1 Commercial, Industrial and Residential Fire Systems

2 BROOKS is an Australian family owned business specialising in producing high quality fire systems. Along with sophisticated Panasonic Technology and highly qualified engineering and manufacturing staff, BROOKS take pride in producing the products in this catalogue. Product Guide Index Fire Panels BROOKS Intelligent Analogue Addressable C.I.E Page 1 Fire Panels Analogue Addressable C.I.E - Options Page 3 Analogue Addressable Detectors Page 5 Analogue Addressable Detectors and Devices Page 7 Fire Panels Conventional Page 13 Conventional Detectors and Devices Page 14 Fire Panels Residential Fire Systems Page 17 Fire Panels Local Control Panels Page 20 Specialised Panels and Devices Page 21 Specialised Panels Devices Page 22 Occupant Warning Systems Page 24 Accessories Page 26 Accessories Sight and Sound Products and Intrinsically Page 27 Safe Detectors Fire Industry Acronyms Page 28 Fire Terms Glossary Page 29 Notes Page 31 E & OE. Information subject to change without notice including terms and conditions of sale.

3 BROOKS FT1020G3 Analogue Addressable C.I.E. The Next Generation of Intelligent Analogue Addressable Control and Indicating Equipment (C.I.E) FT1020G3 Intelligent Analogue Addressable C.I.E Firetracker FT1020G3 is an intelligent analogue addressable fire system, conforming to the AS Control and Indicating Equipment, AS Power Supply and AS Fire Brigade Panel standards. FT1020G3 is the third generation of BROOKS intelligent analogue addressable systems. It meets the most stringent requirements in order to secure real fire alarms and to reduce nuisance alarms. Dimensions: Large cabinet: 920mmH x 450mmW x 220mmD (including door) Standard cabinet: 630mmH x 450mmW x 220mmD (including door) Up to 1020 addresses per control and indicating equipment (C.I.E) Redundant network for up to 30 control units with two TLON networks Large front display makes FT1020G3 user-friendly An optional panel mount printer can be added if required A user friendly PC software EBLWin is used to create, edit, download (back up) the site specific data (SSD). It is also used for the maintenance, new SW downloads, etc Adaptation of each analogue detector s alarm level in relation to its contamination. A service signal will be given when a detector has to be replaced Advanced Alarm Algorithms for contamination compensation, self diagnostics and filtering the nuisance alarms from the real fire alarms and one algorithm is used for faster detection of smoldering fires User related functions eg; Test mode, time channels, alarm delay, Alert Annunciation, disablements of outputs and inputs, two-unit dependence, user definable alarm text for each alarm point etc Programmable inputs and outputs on the COM loop. A larger number of trigger conditions are available Expansion boards (options) up to six boards with conventional zone line inputs, relay outputs and/or supervised inputs and outputs Interface for External Presentation units, Alert Annunciation Units, etc Web-server 1598 (option) can connect the system to Internet (LAN), for status presentation and remote control via a PC (web browser) I/O matrix boards for 1668 fan control, zone disable, remote mimic applications, etc 5058 FT1020G3 Printer Page1 Page 1

4 BROOKS Intelligent Analogue Addressable Control and Indicating Equipment (C.I.E) FT128V2 Single Loop Analogue Addressable C.I.E The BROOKS firetracker FT128V2 is a single loop intelligent addressable C.I.E configured to accommodate with up to 255 analogue addressable detectors or devices on a single loop Note: The FT128 has had an upgrade to FT128V2 to increase loop capacity FT512 4 Loop BROOKS Analogue Addressable C.I.E The BROOKS firetracker FT512 has been superseded by the FT1020G3 third generation C.I.E FT128V2/FT512 Standard Enclosure 630mmH x 450mmW x 220mmD FT128V2/FT512 Large Enclosure 920mmH x 450mmW x 220mmD User programmable inputs and outputs in the C.I.E and/or via I/O units on the COM loop Service signal is given when a detector is contaminated to a certain level A large number of fire detection algorithms are supported by the system and can be set individually for each analogue detector Intelligent alarm algorithms and a unique self learning algorithm to detect smoldering fires Self diagnostics function detects every deviation from the accurate normal condition in the electronics and in the detection chamber A large variety of units can be connected to the COM loop: o Analogue addressable smoke and heat detectors o Intrinsically safe analogue addressable smoke and heat detectors o Waterproof heat detectors o Addressable manual call points, waterproof version is also available o Addressable short circuit isolators o Addressable sirens/sounder bases o Addressable Red Strobe (Beacon) o Light module o Addressable I/O units, and voltage output units o Addressable power supplies o Conventional detectors via I/O units Display of actual system status on a PC or pocket PC via an optional web server connected to an intranet (LAN) or the internet Up to 30 firetracker FT512 C.I.E s can be connected to a TLON network note this facility is NOT available with the FT128 Page2 Page 2

5 Fire Panels Analogue Addressable C.I.E - Options A full range of optional equipment to enhance and add to the performance of the firetracker series of Analogue Addressable C.I.E s has been designed and manufactured in Australia by BROOKS. The main options are listed below but other options to meet specific requirements are available on request: Isolate OCCUPANT WARNING SYSTEM Auto Fault PA Mic Alert Man Evac Press PA To Talk Occupant Warning Systems (OWS) The BROOKS integrated Occupant Warning System provides reliable audible and visual warnings to building occupants via speakers and strobes. The standard amplifier sizes available are 60 watt and 120watt but 20 watt and 250watt are available to special order. The OWS system comprises a main control board, a main display board, audio amplifier, optional 4 zone expansion board, optional PA 8 zone display board. Select Select Select Select PA ZONE SELECTION Select Select Select Select Disable Disable Disable AL DS FT AL DS FT AL DS FT ZONE CONTROL AL Disable DS Disable FT AL Disable DS Disable FT AL Disable DS Disable FT AL DS FT AL DS FT AL DS FT Disable Disable Disable LED Test AL DS FT AL DS FT AL DS FT Zone Control Each module provides alarm indication, fault indication and disable control for up to 12 zones configured in Win128, EBLWin or Win512. Up to 2 modules (24 zones) can be fitted in FT128 control panel (considering other options) up to 4 modules (48 zones) in FT512 and up to 6 modules in FT1020G3. The zone control module is normally mounted in the CIE but it is also possible to connect the module externally via the COM loop and external 24V DC supply. The module provides a simplified indication for zone status without the need for a crystal display. The disable button allows a specific zone to be temporarily disabled without the need to access the CIE menu. This typically used where building works or maintenance procedures are being carried out in a localized area of a building. F Running A Stopped N Fault On Auto Off Fan Reset F Running F Running A Stopped A Stopped N Fault N Fault On On Auto Auto Off Off 1668 FAN CONTROL F Running A Stopped N Fault On Auto Off LED Test AS1668 Fan Controls The fan control module is designed to meet the requirements of the Australian standard AS The module consists of a universal I/O matrix board 4582 and AS1668 fan control application board SUB902. It can be configured in Win128 EBLWin and Win512. The fan control application board provides controls and fan status indications for 4 of any fan type. Up to 8 fan modules (32 fans) can be fitted in FT128 control unit, up to 16 fan modules (64 fans) in FT512 and up to 24 fan modules (96 fan) in FT1020G3. Note: the total number of fan modules shall be reduced if other options are fitted, e.g. zone control module, generic mimic module, etc. Page3 Page 3

6 Fire Panels Analogue Addressable C.I.E Options 1598 Webserver The Panasonic 1598 Webserver is mounted within the FT128, FT1020G3 or FT512 C.I.E. A cable and accessories kit is supplied with the Webserver. The Webserver allows the user to view the actual status of the FT128, FT1020G3 or FT512 in PC via internet or intranet (LAN). s can be sent in case of fire alarm, prewarning, test mode alarm, fault, disablement and/or service signal Fire Alarm Systems TLON Manager Kit The TLON Manager kit 5095 is intended for the fire alarm systems FT512 and FT1020G3 when two or more c.i.e s shall be connected in a TLON network. The kit contains the following: U10 USB Network interface type 75010R Network connection cable (1.5 m) USB memory stick, containing: Echelon LNS Server,etc The PC program TLON Manager 2.0 Documentation (Operating Instr.) USB extension cable (0.6m) License (for 64 credits per PC) U10 USB Network interface type 75010R TLON Manager 2.0 is the PC software with which a TLON project is created and installed into the network units. It is also used for maintenance of the TLON Network. USB Memory stick and USB extension cable (0.6 m) Network connection cable (1.5 m) BA-LASIF Interface Card The BROOKS LAS Interface Card has been primarily designed to interface the BROOKS FT firetracker C.I.E s to most commonly used Nurse Call systems. Page4 Page 4

7 Analogue Addressable Detectors The BROOKS range of Analogue Addressable Detectors and some Devices are manufactured by Panasonic and are available exclusively in Australia and New Zealand through your nearest BROOKS outlet. For use with the BROOKS FT128, FT512 and FT1020G3 series of Analogue Addressable C.I.E BROOKS Multi Sensor Photoelectric (Optical) and Thermal The multi detector contains one photo-electric (optical) smoke detector and one heat detector within the low profile housing The latest IC technology will secure the highest reliability possible It has unleaded soldering The smoke detection chamber has a high-efficient optical system with an infrared light LED and a photodiode with two lenses Light reflection is used to detect smoke, which enters the detection chamber through an insect filter and an optical labyrinth The heat sensing element is a thermistor The detector is supplied with two red LEDs that will be blinking when the detector has activated alarm It also has a green polling LED. The detector is plugged in an analogue base (3312 / 4313 / 3379) The COM loop is connected to the base, which also can have terminals for an external LED, e.g. BARIL The detector is intended for indoor use in dry premises and in the firetracker systems FT128 / FT512 / FT1020G3 The detector is prepared for an advanced mode to be used in conjunction with future version of firetracker SW versions as well as current software versions Complies with AS and AS (Replaced July 2013 by 4400) BROOKS Multi Sensor Photoelectric (Optical) and Thermal Multi detector is a photoelectric (optical) smoke detector and a heat detector within one low profile housing Set via Win 128 or Win 512 software to operate as: Two separate detectors, smoke as one zone and heat as another zone One detector, either smoke detector or heat detector activates fire alarm Page5 Page 5

8 Analogue Addressable Detectors 4401 BROOKS Analogue Photoelectric (Optical) Smoke Sensor The photoelectric (optical) smoke detector has a low profile housing The latest IC technology will secure the highest reliability possible. It has unleaded soldering The smoke detection chamber has a high-efficient optical system with an infrared light LED and a photodiode with two lenses Light reflection is used to detect smoke, which enters the detection chamber through an insect filter and an optical labyrinth The detector is supplied with two red LEDs that will be blinking when the detector has activated alarm. It also has a green polling LED The detector is plugged in an analogue base (3312 / 4313 / 3379) The COM loop is connected to the base, which also can have terminals for an external LED, e.g. BARIL The detector is intended for indoor use in dry premises and in the firetracker systems FT128 / FT512 / FT1020G3 Complies with AS (Replaced July 2013 by 4401) BROOKS Analogue Photoelectric (Optical) Smoke Sensor The photoelectric (optical) smoke detector has a low profile design Page6 Page 6

9 Analogue Addressable Detectors and Devices 3308 BROOKS Analogue Heat Sensor Three different algorithms Class A1: 54-65⁰C. Class A2S: 64-70⁰C and Class BS: 69 85⁰C Complies with AS BROOKS Enclosed Analogue Heat Sensor (IP67) Three different algorithms Class A1: 54-65⁰C. Class A2S: 64-70⁰C and Class BS: 69 85⁰C ATEX compliance Waterproof (IP67) Complies with AS Address Setting Tool Used for COM loop address and mode settings Dimensions: 220mm x 145mm x 20mm 1736 Alert Annunciation Unit Control and indicating unit for alert annunciation Compact size Acknowledge button Stores up to 617 programmable text messages Built-in buzzer with silence button Page7 Page 7

10 Analogue Addressable Detectors and Devices Dimensions: 220mm x 145mm x 20mm 1728AU External Presentation Unit For presentation of pre-warning, fire alarms, common faults and common disablements Compact size Stores up to 617 programmable text messages Built-in buzzer with silence button 3366AU BROOKS Loop Monitored 4 Amp External Power Supply Monitored from the C.I.E via the COM loop 230 VAC input, 24 VDC output at 4 AMP Space for 2 sealed lead acid batteries inside the housing up to 12 AH 3312 BROOKS Analogue Base Common base for the different analogue detectors The base has screw terminals for the COM loop (in/out) Output for external LED indication (RIL) A label holder could be mounted in the base (in the label holder recess) Used in the systems firetracker FT512, firetracker FT128 and firetracker FT1020G3 systems The base is intended for indoor use and in dry premises Label holder recess on label is required Page8 Page 8

11 Analogue Addressable Detectors and Devices o 3379 BROOKS T3 Addressable Sounder Base Programmable sounder in the firetracker FT512, firetracker FT128 and firetracker FT1020G3 systems Three different sound types and priority levels Powered of the COMS loop Sound types The frequency is 3650 ± 350 Hz for all three Sound types. 1. Steady (continuous), default for priority level Hz (167 ms on / 167 ms off), default for priority level Hz (500 ms on / 500 ms off), default for priority level 3 Analogue detector plug directly into the base High sound output option in FT1020G3V2.0.x and FT128V2.0.x Max 50 per COM loop o 4380 BROOKS Addressable Beacon Swallow or deep base Low current consumption thanks to LED Technology Connected directly on the COM loop 4313 BROOKS Short Circuit Isolator Base 4313 is an analogue base with built-in Short circuit isolator Surface mounted and is suitable for use with any BROOKS analogue detector The 4313 can be used in conjunction with the short circuit isolator unit 4370 Used in the firetracker FT512, firetracker FT128 and firetracker FT1020G3 systems to increase the COM loop safety Up to 64 isolators (4313 / 4370) can be connected on each COM loop for FT1020G3V2.0.x and FT128V.2.0.x Isolates a short circuit on a COM loop Specific fault messages to locate the short circuit across the COM loop Requires COM loop address Page9 Page 9

12 Analogue Addressable Detectors and Devices 3333 BROOKS Addressable Manual Call Point Built-in LED indicator Attractive design compliant with EN54-11 Test key for routine testing without breaking the glass element Protection against accidental operation via polycarbonate flap Used in the firetracker FT512, firetracker FT128 and firetracker FT1020G3 systems Intended for indoor use and in dry premises Cover optional sold separately 3339 BROOKS Enclosed Addressable Manual Call Point IP56 Encapsulated circuit Built in LED indicator Attractive design compliant with EN54-11 IP rating IP56 Test key for routine testing without breaking the glass element Protection against accidental operation Used in the firetracker FT512, firetracker FT128 and firetracker FT1020G3 systems Intended for indoor use in premises where IP56 rating is required Protection against accidental operation via polycarbonate flap 4433 BROOKS Addressable Manual Call Point with Isolator Attractive design compliant with EN54-11 Test key for routine testing without breaking the glass element Built-in short-circuit isolator Protection against accidental operation 4439 BROOKS Enclosed Addressable Manual Call Point with Isolator Attractive design & Built-in short-circuit isolator. IP rating IP56 Test key for routine testing without breaking the glass element Page10 Page 10

13 Analogue Addressable Detectors and Devices 3340 BROOKS Alarm Acknowledgement Facility Multiple detectors per module, max 5 detectors Loop module, one address per module Loop powered, no additional wiring Surface or flush mounting Multiple time setting for acknowledgement and investigation time Supplied with a flap cover to protect the unit Easy to program in Win512 / Win 128 / ELBWin Controls standard sounder base 3379 Used in firetracker FT128 with software V or higher Used in firetracker FT512 with software V or higher Used in firetracker FT1020G3 with any software 3361 BROOKS Addressable Multipurpose I/O unit Two programmable relay outputs Two programmable inputs, one is supervised for short or open circuit and used as a conventional zone input A larger number of trigger conditions are available Built-in LED indicator The unit is intended for indoor use and in dry premises (use any small IP box locally) Used in the firetracker FT512, firetracker FT128 and firetracker FT1020G3 systems 3364 BROOKS 2 Supervised Voltage Output Module External 24V supply is required via 3366 or the C.I.E Intended for indoor use and for dry environments (use any small IP box locally) Two programmable supervised voltage outputs A special fire door closing voltage output External 24V supply to 3364 is monitored via mains OK terminal Waterproof box available type 3362 Approved to AS BROOKS Addressable Short Circuit Isolator Module Intended to be surface mounted and a plastic protection cover Used in the firetracker FT512, firetracker FT128 and firetracker FT1020G3 systems Intended for indoor use and in dry premises When required, it can be mounted in a waterproof box Isolates a short circuit on a COM loop Specific fault messages to locate the short circuit across the COM loop Page11 Page 11

14 Analogue Addressable Detectors and Devices 3377 BROOKS Addressable Siren General purpose sounder that consists of a horn (incl. all electronics) and a back box, which has double cable entries Used in the firetracker FT512, firetracker FT128 and firetracker FT1020G3 systems Intended for indoor use and in dry premises High sound output but low current consumption Three tones are available: Continuous 990Hz, pulsed (intermittent) 990Hz 0.5s/0.5s, 2 tone (alternating) 990/650Hz 0.25s/0.25s 3 priority levels are available Powered off the COMS loop 4477 BROOKS Addressable Siren with Isolator General purpose sounder that consists of a horn (incl. all electronics) and a back box, which has double cable entries Used in the firetracker FT512, firetracker FT128 and firetracker FT1020G3 systems Built in short circuit isolator Intended for indoor use and in dry premises High sound output but low current consumption Three tones are available: Continuous 990Hz, pulsed (intermittent) 990Hz 0.5s/0.5s, 2 tone (alternating) 990/650Hz 0.25s/0.25s 3 priority levels are available Powered off the COMS loop 4383 BROOKS Light Indicator Low current consumption thanks to LED technology Placed between an analogue detector base and an analogue detector 2210/2211/2212 BROOKS Addressable Multipurpose Input Output Unit Addressable Multipurpose 8 input 8 relay output unit and 16 LED output Addressable Multipurpose 16 input 16 relay output unit and 16 LED output Generic Input Output Mimic Module Page12 Page 12

15 Fire Panels Conventional Ideal for all commercial, industrial and residential applications requiring a AS1670 solution. FT420 firetracker Conventional C.I.E The BROOKS firetracker FT420 is a highly integrated, highly configurable and flexible 4 to 20 zone Control and Indicating Equipment (CIE). The FT420 series is Australian designed and manufactured and tested by CISRO to meet the requirements of the AS and the AS Standards. The product with correct configuration and installation is suited to specific applications which require reliable early detection, occupant warnings and ancillary control. Dimensions: 480mmH x 450mmW x 200mmD From 4 up to 20 zones of alarm detection circuits and generic inputs from security, chemical hazard and any compatible inputs ACF controls and indicators, an external strobe circuit, a walk test and alarm devices output as standard features Complete Occupant Warning System (OWS) with speaker zoning, PA electrets microphone, multiple tones and voice messages, PA, dual strobe output and manual tone selections Standard facilities for fan controls according to the requirements of Standard AS1668 Standard facility for MDH fused circuit connection Standard interface for gas extinguishing system Optional OWS Configurations Available in 60 watt, 120 watt and 250 watt configurations By adding expansion boards, the CIE is capable of providing a complete OWS system which includes the following features: Multiple tone and voice messages - A total of ten tones and / or voice messages can be broadcasted based on the system conditions Dimensions: 920mmH x 450mmW x 220mmD Visual alarm indications - The OWS is capable of providing both audible and visual warnings in alarm conditions. Its monitored dual strobe output signals the visual indications for both alert and evacuation conditions separately Automatic tone alert system with manual tone selections (Alertcom) - Up to eight tones can be broadcasted based on the associated monitored trigger inputs or the manual selections. It can be used not only for the emergency warnings, but also for the general message broadcastings, such as the school and lunch bells. PA - Public addressing can be broadcasted to up to 16 manually selected zones or to all zones simultaneously Auxiliary audio input - Remote desktop microphone announcements or background music can be broadcasted when the dedicated control is enabled and the CIE is in quiescent conditions Simple configurations - User friendly system configuration simplifies installation and on-site servicing processes. Authorised users can configure all the system parameters easily via a PC interface Page13 Page 13

16 Conventional Detectors and Devices The BROOKS range of Conventional Detectors is manufactured by Panasonic and are available exclusively in Australia and New Zealand through your nearest BROOKS outlet BROOKS Multi Detector Photoelectric (Optical) and Thermal Combined heat smoke sensing Variable delay function Learning function and condition Low profile design Latest IC technology Used in conventional panels and in conventional zone inputs in BROOKS firetracker FT128, firetracker FT512 and firetracker FT1020G3, firetracker FT420 Used in conjunction with the 2324 conventional base Complies with AS BROOKS Photoelectric (Optical) Smoke Detector Low profile design Latest IC technology / highest reliability High-efficient optical system The smoke enters the detection chamber through an insect filter and an optical labyrinth Improves the smoke inflow but it also minimises false (nuisance) alarms Used in conventional panels and in conventional zone inputs in BROOKS firetracker FT128, firetracker FT512 and firetracker FT1020G3, firetracker FT420 Used in conjunction with the 2324 conventional base Complies with AS BROOKS Combination Heat Detector The heat detector 4318 is a conventional combination heat detector, class A1R Rate-of-rise and fixed temperature alarm levels Utilises reliable thermistor sensing element technology Used in conjunction with the 2324 conventional base The base has an alarm LED indication Latest IC technology / highest reliability Used in conventional panels zone inputs in BROOKS firetracker FT128, firetracker FT512 and firetracker FT1020G3, firetracker FT420 Used in conjunction with the 2324 conventional base Complies with AS Page14 Page 14

17 Conventional Detectors and Devices Base sold separately AU 6296AU BROOKS Enclosed Heat Detector (57⁰C - 117⁰C) IP67 Conventional fixed temperature heat detector The sensing element is a heat pick-up shield and a bimetal switch ATEX compliance Waterproof (IP67) LED on the detector (not on model 6298) illuminates when the detector goes into alarm Output for an external LED (RIL) A label holder intended for a label showing "zone number", can be mounted in the connection box Used in conventional panels firetracker FT420 and in conventional zone inputs in BROOKS firetracker FT128, firetracker FT512 and firetracker FT1020G3 The static response, class and temperature range for the enclosed detectors are: 6295 is, 57 C, class A2 S (54 to 70 C) 6296 is, 72 C, class BS (69 to 85 C) 6297 is, 87 C, class CS (84 to 100 C) 6298 is, 117 C, class ES (114 to 130 C) Complies with AS BROOKS Conventional Base Common base model 2324 is connected to a zone line input for conventional alarm points Conventional heat, smoke and multi detectors type 435x can be plugged in the base Easy to use wiring connections Output for external LED (RIL) The locking mechanism can be disabled The base is intended for indoor use and in dry premises Page15 Page 15

18 Conventional Detectors and Devices BARIL BROOKS External LED Indicator (RIL) The BROOKS range of remote indicators are available in many different models including: In Ceiling Space In Concealed Space In Duct In Lift Shaft In Room Used in conventional panels firetracker FT420 and in conventional zone inputs in BROOKS firetracker FT128, firetracker FT512 and firetracker FT1020G3 For a full range contact your nearest sales office 4375 BROOKS Heat Detector 60º Conventional heat detector Fixed temperature (static) alarm level 60⁰C, class A2 S Used in conjunction with 2324 conventional base Complies with AS Can be used with any conventional zone input 4376 BROOKS Heat Detector 80º Conventional heat detector Fixed temperature (static) alarm level 80⁰C, class B S Used in conjunction with 2324 conventional base Complies with AS Can be used with any conventional zone input Page16 Page 16

19 Fire Panels Residential Fire Systems Ideal for special housing requirements. BARFS-1 Residential Fire Panel The BROOKS BARFS-1 (single zone) Residential Fire Panels is specifically designed for residential applications. Its primary purpose is to provide reliable early warning of a developing fire so that the occupant is given the maximum time to escape to a place of safety. Fire is not just heat, consideration needs to be given to the smoke and toxic gases generated in all house fires. BROOKS recognises that residential applications require special consideration; the BARFS-1 panel must be flexible, have design integrity, be reliable and be conscious of occupant amenity. Dimensions: BARFS-1 305mmH x 305mmW x 75mmD BARFS1-MDH c/w Door Holder Supply 305mmH x 305mmW x 75mmD BARFS1-RKP Remote Keypad for BARFS-1 138mm x 128mm x 30mm The BARFS-1 panel has features that allow the occupant to use and manage the system. A remote keypad is available to provide an aesthetically pleasing unit. Enclosure: Zinc Steel 1.2mm powder coated oyster Dimensions: 305mm H x 305mm W x 75mm D Power Supply: Input Voltage V AC, 40W switch mode power supply Larger power supply 60W is available on request Standby Supply: 12V / 7AH sealed lead acid battery Nominal Voltage: 13.8V DC / 3 Amp Current Draw: 90mA single display 130mA dual display (keypad) Operating Temperature: 0⁰C to +50⁰C No. Of Alarm Zones: 1 Supervised zone circuit with discrimination between heat alarm / manual actuation and smoke alarm (priority 1 & priority 2) No. Of Devices per Zone: 15 smoke / heat alarms, or 15 MCP / sprinkler clean contact inputs, strobe modules and 4 vibration patrice modules Note: Current consumption must be calculated using battery capacity calculation sheet Compatible devices for use with the BARFS-1 are: EIB201I Ionisation Smoke Alarm no ActivFire listing for export sales only EIB206P Photoelectric Smoke Alarm AS3786 ActivFire listed EIB204T Thermal (Heat) Alarm AS EIB207V Vibration Patrice EIB208ST1 TK86 Strobe for sleeping area EIB208ST2 TK30 Strobe for living area EIB209IO Generic input / output module For more detailed specifications please refer to the BARFS-1 owners manual Please note that the 200 series alarms listed above have been specifically modified to work only with the BARFS-1 and will not work in standalone applications or with any other residential panel. Page17 Page 17

20 Fire Panels Residential Fire Systems Dimensions: BARFP6D 390mmH x 310mmW x 120mmD (with door) BARFP12D 680mmH x 320mmW x 170mmD (with door) BARFP18D 680mmH x 320mmW x 135mmD (with door) BARFP Series Residential Fire System The BROOKS (BARFP6D, BARFP6Q, BARFP12D, BARFP18D) residential fire system consists of both control and indicating equipment connected to compatible smoke/heat alarms. The system provides an automatic fire detection and alarm system designed to meet the requirements of Australian Standard AS and the Building Code of Australia (BCA). The smoke / heat alarms provide the automatic detection of fire with their integral sounder acting as the occupant warning system. Applying AS1670 design principles to a smoke alarm system enables features such as zoning and the control of ancillary devices such as door locks or hold open devices. It further allows the designer to be able to consider standby and alarm times needed for the specific application, then design the residential system to suit the application. 6, 12 or 18 Zones 12 smoke or heat alarms per zone Power Supply: Input 240V AC Output VDC, Typical mA for RFP6 A separate 1.1 Amp power supply is provided for RFP12 / RFP18 Standby Supply: 12V/ 7AH sealed lead acid battery or higher if required Battery low setting: 12.3 VDC Key switch Control: OFF / ON / FIRE System Monitoring: Wiring: loop in / loop out to smoke/heat alarms monitored by active End of Line Device Defect Mode: Initiated by an abnormal system condition: * Mains Fail * Ancillary output (common alarm) Isolated * Short circuit or open circuit line fault * System switched off Defect Output (Fault):1 set changeover dry contact Alarm Outputs: 12V DC 1 Amp maximum (not supervised) 1 set changeover dry contact Panic Input: N/O dry contact - activates all smoke/heat alarms Note: Not monitored Optional zone output card (6 relays), one relay for each zone Optional smoke / heat alarm mimic display Compatible smoke and heat alarms for use with the BARFP Series are as follows: EIPFSICX6 Ionisation Smoke Alarm EIPFSPCX6 Photoelectric (optical) Smoke Alarm EIPFSTCX6 Thermal (Heat) Alarm BA-B-RFP6 Type B RFP6 Heat Detector 60ºC BA-D-RFP6 Type D RFP6 Heat Detector 80ºC Please note that the CX6 alarms listed above have been specifically modified to work only with the BARFP range of Residential Fire Panels and will not work in standalone applications or with any other residential panel. For more detailed specifications see the BROOKS Smoke Alarm Catalogue Page18 Page 18

21 Fire Panels - Residential Fire Systems Alarm 2000 Residential Fire System for Mains Powered Alarms The Alarm 2000 is designed for small residential occupancies requiring a smoke alarm system as set out in the Building Code of Australia, but also integrates early warning with other building services. The system employs the design principles of the AS1670 standards but utilises the cost effectiveness of smoke alarms, with their combination of detection and warning sounder. The basic Alarm 2000 system can be customised and expanded to suit individual applications by the use of optional add-on modules. System Customising Integrates with other building services Full range of mains powered smoke and heat alarms Manual activation of smoke/heat alarm sounders via key switch (Fire Mode) Inputs and output Supervised circuits Optional modules: Power supervision to AS4428 Pt 5 Residential sprinkler Manual override of doors release Emergency lighting & A/C Shutdown Gas shutdown Wide range of warning devices audible/visual/hearing impaired Dimensions: Small Enclosure: Includes basic system plus 1 module 400mmH x 320mmW x 135mmD including door. One Option only of the following: Sprinkler, Ancillary, Manual Override, Gas Shutdown or Power Supervision Module. (with door) Large Enclosure: Includes basic system plus 5 module 680mmH x 320mmW x 135mmD including door. The Alarm 2000 is compatible with the following: EIPFSITL Ionisation EIPFSPTLH Photoelectric EIPFSTTL Thermal (Heat) BAVISA240 Visalert EIPFS173P Vibralarm The TL Series are mains powered with rechargeable lithium cell back-up Page19 Page 19

22 Fire Panels Local Control Panels Ideal for those smaller applications which do not require a AS1670 compliant system, such as residential warning and evacuation fire door control, sprinkler control and for use in common areas, parking areas. Local control panels are compatible with the full range of BROOKS Conventional Series of Detectors. FT2FP BROOKS Local Control Panel The BROOKS FT2FP is a 2 zone conventional CIE in a rugged metal enclosure with 003 lockable door. The FT2FP is a single control and termination module that contains the 2 zone circuits, power supply supervision inputs and outputs required for a complete 2 zone CIE. The FT2FP has been designed to meet the requirement of AS and AS Dimensions: 400mmH x 320mmW x 135mmD (with door closed) Weight: 10 Kg. (without backup battery) Intelligent microprocessor based system with reliable 2 zone fire detection Fully supervised 24V@1A output for alarm devices with separate control and indication Built-in dual power sources, very low current draw, typical 35mA on quiescent condition Intuitive indication and controls via the well-grouped LED indicators and momentary switches 2 zone fire detection with configurable latching / non latching and Alarm Verification Facility (AVF) features 2 configurable zone relay dry-contact outputs which can be activated by either the common alarm / fault conditions or the individual zone alarm conditions (DIP Switch configuration) 3 general condition dry-contact relay outputs to indicate alarm, fault and disable conditions Optional web server to provide Ethernet connectivity Compatible with the full range of BROOKS range of conventional detectors and devices FT2ESD For applications requiring a 2 stage shut down process (Specs similar to FT2GAS contact your local sales office on FIRE or visit Page20 Page 20

23 Specialised Panels and Devices FT2GAS BROOKS Gaseous Extinguising System The FT2GAS system comprises of a 2 zone conventional module (FT2) designed to meet the requirements of AS and AS to which a plug-in gas control module is added. The combination of the FT2 module and plug-in gas module is designed to comply with the Detection, Actuation and Control Systems section of AS Gaseous Fire Extinguishing Systems. The FT2GAS system provides all inputs and outputs required for monitoring and control of a gas extinguishing system including the warning signs and local control station. Compatible with the full range of BROOKS Panasonic Conventional Detectors and Devices. Dimensions: 400mmH x 320mmW x 135mmD 12 Kg. (without back-up battery) Intelligent dual microprocessor based system which combines both the two zone CIE functions and the dual zone gas control functions Fully supervised power supply and batteries The system maximum current capacity is 27.5V DC Adjustable gas release timer seconds Detection zone settings via built-in DIP switches Compatible local control station, warning signs, strobes and sounders Optional web server interface for ethernet connectivity with web pages and alert BLCS1 Local Control Station The BROOKS Local Control Station (BLCS1) is provided for the manual release and discharge inhibit of the gas extinguishing agent. The BLCS1 is interfaced to the BROOKS FT2-GAS control panel via a supervised 4 wire connection. The GAS RELEASE function provides a manual initiate switch, incorporating a two-step action which initiates the normal system discharge sequence including fire and evacuation alarms, time delays, and equipment shutdowns and overrides the discharge inhibit switch in FT2GAS. The operation of this switch has a visual indication at both the LCS and FT2GAS panel. The GAS ISOLATE function provides a discharge inhibit switch that prevents automatic discharge of the extinguishing agent; stops and resets the normal system actuation control sequence; but does not override the operation of the manual release switch. The operation of this switch causes an audible and visual indication at the LCS and a visual indication at the FT2GAS panel. The BLCS1 has been designed to be highly visible to the occupants when placed adjacent to the main emergency exit from the protected area Dimensions: 193mmL x112mmw x 61mmH Attractive design concept Built in audible warning for gas isolate Two step operation for gas release prevents accidental operation Resettable gas release control 4 supervised wires to interface to the FT2GAS No current draw in quiescent state Designed to meet the requirements of AS4214 for automatic control (BLCS1IP version for IP65 is available) Page21 Page 21

24 Specialised Panels Devices Warning Signs BWS Series The BROOKS range of warning signs are designed to meet the requirements of Australian standard AS4214. They provide a suitable visual warning in the risk area when a gas extinguishing system is installed. Designed for use with the BROOKS FT2GAS conventional 2 Zone Gas Control Panel or GAS Module Kit GASMODKIT fitted in any other approved panel. The LED based design allows for the warning sign to be configured for single line operation e.g. FIRE ALARM or DO NOT ENTER or for dual line operation with the one sign e.g. FIRE ALARM for level 1 alarm and DO NOT ENTER for a level 2 alarm. The text may be configured for flashing or steady illumination. Dimensions: 300mmL x 200mmH x 60mmD Two or four wire system to any gas control panel, only two wires required for FT2GAS Steady or flashing LED indication No current consumption in quiescent state Rugged rigid steel construction Built in warning buzzer Buzzer may be configured to steady or pulsing sound (2Hz) or disabled Option for external buzzer and buzzer mute switch Dimensions: 300mm x 200mm x 60mm Warning Signs BWS-TS-FDNE & BWS-TS-FEVAC with countdown time Dimensions: 380mmL x 200mmH x 60mmD Two wire system to the gaseous extinguishing control panel Steady or flashing light No current consumption in quiescent state Pleasant and rigid design High intensity LEDs to increase the illumination Enclosure may be used for single or dual sign An external BROOKS audio horn or speaker can be used utilising the same warning signs wiring. Built in speaker module with Alert/Evac tones and gaseous extinguishing messages Built in countdown timer module for gas release Dimensions 380mm x 200mm x 60mm Changeable tones for Australia and New Zealand use Page22 Page 22

25 Specialised Panels Devices BROOKS Modular FT2GAS for OEM applications Model - GASMODKT FT1-SB Switchboard Fire Detection System The BROOKS firetracker FT1-SB is a single zone conventional fire alarm panel, designed for specific use in non critical switchboard applications such as main switchboards and motor control panels. The BROOKS FT1-SB is designed for those switchboard applications where fire detection is required within the switchboard cabinet. utilising the leading edge in technology Microprocessor based system in both display and termination modules Easy to install, display module is housed in square enclosure to fit a standard switchboard meter cut-out 90 x 90 cm Termination module is housed in a DIN rail enclosure. This can be mounted on a DIN rail inside the cabinet Transparent protective cover for the display enclosure Fully supervised detector circuit One 24V supervised alarm output limited to 0.5Amp Two alarm changeover relay contacts Two fault changeover relay contacts One disablement (isolate) changeover relay contact Universal AC input DIN rail non battery backed switch mode power 240VAC / 1Amp For further information on OEM products please contact your nearest Sales Office Page23 Page 23

26 Occupant Warning Systems BROOKS supplies a range of Occupant Warning Systems in both standalone configurations or in modular form for incorporation into 3 rd party CIE s. The BROOKS OWS can also be incorporated into the Brooks firetracker range of analogue addressable and conventional panels. The BROOKS OWS is available in 20watt, 60watt, 120watt and 250watt versions in both standalone and modular form. BROOKS also supply a complete range of remote desk microphones with zone selection and all call, and, a complete range of speakers for indoor and outdoor use. Dimensions: 320mmW x 400mmH x 170mmD (with door closed) BROOKS Standalone OWS Easy to use visual display Digital voice messages Supervised trigger Input (short/open circuit) Supervised dual Strobe Output Supervised 100V Speaker Output Fault Relay change over contacts Fault Buzzer Output On board fault indicators for strobe output, trigger input and speaker line Standard electret microphone, input for optional dynamic microphone Microphone enable/disable switch input Auxiliary audio input (transformer isolated) for background music or remote desk microphone Auxiliary audio enable/disable switch input Communication for remote multiple zones desk microphone via RS485 Amplifier standby enable output (for lower quiescent power) Speaker zone expansion capability (up to 16 zones; individually short/open circuit monitored), requires larger enclosure Battery backup and power supply monitoring Power supply complies with AS Alert tone and message meet the requirements of ISO 7731 Evacuation tone (T3) and message meet the requirement of ISO 8201 AS tones BROOKS OWS KITS For inclusion in any C.I.E Three models of BROOKS OWS Kits are available: 60WAMPKIT 60 Watt OWS Kit 120WAMPKIT 120 Watt OWS Kit 250WAMPKIT 250Watt OWS Kit Page24 Page 24

27 Occupant Warning Systems Dimensions: 200mmL x 150mmW 48mmH (one side) 68mmH (other side) BROOKS Remote Desktop Microphones PA-1 / PA-8 / PA-16 The BROOKS series of remote desk microphones are intended for public address use in conjunction with the BROOKS OWS. Available in 3 models, single zone (PA-1), 8 zone (PA-8) and 16 zone (PA- 16). The BROOKS range of remote desk microphones is elegantly styled in a rugged metal enclosure providing excellent stability for desk top applications no annoying slippage. In addition the BROOKS units provide excellent speech intelligibility for all public address applications. In addition to the all call, the PA-8 & PA-16 allows for individual zone selection for any zone or any combination of zones. The PA microphone range also features for background music (BGM) line input socket and music input enable control. Standard configuration 1, 8 and 16 speaker zone selection Dynamic goose neck microphone with industry standard XLR connector Built-in Pre-amp Background music socket for line input connected directly to the Microphone Background music input enable control Power on and fault indicator LEDs (fault LED indicates communication or OWS fault) Powered from fire panel (battery backup) Supplied with wall mount plate and plug-in cables Individual zone selection or all call paging Requires only 6 wires from the OWS main control module, 2 for audio, 2 for 24V power and 2 for RS485 or Mic enable (PA-1) BROOKS 24V Tone/Message Sounders: B24VH - Horn Speaker B24VHD - Horn Speaker c/w Tone/Voice module for Fire Doors B24VHG Horn Speaker c/w Tone/Voice module for Gas Systems B24VSPS - Surface Mount Speaker B24VSPF - Flush Mount Speaker The BROOKS range of electronic sounders provide both tones and warning messages. The combination of tone and voice message elicits a more positive response from building occupants during an emergency. The BROOKS electronic sounder consists of a speaker / horn and digital voice/tone module which can be custom programmed for tonal frequency, voice message and language to meet specific client needs. Tones can be selected for evacuation tone T3 or 2200 tones. Page25 Page 25

28 Accessories 6377 BROOKS Duct Probe Chamber (purchase detector separately) Only one pipe is required Simple Installation For conventional as well as analogue and addressable systems o : UG-4 pipe 0.6 m. o : UG-4 pipe 1.5 m incl. plastic end gasket and rubber gasket TET o : UG-4 pipe 2.8 m incl. plastic end gasket and rubber gasket TET ) o 6384: UG-4 filter (10 pieces) B & B Supply Air Controller Supervised detector circuit Output for remote indicator (RIL). Facility for ALARM and FAULT TEST Indicators for Power, Controller Status, Alarm and Fault Alarm Output - relay change over contacts rated at 240Vac / 5A. Fault Output - Relay Contact rated at 30V / 1A Auxiliary Output Supply (Fused 24Vdc 250mA). Cable glands supplied as standard. (cables 6-12mm diameter) Available in 24VDC and 240VAC versions BPSU5 5 Amp Standalone Power Supply Fully supervised power supply Power supply supervision module complies with AS Local sounder for fault warning with mute facility Standard unit supplied with 5.5A switch mode power supply Clean changeover contacts for power supply fault and for power fail Meets the requirements of AS3000 Space for 2x7AH or 2x12AH sealed lead acid batteries Dimensions: 330mmH x 320mmW x 125mmD BLINK 240 / BLINK 12 Interlinkerator Output to trigger BROOKS 240V smoke / heat alarms (BLINK-240) or 12V smoke / heat alarms (BLINK-12) Operates of 24V or 12V DC input High intensity LEDs to attract the occupant s attention Minimal current consumption in quiescent state Drives up to 40 BROOKS smoke or heat alarms Easy and simple to mount Page26 Page 26

29 Accessories and Sight and Sound Products BLCS-IPBOX IP Enclosed c/w with hinged window for IP BLCS1 BWS-IPBOX IP Enclosed c/w Bracket for IP Warning Signs 6360 Protective Cover for Detector Protection against physical damage Protection against theft 6218 Drip Pan for Detector Protection against damp / moisture A wide range of sight and sound accessories products to suit BROOKS fire systems are available Consisting of sounders, speakers, strobes, sounder/strobe combinations, bells, fire labels, interfaces and much more For further information on sight and sound products please contact your nearest Sales Office Look out for our NEW SIGHT AND SOUND CATALOGUE OUT SOON! Intrinsically Safe Detectors and Devices BROOKS offer an extensive range of Intrinsically Safe Detectors and Ancillary Devices, as requirements and standards vary per application then please contact your nearest BROOKS Sales Office or call (FIRE) to further discuss your application. Page27 Page 27

30 Fire Industry Acronyms AAF: AD: ACF: AI: AHU: AIF: AIM: ANN: ASD: ASE: AVF: BGA: BLDG: BOWS: BVS: C.I.E: CS: E.W.I.S: EWS: ELD: EOL: EPU: F.I.P: FBP: FFC: FFF: FLR: Alarm Acknowledgment Facility Addressable Device Ancillary Control Facilities Artificial Intelligence Air Handling Unit Alarm Investigation Facility Alarm Investigation Module Annunciator Panel Aspirated Smoke Detector Alarm Signaling Equipment Alarm Verification Facility Break Glass Alarm Building Building Occupant Warning System Booster Valve Set Control Indicating Equipment Concealed Space Emergency Warning & Intercommunication System Emergency Warning System End of Line Device End Of Line External Presentation Unit Fire Indicating Panel Fire Brigade Panel Fire Fan Control Fire Fighting Facility Floor FS: Flow Switch G: Gas Fire Detector LVL: Level MCP: Manual Call Point MDH: Magnetic Door Holder MECP: Master Emergency Control Panel MV: Monitored Value OWS: Occupant Warning System PS: Pressure Switch RCE: Remote Control Equipment RDU: Remote Display Unit RIL: Remote Indicator Light RP: Repeater Panel RVI: Remote Visual Indicator S.F.I.P: Sub Fire Indicating Panel SAF: Supply Air Fan SECP: Secondary Emergency Control Panel SMK: Smoke SPF: Stair Pressurisation Fan SPK: Speaker SPL: Sound Pressure Level SIP: Sub Indicator Panel SSF: Smoke Spill Fan TS: Tamper Switch VESDA: Very Early Smoke Detection Apparatus Page28 Page 28

31 Fire Terms Glossary Addressable Device A fire alarm system component with discreet identification that can have its status individually identified, or that is used to individually control other functions Alarm Signal A signal indicating an emergency requiring immediate action, such as a fire alarm signal Analogue Initiating Device An initiating device that transmits a signal indicating varying degrees of condition, such as smoke obscuration level. As contrasted with a conventional initiating device which can only indicate an on / off condition Annunciator A unit containing two or more indicator lamps, alphanumeric displays, or other equivalent means in which each indication provides status information about a circuit, condition, or location Automatic Fire Detectors A device designed to detect the presence of fire or the products of combustion. Including but not limited to, heat detectors, smoke detectors, and beam detectors Central Station Fire Alarm System A system or group of systems in which the operations of circuit s devices are transmitted automatically to, recorded in, maintained by, and supervised from a central station Control Panel An electrical device which switches, buttons, lights, or displays, used to monitor and control other devices or equipment Evacuation Signal Distinctive signal intended to be recognised by the occupants as requiring evacuation of the premises Exit Plan Plan for the emergency evacuation of the premises Fire Alarm A system that detects and reports a fire in the protected area, detects and reports water flowing in a sprinkler system, or detects and reports dangerous conditions such as smoke or overheated materials that may combust Fire Alarm Control Panel A Fire System component that receives inputs from automatic and manual fire alarm devices and may supply power to detection devices and transponders or off the area transmitters. The control unit may also provide transfer condition of relays or devices connected to the control unit. The fire alarm control panel can be a local unit or a master control unit Four Wire Smoke Alarm Detector A smoke detector which initiates an alarm condition on two separate wires apart from the two wires that is for power Heat Detector A device that detects abnormally high temperature or a rate of temperature increase Page29 Page 29

INTELLIGENT MONITORING FOR SAFER BUSINESS

INTELLIGENT MONITORING FOR SAFER BUSINESS INTELLIGENT MONITORING FOR SAFER BUSINESS PANASONIC FIRE ALARM SOLUTIONS TECHNOLOGY FOR A BETTER WORKING WORLD CHOOSE PANASONIC FIRE SOLUTIONS AND YOU RE CHOOSING WORLD-CLASS PROTECTION With more than

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10 TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

Conventional Fire Detection and Extinguishant Control System Specification

Conventional Fire Detection and Extinguishant Control System Specification Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

Fire alarm system EBL512 G3

Fire alarm system EBL512 G3 Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Generation three G3. Internet: pesn.panasonic.se 2011-03-24 Page 1 of 6 The demands

More information

Premier M Plus & Infinity 8

Premier M Plus & Infinity 8 25 Years of Manufacturing Excellence Premier M Plus & Infinity 8 Conventional Fire Alarm Systems 007 Assessed to ISO 9001: 2008 Certificate number 330 Premier M Plus 8-24 Zone Conventional Fire Alarm Panel

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

INTELLIGENT MONITORING FOR SAFER BUSINESS PANASONIC FIRE ALARM SOLUTIONS

INTELLIGENT MONITORING FOR SAFER BUSINESS PANASONIC FIRE ALARM SOLUTIONS INTELLIGENT MONITORING FOR SAFER BUSINESS PANASONIC FIRE ALARM SOLUTIONS TECHNOLOGY FOR A BETTER WORKING WORLD CHOOSE PANASONIC FIRE SOLUTIONS AND YOU RE CHOOSING WORLD-CLASS PROTECTION With more than

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19 TECHNICAL SPECIFICATIONS Page 1 of 19 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC analogue addressable, electrically supervised, zone annunciated, fire detection and alarm system as

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types

More information

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: eda@electrodetectors.co.uk

More information

DTW Works Master Specification Version 2006

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

AlarmSense 2-wire detection and alarm system. Product Guide

AlarmSense 2-wire detection and alarm system. Product Guide AlarmSense 2-wire detection and alarm system Product Guide Contents What is AlarmSense? 2 The purpose of AlarmSense 4 How AlarmSense works 4 Alarmsense Features 5 Detector removal monitoring 5 Priority/non-priority

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One

More information

PLAN REVIEW GUIDE FOR FIRE ALARM

PLAN REVIEW GUIDE FOR FIRE ALARM PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical

More information

welcome to our world fire alarm systems - series 600 www.staticsystems.co.uk

welcome to our world fire alarm systems - series 600 www.staticsystems.co.uk Static Systems Group PLC Heath Mill Road, Wombourne Staffordshire WV5 8AN. United Kingdom. Tel: +44 (0) 1902 895551 Fax: +44 (0) 1902 324969 www.staticsystems.co.uk welcome to our world In line with our

More information

Planning Instructions MEW01351 Revision -

Planning Instructions MEW01351 Revision - Planning Instructions MEW01351 Revision - Fire Alarm System EBL512 G3 V1.1.x Author: Jan Pettersson Date of issue: 2011-02-11 Date of rev: This page has deliberately been left blank. Table of contents

More information

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:

More information

MINERVA MX MX Virtual Multi-Sensor Detectors

MINERVA MX MX Virtual Multi-Sensor Detectors DATASHEET MINERVA MX MX Virtual Multi-Sensor Detectors Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Optional bi-directional

More information

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Fire. The Fire Installers Mate. A guide to fire alarm systems design Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

ACTIVE 5 ENGINEERING MANUAL

ACTIVE 5 ENGINEERING MANUAL ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features

More information

Analogue addressable devices

Analogue addressable devices Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet

More information

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

TS510 & TS500. Installation & User Guide. Compatible Equipment

TS510 & TS500. Installation & User Guide. Compatible Equipment Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction

More information

500r+ Installation and User Guide

500r+ Installation and User Guide 500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and

More information

CB200W Water Leak Detection Panel Application Guide

CB200W Water Leak Detection Panel Application Guide Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical

More information

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT

More information

Triple Waveband Infra-Red Flame Detection

Triple Waveband Infra-Red Flame Detection Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval. Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's

More information

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment

More information

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's

More information

Fire Detection Product Range

Fire Detection Product Range Fire Detection Product Range World Leading Fire Detection Products from the NITTAN group Issue 1.0 Business Overview The Nittan Group has been at the forefront of the fire protection industry since 1954

More information

Fire detection equipment

Fire detection equipment PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,

More information

9452/9453 Installation and User Guide

9452/9453 Installation and User Guide 9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay

More information

INSTALLATION MANUAL PC2525. Version 1.1

INSTALLATION MANUAL PC2525. Version 1.1 INSTALLATION MANUAL PC2525 Version 1.1 TABLE OF CONTENTS FEATURES 1 SPECIFICATIONS 1 INSTALLATION 2 Mounting the Panel... 2 Mounting the Keypad... 2 Auxiliary Power Connection... 2 Bell/Siren Connection...

More information

Planning Instructions MEW00227 Revision 2

Planning Instructions MEW00227 Revision 2 Planning Instructions MEW00227 Revision 2 Fire Alarm System EBL512 V2.1.x Author: Jan Pettersson Date of issue: 2002-02-25 Date of rev: 2002-12-16 This page has deliberately been left blank. Table of contents

More information

Users Guide to Keypad Functions

Users Guide to Keypad Functions Users Guide to Keypad Functions MANUAL NO. 700-175-01J ISSUED JAN 2002 VERSION 1.41 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Panic Fire Medical Away Arm Stay Arm Stay Arm &

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

PowerGem Pro Uninterruptible Power Supply

PowerGem Pro Uninterruptible Power Supply Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

Voice alarm system E100 the new standard for safe evacuation

Voice alarm system E100 the new standard for safe evacuation Voice alarm system E100 the new standard for safe evacuation Clear announcements and future-proof protection in case of fire Answers for infrastructure. E100 from Siemens so everyone knows what to do when

More information

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems P R E V E N T L O S S I O N C E R T I F I C AT LPCB B O A R D I O N Cooper Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work GE Security Small Building Life Safety Solutions Affordable FireShield Conventional Fire Alarm Control Panels imagination at work cost Location: Environment: Solution: Flower shop Finely decorated, gentle

More information

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system FIRE ALARM SYSTEM reliable fire detection and alarm signalling system Satel fire alarm devices allow to implement reliable and modern systems responsible for fire safety. A combination of 20-year experience

More information

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM 1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this

More information

Repeaters and Mimics Data Sheet

Repeaters and Mimics Data Sheet Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications Gen4 Intruder Alarm Panels SIMPLY SECURE For Residential & Small Commercial Applications Overview and features 8 Zones Each one is separately identified on the keypad and provides ample security detection

More information

GSM ALARM SYSTEM USER MANUAL

GSM ALARM SYSTEM USER MANUAL GSM ALARM SYSTEM USER MANUAL 1. Instruction The alarm system is based on GSM network. With a GSM SIM card, it can be used wherever you want and no need to connect any wire, which is convenient and easy

More information

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS Wireless - Emergency Alert Systems Easy installation - Wireless Radio System no wires or wiring required Evacuation, Alert & Lockdown all in one system S.O.S Assist - up to 6 unique SOS assistance zone

More information

HART HSSD High Sensitivity Smoke Detection

HART HSSD High Sensitivity Smoke Detection HART HSSD High Sensitivity Smoke Detection The HART High Sensitivity Smoke Detection system (HSSD) is an Aspirating Smoke Detection system (ASD) designed to give very early indication of an incipient

More information

CFP 2/4/8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL. user manual & log book. Approved Document No. DFU7001020 Rev 1

CFP 2/4/8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL. user manual & log book. Approved Document No. DFU7001020 Rev 1 CFP 2/4/8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL user manual & log book Approved Document No. DFU7001020 Rev 1 CONTENTS Safety...3 Important information regarding the safe use of this fire alarm panel

More information

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual P/N 315-049403-1 Siemens Building Technologies Fire Safety Table Of Contents Introduction...1 The Access levels...1 User Level...1 Maintenance

More information

SMART SENSOR COLLECTION

SMART SENSOR COLLECTION TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8

More information

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

Module 5. Fire and Emergency Alarm System Part I- Basics

Module 5. Fire and Emergency Alarm System Part I- Basics Module 5 Fire and Emergency Alarm System Part I- Basics 1 This module will describe: 1. Components and the arrangements of components in fire and emergency alarm systems. 2. How these systems work. 3.

More information

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance

More information

CBD-233. Fire Alarm and Detection Systems

CBD-233. Fire Alarm and Detection Systems Page 1 of 5 CBD-233. Fire Alarm and Detection Systems Originally published August 1984. R.H.L. McEwen Fire alarm systems are normally required by building codes. In the case of new buildings, this is usually

More information

www.ealarm.com.my P/N 5-051-371-00 Rev D

www.ealarm.com.my P/N 5-051-371-00 Rev D System 236 System 236i P/N 5-051-371-00 Rev D Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced alarm systems on the market today, designed to provide

More information

Global System Technology(UK) PLC The Intelligent Solution

Global System Technology(UK) PLC The Intelligent Solution Global System Technology(UK) PLC The Intelligent Solution MANUFACTURED IN ACCORDANCE WITH Intelligent Photoelectric Smoke Detector Aesthetically pleasing Low profile design 8 Bit intelligent processor

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

Fire Alarm Control Panel. Family. Operating Manual

Fire Alarm Control Panel. Family. Operating Manual Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...

More information

How To Use A Ds340 (Dsp)

How To Use A Ds340 (Dsp) Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services

Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services General Information Section 6 of AS1851-2012 covers: Fire Detection and Alarms Systems Electrical Detection

More information

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance

More information

User Guide for the DS7060 Control/Communicator

User Guide for the DS7060 Control/Communicator DS7060 User Guide Copyright 1996-97 Detection Systems, Inc. User Guide for the DS7060 Control/Communicator Copyright 1996-97 Detection Systems, Inc. Detection Systems, Inc., 130 Perinton Parkway, Fairport,

More information

Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide

Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide Contents Page 1.0 Introduction and Typical System Illustration 2 2.0 Cabinet Specifications 4 3.0 Hardware Specifications 7 4.0 Software

More information

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008 Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy. Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

User manual Rev 1.3 Contents

User manual Rev 1.3 Contents User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6

More information

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as

More information

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this

More information

NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL

NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL NESS D16 16 Zone Control Panel and Dialler OWNER S MANUAL REVISION 2, JULY 2001 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia

More information

IDS X-Series User Manual 700-398-01D Issued July 2012

IDS X-Series User Manual 700-398-01D Issued July 2012 1 2 Contents 1. Introduction to the IDS X-Series Panels... 7 2. Before Operating Your Alarm System... 7 3. Understanding the Keypad LEDs... 8 3.1 Viewing Data on an LED Keypad... 12 3.1.1 LED Status Indicators...

More information

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual SUPA8 Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS... 1 INSTALLATION OF THE SECURITY SYSTEM... 2 COMMISSIONING THE DIALLER PANEL... 5 ZONE INPUT CONNECTIONS... 7 PANEL

More information

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen) Safely into a new day Advanced modular FIRE ALARM CONTROL PANEL with additional functionality NJP-400A NJP-401A I m on FIRE (Bruce Springsteen) EN 54-2, EN 54-4 Cert No. 1124a DESCRIPTION OP-400A, NJP-400A,

More information

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839 AVAILABLE TO DOWNLOAD ON THE APOLLO APP a guide to Fire Alarm Systems Design BS5839 Part1:2013 The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply! What

More information

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Software Versions: PANEL 1.52 & LOOP CARD 2.0 ONE TO FOUR LOOPS ANALOGUE ADDRESSABLE FIRE ALARM PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK #Doc No. GLT.MAN-135 TABLE OF CONTENTS WHAT TO DO IF THE

More information

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM KNOXVILLE, TENNESSEE SECTION 28 31 11 PAGE 1 PART 1 - GENERAL 1.01 DESCRIPTION OF WORK SECTION 28 31 11 A. Extent of fire alarm and detection system work shall be as described in this specification, as

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version) NetworX Series NX- 4/8 Code Pad User Manual (Australian Version) Table Of Contents Code Pad Diagram... Inside Front Glossary of Terms...2 Understanding the Code Pad lights...3 Code Pad Tones...4 Fully

More information