Triol АТ24. Low-voltage variable frequency drives.

Size: px
Start display at page:

Download "Triol АТ24. Low-voltage variable frequency drives."

Transcription

1 Triol АТ24 Low-voltage variable frequency drives Catalogue

2

3 Triol АТ24 Low voltage variable frequency drive Contents Introduction... Review of lines... Line 1... Line 2... Line 3... Line 4... Line C... Line E... Line Н (380 V)... Line Н (660 V)... Line К... Line 5... Line 7... Line 9... Line А... Line М... Support documentation review... Additional equipment... Services... Intro RL C E Н/380 V Н/660 V K A М SD AE S 1

4 Introduction Dear customers! Intro This catalogue presents low voltage variable frequency drive Triol AT24. For your convenience the document is divided into several sections that contain information about separate product lines. Whole Triol AT24 product range is shown in the table, containing the products described in the catalogue (lines for lifts (elevators), pumps, cranes, HVAC, multidrive and industrial application). All information about each line is presented in such sections: application, Key functions and features, mechanical and protection parameters, technical characteristics, connection diagram, overall dimensions and VFD configurations. Variable speed drives Triol AT24 are successfully operating in a wide range of areas: fuel and energy sector, housing and utilities infrastructure, mining industry, construction industry, cement production and metallurgy. We are constantly analyzing our performance results and looking for opportunities to improve our products. We invite everybody to consolidate our efforts to achieve together outstanding results. We appreciate our Partners and Customers and are always open for cooperation! 2

5 Review of lines АТ24-ХХХ-ХХХ-ХХХХХХ Variable frequency drive (VFD) series name АТ24 Low voltage variable frequency drive. RL 2 VFD power in accordance with power range For instance, 5K5 5,5 kw; 90K 90 kw, M kw or 0,25 MW. 3 Rated input voltage 380 V 660 V 4 Triol АТ24 line type In accordance with the line types descriptions following below. 5 Built-in power units 0 Without built-in blocks, 1 Built-in choke, 2 Brake module, 3 EMI filter, 4 Sinewave filter. 6 Input-output modules 0 Without built-in input-output modules, 1 Extension board Module EXT1; 2 Extension board Module EXT2 Termo; 3 Extension board Module EXT3 Relay; 4 Reserve; А Multipump (used for a simultaneous control of several pumps). 7 Interface module 0 Without built-in interface modules, 1 Reserve, 2 Module Anet_CAN (CanOpen), 3 Module Anet_Profibus (Profibus DP), 4 Module Anet_LAN (Ethernet IP) 5 Module Anet2_RS485 (Modbus RTU, 2 link channels are available). 8 Encoder module 0 Without built-in units, 1 Incremental encoder module ENCO2, 2 Absolute encoder module ENCO3. 9 Lodgement (locating block) module 0 Without built-in units; 1 Wi-Fi adapter; 2 USB-host adapter; 3 USB-device adapter. 3

6 RL Line type Application Power range Supply voltage Enclosure Line 1 Lift (Elevator) 5.5 kw kw 380 V plastic, IP20 Line 2 HVAC 5,5 kw kw 380 V plastic, IP20 Line 3 HVAC 75 kw kw 380 V metal, IP20 Line 4 HVAC 370 W... 4 kw 380 V plastic, IP20 Line 5 Industrial 5,5 kw kw 380 V metal, IP54 Line 7 Industrial 5,5 kw kw 380 V metal, IP54 Line 9 Industrial 5,5 kw kw 380 V metal, IP54 Line А Lift (Elevator) 5,5 kw kw 380 V metal, IP54 Line B HVAC 5,5 kw kw 380 V metal, IP54 Line С Pump 5,5 kw kw 380 V plastic, IP20 Line Е Pump 75 kw kw 380 V metal, IP20 Line H Pump 5,5 kw kw 380 V metal, IP54 Line H Pump 75 kw kw 660 V metal, IP54 Line K Crane 5,5 kw kw 380 V metal, IP54 Line М Multidrive 5,5 kw... 2 MW 380 V metal, IP20 4

7 Line 1 1 Application Triol AT24 VFD Line 1 is an optimized solution for every elevator. This line is specially designed to provide safety and reliability of the lift mechanisms operation. The equipment features are state-of-the-art technical solutions and functionality suitable for the most critical applications. Key functions start, stop and control of motor rotation frequency; acceleration and deceleration ramps including S-shaped ramps; reversal; acceleration, decreasing, stop; protection of the motor overcurrent, overload protection lift operation at fixed speeds, capability of universal setting to the lift VSD (variable speed drives) and integration with lift control systems used for an old housing stock; saving control configuration of motor; dynamic braking of motor; operation mode «Evacuation»; operation mode «Short floor»; operation mode «Inspection»; braking unit control support; motor contactor control; vector control with and without speed feedback. 1.1

8 Protection functions 1 protection against overheating of power modules; motor protection against overheating using motor temperature sensor; overvoltage and under voltage protection in DC-link of VFD; short-circuit at VFD output protection; protection against increasing currents at VFD output; desaturation protection; input single-phasing protection; «Emergency stop» command from emergency stop circuit. Mechanical parameters plastic enclosure, IP20; forced cooling (fans, air flow direction from the bottom upwards); operation temperature -20 C C; simple connection of input and output cables ; convenient demountable control panel with graphic display; possibility of VFD installation in small-size cabinets or in confined space; resistance to continuous sinewave vibration 0.5 G in three planes. 1.2

9 Line 1 Power cables connection diagram (АТ24-5К5...7К5) L1 L2 L3 PE Line-disconnection 1 Grounding plate Built-in EMC filter of Class C2 +Rb and Rb terminals are used only for connecting brake resistor -DC and +Rb terminals are used for connecting regeneration unit +Ld and +Ud terminals are used for connecting the DC-link external choke * +Rb -Rb -DC +Ld +Ud R/L1 S/L2 T/L3 АС AT24-5K5 7K ***** variable-frequency drive DC DC АС U/T1 V/T2 W/T3 du/dt filter * For variable-frequency drives w/o any built-in chokes in DC-link М 1.3

10 1 Technical characteristics Supply voltage 3x380 V (-15 % %) Supply frequency 50 Hz (-15 % %) EMC filter DC reactor built-in built-in Control panel graphic, 160Х160 pixels, 3 Braking resistor PWM frequency / PWM carrier frequency Output frequency Frequency range for different motors Speed range Fixed speed accuracy (static) in vector control mode, without speed sensor Fixed speed accuracy (static) in vector control mode, with speed sensor Torque accuracy Overload characteristics Asynchronous motor control profile Cycle adjustment Slip compensation Local signaling Insulation Supply Number of analog inputs 2 Analog input type Sampling period Number of analog outputs 1 Type analog output Number of digital outputs Type of digital output Number of digital inputs 8 Type of digital inputs external 2 10 khz/5 khz Hz Hz 1:1000 in a closed-loop system with a speed sensor 1:100 in an open-loop system < 5 % at rated load of motor shaft and rated motor speed < 2 % at rated load of motor shaft and rated motor speed +/- 5 % in a closed-loop system +/- 10 % in an open-loop system 200 % for 2 seconds, 150 % for 60 seconds with an ambient temperature 50 С vector control in a closed-loop system with a speed feedback vector control in open-loop system without a speed feedback voltage / frequency U/F ratio control (scalar control) setting the operating mode MODBUS, digital inputs implemented run, ready, fault green, yellow and red LEDs isolated control circuits insulated custom circuits 10 V DC, +/- 2 % current not exceeding 30 ma, 24 V, 60 ma programmable ma, 0..5 ma, V 4 ms programmable ma, 0..5 ma, V 4 relay outputs 2 outputs are switching type 2 outputs are normally open type 24 V, input resistance: about 4 kohm PTC sensor, resistance switch 3 kohm/1,8 kohm emergency stop 1.4

11 Line 1 The logic of the digital input Acceleration and deceleration Type of protection Dielectric strength Insulation resistance Output frequency discreteness Communication protocol Physical interface Frame transmission Data transfer rate Data format Addresses number Access method Control options Electromagnetic compatibility 2 digital inputs arbitrary polarity S-shaped acceleration / deceleration, linear adjustable power switch (U, V, W, T) OCP hardware (U, V, W) / OCP software (U, V, W) temperature of switches Ud max/ Ud min loss of one or more phases overheating of the braking resistor motor overload /motor overheating for power circuits and auxiliary circuits having electrical communication with the power circuit 2500 V > 1 MOhm 0,1 Hz Modbus 2-wire RS-485 for Modbus RTU for Modbus bps bps up to 1 bps 8 bit, 1 stop bit, no parity addresses for Modbus slave Relative humidity 95 % The ambient temperature during operation / storage Operating altitude Standards Bluetooth module or Wi-Fi module EN class A, group 2, IEC/EN , category С2 with the additional EMC filter, EN class В, group 1, IEC/EN , category С C / C (humidity-controlled) up to 1000 m GOST , GOST , GOST , GOST , GOST , GOST , EN :2004, EN 55011, ЕN /

12 Model range Line 1 Triol AТ24 model Rated motor power, kw Rated current of power circuit, A Total VFD output power, kva 1 АТ24-5К ***** 5,5 11 7,5 АТ24-7К ***** 7, АТ24-11К-380-1***** 11, АТ24-15К-380-1***** 15, АТ24-18К-380-1***** 18, АТ24-22К-380-1***** 22, АТ24-30К-380-1***** 30, АТ24-37К-380-1***** 37, Mounting dimensions Triol AТ24 model L, mm H, mm D, mm АТ24-5К ***** АТ24-7К ***** АТ24-11К-380-1***** АТ24-15К-380-1***** АТ24-18К-380-1***** АТ24-22К-380-1***** АТ24-30К-380-1***** АТ24-37К-380-1***** holes Ø D 1.6

13 Line 1 Overall dimensions Triol AТ24 model Width, mm Height, mm Depth, mm АТ24-5К ***** АТ24-7К ***** АТ24-11К-380-1***** АТ24-15К-380-1***** АТ24-18К-380-1***** АТ24-22К-380-1***** АТ24-30К-380-1***** АТ24-37К-380-1***** VFD weight, kg 216, Dimensional outline АТ24-5К *****, АТ24-7К ***** 1.7

14 Dimensional outline АТ24-11К-380-1*****, АТ24-15К-380-1*****, АТ24-18К-380-1*****, АТ24-22К-380-1***** 1 Dimensional outline AТ24-30К-380-1*****, AТ24-37К-380-1***** 1.8

15 Line 2 2 Application Triol AT24 VFD Line 2 is a reliable solution for heating, ventilation and air conditioning applications. This product combines simplicity of management, operational reliability and high performance efficiency. Key functions start, stop and control of motor rotation frequency; acceleration and braking ramps including S-shaped ramps; reversal; acceleration, decreasing, stop; protection of the motor overcurrent, overload protection; motor control by external 2-wire and 3-wire sensors; saving control configuration of motor; dynamic braking of motor; simultaneous control of five motors («Cascade controller» macros); automatic control of technology process by closed-loop system principle using built-in PID-controller; operation of asynchronous motor by custom preset diagram in automatic or manual mode. 2.1

16 Protection functions 2 closedown under fuse blowing; variable frequency drive emergency tripping in case: temperature exceeds critical values increasing of voltage in DC-link decreasing of voltage in DC-link short-circuit at VFD output by a signal («Power switch» emergency) output current exceed preset values blocking of asynchronous motor reverse; disabling of VFD continuous duty under resonant frequencies for prevent an executive unit s damages; disabling of start-up after coast stop during specified time; after emergency, for protection against start-up of rotating motor; blocking of start-up after emergency tripping. Mechanical parameters plastic enclosure, IP20; forced cooling (fans, air flow direction from the bottom upwards); operation temperature -20 С С; simple connection of input and output cables; convenient demountable control panel with graphic display; possibility of installation in small-size cabinets or in confined space; resistance to continuous sinewave vibration 0.5 G in three plans. 2.2

17 Line 2 Power cables connection diagram (АТ24-5К5...11К) L1 L2 L3 PE Line-disconnection Grounding plate 2 Built-in EMC filter of Class C2 R/L1 S/L2 T/L3 +Rb and -Rb terminals are used only for connecting brake resistor -DC and +Rb terminals are used for connecting regeneration unit * +Ld and +Ud terminals are used for connecting the DC-link external choke +Rb -Rb -DC +Ld +Ud АС AT24-5K5...11K-380-2***** variable-frequency drive DC DC АС U/T1 V/T2 W/T3 du/dt filter * For variable-frequency drives w/o any built-in chokes in DC-link М 2.3

18 2 Technical characteristics Supply voltage 3х380 V (-15 %..+10 %) Supply frequency 50 Hz (-15 %..+10 %) EMC filter Discrete change of frequency assignments built-in 0,1 Hz Power factor > 0,95 Efficiency % Starting current Control laws Current limit Permissible cable length to the motor Braking DC reactor not higher than the calculated input current linear dependence U/f quadratic dependence U/f the programmable U/f in motoring and generative modes max 30 m (shielded)/max 50 m (unshielded) DC braking combined braking built-in Control panel graphic, 160X160 pixels, 3 Output frequency Braking resistor PWM frequency / PWM carrier frequency Frequency range for different motors Speed range Fixed speed accuracy (static) in vector control mode, without speed sensor Fixed speed accuracy (static) in vector control mode, with speed sensor Torque accuracy Overload characteristics Asynchronous motor control profile Cycle adjustment Slip compensation Local signaling Insulation Supply Number of analog inputs Hz external 2 10 khz/5 khz Hz 1:1000 in a closed-loop system with a speed sensor 1:100 in an open-loop system < 5 % at rated load of motor shaft and rated motor speed < 2 % at rated load of motor shaft and rated motor speed +/- 5 % in a closed-loop system +/- 10 % in an open-loop system 150 % for 2 seconds, 120 % for 60 seconds with an ambient temperature 50 С vector control in a closed-loop system with a speed feedback vector control in open-loop system without a speed feedback voltage / frequency U/F ratio control (scalar control) PID-controller implemented run, ready, fault green, yellow and red LEDs isolated control circuits insulated custom circuits 10 V DC, +/- 2 % current not exceeding 30 ma, 24 V, 60 ma 2.4

19 Line 2 Type analog input Sampling period Number of analog outputs 1 Type of analog output Number of digital outputs Type of digital outputs Number of digital inputs 8 Type of digital inputs The logic of the digital input Acceleration and deceleration Type of protection Dielectric strength Insulation resistance Output frequency discreteness Communication protocol Physical interface Frame transmission Data transfer rate Data format Addresses number Access method Control options Electromagnetic compatibility programmable ma, 0..5 ma, V 4 ms programmable ma, 0..5 ma, V 4 relay outputs 2 outputs are switching type 2 outputs are normally open type 24 V, input resistance: about 4 kohm PTC sensor, Resistance switch 3 kohm/1,8 kohm emergency stop 2 digital inputs arbitrary polarity S-shaped acceleration / deceleration, linear adjustable power switch (U, V, W, T) OCP hardware (U, V, W) / OCP software (U, V, W) temperature of switches Ud max/ Ud min loss of one or more phases overheating of the braking resistor motor overload /motor overheating for power circuits and auxiliary circuits having electrical communication with the power circuit 2500 V > 1 MOhm 0,1 Hz Modbus 2-wire RS-485 for Modbus RTU for Modbus bps bps up to 1 bps 8 bit, 1 stop bit, no parity addresses for Modbus slave Relative humidity 95 % The ambient temperature during operation / storage Standards Bluetooth module or Wi-Fi module EN class A, group 2, IEC/EN , category С2 with the additional EMC filter, EN class В, group 1, IEC/EN , category С C / C (humidity-controlled) GOST , GOST , GOST , GOST , GOST , GOST , EN :2004, EN 55011, ЕN /

20 Model range Line 2 Triol AТ24 model Rated motor power, kw Rated current of power circuit, A Total VFD output power, kva 2 АТ24-5К ***** 5,5 11 7,5 АТ24-7К ***** 7, АТ24-11К-380-2***** 11, АТ24-15К-380-2***** 15, АТ24-18К-380-2***** 18, АТ24-22К-380-2***** 22, АТ24-30К-380-2***** 30, АТ24-37К-380-2***** 37, АТ24-45К-380-2***** 45, АТ24-55К-380-2***** 55, Mounting dimensions Triol AТ24 model L, mm H, mm D, mm АТ24-5К ***** АТ24-7К ***** АТ24-11К-380-2***** АТ24-15К-380-2***** АТ24-18К-380-2***** АТ24-22К-380-2***** АТ24-30К-380-2***** АТ24-37К-380-2***** АТ24-45К-380-2***** АТ24-55К-380-2***** holes Ø D 2.6

21 Line 2 Overall dimensions Triol AТ24 model Width, mm Height, mm Depth, mm АТ24-5К ***** АТ24-7К ***** АТ24-11К-380-2***** АТ24-15К-380-2***** АТ24-18К-380-2***** АТ24-22К-380-2***** АТ24-30К-380-2***** АТ24-37К-380-2***** АТ24-45К-380-2***** АТ24-55К-380-2***** VFD weight, kg 216, Dimensional outline АТ24-5К *****, АТ24-7К *****, АТ24-11К-380-2***** 2.7

22 Dimensional outline АТ24-15К-380-2*****, АТ24-18К-380-2*****, АТ24-22К-380-2*****, АТ24-30К-380-2***** 2 Dimensional outline AТ24-37К-380-2*****, AТ24-45К-380-2*****, AТ24-55К-380-2***** 2.8

23 Line 3 3 Application Triol AT24 VFD Line 3 is specially designed for heating, ventilation and air conditioning systems. Metal enclosure with IP20 protection degree allows avoiding VFD s installation in the boxes and long cable routing. A large number of security and service functions makes this VFD multipurpose solution. Key functions start, stop and control of motor rotation frequency; acceleration and braking ramps including S-shaped ramps; reversal; acceleration, decreasing, stop; protection of the motor overcurrent, overload protection; motor control by external 2-wire and 3-wire sensors; saving control configuration of motor; dynamic braking of motor; simultaneous control of five motors («Cascade controller» macros); automatic control of technology processes by closed-loop system principle using built-in PID-controller; operation of asynchronous motor by custom preset diagram in automatic or manual mode. 3.1

24 Protection functions 3 closedown under fuse blowing; variable frequency drive emergency tripping in case: temperature exceed critical values increasing of voltage in DC-link decreasing of voltage in DC-link short-circuit at VFD output by a signal («Power switch» emergency) output current exceed preset values blocking of asynchronous motor reverse; disabling of VFD continuous duty under resonant frequencies for prevent an executive units damages; disabling of start-up after coast stop during specified time; after emergency, for protection against start-up of rotating motor; blocking of start-up after emergency tripping. Mechanical parameters plastic enclosure, IP20; forced cooling (fans, air flow direction from the bottom upwards); operation temperature -20 С С; simple connection of input and output cables; convenient demountable control panel with graphic display; possibility of installation in small-size cabinets or in confined space; resistance to continuous sinewave vibration 0.5 G in three plans. 3.2

25 Line 3 Power cables connection diagram Line-disconnection Terminal «Protective earthing» (PE) Panel for fixing ground cables and connecting cable shields 3 -DC and +Rb terminals are used for connecting regeneration unit AT24-75K...M A**** variable-frequency drive +Rb and -Rb terminals are used only for connecting brake resistor du/dt filter * Note. In VFD AT24-75K...M **** «-Rb» terminal do not used; it is reserve 3.3

26 3 Technical characteristics Supply voltage 3х380 V (-15 %..+10 %) Supply frequency 50 Hz (-15 %..+10 %) EMC filter Discrete change of frequency assignments built-in 0,1 Hz Power factor > 0,95 Efficiency % Starting current Control laws Current limit Permissible cable length to the motor Braking DC reactor not higher than the calculated input current linear dependence U/f quadratic dependence U/f the programmable U/f in motoring and generative modes max 30 m (shielded)/max 50 m (unshielded) DC braking combined braking built-in Control panel graphic, 160X160 pixels, 3 Output frequency Braking resistor PWM frequency / PWM carrier frequency Frequency range for different motors Speed range Fixed speed accuracy (static) in vector control mode, without speed sensor Fixed speed accuracy (static) in vector control mode, with speed sensor Torque accuracy Overload characteristics Asynchronous motor control profile Cycle adjustment Slip compensation Local signaling Insulation Supply Number of analog inputs Hz external 2 10 khz Hz 1:1000 in a closed-loop system with a speed sensor 1:100 in an open-loop system < 5 % at rated load of motor shaft and rated motor speed < 2 % at rated load of motor shaft and rated motor speed +/- 5 % in a closed-loop system +/- 10 % in an open-loop system 150 % for 2 seconds, 120 % for 60 seconds with an ambient temperature 50 С vector control in a closed-loop system with a speed feedback vector control in open-loop system without a speed feedback voltage / frequency U/F ratio control (scalar control) PID-controller implemented run, ready, fault green, yellow and red LEDs isolated control circuits insulated custom circuits 10 V DC, +/- 2 % current not exceeding 30 ma, 24 V, 60 ma 3.4

27 Line 3 Type analog input Sampling period Number of analog outputs 1 Type analog output Number of digital outputs Type of digital output Number of digital inputs 8 Type of digital input The logic of the digital input Acceleration and deceleration Type of protection Dielectric strength Insulation resistance Output frequency discreteness Communication protocol Physical interface Frame transmission Data transfer rate Data format Addresses number Access method Control options Electromagnetic compatibility programmable ma, 0..5 ma, V 4 ms programmable ma, 0..5 ma, V 4 relay outputs 2 outputs are switching type 2 outputs are normally open type 24 V, input resistance: about 4 kohm PTC sensor, Resistance switch 3 kohm/1,8 kohm emergency stop 2 digital inputs arbitrary polarity S-shaped acceleration / deceleration, linear adjustable power switch (U, V, W, T) OCP hardware (U, V, W) / OCP software (U, V, W) temperature of switches Ud max/ Ud min loss of one or more phases overheating of the braking resistor motor overload /motor overheating for power circuits and auxiliary circuits having electrical communication with the power circuit 2500 V > 1 MOhm 0,1 Hz Modbus 2-wire RS-485 for Modbus RTU for Modbus bps bps up to 1 bps 8 bit, 1 stop bit, no parity addresses for Modbus slave Relative humidity 95 % The ambient temperature during operation / storage Standards Bluetooth module or Wi-Fi module EN class A, group 2, IEC/EN , category С2 with the additional EMC filter, EN class В, group 1, IEC/EN , category С C / C (humidity-controlled) GOST , GOST , GOST , GOST , GOST , GOST , EN :2004, EN 55011, ЕN /

28 Model range Line 3 Model of Triol AT24 Rated motor power, kw Rated current of power circuit, A Total VFD output power, kva 3 АТ24-75К-380-3***** АТ24-90К-380-3***** АТ24-М ***** АТ24-М ***** АТ24-М ***** АТ24-М ***** АТ24-М ***** Mounting dimensions Triol AТ24 model L, mm H, mm D, mm АТ24-75К-380-3***** АТ24-90К-380-3***** ,5 АТ24-М ***** АТ24-М ***** 9 АТ24-М ***** АТ24-М ***** АТ24-М ***** holes Ø D 3.6

29 Line 3 Overall dimensions Triol AТ24 model Width, mm Height, mm Depth, mm АТ24-75К-380-3***** АТ24-90К-380-3***** АТ24-М ***** АТ24-М ***** АТ24-М ***** АТ24-М ***** АТ24-М ***** VFD weight, kg 528,5 803, Dimensional outline АТ24-75К-380-3*****, АТ24-90K-380-3*****, АТ24-М ***** 3.7

30 Dimensional outline АТ24-М *****, АТ24-М *****, АТ24-М *****, АТ24-М ***** 3 3.8

31 Line 4 4 Application Triol AT24 VFD Line 4 is known for its multifunctional performance and flexibility in such spheres of application as ventilation and air conditioning. Due to its optimal construction this VFD allows realization of a big variety of tasks. This makes the VFD universal solution. This line can be identified by high quality, easiness of access and simplicity of operation. Key functions start/reversal/stop of motor with assigned rates; changing and autonomic presetting an acceleration / deceleration time; connecting regenerative unit is available; frequency mode of motor deceleration; permit of resonant frequencies. 4.1

32 Protection functions 4 closedown under fuse blowing; variable frequency drive emergency tripping in case: temperature exceed critical values increasing of voltage in DC-link decreasing of voltage in DC-link short-circuit at VFD output by a signal («Power switch» emergency) output current exceed preset values blocking of asynchronous motor reverse; disabling of VFD continuous duty under resonant frequencies for prevent an executive units damages; disabling of start-up after coast stop during specified time; after emergency, for protection against start-up of rotating motor; blocking of start-up after emergency tripping. Mechanical parameters plastic enclosure, IP20; forced cooling (fans, air flow direction from the bottom upwards); operation temperature -10 С С; simple connection of input and output cables; convenient demountable control panel with 7-segment indicator; it is allowable an installation in small-size cabinets or in confined space; resistance to continuous sinewave vibration 0.5 G in three plans. 4.2

33 Line 4 Power cables connection diagram external braking converter external DC breaker external braking resistor AT24-37K...4K XXXXX Supply 380 V 50/60 Hz 4 Analog output V 0 20 ma Terminals High-speed impulse output Analog output V 0 20 ma +10V Supply for carrier frequency Relay output 1 Input VCT CCI Multifunctional analog input Relay output 2 4.3

34 4 Technical characteristics Supply voltage 3х380 V (-15 %..+10 %) Supply frequency 50 Hz (-15 %..+10 %) EMC filter Discrete change of frequency assignments built-in 0,1 Hz Power factor > 0,95 Efficiency % Starting current Control laws Current limit Permissible cable length to the motor Braking DC reactor Control panel Output frequency Braking resistor PWM frequency / PWM carrier frequency Frequency range for different motors Speed range Fixed speed accuracy (static) in vector control mode, without speed sensor Fixed speed accuracy (static) in vector control mode, with speed sensor Torque accuracy not higher than the calculated input current linear dependence U/f quadratic dependence U/f the programmable U/f in motoring and generative modes max 30 m (shielded)/max 50 m (unshielded) DC braking combined braking external, optional graphic Hz external khz Hz 1:1000 in a closed-loop system with a speed sensor 1:100 in an open-loop system < 5 % at rated load of motor shaft and rated motor speed < 2 % at rated load of motor shaft and rated motor speed +/- 5 % in a closed-loop system +/- 10 % in an open-loop system Overload characteristics 120 % for 60 seconds with an ambient temperature 45 С Motor control profile Cycle adjustment Slip compensation Local signaling Insulation Supply Number of analog inputs 1 Type analog input Sampling period vector/scalar PID-controller implemented run, ready, fault green, yellow and red LEDs isolated control circuits insulated custom circuits 10 V DC, +/- 2 % current not exceeding 30 ma, 24 V, 60 ma programmable ma, V 4 ms 4.4

35 Line 4 Number of analog outputs 2 Type analog output Number of digital outputs 6 Type of digital output Number of digital inputs 2 Type of digital input Acceleration and deceleration time Type of protection Dielectric strength Insulation resistance Output frequency discreteness Communication protocol Physical interface Frame transmission Data transfer rate Data format Addresses number Access method Control options Electromagnetic compatibility programmable ma, V 2 outputs are normally close type 2 outputs are normally open type 24 V, input resistance: about 4 kohm 0, s OCP hardware (U, V, W) / OCP software (U, V, W) Ud max/ Ud min loss of one or more phases indicator of DC-link charge for power circuits and auxiliary circuits having electrical communication with the power circuit 2500 V > 1 MOhm 0,1 Hz Modbus 2-wire RS-485 for Modbus RTU for Modbus bps bps up to 1 bps 8 bit, 1 stop bit, no parity addresses for Modbus slave Relative humidity 95 % The ambient temperature during operation / storage Standards Bluetooth module or Wi-Fi module EN class A, group 2, IEC/EN , category С C GOST , GOST , GOST , GOST , GOST , GOST , EN :2004, EN 55011, ЕN /

36 Model range Line 4 Model of Triol AT24 Rated motor power, kw Rated current of power circuit, A Total VFD output power, kva АТ24-К **** 0,75 1,5 1,0 АТ24-1К ***** 0,15 3,0 2,0 АТ24-2К ***** 0,22 4,5 3,0 АТ24-4К ***** 4,00 8,0 5,3 4 Mounting dimensions Triol AТ24 model L, mm H, mm D, mm АТ24-К **** АТ24-1К ***** АТ24-2К ***** АТ24-4К ***** ,5 7 Overall dimensions Triol AТ24 model Width, mm Height, mm Depth, mm VFD weight, kg АТ24-К **** АТ24-1К ***** АТ24-2К ***** АТ24-4К ***** Dimensional outline АТ24-К75...4К ***** D1 D H2 H1 H D2 2- d W1 W 4.6

37 Line C Application Triol AT24 VFD Line C is the best solution to increase the pumps productivity. This line is characterized by a robust construction, multifunctionality and flexibility. This drive is a great option to ensure smooth operation of equipment, increasing its life period thanks to the flexibility and modernity of the technical solutions. С Key functions start, stop and control the rotation frequency of pump s motor; acceleration and braking with assigned rates; reversal; acceleration, decreasing, stop; protection of the motor against overcurrent, overload protection; motor control by external 2-wire and 3-wire sensors; saving control configuration of motor; dynamic braking of motor; control five motors at the same time («Cascade controller» macros); automatic control of technology processes by closed-loop system principle using built-in PID-controller; automatically restart asynchronous motor after supply voltage failure or after special emergencies of motor (customized emergencies); operation of asynchronous motor by custom preset diagram in automatic or manual mode. C.1

38 Protection functions closedown under fuse blowing; variable frequency drive emergency tripping in case: temperature exceed critical values increasing of voltage in DC-link decreasing of voltage in DC-link short-circuit at VFD output by a signal («Power switch» emergency) output current exceed preset values blocking of asynchronous motor reverse; disabling of VFD continuous duty under resonant frequencies for prevent an executive units damages; disabling of start-up after coast stop during specified time; after emergency, for protection against start-up of rotating motor; blocking of start-up after emergency tripping. Mechanical parameters С plastic enclosure, IP54; forced cooling (fans, air flow direction from the bottom upwards); operation temperature -20 oс С; simple connection of input and output cables; convenient demountable control panel with graphic display; it is allowable an installation in small-size cabinets or in confined space; resistance to continuous sinewave vibration 0.5 G in three plans. C.2

39 Line C Power cables connection diagram (АТ24-5К5...11К) Line-disconnection Grounding plate +Rb and -Rb terminals are used only for connecting brake resistor -DC and +Rb terminals are used for connecting regeneration unit AT24-5K5...11K-380-C***** variable-frequency drive С +Ld and +Ud terminals are used for connecting the DC-link external choke du/dt filter * For variable-frequency drives w/o any built-in chokes in DC-link C.3

40 Power cables connection diagram (АТ24-15К...30К) Line-disconnection Grounding plate +Rb and -Rb terminals are used only for connecting brake resistor * AT24-15K...30K-380-C***** variable-frequency drive С +DC and -DC terminals are used for connecting regeneration unit du/dt filter * +DC and -DC terminals are brought out in variable speed drives w/o built-in braking unit; +Rb and -Rb terminals are brought out in variable speed drives with built-in braking unit C.4

41 Line C Power cables connection diagram (АТ24-37К...55К) Line-disconnection Grounding plate -DC and +Rb terminals are used for connecting regeneration unit AT24-37K...55K-380-C***** variable-frequency drive +Rb and -Rb terminals are used only for connecting brake resistor С du/dt filter C.5

42 С Technical characteristics Supply voltage 3х380 V (-15 %..+10 %) Supply frequency 50 Hz (-15 %..+10 %) EMC filter DC reactor external built-in Control panel graphic, 160X160 pixels, 3 Output frequency Discrete change of frequency assignments Hz 0,1 Hz Power factor > 0,93 Efficiency % Starting current Current limit Control laws Acceleration and deceleration time Permissible cable length to the motor Braking Braking resistor PWM frequency / PWM carrier frequency Frequency range for different motors Speed range Fixed speed accuracy (static) in vector control mode, without speed sensor Fixed speed accuracy (static) in vector control mode, with speed sensor Torque accuracy Overload characteristics Asynchronous motor control profile Cycle adjustment Slip compensation Local signaling Insulation Supply Number of analog inputs 2 not higher than the calculated input current in motoring and generative modes linear dependence U/f quadratic dependence U/f the programmable U/f s max 30 m (shielded)/max 50 m (unshielded) DC braking combined braking external 2 10 khz Hz 1:1000 in a closed-loop system with a speed sensor 1:100 in an open-loop system < 5 % at rated load of motor shaft and rated motor speed < 2 % at rated load of motor shaft and rated motor speed +/- 5 % in a closed-loop system +/- 10 % in an open-loop system 120 % from rated value for 120 s, averaging time 10 min vector control in a closed-loop system with a speed feedback vector control in open-loop system without a speed feedback voltage / frequency U/F ratio control (scalar control) PID-controller implemented run, ready, fault green, yellow and red LEDs isolated control circuits insulated custom circuits 10 V DC, +/- 2 % current not exceeding 30 ma, 24 V, 60 ma C.6

43 Line C Type analog inputs Sampling period Number of analog outputs 1 Type analog output Number of digital outputs Type of digital output Digital outputs with custom logic (PNP or NPN) Number of digital inputs 8 Type of digital input Acceleration and deceleration Type of protection Dielectric strength Insulation resistance Communication protocol Physical interface Frame transmission Data transfer rate Data format Addresses number Access method Control options Electromagnetic compatibility Relative humidity Optional unit Standards programmable ma,, 0..5 ma,, V 4 ms programmable ma, 0..5 ma, V 4 relay outputs 2 outputs are normally close type 2 outputs are normally open type 6 24 V, input resistance: about 4 kohm PTC sensor, Resistance switch 3 kohm/1,8 kohm emergency stop S-shaped acceleration / deceleration, linear adjustable power switch (U, V, W, T) OCP hardware (U, V, W) / OCP software (U, V, W) temperature of switches Ud max/ Ud min loss of one or more phases overheating of the braking resistor motor overload /motor overheating for power circuits and auxiliary circuits having electrical communication with the power circuit 2500 V > 1 MOhm Modbus 2-wire RS-485 for Modbus RTU for Modbus bps bps up to 1 bps 8 bit, 1 stop bit, no parity addresses for Modbus slave Bluetooth module or Wi-Fi module EN class A, group 2, IEC/EN , category С3 with the additional EMC filter, EN class В, group 1, IEC/EN , category С1 80 % at a temperature of +20 С (with no condensation) «ЕХТ1» unit, for expand numbers of input / output GOST , GOST , GOST , GOST , GOST , GOST , EN :2004, EN 55011, ЕN /4 С C.7

44 Model range Line C Model of Triol AT24 Rated motor power, kw Rated current of power circuit, A Total VFD output power, kva АТ24-5К5-380-C***** 5,5 11 7,5 АТ24-7К5-380-C***** 7, АТ24-11К-380-C***** 11, АТ24-15К-380-C***** 15, АТ24-18К-380-C***** 18, АТ24-22К-380-C***** 22, АТ24-30К-380-C***** 30, АТ24-37К-380-C***** 37, АТ24-45К-380-C***** 45, АТ24-55К-380-C***** 55, Mounting dimensions 4 holes Ø D С Triol AТ24 model L, mm H, mm D, mm АТ24-5К5-380-С***** АТ24-7К5-380-С***** АТ24-11К-380-С***** АТ24-15К-380-С***** АТ24-18К-380-С***** АТ24-22К-380-С***** АТ24-30К-380-С***** АТ24-37К-380-С***** АТ24-45К-380-С***** АТ24-55К-380-С***** C.8

45 Line C Overall dimensions Triol AТ24 model Width, mm Height, mm Depth, mm АТ24-5К5-380-C***** АТ24-7К5-380-C***** АТ24-11К-380-C***** АТ24-15К-380-C***** АТ24-18К-380-C***** АТ24-22К-380-C***** АТ24-30К-380-C***** АТ24-37К-380-C***** АТ24-45К-380-C***** АТ24-55К-380-C***** VFD weight, kg Dimensional outline АТ24-5К5-380-С*****, АТ24-7К5-380-С*****, АТ24-11К-380-С***** С C.9

46 Dimensional outline АТ24-15К-380-С*****, АТ24-18К-380-С*****, АТ24-22К-380-С*****, АТ24-30К-380-С***** С Dimensional outline АТ24-37К-380-С*****, АТ24-45К-380-С*****, АТ24-55К-380-С*****. C.10

47 Line Е Application Triol AT24 line E is specially designed in accordance with many exploitation specifics for pumps and fans control. Application of such a VFD provides reduced power consumption and smooth operation of the equipment. Such a multifunctional and reliable solution will not only implement the current tasks, but also prolong the equipment lifetime. Key functions Е start, stop and control the rotation frequency of pump s motor; acceleration and braking with assigned rates; reversal; acceleration, decreasing, stop; protection of the motor against overcurrent, overload protection; motor control by external 2-wire and 3-wire sensors; saving control configuration of motor; dynamic braking of motor; control five motors at the same time («Cascade controller» macros); automatic control of technology processes by closed-loop system principle using built-in PID-controller; automatically restart asynchronous motor after supply voltage failure or after special emergencies of motor (customized emergencies); operation of asynchronous motor by custom preset diagram in automatic or manual mode. Е.1

48 Protection functions closedown under fuse blowing; variable frequency drive emergency tripping in case: temperature exceed critical values increasing of voltage in DC-link decreasing of voltage in DC-link short-circuit at VFD output by a signal («Power switch» emergency) output current exceed preset values blocking of asynchronous motor reverse; disabling of VFD continuous duty under resonant frequencies for prevent an executive units damages; disabling of start-up after coast stop during specified time; after emergency, for protection against start-up of rotating motor; blocking of start-up after emergency tripping. Mechanical parameters metal enclosure, IP20; forced cooling (fans, air flow direction from the bottom upwards); operation temperature -20 С С; simple connection of input and output cables; convenient demountable control panel with graphic display; it is allowable an installation in small-size cabinets or in confined space; resistance to continuous sinewave vibration 0.5 G in three plans. Е Е.2

49 Line Е Power cables connection diagram (АТ24-75К..М11) Line-disconnection Terminal «Protective earthing» (PE) Panel for fixing ground cables and connecting cable shields +Rb and -DC terminals are used for connecting regeneration unit AT24-75K...M EA**** variable-frequency drive +Rb and -Rb terminals are used only for connecting brake resistor Е du/dt filter Е.3

50 Е Technical characteristics Supply voltage 3х380 V (-15 %..+10 %) Supply frequency 50 Hz (-15 %..+10 %) EMC filter DC reactor external built-in Control panel graphic, 160X160 pixels, 3 Output frequency Discrete change of frequency assignments Hz 0,1 Hz Power factor > 0,93 Efficiency % Starting current Current limit Control laws Acceleration and deceleration time Permissible cable length to the motor Braking Braking resistor PWM frequency / PWM carrier frequency Frequency range for different motors Speed range Fixed speed accuracy (static) in vector control mode, without speed sensor Fixed speed accuracy (static) in vector control mode, with speed sensor Torque accuracy Overload characteristics Asynchronous motor control profile Cycle adjustment Slip compensation Local signaling Insulation Supply Number of analog inputs 2 not higher than the calculated input current in motoring and generative modes linear dependence U/f quadratic dependence U/f the programmable U/f s max 30 m (shielded)/max 50 m (unshielded) DC braking combined braking external 2 10 khz Hz 1:1000 in a closed-loop system with a speed sensor 1:100 in an open-loop system < 5 % at rated load of motor shaft and rated motor speed < 2 % at rated load of motor shaft and rated motor speed +/- 5 % in a closed-loop system +/- 10 % in an open-loop system 120 % from rated value for 120 s, averaging time 10 min vector control in a closed-loop system with a speed feedback vector control in open-loop system without a speed feedback voltage / frequency U/F ratio control (scalar control) PID-controller implemented run, ready, fault green, yellow and red LEDs isolated control circuits insulated custom circuits 10 V DC, +/- 2 % current not exceeding 30 ma, 24 V, 60 ma Е.4

51 Line Е Type analog inputs Sampling period Number of analog outputs 1 Type analog output Number of digital outputs Type of digital output Digital outputs with custom logic (PNP or NPN) Number of digital inputs 8 Type of digital input Acceleration and deceleration Type of protection Dielectric strength Insulation resistance Communication protocol Physical interface Frame transmission Data transfer rate Data format Addresses number Access method Control options Electromagnetic compatibility Relative humidity Optional unit Standards programmable ma,, 0..5 ma,, V 4 ms programmable ma, 0..5 ma, V 4 relay outputs 2 outputs are switching type 2 outputs are normally open type 6 24 V, input resistance: about 4 kohm PTC sensor, Resistance switch 3 kohm/1,8 kohm emergency stop S-shaped acceleration / deceleration, linear adjustable power switch (U, V, W, T) OCP hardware (U, V, W) / OCP software (U, V, W) temperature of switches Ud max/ Ud min loss of one or more phases overheating of the braking resistor motor overload /motor overheating for power circuits and auxiliary circuits having electrical communication with the power circuit 2500 V > 1 MOhm Modbus 2-wire RS-485 for Modbus RTU for Modbus bps bps up to 1 bps 8 bit, 1 stop bit, no parity addresses for Modbus slave Bluetooth module or Wi-Fi module EN class A, group 2, IEC/EN , category С3 with the additional EMC filter, EN class В, group 1, IEC/EN , category С1 80 % at a temperature of +20 С (with no condensation) «ЕХТ1» unit, for expand numbers of input / output GOST , GOST , GOST , GOST , GOST , GOST , EN :2004, EN 55011, ЕN /4 Е Е.5

52 Model range Line Е Model of Triol AT24 Rated motor power, kw Rated current of power circuit, A Total VFD output power, kva АТ24-75К-380-Е***** АТ24-90К-380-Е***** АТ24-М Е***** Mounting dimensions 4 holes Ø D Е Triol AТ24 model L, mm H, mm D, mm АТ24-75К-380-Е***** АТ24-90К-380-Е***** АТ24-М Е***** Overall dimensions Triol AТ24 model Width, mm Height, mm Depth, mm АТ24-75К-380-Е***** АТ24-90К-380-Е***** АТ24-М Е***** VFD weight, kg Е.6

53 Line Е Dimensional outline АТ Е*****, АТ24-90К-380-Е*****, АТ24-М Е**** Е Е.7

54 Е.8

55 Line H Application Triol AT24 VFD Line H is a multifunction system that provides control of asynchronous electric pumps for various purposes. This Line can be used to solve multiple issues that require use of equipment in difficult conditions with maximum protection. Key functions Н/380 V start, stop and control the rotation frequency of pump s motor; acceleration and braking with assigned rates; reversal; acceleration, decreasing, stop; protection of the motor against overcurrent, overload protection; motor control by external 2-wire and 3-wire sensors; saving control configuration of motor; dynamic braking of motor; control five motors at the same time («Cascade controller» macros); automatic control of technology processes by closed-loop system principle using built-in PID-controller; automatically restart asynchronous motor after supply voltage failure or after special emergencies of motor (customized emergencies); operation of asynchronous motor by custom preset diagram in automatic or manual mode. Н.1

56 Protection functions closedown under fuse blowing; variable frequency drive emergency tripping in case: temperature exceed critical values increasing of voltage in DC-link decreasing of voltage in DC-link short-circuit at VFD output by a signal («Power switch» emergency) output current exceed preset values blocking of asynchronous motor reverse; disabling of VFD continuous duty under resonant frequencies for prevent an executive units damages; disabling of start-up after coast stop during specified time; after emergency, for protection against start-up of rotating motor; blocking of start-up after emergency tripping. Mechanical parameters metal enclosure, IP54; forced cooling (fans, air flow direction from the bottom upwards); operation temperature -20 С С; simple connection of input and output cables; convenient demountable control panel with graphic display; it is allowable an installation in small-size cabinets or in confined space; resistance to continuous sinewave vibration 0.5 G in three plans. Н/380 V Н.2

57 Line H Power cables connection diagram (АТ24-5К5...55К) Line-disconnection Choke in DC link +Rb and -Rb terminals are used only for connecting brake resistor AT24-5K5...55K-380-H***** variable frequency drive du/dt filter Н/380 V Н.3

58 Н/380 V Н.4 Technical characteristics Supply voltage 3х380 V (-15 %..+10 %) Supply frequency 50 Hz (-15 %..+10 %) EMC filter DC reactor external built-in Control panel graphic, 160X160 pixels, 3 Output frequency Discrete change of frequency assignments Hz 0,1 Hz Power factor > 0,93 Efficiency % Starting current Current limit Control laws Acceleration and deceleration time Permissible cable length to the motor Braking Braking resistor PWM frequency / PWM carrier frequency Frequency range for different motors Speed range Fixed speed accuracy (static) in vector control mode, without speed sensor Fixed speed accuracy (static) in vector control mode, with speed sensor Torque accuracy Overload characteristics Asynchronous motor control profile Cycle adjustment Slip compensation Local signaling Insulation Supply Number of analog inputs 2 not higher than the calculated input current in motoring and generative modes linear dependence U/f quadratic dependence U/f the programmable U/f s max 30 m (shielded)/max 50 m (unshielded) DC braking combined braking external 2 10 khz Hz 1:1000 in a closed-loop system with a speed sensor 1:100 in an open-loop system < 5 % at rated load of motor shaft and rated motor speed < 2 % at rated load of motor shaft and rated motor speed +/- 5 % in a closed-loop system +/- 10 % in an open-loop system 120 % from rated value for 120 s, averaging time 10 min vector control in a closed-loop system with a speed feedback vector control in open-loop system without a speed feedback voltage / frequency U/F ratio control (scalar control) PID-controller implemented run, ready, fault green, yellow and red LEDs isolated control circuits insulated custom circuits 10 V DC, +/- 2 % current not exceeding 30 ma, 24 V, 60 ma

59 Line H Type analog inputs Sampling period Number of analog outputs 1 Type analog output Number of digital outputs Type of digital output Digital outputs with custom logic (PNP or NPN) Number of digital inputs 8 Type of digital input Acceleration and deceleration Type of protection Dielectric strength Insulation resistance Communication protocol Physical interface Frame transmission Data transfer rate Data format Addresses number Access method Control options Electromagnetic compatibility Relative humidity Optional unit Standards programmable ma,, 0..5 ma,, V 4 ms programmable ma, 0..5 ma, V 4 relay outputs 2 outputs are switching type 2 outputs are normally open type 6 24 V, input resistance: about 4 kohm PTC sensor, Resistance switch 3 kohm/1,8 kohm emergency stop S-shaped acceleration / deceleration, linear adjustable power switch (U, V, W, T) OCP hardware (U, V, W) / OCP software (U, V, W) temperature of switches Ud max/ Ud min loss of one or more phases overheating of the braking resistor motor overload /motor overheating for power circuits and auxiliary circuits having electrical communication with the power circuit 2500 V > 1 MOhm Modbus 2-wire RS-485 for Modbus RTU for Modbus bps bps up to 1 bps 8 bit, 1 stop bit, no parity addresses for Modbus slave Bluetooth module or Wi-Fi module EN class A, group 2, IEC/EN , category С3 with the additional EMC filter, EN class В, group 1, IEC/EN , category С1 80 % at a temperature of +20 С (with no condensation) «ЕХТ1» unit, for expand numbers of input / output GOST , GOST , GOST , GOST , GOST , GOST , EN :2004, EN 55011, ЕN /4 Н/380 V H.5

Frequency Converter Fv

Frequency Converter Fv 2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)

More information

32VFD Variable Frequency Drives for Centrifugal Chillers

32VFD Variable Frequency Drives for Centrifugal Chillers 32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why

More information

EFC 3600. Frequency converters

EFC 3600. Frequency converters 2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation

More information

Easy to connect - Easy to configure Easy to install

Easy to connect - Easy to configure Easy to install SIMPLE TO USE... CG Drive- SK is an easy drive - easy to connect, easy to configure and easy to install. Easy to connect - All connectors are generously sized and clearly labeled. Easy to configure - The

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

NXL Series Inverters. HVAC Inverters made simple

NXL Series Inverters. HVAC Inverters made simple NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter

More information

TRAMS TROLLEY-BUSES SUBWAY

TRAMS TROLLEY-BUSES SUBWAY 9 FT-100-600 Traction Inverter for Asynchronous Drives 11 FT-105-600 Traction Inverter for Asynchronous Drives 13 FT-170-600 Traction Inverter for Asynchronous Drives 15 FT-300-600 Traction Inverter for

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections

More information

ABB general machinery drives. User s manual ACS355 drives

ABB general machinery drives. User s manual ACS355 drives ABB general machinery drives User s manual ACS355 drives List of related manuals Drive manuals and guides Code (English) ACS355 user s manual 3AUA0000066143 1) ACS355 drives with IP66/67 / UL Type 4x enclosure

More information

3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives

3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives 3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

Manual No. YEG-TOE-S616-55.1-OY. VARISPEED F7 Vector Control Frequency Inverter USER S MANUAL

Manual No. YEG-TOE-S616-55.1-OY. VARISPEED F7 Vector Control Frequency Inverter USER S MANUAL Manual No. YEG-TOE-S616-55.1-OY VARISPEED F7 Control Frequency Inverter USER S MANUAL Table of Content Warnings... VII Safety Precautions and Instructions for Use... VIII EMC Compatibility... X Line Filters...

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC

More information

MC Series Drives. Flexible, simple, rugged, robust! Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.

MC Series Drives. Flexible, simple, rugged, robust! Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives. Drives Flexible, simple, rugged, robust! Our promise Commitment to Price Leadership Price leadership is serious business. It takes continuous life cycle management to make price leadership a sustainable

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Products and solutions for lifting systems

Products and solutions for lifting systems Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded

More information

VARIABLE FREQUENCY DRIVES Revised 4/30/2015 23 81 07-1 Mechanical Systems

VARIABLE FREQUENCY DRIVES Revised 4/30/2015 23 81 07-1 Mechanical Systems SECTION 23 81 07 - VARIABLE FREQUENCY DRIVES PART 1 - GENERAL 1.1 SUMMARY A. This section includes all variable frequency drives. All standard and optional features shall be included within the VFD panel

More information

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS SPECIFICATIONS PRODUCT DATA Mains Connection Input voltage U in 380 500 Vac (±10%), 3~ Input Frequency 45 66 Hz Connection to mains Once per minute

More information

... Electronic Softstarter...

... Electronic Softstarter... . CT-START Electronic Softstarter. 6 A. to 900. A......... CT START CT-START is a multi-function electronic system with a microcontroller and thyristors, designed for use with all 3-phase squirrel cage

More information

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

VLT Series 3500 Adjustable Frequency Drive Instruction Manual Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software

More information

ABB machinery drives. User s manual ACS355 drives

ABB machinery drives. User s manual ACS355 drives ABB machinery drives User s manual ACS355 drives List of related manuals Drive manuals and guides ACS355 user s manual ACS355 drives with IP66/67 / UL Type 4x enclosure supplement ACS355 quick installation

More information

Siemens Standard Drives. Application Handbook

Siemens Standard Drives. Application Handbook Siemens Standard Drives Application Handbook Martin Brown Siemens Standard Drives Congleton December 1997 1. Introduction....4 1.1 What is a Variable Speed Drive?...4 1.2 The Variable Frequency Inverter...7

More information

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY PowerGate - Cost effective solutions for F 1 Horsepower Rating 001 1-40 HP (208V) 075 1-75 HP (480V) Input Voltage 2V 208-240V 4V 380-480V Disconnect

More information

GPD 506/P5 Start-up Procedure and Checklist

GPD 506/P5 Start-up Procedure and Checklist GPD 506/P5 Start-up Procedure and Checklist Preparation for GPD506/P5 Drive Start-Up...2 HVAC Start-Up Procedure for GPD 506/P5 WITH Bypass Option:...4 HVAC Start-Up Procedure for GPD 506/P5 WITHOUT Bypass

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3 Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

with Electronic Assistant

with Electronic Assistant TECHNICAL DATASHEET #TDAX100200 BLDC Motor Drive Drives a 12V, 24V or 48V BLDC motor Bidirectional, up to 25A Smooth speed control using Hall Sensors CAN (SAE J1939) with Electronic Assistant Features:

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

FRENIC5000MS5 for Machine Tool Spindle Drives

FRENIC5000MS5 for Machine Tool Spindle Drives FRENIC5MS5 for Machine Tool Spindle Drives Yoshikazu Tanaka Hiroaki Hayashi Hiroshi Takahashi 1. Introduction Fig.1 External view of FRENIC5MS5 In AC spindle drive systems for machine tools, operation

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS D R I V E S Y S T E M S PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS The vision of Iskra Avtoelektrika is to be: One of the world's leading manufacturers of electric motors and controllers for

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry. The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion

More information

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB. Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

Low voltage AC drives. ABB industrial drives ACS800, single drives 0.55 to 5600 kw Catalog

Low voltage AC drives. ABB industrial drives ACS800, single drives 0.55 to 5600 kw Catalog Low voltage AC drives ABB industrial drives ACS800, single drives 0.55 to 5600 kw Catalog Selecting and ordering your drive Build up your own ordering code using the type designation key below or contact

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Variable speed drives

Variable speed drives 5 192 Variable speed drives SED2 Variable speed drives for speed control of three-phase a.c. motors actuating fans or pumps. Range: 0.37 kw to 90 kw for IP20, IP21 version, 1.1 kw to 90 kw for IP54 version.

More information

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits: Variable Frequency Drives (or VFDs) are becoming almost standard part of aquatics equipment room packages. Most VFDs are fairly simple to install and operate however, they are quite complex with respect

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information

ABB PSPS Erich Steinmann; Generator control-2013

ABB PSPS Erich Steinmann; Generator control-2013 ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02

More information

J1000. System configuration

J1000. System configuration YASKAWA JZ J1000 The basic inverter V/f controlled inverter Good torque performance (150% / 3 Hz) Double rating ND 120%/1min and HD 150%/1 min Overload detection function (150% during 60s) thermal function

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

VLT AutomationDrive for Marine winch applications

VLT AutomationDrive for Marine winch applications MAKING MODERN LIVING POSSIBLE VLT APPLICATION NOTE VLT AutomationDrive for Marine winch applications This Application note is meant to be a guideline for using Danfoss VLT AutomationDrive in winch applications.

More information

PROGRAMMABLE SINGLE-AXIS SERVO DRIVE A MODULE OF THE MSD SYSTEM

PROGRAMMABLE SINGLE-AXIS SERVO DRIVE A MODULE OF THE MSD SYSTEM PROGRAMMABLE SINGLE-AXIS SERVO DRIVE A MODULE OF THE MSD SYSTEM DELIVERING ADVANCED MOTION CONTROL AND FLEXIBILITY FOR HIGH PERFORMANCE AXES APPLICATIONS WHAT MOVES YOUR WORLD INTRODUCTION Whenever the

More information

VCM Installation and Operations Manual. Table of Contents

VCM Installation and Operations Manual. Table of Contents Table of Contents VCM Installation and Operations Manual 1.0 Introduction... 1 2.0 Product Inspection... 2 2.1 Nameplate Layout... 2 3.0 Operating Precautions... 3 3.1 Before Power up... 3 3.2 During Power

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Discover the power of e-learning! The Quick Guide to AC Variable Frequency

Discover the power of e-learning! The Quick Guide to AC Variable Frequency The Quick Guide to AC Variable Frequency This ebook is meant as an easy guide to any electrical or electronic engineer or technician, who would like to know how modern ac variable frequency drives work.

More information

How To Use The Vacon 0 Machinery

How To Use The Vacon 0 Machinery vacon 0 machinery how would you like your ac drive today? easy adaptation for customer requirements The Vacon 0 Machinery is an extremely compact AC drive for machine builders in the power range from 0.25

More information

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP 200 480V Single & 3 Phase Input

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP 200 480V Single & 3 Phase Input AC Variable Speed Drive Powerful Performance Advanced motor control 0.75kW 250kW / 1HP 350HP 200 480V Single & 3 Phase Input At a Glance High performance, excellent usability and flexible to meet the needs

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Series: IDAM Servo Drive E Digital Motor Drive - DMD-078.12

Series: IDAM Servo Drive E Digital Motor Drive - DMD-078.12 Series: IDAM Servo Drive E Digital Motor Drive - DMD-078.12 inside Integrated amplifiers for 8 single-phase motors, 4 two-phases motors or 4 three-phases motors or combinations of them in one device Position

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3 2 Phase Stepping Motor Driver 2M542 OPEATING MANUAL Table of contents Introduction page 2 Specifications page 2 Timing chart page 3 Setting page 4 Current set page 4 educe current function page 4 Micro

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning

More information

Current and voltage measuring relays

Current and voltage measuring relays Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application

More information