Test reports Approvals. Test reports/ Approvals
|
|
|
- Bruno Chapman
- 10 years ago
- Views:
Transcription
1 Test reports Approvals Test reports/ Approvals
2
3 04-034/01 VANDEX BB 75 Drinking Water Inspectorate, London 2005 Great Britain DWI - Approval /01 VANDEX BB 75 Hygiene Institute of the University of Bonn Slime formation /01 VANDEX BB 75 Hygiene Institute of the Ruhrgebiet, Gelsenkirchen /01 VANDEX BB 75 British Board of Agreement 2004 Great Britain BBA - Approval /04 VANDEX BB 75 Water Regulation Advisory Scheme, Oakdale, Gwent, UK 2002 Great Britain WRAS - Approval /00 VANDEX BB 75 PSB Corporation Pte Ltd., Singapore 2002 Singapore Toxic metals Leaching test Cytotoxicity /00 VANDEX BB 75 Laboratoire d'hygiene et de Recherche en Santé Publique, Nancy 2001 France /00 VANDEX BB 75 Material Research and Test Institute for Buildings Leipzig e.v. Selfsealing capacity BS 6920 BS 6920:2000 NF XP P , -2 et -3, Circulaire DGS/VS4 n DIN /00 VANDEX BB 75 Official Materials Clausthal- µco2 - diffusion /00 VANDEX BB 75 Hygiene Institute of the Ruhrgebiet, Gelsenkirchen 1993 Germany KTW - Test TOC Organoleptic test Free chlorine 1 VXITRE0205
4 01-007/03 VANDEX BB 75 Official Materials Clausthal Germany µh2o - diffusion Shrinkage /00 VANDEX BB 75 Official Materials Clausthal Germany Modulus of elasticity /00 VANDEX BB 75 Ambric Testing Inc., Philadelphia 1992 United States of America /00 VANDEX BB 75 Official Materials Clausthal Germany US Corps of Engineers CRD C 48 DIN /00 VANDEX BB 75 Centre de Recherche et de Controle, des Eaux, Paris 1987 France Ozone resistance /00 VANDEX BB 75 E Taywood Engineering Ltd. Research Laboratories, Southall 1995 Great Britain Crack bridging capacity /00 VANDEX BB 75 E Official Materials Clausthal Germany /01 VANDEX BB 75 E Official Materials Clausthal Germany µh2o - diffusion Tensile strength Crack bridging capacity DIN 1048 DIN /00 VANDEX BB 75 E CEBTP, Centre Expérimental de Recherches et, d'etudes du Bâtiment et des Travaux Publics 1990 France Wear resistance Abrasion resistance /00 VANDEX BB 75 E University of Dortmund 1987 Germany µco2 - diffusion 2 VXITRE0205
5 01-082/01 VANDEX BB 75 Z Hygiene Institute of the University of Bonn Slime formation /01 VANDEX BB 75 Z Hygiene Institute of the Ruhrgebiet, Gelsenkirchen /01 VANDEX BB 75 Z LPM AG, Laboratory for Testing and Material 2001 Switzerland Sulphate resistance Chemical resistance ASTM C /11 VANDEX BB 75 Z LPM AG, Laboratory for Testing and Material 1997 Switzerland Shrinkage Resistance against sewage /01 VANDEX BB 75 Z Official Materials Clausthal- Modulus of elasticity /00 VANDEX BB WHITE Drinking Water Inspectorate, London 2005 Great Britain DWI - Approval /01 VANDEX BB WHITE Hygiene Institute of the University of Bonn Slime formation /03 VANDEX BB WHITE WRc Evaluation & Testing Centre Ltd., Oakdale, Gwent 2001 Great Britain WRAS - Approval /01 VANDEX CEMELAST Hygiene Institute of the Ruhrgebiet, Gelsenkirchen /00 VANDEX CEMELAST Hygiene Institute of the Ruhrgebiet, Gelsenkirchen 2002 Germany DIN EN BS VXITRE0205
6 09-046/00 VANDEX CEMELAST Australian Water Quality Centre, Bolivar, South Australia 2001 Australia Organoleptic test Cytotoxicity Mutagenic activity /00 VANDEX CEMELAST Hygiene Institute of the Ruhrgebiet, Gelsenkirchen 1999 Germany KTW - Test Free chlorine /00 VANDEX CEMELAST Official Materials Clausthal Germany µh2o - diffusion Crack bridging capacity AS/NZS 4020:1999 KTW-Test DIN 53455, DIN 52615, DIN , DIN ISO /00 VANDEX CEMELAST Official Materials Clausthal Germany µco2 - diffusion /00 VANDEX CEMELAST LIQUID Laboratoire d'hygiene et de Recherche en Santé Publique, Nancy 1999 France /01 VANDEX CEMLINE MORTAR Hygiene Institute of the Ruhrgebiet, Gelsenkirchen /00 VANDEX CEMLINE MORTAR Official Materials Clausthal- Modulus of elasticity /01 VANDEX CEMLINE TOP Hygiene Institute of the Ruhrgebiet, Gelsenkirchen GREY /00 VANDEX CEMLINE TOP Official Materials Clausthal- GREY Modulus of elasticity DIN EN DIN / DIN EN 196 Part 1 4 VXITRE0205
7 01-088/01 VANDEX CEMLINE TOP Hygiene Institute of the Ruhrgebiet, Gelsenkirchen WHITE /00 VANDEX CEMLINE TOP Official Materials Clausthal- WHITE Modulus of elasticity /00 VANDEX CONCRETE GREY Drinking Water Inspectorate, London 2005 Great Britain DWI - Approval /03 VANDEX CONCRETE GREY WRc Evaluation & Testing Centre Ltd., Oakdale, Gwent 2001 Great Britain WRAS - Approval DIN EN 196-1, DIN /50-2 BS /01 VANDEX CONSTRUCTION Material Research and Test Institute for Buildings JOINT TAPE Leipzig e.v Germany Crack bridging capacity Performance /01 VANDEX CORROSION Hygiene Institute of the University of Bonn PROTECTION M Slime formation /00 VANDEX CORROSION Official Materials Clausthal- PROTECTION M Corrosion test Corrosion behaviour of Vandex treated steel /00 VANDEX CRS LEVELLING Official Materials Clausthal- COMPOUND LC 2002 Germany Modulus of elasticity /00 VANDEX CRS OS 95 Swedish National Testing and Research Institute 2000 Sweden Chloride pentration µco2 - diffusion TL BE-PCC, 7.13, ZTV-SIB 90 (DIN 50017) EN NT BUILD 372, APM 401 (NT BUILD 489) 5 VXITRE0205
8 01-032/01 VANDEX CRS OS 95 Official Materials Clausthal Germany µh2o - diffusion Crack bridging capacity µco2 - diffusion /00 VANDEX CRS REPAIR Official Materials Clausthal- MORTAR Germany Modulus of elasticity ZTV SIB 90 TL/TP OS EN /00 VANDEX CRS REPAIR LPM AG, Laboratory for Testing and Material MORTAR Switzerland Frost resistance Thaw-salt resistance /00 VANDEX CRS REPAIR Official Materials Clausthal- MORTAR HB 2002 Germany Modulus of elasticity EN /00 VANDEX DPC INJECTION Official Materials Clausthal- NO Germany /01 VANDEX EXPASEAL 2520 Prof.Dr.Th.Mang, Laboratory for macromolecular chemistry and polymer technology 1998 Germany Chemical resistance /00 VANDEX EXPASEAL 2520 Studiengesellschaft für unterirdische Verkehrsanlagen e.v. STUVA 1990 Germany /00 VANDEX EXPASEAL 2520 Hygiene Institute of the Ruhrgebiet, Gelsenkirchen 1989 Germany KTW - Test /01 VANDEX LEVELLING Institute of Construction Materials Technical PLASTER University of Munich 1994 Germany µh2o - diffusion TOC /01 VANDEX MINERALIT Drinking Water Inspectorate, London 2005 Great Britain KTW-Test WTA Guideline VXITRE0205
9 01-019/01 VANDEX MINERALIT Hygiene Institute of the University of Bonn Slime formation /02 VANDEX MINERALIT Hygiene Institute of the Ruhrgebiet, Gelsenkirchen /00 VANDEX PLUG Drinking Water Inspectorate, London 2005 Great Britain DWI - Approval /04 VANDEX PLUG WRc Evaluation & Testing Centre Ltd., Oakdale, Gwent 2002 Great Britain WRAS - Approval /01 VANDEX POLYCEM Z BBL Basler Baulabor AG 2003 Switzerland Resistance against sewage Sulphate resistance Chemical resistance Biogenic sulfuric acid attack /00 VANDEX POLYCEM Z LPM AG, Laboratory for Testing and Material 2002 Switzerland Sulphate resistance Chemical resistance /00 VANDEX POLYCEM Z LPM AG, Laboratory for Testing and Material 2001 Switzerland Frost resistance Thaw-salt resistance /00 VANDEX POLYCEM Z Official Materials Clausthal Germany Shrinkage /00 VANDEX PREMIX Drinking Water Inspectorate, London 2005 Great Britain DWI - Approval BS 6920 ZTV SIB 90, DIN 38405, DIN ASTM C 1012 SN , ASTM C DIN EN 196-1,DIN , DIN , DIN ISO VXITRE0205
10 04-044/00 VANDEX PREMIX British Board of Agreement 2004 Great Britain BBA - Approval Sulphate resistance Performance /04 VANDEX PREMIX WRc Evaluation & Testing Centre Ltd., Oakdale, Gwent 2002 Great Britain WRAS - Approval /00 VANDEX QUICKBINDER Thames Water, London 1984 Great Britain Toxic metals Organoleptic test Cytotoxicity /01 VANDEX REFURBISHMENT Institute of Construction Materials Technical PLASTER white University of Munich 1994 Germany µh2o - diffusion /01 VANDEX ROUGH CAST Institute of Construction Materials Technical University of Munich 1994 Germany µh2o - diffusion Diff. BS 6920 BS 6920 WTA Guideline WTA Guideline /00 VANDEX SEALER AC Technological Institute, Taastrup 1985 Denmark /00 VANDEX SEALER AC Technological Institute, Taastrup 1985 Denmark /00 VANDEX SEALER AC Technological Institute, Taastrup 1985 Denmark µh2o - diffusion µco2 - diffusion /00 VANDEX SUPER Drinking Water Inspectorate, London 2005 Great Britain DWI - Approval /00 VANDEX SUPER British Board of Agreement 2004 Great Britain BBA - Approval Sulphate resistance Performance Diff. 8 VXITRE0205
11 05-014/09 VANDEX SUPER National Sanitation Foundation 2003 United States of America NSF-Approval /00 VANDEX SUPER Australian Water Quality Centre, Bolivar, South Australia 2002 Australia Organoleptic test /00 VANDEX SUPER PSB Corporation Pte Ltd., Singapore 2002 Singapore Toxic metals WRC - Approval Leaching test Cytotoxicity /04 VANDEX SUPER WRc Evaluation & Testing Centre Ltd., Oakdale, Gwent 2002 Great Britain WRAS - Approval NSF Standard 61 AS/NZS 4020:1999 BS 6920:2000 BS /00 VANDEX SUPER Tokyo Institute of Technology Architectural Physics Research Center 2000 Japan Compatibility of VX SUPER and epoxy /00 VANDEX SUPER Ambric Testing Inc., Philadelphia 1990 United States of America US Corps of Engineers CRD D /00 VANDEX SUPER Taywood Engineering Ltd. Research Laboratories, Southall 1985 Great Britain Corrosion test Chloride pentration /00 VANDEX SUPER CEBTP, Centre Expérimental de Recherches et, d'etudes du Bâtiment et des Travaux Publics 1983 France Wear resistance Abrasion resistance /00 VANDEX SUPER Taylor Woodrow Laboratories, Southall 1981 Great Britain Water permeability /00 VANDEX SUPER Jydsk Teknologisk Institut 1980 Denmark DIN /00 VANDEX SUPER New Haven Testing Laboratory, Inc., New Haven, Connecticut 1977 United States of America Shear test 9 VXITRE0205
12 05-007/00 VANDEX SUPER Pacific Testing Laboratories 1976 United States of America µh2o - diffusion ASTM C /00 VANDEX SUPER Radiation Technology, Inc., New Jersey 1976 United States of America Resistance against radiation Radiation test /00 VANDEX SUPER Lucius Pitkin Analytical Metallurgical and Research Laboratories 1975 United States of America Corrosion test Corrosion behaviour of Vandex treated steel /00 VANDEX SUPER Gordon Spratt & Associates Ltd., Vancouver 1973 Canada Sulphate resistance /00 VANDEX SUPER The Ship Research Institute 1969 Norway Compatibility of VX SUPER and epoxy Salt diffusion /00 VANDEX SUPER WHITE British Board of Agreement 2004 Great Britain BBA - Approval Sulphate resistance Performance Diff /00 VANDEX SUPER/PREMIX CEBTP, Centre Expérimental de Recherches et, d'etudes du Bâtiment et des Travaux Publics 1982 France Water permeability /00 VANDEX SUPER/PREMIX CEBTP, Centre Expérimental de Recherches et, d'etudes du Bâtiment et des Travaux Publics 1982 France Water permeability /00 VANDEX SUPER/PREMIX Ministry of Public works, Shuwaikh 1976 Kuwait Climatic test Weatherometer test /00 VANDEX SUPER/PREMIX University of Tokyo, Technical Division 1967 Japan Penetration depth /00 VANDEX SUPER/PREMIX Lime and Brick Laboratory, Aarhus 1967 Denmark µh2o - diffusion Water permeability /01 VANDEX UNI MORTAR 1 Drinking Water Inspectorate, London 2005 Great Britain DWI - Approval 10 VXITRE0205
13 01-020/01 VANDEX UNI MORTAR 1 Hygiene Institute of the University of Bonn Slime formation /04 VANDEX UNI MORTAR 1 WRc Evaluation & Testing Centre Ltd., Oakdale, Gwent 2002 Great Britain WRAS - Approval /00 VANDEX UNI MORTAR 1 Official Materials Clausthal Germany µh2o - diffusion µco2 - diffusion /00 VANDEX UNI MORTAR 1 Official Materials Clausthal Germany Shrinkage /00 VANDEX UNI MORTAR 1 LPM AG, Laboratory for Testing and Material 1987 Switzerland Frost resistance Thaw-salt resistance /01 VANDEX UNI MORTAR 1 Z Hygiene Institute of the Ruhrgebiet, Gelsenkirchen /00 VANDEX UNI MORTAR 1 Z Australian Water Quality Centre, Bolivar, South Australia 2002 Australia Organoleptic test Cytotoxicity Mutagenic activity BS6920 DIN DIN ;DIN 42450;DIN 1048 SN ; ASTM C AS/NZS 4020: /21 VANDEX UNI MORTAR 1 Z LPM AG, Laboratory for Testing and Material 1997 Switzerland Shrinkage Resistance against sewage /02 VANDEX UNI MORTAR 1 Z Official Materials Clausthal- DIN EN VXITRE0205
14 01-058/03 VANDEX UNI MORTAR 1 Z Official Materials Clausthal /00 VANDEX UNI MORTAR 1 Z LPM AG, Laboratory for Testing and Material 1995 Switzerland Abrasion resistance /02 VANDEX UNI MORTAR 2 Ambric Testing Inc., Philadelphia 1990 United States of America Tensile strength Shrinkage Abrasion resistance DIN 1048 DIN ASTM C109, C 348, C 321, C 596, C /00 VANDEX UNI MORTAR 2 State Materials Testing Center Darmstadt 1969 Germany Shrinkage 12 VXITRE0205
Krystol Internal Membrane (KIM )
1of 6 Krystol Internal Membrane (KIM ) (Waterproofing Admixture for Concrete) DESCRIPTION Krystol Internal Membrane (KIM) is a hydrophilic crystalline waterproofing admixture in dry powder form. KIM is
Concrete Repair. Applications and Procedures
Concrete Repair Applications and Procedures Objectives Identify what surface preparation is needed Identify typical modes of failure and testing methods How to choose the correct material for the repair
NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE
NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE What is negative side waterproofing? A typical case of negative side waterproofing is when water comes through the walls of a basement and the
SPECIAL COMPOUND FOR RHEOPLASTIC AND ANTI-CORROSION SUPERCONCRETE WITH VERY HIGH DURABILITY
BS 40 M6 MuCis mono SPECIAL COMPOUND FOR RHEOPLASTIC AND ANTI-CORROSION SUPERCONCRETE WITH VERY HIGH DURABILITY LE CE LE type: "expansive binder which allows the production of extremely fluid concrete
MANDATORY PROVIDENT FUND SCHEMES AUTHORITY
Guidelines III.4 MANDATORY PROVIDENT FUND SCHEMES AUTHORITY III.4 Guidelines on Approved Exchanges INTRODUCTION Section 2 of the Mandatory Provident Fund Schemes (General) Regulation ( the Regulation )
Sika FerroGard -903 + The Unique Multi-Functional Surface Applied Corrosion Inhibitor for Reinforced Concrete. Innovation & Consistency.
FerroGard -903 + The Unique Multi-Functional Surface Applied Corrosion Inhibitor for Reinforced Concrete Innovation & Consistency since 1910 Corrosion in Reinforced Concrete Structures Aggressive Influences
www.fosroc.com Concrete repair and remediation to BS EN 1504 constructive solutions
www.fosroc.com constructive solutions repair and remediation to BS EN 1504 Fosroc Limited Drayton Manor Business Park Coleshill Road Tamworth Staffordshire B78 3TL United Kingdom Tel: +44 (0) 1827 262222
OVERVIEW. 1 Intent:... 2. 2 Applicability:... 2. 3 Referenced Standards... 2. 5 Invert Repair Mortar... 3
PERMACAST CENTRIFUGALLY CAST CONCRETE PIPE (CCCP) OVERVIEW 1 Intent:... 2 2 Applicability:... 2 3 Referenced Standards... 2 5 Invert Repair Mortar... 3 6 Centrifugally Cast Concrete Pipe (CCCP)... 3 7
DURABILITY OF MORTAR LININGS IN DUCTILE IRON PIPES Durability of mortar linings
DURABILITY OF MORTAR LININGS IN DUCTILE IRON PIPES Durability of mortar linings I. S. MELAND SINTEF Civil and Environmental Engineering, Cement and Concrete, Trondheim, Norway Durability of Building Materials
Silane Penetrating Waterproofing Treatments AND Changing VOC Regulations Presented By: Jerry Fulcher Advanced Chemical Technologies, Inc.
Silane Penetrating Waterproofing Treatments AND Changing VOC Regulations Presented By: Jerry Fulcher Advanced Chemical Technologies, Inc. Penetrants Forms chemical bond with the walls of the pores, the
MCI QUESTIONS & ANSWERS
MCI QUESTIONS & ANSWERS Q. Are Migrating Corrosion Inhibitors (MCI) similar to Vapor phase Corrosion Inhibitors (VpCI)? A. MCI technologies are chemically similar to VpCI. The protection mechanism is identical.
The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.
QUALITY INSIDE When it comes to long life piping for drinking water, sewage, industrial water or gas, there is one name that continues to lead the way - ECOPUR by vonroll. Delivering precision-engineered
EVALUATION OF THE PERFORMANCE OF THE PROTECTIVE SURFACE COATINGS FOR CONCRETE
EVALUATION OF THE PERFORMANCE OF THE PROTECTIVE SFE COATINGS FOR CONCRETE Haimoon CHEONG * Hwangu YU *2 Taesong AHN *3 Byunghwan OH *4 ABSTRT: Chloride penetration into concrete is the main cause of the
How To Test A Wrap N Drain X Dampproofing System
National Research Council Canada Institute for Research in Construction Conseil national de recherches Canada Institut de recherche en construction CCMC 13094-R &&0& EVALUATION DIVISION 07111 REPORT Issued
Concrete Waterproofing by Crystallization. General Construction Foundations
Concrete Waterproofing by Crystallization General Construction Foundations The Structures The Problems Xypex products play a key role in the waterproofing of concrete against water leakage, even against
MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES
Liquid Coating Properties Composition VOC Content, ASTM D2369 Water Content, ASTM D4017 Physical Properties Calculating Physical Constants of Coatings, ASTM D5201 Density, ASTM D1475 Flash Point, ASTM
www.pitchmasticpmb.com PmB Expansion Joints World leaders in expansion joint technology
www.pitchmasticpmb.com Expansion Joints World leaders in expansion joint technology High performance expansion joint solutions Pitchmastic offers a comprehensive range of specialist services to the civil
CONSTRUCTION MATERIAL TESTING WWW.AU.SGS.COM/INDUSTRIAL
CONSTRUCTION MATERIAL TESTING WWW.AU.SGS.COM/INDUSTRIAL Introduction For over 20 years, we have offered a full range of materials testing to suit the requirements of local, national and international civil
How To Determine The Effect Of Frost Deterioration On Chloride Penetration And Carbonation
This document is downloaded from the Digital Open Access Repository of VTT Title Effect of concrete frost deterioration on chloride penetration and carbonation Author(s) Kuosa, Hannele; Leivo, Markku;
Polyurea Coatings in Secondary Containment with National Technical Approval. Jürgen Magner Kiwa Polymer Institut Flörsheim / Germany
Polyurea Coatings in Secondary Containment with National Technical Approval Jürgen Magner Kiwa Polymer Institut Flörsheim / Germany concrete substrate high rack tanks organic coating secondary containment
TABLE OF CONTENTS CHAPTER NO. TITLE PAGE NO. ABSTRACT
vii TABLE OF CONTENTS CHAPTER NO. TITLE PAGE NO. ABSTRACT LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS AND ABBREVIATIONS iii xvii xix xxvii 1 INTRODUCTION 1 1.1 GENERAL 1 1.2 OBJECTIVES AND SCOPE OF
Special Linings for unusual service conditions. Please contact ACIPCO.
Linings Linings Along with technical and metallurgical advancement in piping materials, research on lining requirements for pipe and fittings has resulted in the development of linings to meet many different
1) Cement, cementitious products and the drinking water infrastructure
MPA Cement Fact Sheet 19 Cement, cementitious products and drinking water Introduction Cement 1 is used widely in construction works, including in the UK's drinking water infrastructure. Concrete and pipe-lining
THORO. Waterproofing Systems
THORO Waterproofing Systems Contents Welcome to the world of Thoro 3 Waterproofing 4 Thoroseal 5 Thoroseal FC 6 Thoro Acryl 60 6 Thoroseal WR 7 Thoroseal FX100 8 Thoroseal FX110 9 Thoroseal FX 1K 10 Thoro
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests
Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages
CREATING TOMORROW S SOLUTIONS
CREATING TOMORROW S SOLUTIONS Concrete Protection for Concrete Advantages 1 cost savings and environmental compatibility through innovative technology 2 Contents Prevention rather than renovation 2 Concrete:
Physically Crosslinked Foam Insulation
Physically Crosslinked Foam Insulation Thermobreak is the original All in One flexible thermal insulation made from physically crosslinked closed cell polyolefin foam, factory fused to a reinforced 9um
SITE INVESTIGATION FACILITIES
SITE INVESTIGATION FACILITIES Drilling Hydraulic rotary & calax drilling rigs100/150mm Diameter boreholes having drilling capacity up to 200m depth. Auger drilling 100/150mm diameter boreholes up to maximum
The Concrete Life Cycle: Maintain to Sustain. Fred Goodwin BASF Construction Chemicals (EB-N) Beachwood OH
The Concrete Life Cycle: Maintain to Sustain Fred Goodwin BASF Construction Chemicals (EB-N) Beachwood OH What is Concrete? Concrete: Instant rock -just add water to make a hard wet sponge. A composite
Concrete Waterproofing Systems. Integral Protection. www.tritonsystems.co.uk
Concrete Waterproofing Systems Integral Protection n Type B Integral Protection in accordance with BS 8102 (2009) n Unique chemical admix for waterproofing and protection of concrete n A complete and permanent
Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer
SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES
1.00 PART 1 GENERAL 1.01 SCOPE A. It is the intent of this contract to install a 100% solids epoxy monolithic coating to the walls, benches and inverts of all manholes and the specified surfaces of other
Integrated Manhole Ladder System
Application: This innovative product has been designed to provide safe access and egress to precast concrete manholes and inspection chambers. It can also be used within any other underground concrete
Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)
Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.) Gyproc Plasters The cracks in cement sand plaster are an inherent feature which cannot be completely prevented but can only be controlled and
Comprehensive safety concepts for building applications
Comprehensive safety concepts for building applications Preventive fire protection Experience, know-how, competence, quality and safety pyrofil for safety Fire reaction Dätwyler is the first european manufacturer
Plastics Engineering SYSTEM BEKAPLAST. Mechanically anchored thermoplastic lining for extreme conditions
Plastics Engineering SYSTEM BEKAPLAST Mechanically anchored thermoplastic lining for extreme conditions Beka_Gesamt_en 2014.indd 1 System BEKAPLAST Mechanically anchored lining systems to meet the highest
100 Year Service Life of Polypropylene And Polyethylene Gravity Sewer Pipes. Summary Technical Report
December 2014 100 Year Service Life of Polypropylene And Polyethylene Gravity Sewer Pipes A TEPPFA Project in cooperation with Borealis and LyondellBasell Summary Technical Report (Based on Extracts of
2009-12-23 ICS: 93.160. Strengthening retrofitting of reinforced concrete structures by gluing of fibre reinforced polymeric fabrics (FRP fabrics)
36888 ежглеяис тгс йубеямгсеыс (теувос еутеяо) 20091223 ICS: 93160 150114010801:2009 H HELLENIC CHNICAL SPECIFICATION (FRP ) Strengthening retrofitting of reinforced concrete structures by gluing of fibre
SULPHATE ATTACK AND CHLORIDE ION PENETRATION: THEIR ROLE IN CONCRETE DURABILITY
SULPHATE ATTACK AND CHLORIDE ION PENETRATION: THEIR ROLE IN CONCRETE DURABILITY Concrete durability continues to be a subject of controversy among design professionals, specifiers, Government instrumentalities,
MULTI-TIGHT 2K. The New Generation for Waterproofing Buildings
MULTI-TIGHT 2K The New Generation for Waterproofing Buildings MULTI-TIGHT 2K Properties: One Product for all Cases Functional Use for New Construction and Refurbishment Quick drying Adheres to many substrates
LuxeMbOurG Trading CenTre LisT Annex 1 to the s pecial terms and conditions for securities transactions Valid as from 1 January 2011
Luxembourg Annex 1 to the Special terms and conditions for securities transactions Valid as from 1 January 2011 In order to achieve the best possible result in executing security orders, the bank has selected
Structural Testing of GeoPolymer Pipe/Culvert Lining
Structural Testing of GeoPolymer Pipe/Culvert Lining Joseph Royer, Ph.D. October 27 th, 2015 What is a GeoPolymer? Not a Plastic Not HDPE/PVC/Epoxy Looks and feels like cement Workability Material Properties
Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA 18000 / Israel. J. Magner Dipl.-Ing. N. Machill.
Kiwa Polymer Institut GmbH Quellenstraße 3 65439 Flörsheim-Wicker Tel. +49 (0)61 45-5 97 10 Fax +49 (0)61 45-5 97 19 www.kiwa.de Test report P 7013-E Testing order: Test of the waterproofing system based
up (Penetron sandwich system ) restraint causes tensile stresses that exceed the placed concrete s tensile strength, thermal Figure 2 Example of plastic shrinkage cracks Figure 3 Example of drying shrinkage
Technical. Specifications. fischer Rugged Flash Drive. New. Rugged Solution for Safe Data Storage in Harsh Environment
fischer Rugged Flash Drive New Rugged Solution for Safe Data Storage in Harsh Environment Headquarters Fischer Connectors SA Ch. du Glapin 20 1162 Saint-Prex Switzerland Phone +41 21 800 95 95 [email protected]
Chlorinated polyethylene ELASLEN TM. Application for Wire and Cable
Chlorinated polyethylene ELASLEN TM Application for Wire and Cable 1 About the company Company Name : SHOWA DENKO K.K. Type of Industry : Diversified Chemical Company Formed : June 1, 1939 Employee : 10,577
Rapid Chloride Permeability Testing
Rapid Chloride Permeability Testing A test that can be used for a wide range of applications and quality control purposes if the inherent limitations are understood By Prakash Joshi and Cesar Chan C orrosion
to control the heat alongside the boiler to protect the more sensitive metal components against thermal, erosive and corrosive degradation
Testing procedures for refractory material in bottom grid of biomass/waste-fired CFBs 1 Karol Nicia, Edgardo Coda Zabetta 2 Mikko Hupa, Leena Hupa 1 Foster Wheeler Oy, Varkaus, Finland 2 Process Chemistry
Hydrophobe VII., Lisbon
Hydrophobe VII., Lisbon The water repellent treatment of building materials in thermal baths Debrecen, Hungary The geothermal potential in EU János Major University of Debrecen, Faculty of Thermal baths
PLEXIGLAS SUNACTIVE GS. For a Better Feeling
PLEXIGLAS SUNACTIVE GS For a Better Feeling PLEXIGLAS SUNACTIVE GS For a Better Feeling A perfect tan and a feeling of wellbeing are two important sales factors for tanning beds. To enable you to convincingly
B05: Cable protection and sheathing
SHEATHING MATERIALS MDPE, BLACK This is the standard sheathing material for cables for outdoor use. The material is UV stabilised with using 2.5 ± 0.5 % carbon black. It has excellent weathering resistance.
ENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics
ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany
Chemical-Resistant Epoxies for Secondary Containment by Christine Stanley Ameron Inc., Protective Coatings Group
Chemical-Resistant Epoxies for Secondary Containment by Christine Stanley Ameron Inc., Protective Coatings Group The coating of secondary containment areas is becoming more common as government regulation
INTAC PARTS & SERVICES (001308835-H)
DESCALING AND RUST REMOVAL SERVICES FOR TWIN SCREW EXTRUDER BARRELS Scale or lime-scale is a hard, rock-like deposit of calcium or magnesium salts that forms in heat exchangers, machinery cooling channels
Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008. Foundation Heave Protection
Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008 Foundation Heave Protection The safe, sure way to provide foundation protection Clayshield is the proven solution to protecting foundations against
PC-Concrete Injectable Concrete Anchoring and Repair System
PC-Concrete Injectable Concrete Anchoring and Repair System DESCRIPTION: PC-Concrete is a two component (1:1 ratio), 100% solids, high modulus, structural epoxy paste. PC-Concrete is a solvent free, no
4.461: Building Technology 1 CONSTRUCTION AND MATERIALS FALL TERM 2004 SCHOOL OF ARCHITECTURE AND PLANNING: MIT
4.461: Building Technology 1 CONSTRUCTION AND MATERIALS Professor John E. Fernandez FALL TERM 2004 SCHOOL OF ARCHITECTURE AND PLANNING: MIT Concrete and Composites Stadelhofen Station Zurich Santiago Calatrava
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS May 29, 2013 Revision B Structural Guideline for Design and Installation Holes in Composite Floor Slab Terminal 3, Departure Level
SOLVING SECONDARY CONTAINMENT PROBLEMS
SOLVING SECONDARY CONTAINMENT PROBLEMS CEILCOTE CORROSION CONTROL PRODUCTS Leadership in Corrosion Problem Solving CEILCOTE As the pioneer and technological leader in polymer linings, coatings and flooring
Inspired By Challenge. Technical information polymer characteristics
Inspired By Challenge Technical information polymer characteristics Technical Information Seat materials - overview Habonim s extensive field experience, which lets us design valves that meet the diverse
Part 13: Determination of secant modulus of elasticity in compression
ÖNORM EN 12390-13 Edition: 2013-12-15 Testing hardened concrete Part 13: Determination of secant modulus of elasticity in compression Prüfung von Festbeton Teil 13: Bestimmung des Elastizitätsmoduls unter
Technologies division. lead service pipe lining. Delivering what we promise
Technologies division lead service pipe lining 1 Keith Walker [email protected] Head of Morrison Utility Technologies 2 Contents Introduction to Morrison Utility Services Small diameter pipe
TECHNICAL REQUIREMENTS AND SPECIFICATIONS
TECHNICAL REQUIREMENTS AND SPECIFICATIONS REHABILITATION OF CONCRETE AND MASONRY MANHOLES OR UNDERGROUND VAULTS WITH A PROTECTIVE COATING (As Provided by Raven Lining Systems) FOREWORD This specification
North American Stainless
North American Stainless Long Products Stainless Steel Grade Sheet AISI 304 UNS S30400 EN 1.4301 AISI 304L UNS S30430 EN 1.4307 INTRODUCTION: Types 304 and 304L are the most versatile and widely used of
Accuracy counts! SENSORS WITH ANALOG OUTPUT
Accuracy counts! SENSORS WITH ANALOG OUTPUT OTHER APPLICATIONS: KEY ADVANTAGES: Distance measurement Positioning Profile detection Deformation monitoring Vibration monitoring Process monitoring Detection
R.J. O'Brien (UK) Limited BEST EXECUTION POLICY
Ground Floor - 25 Copthall Avenue - London - England - EC2R 7BP BEST EXECUTION POLICY Overview of Best Execution Requirement MiFID's best execution regime requires to take all reasonable steps to obtain
General Construction Foundations. Concrete Waterproofing by Crystallization
General Construction Foundations Concrete Waterproofing by Crystallization Meeting the Challenge Protecting Foundations The structural integrity of building foundations, whether deep or shallow, can be
Development of an innovative bio-based structural adhesive
Development of an innovative bio-based structural adhesive Blanca Palomo, R&D Engineer [email protected] RESCOLL Independent research company located in Pessac (33) specialized in technologic innovation
WATERPROOFING SikaProof -A TECHNOLOGY
SikaProof -A TECHNOLOGY content What is SikaProof -A? 6 How does it work? 8 Where can it be used? 0 What are the advantages of SikaProof -A? 2 How should it be installed? SikaProof -A system components
Concrete Repair and Protection
Concrete Repair and Protection with Remmers Systems Cleaning Equipment Cleaning Chemicals Corrosion Inhibitors Repair and Re-profiling Mortars Protective Impregnations and Coatings Repair and Protection
DENSO WATERPROOFING SYSTEMS
DENSO WATERPROOFING SYSTEMS Approved Quality Management System AS/NZS ISO 9001:2008 Lloyds Register Certificate N o Mel 0927759 Denso (Australia) Pty Ltd A MEMBER OF WINN & COALES INTERNATIONAL 411 413
PERSONAL PROTECTIVE EQUIPMENT POLICY & GUIDANCE
Health and Safety Policy PERSONAL PROTECTIVE EQUIPMENT POLICY & GUIDANCE ROYAL FREE HOSPITAL NHS TRUST & SCHOOL OF MEDICINE CONTENTS 1. SUMMARY OF THE REGULATIONS 2. INTRODUCTION 3. DEFINITION OF PERSONAL
Secure Data Drive Safe storage of sensitive data in harsh environments
Secure Data Drive Safe storage of sensitive data in harsh environments www.fischerconnectors.com FISCHER RUGGED FLASH DRIVE KEY FEATURES SAFE STORAGE IP68 sealed even unmated Extreme temperature resistant
External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902
External Wrapping of Steel Riser Pipe Case Study HJ3 CS200902 Introduction Refineries process a wide variety of petroleum products. As part of the process, they rely on cooling towers, which recycle water
Construction. Technology and Concepts for the Repair and Protection of Reinforced Concrete
Construction Technology and Concepts for the Repair and Protection of Reinforced Concrete Corrosion Management in Reinforced Concrete s The Key Stages in the Process 1Assessment Survey of the 2 Condition
Material and methods. Värmeforsk report 1212 2012 Niklas Hansson DIANAS utilization of waste inciniration bottom ash in bound construction materials
Värmeforsk report 1212 2012 Niklas Hansson DIANAS utilization of waste inciniration bottom ash in bound construction materials Executive Summary Introduction In an international perspective waste incineration
INTERIM ADVICE NOTE 96 /07 Revision 1 GUIDANCE ON IMPLEMENTING RESULTS OF RESEARCH ON BRIDGE DECK WATERPROOFING
Interim Advice Note 96/07 INTERIM ADVICE NOTE 96 /07 Revision 1 GUIDANCE ON IMPLEMENTING RESULTS OF RESEARCH ON BRIDGE DECK WATERPROOFING Summary This interim advice note provides guidance on improving
Dowel-Bar Retrofit Using Polyester Polymer Concrete
PPETG May 3-4, 2011, Oklahoma City Dowel-Bar Retrofit Using Polyester Polymer Concrete Shakir Shatnawi, Ph.D., P.E. President, SHATEC ENGINEERING CONSULTANTS, LLC [email protected] 916-990-6488 2
kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.
kalox-pool draft 231 KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete. repairing refurbishing and finishing 8-30 C Trowel / Spray 4 mm kalox-pool EN 1504-2 MAIN FEATURES
5big Backup Server. Quick Start Guide. Backup Appliance. Gigabit Ethernet DESIGN BY NEIL POULTON
5big Backup Server DESIGN BY NEIL POULTON Backup Appliance Gigabit Ethernet Quick Start Guide Box Content Your LaCie 5big Backup Server package contains the system tower and an accessories box that includes
Cold trichloroethylene degreasing Film Thickness 70± 10 µm 10 minutes at 170 C (PZ 770 alone) 5 minutes 30 sec. at 220 C (maximum curing conditions)
Product Datasheet Product Description Powder Properties Test Conditions BU Powder Coatings Interpon PZ 77 Interpon PZ 77 is a powder coating primer containing zinc which is designed to give enhanced corrosion
Out - Ecrano / 002010 White Charcoal
Out - Ecrano / 002010 White Charcoal front: back: Widths 270 cm TECHNICAL SPECIFICATION STANDARD RESULT composition Glassfibre 42% - PVC 58% openness factor NBN EN 410 2.00% weight NF EN 12127 650.00g/m²
1.5 Concrete (Part I)
1.5 Concrete (Part I) This section covers the following topics. Constituents of Concrete Properties of Hardened Concrete (Part I) 1.5.1 Constituents of Concrete Introduction Concrete is a composite material
The Real Service Life and Repair Costs for Bridge Edge Beams
The Real Service Life and Repair Costs for Bridge Edge Beams Hans-Åke MATTSSON*, Håkan SUNDQUIST ** *) MSc, PhD Student, Department of Civil and Architectural Engineering, Division of Structural Design
USB-2.0 Mobile Mini Hub USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.
USB-2.0 Mobile Mini Hub Making Your Mobile Life Easier. Visit our Web site at: www.targus.com Features and specifications are subject to change without notice. 2002 Targus Corp. 400-0093-001A USER S GUIDE
Viscosity - Flow Cups. elcometer.com
elcometer.com Viscosity - Flow Cups 1 Viscosity - Flow Cups Elcometer 2350 & 2354 Viscosity Flow Cups Viscosity Flow Cups are very easy to use instruments made of anodized aluminium with a stainless steel
IS THAT LINER THICK ENOUGH?
IS THAT LINER THICK ENOUGH? Philip McFarlane, Opus International Consultants Ltd ABSTRACT The amount of pipeline rehabilitation being undertaken in New Zealand is increasing each year. Larger diameter
SURFACE PREPARATION STANDARDS
SURFACE PREPARATION STANDARDS TE SWEDIS STANDARDS INSTITUTION: Surface Preparations Standards for Painting Steel Surface (SIS 055900-1967) has gained prominence and acceptance and has served as a model
Rely on Our Material Competence for Your Demanding Industrial Processes
Cast Materials Rely on Our Material Competence for Your Demanding Industrial Processes Our customer-focused R&D and continuous research on new material options enable us to develop equipment with a strong
ACOME. Complete systems for: radiant floor heating/cooling/plumbing.
ACOME Complete systems for: radiant floor heating/cooling/plumbing. Plumbing systems Hot and cold water distribution Principle: The appliances (plumbing, radiators, fan-coil units, etc.) are individually
Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.
Recommend Approval: Team Leader Date Division Chief Date Approved: Director Date Maryland Department of Transportation State Highway Administration Office of Materials Technology MARYLAND STANDARD METHOD
Final Report. Sacramento County Sanitation District No. 1. Engineering Sustainability of Piping Materials
Final Report Sacramento County Sanitation District No. 1 Engineering Sustainability of Piping Materials Vitrified Clay Pipe (VCP) and Polyvinyl Chloride (PVC) Pipe: A Comparison By: Kurt N. Ohlinger, Ph.D.,
Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IEC 17021:2011 to provide environmental management systems certification to Unit 6, Gordano Court Gordano Gate Business Park Serbert Close
OIL CONDITION MONITORING: AUTOMOTIVE ANALYSIS
OIL CONDITION MONITORING: AUTOMOTIVE ANALYSIS Why Analyse Lubricants? With increasing costs and tighter deadlines, the need for effective maintenance strategies is greater than ever before. So why not
Global Pricing Study 2011: "Weak pricing cuts profits by 25%" Short summary
Global Pricing Study 2011: "Weak pricing cuts profits by 25%" Short summary August 2011 Bonn Office Haydnstr. 36, 53115 Bonn, Germany Tel.: +49 228 9843-351, fax: +49 228 9843-380 e-mail: [email protected]
BUMAX. REYHER your partner for the BUMAX range
BUMAX high-tensile stainless steel fasteners REYHER your partner for the BUMAX range Strongest stainless steel fasteners in the world BUMAX 88 and BUMAX ready for delivery from stock Wide range of BUMAX
CEMENT CHEMISTRY & TYPES OF CEMENT
CEMENT CHEMISTRY & TYPES OF CEMENT Cement is a hydraulic binder, i.e., an inorganic, non-metallic, finely ground substance which, after mixing with water, sets and hardens independently as a result of
Heritage Stone Restorations. Tender Restoration Proposal. For. James Martin Statue. Gawler
Heritage Stone Restorations Tender Restoration Proposal For James Martin Statue Gawler 28 th November 2013 Town of Gawler, Att. Tony Haynes, 89 Murray Street, Gawler, SA 5118. Dear Tony, RE: James Martin