January 16-17, 2013 Santa Clara
|
|
- Adam Boone
- 8 years ago
- Views:
Transcription
1 January 16-17, 2013 Santa Clara
2 Open Rack Workshop Day 1 Matt Corddry, Facebook Pierluigi Sarti, Facebook Steve Mills, Facebook Richard Chan, Delta Products Patrick MacDonald, Sanmina Corp Eric Wilcox, Emerson Network Power
3 Introductions Matt Corddry, Open Rack Project Chair Manager, Gloria Lau Manager, Pierluigi Test Lead, Rack & Power, Facebook Mills Mech Samir Rack & Power Team, Facebook Sarti Technical Steve Facebook Hardware Design Engineer, Rack & Power, Facebook Kala Engineer, Rack & Power, Facebook
4 Introductions Richard Chan Data Center Solution R&D Manager, Delta Products Patrick MacDonald SVP, Mechanical System Division, Sanmina Corp Eric Wilcox VP of Engineering and Operations, Emerson Network Power
5 How did we get here? Open Compute Rack Overview Matt Corddry, Facebook Pierluigi Sarti, Facebook
6 19 Racks: Complex Deployment
7 19 Racks: Some Assembly Required
8 19 Racks: Loose Standards
9 Open Compute Rack v1: The Triplet Ø Great for Compute Servers
10 Open Compute Rack v1: The Triplet Ø Great for Compute Servers Ø Fixed at 1.5U Increments
11 Open Compute Rack v1: The Triplet Ø Great for Compute Servers Ø Fixed at 1.5U Increments Ø Custom PSU in every Server
12 Open Compute Rack v1: The Triplet Ø Great for Compute Servers Ø Fixed at 1.5U Increments Ø Custom PSU in every Server Ø Tool-free Server Installation
13 Open Compute Rack v1: The Triplet Ø Great for Compute Servers Ø Fixed at 1.5U Increments Ø Custom PSU in every Server Ø Tool-free Server Installation Ø Limited Flexibility
14 Colocation Rack Open Compute Rack v1 in Colocation Sites Matt Corddry, Facebook Steve Mills, Facebook
15 Colocation Rack Why? Some facilities cannot accept our Triplet racks Ø 95 Tall, 66 Wide, 2600 lbs, 480v power
16 Colocation Rack Why? Some facilities cannot accept our Triplet racks Ø 95 Tall, 66 Wide, 2600 lbs, 480v power We needed a standard rack form factor for our OCP servers
17 Colocation Rack What? A modified DAMAC 19 server rack
18 Colocation Rack What? A modified DAMAC 19 server rack Shelves and side panels from an OCP triplet rack
19 Colocation Rack What? A modified DAMAC 19 server rack Shelves and side panels from an OCP triplet rack Off-the-shelf power strips from Server Technology for 208v power
20 Colocation Rack What? A modified DAMAC 19 server rack Shelves and side panels from an OCP triplet rack Off-the-shelf power strips from Server Technology for 208v power New power cords connecting the OCP power supply to the new power strips
21 Colocation Rack When? Deployed in Facebook datacenters today
22 Colocation Rack When? Deployed in Facebook datacenters today Will be replaced with Open Rack this year Ø Open Rack works in all facilities
23 Colocation Rack Q&A (please state name & company)
24 Open Rack Update We ve Come A Long Ways Matt Corddry, Facebook Pierluigi Sarti, Facebook Steve Mills, Facebook
25 Why Open Rack? Lower Total Cost of Ownership Disaggregation of technologies Maximize component life Infrastructure cost per node is reduced Larger volume allows more nodes per rack Flexibility allows multiple generations Rack Level Standards Modular and Serviceable components Simplified data center deployment Potential Component Lifecycle in Years: CPU 4 FANS 5 Boot Disk 5 Switches 5 Memory 6 PSU 6 Rack 10
26 Open Rack Overview Ø Well-defined Mechanical API between the server and the rack
27 Open Rack Overview Ø Well-defined Mechanical API between the server and the rack Ø Accepts any size equipment 1U 10U
28 Open Rack Overview Ø Well-defined Mechanical API between the server and the rack Ø Accepts any size equipment 1U 10U Ø Wide 21 equipment bay for maximum space efficiency
29 Open Rack Overview Ø Well-defined Mechanical API between the server and the rack Ø Accepts any size equipment 1U 10U Ø Wide 21 equipment bay for maximum space efficiency Ø Shared 12v DC power system
30 Open Rack: Dimensions AC Rack dimensions: 600mm (23.6 ) wide 1067 mm (42 ) deep 2100 mm (82.7 ) tall DC 600mm Rear View Front View 538mm
31 Open Rack: Equipment Bay Total IT equipment bay space: 538mm (21 ) chassis width x 830mm (32.7 ) max chassis depth 538mm (21 ) Front view Power Zone 13 OU Equipment Bay (10 OU)
32 Open Rack: Equipment Bay Total IT equipment bay space: 538mm (21 ) chassis width x 830mm (32.7 ) max chassis depth Rack slot height measured in 48mm OpenU (OU) 538mm (21 ) Front view Power Zone 13 OU Equipment Bay (10 OU)
33 Open Rack: Equipment Bay 538mm (21 ) Total IT equipment bay space: 538mm (21 ) chassis width x 830mm (32.7 ) max chassis depth Rack slot height measured in 48mm OpenU (OU) Server space: three equipment bay at 10 OU each; IT switch space is 2 OU Power Zone 13 OU Front view Equipment Bay (10 OU)
34 Open Rack: Equipment Bay 538mm (21 ) Total IT equipment bay space: 538mm (21 ) chassis width x 830mm (32.7 ) max chassis depth Rack slot height measured in 48mm OpenU (OU) Server space: three equipment bay at 10 OU each; IT switch space is 2 OU Adjustable chassis slot height (1 OU to 10 OU, with 0.5 OU increments) Power Zone 13 OU Front view Equipment Bay (10 OU)
35 Open Rack: Mounting Server Shelf: Movable within the rack to support gear of any height (e.g. 1.5 OU, 2 OU, etc.) at 0.5 OU step increments
36 Open Rack: Mounting Server Shelf: Movable within the rack to support gear of any height (e.g. 1.5 OU, 2 OU, etc.) at 0.5 OU step increments Tool-less mounting and removal from front rack, without pulling out chassis from next slot
37 Open Rack: Mounting Server Shelf: Movable within the rack to support gear of any height (e.g. 1.5 OU, 2 OU, etc.) at 0.5 OU step increments Tool-less mounting and removal from front rack, without pulling out chassis from next slot Supports compute chassis as small as 1 OU height
38 Open Rack: Mounting Server Shelf: Movable within the rack to support gear of any height (e.g. 1.5 OU, 2 OU, etc.) at 0.5 OU step increments Tool-less mounting and removal from front rack, without pulling out chassis from next slot Supports compute chassis as small as 1 OU height Wide range of chassis height is supported (from 1 OU and up to 10 OU)
39 Open Rack: Power Power Zones: One power zone is one equipment bay (10 OU) + one power shelf (3 OU) Front view Power Zone 13 OU Equipment Bay 10 OU
40 Open Rack: Power Power Zones: One power zone is one equipment bay (10 OU) + one power shelf (3 OU) Three power zones in the column, 13 OU high (each) Front view Power Zone 13 OU Equipment Bay 10 OU
41 Open Rack: Power Power Zones: One power zone is one equipment bay (10 OU) + one power shelf (3 OU) Three power zones in the column, 13 OU high (each) Each power zone has a max of 3 bus-bar pairs (+/-) for 12V distribution, rated 350A max (4.2KW) Power Zone 13 OU Front view Equipment Bay 10 OU
42 Open Rack: Power Power Zones: One power zone is one equipment bay (10 OU) + one power shelf (3 OU) Three power zones in the column, 13 OU high (each) Each power zone has a max of 3 bus-bar pairs (+/-) for 12V distribution, rated 350A max (4.2KW) Power shelf is a single-phase power solution (3x) Power Zone 13 OU Front view Equipment Bay 10 OU
43 Open Rack: Power Power Zones: One power zone is one equipment bay (10 OU) + one power shelf (3 OU) Three power zones in the column, 13 OU high (each) Each power zone has a max of 3 bus-bar pairs (+/-) for 12V distribution, rated 350A max (4.2KW) Power shelf is a single-phase power solution (3x) Up to 7 power supplies per shelf in N+1 configuration Power Zone 13 OU Front view Equipment Bay 10 OU
44 Open Rack 3 bus-bars Efficiency Test Setup Each Motherboard power (Load Tray) is 12V (23.3A) 15 Load Trays each Power Zone (15 x 280W) = 4200W Each bus-bar pair is loaded at 1400W Three bus-bar pairs are used, for each Power Zone TOR CABLES TOR Switches 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load Power Shelf 4.2KW 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load Power Shelf 4.2KW 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load 280W load Power Shelf 4.2KW
45 Bus-Bar pair Voltage 117A and Efficiency Worst case tot voltage drop = 44mV V V 0.03W 10 OpenU tall bus-bar pair (1400W tot) V 0.05W This setup is (x3) V 0.07W 1400W 1400W 1400W V 0.18W 1.05W 117A V 3.51W V 4.2KW Power Shelf Total power loss of the whole 12V distribution system at full load, including all CLIPs, is 6.5W Max efficiency loss is 0.5%
46 Open Rack 1 bus-bar pair Efficiency Test Setup Each Motherboard power (Load Tray) is 12V (70A) 5 Load Trays each Power Zone (5 x 840W) = 4200W The central bus-bar pair is loaded at 4200W Only the central bus-bar is used, for each Power Zone TOR CABLES TOR Switches 840W load 840W load 840W load 840W load 840W load Power Shelf 4.2KW 840W load 840W load 840W load 840W load 840W load Power Shelf 4.2KW 840W load 840W load 840W load 840W load 840W load Power Shelf 4.2KW
47 Bus-Bar pair Voltage 350A and Efficiency V V Worst case total voltage drop = 102mV 0.14W 10 OpenU tall bus-bar pair (4200W total) V 0.28W This setup is (x1) V V 1.26W 3.92W 7.70W 350A not used 4200W not used V 19.6W V 4.2KW Power Shelf Total power loss of the whole 12V distribution system, including all CLIPs, is 47.6W Max efficiency loss is 1.15%
48 Open Rack: Bus Bar Clip 12V 100A Clip Clip Assembly Installed to the IT chassis, it plugs directly to the Open Rack 12V bus-bars Installed in a Compute Chassis
49 Open Rack: Bus Bar Clip 12V 100A Clip Clip Assembly Installed to the IT chassis, it plugs directly to the Open Rack 12V bus-bars Contacts are Nickel plated, max 0.3mOhms Installed in a Compute Chassis
50 Open Rack: Bus Bar Clip 12V 100A Clip Clip Assembly Installed to the IT chassis, it plugs directly to the Open Rack 12V bus-bars Contacts are Nickel plated, max 0.3mOhms Rated 80A, 100V, up to +105C Installed in a Compute Chassis
51 Open Rack: Bus Bar Clip 12V 100A Clip Clip Assembly Installed to the IT chassis, it plugs directly to the Open Rack 12V bus-bars Contacts are Nickel plated, max 0.3mOhms Rated 80A, 100V, up to +105C Power loss < 80A when mated to a nickel plated 3mm Copper bus-bar Installed in a Compute Chassis
52 Open Rack: Bus Bar Clip 12V 100A Clip Clip Assembly Installed to the IT chassis, it plugs directly to the Open Rack 12V bus-bars Contacts are Nickel plated, max 0.3mOhms Rated 80A, 100V, up to +105C Power loss < 80A when mated to a nickel plated 3mm Copper bus-bar Floating panel for self blind mating (no extra guiding pins necessary on chassis) Installed in a Compute Chassis
53 Open Rack: Bus Bar Clip 12V 100A Clip Clip Assembly Installed to the IT chassis, it plugs directly to the Open Rack 12V bus-bars Contacts are Nickel plated, max 0.3mOhms Rated 80A, 100V, up to +105C Power loss < 80A when mated to a nickel plated 3mm Copper bus-bar Floating panel for self blind mating (no extra guiding pins necessary on chassis) Chassis maybe installed at any height in the power zone Installed in a Compute Chassis
54 Open Rack: Bus Bar Clip 12V 80A Clip Clip Assembly Installed to the IT chassis, it plugs directly to the Open Rack 12V bus-bars Contacts are Nickel plated, max 0.3mOhms Rated 80A, 100V, up to +105C Power loss < 80A when mated to a nickel plated 3mm Copper bus-bar Floating panel for self blind mating (no extra guiding pins necessary on chassis) Chassis maybe installed at any height in the power zone Released into OCP and available from Methode today Installed in a Compute Chassis
55 Blind Mating: self-guiding pins for blind-mate hot-plug OCP released CLIP assembly AWG 6 cables CM choke Floating Plate: +/- 3mm horizontally +/- 4mm vertically CLIP component (2x) installed on a floating plate
56 Open Rack: Variations Cold Storage Single Power Domain Very Low Power Density
57 Open Rack: Variations EMI Shielded Front EMI panel Front and rear panels Rack-level EMI shielding For locations with this requirement Front and rear panels attach to rack frame with 10mm bolts
58 Open Rack: Variations Seismic Zone 4 Rear Cross Bracing Racks Ganged Together
59 Open Rack Q&A (please state name & company)
60 Break Check out the Open Rack!
61 Creating a Standard Interface between Node and Rack Steve Mills Facebook Mechanical Engineer
62 What was released since last time Open Rack V1.0 Covers the technical detail to produce Open Rack
63 What was released since last OCP Design Guide 0.5 Provides detail on how to create a generic chassis that is compatible with the Open Rack design
64 Design Guide 0.5 Overview Front Side Top
65 Retention Features for Equipment 12x18 mm rectangle Spring Cam Cage latch surface nut
66 Retention Features 5mm tall lance every 48mm
67 Reference Design for Chassis DC Power clip location Chassis size Latching location
68 Creating a Standard Goal: Define the minimal amount of specification to ensure interoperability between the rack and the IT equipment to be installed. Goal: Enable the rack and IT equipment ecosystem to innovate within this well defined interface.
69 What Should be Part of the Standard? DC Power Connection Maximum depth of contact mate on the busbar Electrical properties a function of power draw Alignment Amount of float prior to mate Clip alignment method keep-out zone Cycle life Connection to PWA in the system
70 What Should be Part of the Standard? Busbar Mechanical Location in space relative to retention location Reserved Zone for clip interface Cycle Life Electrical properties Max ambient temperature
71 What Should be Part of the Standard? Equipment retention feature Shape and location of the retention Max forces the location can handle Equipment Support Bracket Width and length of supporting surface Loading rating per pair Retention Method in the rack
72 What Should be Part of the Standard? Rack interfaces to the data center Rack Width Bolt down locations for seismic applications Baying interfaces Hot-aisle containment features
73 Day One is Done! See you 9AM
74 Delta Open Rack Richard Chan
75 Sanmina Open Rack Patrick MacDonald
76 Emerson Open Rack Eric Wilcox
77 Thanks!
78 January 16-17, 2013 Santa Clara
79
Open Rack Charter. Authors: Gio Coglitore, Pierluigi Sarti, John Kenevey, Pete Bratach
Open Rack Charter Authors: Gio Coglitore, Pierluigi Sarti, John Kenevey, Pete Bratach Contents Contents... 2 Mission Statement... 3 Summary... 3 Overview... 4 License... 4 Design Approach... 5 Physical
More informationOpen Rack Hardware v1.0
Open Rack Hardware v1.0 Authors: Pierluigi Sarti, System Designer Steve Mills, Mechanical Engineer 1 Scope This document describes the technical specifications for the custom rack that houses Open Compute
More informationDeploying OCP Hardware in a Collocated Facility
Deploying OCP Hardware in a Collocated Facility Authors: Pierluigi Sarti, Technical Lead, Rack & Power, Facebook and Pete Bratach, Technical Writer, Facebook 1 Scope This specification describes how a
More informationData Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM
Data Center Rack Systems Key to Business-Critical Continuity A White Paper from the Experts in Business-Critical Continuity TM Executive Summary At one time, data center rack enclosures and related equipment
More informationCabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
More informationRack installation instructions
Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:
More informationComponent Series Racks... 1 2 Component Series Rack Plus Bundles...3 Component Series stackable skeleton Racks...4
SANUS RACKS Table of Contents Component Series Racks... 1 2 Component Series Rack Plus Bundles...3 Component Series stackable skeleton Racks...4 sanus EcoSystem... 5 6 sanus EcoSystem Bundles...7 Rack
More informationSecure your IT equipment with confidence... secure with NetClosure
Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.
More informationInstaPATCH ZERO Solution Guide
SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving
More informationRack Systems Solutions
Rack Systems Solutions Designed to simplify cable management and improve power distribution Engineered by APC by Schneider Electric for Dell, NetShelter S is the next-generation rack enclosure solution
More informationColocation Rack Secure, Separate Server Hosting and Housing in Data Centers
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required
More informationArgus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure
Summary Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure This is a general procedure on how to replace Pathfinder 48-10kW shelf with a Cordex 3.6kW shelf. Part Numbers 010-567-20
More information19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
More informationCustomized Server Cabinets
GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.
More informationDCF Optimized Rack System Selection Guide
DCF Optimized Rack System Selection Guide DCF Optimized Rack System: Optimized Design, Optimized Delivery, Optimized Value A Rack System Designed to Meet The Challenges Your Data Center Faces Today Your
More informationRittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
More informationUsing a Fabric Extender with a Cisco Nexus 5000 Series Switch
CHAPTER Using a Fabric Extender with a Cisco Nexus 5000 Series Switch This chapter describes the Cisco Nexus 000 Series Fabric Extenders (FEXs) and includes these sections: Information About, page - Cisco
More informationData Sheet Fujitsu PRIMERGY BX400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Blade Made Easy Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost way to build and run an IT infrastructure in your midsize organization,
More informationServer Chassis and Triplet Hardware v1.0
Server Chassis and Triplet Hardware v1.0 Author: Steve Furuta, Mechanical Designer 1 Scope This document describes the technical specifications for the custom chassis used in Open Compute Project servers
More informationI. Introduction 02. Specifications 02 Accessories 02 Features 03. II. Installation Instructions 06
EN I. Introduction 02 Specifications 02 Accessories 02 Features 03 II. Installation Instructions 06 1. Installation of the motherboard 06 2. Installation of the power 07 supply 3. Installation of external
More informationTyan Computer. Transport PX22. Service Engineer s Manual
Tyan Computer Transport PX22 Service Engineer s Manual 1 Precaution To read through the user manual, check all assembly and follow setup process before any operation on this server To keep paper clips,
More informationCabinet V800 V800 CABINETS
V800 Cabinet Siemon s V800 cabinets provide a robust, cost-effective enclosure solution that provides valuable Zero-U space on each side of the equipment rails for cable management, PDU mounting or connectivity
More informationDELTA3-1. Delta 3 Data Centre Rack Solution
DELTA3-1 Delta 3 Data Centre Rack Solution Contents Building on more than 50 years of British design and innovation, Cooper B-Line introduces Delta 3 ( Delta cubed ). Designed to offer M.O.R.E. to customers
More informationIT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
More informationData Sheet Fujitsu PRIMERGY BX600 S3 Blade Server
Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server Advanced Blade Ecosystem the ideal platform for branch offices and mediumsized companies Fujitsu PRIMERGY BX Blade Servers meet all the requirements of
More informationFujitsu PRIMERGY BX600 S3 Blade Server
Datasheet Fujitsu PRIMERGY BX600 S3 Blade Server Advanced Blade Ecosystem - the ideal platform for branch offices and medium-sized companies The PRIMERGY BX Blade Servers are the ideal choice for the data
More informationHow To Buy An Fujitsu Primergy Bx400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server BLADE MADE EASY - tailor-made for medium-sized companies Fujitsu PRIMERGY BX Blade Servers meet all the requirements of medium-sized companies as well
More informationHow To Build A T7 Rack For Information Technology
THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility
More informationData Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing
More informationWhat is a Datacenter?
What is a Datacenter? Telecom Room Primarily Cross Connect Equipment and switches. Computer room A room whose primary function is to house computer equipment. (Servers, Storage) 5 or less cabinets Small
More informationA QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000
A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000 A Principled Technologies setup guide commissioned by Dell Inc. TABLE OF CONTENTS Table of contents... 2 Introduction... 3 Dell 42U rack...3
More informationHigh Availability Server Hardware v0.5 MB-draco-batentaban-0.5
High Availability Server Hardware v0.5 MB-draco-batentaban-0.5 Author: Jia Ning, Hardware Engineer, Facebook 1 Scope This document describes the technical specifications used in the design of a server
More informationRacks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.
Three simple words that clearly describe how we approach a Data Center project. Eclipse Racks & Enclosures DELIVERING THE RIGHT INFRASTRUCTURE FOR YOUR MISSION-CRITICAL NEEDS SERVER RACKS & NETWORKING
More informationHow to Set Up Your NSM4000 Appliance
How to Set Up Your NSM4000 Appliance Juniper Networks NSM4000 is an appliance version of Network and Security Manager (NSM), a software application that centralizes control and management of your Juniper
More informationData Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Scale-Out Smart for HPC and Cloud Computing with enhanced energy efficiency The PRIMERGY CX400 Cloud extension servers are Fujitsu
More information7.1 id Intelligent Infrastructure Management. 7.2 id Active
7 HellermannTyton has a range of hardware products for use with Intelligent Infrastructure Management software. Page Page 7.1 Intelligent Infrastructure Management Category 6 Patch Leads 194 Category 5e
More informationInstallation. Basic Rack Power Distribution Unit for Blade Servers
Installation Basic Rack Power Distribution Unit for Blade Servers Contents Preliminary Information...................1 Features............................. 1 Receiving inspection................... 1
More informationExpress5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
More informationDealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges
More informationINSTRUCTIONS: LocknCharge Laptop Carts
INSTRUCTIONS: LocknCharge Laptop Carts www.lockncharge.com Extra Tools required: Hammer, Philips head screwdriver, medium adjustable spanner. (Allen key supplied) (Panel colours for illustration purposes
More informationTorpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3
Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3 Author: Conor Malone, VP Engineering, Hyve Solutions 1 Scope This document discusses the requirements and specifications
More informationData Sheet Fujitsu PRIMERGY BX900 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server The Dynamic Cube Fujitsu PRIMERGY BX Blade Servers meet all the requirements of medium-sized companies as well as the branches and data centers of large
More informationRaritan LCD KVM Console (T1700/T1900)
QS Rule Raritan LCD KVM Console (T1700/T1900) Quick Setup Guide Thank you for your purchase of the LCD KVM Console, one of the best-known LCD KVM drawers in the current market. The Raritan LCD KVM Console
More informationPGS Introduction. "Value Series" : Best VALUE gaming cases with the highest C/P Ratio (Cost to Performance ratio).
"Value Series" Best VALUE gaming cases with the highest C/P Ratio (Cost to Performance ratio). "Professional Series Red label" Super tower or Super mid-tower cases with elegant, clean line designs. PGS
More informationWHITEPAPER THE FUTURE IS CUSTOM: A TOTAL COST OF OWNERSHIP APPROACH TO DATA CENTER INFRASTRUCTURE DESIGN
WHITEPAPER THE FUTURE IS CUSTOM: A TOTAL COST OF OWNERSHIP APPROACH TO DATA CENTER INFRASTRUCTURE DESIGN EXECUTIVE SUMMARY Although racks and cabinets are among the least expensive components of the IT
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationMotherboard- based Servers versus ATCA- based Servers
Motherboard- based Servers versus ATCA- based Servers Summary: A comparison of costs, features and applicability for telecom application hosting After many years of struggling for market acceptance, it
More informationData Sheet Fujitsu PRIMERGY BX400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Blade Made Easy Fujitsu PRIMERGY BX Blade Servers meet all the requirements of medium-sized companies as well as the branches and data centers of large
More informationData Sheet FUJITSU PRIMECENTER M2 19-inch Racks
Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks 19-inch Industry Standard Rack Systems The trend to consolidation as a result of virtualization and optimization
More informationADC-APC Integrated Cisco Data Center Solutions
Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide ADC-APC Integrated Cisco Data Center Solutions The evolution of data centers is happening before our eyes. This is due to the
More informationHow To Build A Cisco Uniden Computing System
Data Sheet Cisco UCS 5100 Series Blade Server Chassis Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites computing,
More informationATX Mid Tower PC Case. MS800 Series. Ver. 121214
ATX Mid Tower PC Case MS800 Series MS800 MS800 Plus Ver. 121214 ENGLISH 1 Cautionary Notes 1) Please read this manual thoroughly prior to installation. 2) Before installing, check the components and condition
More informationVantage Enclosure Systems
Vantage Enclosure Systems Custom-configured solutions to store your mission-critical hardware IT Co-location Managed Server Facility WEB HOSTING communications ISP E-business Vantage Enclosures Vantage
More informationRack Installation Instructions
Rack Installation Instructions Guidelines This publication provides information about how to install your server into a standard rack cabinet using the rail kit shipped with your server. If you no longer
More informationDirectory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
More informationDD670, DD860, and DD890 Hardware Overview
DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.
More informationRaritan LCD KVM Console (T1700/T1900)
Raritan LCD KVM Console (T1700/T1900) Quick Installation and Setup Guide Congratulations on your purchase of Raritan LCD KVM Console, one of the best-known LCD KVM drawers in the current market. The Raritan
More informationQuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview
Overview Fixed Cord PDUs and Extension Bars have a unique architecture designed specifically for 1U fixed rail servers (HP ProLiant DL360, HP ProLiant DL320, HP ProLiant DL140). This new design consists
More informationImproving Rack Cooling Performance Using Airflow Management Blanking Panels
Improving Rack Cooling Performance Using Airflow Management Blanking Panels By Neil Rasmussen White Paper #44 Revision 3 Executive Summary Unused vertical space in open frame racks and rack enclosures
More informationIntroducing an innovative team devoted to providing unparalleled customer service and support for ISPs, ASPs and Hosting applications.
Introducing an innovative team devoted to providing unparalleled customer service and support for ISPs, ASPs and Hosting applications. The partner you can rely on - APW's Internet Business Solutions Team
More informationEnergy-efficient & scalable data center infrastructure design
Seminar am 30. September 2010 in Wetzlar Nachhaltigkeit durch UPI (Unified Physical Infrastructure) Vortrag von Stefan Fammler: Energieeffiziente Strategien im Rechenzentrum Energy-efficient & scalable
More informationPower Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation
One Dell Way Round Rock, Texas 78682 www.dell.com Dell Enterprise White Paper Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation January, 2008
More informationFiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications
Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Topics! Understanding Fiber Types! Powering your Remotes via Composite Fiber! Fiber Design
More informationBLADE S-MAX Cabinet for Blade Server
Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and
More informationKnürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
More informationHow To Test A Power Distribution Unit
PDUAC3U SERIES AC POWER DISTRIBUTIO UITS www.unipowerco.com Manual o. PDUAC3U-1 pduac3u-man-rev1-1015.indd 2015 UIPOWER LLC All Rights Reserved ORTH AMERICA 3900 Coral Ridge Drive, Coral Springs, Florida
More informationCompaq Rack Options and Accessories. Monitors and Keyboards
1 Compaq Rack Options and Accessories Compaq offers a wide variety of rack options and accessories that help you to complete your 9000 and 10000 series racks. Monitors and Keyboards TFT5600RKM United States
More informationNEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures
NEW RANGE OF CABINETS DRIVIATM Innovation at your service THE GLOBAL SPECIALIST in electrical and digital building infrastructures Drivia true innovation The new electrical panel for the residential and
More informationinstallation guide ACTIV-1
installation guide ACTIV- Base foot. Leg x columns - right & left Motor unit. Work surface supporting bracket (Cantilever) x Control. box Base foot x Handset 4. Phase Motor unit Materials and Tools Hardware
More informationDCF Optimized Rack System
Integrated Cabinet Solutions For Business-Critical Continuity DCF Optimized Rack System User Manual IMPORTANT SAFETY GUIDELINES SAVE THESE INSTRUCTIONS This manual contains important instructions that
More information42U/45U 28" Wide Rack Installation & Service Guide
42U/45U 28" Wide Rack Installation & Service Guide 96-00171-005 Rev B Important Information Information in this document is subject to change without notice and does not represent a commitment on the part
More informationHP Cloudline Overview
HP Cloudline Overview Infrastructure for Cloud Service Providers Dave Peterson Hewlett-Packard Company Copyright 2015 2012 Hewlett-Packard Development Company, L.P. The information contained herein is
More informationSpec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.6 DECEMBER 9, 2014 WWW.CISCO.
Spec Sheet CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.6 DECEMBER 9, 2014 WWW.CISCO.COM Overview................................................ 3 Rack Certifications
More informationST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
More informationDimensions (HxDxW) Total Cabinet Area 89.96x 39.69 x 24 in/ 2,285 x 1,008.17 x 612.77 mm 95.47x 48 x 32 in/ 2,425 x 1,219.2 x 812.
1 Compaq 10000 Series Racks The 10000 series racks are a family of 1000mm deep racks which are available in 22U, 36U, 42U and 47U 600mm widths. Compaq 10000 Series Racks provides a common, integrated platform
More informationINSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
More informationHP ProLiant DL380 G6 Carrier-Grade Server Read Before Install
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,
More informationHP ProLiant DL165 G7 Server. Installation Instructions
HP ProLiant DL165 G7 Server Installation Instructions Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 HDD Item 1 Thumbscrews for rack mounting 2 Drive status
More informationLinkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
More informationDistributing Power to Blade Servers
Distributing Power to Blade Servers Ten steps to selecting the optimal power distribution design With the growth in blade servers with dual or triple power supplies, a single rack of equipment can easily
More informationAmphenolR. Now you're connected!
Table of Contents CoolPower Overview... Page 3 CoolPower Slim Drawer - DW Series... Page 4 CoolPower D-Sub - LCC17 Series... Page 7 Amphenol Power Solutions... Page 9 Other Amphenol Commercial Products...
More informationAC SERIES DUAL 1/4 (6.35mm) / XLR
AC SERIES DUAL 1/4 (6.35mm) / XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 ) phone jack
More informationHP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
More informationCisco Nexus 7000 Series.
Data Sheet Cisco Nexus 7000 Series Chassis Product Overview The Cisco Nexus 7000 Series Switches combine the highest levels of scalability with operational flexibility. The Cisco Nexus 7000 Series Switches
More informationIntel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel
More informationRelay mounting systems
Page 1 Issued July 1998 Changed since April 1997 Data subject to change without notice RL COMBIFLEX RE 500 (SE 94832) (SE 970140) (SE 950216) Features Suitable for standard 19 rack, flush, semiflush, projection
More informationPowerware Enclosure Solutions Product Focus
Powerware Enclosure Solutions Product Focus Powerware Enclosures IT availability and reliability are critical corporate issues in today s demanding, mission-critical environments. For this reason, it is
More informationHP Laser Jet 4200/4240/4250/4300/4350 Swing Plate
HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate 1 Swing Plate Assembly-RM1-0043 1 Swing Plate Kit-5851-2766 (RM1-0043 plus RM1-1091 gear) CAUTION: Fuser may be hot. Turn off printer, unplug it and allow
More informationSMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits
INTRODUCTION The Radiall Type 43 coaxial connector range The Radiall range of Type 43 series connectors is fully approved (where applicable) to BT (British Telecom) standards as well as to British Standard
More informationSMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays
SMARTPLAY7 Increase your Deal Size and Profitability with SmartPlays - Comstor and Panduit have joined forces to promote the power and flexibility of UCS combined with market leading energy efficient enclosures.
More informationFigure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4
This specification covers the requirements for application of ELCON Drawer Series Connectors: True Hot Plug, Blind Mating Mixed Signal and Power Connectors. These connectors are designed for use in pluggable
More informationData Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise
More informationVoltech DC1000. Precision DC Bias Current Source
DC1000 Precision DC Bias Current Source DC1000 Precision DC Bias Current Source TM Integral Rack Mount Lugs High Contrast Green LED Display Easy Control Rotary Knob Output LED Indicator DC 1000 OUTPUT
More informationElma Bustronic VPX Test Extender User Manual
Elma Bustronic VPX Test Extender User Manual Elma Bustronic used creative engineering to solve a major problem in developing the VPX Extender Board - the lack of a right angle receptacle for VPX in the
More informationRACK ENCLOSURES & ACCESSORIES
RACK ENCLOSURES & ACCESSORIES RACK ENCLOSURES NetshelterTM 1 NetShelter VX / NetShelter VS 2 Open Frame Racks 3 NetShelter ES 4 NetShelter WX Part Number Model Height Width Depth Color Application Doors
More informationCG2100 Carrier Grade Server. Document Revision 1.2
CG2100 Carrier Grade Server Document Revision 1.2 September 2014 Revision History Revision Date Comments 1.0 April 29, 2010 Initial revision for production. 1.1 March 30, 2011 1.2 September 17, 2014 Added
More informationUnified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers
Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers Deploying a Vertical Exhaust System www.panduit.com WP-09 September 2009 Introduction Business management applications and rich
More informationInstaPATCH Cu Cabling Solutions for Data Centers
SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 Instapatch Cu Solution Specification 2 Harness Assembly Design 3
More informationAC SERIES-C TYPE DUAL CONNECTORS JACK/XLR
AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 )
More informationUCS M-Series Modular Servers
UCS M-Series Modular Servers The Next Wave of UCS Innovation Marian Klas Cisco Systems June 2015 Cisco UCS - Powering Applications at Every Scale Edge-Scale Computing Cloud-Scale Computing Seamlessly Extend
More information