NATILUS. Smallcut Plate System. NATİLUS SMALLCUT PLATE SYSTEM Smallcut Locking Plate Smallcut Dynamic Plate. Features. Indications.

Size: px
Start display at page:

Download "NATILUS. Smallcut Plate System. NATİLUS SMALLCUT PLATE SYSTEM Smallcut Locking Plate Smallcut Dynamic Plate. Features. Indications."

Transcription

1 NATILUS Smallcut Plate System Retractor Canal Radial Fit Low Contact Locking Options Dynamic Options Dynamic Compression NATİLUS SMALLCUT PLATE SYSTEM Smallcut Locking Plate Smallcut Dynamic Plate Natilus Smallcut plate system is a minimal invasive system. Additionally Natilus Smallcut Plate System is more stable than traditional plate systems. In traditional plate systems the loading is perpendicular to the screws, but in Natilus Smallcut System the loading is less ten 90 degrees. That means less bending force at screws and the plate. So early load bearing is available in Natilus Smallcut Plate system Features Small incision is needed for application More stable than traditional plates MRI compatibility Less bending force on the plate Canals in the ends for skin retractor Radial anatomic fit Site canal - low contact surface combination Site canals for multipurpose use Unique plate tips for easy application Dynamic compression ability Locking screw application in locking plates Dynamic loading in dynamic plates Unique screw tip for self drilling and tapping Percutenous screw application Indications Stabilization of long bones; Femur, tibia, humerus, radius, ulna... Contraindications İnfection Severe osteoporotic bone Metal sensitivity Smallcut Incision Psychiatric conditions that patient can not cooperate. Smallcut means small incision for the application

2 Specifications to to to Natilus Smallcut Dynamic Plate 3mm (Stainless Steel) Natilus Smallcut Dynamic Plate 4mm (Stainless Steel) Natilus Smallcut Dynamic Plate 5mm (Stainless Steel) to to to Natilus Smallcut Locking Plate 3mm (Stainless Steel) Natilus Smallcut Locking Plate 4mm (Stainless Steel) Natilus Smallcut Locking Plate 5mm (Stainless Steel) to to to Natilus Normalcut Locking Plate 3mm (Stainless Steel) Natilus Normalcut Locking Plate 4mm (Stainless Steel) Natilus Normalcut Locking Plate 5mm (Stainless Steel) to to to Natilus Normalcut Dynamic Plate 3mm (Stainless Steel) Natilus Normalcut Dynamic Plate 4mm (Stainless Steel) Natilus Normalcut Dynamic Plate 5mm (Stainless Steel) to to to to to to to to to to to to to to to to VS Metric Screw Ø5mm x 20mm to 70mm (SS) VS Metric Locking Screw Ø5mm x 20mm to 70mm (SS) VS Cortical Screw Ø5mm x 20mm to 70mm (SS) VS Cortical Locking Screw Ø5mm x 20mm to 70mm (SS) VS Metrik Screw Ø4.5mm x 16mm to 70mm (SS) VS Metric Locking Screw Ø4.5mm x 16mm to 70mm (SS) VS Cortical Screw Ø4.5mm x 16mm to 70mm (SS) VS Cortical Locking Screw Ø4.5mm x 16mm to 70mm (SS) VS Metrik Screw Ø3.5mm x 10mm to 50mm (SS) VS Metric Locking Screw Ø3.5mm x 10mm to 50mm (SS) VS Cortical Screw Ø3.5mm x 10mm to 50mm (SS) VS Cortical Locking Screw Ø3.5mm x 10mm to 50mm (SS) VS Metrik Screw Ø2.7mm x 10mm to 40mm (SS) VS Metric Locking Screw Ø2.7mm x 10mm to 40mm (SS) VS Cortical Screw Ø2.7mm x 10mm to 40mm (SS) VS Cortical Locking Screw Ø2.7mm x 10mm to 40mm (SS) Headquarters: Metroport Busidence No :143, E5 Üzeri Kültür Sokak No: 1, Bahcelievler / Istanbul E- mail: info@spinamer.com R&D Department: Yildiz Technical University Davutpasa Campus, Technology Development Zone B2 Block, No: 14, Esenler / Istanbul research@spinamer.com Factory: Sanayi Mah Sok. No: Esenyurt / Istanbul Tel: Fax: factory@spinamer.com Supported by kosgeb R00 Design 2013 ahmed helmy Printed by Erkam Yayın San. Mam. ve Bilgisayar Ürün İm. Tic. A.Ş

3 OrtoVia External Fixator System Practically Stable Modularity Smart 3D joint Joint Cancelling Easy Pin Holding Multiaxis Pin Insertion Unique Pin Tip ORTOVIA 3D Lower Extremity Fixator System ORTOVIA 3D Fixator System is a series of modular monolateral external fixator that was developed under many years of clinical experience. Features Modularity Easy application Short surgery time MRI compatability Flexibility - Versatility Stability & safety in corrections Patient s comfort Radiolucent components Short learning curve Fixator Modules: Adult Fixator: Clamp : Metaphysis Clamp, Poly Clamp, Sliding Clamp, Half Sliding Clamp. Joint : 3D Joint, BS Joint Body : L20, L25, L30 Pediatric Fixator: Clamp : Pediatric Metafiz Clamp, Pediatric Sliding Clamp Joint : Pediatric 3D, Pediatric BS Joint Distractor : P15, P20, P25 Indications Short Stature Bone loss Open fractures Comminuted fractures Non-union Angular deformities Limb reconstruction

4 Specifications ORTOVIA FIXATOR VIAFIX FIXATOR ORTOVIA Fixator Body L20 ORTOVIA Fixator Body L25 ORTOVIA Fixator Body L30 ORTOVIA Slindig Clamp ORTOVIA Half Slindig Clamp ORTOVIA Methaphisis Clamp ORTOVIA LS2O ORTOVIA L20 ORTOVIA L25 ORTOVIA L30 ORTOVIA LS ORTOVIA R20 ORTOVIA R25 ORTOVIA R30 ORTOVIA RS VIAFIX Fixator Short Body VIAFIX Fixator Medium Body VIAFIX Fixator Long Body VIAFIX Sliding Clamp VIAFIX Poly Clamp VIAFIX Mono Clamp VIAFIX Fixator Rod 150mm VIAFIX Fixator Rod 200mm VIAFIX Fixator Rod 250mm VIAFIX Fixator Rod 300mm VIAFIX Fixator Ball-Socket Joint VIAFIX Fıxator Hinge-Joint VIAFIX Fixator Connector-joint VIAFIX D Fixator Short VIAFIX D Fixator Medium VIAFIX D Fixator Long VIAFIX DT Fixator VIAFIX D Hip Clamp Headquarters: Metroport Busidence No :143, E5 Üzeri Kültür Sokak No: 1, Bahcelievler / Istanbul E- mail: info@spinamer.com R&D Department: Yildiz Technical University Davutpasa Campus, Technology Development Zone B2 Block, No: 14, Esenler / Istanbul research@spinamer.com Factory: Sanayi Mah Sok. No: Esenyurt / Istanbul Tel: Fax: factory@spinamer.com Supported by kosgeb R00 Design 2013 ahmed helmy Printed by Erkam Yayın San. Mam. ve Bilgisayar Ürün İm. Tic. A.Ş

5 ANT SCREW ANT SCREW SYSTEMS Multifunction Screws Dual Threads Augmentation Hole Anchor Use Cannulated Options Percutaneous Options Unique Tip ANT SCREW SYSTEMS Canulated screw Percutenous solid screws FEATURES: Designed to stabilize bone fragments. Threaded head provides interfragmentary compression. Threaded conical head design minimizes hardware prominence and soft tissue irritation. Ability of soft tissue augmentation by the hole on the head. Ability of wire augmentation via the hole on the head to fix the fragments. Self driling and tapping ability. INDICATIONS: Alignment and stabilization of bone fractures; such as wrist,elbow,foot,ankle,k nee,patella,hip,etc. Nonunions and malunions Ligament reconstruction. Arthrodesis of the foot,ankle,wrist,elbow and hand. Agumentation of fracture fixation by wire or cable via the hole on the head CONTRAINDICATIONS: Active infection Patient conditions including blood supply limitations, Insufficient quantity or of bone Patients with mental or neurologic conditions who are unwilling or incapaple of following postoperative care instructions. Foreign body sensitivity.

6 Specifications SCREW SIZES: Shaft / thread : lenght 1.6 / 2.5mm: mm in 2mm increment in lenght. 2.0 / 3.0mm: mm in 2mm increment in lenght. 2.5 / 3.5mm: mm in lenght with 2 mm increment and 50-70mm with 5mm increment. 3.5 / 4.5mm: mm in lenght, 20-50mm with 2mm and mm with 5mm increment. 4.5 / 6.5mm: mm in lenght, 16-30mm with 2mm increment and mm with 5mm. Both canulated and uncanulated screws are avalable. Presented as microant and ANT Screw set: microant Screw set: 1.6 / 2.5mm screws 2.0 / 3.0mm screws 2.5 / 3.5mm screws Both canulated and solid ANT Screw set : 3.5 /4.5mm screws 4.5/6.5mm screws Both canulated and solid ANT Screws and microant Screws to to to to to to ORTOVIA Ant Solid Screw 20mm to 100mm Ø4.5mm (Ti) ORTOVIA Ant Cannulated Screw 20mm to 100mm Ø4.5mm (Ti) ORTOVIA Ant Solid Screw 20mm to 120mm 25mm Thread Ø6.5mm (Ti) ORTOVIA Ant Cannulated Screw 20mm to 120mm 25mm Thread Ø6.5mm (Ti) ORTOVIA Ant Solid Screw 75mm to 120mm 35mm Thread Ø6.5mm (Ti) ORTOVIA Ant Cannulated Screw 75mm to 120mm 35mm Thread Ø6.5mm (Ti) to to to to to to ORTOVIA microant Solid Screw 16mm to 30mm Ø2.5mm (Ti) ORTOVIA microant Cannulated Screw 16mm to 30mm Ø2.5mm (Ti) ORTOVIA microant Solid Screw 16mm to 30mm Ø3.0mm (Ti) ORTOVIA microant Cannulated Screw 16mm to 30mm Ø3.0mm (Ti) ORTOVIA microant Solid Screw 16mm to 30mm Ø3.5mm (Ti) ORTOVIA microant Cannulated Screw 16mm to 30mm Ø3.5mm (Ti) Headquarters: Metroport Busidence No :143, E5 Üzeri Kültür Sokak No: 1, Bahcelievler / Istanbul E- mail: info@spinamer.com R&D Department: Yildiz Technical University Davutpasa Campus, Technology Development Zone B2 Block, No: 14, Esenler / Istanbul research@spinamer.com Factory: Sanayi Mah Sok. No: Esenyurt / Istanbul Tel: Fax: factory@spinamer.com Supported by kosgeb R00 Design 2013 ahmed helmy Printed by Erkam Yayın San. Mam. ve Bilgisayar Ürün İm. Tic. A.Ş

7 ACONDA DC Dynamic Screw System Stabilize Your Dynamic Compression Dynamic Compression Locked DC Cannulated Option Headless Design Self Drillingtapping Percutenous Application ACONDA DC SCREW 1. Cannulated 2. Percutanous Stalize your dynamic compression Insufficient quantity or quality of the bone Patients with mental or neurological disability Foreign body sensitivity. Features: Available in cannulated and percutaneous solid screws. Designed to stalize large bone fragments. Threaded sleeve helps interfragmentary compression Threaded sleeve strengthens the screw stabilization Dynamic compression of the fragments Stabilization of dynamic compression Headless design minimizes soft tissue irritation Self drilling and tapping ability Material: Titanium alloy, stainless steel. Indications: Alignment and stabilization of large bone fragments Stabilization of periarticular fractures of large joints Nonunions or malunions of large bone fragments Arthrodesis of large joints; foot, knee, ankle, elbow Contraindications Small bone fragmens Active infection in surgical area Systemic contraindications for the surgery

8 Specifications Implant Specifications: Consist of 3 parts: 1. Sleeves: Threaded outer surface Diameter: 9.0mm 25mm and 32mm in lenght 2. Lag screws: Cannulated and percutaneous solid obtions Diameter: 6.5mm Lenght: 70,75,80,85,90,95,100,105,110,115,120,125,130 mm 3. Sleeve-stop screw: Fixes lag screw to sleeve ORTOVIA Aconda DC Screw to to to to to to to to ORTOVIA Aconda DC Screw Ø6.5mm x50 mm to 130mm (Stainless Steel) ORTOVIA Aconda DC Screw Ø6.5mm x50mm to 130mm (Titanium) ORTOVIA Aconda DC Screw Ø4.5mm x50mm to 100mm (Stainless Steel) ORTOVIA Aconda DC Screw Ø4.5mm x50mm to 100mm (Titanium) ORTOVIA Aconda DC Cannulated Screw Ø6.5mm x50 mm to 130mm (S. Steel) ORTOVIA Aconda DC Cannulated Screw Ø6.5mm x50mm to 130mm (Titanium) ORTOVIA Aconda DC Cannulated Screw Ø4.5mm x50mm to 100mm (S. Steel) ORTOVIA Aconda DC Cannulated Screw Ø4.5mm x50mm to 100mm (Titanium) ORTOVIA Aconda Sleeve Ø9.0mm x 32mm (Stainless Steel) ORTOVIA Aconda Sleeve Ø9.0mm x 32mm (Titanium) ORTOVIA Aconda Sleeve Ø9.0mm x 25mm (Stainless Steel) ORTOVIA Aconda Sleeve Ø9.0mm x 25mm (Titanium) Headquarters: Metroport Busidence No :143, E5 Üzeri Kültür Sokak No: 1, Bahcelievler / Istanbul E- mail: info@spinamer.com R&D Department: Yildiz Technical University Davutpasa Campus, Technology Development Zone B2 Block, No: 14, Esenler / Istanbul research@spinamer.com Factory: Sanayi Mah Sok. No: Esenyurt / Istanbul Tel: Fax: factory@spinamer.com Supported by kosgeb R00 Design 2013 ahmed helmy Printed by Erkam Yayın San. Mam. ve Bilgisayar Ürün İm. Tic. A.Ş

9 ACONDA Pediatric Modular Hip Plate Modularity Minimaly Invasive Cannulated Lag Screw Adjustable Angle Trochanter Fixation Low Contact Surface ACONDA PEDIATRIC HIP PLATE SYSTEM Smallcut Locking Plate Smallcut Dynamic Plate Aconda Pediatric Hip Plate System fixes proximal femur in children sizes. The system has smallcut locking and dynamic models. Both titanium and stainless steel made models are available Features: Modularity Minimaly invasive Trochanter major fixation Adjustable plate angle Radial fit Unique plate tip Low contact surface Conical and low profile Dynamic and locking obtions Cannulated lag screw obtions Unique Screws with unique tip. Osteopenic bone Nonunions or malunions Contraindicated: İnfection of surgical region Severe osteoporosis and avascular necrosis Psychological conditions that the patient can not tolerate the postoperative regulation Metastatic or malignant disasees of the surgical area İndications: Indicated for fixation of proxiaml femur in children: Fractures of the trochanteric region: Osteotomies of the proximal femur Metastatic fracture of the proximal femur

10 Specifications ACONDA Pediatric Plate to to to to to to to to Dynamic Screw Ø4.0mm to to Locking Screw Ø4.5mm to to Locking Lag Screw Ø5.0mm ORTOVIA Aconda Pediatric Smallcut Dynamic Hip Plate 4mm (Stainless Steel) ORTOVIA Aconda Pediatric Smallcut Dynamic Hip Plate 4mm (Titanium) ORTOVIA Aconda Pediatric Smallcut Locking Hip Plate 4mm (Stainless Steel) ORTOVIA Aconda Pediatric Smallcut Locking Hip Plate 4mm (Titanium) ORTOVIA Aconda Pediatric Normocut Locking Hip Plate 4mm (Stainless Steel) ORTOVIA Aconda Pediatric Normocut Locking Hip Plate 4mm (Titanium) ORTOVIA Aconda Pediatric Normocut Dynamic Hip Plate 4mm (Stainless Steel) ORTOVIA Aconda Pediatric Normocut Dynamic Hip Plate 4mm (Titanium) VS Cortical Screw Ø4mm x 16mm to 42mm (Stainless Steel) VS Cortical Screw Ø4mm x 16mm to 42mm (Titanium) Ascends 2mm till 42mm VS Locking Cortical Screw Ø4.5mm x 20mm to 60mm (Stainless Steel) VS Locking Cortical Screw Ø4.5mm x 20mm to 60mm (Titanium) Ascends 5mm till 60mm to to to to Locking Lag Screw Ø5.0mm x 30mm to 100mm (Stainless Steel) Locking Lag Screw Ø5.0mm x 30mm to 100mm (Titanium) Locking Cannulated Lag Screw Ø5.0mm x 30mm to 100mm (Stainless Steel) Locking Cannulated Lag Screw Ø5.0mm x 30mm to 100mm (Titanium) Ascends 5mm till 100mm Specifications: Plate: Angled plate with 100 degrees. Plate bending site Trochanter major fixation canal Low contact surface Anatomic radial fit Unique tip for skin retractor Smallcut or normalcut options Dynamic or locking shaft holes Plate Sizes: 2,3,4,5,6-holes Lenght: 30,35,40.,90,95,100mm 4.5mm Locking Cortical Screw: 4.5mm locking cortical screw with 110 degree Lenght: 20,25,30,.60mm Unique screw tip for self drilling and tapping 4.0mm Cortical Shaft Screw: Locking or dynamic screw Lenght: 16,18,20 42mm Unique screw tip for self drilling and tapping Lag Screw: 5mm locking lag screw 115 degree to long part of the plate Cunnulated option Headquarters: Metroport Busidence No :143, E5 Üzeri Kültür Sokak No: 1, Bahcelievler / Istanbul E- mail: info@spinamer.com R&D Department: Yildiz Technical University Davutpasa Campus, Technology Development Zone B2 Block, No: 14, Esenler / Istanbul research@spinamer.com Factory: Sanayi Mah Sok. No: Esenyurt / Istanbul Tel: Fax: factory@spinamer.com Supported by kosgeb R00 Design 2013 ahmed helmy Printed by Erkam Yayın San. Mam. ve Bilgisayar Ürün İm. Tic. A.Ş

11 HyperFlex Spinal System HyperFlex Flexible Stability Modularity Polyaxial Screw Monoaxial Screw Hyperflex Screw Cannulated Screw Reduction Screw MONOPOLY SPINAL SYSTEM (Adult Set) The system has modular design: Polyaxial, monoaxial, reduction and cannulated screws are represented as tulip head and screw shafts separately offering wide range of combination. Ergonomic tool design offers safer and shorter operation time. ADVANTAGES: Moduler cups and screw shafts for various combinations Pratical and safe design Easy screw application Double flattened rod for derotation effect Eeasy transverse connector application Easy rod application with practical rod suppressor Practical and safe set screw design and application Low profile screw design Safer for screw pull out Ergonomic and anatomic tool design Failed fusion CONTRAINDICATIONS: Morbid obesity Severe psychiatric diseases Alcoholism and drug addiction Pregnancy Metal sensetivity / allergies Severe osteoporosis INDICATIONS: Posterior stabilization of thoracic and lumbar spine pathologies: Trauma Deformities: scoliosis,kyphosis, Degenerative spine diseases Spondylolisthesis Spinal stenosis Tumor Pseudoarthrosis

12 Specifications ORTOVIA Hyperflex Spinal System to to to to to Hyperflex Poliaxial Pedicular Screw Ø5.0mm x 30 to 45mm Hyperflex Poliaxial Pedicular Screw Ø5.5mm x 30 to 45mm Hyperflex Poliaxial Pedicular Screw Ø6.0mm x 30 to 60mm Hyperflex Poliaxial Pedicular Screw Ø6.5mm x 35 to 60mm Hyperflex Poliaxial Pedicular Screw Ø7.0mm x 35 to 65mm to to to to to Hyperflex Monoaxial Pedicular Screw Ø5.0mm x 30 to 45mm Hyperflex Monoaxial Pedicular Screw Ø5.5mm x 30 to 45mm Hyperflex Monoaxial Pedicular Screw Ø6.0mm x 30 to 60mm Hyperflex Monoaxial Pedicular Screw Ø6.5mm x 35 to 60mm Hyperflex Monoaxial Pedicular Screw Ø7.0mm x 35 to 65mm to to to to Hyperflex Poliaxial Pedicular Canulated Ø5.5 x 30 to 55mm Hyperflex Poliaxial Pedicular Canulated Ø6.0 x 30 to 60mm Hyperflex Poliaxial Pedicular Canulated Ø6.5 x 35 to 60mm Hyperflex Poliaxial Pedicular Canulated Ø7.0 x 35 to 65mm to to to to Hyperflex Monoaxial Pedicular Canulated Ø5.5 x 30 to 55mm Hyperflex Monoaxial Pedicular Canulated Ø6.0 x 30 to 60mm Hyperflex Monoaxial Pedicular Canulated Ø6.5 x 35 to 60mm Hyperflex Monoaxial Pedicular Canulated Ø7.0 x 35 to 65mm to to to to to Hyperflex Poliaxial Redüksiyon Pedicular Screw Ø5.0mm x 30 to 45mm Hyperflex Poliaxial Redüksiyon Pedicular Screw Ø5.5mm x 30 to 45mm Hyperflex Poliaxial Redüksiyon Pedicular Screw Ø6.0mm x 30 to 60mm Hyperflex Poliaxial Redüksiyon Pedicular Screw Ø6.5mm x 35 to 60mm Hyperflex Poliaxial Redüksiyon Pedicular Screw Ø7.0mm x 35 to 65mm to to to to to Hyperflex Monoaxial Redüksiyon Pedicular Screw Ø5.0mm x 30 to 45mm Hyperflex Monoaxial Redüksiyon Pedicular Screw Ø5.5mm x 30 to 45mm Hyperflex Monoaxial Redüksiyon Pedicular Screw Ø6.0mm x 30 to 60mm Hyperflex Monoaxial Redüksiyon Pedicular Screw Ø6.5mm x 35 to 60mm Hyperflex Monoaxial Redüksiyon Pedicular Screw Ø7.0mm x 35 to 65mm Headquarters: Metroport Busidence No :143, E5 Üzeri Kültür Sokak No: 1, Bahcelievler / Istanbul E- mail: info@spinamer.com R&D Department: Yildiz Technical University Davutpasa Campus, Technology Development Zone B2 Block, No: 14, Esenler / Istanbul research@spinamer.com Factory: Sanayi Mah Sok. No: Esenyurt / Istanbul Tel: Fax: factory@spinamer.com Supported by kosgeb R00 Design 2013 ahmed helmy Printed by Erkam Yayın San. Mam. ve Bilgisayar Ürün İm. Tic. A.Ş

13 Monopoly Spinal System Monopoly Practically Stable Modularity Polyaxial Screw Monopoly Screw Monopoly Reduction Cannulated Screw Polyaxial Reduction MONOPOLY SPINAL SYSTEM Adult set Pediatric set The system has modular design. Polyaxial, monoaxial and cannulated screws are represented as tulip head and screw shafts separately offering wide range of combination. Ergonomic tool design offers safer and shorter operation time. ADVANTAGES: Moduler cups and screw shafts for various combinations Pratical and safe design Easy screw application Double flattened rod for derotation effect Eeasy transverse connector application Easy rod application with practical rod suppressor Practical and safe set screw design and application Low profile screw design Safer for screw pull out Ergonomic and anatomic tool design The system is used for the following pathologies: Trauma Deformities: scoliosis,kyphosis, Degenerative disc disease Spondylolisthesis Spinal stenosis Tumor Pseudoarthrosis Failed fusion CONTRAINDICATIONS: Morbid obesity Severe psychiatric diseases Alcoholism and drug addiction Pregnancy Metal sensetivity / allergies Severe osteoporosis INDICATIONS: The spinal systems are used for posterior stabilization of thoracic and lumbar spine pathologies.

14 Specifications ORTOVIA Monopoly Spinal System to to to to to Monopoly Poliaxial Pedicular Screw Ø5.0mm x 30 to 45mm Monopoly Poliaxial Pedicular Screw Ø5.5mm x 30 to 45mm Monopoly Poliaxial Pedicular Screw Ø6.0mm x 30 to 60mm Monopoly Poliaxial Pedicular Screw Ø6.5mm x 35 to 60mm Monopoly Poliaxial Pedicular Screw Ø7.0mm x 35 to 65mm to to to to to Monopoly Monoaxial Pedicular Screw Ø5.0mm x 30 to 45mm Monopoly Monoaxial Pedicular Screw Ø5.5mm x 30 to 45mm Monopoly Monoaxial Pedicular Screw Ø6.0mm x 30 to 60mm Monopoly Monoaxial Pedicular Screw Ø6.5mm x 35 to 60mm Monopoly Monoaxial Pedicular Screw Ø7.0mm x 35 to 65mm to to to to Monopoly Poliaxial Pedicular Canulated Ø5.5 x 30 to 55mm Monopoly Poliaxial Pedicular Canulated Ø6.0 x 30 to 60mm Monopoly Poliaxial Pedicular Canulated Ø6.5 x 35 to 60mm Monopoly Poliaxial Pedicular Canulated Ø7.0 x 35 to 65mm to to to to Monopoly Monoaxial Pedicular Canulated Ø5.5 x 30 to 55mm Monopoly Monoaxial Pedicular Canulated Ø6.0 x 30 to 60mm Monopoly Monoaxial Pedicular Canulated Ø6.5 x 35 to 60mm Monopoly Monoaxial Pedicular Canulated Ø7.0 x 35 to 65mm to to to to to Monopoly Poliaxial Redüksiyon Pedicular Screw Ø5.0mm x 30 to 45mm Monopoly Poliaxial Redüksiyon Pedicular Screw Ø5.5mm x 30 to 45mm Monopoly Poliaxial Redüksiyon Pedicular Screw Ø6.0mm x 30 to 60mm Monopoly Poliaxial Redüksiyon Pedicular Screw Ø6.5mm x 35 to 60mm Monopoly Poliaxial Redüksiyon Pedicular Screw Ø7.0mm x 35 to 65mm to to to to to Monopoly Monoaxial Redüksiyon Pedicular Screw Ø5.0mm x 30 to 45mm Monopoly Monoaxial Redüksiyon Pedicular Screw Ø5.5mm x 30 to 45mm Monopoly Monoaxial Redüksiyon Pedicular Screw Ø6.0mm x 30 to 60mm Monopoly Monoaxial Redüksiyon Pedicular Screw Ø6.5mm x 35 to 60mm Monopoly Monoaxial Redüksiyon Pedicular Screw Ø7.0mm x 35 to 65mm Headquarters: Metroport Busidence No :143, E5 Üzeri Kültür Sokak No: 1, Bahcelievler / Istanbul E- mail: info@spinamer.com R&D Department: Yildiz Technical University Davutpasa Campus, Technology Development Zone B2 Block, No: 14, Esenler / Istanbul research@spinamer.com Factory: Sanayi Mah Sok. No: Esenyurt / Istanbul Tel: Fax: factory@spinamer.com Supported by kosgeb R00 Design 2013 ahmed helmy Printed by Erkam Yayın San. Mam. ve Bilgisayar Ürün İm. Tic. A.Ş

15 ACONDA Modular Hip Plate System excellent hip solutions Minimaly invasive Anotomic plate Locking Dynamic Cannulated lag screws T.major Fixation Low contact surface ACONDA MODULAR HIP PLATE SYSTEM Smallcut Plate Normalcut Plate Aconda is an anatomic and dynamic plate for fixation of proximal femur having five modules to fix proximal femur. The system has normalcutl and smallcut models having locking and dynamic models. The material is MRI friendly stainless steel. Indications Fractures of proximal femur Combined fractures of the proximal femur and ipsilateral shaft fractures Metastatic fracture of the proximal femur Osteotomies of the proximal femur Osteopenic bone Nonunions or malunions Contraindications İnfection of surgical region Severe osteoporosis and avascular necrosis Metal sensitivity Metastatic or malignant disasees of the surgical area Psychological conditions that the patient can not tolerate the postoperative care

16 Specifications to to to to Aconda Smallcut Dynamic Plate 6mm (S. Steel) (2 to 8 holes) Aconda Smallcut Locking Plate 6mm (S. Steel) (2 to 8 hole) Aconda Normalcut Locking Plate 6mm (S. Steel) (2 to 8 hole) Aconda Normalcut Dynamic Plate 6mm (S. Steel) (2 to 8 holes) to to Aconda Dynamic Compression Screw ø 6.5mm (S. Steel) (50 to 130mm) Aconda Cannulated Dynamic Comp. Screw ø 6.5mm (S. Steel) (50 to 130mm) Aconda Compression Threaded Sleeve ø 9.0 X 32mm (S. Steel) Aconda Compression Threaded Sleeve ø 9.0 X 25mm (S. Steel) to Aconda Major Screw ø 3.5mm (S. Steel) X 16mm to 60mm to to VS Cortical Screw ø 5.0mm (S. Steel) x 20mm to 70mm VS Cortical Locking Screw ø 5.0mm (S. Steel) x 20mm to 70mm Ortovia Cable ø 1.6mm ( S. Steel) Ortovia Cable ø 1.7mm ( S. Steel) Ortovia Cable ø 2.0mm (S. Steel) Headquarter & Sales: Metroport Busidence No :143, E5 Üzeri Kültür Sokak No: 1, Bahcelievler / Istanbul info@spinamer.com, sales@spinamer.com R&D Department: Yildiz Technical University Davutpasa Campus, Technology Development Zone B2 Block, No: 114, Esenler / Istanbul research@spinamer.com Factory: Sanayi Mah Sok. No: Esenyurt / Istanbul Tel: Fax: factory@spinamer.com Supported by kosgeb R00 Design 2013 ahmed helmy Printed by Erkam Yayın San. Mam. ve Bilgisayar Ürün İm. Tic. A.Ş

17 ORTOVIA Upper Extremity Smart Fixation Dorsal-side fixing radiolucent Joint telescopic Body Slyding clamp Easy lengthening MRI Compatability Fixat Types Wrist Forearm Humerus ORTOVIA Upper Extremity Fixator System is a series of modular monolateral external fixators for upper extremity that was developed under many years of clinical experience. The system is composed of wrist, forearm and humerus fixators. Features Modularity Easy application Short surgery time MRI compatability Flexibility-versatility Stability & safety in corrections Patient s comfort Radiolucent components Short learning curve Indications Bone loss Open fractures Comminuted fractures Non-union Angular deformities Limb reconstruction

18 Specifications Ortovia Slyding Clamp Small Ortovia Metaphysis Clamp Small Ortovia Polyclamp Small Ortovia Open Clamp Small Ortovia 3D Joint Small Ortovia Hinge Joint Small Ortovia Fixator Body LS10 Ortovia Fixator Body LS20 Ortovia Fixator Body LS25 Ortovia Wrist Fixator Short Ortovia Wrist Fixator Long Ortovia Shanz Screw 20mm Thread (S.Steel) Ø3X50MM Ortovia Shanz Screw 20mm Thread (S.Steel) Ø3X60MM Ortovia Shanz Screw 20mm Thread (S.Steel) Ø3X70MM Ortovia Shanz Screw 35mm Thread (S.Steel) Ø3X70MM Ortovia Shanz Screw 35mm Thread (S.Steel) Ø4X70MM Ortovia Shanz Screw 35mm Thread (S.Steel) Ø4X80MM Ortovia Shanz Screw 20mm Thread (Titanium) Ø3X50MM Ortovia Shanz Screw 20mm Thread (Titanium) Ø3X60MM Ortovia Shanz Screw 20mm Thread (Titanium) Ø3X70MM Ortovia Shanz Screw 35mm Thread (Titanium) Ø3X70MM Ortovia Shanz Screw 35mm Thread (Titanium) Ø4X70MM Ortovia Shanz Screw 35mm Thread (Titanium) Ø4X80MM Headquarter & Sales: Metroport Busidence No :143, E5 Üzeri Kültür Sokak No: 1, Bahcelievler / Istanbul info@spinamer.com, sales@spinamer.com R&D Department: Yildiz Technical University Davutpasa Campus, Technology Development Zone B2 Block, No: 114, Esenler / Istanbul research@spinamer.com Factory: Sanayi Mah Sok. No: Esenyurt / Istanbul Tel: Fax: factory@spinamer.com Supported by kosgeb R00 Design 2013 ahmed helmy Printed by Erkam Yayın San. Mam. ve Bilgisayar Ürün İm. Tic. A.Ş

19 Ortovia android External Lengthening System Software Control Remote Access Internet Connection Lengthening Shortening Precise Mechatronic Ortovia android Lengthening system designed to be used in lengthening and shortening purpose of the limb is a rigid and precision mechatronic external lengthening system. Ortovia app. is a spetial android-based software that authrized orthopedic surgeon can program and operate the system with remote access via the Internet. On this system Ortovia.app is installed in patient s mobile phone, the doctor by his mobile phone or PC can reach the relevant patient s lengthening system and obtain information about the current situation, and also he can reprogram the lengthening or shortening process. Indications: lengthening and shortening process in long bones Contraindications: In case the patient does not have enough psychological and intellectual abilities to sustain the operation and postoperative treatment. Other known contraindications of limb lengthening process.

20 Specifications Ortovia L30 android fixator Ortovia L25 android fixator Ortovia L20 android fixator Ortovia LS25 android fixator Ortovia LS20 android fixator Ortovia LR25 android fixator Ortovia LR20 android fixator Ortovia LRS20 android fixator ORTOVIA SLYDING CLAMP ORTOVIA SLYDING CLAMP 1/2 ORTOVIA METAPHYSIS CLAMP ORTOVIA POLYCLAMP Electronic Control Unit Ortovia app. Software Headquarter & Sales: Metroport Busidence No :143, E5 Üzeri Kültür Sokak No: 1, Bahcelievler / Istanbul info@spinamer.com, sales@spinamer.com R&D Department: Yildiz Technical University Davutpasa Campus, Technology Development Zone B2 Block, No: 114, Esenler / Istanbul research@spinamer.com Factory: Sanayi Mah Sok. No: Esenyurt / Istanbul Tel: Fax: factory@spinamer.com Supported by kosgeb R00 Design 2013 ahmed helmy Printed by Erkam Yayın San. Mam. ve Bilgisayar Ürün İm. Tic. A.Ş

Zimmer Small Fragment Universal Locking System. Surgical Technique

Zimmer Small Fragment Universal Locking System. Surgical Technique Zimmer Small Fragment Universal Locking System Surgical Technique Zimmer Small Fragment Universal Locking System 1 Zimmer Small Fragment Universal Locking System Surgical Technique Table of Contents Introduction

More information

PERIPROSTHETIC IMPLANTS

PERIPROSTHETIC IMPLANTS PERIPROSTHETIC IMPLANTS PRODUCT OVERVIEW CLINICAL SOLUTIONS Periprosthetic fractures present unique challenges, such as how to gain fixation when the medullary canal is occupied. Special techniques and

More information

Zimmer Periarticular Proximal Tibial Locking Plate

Zimmer Periarticular Proximal Tibial Locking Plate Zimmer Periarticular Proximal Tibial Locking Plate Surgical Technique The Science of the Landscape Zimmer Periarticular Proximal Tibial Locking Plate 1 Table of Contents Introduction 2 Locking Screw Technology

More information

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system. Technique Guide Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system. Table of Contents Introduction Large Fragment LCP Instrument and Implant Set

More information

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery. Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by

More information

NCB Distal Femur System. Surgical Technique

NCB Distal Femur System. Surgical Technique NCB Distal Femur System Surgical Technique NCB Distal Femur System Surgical Technique 3 Surgical Technique NCB Distal Femur System Table of Contents Introduction 4 Indications 8 Preoperative Planning

More information

Degenerative Spine Solutions

Degenerative Spine Solutions Degenerative Spine Solutions The Backbone for Your Surgical Needs Aesculap Spine Backbone for Your Degenerative Spine Needs Comprehensive operative solutions, unique product technology and world-class

More information

The information contained in this document is intended for healthcare professionals only.

The information contained in this document is intended for healthcare professionals only. The information contained in this document is intended for healthcare professionals only. Dall-Miles Cabling System Dall-Miles Recon and Trauma Cable System Trochanteric Reattachment Using the Trochanteric

More information

How To Use A Phoenix Retrograde Femoral Nail

How To Use A Phoenix Retrograde Femoral Nail Phoenix Retrograde Femoral Nail System Featuring CoreLock Technology Surgical Technique Contents Introduction... Page 1 Indications... Page 2 Design Features... Page 3 Surgical Technique... Page 6 Product

More information

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis. Technique Guide 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis. Table of Contents Introduction 3.5 mm and 4.5 mm Curved Locking Compression 2 Plates (LCP)

More information

DARCO MRS. Locked Plating System for Reconstructive Rearfoot Surgery

DARCO MRS. Locked Plating System for Reconstructive Rearfoot Surgery DARCO MRS Locked Plating System for Reconstructive Rearfoot Surgery DARCO MRS Locked plating system for reconstructive rearfoot surgery System Basics The DARCO MRS plating system for the rearfoot has been

More information

Lentur Cable System. Surgical Technique

Lentur Cable System. Surgical Technique Lentur Cable System Surgical Technique Contents Introduction... Page 1 System Design Features And Benefits... Page 2 Implants... Page 3 Instrumentation... Page 4 Surgical Technique... Page 5 Single Cable...

More information

NCB Periprosthetic Femur Plate System. Surgical Technique

NCB Periprosthetic Femur Plate System. Surgical Technique NCB Periprosthetic Femur Plate System Surgical Technique NCB Periprosthetic Femur System Surgical Technique 3 Table of Contents Introduction 4 System Features and Benefits 9 Indications and Contraindications

More information

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery. Technique Guide Orthopaedic Cable System. Cerclage solutions for general surgery. Table of Contents Introduction The Orthopaedic Cable System 2 Indications 4 Contraindications 4 Surgical Technique Cerclage

More information

Zimmer Periarticular Elbow Locking Plate System

Zimmer Periarticular Elbow Locking Plate System Zimmer Periarticular Elbow Locking Plate System Surgical Technique The Right Solutions for Fractures Around the Elbow Disclaimer This document is intended exclusively for physicians and is not intended

More information

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Wrist and Hand Fractures of the Wrist and Hand: Fractures of the wrist The wrist joint is made up of the two bones in your

More information

Information for the Patient About Surgical

Information for the Patient About Surgical Information for the Patient About Surgical Decompression and Stabilization of the Spine Aging and the Spine Daily wear and tear, along with disc degeneration due to aging and injury, are common causes

More information

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue. Surgical technique End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue. Table of contents Indications and contraindications 3 Implants 4 Instruments 4 Preoperative planning

More information

How To Fix A Radial Head Plate

How To Fix A Radial Head Plate Mayo Clinic CoNGRUENT RADIAL HEAD PLATE Since 1988 Acumed has been designing solutions to the demanding situations facing orthopedic surgeons, hospitals and their patients. Our strategy has been to know

More information

Fracture Fixation Devices Compression Hip Screws Cannulated/Bone Screws Bone Plates, Pins, Wires

Fracture Fixation Devices Compression Hip Screws Cannulated/Bone Screws Bone Plates, Pins, Wires Fracture Fixation Devices Compression Hip Screws Cannulated/Bone Screws Bone Plates, Pins, Wires IMPORTANT MEDICAL INFORMATION EN SPECIAL NOTE Fracture fixation devices are used only as an aid to healing;

More information

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE SALVATION Fusion Bolts and Beams SURGICAL TECHNIQUE Contents Chapter 1 4 Introduction Chapter 2 4 Intended Use Chapter 3 4 Device Description 4 Fusion Beams 5 Fusion Bolts Chapter 4 5 Preoperative Planning

More information

Cable System. For Orthopaedic Trauma Surgery.

Cable System. For Orthopaedic Trauma Surgery. Cable System. For Orthopaedic Trauma Surgery. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Image intensifier

More information

TransFx External Fixation System Large and Intermediate Surgical Technique

TransFx External Fixation System Large and Intermediate Surgical Technique TransFx External Fixation System Large and Intermediate Surgical Technique TransFx External Fixation System Large and Intermediate Surgical Technique 1 Surgical Technique For TransFx External Fixation

More information

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System. Technique Guide 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System. Table of Contents Introduction 4.5 mm LCP Proximal Femur Plates 2 AO Principles 4 Indications 5 Surgical

More information

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique Surgical Technique TABLE OF CONTENTS Slimplicity Anterior Cervical Plate System Overview 2 Indications 2 Implants 3 Instruments 4 Surgical Technique 6 1. Patient Positioning and Approach 6 2. Plate Selection

More information

Rodding Surgery. 804 W. Diamond Ave., Ste. 210 Gaithersburg, MD 20878 (800) 981-2663 (301) 947-0083

Rodding Surgery. 804 W. Diamond Ave., Ste. 210 Gaithersburg, MD 20878 (800) 981-2663 (301) 947-0083 Rodding Surgery 804 W. Diamond Ave., Ste. 210 Gaithersburg, MD 20878 (800) 981-2663 (301) 947-0083 Fax: (301) 947-0456 Internet: www.oif.org Email: bonelink@oif.org The Osteogenesis Imperfecta Foundation,

More information

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD Zimmer Natural Nail System Cephalomedullary Nail Surgical Technique STANDARD Zimmer Natural Nail System Cephalomedullary Nail Surgical Technique - Standard 1 Zimmer Natural Nail System Cephalomedullary

More information

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information 5. 1. Patient Positioning and Approach 2

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information 5. 1. Patient Positioning and Approach 2 Surgical Technique TABLE OF CONTENTS Surgical Technique 2 1. Patient Positioning and Approach 2 2. Intervertebral Device Implanted 2 3. Buttress Plate Selection 2 4. Awl Insertion 2 5. Screw Insertion

More information

CLAW II. Polyaxial Compression Plating System SURGIC A L T ECHNIQUE

CLAW II. Polyaxial Compression Plating System SURGIC A L T ECHNIQUE CLAW II Polyaxial Compression Plating System SURGIC A L T ECHNIQUE Contents Chapter 1 2 3 3 3 Chapter 2 4 4 7 Chapter 3 8 8 8 8 8 8 8 9 11 11 11 Chapter 4 12 Introduction Intended Use Indications Contraindications

More information

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation. Technique Guide DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation. Table of Contents Introduction Dynamic Hip Screw (DHS) 2 Dynamic Condylar Screw (DCS) 3 Indications

More information

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures. Technique Guide Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures. Table of Contents Introduction Titanium Trochanteric Fixation Nail System 2 Biomechanical

More information

.org. Fractures of the Thoracic and Lumbar Spine. Cause. Description

.org. Fractures of the Thoracic and Lumbar Spine. Cause. Description Fractures of the Thoracic and Lumbar Spine Page ( 1 ) Spinal fractures can vary widely in severity. While some fractures are very serious injuries that require emergency treatment, other fractures can

More information

BONE PRESERVATION STEM

BONE PRESERVATION STEM TRI-LOCK BONE PRESERVATION STEM Featuring GRIPTION Technology SURGICAL TECHNIQUE IMPLANT GEOMETRY Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was

More information

ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine

ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine Anterior In the human anatomy, referring to the front surface of the body or position of one structure relative to another Cervical Relating to the neck, in the spine relating to the first seven vertebrae

More information

V-TEK IVP System 2.7 System 4.0

V-TEK IVP System 2.7 System 4.0 V-TEK IVP System Ankle 2.7 Fix System 4.0 Surgical Technique Surgical Technique Titanium osteosynthesis system for tibio-talar and tibio-talo-calcaneal fusion SECTION 1 Ankle Fix System 4.0 Titanium osteosynthesis

More information

OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique

OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique OptiLock Periarticular Plating System For Proximal Tibial Fractures Pre-Launch Surgical Technique Contents Introduction... Page 1 Indications & Fracture Classifications... Page 4 Design Features... Page

More information

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates VariAx Distal Radius Plate System Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates System Module The NEW VariAx Distal Radius Plating System represents the Next Generation of

More information

Patient Guide to Lower Back Surgery

Patient Guide to Lower Back Surgery The following is a sampling of products offered by Zimmer Spine for use in Open Lumbar Fusion procedures. Patient Guide to Lower Back Surgery Open Lumbar Fusion Dynesys The Dynesys Dynamic Stabilization

More information

Implant Extraction Guide Module One & Two

Implant Extraction Guide Module One & Two Implant Extraction Set Implant Extraction Guide Module One & Two 1 Contents Page 1. Introduction 3 Introduction 3 Features and Benefits 3 Contraindications 3 2. Product Description 4 3. Technical Details

More information

GENEL KATALOG GENERAL CATALOGUE KİLİTSİZ PLAKLAR NON LOCKING PLATES

GENEL KATALOG GENERAL CATALOGUE KİLİTSİZ PLAKLAR NON LOCKING PLATES KİLİTSİZ PLAKLAR NON LOCKING PLATES 33 34 35 36 37 38 39 40 41 42 43 44 45 46 Ulnar Olecranon Plate Ti DELİK KAT.NO. HOLE CAT.NO. 3 A22014030 4 A22014040 5 A22014050 6 A22014060 7 A22014070 8 A22014080

More information

September 25, 2014. Dear Ms. McCoy:

September 25, 2014. Dear Ms. McCoy: DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center WO66-G609 Silver Spring, MD 20993-0002 September 25, 2014 Biomet

More information

TABLE OF CONTENTS. Indications and Contraindications 3. Features and Benefits 4. Ease of connection 4 Stable fixation concept 5

TABLE OF CONTENTS. Indications and Contraindications 3. Features and Benefits 4. Ease of connection 4 Stable fixation concept 5 Surgical Technique TABLE OF CONTENTS Indications and Contraindications 3 Features and Benefits 4 Ease of connection 4 Stable fixation concept 5 Surgical Technique Steps 6 Identification and preparation

More information

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL) Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL) Mark Glazebrook James Stone Masato Takao Stephane Guillo Introduction Ankle stabilization is required when a patient

More information

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW MINI FRAGMENT SYSTEM Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW TABLE OF CONTENTS INTRODUCTION Mini Fragment System 2 PRODUCT INFORMATION Plates 4 Screws 6

More information

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion Surgical Technique Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion Prepared in consultation with: Phinit Phisitkul, MD Department of Orthopedics and Rehabilitation University of Iowa

More information

Minimally Invasive Spine Surgery For Your Patients

Minimally Invasive Spine Surgery For Your Patients Minimally Invasive Spine Surgery For Your Patients Lukas P. Zebala, M.D. Assistant Professor Orthopaedic and Neurological Spine Surgery Department of Orthopaedic Surgery Washington University School of

More information

TriLock 1.5 Implants for the Phalanges

TriLock 1.5 Implants for the Phalanges P R O D U C T IN F O RM AT I O N TriLock 1.5 Implants for the Phalanges APTUS Hand 2 TriLock 1.5 Implants for the Phalanges TriLock 1.5 The Smallest Locking System Small, slender, strong Low profile and

More information

Polaris Deformity System Trivium Derotation System

Polaris Deformity System Trivium Derotation System Polaris Deformity System Trivium Derotation System A Three Dimensional Approach to Deformity Correction The Polaris Deformity System in combination with the Trivium Derotation System incorporates Enbloc

More information

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y Y O U R S U R G E O N S choice of implants F O R Y O U R S U R G E R Y Y O U R S U R G E O N S choice of implants F O R Y O U R S U R G E R Y Your Surgeon Has Chosen the C 2 a-taper Acetabular System The

More information

Adult Forearm Fractures

Adult Forearm Fractures Adult Forearm Fractures Your forearm is made up of two bones, the radius and ulna. In most cases of adult forearm fractures, both bones are broken. Fractures of the forearm can occur near the wrist at

More information

Advances In Spine Care. James D. Bruffey M.D. Scripps Clinic Division of Orthopaedic Surgery Section of Spinal Surgery

Advances In Spine Care. James D. Bruffey M.D. Scripps Clinic Division of Orthopaedic Surgery Section of Spinal Surgery Advances In Spine Care James D. Bruffey M.D. Scripps Clinic Division of Orthopaedic Surgery Section of Spinal Surgery Introduction The Spine - A common source of problems Back pain is the #2 presenting

More information

Technique Guide. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system.

Technique Guide. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system. Technique Guide 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system. Table of Contents Introduction 2.7 mm/3.5 mm Variable

More information

LCP Compact Foot/Compact Hand.

LCP Compact Foot/Compact Hand. LCP Compact Foot/Compact Hand. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Table of contents Indications 2

More information

MEDACTA UNCONSTRAINED SCREW TECHNOLOGY. Surgical Technique. Hip Knee Spine Navigation

MEDACTA UNCONSTRAINED SCREW TECHNOLOGY. Surgical Technique. Hip Knee Spine Navigation .U.S.T. MEDACTA UNCONSTRAINED SCREW TECHNOLOGY Hip Knee Spine Navigation M.U.S.T. Hip Knee Spine Navigation CAUTION Federal law (USA) restricts this device to sale distrribution and use by or on the order

More information

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws. Technique Guide Screw Removal Set. Instruments for removing Synthes screws. Table of Contents Introduction Screw Removal Set 2 Surgical Technique Preoperative Planning and Preparation 6 Removal of Intact

More information

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE FUSEFORCE Hand Fixation System SURGIC A L T ECHNIQUE Contents Chapter 1 3 Chapter 2 4 Appendix A 7 Intended Use Surgical Technique Ordering Information Indication Sizing Reference Proper surgical procedures

More information

DUKE ORTHOPAEDIC SURGERY GOALS AND OBJECTIVES SPINE SERVICE

DUKE ORTHOPAEDIC SURGERY GOALS AND OBJECTIVES SPINE SERVICE GOALS AND OBJECTIVES PATIENT CARE Able to perform a complete musculoskeletal and neurologic examination on the patient including cervical spine, thoracic spine, and lumbar spine. The neurologic examination

More information

Titanium Wire with Barb and Needle. For canthal tendon procedures.

Titanium Wire with Barb and Needle. For canthal tendon procedures. Titanium Wire with Barb and Needle. For canthal tendon procedures. Technique Guide Instruments and implants approved by the AO Foundation Table of Contents Introduction Titanium Wire with Barb and Needle

More information

Minimally Invasive Spine Surgery What is it and how will it benefit patients?

Minimally Invasive Spine Surgery What is it and how will it benefit patients? Minimally Invasive Spine Surgery What is it and how will it benefit patients? Dr Raoul Pope MBChB, FRACS, Neurosurgeon and Minimally Invasive Spine Surgeon Concord Hospital and Mater Private Hospital Sydney

More information

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach. Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach. Technique Guide Instruments and implants approved by the AO Foundation

More information

TwinFix Cannulated Compression Screw

TwinFix Cannulated Compression Screw TwinFix Cannulated Compression Screw Leibinger Solutions for Hand Surgery Procedural Guide TwinFix Sterilization, Organization, Storage 29-12020 Profyle MODULAR Sterilizing Container 29-40162 TwinFix Implant

More information

NCB Proximal Humerus System. Surgical Technique

NCB Proximal Humerus System. Surgical Technique NCB Proximal Humerus System Surgical Technique NCB Proximal Humerus System Surgical Technique 3 Surgical Technique NCB Proximal Humerus System Table of Contents Introduction 4 Cable Fixation Options 5

More information

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail Aesculap Veterinary Orthopaedics Targon VET Interlocking Nail Flexibility Stability Dynamics The Targon VET is based on new, technology which reverses the known principles of interlocking nails. The rotation-stabilising

More information

Patient Guide to Neck Surgery

Patient Guide to Neck Surgery The following is a sampling of products offered by Zimmer Spine for use in Anterior Cervical Fusion procedures. Patient Guide to Neck Surgery Anterior Cervical Fusion Trinica Select With the Trinica and

More information

Expert LFN. Lateral Femoral Nail.

Expert LFN. Lateral Femoral Nail. Expert LFN. Lateral Femoral Nail. Surgical Technique EXPERT Nailing System This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Image intensifier

More information

Technique Guide. 2.4 mm LCP Distal Radius System. A comprehensive plating system to address a variety of fracture patterns.

Technique Guide. 2.4 mm LCP Distal Radius System. A comprehensive plating system to address a variety of fracture patterns. Technique Guide 2.4 mm LCP Distal Radius System. A comprehensive plating system to address a variety of fracture patterns. Table of Contents Introduction 2.4 mm LCP Distal Radius System 2 AO Principles

More information

Achilles Tendon Repair, Operative Technique

Achilles Tendon Repair, Operative Technique *smith&nephew ANKLE TECHNIQUE GUIDE Achilles Tendon Repair, Operative Technique Prepared in Consultation with: C. Niek van Dijk, MD, PhD KNEE HIP SHOULDER EXTREMITIES Achilles Tendon Repair, Operative

More information

SPINAL STENOSIS Information for Patients WHAT IS SPINAL STENOSIS?

SPINAL STENOSIS Information for Patients WHAT IS SPINAL STENOSIS? SPINAL STENOSIS Information for Patients WHAT IS SPINAL STENOSIS? The spinal canal is best imagined as a bony tube through which nerve fibres pass. The tube is interrupted between each pair of adjacent

More information

visualized. The correct level is then identified again. With the use of a microscope and

visualized. The correct level is then identified again. With the use of a microscope and SURGERY FOR SPINAL STENOSIS Laminectomy A one inch (or longer for extensive stenosis) incision is made in the middle of the back over the effected region of the spine. The muscles over the bone are moved

More information

Malleolar fractures Anna Ekman, Lena Brauer

Malleolar fractures Anna Ekman, Lena Brauer Malleolar fractures Anna Ekman, Lena Brauer How to use this handout? The left column is the information as given during the lecture. The column at the right gives you space to make personal notes. Learning

More information

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials Implant materials How to use this handout? The left column is the information as given during the lecture. The column at the right gives you space to make personal notes. Learning outcomes At the end of

More information

Minimally Invasive Spine Surgery

Minimally Invasive Spine Surgery Chapter 1 Minimally Invasive Spine Surgery 1 H.M. Mayer Primum non nocere First do no harm In the long history of surgery it always has been a basic principle to restrict the iatrogenic trauma done to

More information

Minimally Invasive Lumbar Fusion

Minimally Invasive Lumbar Fusion Minimally Invasive Lumbar Fusion Biomechanical Evaluation (1) coflex-f screw Biomechanical Evaluation (1) coflex-f intact Primary Stability intact Primary Stability Extension Neutral Position Flexion Coflex

More information

coligne treatment technology

coligne treatment technology coligne treatment technology coligne a strategy in spine Leadership begins before the patient enters the surgical theater, among the spine care professionals forming the coalliance. This may be a small

More information

Ankle Syndesmosis Surgical Protocol by Timothy Charlton, M.D.

Ankle Syndesmosis Surgical Protocol by Timothy Charlton, M.D. Featuring Ankle Syndesmosis Surgical Protocol by Timothy Charlton, M.D. ZipLoop Technology is a unique weave in which a single strand of braided polyethylene is woven through itself twice in opposite directions.

More information

Jonathan R. Gottlieb, MD 7220 SW 127 Street Pinecrest, FL 33156 jonrgottlieb@gmail.com

Jonathan R. Gottlieb, MD 7220 SW 127 Street Pinecrest, FL 33156 jonrgottlieb@gmail.com Jonathan R. Gottlieb, MD 7220 SW 127 Street Pinecrest, FL 33156 jonrgottlieb@gmail.com CURRENT PRACTICE September 2009-present University of Miami School of Medicine Assistant Professor, Department of

More information

ACCORD Cable System. Surgical technique completed in conjunction with: Robert Barrack, MD St. Louis, Missouri. Paul Di Cesare, MD New York, New York

ACCORD Cable System. Surgical technique completed in conjunction with: Robert Barrack, MD St. Louis, Missouri. Paul Di Cesare, MD New York, New York Surgical Technique Innovations in Hip Surgery 2 ACCORD Cable System Surgical technique completed in conjunction with: Robert Barrack, MD St. Louis, Missouri Paul Di Cesare, MD New York, New York Fares

More information

Elbow System 2.0, 2.8

Elbow System 2.0, 2.8 SurgicAL TecHNiqUE STEP by step Elbow System 2.0, 2.8 APTUS Elbow 2 Elbow System 2.0, 2.8 Elbow System 2.0, 2.8 3 Elbow System 2.0, 2.8 Contents 4-5 Features, Technique 6-13 Introduction and Indications

More information

Scaphoid Fracture of the Wrist

Scaphoid Fracture of the Wrist Page 1 of 6 Scaphoid Fracture of the Wrist Doctors commonly diagnose a sprained wrist after a patient falls on an outstretched hand. However, if pain and swelling don't go away, doctors become suspicious

More information

ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA INNOVATION MEANS MOTION

ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA INNOVATION MEANS MOTION ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA POLYAXIAL LOCKING FIXATION DUALTEC SYSTEM II Precontoured implants Polyaxiality of 20 2 surgical approaches : lateral and posterolateral ACTIV ANKLE The ACTIV ANKLE

More information

The goals of modern spinal surgery are to maximize

The goals of modern spinal surgery are to maximize SPRING 2013 Robot-Guided Spine Surgery Christopher R. Good, M.D., F.A.C.S. and Blair K. Snyder, P.A.-C. The goals of modern spinal surgery are to maximize patient function and accelerate a return to a

More information

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

INTRODUCTION Cerclage Cable Vs. Monofilament Wire B M P CABLE S Y S T E M S U R G I C A L TECHNIQUE INTRODUCTION The Biomet Medical Products (BMP ) Cable System provides a cost effective and simple method of trochanteric reattachment, fracture fixation,

More information

Proximal Hip Fracture Open Reduction/Internal Fixation and Rehabilitation

Proximal Hip Fracture Open Reduction/Internal Fixation and Rehabilitation 1 Proximal Hip Fracture Open Reduction/Internal Fixation and Rehabilitation Surgical indications and Considerations Anatomical Considerations: The hip is a ball and socket joint with the femoral head aligned

More information

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair. Multiple closure options Stable fixation in all configurations Improved strength and flexibility compared to wire Modular

More information

Universal Screw Removal System (USR)

Universal Screw Removal System (USR) Craniomaxillofacial Surgery 3 Universal Screw Removal System (USR) Craniomaxillofacial rigid fixation systems are available from a variety of manufacturers. The USR system is a complete screwdriver array

More information

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1 DRAFT Version 1 Triathlon TS Knee System Table of Contents Acknowledgments..........................................................2 Tibial Canal Preparation....................................................4

More information

TFN Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

TFN Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures. TFN Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures. Surgical Technique This publication is not intended for distribution in the USA. Instruments and

More information

LCP Olecranon Plate. The anatomical fixation system with angular stability for olecranon and proximal ulnar fractures.

LCP Olecranon Plate. The anatomical fixation system with angular stability for olecranon and proximal ulnar fractures. LCP Olecranon Plate. The anatomical fixation system with angular stability for olecranon and proximal ulnar fractures. Surgical Technique This publication is not intended for distribution in the USA. Instruments

More information

Spinal Arthrodesis Group Exercises

Spinal Arthrodesis Group Exercises Spinal Arthrodesis Group Exercises 1. Two surgeons work together to perform an arthrodesis. Dr. Bonet, a general surgeon, makes the anterior incision to gain access to the spine for the arthrodesis procedure.

More information

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Surgical Technique This publication is not intended for distribution

More information

TRIGEN INTERTAN Intertrochanteric Antegrade Nail Surgical Technique. Table of Contents

TRIGEN INTERTAN Intertrochanteric Antegrade Nail Surgical Technique. Table of Contents Surgical Technique TRIGEN INTERTAN Intertrochanteric Antegrade Nail Surgical Technique As described by: Andreas H. Ruecker, MD Thomas A. Russell, MD Roy W. Sanders, MD Paul Tornetta, MD Table of Contents

More information

Expert TN. Tibial Nail.

Expert TN. Tibial Nail. Expert TN. Tibial Nail. Surgical Technique Expert Nailing System This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Image intensifier

More information

Distal Radius Fractures. Lee W Hash, MD Affinity Orthopedics and Sports Medicine

Distal Radius Fractures. Lee W Hash, MD Affinity Orthopedics and Sports Medicine Distal Radius Fractures Lee W Hash, MD Affinity Orthopedics and Sports Medicine The Problem of Distal Radius Fractures Common injury: >450,000/yr. in USA High potential for functional impairment and frequent

More information

TRIGEN TAN and FAN Intramedullary Nails

TRIGEN TAN and FAN Intramedullary Nails Surgical Technique TRIGEN TAN and FAN Intramedullary Nails Surgical Technique Table of Contents Indications...2 TRIGEN TAN and FAN Case Examples...3 Design Features: TAN...4 Implant Specifications: TAN...5

More information

Fracture Care Coding September 28, 2011

Fracture Care Coding September 28, 2011 Fracture Care Coding September 28, 2011 Julie Edens Leu, CPC, CPCO, CPMA, CPC-I 1 Disclaimer Every reasonable effort has been made to ensure that the educational material provided today is accurate and

More information

Calcaneus (Heel Bone) Fractures

Calcaneus (Heel Bone) Fractures Copyright 2010 American Academy of Orthopaedic Surgeons Calcaneus (Heel Bone) Fractures Fractures of the heel bone, or calcaneus, can be disabling injuries. They most often occur during high-energy collisions

More information

Does the pain radiating down your legs, buttocks or lower back prevent you from walking long distances?

Does the pain radiating down your legs, buttocks or lower back prevent you from walking long distances? Does the pain radiating down your legs, buttocks or lower back prevent you from walking long distances? Do you experience weakness, tingling, numbness, stiffness, or cramping in your legs, buttocks or

More information

Case Report Reconstructive Osteotomy for Ankle Malunion Improves Patient Satisfaction and Function

Case Report Reconstructive Osteotomy for Ankle Malunion Improves Patient Satisfaction and Function Case Reports in Orthopedics Volume 2015, Article ID 549109, 5 pages http://dx.doi.org/10.1155/2015/549109 Case Report Reconstructive Osteotomy for Ankle Malunion Improves Patient Satisfaction and Function

More information

Magnetic Resonance Imaging

Magnetic Resonance Imaging Magnetic Resonance Imaging North American Spine Society Public Education Series What Is Magnetic Resonance Imaging (MRI)? Magnetic resonance imaging (MRI) is a valuable diagnostic study that has been used

More information

Zimmer MOST Options System

Zimmer MOST Options System Zimmer MOST Options System Surgical Technique Modular Options for Severe Bone Loss and Trauma Zimmer MOST Options System Surgical Technique 1 MOST Options System Surgical Technique Table of Contents Introduction

More information