure is prepared within the test frame (1,510 mm long x 1,410 mm wide). Strips of dense rubber are placed to the internal edges of the test frame to allow minor movement of the pavement construction and so simulate conditions expected on a much larger section of pavement. Assessment Deformation of the pavement is measured and recorded both during and on completion of the test procedure. During subsequent dismantling of the test frame and composition, each layer and component are closely examined for any evident deformation and consequent changes in characteristics Figure 4. Test apparatus performance test 1. vertical cylinder - desired axle load 2. horizontal cylinder - lateral movement 3. axle with tyres 4. test frame 5. road construction composition 6. rails to move test frame
25 Composition of an parking deck load class 2 combined with intensive planting scheme a b c d e f g h 1 Paving layer Concrete pavers 80 mm: 90 º or 45 º herringbone pattern a Vegetation layer Intensive planting scheme: lawn shrubs, bushes, trees 2 Laying course mm: coarse sand, grit 1-3 mm b Growing medium layer ND DGS-I Substrate Intensive / topsoil* 3 Sub-base layer 150 mm: crushed natural material 0-32 mm c Water reservoir layer ND WSM-50 Water Reservoir Panel 4 Filter layer d Filter layer 5 Drainage layer ND 620 Drainage System e Drainage layer ND 620 Drainage System 6 Slip layer f Slip layer 7 Separation and protection layer ND TSF-100 Slip and Protection Sheet g Separation and protection layer ND TSF-100 Slip and Protection Sheet 8 Root barrier layer Root resistant waterproofing membrane** h Root barrier layer Root resistant waterproofing membrane** * at depths greater than 500 mm (350 mm with topsoil), a pure, mineral-based substrate should be installed beneath the growing medium ** optional ND WSB-80 Root Barrier This information is published by Nophadrain BV as a contribution to good practice in the application of podium and parking utility roofs in the UK. Whilst every care has been taken in its preparation, Nophadrain excludes any liability for errors, omissions or otherwise arising from the contents of this brochure. The reader must satisfy himself or herself as to the principles and practices described in this brochure in relation to any particular application and take appropriate, independent, professional advice. Nophadrain EN Nophadrain Podium Roof Decks Parking Roof Decks
26 Nophadrain BV Visiting address Mercuriusstraat ER Kerkrade The Netherlands Postal address Postbus HA Kerkrade The Netherlands T +31(0) F +31(0) E [email protected] V
Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5
Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems
9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES Hunter Underground Systems 9.01 General 9.02 Surface water Drainage 9.03 Groundwater Drainage 9.04 Dispersal of Septic Tank Effluent 9.01 The use of
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H Soil Drainage Mat with Built-In Protection Layer POLYGUARD DRAINAGE MATS are three-part prefabricated geocomposite drain consisting of a
GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE
GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE Prof. J. N. Mandal Department of civil engineering, IIT Bombay, Powai, Mumbai 400076, India. Tel.022-25767328 email: [email protected] Module - 4
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
CHESTERFLEX ROOF WATERPROOFING MEMBRANES
CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED
AUSTRALIAN PAVING CENTRE
AUSTRALIAN PAVING CENTRE The Concept 02 The concept of Ecopave permeable paving is already well established in many countries where development threatens already over-stretched drainage and river systems.
Drainage Composites. The ready-made solution to sub soil drainage
Drainage Composites The ready-made solution to sub soil drainage The Ready-Made Solution to Sub Soil Drainage Drainage Composites are prefabricated subsurface-drainage products which directly replace conventional
Building Your Interlocking Concrete Pavement to Last a Lifetime
Building Your Interlocking Concrete Pavement to Last a Lifetime A Guide for Consumers Contents Building Your Interlocking Concrete Pavement to Last a Lifetime.... 3 What Does Installation Involve?....
rhuesker HUESKER HUESKER HUESKER HUESKER HUESKERr HUESKER HUESKER HUESKER HUESKERHUES Product- Portfolio HUESKER Engineering with Geosynthetics
HUESKER Engineering with Geosynthetics rhuesker HUESKER Product- HUESKER HUESKER HUESKER HUESKERr SKER HUESKER Portfolio HUESKER HUESKER HUESKER HUESKERHUES Engineering with Geosynthetics HUESKER Synthetic
The Most Advanced Name in Drainage Systems. Geotextile Products
The Most Advanced Name in Drainage Systems Geotextile Products ADS MEETs YOUR Geotextile NEEDS Advanced Drainage Systems, Inc. (ADS) single wall and N12 dual wall pipe have become the industry standard
Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane
Section Flat Roofs Warm deck single ply membrane Product: Rocksilk Krimpact Flat Roof Slab Fl01 Warm deck single ply membrane Product: Polyfoam ECO Roofboard Fl02 Warm deck built-up felt/ mastic asphalt
Division 2 Section 32 14 13.19 Section 02795
Note: The text must be edited to suit specific project requirements. It should be reviewed by a qualified civil or geotechnical engineer, or landscape architect familiar with the site conditions. Edit
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
SUSTAINABLE URBAN DRAINAGE SYSTEMS
overflow can lead into a permeable conveyance system to increase further the benefit and reduce the need for pipe systems. Pollutant removal rates have been shown to be high, with some pollutants being
SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)
SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795) Note: This guide specification for U.S. applications describes construction of permeable interlocking concrete
LANDSCAPING AQUA SPORT. Rainwater treatment using filter substrate channel. DIBt approval applied for
CIVILS LANDSCAPING AQUA SPORT Drainfix Clean Rainwater treatment using filter substrate channel DIBt approval applied for CIVILS LANDSCAPING AQUA SPORT Drainfix Clean Application areas For the treatment
Stabilenka HUESKER. and Separation. Engineering with Geosynthetics SKER HUESKER HUESKER HUESKER HUESKERHUES
HUESKER Engineering with Geosynthetics rhuesker HUESKER HUESKER HUESKER HUESKER HUESKERr rhuesker HUESKER Woven HUESKER HUESKER Fabrics HUESKER HUESKERr SKER HUESKER HUESKER HUESKER HUESKERHUES rhuesker
SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)
Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks
The full range of Kilsaran products are manufactured to fully meet all requirements of all current British and European Standards.
The extensive range of paving products available from Kilsaran will provide a full range of solutions for any project whether commercial, civic, industrial or a residential scheme. appraisal purposes Generally
Soils, Foundations & Moisture Control
Soils, Foundations & Moisture Control Soil The top loose layer mineral and/or organic material on the surface of the Earth that serves as a natural medium for the growth of plants and support for the foundations
Chapter 2 Basis of design and materials
Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural
synthetic waterproofing systems
GreeN roofing Waterproofing systems with SINTOFOIL TpO/Fpa membranes synthetic waterproofing systems Recently, green roofing systems have been attracting increasing interest because of the significant
Simplifying design and construction. Alan Tovey, Director The Basement Information Centre
Simplifying design and construction Alan Tovey, Director The Basement Information Centre Simplifying design and construction Grades of construction Construction options Design and waterproofing issues
WATERPROOFING FOR CONCRETE STRUCTURES
MANUAL OF CONTRACT DOCUMENTS FOR ROAD WORKS VOLUME 1 SPECIFICATION FOR ROAD WORKS SERIES 2000 WATERPROOFING FOR CONCRETE STRUCTURES Contents Clause Title Page 2001 General 2 2002 Protection of Bridge Deck
Emergency Spillways (Sediment basins)
Emergency Spillways (Sediment basins) DRAINAGE CONTROL TECHNIQUE Low Gradient Velocity Control Short-Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent [1] [1]
HIGHWAYS DEPARTMENT GUIDANCE NOTES ON THE USE OF WATERPROOFING MEMBRANES ON CONCRETE BRIDGE DECKS
HIGHWAYS DEPARTMENT GUIDANCE NOTES ON THE USE OF WATERPROOFING MEMBRANES ON CONCRETE BRIDGE DECKS Research & Development Division RD/GN/033 June 2008 THE USE OF WATERPROOFING MEMBRANES ON CONCRETE BRIDGE
ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R00060057. Lecturer: Jim Cahill
ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R00060057 Lecturer: Jim Cahill 29 th November 2011 TABLE OF CONTENTS SUMMARY 1 MAIN BODY SECTION
PERMEABLE INTERLOCKING CONCRETE PAVEMENT
[NOTE TO SPECIFICATION WRITER: This guide specification for the use of permeable interlocking concrete pavers for pedestrian and vehicular traffic application was developed based on the use of an open-graded
SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS
SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING
CONCRETE SEGMENTAL RETAINING WALL SYSTEM
CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Classic 8 with PCS unit segmental retaining wall
September 2007. September 2013. Consulting Structural and Civil Engineers. 100 St John Street London EC1M 4EH. info @ akt-uk.com www.akt-uk.
Consulting Structural and Civil Engineers 100 St John Street London EC1M 4EH T +44 (0) 20 7250 7777 F +44 (0) 20 7250 7555 info @ akt-uk.com www.akt-uk.com 3290 A031234 The 196-222 Joseph Kings Bloggs
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
Uniclass L7315 + L2123 EPIC J3413. CI/SfB (52.5) Heavy duty channel drainage system ACO S Range
Uniclass L7315 + L2123 EPIC J3413 CI/SfB (52.5) Heavy duty channel drainage system ACO S Range ACO S Range CHANNEL DRAINS Load Class BS EN 1433:2002 Optimum solution The ACO S Range is an interconnecting
100.02 Civil engineering Fibertex Geotextiles
C O N S T R U C T I O N 100.02 Civil engineering C O N S T R Constructing with Fibertex offers a full range of nonwoven geotextiles designed for use in many different foundation structures within civil
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown
asphalt applications Construction and surfacing of footways and cycleways using asphalt mpa asphalt Asphalt Information Service
asphalt applications 11 Construction and surfacing of footways and cycleways using asphalt Asphalt Information Service mpa asphalt November 2009 Mineral Products Association Introduction The main use of
constructive solutions Fosroc total waterproofing protection of below-ground structures
constructive solutions Fosroc total waterproofing protection of below-ground structures Our profile Since the company s beginnings over 50 years ago, Fosroc has developed into an International leader in
Roofing Systems. New Applications / Re-Roofing / Maintenance
Roofing Systems New Applications / Re-Roofing / Maintenance New Roof Installation In terms of the design and installation of an original roofing system (in conjunction with the construction of a new building),
CONCRETE SEGMENTAL RETAINING WALL SYSTEM
CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Vintage TM unit segmental retaining wall (SRW)
SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING. 16.1 General...16-1. 16.2 Materials...16-1. 16.3 Equipment...
SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING TABLE OF CONTENTS 16.1 General...16-1 16.2 Materials...16-1 16.3 Equipment...16-1 16.4 Installation...16-2 16.4.1 Traffic Restrictions...16-2
Permeable Pavement Construction Guide
Permeable Pavement Construction Guide Permeable pavement at Olympic Park, Waitakere Final Construction result What are permeable pavements? Permeable pavements are hard surface paving systems that reduce
SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)
SPECIFICATIONS INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP) Part 1 General 1.1 CONFORMITY Conforms to the requirements of the general conditions of the contract.
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
Installation Guidelines for Segmental Block Wall. Contents 1. INTRODUCTION... 2 2. MATERIALS... 2
Johannesburg +27 (0)11 922 3300 Pinetown +27 (0)31 717 2300 Cape Town +27 (0)21 531 8110 East London +27 (0)43 727 1055 www.kaytech.co.za Installation Guidelines for Segmental Block Wall Contents 1. INTRODUCTION...
HIGHWAYS DEPARTMENT GUIDANCE NOTES ON ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS AND HIGH SPEED ROADS
HIGHWAYS DEPARTMENT GUIDANCE NOTES ON ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS AND HIGH SPEED ROADS Research & Development Division RD/GN/032 June 2007 1. Purpose ROAD SURFACE REQUIREMENTS FOR EXPRESSWAYS
SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.
SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS Prepared by Risi Stone Systems Used by permission. 1-800-UNILOCK www.unilock.com FOREWORD This outline specification has been prepared for
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
Dimensional and Structural Data for Elliptical Pipes. PD 26 rev D 21/09/05
Dimensional and Structural Data for Elliptical Pipes 21/09/05 Page 1 of 15 1. Foreword This document details a method for the structural design of Stanton Bonna Elliptical pipes for the common conditions
Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA 18000 / Israel. J. Magner Dipl.-Ing. N. Machill.
Kiwa Polymer Institut GmbH Quellenstraße 3 65439 Flörsheim-Wicker Tel. +49 (0)61 45-5 97 10 Fax +49 (0)61 45-5 97 19 www.kiwa.de Test report P 7013-E Testing order: Test of the waterproofing system based
Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades
Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial
R E S I D E N T I A L H O U S I N G
HL 252 Rev. April 1997 R E S I D E N T I A L H O U S I N G CONTROLLING EXTERNALWATER PROBLEMS FOR RESIDENCES I II III IV V Lot Drainage Gutter Water Management Foundation Waterproofing Floor Slab Waterproofing
Construction Specification for Concrete Curb and Concrete Curb and Gutter
Engineering & Construction Services Division Standard Specifications for Road Works TS 3.50 April 2015 for Concrete Curb and Table of Contents TS 3.50.01 SCOPE... 3 TS 3.50.02 REFERENCES... 3 TS 3.50.03
SPECIFICATION FOR CONSTRUCTION OF UNBOUND GRANULAR PAVEMENT LAYERS
TNZ B/02:2005 SPECIFICATION FOR CONSTRUCTION OF UNBOUND 1. SCOPE This specification shall apply to the construction of unbound granular pavement layers. The term pavement layer shall apply to any layer
Installation PowerPoint for Grasscrete Formers
Installation PowerPoint for Grasscrete Formers 1 This document describes the two single-use tools utilized to create the Grasscrete product. The original Former is a vacuum formed light gauge plastic mold
Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure
Basements are Changing John Straube, Ph.D., P.Eng Basements: New & Retrofit Energy Efficient, Durable, Healthy Increasingly used as living space Not a root /coal cellar anymore! High quality space expected
BMP #: Dry Wells / French Drains
Structural BMP Criteria BMP #: Dry Wells / French Drains A Dry Well, or French Drain, is a variation on an Infiltration Trench that is designed to temporarily stores and infiltrate rooftop runoff. Key
RIPRAP From Massachusetts Erosion and Sediment Control Guidelines for Urban and Suburban Areas http://www.mass.gov/dep/water/laws/policies.
RIPRAP From Massachusetts Erosion and Sediment Control Guidelines for Urban and Suburban Areas http://www.mass.gov/dep/water/laws/policies.htm#storm Definition: A permanent, erosion-resistant ground cover
NEUPAVE. Permeable Pavers. A Permeable Eco-Friendly Beauty
NEUPAVE Permeable Pavers A Permeable Eco-Friendly Beauty As the first in Malaysia to manufacture this new paving technology, is a paving alternative to more traditional types of hardscape flooring materials,
Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description
Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing
High Performance PSA in Sheet Membrane in Water Protection
High Performance PSA in Sheet Membrane in Water Protection Xia Cao, Senior R&D Chemist, W. R. Grace, Cambridge MA 02140 Jyoti Seth, Strategic Program Leader, W. R. Grace, Cambridge MA 02140 Concrete is
USE OF GEOSYNTHETICS FOR FILTRATION AND DRAINAGE
USE OF GEOSYNTHETICS FOR FILTRATION AND DRAINAGE Prof. G L Sivakumar Babu Department of Civil Engineering Indian Institute of Science Bangalore 560012 Functions of a Filter Retain particles of the base
Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.
Design Guide Basis of Design This section applies to the design and installation of earthwork and backfill. Design Criteria No stockpiling of excavation materials is allowed unless the Geotechnical Engineer
What you need to know about concrete block basement construction.
Designing and planning your new residence is a vitally important process, which will have a great influence on the future enjoyment of your home. A successful process will ensure all areas of the home
AquaPaver & SF-Rima Permeable Interlocking Concrete Pavers
F.P.O. Need SF-Rima THE TREMRON GROUP Permeable Paver Guide AquaPaver & SF-Rima Permeable Interlocking Concrete Pavers MIAMI 11321 NW 112th Court Medley, FL 33178 800.567.1480 or 305.825.9000 Fax 305.823.6614
Guidelines to Green Roofing
The Green Roof Organisation (GRO) Excellence in Green Roofs Guidelines to Green Roofing GRO is a partnership of Industry and Stakeholders coming together to develop guidance for specification, design,
A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.
BMP: SUBSURFACE DRAIN Definition A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. PurRoses 1. To prevent sloping soils from becoming
BMP 6.4.6: Dry Well / Seepage Pit
BMP 6.4.6: Dry Well / Seepage Pit A Dry Well, or Seepage Pit, is a variation on an Infiltration system that is designed to temporarily store and infiltrate rooftop runoff. Key Design Elements Fllow Infiltration
Modular Geo-Void Systems Total Water Management
Modular Geo-Void Systems Total Water Management A Precipitation Collection System and Versatile Void Former Reduces Urban flooding and water contamination Modular design provides easy installation Civil
GUIDE SPECIFICATIONS FOR CONSTRUCTION OF AQUAPAVE PERMEABLE STORMWATER MANAGEMENT SYSTEM
GUIDE SPECIFICATIONS FOR CONSTRUCTION OF AQUAPAVE PERMEABLE STORMWATER MANAGEMENT SYSTEM SECTION 32 14 13.19 AquaPave Permeable Interlocking Concrete Pavement Note: This guide specification is for the
Site Grading and Drainage to Achieve High-Performance Basements
Construction Technology Update No. 69 Site Grading and Drainage to Achieve High-Performance Basements By M.C. Swinton and T.J. Kesik Proper site grading and foundation drainage strategies are required
Stormwater/Wetland Pond Construction Inspection Checklist
: Construction Inspection ChecklistsTools Stormwater/Wetland Pond Construction Inspection Checklist Project: Location: Site Status: Date: Time: Inspector: SATISFACTORY/ UNSATISFACTORY COMMENTS Pre-Construction/Materials
Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY.
Compression load testing straw bale walls Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY May 2004 1. Introduction Over the last 10 years a growing number of loadbearing
A Guide to Structural Waterproofing
A Guide to Structural Waterproofing Part One Waterproofing Protection For Below Ground Structures 1 2012 W. R. Grace & Co Benjamin J. Brooks Table of Contents Grace Around The World Reference Material
piles of debris that accumulate after a rain such as leaves, trash, twigs, etc., water stains on fences and buildings, or salts extruded on bricks,
Extension Education Center 423 Griffing Avenue, Suite 100 Riverhead, New York 11901-3071 t. 631.727.7850 f. 631.727.7130 ASSESSING DRAINAGE PROBLEMS How can you tell the difference between a drainage problem
opti-drän system Keeps your basement and building dry
opti-drän system Keeps your basement and building dry Last modified: January 0 DRAINAGE SYSTEMS ELECTRICAL SYSTEMS BUILDING TECHNOLOGY INDUSTRIAL PRODUCTS Professional building drainage with the opti-drän
Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps
Foundations on Expansive Clay Soil Part 3 - Investigation of Failed Foundations Presented by: Eric Green, P.E. Structural Engineer Slide 1 Copyright Eric Green 2005 Investigation of Foundation Failure
Regulations Detail Sheet 1
Designated by Government to issue European Technical Approvals Esha (UK) Ltd Esha House St Mary s Business Park Albany Road Market Harborough Leicestershire LE16 7EB Tel: 01858 410372 Fax: 01858 410572
Session 7: Retrofitted Edge Drains 7.1
Session 7: Retrofitted Edge Drains 7.1 Learning Outcomes 1. List benefits of drainage 2. List components of edge drain systems 3. Describe recommended installation procedures 4. Identify typical construction
Reinforcement HUESKER. HaTelit. Engineering with geosynthetics
HUESKER Engineering with geosynthetics rhuesker HUESKER HUESKER HUESKER HUESKER HUESKERr SKER HUESKER HUESKER Asphalt HUESKER HUESKER HUESKERHUES Reinforcement - the answer to reflective cracking in asphalt
How To Test A Wrap N Drain X Dampproofing System
National Research Council Canada Institute for Research in Construction Conseil national de recherches Canada Institut de recherche en construction CCMC 13094-R &&0& EVALUATION DIVISION 07111 REPORT Issued
EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES
Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING
Systems. For drainage and hydroponic applications. BRITISH WATER expertise worldwide. email: [email protected] web: www.naylor.co.
Systems For drainage and hydroponic applications Strong Lightweight Versatile Cost effective Easy to install email: [email protected] web: www.naylor.co.uk BRITISH WATER expertise worldwide Strength
INTERIM ADVICE NOTE 96 /07 Revision 1 GUIDANCE ON IMPLEMENTING RESULTS OF RESEARCH ON BRIDGE DECK WATERPROOFING
Interim Advice Note 96/07 INTERIM ADVICE NOTE 96 /07 Revision 1 GUIDANCE ON IMPLEMENTING RESULTS OF RESEARCH ON BRIDGE DECK WATERPROOFING Summary This interim advice note provides guidance on improving
Porous Pavement Alternatives Cost Analysis
Porous Pavement Alternatives Cost Analysis Prepared by Century West Engineering for Metro This cost analysis compares the construction costs of six different types of pavement for three different scenarios.
Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
ALKS SIDEW II. TK TK TK TK TK TK TK TK 40 BOSTON COMPLETE STREETS GUIDELINES DRAFT - JULY 2011 BOSTON TRANSPORTATION DEPARTMENT
40 Sidewalk Materials Materials and Sidewalk Zones Permeable Pavement Accessibility The key components of sidewalk construction are material selection and installation. These two aspects should come together
Liner system design for tailings impoundments and heap leach pads
Liner system design for tailings impoundments and heap leach pads John F. Lupo, Ph.D., P.E. AMEC E&E TAILINGS & MINE WASTE 08, VAIL Liner Systems Liner systems Environmental containment of process solutions
Drainage A Crucial Component for Athletic Field Performance. Part Three: Sub-Surface Installed Drainage Systems
www.stma.org Drainage A Crucial Component for Athletic Field Performance Part Three: Sub-Surface Installed Drainage Systems Water is applied to maintained turfgrass areas by irrigation or precipitation.
INSTALLATION GUIDE. americanwick.com 800.242.WICK (9425)
INSTALLATION GUIDE americanwick.com 800.242.WICK (9425) American Wick Drain SITEDRAIN prefabricated drainage products may be installed in a variety of civil construction applications including: retaining
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
Product Guide Specification
Reef Industries, Inc. 9209 Almeda Genoa Rd. Houston, Texas 77075 Toll Free (800) 231-6074 Phone (713) 507-4251 Fax (713) 507-4295 Web Site www.reefindustries.com E-Mail [email protected] Product Guide