PS3 Peptide Synthesizer QUICK START GUIDE
|
|
|
- Ariel Waters
- 10 years ago
- Views:
Transcription
1 PS3 TM Peptide Synthesizer QUICK START GUIDE
2
3 TM PS3 Peptide Synthesizer QUICK START GUIDE
4 2006 Protein Technologies, Inc S. Coach Dr. Tucson, AZ USA All Rights Reserved. DOC # Rev 01
5 WARNING THIS INSTRUMENT CONTAINS SOLVENTS AND CHEMICALS THAT SHOULD BE HANDLED CAREFULLY. MANY ARE EASILY ABSORBED THROUGH THE SKIN AND CAN CAUSE ADVERSE HEALTH EFFECTS. WEAR SAFETY GLASSES, PROTECTIVE CLOTHING AND RUBBER GLOVES AT ALL TIMES. FOLLOW MSDS HANDLING GUIDELINES PROVIDED WITH THE INDIVIDUAL REAGENTS. RESPIRATORS AND ABSORBENT SHOULD BE AVAILABLE IN THE EVENT OF A SPILL. WARNING DO NOT ATTEMPT TO MOVE THE PS3 WHILE ANY OF THE SOLVENT OR WASTE CONTAINERS CONTAIN LIQUIDS.
6
7
8
9 Contents Contents...v Introduction...7 I.1 About This Book...7 I.2 About The Company...7 Chapter 1: Instrument Layout PS3 TM Front PS3 TM Left Side PS3 TM Right Side...10 Chapter 2: Accessories Reaction Vessels Empty Amino Acid Vial Pre-Packed Amino Acid Vials & Reagents for Peptide Synthesis Replacement Parts/Accessories...12 Chapter 3: Basic Synthesis Setup Startup & Instrument Check Instrument Setup Reaction Vessel Installation Amino Acid Vial Installation Software Setup Bottle Preparations Set Amino Acid Vial Positions Edit Programs Assign Programs Set Universal Times Turn on Printer Start A Synthesis Post-Synthesis Procedures Cleaning and Replacement of Inline Filters...24 Appendix...27 A.1: PS3 TM Pre-Packed N-Fmoc-Protected Amino Acids and HBTU, Preweighed...27 A.2: Bulk N-Fmoc-Protected Amino Acids, Preweighed...28 A.3: Reagents & Kits...29 A.4: Replacement Parts & Accessories...29 v
10 vi
11 Introduction Thank you for purchasing your new PS3 TM from Protein Technologies, Inc. The PS3 TM is a fully automated microprocessor-controlled instrument for synthesizing peptides using solid phase synthesis principles. It is designed for users with minimal experience with peptide synthesis. The PS3 TM allows for total flexibility in choosing synthesis scale, coupling conditions, deprotection conditions, wash steps, and reagent volumes. Standard chemical protocols are included in the software, and pre-weighed reagents for these protocols are provided in convenient disposable containers. I.1 About This Book This book helps you to get started with the PS3 TM Chapter 1, Instrument Layout, introduces you to the basic layout of the PS-3 TM Chapter 2, Accessories, introduces you to the accessories offered on the PS-3 TM. Chapter 3, Basic Synthesis Setup, introduces you to the basic software and procedures required to set up a synthesis on the PS3 TM. I.2 About The Company Protein Technologies, Inc. (PTI) is a private company based in Tucson, Arizona. Founded in 1985 by researchers affiliated with the University of Arizona, PTI has a long history of developing and manufacturing high quality peptide synthesizers. Our instruments are used in major universities, pharmaceutical companies and biotechnology companies worldwide. We support our products with a dedicated field service team and are proud of our reputation for reliability. We value the trust our customers and partners have placed in PTI. Today, we continue to grow and innovate to serve the needs of the solid-phase synthesis market. 7
12
13 Chapter 1: Instrument Layout 1.1 PS3 TM Front RVs and Grommets N 2 Ports Display and Keypad Needle Delivery Lines and Inlet Ports Needles and Injector Power and Printer Ports Amino Acid Vials Bottle Holder 1.2 PS3 TM Left Side Carousel Nitrogen Inlets Delivery Tubes Needle Filter Housings Waste Ports 9
14 PS3 TM Right Side Printer Parallel Port On/Off Switch Printer Power Port Power Port 10
15 Chapter 2: Accessories 2.1 Reaction Vessels 30 ml Cat#: PS , 1 ea. 75 ml Cat#: PS , 1 ea. 2.2 Empty Amino Acid Vial Vial with Cap & Septa Cat#: PS3-VX-010, Pkg. of 10 Cat#: PS3-VX-100, Pkg. of Pre-Packed Amino Acid Vials & Reagents for Peptide Synthesis Protein Technologies, Inc. supplies high quality, pre-tested N-Fmoc-protected amino acids preweighed with equimolar amounts of HBTU activator in and quantities in pre-packed vials (see Appendix A.1 for listings). PTI also supplies bulk N-Fmoc-protected amino acids preweighed in and quantities (See Appendix A.2 for listings) and reagents for peptide synthesis on 11
16 the PS3 TM (See Appendix A.3 for listings). We recommend using our amino acids and reagents for all of your synthesis needs. 2.4 Replacement Parts/Accessories Protein Technologies, Inc. supplies replacement parts for the PS3 TM, as well as various accessories, including solvent/reagent bottles and waste containers. A partial listing of replacement parts and accessories is located in Appendix A.4. For additional part and accessory information, please call our support desk at
17 Chapter 3: Basic Synthesis Setup 3.1 Startup & Instrument Check To startup the PS3 TM Peptide Synthesizer: 1. Turn on the power switch located on the right side of the instrument. The synthesizer will go through its self-check by moving the carousel around to home or position 1. It will display the message: FINDING CAROUSEL HOME POSITION PLEASE WAIT 2. After the carousel has stopped at the home position, the screen will display: 1) EDIT AND RUN 2) MANUAL OPERATION 3) BOTTLE PREPARATION 4) SET UP 3. Check the nitrogen supply, waste level, and inline solvent and injector filters. The nitrogen pressure should be greater than 70 psi, and there should be enough nitrogen in the tank for the synthesis. The waste tank should be empty, and the inline solvent and injector filters should be cleaned and replaced after each synthesis. IMPORTANT The filters for the injector needles should be cleaned or replaced after each synthesis. Particles may cause valve malfunction and may damage the synthesizer (See Section 3.5). 13
18 Instrument Setup Reaction Vessel Installation Elbow Connector 1 Screw Cap Reaction Vessel 2 Connector 1. Place RV top flush into top connector. Tighten connector hand tight. 2. Place RV bottom flush into bottom connector. Tighten connector hand tight. To remove, loosen connectors one at a time and remove the RV Amino Acid Vial Installation The capped amino acid vial contains five parts: O-Ring Screw Cap Septa Washer Vial 14
19 To assemble the capped vial: Place the septa into the cap. 2. Put the o-ring over the washer and drop the washer into the cap on top of the septa. 3. Screw the cap onto the vial tightly. Place filled amino acid vials into the carousel in the order of the peptide sequence from the C-terminus to the N-terminus. The first amino acid to couple should be placed in position 1. Check to make sure each vial fits under the injector port. Repeat for up to three peptides. Make sure the amino acids are in order for each peptide. Do not skip carousel positions. NOTE The PS3 TM can use one, two or three RVs, but they must be in order. An example is RV 2 then RV 3 or RV 2 only. The PS3 TM cannot synthesize on RV 1 and then RV 3. If double coupling will be performed, place two vials of the given amino acid in the sequence. For example, if a peptide with the sequence, PEPTIDE, is going to be synthesized, and double coupling is desired for D, the amino acid vials should be placed in the carousel as follows: Position Amino Acid Vial 1 E 2 D 3 D 4 I 5 T 6 P 7 E 8 P The carousel has room for 45 amino acid vials. If more positions are required, the instrument must be reloaded and restarted as a new synthesis. 15
20 If final deprotection is desired, place an empty amino acid vial after the last amino acid in a peptide. If capping is desired after a coupling, add acetic anhydride to a clean, empty vial and put it in the carousel following the coupled amino acid. For a scale synthesis use 2 ml of acetic anhydride. 3.3 Software Setup Bottle Preparations 1. Install the two SOLV bottles, ACT bottle and DEP bottle on the instrument. Each bottle should contain the following reagents: SOLV: 4 L of DMF ACT: 0.9 L of 0.4 M N-methylmorpholine in DMF (Cat #: PS3-MM-L) DEP: 0.9 L of 20% piperidine in DMF (Cat #: PS3-PPR-L) 2. From the main menu, press 3 or use the arrow buttons to move to BOTTLE PREPARATION then press ENTER. BOTTLE PREPARATION PRESSURE SOLV DEP ACT ALL PRIME SOLV DEP ACT ALL VENT SOLV DEP ACT ALL 3. Use the right arrow button to move the cursor to the ALL column for PRESSURE and press RUN. The bottles will pressurize starting with SOLV then DEP and ACT. 4. SOLV will take approximately 1 minute to pressurize. DEP and ACT will take approximately 30 seconds each. 5. Move the cursor down to the PRIME row then use the right arrow button to move to the ALL column and press RUN. 6. Press the EXIT button to return to the MAIN MENU. 16
21 Set Amino Acid Vial Positions 1. From the MAIN MENU, press 1 to open the EDIT AND RUN menu. First amino acid vial position Second amino acid vial position RV AA PRG REAG STAT TIMER REP STOP SOLV FILL 0:00: SOLV FILL 0:00: SOLV FILL 0:00: Under the AA column, enter the carousel position number that contains the first amino acid to be coupled to the resin (C-terminus). Enter 2 digits such as 03 instead of Use the right arrow button to move the cursor to the STOP column. 4. Enter the carousel position number that contains the last amino acid vial (N-terminus) for that RV. NOTE For final deprotection, add an empty vial after the last amino acid of a peptide and enter the empty vial position in the STOP column. 5. Repeat steps 2-4 for each RV Edit Programs The standard programs for single coupling, double coupling, final deprotect, and capping are as follows: Program 3 (Single Coupling) STEP REAG TIMER REP COMMENTS 1 SOLV 0:00:30 3 Washes resin 2 DEP 0:05:00 2 Deprotects N terminus 3 SOLV 0:00:30 6 Washes resin 4 ACT 0:00:30 1 Dissolves AA/HBTU with base 5 AA 0:20:00 1 AA coupling 6 SOLV 0:00:30 3 Washes resin 17
22 Program 4 (Double Coupling) STEP REAG TIMER REP COMMENTS 1 SOLV 0:00:30 3 Washes resin 2 DEP 0:05:00 2 Deprotects N terminus 3 SOLV 0:00:30 6 Washes resin 4 ACT 0:00:30 1 Dissolves AA/HBTU with base 5 AA 0:20:00 1 AA coupling 6 ACT 0:00:30 1 Dissolves AA/HBTU with base 7 AA 0:20:00 1 AA coupling 8 SOLV 0:00:30 3 Washes resin Program 5 (Final Deprotect) STEP REAG TIMER REP COMMENTS 1 SOLV 0:00:30 3 Washes resin 2 DEP 0:05:00 2 Deprotects N terminus 3 SOLV 0:00:30 6 Washes resin Program 6 (Capping) STEP REAG TIMER REP COMMENTS 1 SOLV 0:00:30 3 Washes resin 2 ACT 0:00:30 1 Mixes Capping Reagent 3 AA 0:20:00 1 Caps resin 4 SOLV 0:00:30 3 Washes resin IMPORTANT During an AA step, ACT solution is first delivered to the amino acid vial, then the dissolved mixture is transferred to the RV. The amino acid vial is then rinsed with an equal volume of SOLV, which is also transferred to the RV before the mixing begins. If different reaction times or repetitions are desired, you may edit the programs as follows: 1. In the EDIT AND RUN screen, press the EDIT button. A screen will open: EDIT WHICH PROGRAM? 1, 2, 3, 4, 5, CAP 6 2. Select the program to edit by pressing the number on the keypad then ENTER. If single couplings will be used, edit program 3. If double couplings will be used, edit program 4. If a final deprotect will be performed, edit program 5. If capping will be used, edit program The screen will display the first line of the program in the RV 1 line, and the cursor will be in the TIMER column. 18
23 Program steps will be displayed in this line only RV AA PRG REAG STAT TIMER REP STOP SOLV FILL 0:00: SOLV FILL 0:00: SOLV FILL 0:00: Use the left or right arrows to move between the TIMER and REP columns. Use the up or down arrows to scroll through the steps. Use the keypad to enter different times or repetitions. NOTE Amino acid vials have a capacity of 5 ml. 3 ml is the default ACT delivery volume resulting in 6 ml total coupling solution being delivered to the RV during an AA step (3 ml ACT and 3 ml SOLV). If a larger volume is needed, the REP can be changed in the AA step to deliver another volume of ACT to the same AA vial and transfer it to the RV prior to the SOLV rinse. 5. When finished making changes, press the EXIT button. A new screen will display: STORE AS PROGRAM 7, 8, 9, 10 11, 12, 13, 14, or 15? OR ENTER 0 FOR NO CHANGE 6. Enter the number of a program file to save the changes. There are 9 program files available for use (7-15). Press 0 if the program is not to be saved. 7. The STORE AS PROGRAM screen will close and the EDIT AND RUN screen will open. Be sure to create a swelling program to swell the resin before a synthesis. Do this by editing the first step of the program that will be used for the first coupling so that SOLV is mixed for 0:10:00 instead of 0:00: Assign Programs Each amino acid position must have a program assigned to it. To assign programs in the EDIT AND RUN screen: 1. Use the arrow keys to move the cursor to the designated RV and press the ASSIGN button. 2. The cursor will move to the PRG column. Use the keypad to type in the two-digit program for the first amino acid position. 19
24 NOTE Be sure to assign a swelling program to the first amino acid for each RV (Section 3.3.3). 3. Press the down arrow button to change to the next amino acid position (indicated in the AA column) and type in the two digit program for the second amino acid position. Continue until all amino acid positions have a selected program. 4. Press the EXIT button to exit the assign a program section. The cursor will return to the AA column. 5. Repeat steps 1-4 to assign programs to different RVs. 6. Press the EXIT button to return to the MAIN MENU. NOTE Double coupling programs automatically use the assigned amino acid position and the following position. The double coupling program automatically overwrites any program assigned to the second amino acid position, but for clarity it is suggested that the same program be assigned to the first and second coupling positions. NOTE If capping is desired, add acetic anhydride to a clean, empty vial and put it in the carousel following the amino acid. For a scale synthesis use 2 ml of acetic anhydride. The capping program will add an aliquot of ACT reagent to the vial, then transfer the mixed solution to the RV. (Program 4 or 6) NOTE If a final deprotect is desired, place an empty amino acid vial after the last vial for a peptide, and assign a final deprotect program to that position. (Program 5) Set Universal Times To determine the volume of fluid and drain time necessary for the synthesis, add the amount of resin for the synthesis to an RV and adjust the fill and disposal times using MANUAL OPERATIONS. NOTE Each RV should have the same synthesis scale to ensure the proper volume of solvent/reagent is added to saturate the resin. 1. From the MAIN MENU, press 2 to open MANUAL OPERATIONS then press 3 to open REACTION VESSEL CONTROL. 20
25 Enter Fill Time Enter Drain Time FILL MIX DISP REP RV 1 SOLV 07 0:00: RV 2 SOLV 05 0:00: RV 3 SOLV 05 0:00: Move the cursor to thefill column and press enter until SOLV is displayed. Move the cursor to the two-digit number to the right of SOLV and change the fill time (in seconds) then move the cursor to the DISP column to change the drain time (in seconds). Set the MIX time to 0:00:30. Always have the DISP time greater then the SOLV to drain all the fluid. NOTE One second of fill time equals approximately 1 ml of fluid. NOTE The DISP time should typically be twice as long as the FILL time. 3. Press RUN. Check the volume of fluid in the RV. If necessary, repeat with different times. 4. Once you have determined the proper FILL and DISP times, press EXIT twice and press 4 for SETUP and then press 1 for SET UNIVERSAL TIMES. REAG WASH 07 SOLV FILL 07 CLEAR 10 RV WASH 05 DEP FILL 07 DISPOSE 14 VENT WASH 05 ACT FILL 3 MIX ON 01 AA WASH 05 MX RV VOL 35 MIX OFF Change REAG WASH, SOLV FILL, and DEP FILL times to the new FILL time determined in MANUAL OPERATION. Change DISPOSE to the new time for DISP determined in MANUAL OPERATION. 6. Press EXIT twice to return to the MAIN MENU Turn on Printer Turn on the printer to record the steps in the synthesis. It will also report error messages. 1. From the MAIN MENU press 4 then press 2 to open PRINTER OPERATIONS. 21
26 ) PRINTER ON 2) PRINT USER PROGRAMS 3) PRINT FIXED PROGRAMS 4) PRINT ALL PROGRAMS 2. Press 1 or press ENTER to turn the printer on. NOTE If line 1 reads PRINTER OFF than the printer is already on. 3. Press EXIT twice to return to the MAIN MENU Start A Synthesis After all RV(s) have been loaded with resin, amino acids positions and programs have been assigned, the carousel loaded, and the bottles pressurized and primed, the synthesis may be started. 1. Press 1 or ENTER in the MAIN MENU to open the EDIT AND RUN screen. RV AA PRG REAG STAT TIMER REP STOP SOLV FILL 0:00: SOLV FILL 0:00: SOLV FILL 0:00: The cursor will be under the AA column for RV 1. Move the cursor to the RV row to start, then press RUN. 3. The synthesis will start. 3.4 Post-Synthesis Procedures After a synthesis is complete: 1. Remove the RVs from the PS3 TM and move them to a fume hood for cleavage. Replace with empty RVs. Remove used amino acid vials. 2. Place an empty, fully assembled amino acid vial in the carousel. Move the vial under the injector as follows: a. Press EXIT to return to the MANUAL OPERATION screen. Press 2 to enter the AMINO ACID SYSTEM CONTROL screen. 22
27 1) ADVANCE CAROUSEL 2) GO TO CAROUSEL POSITION # 3) INJECT POSITION 4) UP POSITION b. Press 2 to select GO TO CAROUSEL POSITION # c. Type in the position number of the empty amino acid vial and press RUN to move it under the injector. Use two digits when entering in position number. CAUTION Needle can cause serious damage. Keep hands away from the needle. 3. Perform an AA INJECTOR wash as follows: a. Press EXIT to return to MANUAL OPERATION screen, then press 1 to select WASH PROGRAMS. b. Press 6 for AA INJECTOR wash. 4. When complete, clear bottle lines as follows: a. Vent all bottles using the BOTTLE PREPARATION screen. (Press EXIT twice to return to the MAIN MENU, then press 3 to select BOTTLE PREPARATION.) BOTTLE PREPARATION PRESSURE SOLV DEP ACT ALL PRIME SOLV DEP ACT ALL VENT SOLV DEP ACT ALL b. Use the arrow buttons to move the cursor to the ALL column for VENT and press RUN. The bottles will vent starting with SOLV then DEP and ACT. 5. Discard or store used chemicals. 6. Empty the waste container. 7. Turn off synthesizer. NOTE The PS3 TM bottles must be vented when not in use. If nitrogen pressure is lost while the bottles are pressurized, bottles may leak, causing damage to the instrument. 23
28 Cleaning and Replacement of Inline Filters There are five inline filters on the PS3 TM. One for each of the three reaction vessels and one for each of the two injection needles. To Injection Needles To Reaction Vessels Injection Needle Filters Reaction Vessel Filter To Waste To check inline filters for particulates: 1. Unscrew the fitting from the cap, then unscrew the cap from the housing. To PS3 Housing Washer Filter Cap Fitting 2. If the filter is dirty, remove the washer and filter from the cap and wash with ethanol to remove particulate matter. 3. Place a new or clean filter in the cap with the washer over the filter and screw the cap back into the PS3 TM housing. 24
29 4. Screw the fitting with the tube into the cap. Do not use tools to tighten the fittings and cap. Avoid over-tightening. To check for leaks: 1. Turn on PS3 TM. 2. From the MAIN MENU, press 3 to select BOTTLE PREPARATION. Pressurize and prime SOLV and ACT by making the appropriate selection and pressing RUN. 3. Press EXIT to return to the MAIN MENU. Press 2 then press 3 to open REACTION VESSEL CONTROL. 4. Under the FILL column, press ENTER until SOLV is displayed in each row. Press RUN for each row to deliver SOLV to all 3 RVs. Check for leaks. 5. Under the FILL column in row 1, press ENTER until ACT is displayed. Press RUN to deliver ACT to the empty amino acid cartridge. Check for leaks. 25
30
31 Appendix A.1: PS3 TM Pre-Packed N-Fmoc-Protected Amino Acids and HBTU, Preweighed Catalog No. Description Quantity PS3-H1-A FMOC-L-Ala/HBTU PS3-H5-A PS3-H1-RBF FMOC-L-Arg(Pbf)/HBTU PS3-H5-RBF PS3-H1-NT FMOC-L-Asn(Trt)/HBTU PS3-H5-NT PS3-H1-DB FMOC-L-Asp(OtBu)/HBTU PS3-H5-DB PS3-H1-CT FMOC-L-Cys(Trt)/HBTU PS3-H5-CT PS3-H1-EB FMOC-L-Glu(OtBu)/HBTU PS3-H5-EB PS3-H1-QT FMOC-L-Gln(Trt)/HBTU PS3-H5-QT PS3-H1-G FMOC-L-Gly/HBTU PS3-H5-G PS3-H1-HT FMOC-L-His(Trt)/HBTU PS3-H5-HT PS3-H1-I FMOC-L-Ile/HBTU PS3-H5-I PS3-H1-L FMOC-L-Leu/HBTU PS3-H5-L PS3-H1-KBC FMOC-L-Lys(Boc)/HBTU PS3-H5-KBC PS3-H1-M FMOC-L-Met/HBTU PS3-H5-M PS3-H1-F FMOC-L-Phe/HBTU PS3-H5-F PS3-H1-P FMOC-L-Pro/HBTU PS3-H5-P PS3-H1-SB FMOC-L-Ser(tBu)/HBTU PS3-H5-SB PS3-H1-TB FMOC-L-Thr(tBu)/HBTU PS3-H5-TB PS3-H1-WBC FMOC-L-Trp(Boc)/HBTU PS3-H5-WBC PS3-H1-YB FMOC-L-Tyr(tBu)/HBTU PS3-H5-YB PS3-H1-V FMOC-L-Val/HBTU PS3-H5-V 27
32 A.2: Bulk N-Fmoc-Protected Amino Acids, Preweighed Catalog No. Description Quantity B-25-A FMOC-L-Ala B-100-A B-25-RP FMOC-L-Arg(Pmc) B-100-RP B-25-RBF FMOC-L-Arg(Pbf) B-100-RBF B-25-NT FMOC-L-Asn(Trt) B-100-NT B-25-DB FMOC-L-Asp(OtBu) B-100-DB B-25-CT FMOC-L-Cys(Trt) B-100-CT B-25-EB FMOC-L-Glu(OtBu) B-100-EB B-25-QT FMOC-L-Gln(Trt) B-100-QT B-25-G FMOC-L-Gly B-100-G B-25-HT FMOC-L-His(Trt) B-100-HT B-25-I FMOC-L-Ile B-100-I B-25-L FMOC-L-Leu B-100-L B-25-KBC FMOC-L-Lys(Boc) B-100-KBC B-25-M FMOC-L-Met B-100-M B-25-F FMOC-L-Phe B-100-F B-25-P FMOC-L-Pro B-100-P B-25-SB FMOC-L-Ser(tBu) B-100-SB B-25-TB FMOC-L-Thr(tBu) B-100-TB B-25-W FMOC-L-Trp B-100-W B-25-WBC FMOC-L-Trp(Boc) B-100-WBC B-25-YB FMOC-L-Tyr(tBu) B-100-YB B-25-V FMOC-L-Val B-100-V 28
33 A.3: Reagents & Kits Catalog No. Description Quantity PS3-PPR-L 20% Piperidine/DMF (Dep) 0.9 L PS3-MM-L 0.4 N-Methylmorpholine/DMF (Act) 0.9 L B-100-HBTU B-500-HBTU B-1KG-HBTU B-100-HCTU B-500-HCTU B-1KG-HCTU PS3-HK5 PS3-HK1 PS3-STARTKIT HBTU HCTU Pack of H5 () amino acids: includes various quantities of the 20 amino acids. Pack of H1 () amino acids: includes various quantities for the 20 amino acids. Fmoc Amino Acid Start-up Kit for the PS3 TM. Contains: 5 each of H1 amino acids; 0.9 L Deprotectant; 0.9 L 0.4M NMM; HBTU; 3 of 0.1 mmol scale Rink amide resin, 1 of 0.1 mmol scale Fmoc-Gly-Wang resin. 500 g 1 kg 500 g 1 kg 1 ea. 1 ea. 1 ea. A.4: Replacement Parts & Accessories Catalog No. Description Quantity PS3-002 Teflon tubing (25 ft) 1 ea Membrane, Valve Manifold 1 ea Reaction Vessel (small scale 30 ml) 1 ea Reaction Vessel (large scale 85 ml) 1 ea. SMP RV Cap 1 ea Filter/Washer Set 1 ea O-Ring, SOLV, 4 L bottle 1 ea O-Ring, NMM & PIP (ACT & DEP, 1 L bottles) 1 ea O-Ring Schott (1 & 2 L bottles) 1 ea Reducing elbow connector, reaction vessel 1 ea Reducing straight connector, reaction vessel 1 ea. PS3-VX-010 Reagent vial, cap & septa Pkg. of 10 PS3-VX-100 Reagent vial, cap & septa Pkg. of 100 PS3-VX-500 Reagent vial, cap & septa Pkg. of 500 PS3-SEP100 Vial Septa Pkg. of 100 PS3-SEP500 Vial Septa Pkg. of 500 SMP Bottle amber, 4 L 1 ea. SMP Bottle amber, 1 L 1 ea. SMP Cap, SOLV and ACT/DEP (new style) 1 ea. SMP ACT/DEP (old style) 1 ea. SMP-RF-100 Bottle Filter Pkg. of 100 SMP Filter Housing, Bottle 1 ea. 29
34
35
36 North America 4675 S. Coach Dr. Tucson, AZ Phone: Toll Free: Fax: Europe Banbury, Oxfordshire, United Kingdom Phone: 44-(0) Website:
Prelude. Peptide Synthesizer USER MANUAL
Prelude X Peptide Synthesizer USER MANUAL Prelude X Peptide Synthesizer USER MANUAL 2015, Protein Technologies, Inc. 4675 S. Coach Dr. Tucson, AZ 85714 USA All Rights Reserved Document #9030024 Rev 01
Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options
Focus XC Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options FOCUS XC AUTOMATED PEPTIDE SYNTHESIZER aapptec s Focus XC is a compact, easy to use fully automated peptide synthesizer
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
Automated Fast-Bead Synthesis of Small Peptides
Automated Fast-Bead Synthesis of Small Peptides Application Note 228 Joan Stevens, Ph.D., Norbert Wodke, Tim Hegeman and Kirby Reed (Gilson, Inc.) Introduction In proteomic research, the synthesis of peptides
Peptide Synthesis Zheng Miao* and Zhen Cheng
Peptide Synthesis Zheng Miao* and Zhen Cheng 1 Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, USA *For correspondence: [email protected]
1) Technical informations. - a) How does it work? - b) Purification - c) Quality Control. 2) Standard synthesis
1) Technical informations - a) How does it work? - b) Purification - c) Quality Control 2) Standard synthesis - a) Standard peptides - b) Modified peptides - c) Shipment and Delivery Time - d) How to order?
CEM, First in Microwave Peptide Synthesis
CEM, First in Microwave Peptide Synthesis In 2002, a CEM biochemist named Jonathan Collins presented his concept of a microwave-assisted peptide synthesis system to several colleagues. Collins concept
Self Purging Liquid Trap (SPLT ) User s Manual
Self Purging Liquid Trap (SPLT ) User s Manual High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High
Watts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
ArtisanLink Staining System is an automated special stains slide
Technical Tips Tips on using the ArtisanLink Special Staining System Jamie Nowacek, BS, HT(ASCP) CM, QIHC, PMP Dako North America, Inc. Carpinteria, CA, USA ArtisanLink Staining System is an automated
ABI 433A Peptide Synthesis 3 ml Reaction Vessel. User s Manual
ABI 433A Peptide Synthesis 3 ml Reaction Vessel User s Manual Copyright 2001, Applied Biosystems. All rights reserved. For Research Use Only. Not for use in diagnostic procedures. ABI PRISM, the ABI PRISM
Overview'of'Solid-Phase'Peptide'Synthesis'(SPPS)'and'Secondary'Structure'Determination'by'FTIR'
verviewofsolid-phasepeptidesynthesis(spps)andsecondarystructuredeterminationbyftir Introduction Proteinsareubiquitousinlivingorganismsandcells,andcanserveavarietyoffunctions.Proteinscanactas enzymes,hormones,antibiotics,receptors,orserveasstructuralsupportsintissuessuchasmuscle,hair,and
Small μmol Scale Synthesis of a Labeled Antimicrobial Peptide using Biotage
Application ote A098 Small μmol Scale Synthesis of a Labeled Antimicrobial Peptide Page 1 Small μmol Scale Synthesis of a Labeled Antimicrobial Peptide using Biotage Initiator+ Alstra Introduction Labeled
Ultrasonic support removal tank
Ultrasonic support removal tank User guide and safety manual See inside for use and safety information. The Ultrasonic support removal tank automatically removes PLA support material from a printed ABS
Standard practices for Fmoc-based solid-phase. peptide synthesis in the Nowick laboratory. (Version 1.6.1)
Standard practices for Fmoc-based solid-phase peptide synthesis in the Nowick laboratory (Version 1.6.1) Adam G. Kreutzer and Patrick J. Salveson E-mail: Contents Contributions to this guide 3 General
UltraClean PCR Clean-Up Kit
UltraClean PCR Clean-Up Kit Catalog No. Quantity 12500-50 50 Preps 12500-100 100 Preps 12500-250 250 Preps Instruction Manual Please recycle Version: 02212013 1 Table of Contents Introduction... 3 Protocol
Installation Instructions 4662.003
Installation Instructions.00 SINGLE CONTROL KITCHEN FAUCET Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please
How To Replace A Reverse Osmosis Water Tank
ALL MODELS REVERSE OSMOSIS WITH NONAIRGAP FAUCET 1. Read all instructions carefully before starting installation. 2. Find the cold water line beneath your sink. The cold water is typically on the right.
Basic User Guide. Document Number D09665 Revision 01 July, 2012. For In Vitro Diagnostic Use
Basic User Guide Document Number D09665 Revision 01 July, 2012 For In Vitro Diagnostic Use Copyright 2012 Dako North America, Inc. All rights reserved This document may not be copied in whole or in part
l 4-minute cycle time l 90% solvent reduction Remarkably fast Automated Microwave Peptide Synthesizer
Automated Microwave Peptide Synthesizer CEM is transforming the way chemists perform peptide synthesis once again with the introduction of the Liberty Blue Microwave Peptide Synthesizer. More than just
www.servicechamp.com
1-800-221-0216 Fax: 1-800-472-2281 www.servicechamp.com Service Champ Part 52081 Service Interval every 30,000 miles / Chevrolet 1992-2002 6.5 liter Description and Operation The fuel filter element separates
experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.
81 experiment5 LECTURE AND LAB SKILLS EMPHASIZED Synthesizing an organic substance. Understanding and applying the concept of limiting reagents. Determining percent yield. Learning how to perform a vacuum
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Quick Start Guide See Inside for Use and Safety Information
3 rd Generation Personal 3D Printer Quick Start Guide See Inside for Use and Safety Information The USB Mass Storage Device Contains the User Guide and Quick Start Guide in other Languages Congratulations
Replacement Instructions ABI 431A/433A Waste Port
Replacement Instructions ABI 431A/433A Waste Port February 1996 (updated 09/2002) IMPORTANT Do not use the installation instructions contained within the waste port assembly packaging because they are
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
AIRFREE TECHNIQUE AND SENSITIVE REAGENTS S ECTI O N 1: GLASS W ARE A ND E Q UIP M ENT. A. Using a manifold
AIRFREE TECHNIQUE AND SENSITIVE REAGENTS S ECTI O N 1: GLASS W ARE A ND E Q UIP M ENT Some organic compounds are air sensitive. They can react with the water vapor or oxygen in the air. In order to perform
Disposable Insulin Delivery Device User Manual
PV 3734 AMP Disposable Insulin Delivery Device User Manual Instructions for Use Read and follow all of these instructions carefully. If you do not follow these instructions completely, you may get too
53403500 - Injector Max Machine
53403500 - Injector Max Machine Operating Instructions Contents Page Introduction Operating Instructions Fuel Injection Cleaner - Petrol Operating Instructions Fuel Injection Cleaner - Diesel 3 Operating
Experimental procedures. Solid phase peptide synthesis (SPPS)
Electronic Supplementary Material (ESI) for Organic & Biomolecular Chemistry This journal is The Royal Society of Chemistry 214 Experimental procedures Solid phase peptide synthesis (SPPS) Solid phase
Analysis of Liquid Samples on the Agilent GC-MS
Analysis of Liquid Samples on the Agilent GC-MS I. Sample Preparation A. Solvent selection. 1. Boiling point. Low boiling solvents (i.e. b.p. < 30 o C) may be problematic. High boiling solvents (b.p. >
Get Cleaning... User Guide Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Carpet Washer. vax.co.uk. Rapide Ultra series
W90-RU & W89-RU Series User Guide v1.4.qxd:user guide 2/3/11 10:03 Page 1 Carpet Washer User Guide Vax Careline: (UK) 0844 412 8455 Get Cleaning... What s your Vax model number? (Located on the top flap
PA 9117 FSAMP. Lilly. Prefilled Insulin Delivery Device User Manual
1 Lilly PA 9117 FSAMP Prefilled Insulin Delivery Device User Manual Instructions for Use Read and follow all of these instructions carefully. If you do not follow these instructions completely, you may
Dissolved Oxygen Sensors
Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit
CHEMICAL CLEANING UNIT Product number: 737189
CHEMICAL CLEANING UNIT Product number: 737189-1 - v.05/16 Content Page Intro 3 Specifications 4 Installation 5 Safety precautions 7 Maintenance 8 Spares and Accessories 8 Unitor Chemicals 9 Notes 10-2
WATER AND WASTE SYSTEMS WATER AND WASTE SYSTEMS
WATER AND WASTE SYSTEMS Table of Contents Vol. 1 21--00--1 REV 56, Jan 31/03 CHAPTER 21 --- WATER AND WASTE SYSTEMS Page TABLE OF CONTENTS 21-00 Table of Contents 21--00--1 INTRODUCTION 21-10 Introduction
FPLC standard operating procedure AKTA system (GE)
1 of 9 FPLC standard operating procedure AKTA system (GE) Note: First-time users must coordinate an introduction with Natalie (#28447) before planning their first FPLC run Before any run should commence,
240-3118 AIR CUT OFF KIT INSTALLATION INSTRUCTIONS
OPERATION MANUAL GLOBAL ELECTRONIC MIX SOLUTIONS PLURAL COMPONT MIXING SYSTEM 240-3118 AIR CUT OFF KIT INSTALLATION INSTRUCTIONS 77-3087-R1.0 (8/2015) 1 / 5 In this part sheet, the words WARNING, CAUTION
Water Tec of Tucson Water Systems
Water Tec of Tucson Water Systems Water Filter Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 1 MAIN COMPONENTS Your water treatment
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
B150 Series Commercial Brewer. Direct Plumb Kit
B150 Series Commercial Brewer Welcome Keurig Authorized Dealer! Direct Plumb Kit This manual provides: Installation of the Direct Plumb Kit (DPK) that allows you to connect your customer s B150 brewer
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
Assembly and Installation Procedures
Assembly and Installation Procedures for Pall Pharmaceutical Grade Capsule Assemblies 1. Introduction The following procedures must be followed for the installation of Pall pharmaceutical grade capsule
Pump Therapy MADE FOR YOU. Pump User Guide
Pump User Guide Pump Therapy MADE FOR YOU Dear ACCU-CHEK Spirit insulin pump owner, Thank you for choosing the ACCU-CHEK Spirit insulin pump. This guide will help you to get the most from your ACCU-CHEK
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
Novel Method for Solid Phase Peptide Synthesis Using Microwave Energy
Novel Method for Solid Phase Peptide Synthesis Using Microwave Energy Jonathan M. Collins, Michael J. Collins, Rebecca C. Steorts CEM Corporation, Matthews, NC 28106-0200, U.S.A. Presented at American
18SP653* EPA04 and EPA98 MBE 4000 High Pressure Fuel Line and Transfer Tube Installation
18SP653* EPA04 and EPA98 MBE 4000 High Pressure Fuel Line and Transfer Tube Installation * - Rev. 9/24/08 KIT DESCRIPTION A service kit (P/N: A4600700135) is now available to install EPA07 high pressure
FLUSHOMETER - TANK SYSTEM
Owner s Service Manual 501-A Series FLUSHOMETER - TANK SYSTEM 501-A Series FLUSHMATE 501-A SERIES (D) (E) (C) 2 3 (B) 1 4 (F) (A) 6 5 List of Components for 501-A Series*: 1. Lower Supply Group w/hose
Line to Refrigerator Ice/Water Dispenser
Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer
UltraClean Soil DNA Isolation Kit
PAGE 1 UltraClean Soil DNA Isolation Kit Catalog # 12800-50 50 preps New improved PCR inhibitor removal solution (IRS) included Instruction Manual (New Alternative Protocol maximizes yields) Introduction
DNA and PNA Synthesis Instruments and Consumables
Index Page DNA Synthesizers 2 Applied Biosystems Compatible Nucleic Acid Synthesis Reagents 2 Expedite System-Compatible Nucleic Acid Synthesis Reagents 12 PNA 18 Accessories 21 User Installable parts
Operating Instructions & Maintenance Guidelines for Precision Vaporizers
Operating Instructions & Maintenance Guidelines for Precision Vaporizers This page intentionally blank. Examination and Preparation for Use We want you to be completely satisfied with your vaporizer. Please
BenchPro 4100 Card Processing Station
BenchPro 4100 Card Processing Station For automated processing of routine washing and reagent incubation steps of standard laboratory procedures Catalog no. WP0001 Rev. Date: 9 September 2010 Part no.
KODAK Developer System Cleaner and Neutralizer
KODAK Developer System Cleaner and Neutralizer TECHNICAL DATA / CHEMICAL March 2010 TI-2000 GENERAL INFORMATION KODAK Developer System Cleaner and Neutralizer is designed to remove the buildup of silver
High-Throughput 3-D Chromatography Through Ion Exchange SPE
High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
ROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #
Protocol Micro Lab. K:\Microlab_protocols\Protocols_active\03 Instrument manuals\ml03_001_001 DGGE.doc. Preparation of gels
Preparation of gels Cautions: Wear gloves all times when handling acryl amide and form amide solutions and all work with acryl amide and form amide has to be done in a flow hood. Acryl amide is very toxic.
Becton-Dickinson FACSCalibur Flow Cytometer Instructions
Start-up 1. Turn on flow cytometer by pushing green button on right side of instrument, toward the back. Give it 30 minutes to warm up before collecting data. 2. Turn on monitor. 3. Turn on computer. If
STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
Installation Operation Maintenance Troubleshooting
Installation Operation Maintenance Troubleshooting Version 3, 2.1, June/09 Apr/09 1416 1402 Table of Contents Important information 2 Weights & Dimensions 3 Operator s Instructions 4 Flow Diagram 5 Purging
Artisan Thermostatic basin mixer. Fitting Instructions & Contents List
Artisan Thermostatic basin mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts 1. Introduction Thank you for choosing Bristan,
LOCAL ARRANGEMENTS FOR WASTE DISPOSAL (MAIN SITE)
LOCAL ARRANGEMENTS FOR WASTE DISPOSAL (MAIN SITE) 30 Appendix B The Chemicals Technician, Dr Mimi Nguyen, can be contacted by telephone (83337) or e-mail ([email protected]) for help or advice
Inline Chlorinator Chlorine Chemical Feeder
Inline Chlorinator Chlorine Chemical Feeder Instructions Page 1 Chlorine setting in P.P.M. for center tube and cap Hole #1 = 2 P.P.M. Hole #2 = 8 P.P.M. Hole #3 = 30 P.P.M. Hole #A = 3.5 P.P.M. Hole #B
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
Bydureon 2 mg powder and solvent for prolonged-release suspension for injection
INSTRUCTIONS FOR THE USER Your step by step guide Bydureon 2 mg powder and solvent for prolonged-release suspension for injection If you have questions about taking Bydureon Refer to the Common questions
Dipeptide Synthesis. polarized light (Figure 2).
Dipeptide Synthesis + Scheme 1: Peptide synthesis without carboxyl activation + 2 Throughout your organic chemistry tenure you have been taught the underlying principles necessary to construct simple organic
ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE
ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE Determination of total nitrogen in food and crude protein calculation (Kjeldahl method) Responsible person: Assoc.Prof. Ing.Kateřina Riddellová,
Cleaning & Sanitisation
Cleaning & Sanitisation Notice: The information and/or procedures presented in the following demonstration(s) should be performed by a trained Water Cooler Service Technician only. Never attempt to service
COMMON LABORATORY APPARATUS
COMMON LABORATORY APPARATUS Beakers are useful as a reaction container or to hold liquid or solid samples. They are also used to catch liquids from titrations and filtrates from filtering operations. Bunsen
Coating and Extraction of Honeycomb Denuders
QSM Approval: Coating and Extraction of Honeycomb Denuders 1 INTRODUCTION 1.1 The following procedures are used for the coating of honeycomb denuders with citric acid and sodium carbonate solutions, and
Standard Mixture. TOF/TOF Calibration Mixture. Calibration Mixture 1 (Cal Mix 1, 1:10) Calibration Mixture 1 (Cal Mix 1, 1:100)
Mass Standards Kit for Calibration of AB SCIEX TOF/TOF Instruments Protocol 1 Product Description The Mass Standards Kit includes reagents needed to test instrument function, optimize instrument parameters,
February 2010. Xerox 8265/8290 Color Wide Format Printer User Maintenance and Cleaning Guide
February 2010 Xerox 8265/8290 Color Wide Format Printer User Maintenance and Cleaning Guide 2010 Xerox Corporation. All rights reserved. Xerox and the sphere of connectivity design and all product names
ClikSTAR - Important facts about your new insulin delivery device.
ClikSTAR - Important facts about your new insulin delivery device. Instruction for Use ClikSTAR Insulin delivery device Before you start: Read these instructions and follow them completely each time you
Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls
Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
DIESEL FUEL CONDITIONING
COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency
1998½-2007 Dodge Ram 5.9L Cummins
9 January 2014 1081130-33 Dodge Cummins Low Fuel Pressure Alarm Light Kit (I-00143) 1 1998½-2007 Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual - Part Number Sequence: 1081130
Determination of the enthalpy of combustion using a bomb calorimeter TEC. Safety precautions
Safety precautions Naphthalene is harmful if swallowed. May cause cancer. Is further very toxic to aquatic organisms and can have long-term harmful effects in bodies of water. Equipment 1 Bomb calorimeter
Installation Instructions 6028.801
DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American
EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.
THE EXPRESS STILL This still represents the next generation in home distillation equipment. It eliminates the problem of having to spend all day processing a 25 litre wash. Taking 1 hour to heat up, then
[ Care and Use Manual ]
The Waters GPC Cleanup System uses two Envirogel GPC Cleanup Columns to perform routine cleanup of environmental samples as specified by EPA Method 3640A, GPC Cleanup. The columns, 19 x 150 mm and 19 x
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
The Electron Capture Detector (ECD)
Theory of operation The ECD is based on the phenomenon that electronegative species can react with thermal electrons present to form negatively charged ions. The loss of such electrons is related to the
Beware that ordinary prescription glasses do not provide adequate protection. This is also true with poorly fitting safety glasses.
Ethidium Bromide Introduction Ethidium bromide (EtBr) is widely used for visualization of nucleic acids in electrophoretic gels. EtBr forms fluorescent complexes, by intercalation of DNA, which are readily
Path-ID Multiplex One-Step RT-PCR Kit
USER GUIDE Path-ID Multiplex One-Step RT-PCR Kit TaqMan probe-based multiplex one-step real-time RT-PCR detection of RNA targets Catalog Numbers 4428206, 4428207, 4440022 Publication Part Number 4440907
Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual
Support Cleaning Apparatus Operation, Cleaning, & Safety Manual Revision 1.1 31 May 2014 WARNING: The instructions and precautionary statements contained herein are intended for the Support Cleaning Apparatus
AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU680 Weekly (Analyzer and ISE) Maintenance
AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance Step 1 Action Perform the Manually Clean the ISE Mix Bar, Liquid Level Sensors, Sample Pot and Sample Pot Tubing procedure AU680 Weekly (Analyzer
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
Operating Manual for Model 34988. Recovery, Recycling, Recharging Unit
Operating Manual for Model 34988 Recovery, Recycling, Recharging Unit Model 34988 Recovery, Recycling, & Recharging Unit SAFETY DEFINITIONS: Follow all WARNING, CAUTION, and NOTE messages in this manual.
SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / 8353. Instruction Manual. Page 1 of 9
SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / 8353 Instruction Manual Page 1 of 9 TABLE OF CONTENTS Introduction...3 Important Safeguards..3 System Components...5 Setup and Operation...5 Setup...5 Operation....6
Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50
Back Pack Sprayer Operator's Manual MODELS MS - 40 MS - 50 WARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood
Before installation it is important to know what parts you have and what the capabilities of these parts are.
INSTALLATION GUIDE Before installation it is important to know what parts you have and what the capabilities of these parts are. The Recon XZT is the smallest and most powerful gauge of its kind. With