Document Commercial Commercial Document
|
|
|
- Suzanna McDonald
- 10 years ago
- Views:
Transcription
1 Document Commercial Commercial Document DC.QUAL.001 Declaration of CE conformity - Déclaration de conformité CE CE conformiteitverklaring - CE Konformitätserklärung GEL 22/04/2015 Added FUFLEX 825, 826 (10 & 16mm), FU.PAR2.002 (ATEX) BDK 05 GEL 14/04/2015 Added FUFLEX (10 & 16mm, ATEX & not-atex), FUTTSExxxx JPE 04 BDK+GEL 12/12/2014 New layout RBT 03 JPD 16/04/2013 Suppressed EN GEL 02 JPD 06/03/2013 General review GEL 01 JPD 12/12/2012 Original ADG Ver. Author Nature of modification Verified DC.QUAL Declarations_of_CE_CONFORMITY.docx 1/10
2 CONTENTS Code. Article-nr. Artikel-Nr Description Beschrijving - Beschreibung SDT index page FUFLUS-01, -02 FLEX.US Receiver, SKF TMSU 1 2, 3, 4, 9 3 FUR170 SDT170 Receiver FUSHER SHERLOG Receiver FUFLEX555, 556 Flexible Sensor 550mm BNC with removable Sensor 10mm, 16mm FUFLEX825, 826 Flexible Sensor 820mm BNC with removable Sensor 10mm, 16mm 2, 3, 4 4 FUSCRS3 Threaded sensor RS1T FUSOND270 RS1N Needle contact probe FUT008 SDT8 Transmitter FUR200 SDT200 Receiver FURBLOK BLOCK Steam detect receiver 2, 3, 4, 5, 9 5 FUR270 SDT270 Receiver FUR200A SDT200 ATEX Receiver FURBLOKA BLOCK Steam detect ATEX receiver 2, 3, 4, 5, 6 FUR270A SDT270 ATEX Receiver 6, 7, 8, 9 FU.PAR2.002 ParaDish2 Parabolic sensor ATEX FUSOND270A RS1N Needle contact probe ATEX FUFLEXEX1 Flexible Sens. ATEX 550mm W/ removable Sensor 16 mm & Ext 2, 3, 4, 6, 7, 8 7 FUFLEXEX2 Flexible Sens. ATEX 550mm W/ removable Sensor 10 mm & Ext FUSCRS3A Threaded sensor RS1T ATEX FUPARA25 ParaDish1 Parabolic sensor 2, 3, 4, 5 8 FU.PAR2.001 ParaDish2 Parabolic sensor FUTTSExxxx Sensor Tank Test ATEX 2, 6, 7, 8 9 FUPWSPUN, 01 Universal battery charger SDT 1, 2, 3, 4 10 DC.QUAL Declarations_of_CE_CONFORMITY.docx 2/10
3 MANUFACTURER S DECLARATION OF CONFORMITY «CE» (conform to ISO ) 415 Boulevard de l Humanité B-1190 Brussels FUFLUS-01 FUFLUS-02 FLEX.US Receiver SKF TMSU 1 Ultrasonic Leak Detector 3 EN :1995 Electromagnetic compatibility (EMC) Part 4-2 Electrostatic discharge immunity test 4 EN :2002 Electromagnetic compatibility (EMC) Part 4-3 Radiated, radio 9 EN 61326:2006 Electrical equipment for measurement, control and laboratory use, EMC requirements - Part 1: General requirements DC.QUAL Declarations_of_CE_CONFORMITY.docx 3/10
4 415 Boulevard de l Humanité B-1190 Brussels FUR170 FUSHER FUFLEX555 FUFLEX556 FUFLEX855 FUFLEX856 FUSCRS3 FUSOND270 FUT008 SDT170 Receiver SHERLOG Receiver Flexible Sensor 550mm BNC with removable Sensor 10 mm Flexible Sensor 550mm BNC with removable Sensor 16 mm Flexible Sensor 820mm BNC with removable Sensor 10 mm Flexible Sensor 820mm BNC with removable Sensor 16 mm Threaded sensor RS1T RS1N Needle contact probe SDT8 Transmitter 3 EN :1995 Electromagnetic compatibility(emc) Part 4-2 Electrostatic discharge immunity test 4 EN :2002 Electromagnetic compatibility(emc) Part 4-3 Radiated, radio DC.QUAL Declarations_of_CE_CONFORMITY.docx 4/10
5 415 Boulevard de l Humanité B-1190 Brussels FUR200 FURBLOK FUR270 SDT200 Receiver BLOCK Steam detect receiver SDT270 Receiver Standards applied Normes appliquées - De normen van toepassing zijn Normen : 3 EN :1995 Electromagnetic compatibility(emc) Part 4-2 Electrostatic discharge immunity test 4 EN :2002 Electromagnetic compatibility(emc) Part 4-3 Radiated, radio 5 EN :2007 Safety of laser products - Part 1: Equipment classification, requirements and user's guide 9 EN 61326:2006 Electrical equipment for measurement, control and laboratory use, EMC requirements - Part 1: General requirements DC.QUAL Declarations_of_CE_CONFORMITY.docx 5/10
6 415 Boulevard de l Humanité B-1190 Brussels FUR200A FURBLOKA FUR270A FU.PAR2.002 SDT200 ATEX Receiver BLOCK Steam detect ATEX receiver SDT270 ATEX Receiver ParaDish2 Parabolic Sensor ATEX 94/9/EC ATEX Directive 3 EN :1995 Electromagnetic compatibility (EMC) Part 4-2 Electrostatic discharge immunity test 4 EN :2002 Electromagnetic compatibility (EMC) Part 4-3 Radiated, radio 5 EN :2007 Safety of laser products - Part 1: Equipment classification, requirements and user's guide 6 EN :2007 Explosive atmospheres General requirements 7 EN :2006 Explosive atmospheres Equipment protection by intrinsic safety i 8 EN :2004 Explosive atmospheres Construction, test and marking of Group II Zone 0 electrical apparatus. 9 EN :2006 Electrical equipment for measurement, control and laboratory use, EMC requirements - Part 1: General requirements DC.QUAL Declarations_of_CE_CONFORMITY.docx 6/10
7 415, Boulevard de l Humanité B Brussels FUSOND270A FUFLEXEX1 FUFLEXEX2 FUSCRS3A RS1N Needle contact probe ATEX Flexible Sens. ATEX 550mm W/ removable Sensor 16mm & Ext Flexible Sens. ATEX 550mm W/ removable Sensor 10mm & Ext Threaded sensor RS1T ATEX 94/9/EC ATEX Directive 3 EN :1995 Electromagnetic compatibility(emc) Part 4-2 Electrostatic discharge immunity test 4 EN :2002 Electromagnetic compatibility (EMC) Part 4-3 Radiated, radio 6 EN :2007 Explosive atmospheres General requirements 7 EN :2006 Explosive atmospheres Equipment protection by intrinsic safety i 8 EN :2004 Explosive atmospheres Construction, test and marking of Group II Zone 0 electrical apparatus. DC.QUAL Declarations_of_CE_CONFORMITY.docx 7/10
8 , 415 Boulevard de l Humanité, B-1190 Brussels, FUPARA25 FU.PAR2.001 Parabolic sensor Paradish1. Parabol Sonde Paradish1. Parabolic sensor Paradish2. Parabol Sonde Paradish2.. Directive Basse Tension (DBT). Laagspanningsrichtlijn. Niederspannungsrichtline.. Directive Compatibilité Electromagnétique (CEM). Electromagnetic Compatibility (EMC) Richtlein. Elektromagnetische Vertäglichkeit (EMV) Direkitve. Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regelund Laborgeräte - Teil 1: Allgemeine Anforderungen 3 EN :1995 Electromagnetic compatibility (EMC) Part 4-2 Electrostatic discharge immunity test. Elektromagnetische Verträglichkeit (EMV) Teil 4-2 Störfestigkeit gegen elektrostatische Entladungen. 4 EN :2002 Electromagnetic compatibility (EMC) Part 4-3 Radiated, radio Elektromagnetische Verträglichkeit (EMV) Teil 4-3 Störfestigkeit, Radiofrequenz, Störfestigkeit gegenüber elektromagnetischen Feldern. 5 EN :2007 Safety of laser products Part 1: Equipment classification, requirements and user's guide. Sicherheit von Lasereinrichtungen Teil 1: Klassifizierung von Anlagen, Anforderungen und Benutzer-Richtlinien. April 14, 2015, André DEGRAEVE, Managing Director, Geschäftsführer DC.QUAL Declarations_of_CE_CONFORMITY.docx 8/10
9 , 415 Boulevard de l Humanité, B-1190 Brussels, FUTTSExxxx Sensor TankTest ATEX 94/9/EC. Directive Basse Tension (DBT). Laagspanningsrichtlijn. Niederspannungsrichtline. ATEX Directive Directive ATEX Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel-und Laborgeräte - Teil 1: Allgemeine Anforderungen 6 EN :2012 Explosive atmospheres General requirements 7 EN :2012 Explosive atmospheres Equipment protection by intrinsic safety i 8 EN :2007 Explosive atmospheres Equipment with equipment protection level (EPL) Ga DC.QUAL Declarations_of_CE_CONFORMITY.docx 9/10
10 415 Boulevard de l Humanité B-1190 Brussels FUPWSPUN-01 Universal battery charger SDT 1 EN :2005 Information technology equipment - Safety Part 1: General requirements 3 EN :1995 Electromagnetic compatibility (EMC) Part 4-2 Electrostatic discharge immunity test 4 EN :2002 Electromagnetic compatibility (EMC) Part 4-3 Radiated, radio DC.QUAL Declarations_of_CE_CONFORMITY.docx 10/10
Phone : 0043 3462 2541-100 Fax: +0043 3462 2541-310 e-mail: [email protected]
Anschrift / Address / Adresse / Indirizzo Fabbricante/Persona responsabile Fabricant/Personne responsable declare que le produit Type (ggf. Anlagenkonfiguration mit Angabe der Module): Type (if applicable,
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
Gas Detector System, Portable/Fixed Oxygen Analysis and Gas Detection Equipment
STANDARD FOR CERTIFICATION No. 2.9 TYPE APPROVAL PROGRAMME NO. 7-473.30/31 / MED A.1/3.30/54 Gas Detector System, Portable/Fixed Oxygen Analysis and Gas Detection Equipment SEPTEMBER 2011 The content of
Operating instructions Supply system for flammable liquids. Labor
Operating instructions Supply system for flammable liquids Labor Table of contents Safety General safety instructions.................... 2 Warning instructions used in this operating instruction 3 Correct
Telemetrie-Messtechnik Schnorrenberg
Telemetrie-Messtechnik Schnorrenberg T1-PCM-BATT Digital Telemetry System for Strain Gage Applications on Rotating Shafts Operating Instructions Easy to assemble and operate Distance up to 150mm (Range)
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
ipc10 ipc20 Operating Instruction isel Germany AG, D-36124 Eichenzell, Bürgermeister-Ebert-Str. 40 (06659)981-0 (06659)981-776
ipc10 ipc20 Operating Instruction isel Germany AG, D-36124 Eichenzell, Bürgermeister-Ebert-Str. 40 (06659)981-0 (06659)981-776 The information, technical data and dimensions contained in this print have
Power in electrical safety Electrical safety for hybrid and electric vehicles
Power in electrical safety Electrical safety for hybrid and electric vehicles Bender Germany www.bender-de.com Draft H. Sellner 4 March 2009 No. 1 Overview 1. General 2. Drive concepts 3. Standards 4.
Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction
Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages.................................
with microprocessor program controller RD3 Service Hotline Asia Pacific +852 39070500 or +852 39070503 Service Hotline Russia and CIS +7 495 98815 17
Operating Manual APT.line KB (E5.1) Refrigerated Incubators with microprocessor program controller RD3 Model Art. No. KB 240 (E5.1) 9020-0162, 9120-0162 9020-0241, 9120-0241 KB 240-UL (E5.1) 9020-0163,
CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE
CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE of Product Name Model Brand Memorex; Imation; TDK Life on Record Contains: 1. Declaration of Conformity 2. EN55022/CISPR 22, AS/NZS CISPR 22 EMI test
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, UK. Tel: +44 (0)1527 406800 Fax:
EC-Declaration of Conformity Annex
2006/95/EC is given by the compliance with the following European Standard(s). If not EN 61347-1: + A1:2011 EN 61347-2-1. A1:2006 + Corrigendum:2006 EN 61347-2-2: 2012 EN 61347-2-3: 2011 EN 61347-2-7:
REGULATIONS CODES STANDARDS
HYDROGEN RCS: REGULATIONS CODES STANDARDS ITM POWER DESIGNS AND MANUFACTURES HYDROGEN ENERGY SYSTEMS FOR ENERGY STORAGE AND CLEAN FUEL PRODUCTION HYDROGEN RCS: REGULATIONS CODES STANDARDS Contents Introduction
IEC and CISPR Standards
IEC and CISPR Standards With thanks to Gideon Wiid, PhD student, and Paul van der Merwe EE Eng, 2 May, 2007 EMC Definition: Electromagnetic compatibility itself is defined as [1]: "the ability of an equipment
QFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
Additional Requirements
VdS Guidelines for Smoke Alarm Devices VdS 3131en Requirements and Test Methods VdS 3131en : 2010-05 (01) Publisher and publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 174 50735 Köln, Germany
LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring
LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions
Floodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
Overview of Standards for CO Detection Products
Overview of Standards for CO Detection Products Rev 1.1 INTEC Controls 12700 Stowe Dr., Suite 100 Poway, CA 92064 The Right Choice [email protected] www.inteccontrols.com Phone: (858) 578-7887 Fax:
The impact of the New EMC Directive 2004/108/EC
The impact of the New EMC Directive 2004/108/EC Presentation by Damon High Presentation Overview Brief overview of Electromagnetic Interference and Electromagnetic Compatibility EMC Directive and UK Legislation
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
Industrial trucks for use in potentially explosive areas - placing on the market in compliance with Directive 94/9/EC and EN 1755 1
Industrial trucks for use in potentially explosive areas - placing on the market in compliance with Directive 94/9/EC and EN 1755 1 Frank Neugebauer, Braunschweig Dirk-Hans Frobese, Braunschweig Industrial
ÖNORM EN 1643. Valve proving systems for automatic shut-off valves for gas burners and gas appliances
ÖNORM EN 1643 Edition: 2001-01-01 Standards groups H and M Identical (IDT) with ICS 23.060.20 Valve proving systems for automatic shut-off valves for gas burners and gas appliances Ventilüberwachungssysteme
HandyTone Analog Telephone Adapter Quick Installation Guide
HandyTone Analog Telephone Adapter Quick Installation Guide Part Number: 418-02010-10 Document Version Number: 1.0 Handytone 502 & HandyTone 503 HandyTone 286 & HandyTone 486 1 HandyTone Analog Telephone
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M Compact Operating Instructions Legal information Qualified Personnel The product/system described in this documentation
Hazardous Locations Training
Hazardous Locations Training If you are involved with projects associated with hazardous locations, which involves the installation or inspection and maintenance of electrical or non-electrical e.g. mechanical;
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
Smart Remote. with. QuickGuide
Smart Remote with QuickGuide 1 1 2 3 2 A B 3 A Connecting the remote control B Do not cover the microphone 1 Adjusting the volume Press the + or - button. 2 Controlling audio functions Press the button
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
Lockout Specification BW Clip Maintenance-free single gas detector
Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than
BudgeTone SIP Phone Quick Installation Guide
BudgeTone SIP Phone Quick Installation Guide Part Number:418-02001-10 Document Version Number:1.0 1 BudgeTone IP Phone Quick Installation Guide WARNING: Please DO NOT power cycle the phone during system
NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module
DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position
3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
Experience with taximeters with a look at the corresponding tables
Experience with taximeters with a look at the corresponding tables Milan Prasil CMI Laboratory of the fundamental metrology V Botanice 4, 150 72 Prague 5 [email protected] Taximeters in EU are subject to
Description. Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers
Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers R Description These accelerometers are intended for critical machinery applications where casing acceleration
How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab
How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab For questions and details contact Dennis at [email protected] Introduction The CE mark (an acronym for the French
MAVO-MONITOR USB. Page. 1 Applications... 2. 2 Display... 2 2.1 The elements of the display... 2 2.2 Key pad... 2
Operating Instructions MAVO-MONITOR USB Measuring Instrument for Luminance 15161 1/7.04 Light sensor USB Port Display Light measuring probe Key pad MAVO-MONITOR USB 1 Applications... 2 Page 2 Display...
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks
LED/Connector pin identification table AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks 3,4,5 pole XLR Male & Female 3,5 & 8 pole 180
Operating Instructions
Beuler Höhe 11, D-45525 Hattingen Tel. +49(0)2324/55515 [email protected] www.stephandahlmann.com Operating Instructions Contents Page 1. Designation and Illustration of the Machine 1 2. EC Declaration
Installation Instructions It is recommended to check the following points when receiving this product:
Serie HDT / HDB Ventiladores Helicoidales Axial Fans Ventilateurs Helicoïdes Axial-Ventilatoren Ventilatori elicoidali Exaustores elicoidais Axiaal ventilatoren Instrucciones de uso e instalación. / Instructions
CE Marking: Your Key to Entering the European Market
CE Marking: Your Key to Entering the European Market N. Gerard Zapiain U.S. Department of Commerce International Trade Administration Office of Microelectronics, Medical Equipment and Instrumentation I.
EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5
EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA
FGM 160 ATEX EC type examination certificate
Document number: 75.120.223 Document title: FGM 160 ATEX EC type examination certificate Scope: EN 60079-0, 1, 7, 11, 26 Additional Information (when applicable) F 2015.06.03 New certificate issue Nemko
What is ATEX? The European Regulatory Framework for Manufacture, Installation and Use of Equipment in Explosive Atmospheres
What is ATEX? The European Regulatory Framework for Manufacture, Installation and Use of Equipment in Explosive Atmospheres Ron Sinclair MBE Chair IECEx ExTAG ATEX? ATEX = Atmosphères Explosibles ATEX
The use of wireless technology in hazardous areas
>> Application Report The use of wireless technology in hazardous areas by Stephan Schultz Figure 1: Typical environment for the use of wireless solutions in the process industry Why radio transmission
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Electromagnetic Compatibility Test Report Test results of Floww equipment
Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww
Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success
Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN 858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe
Programmable Power Supply HM7044
12 JAN 2004 4S-7044-00E0 ENGLISH SERVICE-MANUAL Instruments Programmable Power Supply HM7044 HM7044 2 Programmable Power Supply HM7042 CE - Declaration of conformity... 4 General information regarding
Inductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified
804 Ti Stand. Manual 8.804.8001EN
804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
SanDisk Connect Wireless Flash Drive QUICK START GUIDE
SanDisk Connect Wireless Flash Drive QUICK START GUIDE GET STARTED 1. Charge your Wireless Drive Plug the Drive into a computer or USB-AC adaptor. A full charge can take up to 2 hours. 2) Turn on the
DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001
NO. HU-DOP_TN-212-25_001 Product type 212 (TN) 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-35_001 Product type 212 (TN) 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-45_001 Product type 212 (TN)
WIRELESS MAGNETIC CONTACT
WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
APPENDIX / ANHANG / ANNEXE
APPENDIX / ANHANG / ANNEXE ALPHA ALTERNATOR DIMENSIONS, INSTALLATION DRAWINGS AND CHARACTERISTICS MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006
USB/RS485 converter cable, complete
USB/RS485 converter cable, complete Instructions for use Contents Deutsch 1 Intended use 3 2 Safety 3 2.1 Safety information... 3 2.2 General information... 3 3 Description 5 3.1 Overview... 5 3.2 Connection
DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001
NO. HU-DOP_TD-25_001 Product type TD 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-35_001 Product type TD 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-45_001 Product type TD 3,5x45 mm EN 14566:2008+A1:2009
Safety information. MSX-Box. ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany
DIN EN ISO9001:2008 certified ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany Phone: +49 7229 1847 0 Fax: +49 7229 1847 222 E-mail: [email protected] Safety information
LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium
LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE Velleman Legen Heirweg 33 9890 Gavere Belgium SPECIFICATIONS DIGITAL MULTIMETER 3 1/2 backlit LCD Automatic polarity indication DC voltage 200mV to 600V in 5 steps
2013 / ZCI-2795331-DOC-00 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany. OSRAM LED module DC24B-XXXX. IEI See attached list
OSRAM Q Document number: Manufacturer or representative: Address: Brand name or trade mark: Product type: Product designation: / ZCI-2795331-DOC-00 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany
SMART LENS Camera. User Manual
SMART LENS Camera User Manual About this Manual Thank you for purchasing the KODAK PIXPRO SMART LENS Camera. Please carefully read this manual and keep it for future reference. JK Imaging Ltd. reserves
Wireless Keyboard and Optical Mouse Bundle
Wireless Keyboard and Optical Mouse Bundle Enjoy the freedom of wireless optical precision User Manual F8E832-BNDL TABLE OF CONTENTS Introduction....................................1 Compatible Equipment............................2
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
Operating Instructions
Beuler Höhe 11, D-45525 Hattingen Tel. +49(0)2324/55515 [email protected] www.stephandahlmann.com Operating Instructions Contents Page 1. Designation and Illustration of the Machine 1 2. EC Declaration
INTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
LeI E. Henri CERVELLO
AVENANT D'ArrESTATION D'EXAMEN CE DE TYPE LeI E SUPPLEMENTARY EC TYPE EXAMINATION CERTIFICATE 2 Appareil ou systeme de protection destine aetre utilise 2 Equipment or protective system intended for use
Threaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
Analog IP Gateway GXW40xx Quick Installation Guide
Analog IP Gateway GXW40xx Quick Installation Guide Part Number: 418-02007-10 Document Version Number: 1.0 GXW 4004/8 GXW 4024 1 Grandstream Analog IP Gateway GXW40xx Quick Installation Guide WARNING: Please
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities
Linear Heat Series Fiber Optic Linear Heat Detection System Tunnels & Metros Conveyer Belts Parking Lots Manufacturing Warehouse Facilities Refineries and Power Plants Intelligent Solutions Are you looking
2015 / 9C1-3135351 -DOC-01 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany. Lamp controlgear HTi DALI 105/230-240.
OSRAM Document number: Manufacturer or representative: Address: Brand name or trade mark: Product type: Product designation: 2015 / 9C1-3135351 -DOC-01 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany
ATEX GUIDELINES (FIRST EDITION)
-1- ATEX GUIDELINES (FIRST EDITION) GUIDELINES ON THE APPLICATION OF COUNCIL DIRECTIVE 94/9/EC OF 23 MARCH 1994 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING EQUIPMENT AND PROTECTIVE
How To Save Money On Compressed Air
Guide for ultrasonic leak detection in compressed air systems in an industrial environment Copyright 2014 by SDT International n.v. s.a. Second edition, English version. All rights reserved. Reproduction
Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide
Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608 Installation Guide Introduction The NETGEAR 5/8-Port Gigabit Ethernet Switch Model GS605 / GS608 provides you with a high-speed, reliable, easy-to-use
AVENANT D'ArrESTATION D'EXAMEN CE DE TYPE Lei 2 Appareil ou systeme de protection destine aetre utilise 2 en atmospheres explosibles (Directive 94/9/CE) 3 Numero de I'avenant : 3 LCIE 99 ATEX 6006 X 104
HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic
HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic Heol fleet tracking system GPS N103 -OBD GPRS FTS Software Internet Main office - Control room Other office The specifications in this document
Specification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
An Introduction to ATEX -
An Introduction to ATEX - Meeting the Challenges of European Directive 94/9/EC (ATEX 95) Presented by Andy Holmes ATEX Consultant, TÜV Product Service Ltd 1. Introduction 1.1 Objectives of explosion protection
ÖNORM EN 1504-8. The European Standard EN 1504-8 has the status of an Austrian Standard. Edition: 2005-02-01. Standards group B
ÖNORM EN 1504-8 Edition: 2005-02-01 Standards group B Identical (IDT) with EN 1504-8:2004 ICS 91.080.40 Products and systems for the protection and repair of concrete structures Definitions, requirements,
CE Marking and Technical Standardisation
GAMBICA Technical Guide CE Marking and Technical Standardisation Guidelines for application to Electrical Power Drive Systems Edition 4 : 2015 CE Marking and Technical Standardisation Guidelines for application
Attachment to GB/FME/ExTR08.006/05 Electrical Apparatus FEP3** ProcessMaster Electromagnetic Flowmeter FEP5** ProcessMaster Electromagnetic Flowmeter FEH3** HygienicMaster Electromagnetic Flowmeter FEH5**
ETSI EN 301 489-17 V2.1.1 (2009-05) Harmonized European Standard (Telecommunications series)
EN 301 489-17 V2.1.1 (2009-05) Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Instructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
ATA User Manual. iinet ATA Telephone Adapter. Setting up for ADSL and VoIP. For model F1PG200ENau
ATA User Manual Please insert your installation CD now and then follow the on screen instructions iinet ATA Telephone Adapter Setting up for ADSL and VoIP. For model F1PG200ENau F1PG200ENau Table of Contents
EzFlex Combustible Gas Leak Detector Model EZ40
User's Guide EzFlex Combustible Gas Leak Detector Model EZ40 Introduction Congratulations on your purchase of the Extech EZ40 Combustible Gas Leak Detector. The EZ40 detects the presence of combustible
Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13
Interfacing electrification and system reliability Roger White Professional Head of Electrification and Plant Rail Abstract Integration is the term given to ensuring that the different elements of an electrified
Foxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
EC Declaration of Conformity March 15, 2012. Series 100 and 200 High Performance Current & Voltage Pressure Transducers
Series 100 and 200 High Performance Current & Voltage Pressure Transducers 97/23/EC (PED) (1) 2004/108/EC (EMC) (2) devices have been tested according to the standards: EN 61326-1:2006 EN 61326-2-3:2006