HEAT FLOW BASICS. J. F. Straube
|
|
|
- Hannah Franklin
- 10 years ago
- Views:
Transcription
1 HEAT FLOW BASICS Heat flows from hot to cold. Always. Within air conditioners and heat pumps this process is manipulated to make it appear that the opposite occurs. Temperature a measure of thermal energy, units of Kelvin (K) or Celsius (C) Conductivity a material property, heat flow per unit area per unit thickness per unit temperature, symbol k (W/m K) Conductance a property of a material layer, heat flow per unit area and temperature, symbol C (W/m 2 K) = conductivity k / thickness l (in meters) Resistance a property of a material layer or wall measured from surface to surface, equals 1/C, symbol RSI (m 2 K /W) Imperial value R (ft 2 F r/btu) = RSI Overall heat transfer coefficient a property of an enclosure assembly, basically the thermal conductance of an assembly, heat flow per unit area and temperature, symbol U, U = 1/R total, units W/m 2 K. Example: Given that the thermal conductivity of Type 4 extruded polystyrene (for example, Styrofoam SM) is W/mK, find the conductance and resistance of a layer 50 mm thick in both imperial and metric units. Answer: Conductance = conductivity k / thickness l (in meters). 50 mm = m so C = / = 0.58 W / m 2 K this means, for example, that a one square meter panel of 50 mm thick Styrofoam SM will allow 0.58 watts of energy to pass through it under a one degree Kelvin (or Celsius) temperature change. Resistance, RSI = 1 / conductance, so C = 1 / 0.58 = m 2 K / W Hence, a layer of SM would have a thermal resistance of RSI If one were to look in a building supply store, a sheet of 2 SM would be stamped with RSI1.76, since 2 sheets are slightly thicker than 50 mm. By the way, a layer of 100 mm would have a thermal resistance of RSI3.45, eg twice the thickness, twice the resistance (this does not work with conductance). The thermal resistance in imperial R-value would be: Imperial value R (ft 2 F r/btu) = RSI R imp = * = R imp 9.8 Again, a full 2 thick sheet would have a slightly higher R-value of R10. Thus, one often speaks of an insulation value of R5 per inch. Four inches, R20 for this layer, 1.5, R7.5 for the layer. Most building enclosures include more than just materials they also include air spaces, which are insulating. The heat transfer from the air next to the enclosure to the surface of the enclosure is also not perfect. Hence, one needs to calculate the impact of this effect. These complications are discussed next. J. F. Straube
2 SURFACE FILMS To account for both the radiative and convective heat transfer modes at the exterior and interior surfaces of building components, the radiative and convective heat transfer coefficients are used in the form of an equivalent conductance or, alternatively, equivalent resistances. These equivalent coefficients are termed surface film coefficients. It is important to recognize that a surface film does not exist in reality. The term film is used simply so that a layer (of indefinite thickness) can be added to a typical conductive heat flow analysis. The resistance to heat flow at a surface is small relative to the heat flow resistance of most modern wall assemblies and therefore need not be accurately estimated for most purposes. Poorly insulated walls and windows have a lower overall thermal resistance and thus surface effects are more important. Hence, a more precise calculation of surface films is justified for these types of enclosures. The overall equivalent surface conductances, h o, or resistance in Table 1 can be used in to find heat flow without further modification. Again, note that surface films are fictitious: they do not physically exist, or have thickness. Surface Position Flow Direction Resistance Conductance Still Air (e.g. indoors) RSI [m 2 K/W]? [W/m 2 K]? Horizontal (i.e. ceilings Upward and floors) Downward Vertical (i.e. walls) Horizontal Moving Air (e.g. outdoors) Stormy 6.7 m/s (winter) any Breeze 3.4 m/s (summer) any Average conditions any PLANE AIR SPACES Table 1: Equivelant Total Surface Film Conductances (h o ) Plane air spaces are commonly used in building assemblies. Heat is transferred across air spaces by a combination of conduction through still air, convection flows, and by net radiation from the warm side to the cold. The modes of heat transfer vary in importance depending on: the emissivities of the surfaces, the thickness of the air space, and the absolute and relative temperatures of the two surfaces. The heat flow across a plane air space can be found with a reasonable degree of accuracy by using detailed correlations of convection and radiation. However, a high degree of accuracy is rarely necessary or justified in light of the many poorly known variables (e.g. variable cavity widths, blocked cavities, etc.) and the relatively small influence that the airspace has on the thermal resistance of modern enclosure assemblies. Simplified values for most practically encountered situations are presented in Table 2. The values in Table 2 are also given in terms of resistances so that they can be directly used in the heat flow equation. J. F. Straube UW Building Science
3 radiation T 1 T 2? 1 convection? 2 conduction s Heat Transfer Across Plane Airspaces Situation (non reflective surfaces) RSI Value Conductance Heat Flow Down ( mm) Heat Flow Across ( mm) Heat Flow Up ( mm) Table 2: Thermal Resistance for non-reflective Enclosed Airspaces (W/m 2 K) In many practical situations an air space is either intentionally or accidentally vented. Air flow through an air space can change the heat flow characteristics, although significant flows are required to modify the equivalent conductances listed above. In most cases, the effect of vented can be ignored, and only in extreme cases does in need to be accounted for. Extreme cases includes highly ventilated attics (at least 1% venting area) and wall panels with at least 2% vent area and cavities over 50 mm in size. J. F. Straube UW Building Science
4 HOW TO CALCULATE THE "R VALUE" OF AN ENCLOSURE ASSEMBLY Remember: one cannot add conductances, you must add resistances 1. List each material in the wall or roof, its conductivity (k) and its thickness (l) in m 2. Calculate the conductance of each layer (C) using C = k / l. 3. Calculate the thermal resistance of each layer using RSI = 1 / C 4. Sum the individual thermal resistances to get the answer. Usually the thermal resistance of the air films that exist on both the interior and exterior surfaces of an assembly are added to the wall as virtual layers. This makes our calculations more accurate. Example: Calculate the total thermal resistance (R) and overall heat transfer coefficient (U) of the wall shown below. Use conductivity values from tabulated values. 25 mm airspace Inside air =20?C 150 mm Concrete 75mm Type4 XPS 90mm clay brick Outside air = -10?C Answer: Layer Material Conductivity Thickness Conductance Resistance Interior film note 1 N.A. N.A Concrete Type 4 XPS Air space note 2 N.A. 25 N.A Brick Exterior film note 1 N.A. N.A RSI total 3.04 Overall Heat Transfer, U 0.33 Note 1: Table 1. Since the interior and exterior films are fictitious, they do not have a thickness, and so no conductivity. Hence, tables typically contain only conductances or resistances for the layer. These values can be quite variable, but as can be seen, the effect of the value of the film resistance on the total resistance of a wall is small if the wall is a modern insulated assembly. Note 2: Table 2. The flow of heat through an air space is complicated by convection (air flows) and radiation and so tabulated values of conductance are used instead. Like surface films, the values are variable but not important to accuracy in the calculation in most modern walls. The total resistance is RSI3.04 (or imperial R 17.2), 84%of it provided by the insulation, and heat flow will be 0.33 W/m 2 K. J. F. Straube UW Building Science
5 HOW TO CALCULATE THE STEADY-STATE HEAT FLOW THROUGH AN ENCLOSURE SYSTEM Heat flow across an assembly is simply the temperature difference divided by the R-value times the overall heat transfer coefficient. The temperature difference is usually just (t inside t outside ). 1. Find the total thermal resistance of the enclosure as described earlier 2. Find the overall heat transfer coefficient U, using U = 1/R total 3. Multiply the temperature difference across the assembly by U, i.e., U*(t inside t outside ) Of course if the sun is shining on the wall, the outdoor air temperature is not the correct one to use, (the actual solar heated surface temperature is more accurate, but difficult to find sometimes use the table provided for guidance). The effect of heat storage, or thermal mass, is very important for the wall since heavy mineral-based materials can store a lot of heat. Example: Calculate the amount of heat flow through the wall of the previous example when it -10 C outside with no sun and 20 C inside. Heat flow = U*(t inside t outside ) = 0.33 (20-10) = 0.33 (30) = 10 W/m 2 Ans. Heat flow outward would be 10 W/m 2. If the wall were exposed to bright sun, the temperature of a very dark surface would be expected to be as much as 48*1 = 48 C above the air temperature (see Table 3 later in this document). For this example, we will assume dark red brick (absorptance =0.85) and thus estimate a surface temperature of about 48 * 0.85 = 40 C above the air temperature. This means: Heat flow = U*(t inside t outside ) = 0.33 [20 -(-10+40)] = 0.33 (-10) = W/m 2 Ans. If the wall were dark red and exposed to bright sunshine, the heat flow would be inward and about 3.33 W/m 2. ASSESSING THE ENERGY LOSS DUE TO AIR LEAKAGE If cold air leaks out of the building in winter, it is of course replaced with cold/hot air. This cold/hot air must be heated up to make it comfortable. The energy impact of air leakage is significant and must be considered since it is often an important heat loss/gain component of modern buildings. It can be included by calculating an equivalent heat loss coefficient for air leakage. This can be found from: U air = 0.3 * n * V Where U air is the heat loss coefficient due to air leakage (W/ C) N is the number of complete air changes per hour ( ACH) V is the total air volume of the building (in m 3 ) U air can be included in calculations just like U wall or U window. J. F. Straube UW Building Science
6 HOW TO CALCULATE THE STEADY-STATE HEAT FLOW THROUGH A BUILDING SYSTEM The easiest means of estimating heat flow through an entire building is to 1. Calculate and then list the U-value for each element (wall, roof, window, door) along with the area of that element 2. The product of each elements' area and its U-value is the heat loss coefficient for that enclosure element per unit temperature difference (SI units: W/C) 4. The sum of these products is the overall heat loss coefficient for the building. 5. To find the overall heat loss (or gain) multiply the overall heat loss coefficient for the building by the temperature difference across the assembly. Example: An industrial "big box" store is 8 m high, 32 m long and 64 m wide. The enclosure has a lightweight roof (U=0.36 W/m 2 /C and ) and precast concrete walls (U=0.4 W/m 2 /C). The front of the store (which faces west) has a 6 m high by 24 m long glass curtainwall with a U-value of 2.0 W/m 2 /C. Six loading doors are at the back, each 5 m high and 3.5 m wide with a U-value of 1.0. The building is estimated to leak at 0.5 ACH under normal conditions. Ignoring the effect of the floors, sun, and any other doors, find the heating requirements when it is -10 C. Answer: See the sketch of the building for details of the areas. Air leakage Heat loss: 0.3 n V = 0.3 (0.50) (16384) = 2458 W/C. Enclosure Component Area (m2) U Value (W/m2/C) Q Heat Loss (W/C) % Total Heat Loss Walls % Roof % Doors % Curtain Wall % Air Leakage from above % Overall Building Heat Loss Coefficient 4103 W/C Therefore, the total heat loss can be seen to be 4103 W per degree Celsius difference. For an outdoor temperature of -10 C, indoors of 20 C, the difference is 30 C, and total heat loss is 123 kw. J. F. Straube UW Building Science
7 Building Volume =32x64x8 =16384 Roof Surface Area =32x64 =2048 m2 Curtain Wall Surface Area =24x6 =144 m2 Door Surface Area =6(3.5x5) =105 m2 Wall Surface Area =(64x8)2+(32x8)2-( ) = =1287 m2 Building Surface Area = =3584m2 The relative impact of each building component can also be seen. For this building type, the U-value of the enclosure is unimportant relative to the impact of air leakage. It should also be noted that the amount of lights and equipment and people in the store will typically consume 30 to 50 W/m 2 of electricity, all of which is converted to heat. Hence, if we assume an average energy use of 40 W/m 2, the interior gains would be: 2048 m 2 x 40 W/m 2 = W This energy will offset the losses of 123 kw, but a heating system of some type would be needed to make up the remaining (123-82) = 41 kw. J. F. Straube UW Building Science
8 SOLAR RADIATION THROUGH WINDOWS Solar gain through windows exposed to either the direct sun, or reflected sun (reflected off the particles in the sky, creating diffuse radiation or reflected off terrestrial surface, creating beam radiation) can dramatically affect the energy balance of a building. Hence, the energy flows calculated in the previous section must be adjusted by adding the solar gain through windows. This amount of energy can completely dominate the performance of a modern building. The Solar Heat Gain Coefficient (SHGC) is the window property used to rate the amount of energy allowed through windows. The SHGC is the fraction of incident solar radiation that passes through a window and becomes heat inside the building. For example, if the SHGC of a glazing unit is 0.50, and the sun is shining on the window with an intensity of 500 W/m 2, 250 W/m 2 will enter the building. The lower the SHGC, the less solar heat that the window transmits through and the greater its shading ability. In general, South facing windows in houses designed for passive solar heating (with a roof overhang to shade them in the summer) should have windows with a high SHGC to allow in beneficial solar heat gain in the winter. East or West facing windows that receive large amounts of undesirable sun in mornings and afternoons, and windows in houses in hot climates, should have a low SHGC. Most large commercial buildings should have few losses or gains through the building enclosure (this can be calculated) but windows can dramatically alter this. To calculate the impact of windows on cooling: 1. estimate the solar radiation (from charts and tables) that will be striking each building orientation during the cooling period (it is often the hottest outside when it is sunny) 2. multiply the clear area (not including mullions) of each window system on each orientation by the SHGC of that window. 3. add this energy to the energy calculated for conduction and air leakage gains. To calculate the impact of windows on heating is not as straight forward. The balance can be found for any given situation, but the coldest periods are almost always during the night, when there is no sun. Cold days, however, tend to be sunny. Therefore, simple calculations can not be used to estimate how much a furnace can be reduced in size because of solar gain. What can be calculated easily is the impact of overheating. Many solar buildings have overheating problems because of excessive areas of unshaded glass. To investigate this overheating problem, the outdoor temperature should be assumed to be the average temperature in a cool month (e.g. November or March). The maximum solar energy (usually noon with south facing glass for a solar building) should then be calculated. If the energy gain is much more than the energy loss calculated, the building will over heat. Operable shade and large amounts of ventilation will therefore be required, or the window area should be reduced. The most direct and powerful method of controlling solar gain through windows is through the use of shading and orientation. Good control requires a designer to understand the location of the sun over the day and over different orientations. Shading should be on the EXTERIOR of the glazing unit or it will trap heat in the building. With modern glazings, interior shading should primarily be used to control glare. Exterior operable shades are used through out Europe, and work remarkably well. The SHGC for good exterior shades is in the order of 0.05 to The same blinds on the interior will reduce the SHGC by about a third. J. F. Straube UW Building Science
9 Material Density (kg/m3) Conductivity Range (W/m K) Board / sheet products Plywood OSB Waferboard 0.1 Hardboard Vegetable Fiberboard Particleboard Particleboard Strawslab Corrugated Metal Deck Conductance Range (W/m2 K) negligible Finishes Ceramic Tiles 1 Acoustic Tiles - fibreboard Acoustic Tiles - glassfibre Gypsum Board Sand Plaster / Lath 0.71 Gypsum plaster / Lath Sand :Cement plaster Gypsum plaster w/perlite Gypsum plaster w/sand Carpet Fibrous Underlay 2.73 Carpet Rubber Underlay 4.42 Terrazzo 1.8 Hardwood Flooring 0.16 Siding / Cladding Hardboard siding Wood Siding - lap Plywood Siding 0.09 Face Brick - clay Face Brick - concrete Metamorphic Stone Sedimentary Stone Metal vinyl clapboard/v-groove 8 Metal - flush installed negligible Cement Stucco Structural Materials Softwood lumber Hardwood Lumber Cedar Logs and Lumber Concrete Concrete (limestone) Concrete (light) Aerated Concrete Aerated Concrete Carbon Steel Aluminum Cement Mortar Concrete Block 200 mm 5.1 Lt. Wt. Concrete Block, 200 mm 2.84 Concrete Block, 100 mm 8 Hollow tile, 100 mm 5.5 J. F. Straube UW Building Science
10 Durisol Adobe Clay Straw (function of density) Cement-bonded rice husk Wood fibre and cement Insulations EPS Type EPS Type EXPS Type 3 and Batt Insulation Rigid Mineral Fiber Rigid Fibrous Roof Insulation Rigid Polyurethane Rigid Polyisocyanurate Phenolic Foam (closed cell) Urea Formaldehyde Fibreboard Cellulose Fibre Sawdust Strawbale Corkboard Sprayed Asbestos 0.05 Vermiculite, exfoliated Perlite, expanded Perlite, expanded Perlite, bonded/expanded Eel Grass batt Jute Resin bonded Peat slab Sheeps Wool, fluffy Roof Materials Built-up Bitumen Roofing 0.17 Asphalt Shingles 12.9 Wood Shingles 6 Crushed Stone 1.60 Thatch-Straw Thatch-Reed Other Materials Fresh Snow Compacted Snow Ice at -1 and -20 C Water at 20 C Earth, dry to damp Sand dry Air, still (conduction only) Glass, soda lime Copper 380 Lead 35 Brass 120 Nickel 60 Rubber 0.2 J. F. Straube UW Building Science
11 THERMAL BRIDGES AND OTHER COMPLICATIONS One-dimensional steady-state heat flow assumptions may not allow for the accurate prediction of space-conditioning energy consumption for three main reasons: 1. Thermal Bridging: structural members (e.g., wood or steel members in light-frame construction and concrete and steel columns/walls in commercial construction) can act as a thermal bridge causing heat flow to short-circuit. Only two- or three-dimensional analysis can predict and quantify this type of heat flow. The use of insulation to break thermal bridges will effectively reduce this type of heat transfer. 2. Thermal Mass: heat flow through building enclosures is not steady-state. Heat stored in the thermal mass of buildings and then released can reduce both heating and cooling requirements. Thermal mass also makes it possible to make more effective use of internal and solar gains. Simple steady-state methods of analysis cannot model these effects. Hour-by-hour computer programs are widely available to aid in the assessment of dynamic effects. 3. Air Leakage: Air leakage through the building enclosure can be a major source of energy loss. Airtight buildings use far less energy. Again, the simple, commonly used, analysis techniques cannot assess the influence of air leakage on the thermal performance of a building system. The loss of energy by air leakage (convection) must be calculated in addition to the loss by conduction through the enclosure. Heat flow deviates from one-dimensional at corners, parapets, intersections between different assemblies, etc. When heat flows at a much higher rate through one part of an assembly than another, the term thermal bridge is used to reflect the fact that the heat has bridged over / around the thermal insulation. Thermal bridges become important when:? they cause cold spots within an assembly that might cause performance (e.g., surface condensation), durability or comfort problems? they are either large enough or intense enough (highly conductive) that they affect the total heat loss through the enclosure Thermal bridging, especially by steel framing, or at the intersection of wall corners with roofs and floors, projecting structural elements like balconies and perimeter slabs often causes cold interior surface temperatures and thus condensation. Attached figures provide a schematic of how temperatures at studs and near corners can cause low surface temperatures. In the case of the steel framing shown, an exterior temperature of 10 C can result in interior surface temperatures of 5 to 10 C at studs, and below freezing at floor to wall corners. All enclosures should be designed to avoid a large number and extreme thermal bridges. The most effective solution, insulating wall sheathings (e.g., rigid foam), are quite useful for blunting thermal bridges and also offer energy saving benefits, wind washing resistance, and improved resistance to exfiltration condensation. Convective cooling, or wind-washing, should also be controlled, especially at corners). J. F. Straube UW Building Science
12 ? t t Cold Outdoors Warm Indoors Plot of Temperature Through Wall Showing Drop At Surface Thermal bridging: heat flow Cold Exterior 10 C Siding Sheathing Batt + Framing Drywall Warm Interior +23 C Corner 20 Temp 10 0 Plot of Temperature Along wall Mid-height J. F. Straube UW Building Science
13 Thermal bridging: heat flow Cold Exterior Siding Sheathing Batt + Framing Drywall Simple R-value Through Studspace Clear Wall R-value Warm Interior Corner 2X6 FRAMED WALL Window Opening Window Opening 2X4 W/ EXTERIOR INSULATION Drywall Batt + Framing Extruded Insulation Siding Clear Wall R-value = Same as Nominal Simple R-value Thru Wall J. F. Straube UW Building Science
14 RADIATION-INDUCED EXTERIOR SURFACE TEMPERTAURES Radiation, either solar heating by the sun or cooling by radiation to the night-sky, can have a very significant influence on the thermal exposure of the building enclosure. Although rarely warranted, detailed procedures can be used to relatively accurately calculate, in terms of energy transfer rates (e.g. W/m 2 ), the effect of solar heating and night-sky cooling on enclosure surface temperatures. It is often convenient to have simple equivalent temperatures that can be entered directly into a standard conductive heat flow analysis. When an equivalent air temperature is used, the temperature is termed the sol-air temperature. This procedure has the drawback that air temperature is no longer realistic and the advantage that surface films play a role in the definition of the temperature. The value for the overall surface film coefficient is often assumed to be 17 W/m 2 ºC although this coefficient is quite variable, especially if the surface becomes hot. In fact, under solar-heating, the coefficient is likely to be as much as two times larger. A simple and equally realistic approach is to use approximate surface temperatures. Table 3 is a compilation of the most useful approximate surface temperatures based on calculation (using refined surface heat transfer coefficients) and supported by several years of field measurements. Situation Thermally Massive Thermally Lightweight Roofs: direct sun ta + 42? ta + 55? roof: sun plus reflected / emitted radiation ta + 55? ta + 72? roof exposed to night-sky ta - 5? ta - 10? walls: winter sun ta + 35? ta + 48? walls: summer sun ta + 28? ta + 40? walls exposed to night sky ta - 2? ta - 4? Notes: ta refers to the ambient air temperature,? is the surface emmittance, and? is the solar absorptance. The emmittance is about 0.90 for most materials. The absorptance varies with colour from about 0.3 for white/beige objects to 0.65 for forest green to 0.95 for flat black. Thermally massive refers to walls with a significant amount of thermal storage capacity (e.g. brick veneer or equivelant) outside of a low conductance material (e.g. insulation). Walls with significantly more mass (e.g. multi-wythe brick, rubble) or less insulation (U > 1 W/m 2 /ºC) will be less affected. Vinyl, metal and EIFS are lightweight walls; other walls can be interpolated based on heat capacity. All values are for approximately 45º North. The values for walls are likely clear night or sunny day maximums and apply to east/west orientations in summer and south orientations in the winter. Table 3: Approximate Radiation-Induced Surface Temperatures (ºC) J. F. Straube UW Building Science
Insulation R-Value Comparisons
Insulation R-Value Comparisons American Ingenuity s component panels for the 22 48 domes contains seven inch thick rigid Expanded Polystyrene (E.P.S.) insulation which has an R value of 28. American Ingenuity
R-Value and Densities Chart
R-Value and Densities Chart Material R-Value Per Inch R-Value Per Unit Inside Air Film 0.68 Air Space between Studs 0.95 Building Pa 0.06 ½ in. Fiberboard Sheathing 1.52 Gypsum Wallboard or Drywall 0.90
Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.
In Townsville s climate it is essential to choose building materials that perform well in our local conditions. Choosing the correct materials and insulation will improve the overall thermal performance
ROOFS, SNOW AND ICE DAMS
ROOFS, SNOW AND ICE DAMS The Problem Ice dams are a common roof performance problem in cold climate buildings. Simply put, they are ridges of ice and icicles caused by melt water from further up the roof
) and air spaces (R a
5.3.3 Thermal Resistance (R-value) Common thermal properties of materials and air spaces are based on steady state tests, which measure the heat that passes from the warm side to the cool side of the test
research highlight Highly Energy Efficient Building Envelope Retrofits for Houses
research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with
1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver
Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver Designing an Effective Envelope Roofs Below Grade Walls and slabs Glazing & Windows Opaque portions of walls 2 3 Energy
EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS
EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS Thermal Properties ENGR 3350 - Materials Science Dr. Nedim Vardar Copyright 2015 Thermal Properties of Materials Engage: MSEIP Engineering Everyday Engineering
Passive Solar Design and Concepts
Passive Solar Design and Concepts Daylighting 1 Passive Solar Heating Good architecture? The judicious use of south glazing coupled with appropriate shading and thermal mass. Summer Winter Passive solar
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Molds and mildew are fungi that grow
Appendix C: Moisture, Mold and Mildew Molds and mildew are fungi that grow on the surfaces of objects, within pores, and in deteriorated materials. They can cause discoloration and odor problems, deteriorate
R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E
An information series from the national authority on concrete masonry technology R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS TEK 6-2C Energy & IAQ (201) INTRODUCTION Single wythe concrete
Fire Resistance of Brick Masonry
TECHNICAL NOTES on Brick Construction 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Fire Resistance of Brick Masonry 16 March 2008 Abstract: This Technical Note presents
Performance of 8 Passive House Envelopes in Cold Climates
7 th Annual North American Passive House Conference September 27-30, 2012 Denver CO Performance of 8 Passive House Envelopes in Cold Climates Rolf Jacobson, LEED AP CSBR, University of Minnesota ZEB, Norwegian
Foundation. Foundation
Moisture Aside from structural concerns, the most important consideration for foundation design is moisture. No client wants a wet basement. No client wants a damp basement. No client wants mold in their
Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure
Basements are Changing John Straube, Ph.D., P.Eng Basements: New & Retrofit Energy Efficient, Durable, Healthy Increasingly used as living space Not a root /coal cellar anymore! High quality space expected
CHAPTER 11: PASSIVE SOLAR HOMES
Chapter 11: Passive Solar Homes 159 CHAPTER 11: PASSIVE SOLAR HOMES Passive solar homes capture both the beauty of the outside world and the heat coming in from the sun. They are designed with the local
Heating Load Calculation
Heating Load Calculation ME 425 Air Conditioning System Design Keith E. Elder, P.E. Heating Load Calculation The heating load calculation begins with the determination of heat loss through a variety of
DEFAULT HEAT LOSS COEFFICIENTS
DEFAULT HEAT LOSS COEFFICIENTS SECTION A101 GENERAL REQUIREMENTS A101.1 Scope. The following defaults shall apply to Chapter 4 of both the (RE) and (CE) sections of the IECC. This chapter includes tables
CONDENSATION IN REFRIDGERATED BUILDINGS
CONDENSATION IN REFRIDGERATED BUILDINGS By: Steve Salisbury Nov. 10, 2010 (revised Nov. 14, 2013) Introduction The following discussion reviews the basic causes of condensation in refrigerated buildings
2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.
Dow Chemical is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members.
Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls
PCA R&D Serial No. 415 Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls by John Gajda and Martha VanGeem 000 Portland Cement Association KEYWORDS Concrete,
Presented by: Jennifer Doyle, P.E., RRC, LEED AP
Presented by: Jennifer Doyle, P.E., RRC, LEED AP Moisture Gas: Molecules are spread out "Vapor" suspended in air forms a mixture, present everywhere Liquid: Molecules are closer Rain Condensation Pipes
Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi
Climate and Energy Responsive Housing in Continental Climates The Suitability of Passive Houses for Iran's Dry and Cold Climate Farshad Nasrollahi Table of Contents Abstract German Abstract Introduction
HVAC Calculations and Duct Sizing
PDH Course M199 HVAC Calculations and Duct Sizing Gary D. Beckfeld, M.S.E., P.E. 2007 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com An
R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION
An information series from the national authority on concrete masonry technology R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS TEK 6-2B Energy & IAQ (2009) INTRODUCTION Single wythe concrete
Module 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
Signs of insulation problems In the winter. In the summer. conditioning system
about your house CE 19 While previous generations may have been content to live in drafty houses, most people now want comfortable warm houses. A healthy house today is well sealed, well insulated and
THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.
THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. A Diagrammatic representation of the relationship between the
Building Envelope. Overview
Building Envelope Overview The design of the building envelope involves many considerations Both indoor and outdoor materials must be durable, resistant to vandalism, easy to maintain, and affordable They
The Case for Cross Laminated Timber: Part 2
Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction
Energy Efficiency in Buildings
Energy Efficiency in Buildings Supplemental Guide to SANS 10400-XA & SANS 204 V. 3.0 Registered to: The Drawing Studio Image: digitalart / FreeDigitalPhotos.net Report Date: 26 August 2014 Practice Name:
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
19 Examples of Wall Insulation
HUYS ADVIES 19 Examples of Insulation Technical Working Paper ~ Number 6 Thermal Insulation s for Houses in High Mountain Areas in the Himalayas Document by: Sjoerd Nienhuys Renewable Energy Advisor Date:
ECHO System for Basements
ECHO System for Basements Homeowners looking for more space are all too familiar with the cold, damp and dingy basement. Now, the Enclosure Conditioned Housing (ECHO) System TM, winner of the Ottawa-Carleton
In the Fall 2002 issue of HHE News I examined
Choosing Replacement Windows 1 For Your Home Mark Pierce In the Fall 2002 issue of HHE News I examined reasons for, and against, replacing older windows with new, energy efficient windows. That article
Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number 610.14351-R1D1. 13 January 2015
EcoPelmet Pty Ltd c/- Geoff Hesford Engineering 45 Market Street FREMANTLE WA 6160 Version: Page 2 PREPARED BY: ABN 29 001 584 612 2 Lincoln Street Lane Cove NSW 2066 Australia (PO Box 176 Lane Cove NSW
Building Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests
ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests DesignBuilder Version 1.2.0 (incorporating EnergyPlus version 1.3.0) - June 2006 1.0 Purpose The ANSI/ASHRAE Standard 140-2004
HIGH PERFORMANCE BUILDING ENVELOPES. Dave Seifert
Dave Seifert Design Construction Commissioning PRESENTATION OVERVIEW About BCRA How Did We Get Here? What is a High Performance Building Envelope? Energy Conservation Considerations Durability Considerations
Rockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
Diego Ibarra Christoph Reinhart Harvard Graduate School of Design
Building Performance Simulation for Designers - Energy DesignBuilder // EnergyPlus Tutorial #2 Load Schedules GEOMETRY LOADS RESULTS Diego Ibarra Christoph Reinhart Harvard Graduate School of Design OVERVIEW
Selecting Energy-Efficient Windows
Selecting Energy-Efficient Windows E N E R I N F O A D V I S O R S E R I E S Key Points Improving the energy performance of windows is important, since windows are the least insulated surface of most homes.
Energy efficient home design
Energy efficient home design GUIDELINES How an energy efficient home can help you live in comfort and save money An energy efficient home is designed to provide shade and allow cooling breezes to enter
The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A
TechSpecs A builder s blueprint for construction technologies January 2013 The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A C B A E D H G F A. Wood Floor Framing - p. 2 B. Foundation
B. Related categories: The following categories contain requirements that relate to this section:
ORIENTED STRAND BOARD PART I. - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
Housing Fact Sheets. Insulation Check-Up
Insulation Check-Up Housing Fact Sheets Introduction Heating and cooling account for the majority of energy costs in homes throughout the United States. Although current energy prices are relatively low,
Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature
Thermal Values Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature relative to changing exterior temperatures. By reducing interior temperature
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS
HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS HIGH-QUALITY INSULATION. SUSTAINABLE LIVING. www.homatherm.com Preamble THE EXAMPLE OF NATURE Sustainable living to us means harnessing the forces of
Renovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
Heating and cooling. Insulation. Quick facts on insulation:
Heating and cooling Heating and cooling your home can be one of the biggest users of energy. Efficency in this area can bring great savings. Heating and cooling depend on many contributing factors. The
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating
Detached accessory structures that contain no conditioned floor area are exempt.
RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of
Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses
Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film
Article Protecting the Building Envelope from Water Damage Vapor Retarders Play a Crucial Role in Moisture Management Whether we like it or not, moisture in the form of water vapor diffusion and humid
Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows
Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows Marc LaFrance Technology Development Manager US Department of Energy Building Technology Program
Selecting Energy Efficient New Windows in Georgia
Selecting Energy Efficient New Windows in Georgia www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.
Adaptive strategies for office spaces in the UK climate
International Conference Passive and Low Energy Cooling 631 Adaptive strategies for office spaces in the UK climate I. Gallou Environment & Energy Studies Programme, Architectural Association Graduate
Preventing Ice Dams on Roofs
Preventing Ice Dams on Roofs Facility Manager November/December 2005 When a roof leaks, facility managers inevitably receive complaints from building occupants. If it is winter, ice dams are often the
Underwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
Solar Aquaponics Designing a 100% Solar Aquaponics Greenhouse
Solar Aquaponics Designing a 100% Solar Aquaponics Greenhouse Dan Chiras, Ph.D. Director, The Evergreen Institute Gerald, MO 63037 www.evergreeninstitute.org Topics Creating a 100% solar operation Efficiency
Chapter 4: Transfer of Thermal Energy
Chapter 4: Transfer of Thermal Energy Goals of Period 4 Section 4.1: To define temperature and thermal energy Section 4.2: To discuss three methods of thermal energy transfer. Section 4.3: To describe
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS The LOGIX wall assembly has no need for an additional vapor barrier, the solid concrete core covered with the low permeance EPS (Type II) foam
Selecting Energy Efficient New Windows in Arizona
Selecting Energy Efficient New Windows in Arizona www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.
C-2 Construction, Inc. - NAICS Codes
C-2 Construction, Inc. - NAICS Codes 212313 - Crushed and Broken Granite Mining and Quarrying This U.S. industry comprises: (1) establishments primarily engaged in developing the mine site, and/or mining
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
Selecting Energy Efficient Replacement Windows in Nevada
Selecting Energy Efficient Replacement Windows in Nevada www.efficientwindows.org January 06 STAR Zones. Meet the Energy Code & Look for the STAR Windows must comply with your local energy code. Windows
Infrared Moisture Detection
What it can do for you... what it can t and why 1. Infrared camera basics 2. Examples Lew Harriman MoistureDM.com 3. Summary - The 4 most important facts about infrared moisture detection 1 of 19 Infrared
Multi-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
A Kingspan Summary of a Building Science Corporation Report
Insulated Panels REVIEW & ANALYSIS OF EXTERIOR WALL ASSEMBLY PERFORMANCE A Kingspan Summary of a Building Science Corporation Report REVIEW & ANALYSIS OF EXTERIOR WALL ASSEMBLY PERFORMANCE Exterior Wall
What you need to know about concrete block basement construction.
Designing and planning your new residence is a vitally important process, which will have a great influence on the future enjoyment of your home. A successful process will ensure all areas of the home
Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:
PASSIVE Solar Design Solar Homes Catch the Sun Are you planning a new house? Discover how you can apply solar architecture principles to: keep your heating bills to a minimum enjoy the comfort of a warm
HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS
HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS Saim Memon Philip C. Eames Centre for Renewable Energy Systems
Moisture-Safe Unvented Wood Roof Systems
building science.com 2010 Building Science Press All rights of reproduction in any form reserved. Moisture-Safe Unvented Wood Roof Systems Research Report - 1001 April-2010 John Straube, Jonathan Smegal
If you are a web registered user of ArlingontPermits.com you may also request an inspection at:
TECHNICAL BULLETIN Community Development & Planning, Building Inspections TOPIC: Permits & Inspections for Roofing Replacement Effective November 1, 2011 Revised This Technical Bulletin will provide contractors
Field Performance of Different Interior Basement Insulation Systems
Field Performance of Different Interior Basement Insulation Systems Marc Zuluaga Robb Aldrich Dianne Griffiths, P.E. Associate Member ASHRAE ABSTRACT With the support of the Department of Energy s Building
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
Case Study Family Room Renovation 3br family home, Melbourne
Family Room Renovation 3br family home, Melbourne In a Nutshell With time and budget constraints we often renovate just one room at a time. This case study looks at a family room renovation where the key
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
ENERGY AUDIT. Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM):
ENERGY AUDIT Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM): Leonard Fernandes DERBIGUM project reference : UAE -2014 - EA 103 Author : Daniel Heffinck (DERBIGUM)
Everybody talks about the high
An Efficient Wall System Produces Energy Savings and Attractiveness Florida Man Designs Own Home Complete With Patented Air- Return System Plus Insulated Roof and Stucco Wall System Everybody talks about
The Optimum Basement Wall
The Optimum Basement Wall Solutions to the Wet Blanket Basement Problem February 27 th, 2014 1 Adapting to Change! We ve made significant advances in water management. Customers no longer accept that musty
Built to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
Constructions Database User Guide <Virtual Environment> 5.9
Constructions Database User Guide 5.9 Page 1 of 35 Contents 1. Introduction...3 2. Units...4 3. Main Dialogue Project Constructions...5 3.1. Outline...5 3.2. Construction Classes