VBLOCK SOLUTION FOR GREENPLUM

Size: px
Start display at page:

Download "VBLOCK SOLUTION FOR GREENPLUM"

Transcription

1 VBLOCK SOLUTION FOR GREENPLUM August VCE Company, LLC. All rights reserved. 1

2 Table of Contents Introduction...4 Goal...4 Audience...4 Scope...4 Objectives...4 Greenplum Architecture Overview...5 Setup...6 Installation...6 Vblock Series 700 model MX Building Block Configuration Specifications for Greenplum...6 Greenplum Design and Configuration Details...7 Compute Unified Computing System (UCS) UCS Server Blade Provisioning Service Profile Template UCS Firmware UCS Network Configuration Greenplum Segment Server/ESX Server Provisioning Symmetrix VMAX Storage Array The Symmetrix VMAX Architecture Overview Hardware List Disk Layout Front-end Storage Port Layout RecoverPoint RecoverPoint VSAN Zoning RecoverPoint Consistency Groups TimeFinder/Snap Replication Manager VCE Company, LLC. All rights reserved. 2

3 Test Results Read and Load Performance Tests: Objectives and Results RecoverPoint Disaster Recovery Tests: Objectives and Results Conclusion References VCE Company, LLC. All rights reserved. 3

4 Introduction Goal The purpose of this document is to provide architecture for hosting the Greenplum application on Vblock Infrastructure Platforms. Specifically, the Greenplum application is hosted on the Vblock Series 700 model MX shared infrastructure and is part of a multi-applications environment. Vblock 700 delivers high-performance, largescale virtualization across data centers of large enterprise customers. It includes Cisco Unified Computing system, EMC Symmetrix VMAX, and VMware vsphere 4 and can include flash technology to meet the high-performance demands of mission-critical applications. The architecture provides a building block approach for hosting Greenplum applications. This approach is scalable and supports a dynamic workload in a cost effective model. The Vblock 700 enables enterprises to meet their mobility, disaster recovery, security, and optimized data life cycle management requirements for hosting Greenplum along with other applications. Audience The target audience for this document includes technical engineering staff, managers, IT planners, administrators, and others involved in evaluating, managing, operating, or designing Greenplum Vblock platform deployments. Scope The project demonstrates the ability to: Run the Greenplum application on the Vblock platform Prove that Greenplum Data Warehousing (DW) is a viable solution for use on a Vblock platform Objectives The business objectives of the new Vblock Solution for Greeplum include advantages in the following areas: Provide a proven performance platform for a Greenplum and Vblock 700 architecture Establish a building-block scalable model with predictable performance growth Provide a showcase environment for a Greenplum and Vblock 700 Greenplum Workload Tests using massively parallel processing (MPP) o MPP/Row and MPP/Columnar Load queries o MPP/Row Sequential Read and Random Read queries o MPP/Columnar Sequential Read and Random Read queries o Mixed Workloads Automated Virtualization Functionality o Scale out to a new ESX server infrastructure with six VMs per ESX host, for a total of forty-eight Greenplum Segment Server VMs o Monitor the I/O Workload of the VMs 2011 VCE Company, LLC. All rights reserved. 4

5 Greenplum Architecture Overview Greenplum Database is a massively parallel processing (MPP) database server based on PostgreSQL opensource technology. MPP (also known as a shared nothing architecture) refers to systems with two or more processors which cooperate to carry out an operation, each processor with its own memory, operating system, and disks. Greenplum leverages this high-performance system architecture to distribute the load of multi-terabyte data warehouses, and is able to use all of a system s resources in parallel to process a query. Greenplum Database is essentially several PostgreSQL database instances acting together as one cohesive database management system (DBMS). It is based on PostgreSQL 8.2.9, and in most cases is very similar to PostgreSQL with respect to SQL support, features, configuration options, and end-user functionality. Database users interact with Greenplum Database as they would a regular PostgreSQL DBMS. The internals of PostgreSQL have been modified or supplemented to support the parallel structure of Greenplum Database. For example, the system catalog, query planner, optimizer, query executor, and transaction manager components have been modified and enhanced to be able to execute queries in parallel across all of the PostgreSQL database instances at once. The Greenplum interconnect (the networking layer) enables communication between the distinct PostgreSQL instances and allows the system to behave as one logical database. Greenplum Database also includes features designed to optimize PostgreSQL for business intelligence (BI) workloads. For example, Greenplum has added parallel data loading (external tables), resource management, query optimizations, and storage enhancements which are not found in regular PostgreSQL. Many features and optimizations developed by Greenplum do make their way back into the PostgreSQL community, now in standard PostgreSQL. Figure 1. MPP Shared-nothing Architecture For further Greenplum information, see the following: VCE Company, LLC. All rights reserved. 5

6 Setup This section addresses the Greenplum setup. Installation The following link points to the Greenplum installation documentation. Vblock Series 700 model MX Building Block Configuration Specifications for Greenplum The 700MX building block configuration for Greenplum comprises forty-eight Greenplum Segment Server VMs running on eight Blades and two storage engines. It will support 4 GB/sec scan rate. More throughputs can be achieved by adding an additional pair of Vmax engines and disks, or by adding more building blocks. See below for additional details. Table 1 Building block configuration specifications for Greenplum 700MX Compute B200 M2 Blades 8 x B200 M2 Blades w/96gb memory per Blade (8 Blades for Greenplum Segment Servers) across two or more chassis 700MX Storage Symmetrix VMAX storage 2 Engines 16 x 8Gb/sec FC ports 192 x 300GB FC drives (excluding hot spares) 700MX Virtualization VMware vsphere ESX 4.0 U2 servers RAID5 (3+1) vcenter connects to another Windows 2008 R2 Enterprise Edition Server running SQLServer 2005 Enterprise Edition, setup per VMware s installation guide Greenplum application on Vblock platform VMware Distributed Virtual Switch Greenplum v4.006 software Greenplum Utilities GP PerfMon Psql GP-Load Greenplum Perl Greenplum Connectivity GP/port 5432 Scan Rate for the given building block GP PerfMon /port GB /sec This scan rate is achieved by using 2 x VMAX engines, 16 front-end processors and 192 x Fibre Channel (FC) 15K RPM disks). More throughputs can be achieved by adding additional pairs of VMAX engines and disks VCE Company, LLC. All rights reserved. 6

7 Greenplum Design and Configuration Details This section presents design and configuration details. Figures 2 and 3, below, illustrate the conceptual design through both the physical topology and the logical topology. The physical topology, figure 2, depicts the connectivity from the UCS to the SAN layer and LAN layer. In the SAN layer, a total of 16 x 8 Gb Fiber Channel (FC) connections were utilized from the USC Fabric Interconnects (A and B) to the MDS SAN directors. The SAN directors are fabric A and fabric B. VSANs 30, 130 are in director A, and VSANs 31 and 131 are in director B. VSANs 30 and 31 are backend VSANs consisting of the VMax storage ports and the RecoverPoint Appliance HBA ports. VSANs 130 and 131 are the corresponding front-end VSANs consisting of server HBA ports. In this case, the UCS blade servers are used as ESX servers. The front-end and backend VSANs are required by Cisco s SANTap to function as the write-splitter for RecoverPoint Appliances. In the LAN layer, a total of 16 x 10 Gb Ethernet port connections are used between the UCS Fabric Interconnects (A and B) and the Nexus 5020 access layer LAN switches, which in turn are connected to the Nexus 7000 switches as the aggregation layer. The logical topology is explained below, before figure VCE Company, LLC. All rights reserved. 7

8 Figure 2. Conceptual Design Physical Topology Diagram 2011 VCE Company, LLC. All rights reserved. 8

9 See Figure 3, below. The logical topology depicts the configuration of the backend disk, ESX host LUNs, VMs, and Greenplum components. A total of 26 x VMs were created on 10 x ESX servers (the UCS blade servers). 24 x VMs are used as the data segment servers, 2 x VMs are used as the master servers, one active and one standby node. The 24 VMs are evenly distributed across 8 x ESX servers, 3 x VMs per ESX server. The master servers (active and standby node) are on the ninth and tenth ESX blade servers. RecoverPoint was configured in local replication mode called Continuous Data Protection (CDP). Figure 3. Conceptual Design Logical Topology Diagram 2011 VCE Company, LLC. All rights reserved. 9

10 Compute Unified Computing System (UCS) UCS Server Blade Provisioning The Cisco Unified Computing System (UCS) allows provisioning of Physical Servers using a Template. In UCS terminology, a server is described as a Service Profile. The template allows users to deploy one or more service profiles as a Service Profile Template. In this Greenplum on Vblock 700 configuration, a total of eight Service Profiles were used. The following Service Profile Template details are used for deploying Greenplum on Vblock 700. Service Profile Template A Service Profile Template has the following components: 1. vnic Template: This template is used for vnic configuration for all Service Profiles deployed using a Service Profile Template. For Greenplum, disable the failover between vnics. 2. Each vnic has the following VLAN configuration: vnic 0 (vmnic0) vnic 1 (vmnic1) VLAN ID Service Console/Management vmotion Network Greenplum Segment VLan-1 * Public Network vlan** Service Console/Management vmotion Network Greenplum Segment VLAN 2 * Public Network vlan** Fabric ID A B *Greenplum segment VLANs are private VLANs and completely isolated from each other. If the UCS is equipped with Palo Cards, create one additional NIC in each fabric for the Greenplum segment network. **The Public Network VLAN accesses the Master Segment in the Greenplum setup VCE Company, LLC. All rights reserved. 10

11 3. vhba Template: This template is used for a vhba configuration for all service profiles deployed using a service profile template. For this setup, a total of eight fiber connections from each fabric Interconnect to the MDS Switches were used. Eight SAN Pin Groups also were created. This way, each Service Profile has a dedicated SAN Connection. The FC Adapter policy for VMware was used for all the vhbas. vhba-1 vhba-2 VSAN ID Fabric ID A B 4. Boot Policy: Four Boot policies were created, which were named Boot from SAN (BFS). Each Boot policy points to front-end directors of the EMC Symmetrix VMAX storage array. Boot From SAN Policies (BFS) Policy 1: Policy 2: Policy 3: 2011 VCE Company, LLC. All rights reserved. 11

12 Policy 4: 5. MAC pools for each fabric: In this setup, we have two MAC Pools, one for each fabric. The UCS blade allows users to modify the last three octets of the MAC Address pools VCE Company, LLC. All rights reserved. 12

13 6. World Wide Node and Port Name Pool: In this setup, two WWPN Pools were used, one for each fabric. The UCS blade allows users to modify the last three octets of the worldwide port and node names. The Universal Unique Identifier (UUID) pool for each Service Profile: 7. Service Profile Template and Service Profiles: The results achieved at the end of the whole process are shown in the following figure. Service Profiles gpesx , and gpesx , were used to host the Greenplum (segment server) virtual machines. Service profiles gpesx107 and gpesx207 formed the management cluster for the Greenplum environment VCE Company, LLC. All rights reserved. 13

14 UCS Firmware The latest firmware available at the time, 1.3 (1c), was used for this deployment. Additionally, to enable the Palo interface cards, it is necessary to attach the firmware package with each service profile. This can be done in the service profile template, which then propagates the firmware to each service profile bound to this template. It is also necessary to update the BIOS to the latest version using a firmware package. The following shows a firmware package, which has Palo card (M81KR) firmware, and BIOS updates. To apply the update to all service profiles: 1. In the Service Profile template, go to Policies. 2. Select the firmware package as shown below: UCS Network Configuration 1. Create uplink ports for etherenet traffic. 2. Under networking, configure the LAN and SAN. LAN Configuration Ports 1/37-40 were selected as uplink ports for 10GB ethernet traffic. The following screen captures show the port channel (LAN) configurations on the fabric interconnect. Port-Channels used on the UCS 2011 VCE Company, LLC. All rights reserved. 14

15 Port-channel Configuration details for fabric Interconnect A Port-channel Configuration details for fabric Interconnect B SAN Configuration on Fabric Interconnects There are a total of eight fiber channel ports in use on the fabric interconnect. SAN Pin groups are created to isolate SAN traffic. The following screen capture shows the SAN Pin Group configurations on the fabric interconnect VCE Company, LLC. All rights reserved. 15

16 Greenplum Segment Server/ESX Server Provisioning VM servers are provisioned as follows: 3 x VMs are created per ESX server on a total of 8 x ESX servers. These are used as Greenplum segment servers. 1 x VM is created on a 9th ESX server. It is used as the Greenplum Master/metadata Server. This server also handles client requests. 1 x VM is created on a 10th ESX server. It is used as the Greenplum Standby Server. Note: XFS-formatted devices on VMware ESX Guest RDMs are recommended for GP data segments for the highest performance. The table below provides the VM/ESX storage configuration details. Table 2 VM/ESX storage configuration details 2011 VCE Company, LLC. All rights reserved. 16

17 The following diagram depicts the graphical layout of a single blade, with an ESX instance and a VM (Greenplum Data Segment server) with two LUNs (FC) per VM. The ESX environment is located on the 500GB LUN, which holds the three VM instances. Figure 4. VM/ESX/LUN Layout The following setup shows the ESX Servers in the vcenter server. In this setup, there are six (only three VMs are used) Greenplum Segment servers (gpssx) on a single ESX server VCE Company, LLC. All rights reserved. 17

18 The following shows the Greenplum Segment Servers (gpssx) Virtual Machines distribution on single ESX servers. The VM distribution on the remaining seven ESX servers is identical to gpesx101.gp.vce Other Management Virtual Machines are hosted on the following ESX server. These include the vcenter server, SQL Server Database and EMC Control Center VCE Company, LLC. All rights reserved. 18

19 Symmetrix VMAX Storage Array The Symmetrix VMAX Architecture Overview At the heart of the Symmetrix VMAX series storage array architecture is the scalable Virtual Matrix interconnect design. The Virtual Matrix is redundant and dual active, and supports all Global Memory references, messaging, and management operations including internal discovery and initialization, path management, load balancing, failover, and fault isolation within the array. The Symmetrix VMAX array comprises from one to eight VMAX Engines. Each VMAX Engine contains two integrated directors. Each director has two connections to the VMAX Matrix Interface Board Enclosure (MIBE) via the System Interface Board (SIB) ports. Since every director has two separate physical paths to every other director via the Virtual Matrix, this is a highly available interconnect with no single point of failure. This design eliminates the need for separate interconnects for data, control, messaging, environmental, and system test. A single highly-available interconnect suffices for all communications between the directors, which reduces complexity. Figure 5. Symmetrix VMAX Virtual Matrix Interconnect The Symmetrix VMAX design is based on an individual Symmetrix VMAX engine with redundant CPU, memory, and connectivity on two directors for fault tolerance. Symmetrix VMAX engines connect to and scale-out linearly through the Virtual Matrix Architecture, which allows resources to be shared within and across VMAX Engines. To meet growth requirements, additional VMAX Engines can be added non-disruptively for efficient and dynamic scaling of capacity and performance, while dramatically simplifying and automating operational tasks are critical to addressing the infrastructure requirements and driving down cost in both virtual and physical deployments. The following figure illustrates the building block approach VCE Company, LLC. All rights reserved. 19

20 Symmetrix VMAX Engine Building Block Easily Add More Symmetrix VMAX Engines Virtual Servers Front End Back End Front End Back End Host & Disk Ports Host & Disk Ports Symmetrix VMAX Engine Core Core Core Core Global Memory Core Core Core Core CPU Complex Virtual Matrix Interface A B Core Core Core Core CPU Complex Core Core Core Core Global Memory Virtual Matrix Interface A B VMAX Engine VMAX Engine VMAX Engine VMAX Engine VMAX Engine VMAX Engine VMAX Engine VMAX Engine Figure 6. Symmetrix VMAX Engine Building Blocks Hardware List Number of VMAX Engines: 2 Global Memory (GB): 256 Number of Front End (8 Gbps Ports): 32 ports Number of 300G (15K RPM) FC disks (excluding hot spares): 192 Disk Layout 48 x RAID5(3+1) RAID groups are created out of the total 192 x Fibre Channel (FC) disks o 24 x RAID groups are used as RecoverPoint CDP source o 24 x RAID groups are used as RecoverPoint CDP target Two 190 GB hyper volumes are created from each RAID group One concatenated metavolume is created from the above hyper-volumes from each RAID group. This is to achieve IO isolation on disk level. Each metavolume is allocated to each of the total 24 Greenplum segment VMs as an RDM disk 2011 VCE Company, LLC. All rights reserved. 20

21 Processor # Figure 7. Greenplum Backend Disk Layout on VMAX Front-end Storage Port Layout 2 x Engines 4 x Directors 16 x front-end processors, 2 x FC ports on each 2 x FC ports on each processor with total 32 x 8 Gbs FC ports. 16 FC ports (from each processor) are utilized In this configuration, only 16 x FC ports are used. Port 0 is taken from each processor. See figure below. Engine 4-128G Engine 5-128G Dir 7 Port Port Dir 8 Port Port Dir 9 Port Port Dir 10 Port Port H FA 0 1 FA 0 1 FA 0 1 FA 0 1 G FA 0 1 FA 0 1 FA 0 1 FA 0 1 F FA 0 1 FA 0 1 FA 0 1 FA 0 1 E FA 0 1 FA 0 1 FA 0 1 FA 0 1 Figure 8. Greenplum Front-end Storage Port layout VMax Mask View (LUN masking): A total of 10 x Mask Views are configured, 8 x for the ESX hosts running Greenplum segment VMs, 1 x for the ESX host running Greenplum master VM server, 1 x for the ESX host running standby VM server. Each ESX server HBA initiator accesses storage via 2 x Vmax storage ports, or total of 4 x Vmax storage ports per ESX server (with dual HBAs). For more information about Symmetrix VMAX, see the product documentation: pdf?mtcs=ZXZlbnRUeXBlPUttQ2xpY2tDb250ZW50RXZlbnQsZG9jdW1lbnRJZD0wOTAxNDA2NjgwNTIyMz FkLG5hdmVOb2RlPVNvZndhcmVEb3dubG9hZHMtMg 2011 VCE Company, LLC. All rights reserved. 21

22 RecoverPoint RecoverPoint is EMC s leading out-of-band, block-level replication product for a heterogeneous server and storage environment. RecoverPoint continuous data protection (CDP) provides local synchronous replication between LUNs that reside in one or more arrays at the same site. RecoverPoint continuous remote replication (CRR) provides remote asynchronous replication between two sites for LUNs that reside in one or more arrays. Both RecoverPoint CDP and RecoverPoint CRR feature bi-directional replication and an any-point-in-time recovery capability, which allows the target LUNs to be rolled back to a previous point in time and used for read/write operations without affecting the ongoing replication or data protection. The bi-directional replication and any-point-in-time recovery capability can be enabled simultaneously with RecoverPoint concurrent local and remote (CLR) data protection. RecoverPoint supports three types of write-splitting technologies for maximal flexibility. Table 3 Splitter details Splitter Type How Deployed Overhead Host-based In I/O stack just above the multi-path software Adds write traffic at the HBA; no other impact Fabric-based In intelligent storage services hardware on a Brocade- or Cisco-based switch Operates at wire speeds; no impact CLARiiON-based In FLARE operating system; active in both storage processors No impact In the Greenplum configuration, the Cisco SANTap service is used in a RecoverPoint CDP deployment. Cisco 18/5 MSMs (Multi Service Modules) are installed in MDS Both the GP segment server data and the GP master metadata replicate locally on the VMAX for continuous data protection. See figure 9, below VCE Company, LLC. All rights reserved. 22

23 Intelligentfabric splitter 1. Data is split and sent to the RecoverPoint appliance in one of three ways 3. Writes are acknowledged back from the RecoverPoint appliance / A / B / C r A r B r C Production volumes Replica volumes Journal volume 4. The appliance writes data to the journal volume, along with time stamp and application-specific bookmarks Figure Write-order-consistent data is distributed to the replica volumes RecoverPoint Sequence RecoverPoint VSAN Zoning RecoverPoint with Cisco SANTap deployment requires placing different components into two VSANs: Front-end VSAN Backend VSAN All I/O activity between the host and the storage is relayed by SANTap from the actual host port via the DVT (Data Virtual Target) in the front-end VSAN to the VI (Virtual Initiator) in the backend VSAN, and then to the actual storage port. This relay mechanism is completely transparent to the hosts. The following types of zones are required for each VSAN. Zones in the backend VSAN The backend VSAN contains the physical storage ports, the RecoverPoint Appliance HBA ports, the CVTs (control virtual targets created by SANTap service), and AVTs (Appliance Virtual Targets, created by the RecoverPoint Appliance): Zone Type 1 - a zone that contains a member of the ESX server HBA virtual initiators and the corresponding physical storage ports. These zones were almost identical to the zones in the front-end VSAN that contain the host HBA port and DVTs. See explanation below. Zone Type 2 - a zone that contains a member of the RPA HBA port and the physical storage ports. This allows the RPAs to access the storage on the Vmax. Zone Type 3 - a zone that contains RPA HBA ports and CVTs. This allows the RPA to request the CVT to open a splitting session. The I/O is then copied to the RPA, allowing the RPA to replicate data to the target. Zone Type 4 - a zone that contains RPA HBA ports and the AVTs VCE Company, LLC. All rights reserved. 23

24 AVT are used to mask the identity of the appliance (RPA), allowing it to appear as the host. This masking is necessary to allow the RPA to overcome SCSI reservation of storage ports by the hosts and to get the same view of the SAN that the hosts have. Zones in the front-end VSAN A zone that is between the host HBA ports, in this case the UCS blade server HBA ports, and the SANTap Data Virtual Targets (the DVTs). Note: DVTs are created as the virtual storage port entity during SANTap configuration. Each physical storage port used in the backend VSAN would need a corresponding DVT created. For more information, see the following zoning tables. Table 4 RecoverPoint VSAN zoning table: Fabric A Fabric A, VSAN 30 (BE VSAN) Zone Member Member Member gpesx101_hba1_vmax gpesx101_hba1 Vmax_8eA Vmax_10eA gpesx102_hba1_vmax gpesx102_hba1 Vmax_8fA Vmax_10fA gpesx103_hba1_vmax gpesx103_hba1 Vmax_8gA Vmax_10gA gpesx104_hba1_vmax gpesx104_hba1 Vmax_8hA Vmax_10hA gpesx107_hba1_vmax gpesx107_hba1 Vmax_8gA Vmax_10gA gpesx201_hba1_vmax gpesx201_hba1 Vmax_8eA Vmax_10eA gpesx202_hba1_vmax gpesx202_hba1 Vmax_8fA Vmax_10fA gpesx203_hba1_vmax gpesx203_hba1 Vmax_8gA Vmax_10gA gpesx204_hba1_vmax gpesx204_hba1 Vmax_8hA Vmax_10hA gpesx207_hba1_vmax gpesx207_hba1 Vmax_8gA Vmax_10gA RPA1_HBA1_2_Vmax RPA1_HBA1 Vmax_8eA Vmax_10eA RPA1_HBA2 Vmax_8fA Vmax_10fA Vmax_8gA Vmax_10gA Vmax_8hA Vmax_10hA Vmax_8gA Vmax_10gA RPA8_HBA1_2_Vmax RPA8_HBA1 Vmax_8eA Vmax_10eA RPA8_HBA2 Vmax_8fA Vmax_10fA Vmax_8gA Vmax_10gA Vmax_8hA Vmax_10hA Vmax_8gA Vmax_10gA RPA_CVT_A All above RPA HBA ports All SANTap CVTs in Fabric A RPA_AVT_A All above RPA HBA ports All RPA AVTs 2011 VCE Company, LLC. All rights reserved. 24

25 Table 5 RecoverPoint VSAN zoning table: Fabric B Fabric B, VSAN 31 (BE VSAN) Zone Member Member Member gpesx101_hba2_vmax gpesx101_hba2 Vmax_9eA Vmax_7eA gpesx102_hba2_vmax gpesx102_hba2 Vmax_9fA Vmax_7fA gpesx103_hba2_vmax gpesx103_hba2 Vmax_9gA Vmax_7gA gpesx104_hba2_vmax gpesx104_hba2 Vmax_9hA Vmax_7hA gpesx107_hba2_vmax gpesx107_hba2 Vmax_9gA Vmax_7gA gpesx201_hba2_vmax gpesx201_hba2 Vmax_9eA Vmax_7eA gpesx202_hba2_vmax gpesx202_hba2 Vmax_9fA Vmax_7fA gpesx203_hba2_vmax gpesx203_hba2 Vmax_9gA Vmax_7gA gpesx204_hba2_vmax gpesx204_hba2 Vmax_9hA Vmax_7hA gpesx207_hba2_vmax gpesx207_hba2 Vmax_9gA Vmax_7gA RPA1_HBA3_4_Vmax RPA1_HBA3 Vmax_9eA Vmax_7eA RPA1_HBA4 Vmax_9fA Vmax_7fA Vmax_9gA Vmax_7gA Vmax_9hA Vmax_7hA Vmax_9gA Vmax_7gA RPA8_HBA3_4_Vmax RPA8_HBA3 Vmax_9eA Vmax_7eA RPA8_HBA4 Vmax_9fA Vmax_7fA Vmax_9gA Vmax_7gA Vmax_9hA Vmax_7hA Vmax_9gA Vmax_7gA RPA_CVT_B All above RPA HBA ports All SANTap CVTs in Fabric B RPA_AVT_B All above RPA HBA ports All RPA AVTs Table 6 RecoverPoint VSAN zoning table: Fabric A Fabric A', VSAN 130 (FE VSAN) Zone Member Member (DVT) Member (DVT) gpesx101_hba1_vmax gpesx101_hba1 Vmax_8eA Vmax_10eA gpesx102_hba1_vmax gpesx102_hba1 Vmax_8fA Vmax_10fA gpesx103_hba1_vmax gpesx103_hba1 Vmax_8gA Vmax_10gA gpesx104_hba1_vmax gpesx104_hba1 Vmax_8hA Vmax_10hA gpesx107_hba1_vmax gpesx107_hba1 Vmax_8gA Vmax_10gA gpesx201_hba1_vmax gpesx201_hba1 Vmax_8eA Vmax_10eA gpesx202_hba1_vmax gpesx202_hba1 Vmax_8fA Vmax_10fA gpesx203_hba1_vmax gpesx203_hba1 Vmax_8gA Vmax_10gA gpesx204_hba1_vmax gpesx204_hba1 Vmax_8hA Vmax_10hA gpesx207_hba1_vmax gpesx207_hba1 Vmax_8gA Vmax_10gA 2011 VCE Company, LLC. All rights reserved. 25

26 Table 7 RecoverPoint VSAN zoning table: Fabric B Fabric B', VSAN 131 (FE VSAN) Zone Member Member (DVT) Member (DVT) gpesx101_hba2_vmax gpesx101_hba2 Vmax_9eA Vmax_7eA gpesx102_hba2_vmax gpesx102_hba2 Vmax_9fA Vmax_7fA gpesx103_hba2_vmax gpesx103_hba2 Vmax_9gA Vmax_7gA gpesx104_hba2_vmax gpesx104_hba2 Vmax_9hA Vmax_7hA gpesx107_hba2_vmax gpesx107_hba2 Vmax_9gA Vmax_7gA gpesx201_hba2_vmax gpesx201_hba2 Vmax_9eA Vmax_7eA gpesx202_hba2_vmax gpesx202_hba2 Vmax_9fA Vmax_7fA gpesx203_hba2_vmax gpesx203_hba2 Vmax_9gA Vmax_7gA gpesx204_hba2_vmax gpesx204_hba2 Vmax_9hA Vmax_7hA gpesx207_hba2_vmax gpesx207_hba2 Vmax_9gA Vmax_7gA RecoverPoint Consistency Groups RecoverPoint replicates data by using logical groups called Consistency Groups (CGs). Each Consistency Group contains one or many replication sets. Each replication set is a paring between the replication source LUN and target LUN. Since each Consistency Group can be active on a particular RPA, in order to utilize all 8 x RPAs for optimal performance, a total of 8 x CGs were created with each CG containing 3 x replication sets. A Group Set was created to contain all 8 x CGs to provide replication consistency for the entire Greenplum environment. Data consistency is maintained at the Group Set level. This allows rapid, point-in-time recovery of the Greenplum environment. Below is the Consistency Group configuration table VCE Company, LLC. All rights reserved. 26

27 Table 8 RecoverPoint consistency group configuration table For more information about RecoverPoint, see the RecoverPoint documentation set located at: =0b f517e&_irrt=true&rnavid=PT-2%3A0b fed VCE Company, LLC. All rights reserved. 27

28 TimeFinder/Snap TimeFinder provides local storage replication for increased application availability and faster data recovery. Leveraging the industry leading high-end EMC Symmetrix system, TimeFinder offers unmatched deployment flexibility and massive scalability to meet any service level requirement. TimeFinder helps companies perform backups, load data warehouses, and easily provide data for application test and development without downtime. TimeFinder/Snap provides the following: Storage-based information replication; no-host cycles Snapshots create logical point-in-time images of a source volume Requires only a fraction of the source volume s capacity (~20 30%) Multiple snapshots can be created from a source volume and are available immediately Snapshots support both read and write processing In the Greenplum Vblock platform, SATA disks are configured into a Snap pool for the snaps. Production volume Production view Figure 10. TimeFinder/Snap Save area Snapshot view Cache-based pointer map Replication Manager Replication Manager (RM) is EMC s software that improves access to information by automating and managing disk-based replicas. Replication Manager is used to manage the TimeFinder Snap operations. Key benefits are that it: Automates the creation, management, and use of EMC disk-based, point-in-time replicas Auto-discovers the environment Has intelligence to orchestrate replicas with deep application awareness Is easy to use with point-and-click controls, wizards, and user access Supports VMware ESX Server Windows and Linux guest operating system environments and Virtual Machine File System (VMFS) containing virtual machines, and: o Reduces backup windows o Minimizes/eliminates impact on the application o Improves Recovery Point Objectives (RPO) and Recovery Time Objectives(RTO) 2011 VCE Company, LLC. All rights reserved. 28

29 o Enhances productivity o Offers data-warehouse refreshes o Provides decision support o Provides database-recovery checkpoints o Enables application development and testing o Enables fast restore o Enables application restart and business resumption 2011 VCE Company, LLC. All rights reserved. 29

30 Test Results This section presents the objectives and results for two different, complementary test sets: Tests of the read and load performance with Greenplum database on the Vblock 700 Tests of disaster recovery success with the RecoverPoint appliance Read and Load Performance Tests: Objectives and Results The following tests were performed with the Greenplum DB on a Vblock 700. Table 9 Read and load performance test objectives Test Objective 1. Test Greenplum read performance on a Vblock 700 with the specified building block. 2. Test Greenplum load performance on a Vblock 700. Description Test read scan rate and query response time on a Vblock 700 with a specific building block as previously described. Database size: eight TB Test data load rate on Vblock 700 with a specific building block as previously described. Database size: eight TB Table 10 Test Scenario Test 1: Read test summary and results Description Run a stored procedure with two variations: 1. One sequential run with no other workload on the system. 2. One sequential run while additional workload is being run on the system. Test Result 1. One sequential run with no other workload on the system. 2. One sequential run while additional workload was being run on the system. Read scan query and response times. Description Run #1 result: 9.6 minutes for 15 million records Run #2 result: 11.1 minutes for 15 million records Online = 1100 queries completed Production = 50 jobs completed Ad hoc = 15 jobs completed 2011 VCE Company, LLC. All rights reserved. 30

31 Table 11 Test Scenario Test 2: Load test summary and results Description 1. Load an empty monthly partition with one day of data. 2. Load a half full monthly partition with one day of data. 3. Load a full monthly partition with one day of data. Test Result 1. Empty Partition Load = minutes 2. Half Full Partition Load = minutes 3. Full Partition Load = minutes One day of data equated to roughly 15 million records. Description Met performance metrics. RecoverPoint Disaster Recovery Tests: Objectives and Results The RecoverPoint (RP) appliance replication capability is leveraged to perform site Disaster Recovery (DR) testing. The following test scenarios to validate the DR testing solutions are within the BI/DW solution stack proposed by EMC. The objectives and results for four tests are summarized in the following tables. Table 12 Test Objective Objectives for DR Site recovery tests using RecoverPoint replication Description 1. Verify the Point in Time (PIT) bookmark for entire dataset. 2. Verify that the Point in Time (PIT) image was the correct image. 3. Verify that Snapshot consolidation works correctly. 4. Switch over the production DB to the secondary side. Perform a local bookmark function test to verify that users have access to the database. Perform a PIT copy on production. Enable Snapshot consolidation. Switch over to target side VCE Company, LLC. All rights reserved. 31

32 Table 13 Test 1: Bookmark test summary and results Test Scenario Follow a sequence of steps to place the database in and out of suspend mode, while enabling the image on secondary hosts. Test Result 1. Place database in gp suspend mode. 2. Create RP BM. 3. Take the database out of gp suspend mode. 4. Enable the image on secondary hosts. 5. Mount BM image. 6. Start database. 7. Verify PIT. Description Verify that the database is open and accessible. Description Database was open and DBA s were able to access the database. Table 14 Test 2: PIT image test summary and results Test Scenario Copy a PIT image before inserting records to production. Test Result 1. DBAs insert 35 million records on production 2. A PIT image is copied. 3. DBAs are able to get correct image before the insert. Description Verify that the correct PIT image is copied before inserting 35 million records into production. Description DBAs successfully copied correct image on production. Table 15 Test 3: Snapshot consolidation summary and results Test Scenario Bookmark an image during Snapshot consolidation. Test Result 1. DBA restores the Snapshot consolidation bookmark. Description DBA must verify the image on Snapshot consolidation. Description DBA successfully completed Snapshot-consolidated image VCE Company, LLC. All rights reserved. 32

33 Table 16 Test 4: Switch production DB summary and results Test Scenario Determine the latest point in time image and switch over from the production database to the target DB. Test Result 1. Enable the latest point in time image and switch over the production DB to the target DB. Description Target DB has to be primary. Description Successfully completed VCE Company, LLC. All rights reserved. 33

34 Conclusion Our testing supports the benefits of the building block system approach used for hosting Greenplum applications. Key results from the read and load performance tests illustrate the scalability of Greenplum on a Vblock 700 solution: The Read Test results show that the scan rate and query response time on Vblock 700 have a similar read performance time whether a stored procedure was run alone where results showed 9.6 minutes to read 15 million records, or run with additional workload on the system where the results achieved were 11.1 minutes to read 15 million records. The Load Test results showed a similar load performance time whether the load was an empty partition load with results at minutes, a half full partition load with results at minutes, or a full partition load with results at minutes. The key results from the RecoverPoint tests show the successful recovery and restoration of the database image and validate the disaster recovery solution included in the system VCE Company, LLC. All rights reserved. 34

35 References For further Greenplum information, see the following: Greenplum installation DOC link Introduction to EMC RecoverPoint 3.3 New Features and Functions Applied Technology white paper RecoverPoint Guides full set =0b f517e&_irrt=true&rnavid=PT-2%3A0b fed7 Symmetrix VMAX product guide pdf?mtcs=ZXZlbnRUeXBlPUttQ2xpY2tDb250ZW50RXZlbnQsZG9jdW1lbnRJZD0wOTAxNDA2NjgwNTIyMz FkLG5hdmVOb2RlPVNvZndhcmVEb3dubG9hZHMtMg ABOUT VCE VCE, the Virtual Computing Environment Company formed by Cisco and EMC with investments from VMware and Intel, accelerates the adoption of converged infrastructure and cloud-based computing models that dramatically reduce the cost of IT while improving time to market for our customers. VCE, through the Vblock platform, delivers the industry's first completely integrated IT offering with end-to-end vendor accountability. VCE prepackaged solutions are available through an extensive partner network, and cover horizontal applications, vertical industry offerings, and application development environments, allowing customers to focus on business innovation instead of integrating, validating and managing IT infrastructure. For more information, go to THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." VCE MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OR MECHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Copyright 2011 VCE Company, LLC. All rights reserved. Vblock and the VCE logo are registered trademarks or trademarks of VCE Company, LLC. and/or its affiliates in the United States or other countries. All other trademarks used herein are the property of their respective owners VCE Company, LLC. All rights reserved. 35

IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology

IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology White Paper IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology Abstract EMC RecoverPoint provides full support for data replication and disaster recovery for VMware ESX Server

More information

SAN Conceptual and Design Basics

SAN Conceptual and Design Basics TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer

More information

VBLOCK SOLUTION FOR SAP APPLICATION HIGH AVAILABILITY

VBLOCK SOLUTION FOR SAP APPLICATION HIGH AVAILABILITY Vblock Solution for SAP Application High Availability Table of Contents www.vce.com VBLOCK SOLUTION FOR SAP APPLICATION HIGH AVAILABILITY Version 2.0 February 2013 1 Copyright 2013 VCE Company, LLC. All

More information

EMC PERFORMANCE OPTIMIZATION FOR MICROSOFT FAST SEARCH SERVER 2010 FOR SHAREPOINT

EMC PERFORMANCE OPTIMIZATION FOR MICROSOFT FAST SEARCH SERVER 2010 FOR SHAREPOINT Reference Architecture EMC PERFORMANCE OPTIMIZATION FOR MICROSOFT FAST SEARCH SERVER 2010 FOR SHAREPOINT Optimize scalability and performance of FAST Search Server 2010 for SharePoint Validate virtualization

More information

VBLOCK SOLUTION FOR SAP: SIMPLIFIED PROVISIONING FOR OPERATIONAL EFFICIENCY

VBLOCK SOLUTION FOR SAP: SIMPLIFIED PROVISIONING FOR OPERATIONAL EFFICIENCY VBLOCK SOLUTION FOR SAP: SIMPLIFIED PROVISIONING FOR OPERATIONAL EFFICIENCY August 2011 2011 VCE Company, LLC. All rights reserved. 1 Table of Contents Introduction... 3 Purpose... 3 Audience... 3 Scope...

More information

LEVERAGE VBLOCK SYSTEMS FOR Esri s ArcGIS SYSTEM

LEVERAGE VBLOCK SYSTEMS FOR Esri s ArcGIS SYSTEM Leverage Vblock Systems for Esri's ArcGIS System Table of Contents www.vce.com LEVERAGE VBLOCK SYSTEMS FOR Esri s ArcGIS SYSTEM August 2012 1 Contents Executive summary...3 The challenge...3 The solution...3

More information

Building the Virtual Information Infrastructure

Building the Virtual Information Infrastructure Technology Concepts and Business Considerations Abstract A virtual information infrastructure allows organizations to make the most of their data center environment by sharing computing, network, and storage

More information

EMC Business Continuity for Microsoft SQL Server 2008

EMC Business Continuity for Microsoft SQL Server 2008 EMC Business Continuity for Microsoft SQL Server 2008 Enabled by EMC Celerra Fibre Channel, EMC MirrorView, VMware Site Recovery Manager, and VMware vsphere 4 Reference Architecture Copyright 2009, 2010

More information

Network-based Intelligent Data Protection Yossi Mossel, Product Manager

Network-based Intelligent Data Protection Yossi Mossel, Product Manager 1 EMC RecoverPoint Network-based Intelligent Data Protection Yossi Mossel, Product Manager The CIO s Information-Storage and -Management Requirements Lower TCO Utilization, consolidation, automated management

More information

VBLOCK SOLUTION FOR SAP: SAP APPLICATION AND DATABASE PERFORMANCE IN PHYSICAL AND VIRTUAL ENVIRONMENTS

VBLOCK SOLUTION FOR SAP: SAP APPLICATION AND DATABASE PERFORMANCE IN PHYSICAL AND VIRTUAL ENVIRONMENTS Vblock Solution for SAP: SAP Application and Database Performance in Physical and Virtual Environments Table of Contents www.vce.com V VBLOCK SOLUTION FOR SAP: SAP APPLICATION AND DATABASE PERFORMANCE

More information

EMC Solutions for Disaster Recovery

EMC Solutions for Disaster Recovery EMC Solutions for Disaster Recovery EMC RecoverPoint Daniel Golic, Technology Consultant Banja Luka, May 27 th 2008 1 RecoverPoint 3.0 Overview 2 The CIO s Information Storage and Management Requirements

More information

EMC Business Continuity for VMware View Enabled by EMC SRDF/S and VMware vcenter Site Recovery Manager

EMC Business Continuity for VMware View Enabled by EMC SRDF/S and VMware vcenter Site Recovery Manager EMC Business Continuity for VMware View Enabled by EMC SRDF/S and VMware vcenter Site Recovery Manager A Detailed Review Abstract This white paper demonstrates that business continuity can be enhanced

More information

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution EMC Virtual Infrastructure for Microsoft Applications Data Center Solution Enabled by EMC Symmetrix V-Max and Reference Architecture EMC Global Solutions Copyright and Trademark Information Copyright 2009

More information

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer The Future of Computing Cisco Unified Computing System Markus Kunstmann Channels Systems Engineer 2009 Cisco Systems, Inc. All rights reserved. Data Centers Are under Increasing Pressure Collaboration

More information

MICROSOFT HYPER-V SCALABILITY WITH EMC SYMMETRIX VMAX

MICROSOFT HYPER-V SCALABILITY WITH EMC SYMMETRIX VMAX White Paper MICROSOFT HYPER-V SCALABILITY WITH EMC SYMMETRIX VMAX Abstract This white paper highlights EMC s Hyper-V scalability test in which one of the largest Hyper-V environments in the world was created.

More information

Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems

Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems Applied Technology Abstract This white paper investigates configuration and replication choices for Oracle Database deployment with EMC

More information

VBLOCK SOLUTION FOR SAP: HIGH AVAILABILITY FOR THE PRIVATE CLOUD

VBLOCK SOLUTION FOR SAP: HIGH AVAILABILITY FOR THE PRIVATE CLOUD Vblock Solution for SAP: High Availability for the Private Cloud Table of Contents www.vce.com VBLOCK SOLUTION FOR SAP: HIGH AVAILABILITY FOR THE PRIVATE CLOUD Version 2.0 February 2013 1 Copyright 2013

More information

EMC RecoverPoint Continuous Data Protection and Replication Solution

EMC RecoverPoint Continuous Data Protection and Replication Solution EMC RecoverPoint Continuous Data Protection and Replication Solution Simple. Efficient. Consistent Dejan Živanović EMC Technology Solutions Group SEE Presales Manager Dejan.Zivanovic@emc.com 1 Real Time

More information

EMC Symmetrix V-Max and Microsoft SQL Server

EMC Symmetrix V-Max and Microsoft SQL Server EMC Symmetrix V-Max and Microsoft SQL Server Applied Technology Abstract This white paper examines deployment and integration of Microsoft SQL Server solutions on the EMC Symmetrix V-Max Series with Enginuity.

More information

EMC RECOVERPOINT FAMILY

EMC RECOVERPOINT FAMILY EMC RECOVERPOINT FAMILY Cost-effective local and remote data protection and disaster recovery solution ESSENTIALS Maximize application data protection and disaster recovery Protect business applications

More information

EMC: The Virtual Data Center

EMC: The Virtual Data Center EMC: The Virtual Data Center Dejan Živanovi EMC Technology Solution Group Sr. Technology Consultant High-End platforms & Business Continuity 1 Business Challenges Data growing at 70% annually 80% are files

More information

Virtual SAN Design and Deployment Guide

Virtual SAN Design and Deployment Guide Virtual SAN Design and Deployment Guide TECHNICAL MARKETING DOCUMENTATION VERSION 1.3 - November 2014 Copyright 2014 DataCore Software All Rights Reserved Table of Contents INTRODUCTION... 3 1.1 DataCore

More information

EMC VPLEX FAMILY. Continuous Availability and data Mobility Within and Across Data Centers

EMC VPLEX FAMILY. Continuous Availability and data Mobility Within and Across Data Centers EMC VPLEX FAMILY Continuous Availability and data Mobility Within and Across Data Centers DELIVERING CONTINUOUS AVAILABILITY AND DATA MOBILITY FOR MISSION CRITICAL APPLICATIONS Storage infrastructure is

More information

CONTINUOUS DATA PROTECTION FOR MICROSOFT SQL SERVER 2008 R2 ENABLED BY EMC RECOVERPOINT, EMC REPLICATION MANAGER, AND VMWARE

CONTINUOUS DATA PROTECTION FOR MICROSOFT SQL SERVER 2008 R2 ENABLED BY EMC RECOVERPOINT, EMC REPLICATION MANAGER, AND VMWARE White Paper CONTINUOUS DATA PROTECTION FOR MICROSOFT SQL SERVER 2008 R2 ENABLED BY EMC RECOVERPOINT, EMC REPLICATION MANAGER, AND VMWARE A Detailed Review EMC SOLUTIONS GROUP Abstract This white paper

More information

Data Centre of the Future

Data Centre of the Future Data Centre of the Future Vblock Infrastructure Packages: Accelerating Deployment of the Private Cloud Andrew Smallridge DC Technology Solutions Architect asmallri@cisco.com 1 IT is undergoing a transformation

More information

Reference Architecture. EMC Global Solutions. 42 South Street Hopkinton MA 01748-9103 1.508.435.1000 www.emc.com

Reference Architecture. EMC Global Solutions. 42 South Street Hopkinton MA 01748-9103 1.508.435.1000 www.emc.com EMC Backup and Recovery for SAP with IBM DB2 on IBM AIX Enabled by EMC Symmetrix DMX-4, EMC CLARiiON CX3, EMC Replication Manager, IBM Tivoli Storage Manager, and EMC NetWorker Reference Architecture EMC

More information

TOP FIVE REASONS WHY CUSTOMERS USE EMC AND VMWARE TO VIRTUALIZE ORACLE ENVIRONMENTS

TOP FIVE REASONS WHY CUSTOMERS USE EMC AND VMWARE TO VIRTUALIZE ORACLE ENVIRONMENTS TOP FIVE REASONS WHY CUSTOMERS USE EMC AND VMWARE TO VIRTUALIZE ORACLE ENVIRONMENTS Leverage EMC and VMware To Improve The Return On Your Oracle Investment ESSENTIALS Better Performance At Lower Cost Run

More information

EMC BUSINESS RECOVERY SOLUTION FOR MEDITECH

EMC BUSINESS RECOVERY SOLUTION FOR MEDITECH White Paper EMC BUSINESS RECOVERY SOLUTION FOR MEDITECH VMware vsphere, EMC VMAXe, Data Domain, NetWorker NMMEDI, FAST VP, Faster backup and recovery of MEDITECH Client Server 6.0 in minutes or hours,

More information

EMC BACKUP-AS-A-SERVICE

EMC BACKUP-AS-A-SERVICE Reference Architecture EMC BACKUP-AS-A-SERVICE EMC AVAMAR, EMC DATA PROTECTION ADVISOR, AND EMC HOMEBASE Deliver backup services for cloud and traditional hosted environments Reduce storage space and increase

More information

EMC VPLEX FAMILY. Continuous Availability and Data Mobility Within and Across Data Centers

EMC VPLEX FAMILY. Continuous Availability and Data Mobility Within and Across Data Centers EMC VPLEX FAMILY Continuous Availability and Data Mobility Within and Across Data Centers DELIVERING CONTINUOUS AVAILABILITY AND DATA MOBILITY FOR MISSION CRITICAL APPLICATIONS Storage infrastructure is

More information

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, VMware vcenter Converter A Detailed Review EMC Information Infrastructure Solutions Abstract This white paper

More information

www.vce.com SAP Landscape Virtualization Management Version 2.0 on VCE Vblock System 700 series

www.vce.com SAP Landscape Virtualization Management Version 2.0 on VCE Vblock System 700 series www.vce.com SAP Landscape Virtualization Management Version 2.0 on VCE Vblock System 700 series Version 1.1 December 2014 THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." VCE MAKES NO REPRESENTATIONS

More information

EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage

EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage Applied Technology Abstract This white paper describes various backup and recovery solutions available for SQL

More information

HBA Virtualization Technologies for Windows OS Environments

HBA Virtualization Technologies for Windows OS Environments HBA Virtualization Technologies for Windows OS Environments FC HBA Virtualization Keeping Pace with Virtualized Data Centers Executive Summary Today, Microsoft offers Virtual Server 2005 R2, a software

More information

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4 Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4 Application Note Abstract This application note explains the configure details of using Infortrend FC-host storage systems

More information

Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server

Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server How to deploy Converged Networking with VMware ESX Server 3.5 Using Emulex FCoE Technology Table of Contents Introduction...

More information

White Paper. SAP NetWeaver Landscape Virtualization Management on VCE Vblock System 300 Family

White Paper. SAP NetWeaver Landscape Virtualization Management on VCE Vblock System 300 Family White Paper SAP NetWeaver Landscape Virtualization Management on VCE Vblock System 300 Family Table of Contents 2 Introduction 3 A Best-of-Breed Integrated Operations Architecture 3 SAP NetWeaver Landscape

More information

Module: Business Continuity

Module: Business Continuity Upon completion of this module, you should be able to: Describe business continuity and cloud service availability Describe fault tolerance mechanisms for cloud infrastructure Discuss data protection solutions

More information

DR-to-the- Cloud Best Practices

DR-to-the- Cloud Best Practices DR-to-the- Cloud Best Practices HOW TO EFFECTIVELY CONFIGURE YOUR OWN SELF-MANAGED RECOVERY PLANS AND THE REPLICATION OF CRITICAL VMWARE VIRTUAL MACHINES FROM ON-PREMISES TO A CLOUD SERVICE PROVIDER CONTENTS

More information

Microsoft SQL Server 2005 on Windows Server 2003

Microsoft SQL Server 2005 on Windows Server 2003 EMC Backup and Recovery for SAP Microsoft SQL Server 2005 on Windows Server 2003 Enabled by EMC CLARiiON CX3, EMC Disk Library, EMC Replication Manager, EMC NetWorker, and Symantec Veritas NetBackup Reference

More information

VMware Site Recovery Manager with EMC RecoverPoint

VMware Site Recovery Manager with EMC RecoverPoint VMware Site Recovery Manager with EMC RecoverPoint Implementation Guide EMC Global Solutions Centers EMC Corporation Corporate Headquarters Hopkinton MA 01748-9103 1.508.435.1000 www.emc.com Copyright

More information

A Platform Built for Server Virtualization: Cisco Unified Computing System

A Platform Built for Server Virtualization: Cisco Unified Computing System A Platform Built for Server Virtualization: Cisco Unified Computing System What You Will Learn This document discusses how the core features of the Cisco Unified Computing System contribute to the ease

More information

EMC Replication Manager for Virtualized Environments

EMC Replication Manager for Virtualized Environments EMC Replication Manager for Virtualized Environments A Detailed Review Abstract Today s IT organization is constantly looking for ways to increase the efficiency of valuable computing resources. Increased

More information

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine

How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine Virtual Fibre Channel for Hyper-V Virtual Fibre Channel for Hyper-V, a new technology available in Microsoft Windows Server 2012, allows direct access to Fibre Channel (FC) shared storage by multiple guest

More information

BUSINESS CONTINUITY AND DISASTER RECOVERY FOR ORACLE 11g

BUSINESS CONTINUITY AND DISASTER RECOVERY FOR ORACLE 11g BUSINESS CONTINUITY AND DISASTER RECOVERY FOR ORACLE 11g ENABLED BY EMC VMAX 10K AND EMC RECOVERPOINT Technical Presentation EMC Solutions Group 1 Agenda Business case Symmetrix VMAX 10K overview RecoverPoint

More information

EMC MID-RANGE STORAGE AND THE MICROSOFT SQL SERVER I/O RELIABILITY PROGRAM

EMC MID-RANGE STORAGE AND THE MICROSOFT SQL SERVER I/O RELIABILITY PROGRAM White Paper EMC MID-RANGE STORAGE AND THE MICROSOFT SQL SERVER I/O RELIABILITY PROGRAM Abstract This white paper explains the integration of EMC Mid-range Storage arrays with the Microsoft SQL Server I/O

More information

Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study

Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study White Paper Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study 2012 Cisco and/or its affiliates. All rights reserved. This

More information

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution EMC Virtual Infrastructure for Microsoft Applications Data Center Solution Enabled by EMC Symmetrix V-Max and Reference Architecture EMC Global Solutions Copyright and Trademark Information Copyright 2009

More information

EMC MIGRATION OF AN ORACLE DATA WAREHOUSE

EMC MIGRATION OF AN ORACLE DATA WAREHOUSE EMC MIGRATION OF AN ORACLE DATA WAREHOUSE EMC Symmetrix VMAX, Virtual Improve storage space utilization Simplify storage management with Virtual Provisioning Designed for enterprise customers EMC Solutions

More information

IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology

IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology White Paper IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology Abstract EMC RecoverPoint provides full support for data replication and disaster recovery for VMware ESX Server

More information

VMware Virtual Machine File System: Technical Overview and Best Practices

VMware Virtual Machine File System: Technical Overview and Best Practices VMware Virtual Machine File System: Technical Overview and Best Practices A VMware Technical White Paper Version 1.0. VMware Virtual Machine File System: Technical Overview and Best Practices Paper Number:

More information

Evaluation of Enterprise Data Protection using SEP Software

Evaluation of Enterprise Data Protection using SEP Software Test Validation Test Validation - SEP sesam Enterprise Backup Software Evaluation of Enterprise Data Protection using SEP Software Author:... Enabling you to make the best technology decisions Backup &

More information

VMware Virtual SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014

VMware Virtual SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014 VMware SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014 VMware SAN Backup Using VMware vsphere Table of Contents Introduction.... 3 vsphere Architectural Overview... 4 SAN Backup

More information

Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture. Dell Compellent Product Specialist Team

Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture. Dell Compellent Product Specialist Team Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture Dell Compellent Product Specialist Team THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL

More information

MAXIMIZING AVAILABILITY OF MICROSOFT SQL SERVER 2012 ON VBLOCK SYSTEMS

MAXIMIZING AVAILABILITY OF MICROSOFT SQL SERVER 2012 ON VBLOCK SYSTEMS Maximizing Availability of Microsoft SQL Server 2012 on Vblock Systems Table of Contents www.vce.com MAXIMIZING AVAILABILITY OF MICROSOFT SQL SERVER 2012 ON VBLOCK SYSTEMS January 2013 1 Contents Introduction...4

More information

Configuration Maximums

Configuration Maximums Topic Configuration s VMware vsphere 5.1 When you select and configure your virtual and physical equipment, you must stay at or below the maximums supported by vsphere 5.1. The limits presented in the

More information

VBLOCK SYSTEMS: ENHANCED OPERATIONAL AGILITY AND SCALABILITY FOR ORACLE E-BUSINESS SUITE R12 AND RAC ON VMWARE VSPHERE 5

VBLOCK SYSTEMS: ENHANCED OPERATIONAL AGILITY AND SCALABILITY FOR ORACLE E-BUSINESS SUITE R12 AND RAC ON VMWARE VSPHERE 5 Enhanced Operational Agility and Scalability for Oracle E- Business Suite R12 and RAC on VMware vsphere 5 Table of Contents www.vce.com VBLOCK SYSTEMS: ENHANCED OPERATIONAL AGILITY AND SCALABILITY FOR

More information

MANAGEMENT AND ORCHESTRATION WORKFLOW AUTOMATION FOR VBLOCK INFRASTRUCTURE PLATFORMS

MANAGEMENT AND ORCHESTRATION WORKFLOW AUTOMATION FOR VBLOCK INFRASTRUCTURE PLATFORMS VCE Word Template Table of Contents www.vce.com MANAGEMENT AND ORCHESTRATION WORKFLOW AUTOMATION FOR VBLOCK INFRASTRUCTURE PLATFORMS January 2012 VCE Authors: Changbin Gong: Lead Solution Architect Michael

More information

VBLOCK SOLUTION FOR KNOWLEDGE WORKER ENVIRONMENTS WITH VMWARE VIEW 4.5

VBLOCK SOLUTION FOR KNOWLEDGE WORKER ENVIRONMENTS WITH VMWARE VIEW 4.5 Table of Contents www.vce.com VBLOCK SOLUTION FOR KNOWLEDGE WORKER ENVIRONMENTS WITH VMWARE VIEW 4.5 Version 2.0 February 2013 1 Copyright 2013 VCE Company, LLC. All Rights Reserved.

More information

Using VMWare VAAI for storage integration with Infortrend EonStor DS G7i

Using VMWare VAAI for storage integration with Infortrend EonStor DS G7i Using VMWare VAAI for storage integration with Infortrend EonStor DS G7i Application Note Abstract: This document describes how VMware s vsphere Storage APIs (VAAI) can be integrated and used for accelerating

More information

SAP Solutions on VMware Infrastructure 3: Customer Implementation - Technical Case Study

SAP Solutions on VMware Infrastructure 3: Customer Implementation - Technical Case Study SAP Solutions on VMware Infrastructure 3: Table of Contents Introduction... 1 SAP Solutions Based Landscape... 1 Logical Architecture... 2 Storage Configuration... 3 Oracle Database LUN Layout... 3 Operations...

More information

Virtualization, Business Continuation Plan & Disaster Recovery for EMS -By Ramanj Pamidi San Diego Gas & Electric

Virtualization, Business Continuation Plan & Disaster Recovery for EMS -By Ramanj Pamidi San Diego Gas & Electric Virtualization, Business Continuation Plan & Disaster Recovery for EMS -By Ramanj Pamidi San Diego Gas & Electric 2001 San Diego Gas and Electric. All copyright and trademark rights reserved. Importance

More information

Implementing and Troubleshooting the Cisco Cloud Infrastructure **Part of CCNP Cloud Certification Track**

Implementing and Troubleshooting the Cisco Cloud Infrastructure **Part of CCNP Cloud Certification Track** Course: Duration: Price: $ 4,295.00 Learning Credits: 43 Certification: Implementing and Troubleshooting the Cisco Cloud Infrastructure Implementing and Troubleshooting the Cisco Cloud Infrastructure**Part

More information

EMC MISSION-CRITICAL BUSINESS CONTINUITY AND DISASTER RECOVERY FOR ORACLE EXTENDED RAC

EMC MISSION-CRITICAL BUSINESS CONTINUITY AND DISASTER RECOVERY FOR ORACLE EXTENDED RAC White Paper EMC MISSION-CRITICAL BUSINESS CONTINUITY AND DISASTER RECOVERY FOR ORACLE EXTENDED RAC EMC VPLEX, EMC RecoverPoint, EMC VMAX, EMC VNX, Brocade Networking Simplified management for high availability,

More information

Dell PowerVault MD32xx Deployment Guide for VMware ESX4.1 Server

Dell PowerVault MD32xx Deployment Guide for VMware ESX4.1 Server Dell PowerVault MD32xx Deployment Guide for VMware ESX4.1 Server A Dell Technical White Paper PowerVault MD32xx Storage Array www.dell.com/md32xx THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND

More information

Continuous Data Protection for any Point-in-Time Recovery: Product Options for Protecting Virtual Machines or Storage Array LUNs

Continuous Data Protection for any Point-in-Time Recovery: Product Options for Protecting Virtual Machines or Storage Array LUNs EMC RECOVERPOINT FAMILY Continuous Data Protection for any Point-in-Time Recovery: Product Options for Protecting Virtual Machines or Storage Array LUNs ESSENTIALS EMC RecoverPoint Family Optimizes RPO

More information

DVS Enterprise. Reference Architecture. VMware Horizon View Reference

DVS Enterprise. Reference Architecture. VMware Horizon View Reference DVS Enterprise Reference Architecture VMware Horizon View Reference THIS DOCUMENT IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED

More information

Setup for Failover Clustering and Microsoft Cluster Service

Setup for Failover Clustering and Microsoft Cluster Service Setup for Failover Clustering and Microsoft Cluster Service ESX 4.0 ESXi 4.0 vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the

More information

CONFIGURATION BEST PRACTICES FOR MICROSOFT SQL SERVER AND EMC SYMMETRIX VMAXe

CONFIGURATION BEST PRACTICES FOR MICROSOFT SQL SERVER AND EMC SYMMETRIX VMAXe White Paper CONFIGURATION BEST PRACTICES FOR MICROSOFT SQL SERVER AND EMC SYMMETRIX VMAXe Simplified configuration, deployment, and management for Microsoft SQL Server on Symmetrix VMAXe Abstract This

More information

EXCHANGE 2010 DISASTER RECOVERY OPTIONS WITH CROSS-SITE EXCHANGE DAG AND EMC RECOVERPOINT

EXCHANGE 2010 DISASTER RECOVERY OPTIONS WITH CROSS-SITE EXCHANGE DAG AND EMC RECOVERPOINT White Paper EXCHANGE 2010 DISASTER RECOVERY OPTIONS WITH CROSS-SITE EXCHANGE DAG AND EMC RECOVERPOINT A Detailed Review EMC GLOBAL SOLUTIONS Abstract This white paper provides analysis, data points and

More information

Backup and Recovery with Cisco UCS Solutions for SAP HANA

Backup and Recovery with Cisco UCS Solutions for SAP HANA Configuration Guide Backup and Recovery with Cisco UCS Solutions for SAP HANA Configuration Guide March, 2014 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page

More information

Microsoft Exchange Solutions on VMware

Microsoft Exchange Solutions on VMware Design and Sizing Examples: Microsoft Exchange Solutions on VMware Page 1 of 19 Contents 1. Introduction... 3 1.1. Overview... 3 1.2. Benefits of Running Exchange Server 2007 on VMware Infrastructure 3...

More information

EMC Business Continuity and Disaster Recovery Solutions

EMC Business Continuity and Disaster Recovery Solutions EMC Business Continuity and Disaster Recovery Solutions Comprehensive Data Protection Rick Walsworth Director, Product Marketing EMC Cross Platform Replication 1 Agenda Data Protection Challenges EMC Continuity

More information

Veritas Storage Foundation High Availability for Windows by Symantec

Veritas Storage Foundation High Availability for Windows by Symantec Veritas Storage Foundation High Availability for Windows by Symantec Simple-to-use solution for high availability and disaster recovery of businesscritical Windows applications Data Sheet: High Availability

More information

High Availability with Windows Server 2012 Release Candidate

High Availability with Windows Server 2012 Release Candidate High Availability with Windows Server 2012 Release Candidate Windows Server 2012 Release Candidate (RC) delivers innovative new capabilities that enable you to build dynamic storage and availability solutions

More information

EMC DATA PROTECTION FOR SAP HANA

EMC DATA PROTECTION FOR SAP HANA White Paper EMC DATA PROTECTION FOR SAP HANA Persistence, Disaster Tolerance, Disaster Recovery, and Efficient Backup for a Data Center Ready SAP HANA EMC Solutions Group Abstract This white paper explains

More information

Optimized Storage Solution for Enterprise Scale Hyper-V Deployments

Optimized Storage Solution for Enterprise Scale Hyper-V Deployments Optimized Storage Solution for Enterprise Scale Hyper-V Deployments End-to-End Storage Solution Enabled by Sanbolic Melio FS and LaScala Software and EMC SAN Solutions Proof of Concept Published: March

More information

Solution Brief Availability and Recovery Options: Microsoft Exchange Solutions on VMware

Solution Brief Availability and Recovery Options: Microsoft Exchange Solutions on VMware Introduction By leveraging the inherent benefits of a virtualization based platform, a Microsoft Exchange Server 2007 deployment on VMware Infrastructure 3 offers a variety of availability and recovery

More information

Optimizing Large Arrays with StoneFly Storage Concentrators

Optimizing Large Arrays with StoneFly Storage Concentrators Optimizing Large Arrays with StoneFly Storage Concentrators All trademark names are the property of their respective companies. This publication contains opinions of which are subject to change from time

More information

Direct Attached Storage

Direct Attached Storage , page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel

More information

Server and Storage Virtualization with IP Storage. David Dale, NetApp

Server and Storage Virtualization with IP Storage. David Dale, NetApp Server and Storage Virtualization with IP Storage David Dale, NetApp SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individuals may use this

More information

EMC Backup and Recovery for Microsoft SQL Server

EMC Backup and Recovery for Microsoft SQL Server EMC Backup and Recovery for Microsoft SQL Server Enabled by Quest LiteSpeed Copyright 2010 EMC Corporation. All rights reserved. Published February, 2010 EMC believes the information in this publication

More information

Vblock Infrastructure Platforms 2010 Vblock Platforms Architecture Overview

Vblock Infrastructure Platforms 2010 Vblock Platforms Architecture Overview www.vce.com Vblock Infrastructure Platforms 2010 Vblock Platforms Version 1.3 November 2011 2011 VE ompany, LL. All Rights Reserved. Revision history Revision history Date Version Author Description of

More information

W H I T E P A P E R. VMware Infrastructure Architecture Overview

W H I T E P A P E R. VMware Infrastructure Architecture Overview W H I T E P A P E R ware Infrastructure Architecture Overview ware white paper Table of Contents Physical Topology of the ware Infrastructure Data Center............................... 4 Virtual Data Center

More information

Oracle Database Scalability in VMware ESX VMware ESX 3.5

Oracle Database Scalability in VMware ESX VMware ESX 3.5 Performance Study Oracle Database Scalability in VMware ESX VMware ESX 3.5 Database applications running on individual physical servers represent a large consolidation opportunity. However enterprises

More information

Workload Resiliency with EMC VPLEX

Workload Resiliency with EMC VPLEX Best Practices Planning Abstract This white paper provides a brief introduction to EMC VPLEX and describes how VPLEX provides increased workload resiliency to the data center. Best practice recommendations

More information

VCE Vision Intelligent Operations Version 2.5 Technical Overview

VCE Vision Intelligent Operations Version 2.5 Technical Overview Revision history www.vce.com VCE Vision Intelligent Operations Version 2.5 Technical Document revision 2.0 March 2014 2014 VCE Company, 1 LLC. Revision history VCE Vision Intelligent Operations Version

More information

Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters

Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters Highlights a Brocade-EMC solution with EMC CLARiiON, EMC Atmos, Brocade Fibre Channel (FC) switches, Brocade FC HBAs, and Brocade

More information

Achieve Automated, End-to-End Firmware Management with Cisco UCS Manager

Achieve Automated, End-to-End Firmware Management with Cisco UCS Manager Achieve Automated, End-to-End Firmware Management with Cisco UCS Manager What You Will Learn This document describes the operational benefits and advantages of firmware provisioning with Cisco UCS Manager

More information

EMC Business Continuity for Microsoft SQL Server 2008

EMC Business Continuity for Microsoft SQL Server 2008 EMC Business Continuity for Microsoft SQL Server 2008 Enabled by EMC Symmetrix V-Max with SRDF/CE, EMC Replication Manager, and Enterprise Flash Drives Reference Architecture Copyright 2009 EMC Corporation.

More information

STORAGE CENTER. The Industry s Only SAN with Automated Tiered Storage STORAGE CENTER

STORAGE CENTER. The Industry s Only SAN with Automated Tiered Storage STORAGE CENTER STORAGE CENTER DATASHEET STORAGE CENTER Go Beyond the Boundaries of Traditional Storage Systems Today s storage vendors promise to reduce the amount of time and money companies spend on storage but instead

More information

VIDEO SURVEILLANCE WITH SURVEILLUS VMS AND EMC ISILON STORAGE ARRAYS

VIDEO SURVEILLANCE WITH SURVEILLUS VMS AND EMC ISILON STORAGE ARRAYS VIDEO SURVEILLANCE WITH SURVEILLUS VMS AND EMC ISILON STORAGE ARRAYS Successfully configure all solution components Use VMS at the required bandwidth for NAS storage Meet the bandwidth demands of a 2,200

More information

HIGHLY AVAILABLE MULTI-DATA CENTER WINDOWS SERVER SOLUTIONS USING EMC VPLEX METRO AND SANBOLIC MELIO 2010

HIGHLY AVAILABLE MULTI-DATA CENTER WINDOWS SERVER SOLUTIONS USING EMC VPLEX METRO AND SANBOLIC MELIO 2010 White Paper HIGHLY AVAILABLE MULTI-DATA CENTER WINDOWS SERVER SOLUTIONS USING EMC VPLEX METRO AND SANBOLIC MELIO 2010 Abstract This white paper demonstrates key functionality demonstrated in a lab environment

More information

VBLOCK TM INFRASTRUCTURE PLATFORMS: A TECHNICAL OVERVIEW

VBLOCK TM INFRASTRUCTURE PLATFORMS: A TECHNICAL OVERVIEW VBLOCK TM INFRASTRUCTURE PLATFORMS: A TECHNICAL OVERVIEW Executive Summary Cloud computing provides a flexible, shared pool of preconfigured and integrated computing resources that enables organizations

More information

Private cloud computing advances

Private cloud computing advances Building robust private cloud services infrastructures By Brian Gautreau and Gong Wang Private clouds optimize utilization and management of IT resources to heighten availability. Microsoft Private Cloud

More information

Microsoft SharePoint 2010 on VMware Availability and Recovery Options. Microsoft SharePoint 2010 on VMware Availability and Recovery Options

Microsoft SharePoint 2010 on VMware Availability and Recovery Options. Microsoft SharePoint 2010 on VMware Availability and Recovery Options This product is protected by U.S. and international copyright and intellectual property laws. This product is covered by one or more patents listed at http://www.vmware.com/download/patents.html. VMware

More information

Vblock Systems hybrid-cloud with Cisco Intercloud Fabric

Vblock Systems hybrid-cloud with Cisco Intercloud Fabric www.vce.com Vblock Systems hybrid-cloud with Cisco Intercloud Fabric Version 1.0 April 2015 THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." VCE MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND

More information

VMware vsphere 5.1 Advanced Administration

VMware vsphere 5.1 Advanced Administration Course ID VMW200 VMware vsphere 5.1 Advanced Administration Course Description This powerful 5-day 10hr/day class is an intensive introduction to VMware vsphere 5.0 including VMware ESX 5.0 and vcenter.

More information

High-Availability Fault Tolerant Computing for Remote and Branch Offices HA/FT solutions for Cisco UCS E-Series servers and VMware vsphere

High-Availability Fault Tolerant Computing for Remote and Branch Offices HA/FT solutions for Cisco UCS E-Series servers and VMware vsphere Table of Contents UCS E-Series Availability and Fault Tolerance... 3 Solid hardware... 3 Consistent management... 3 VMware vsphere HA and FT... 3 Storage High Availability and Fault Tolerance... 4 Quick-start

More information

Solution Overview 4 Layers...2. Layer 1: VMware Infrastructure 3...2. Components of the VMware infrastructure...2

Solution Overview 4 Layers...2. Layer 1: VMware Infrastructure 3...2. Components of the VMware infrastructure...2 Contents Overview...1 Key Implementation Challenges...1 Providing a Solution through Virtualization...1 Benefits of Running SQL Server with VMware Infrastructure...1 Solution Overview 4 Layers...2 Layer

More information