1 671 LASER WAVELENGTH METER It s Our Business to be EXACT For laser applications such as high-resolution laser spectroscopy, photo-chemistry, cooling/trapping, and optical remote sensing, wavelength information is critical. However, the exact wavelength of a variety of lasers, such as tunable lasers and laser diodes, is not known a priori. Therefore, it is necessary to measure laser wavelength to ensure the most meaningful experimental results. The best way to determine the absolute wavelength of CW or quasi-cw lasers is with the 671 Laser Wavelength Meter from Bristol Instruments. The 671 system employs optical interferometry to measure absolute wavelength to the highest guaranteed accuracy, providing real-time laser wavelength information guaranteed by continuous calibration with a built-in wavelength standard. The result is the reliable accuracy that is required for the most demanding applications. What s more, this is accomplished with an unprecedented level of reliability and convenience. Absolute wavelength measured to an accuracy as high as ±.1 nm Continuous calibration with a built-in wavelength standard Operation available from 375 nm to 12 µm Simultaneous measurement of total optical power to an accuracy of ± 15% Measurement rate as high as 1 Hz Input power requirement as low as 1 µw Displays wavelength, wavenumber, or frequency Convenient pre-aligned fiber-optic input for visible and NIR wavelengths Free-space aperture with visible tracer beam for IR and MIR wavelengths Straightforward operation with PC using USB or Ethernet interfaces Web-based application available for tablet or smart phone display Easy to integrate into experiment for automatic wavelength reporting and control

2 RELIABLE ACCURACY FOR GREATER CONFIDENCE the model 671B is a lower-priced alternative with a wavelength accuracy of ±.75 parts per million. The MIR version of the model 671B, however, has a wavelength accuracy of ± 1 part per million. Accuracy in Wavelength Units 671B 671B-MIR 671A Accuracy in Frequency Units 671B 671B-MIR 671A Accuracy (pm) Accuracy (MHz) GUARANTEED ACCURACY The most important aspect of a laser wavelength meter is its accuracy. Bristol Instruments guarantees this specification by taking into account all factors that can affect wavelength measurement. Wavelength accuracy is quantified by Bristol Instruments using the NIST definition for expanded uncertainty. Components of error arising from both systematic and random effects are included. Systematic errors result in an offset between the measured value and the true value. Random errors result in measurements that have a statistical distribution associated with short-term measurement repeatability. The 671 system is designed to address both types of uncertainty. Continuous calibration with a built-in wavelength standard corrects for potential sources of systematic error. Random errors are minimized with a robust Michelson interferometer design. Long-term wavelength measurement data of a DFB laser locked to an absorption line of acetylene. The specified accuracy is given by the dashed lines. 2

3 671 SERIES LASER WAVELENGTH METER CONTINUOUS CALIBRATION To achieve the reliable accuracy that is expected from Bristol Instruments, the model 671 is continuously calibrated with a built-in HeNe laser wavelength standard. The HeNe laser is an ideal reference source because its wavelength is well-known and fixed by fundamental atomic structure. To measure wavelength to the highest accuracy of ±.2 parts per million, the 671A system uses a stabilized single-frequency HeNe laser as a wavelength reference. This laser is stabilized by using a very reliable balanced longitudinal mode technique. A standard HeNe laser is used with the model 671B to achieve an accuracy of ±.75 parts per million EXCEPTIONAL REPEATABILITY The design of the 671 Laser Wavelength Meter is based on a rigorous understanding of Michelson interferometer technology and how it is applied to laser wavelength measurement. This results in exceptional measurement repeatability, defined as the standard deviation for a five-minute period after the instrument has reached thermal equilibrium. The repeatability specification for the model 671A is ±.3 parts per million (±.6 parts per million for the IR version). The model 671B has a repeatibility specification of±.1 part per million. This performance ensures that all wavelength measurements are well within the specified accuracy limits. The exceptional repeatability of the 671 Laser Wavelength Meter provides the ability to detect small changes in laser wavelength. That is, the wavelength resolution of the 671 system is approximately two times the specified repeatability. Therefore, the model 671A has a wavelength resolution of about.6 parts per million (.6 pm at 1 nm), and the wavelength resolution of the model 671B is about.2 parts per million (.2 pm at 1 nm). PRECISE INTERFEROMETER TECHNOLOGY Several methods are available to measure laser wavelength. Bristol Instruments uses optical interferometry for the model 671 because such techniques have been proven to be the most precise and reliable for wavelength measurement instrumentation. A Michelson interferometer is used to generate information from the interference of two beams that originate from the same source. The optical input (depicted in blue) is split between a fixed path and a path that is smoothly changing in length. Both beams are reflected and recombined to produce an interference pattern that is a consequence of the changing phase relationship between the beams. The model 671 generates interference patterns simultaneously from the laser under test and from a built-in HeNe reference laser (depicted in red) that is travelling the same optical path but in the opposite direction. By comparing these interference patterns, the wavelength under test can be determined accurately. Michelson Interferometer Schematic 3

4 OPERATION The 671 Laser Wavelength Meter measures absolute laser wavelength with an unsurpassed level of versatility and convenience. Four broad wavelength configurations are available, laser input is straightforward, and the system has a very high sensitivity. Wavelength is calculated using an on-board digital signal processor and then displayed on a PC, tablet, or smart phone. What s more, it is easy to integrate the 671 Laser Wavelength Meter into an experiment for automatic wavelength reporting or control. BROAD WAVELENGTH COVERAGE The model 671 is available in four broad wavelength configurations to satisfy virtually any experimental requirement. These ranges are the VIS ( nm), NIR (52-17 nm), IR (1-5 µm), and MIR ( µm). VIS ( nm) NIR (52-17 nm) IR (1-5 µm) MIR ( µm) CONVENIENT LASER INPUT A laser under test enters the VIS and NIR versions of the model 671 through a pre-aligned FC/PC fiber-optic input connector. This ensures optimum alignment of the laser beam to the instrument s interferometer resulting in uncompromised accuracy. With fiber-optic input, the 671 system can be placed in an out of the way location, thereby conserving valuable optical real-estate. For free beam lasers, Bristol Instruments offers the LC-1 Fiber-Optic Input Coupler, a simple way to launch a laser beam into fiber. Since fiber is not readily available for infrared wavelengths, the laser under test enters the IR and MIR versions of the model 671 through an input aperture. To facilitate alignment to the instrument, the internal HeNe reference laser is emitted from the input aperture as a visible tracer beam. The laser under test is simply superimposed on the tracer beam to optimize alignment. This is accomplished by using the three adjustableheight legs (±.25 ) that are provided. 4

5 HIGH SENSITIVITY The minimum input signal required by the 671 Laser Wavelength Meter is as low as 1 µw. Therefore, only a small portion of the laser under test needs to be diverted from an experiment. 671 SERIES LASER WAVELENGTH METER In addition, the electronic gain of the 671 system is adjusted automatically to accommodate changes in the input signal. This is particularly useful when scanning a tunable laser over its wavelength range. Input power (µw) A Minimum Input Power A-VIS 621A-NIR 621A-IR Input power (µw) B Minimum Input Power B-VIS 621B-NIR 621B-IR 621B-MIR SIMULTANEOUS OPTICAL POWER MEASUREMENT The VIS and NIR versions of the 671 system measure total optical power in order to provide a more complete analysis of laser performance. The absolute accuracy of the power measurement is ± 15%, and is reported in mw or dbm. The IR and MIR versions are not equipped with a power detector and therefore do not provide an absolute power measurement. However, all 671 systems display a graphical representation of the relative intensity to aid with instrument alignment. 5

6 INSTRUMENT INTERFACE The 671 Laser Wavelength Meter calculates wavelength in real-time using an on-board digital signal processor. Therefore, the measured wavelength information can be reported or used in a variety of ways. Data can be transferred to a PC via USB or Ethernet and displayed using a Windows-based software program provided by Bristol Instruments. 671 SERIES LASER WAVELENGTH METER A web-based application can also be used to display wavelength measurements using a tablet or smart phone. In addition, it is easy to integrate the 671 system into an experiment for automatic wavelength reporting and control using SCPI (Standard Commands for Programmable Instruments) for custom or LabVIEW programming. DISPLAY & REPORTING The 671 Laser Wavelength Meter displays the wavelength and power measurements through several available methods. The 671 system connects directly to a PC operating with Windows 7, 8 or 1 using Bristol Instrument s intuitive NuView software. The NuView software connects directly using USB, or over a wireless network using Ethernet. Data can also be transferred to a PC using SCPI for custom or LabVIEW programming. For even more convenience, the 671 system is also accessible by the latest web browsers. This allows the user to access the 671 system using a PC, tablet, or smart phone as a convenient portable display, enabling laser wavelength information to be displayed anywhere in the laboratory. NUVIEW DISPLAY The Wavelength Screen of the NuView software displays the absolute wavelength of the laser under test. Data is reported automatically to verify laser wavelength in real time, or to allow a laser to be set precisely to an important wavelength. The VIS and NIR versions of the 671 system also display the measured optical power of the laser under test. The IR and MIR versions of the 671 system are not equipped with a power detector, and therefore do not provide an absolute power measurement. However, all 671 systems display a graphical representation of the relative intensity to aid with instrument alignment. 6

7 The NuView software features many user customizable features to tailor the measurements to specific applications. Measurement units can be expressed in wavelength (nm or µm), wavenumber (cm -1 ), or frequency (GHz or THz). Power is reported in linear (mw) or logarithmic (dbm) format. 671 SERIES LASER WAVELENGTH METER The displayed wavelength and power values can be updated with each new measurement, or display a rolling average of as many as 1 measurements. The 671 system will collect the required number of measurements before displaying the averaged value, and will update the display with each successive measurement. In addition, wavelength data can be logged to a file using a *.csv format to be used with other graphing programs. Data can be logged by number of measurements, amount of time, or continuously until the user manually stops the logging. The NuView software features an integrated Trend Screen that automatically charts a laser s wavelength over time. The Trend Screen displays a rolling graphical trace of up to 1, wavelength measurements. The Trend Screen also computes a variety of statistics over the measurement period. These include the maximum and minimum wavelength measurements, laser drift (current wavelength - start wavelength), standard deviation, and the mean. These values are reported in a table below the graph. Measurement data of a temperature-stabilized DFB laser as the cavity temperature increases by.1 C increments. The Trend Screen highlights the oscillations caused by the laser s control algorithim, as well as the overall steps in wavelength. TABLET OR SMART PHONE DISPLAY The web-based display application allows remote connection to the 671 Laser Wavelength Meter to easily provide a portable wavelength measurement display. A 671 system with a wired connection to a router can be accessed by any wireless capable computer, tablet, or smart phone connected to the same network. The display application features customizable display features similar to the NuView software. Measurement units can be expressed in wavelength (nm or µm), wavenumber (cm -1 ), or frequency (GHz or THz). Power is reported in linear (mw) or logarithmic (dbm) format. The displayed wavelength and power values can be updated with each new measurement, or a rolling average of as many as 1 measurements can be reported. The 671 system will collect the required number of measurement before displaying the averaged value, and will update the display with each successive scan. 7

Introduction to Fourier Transform Infrared Spectrometry

Introduction to Fourier Transform Infrared Spectrometry Introduction to Fourier Transform Infrared Spectrometry What is FT-IR? I N T R O D U C T I O N FT-IR stands for Fourier Transform InfraRed, the preferred method of infrared spectroscopy. In infrared spectroscopy,

More information

Experiment 5. Lasers and laser mode structure

Experiment 5. Lasers and laser mode structure Northeastern University, PHYS5318 Spring 2014, 1 1. Introduction Experiment 5. Lasers and laser mode structure The laser is a very important optical tool that has found widespread use in science and industry,

More information

Nederland België / Belgique

Nederland België / Belgique Cronus Brochure 2 Introduction Cronus: The first spectrometer and colorimeter in one The Cronus is world s first spectrocolorimeter combining a high en VIS spectrometer with a high speed XYZ colorimeter.

More information

FTIR Instrumentation

FTIR Instrumentation FTIR Instrumentation Adopted from the FTIR lab instruction by H.-N. Hsieh, New Jersey Institute of Technology: http://www-ec.njit.edu/~hsieh/ene669/ftir.html 1. IR Instrumentation Two types of instrumentation

More information

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity

More information

Measuring Laser Power and Energy Output

Measuring Laser Power and Energy Output Measuring Laser Power and Energy Output Introduction The most fundamental method of checking the performance of a laser is to measure its power or energy output. Laser output directly affects a laser s

More information

Fibre Bragg Grating Sensors An Introduction to Bragg gratings and interrogation techniques

Fibre Bragg Grating Sensors An Introduction to Bragg gratings and interrogation techniques Fibre Bragg Grating Sensors An ntroduction to Bragg gratings and interrogation techniques Dr Crispin Doyle Senior Applications Engineer, Smart Fibres Ltd. 2003 1) The Fibre Bragg Grating (FBG) There are

More information

Alignment Laser System.

Alignment Laser System. - O T 6 0 0 0 Alignment Laser System. The OT-6000. Multi -Target,Two Dimensional Alignment. Introducing the most powerful way to measure alignment at distances up to 300 feet. The OT-6000 Alignment Laser

More information

A More Efficient Way to De-shelve 137 Ba +

A More Efficient Way to De-shelve 137 Ba + A More Efficient Way to De-shelve 137 Ba + Abstract: Andrea Katz Trinity University UW REU 2010 In order to increase the efficiency and reliability of de-shelving barium ions, an infrared laser beam was

More information

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007 PUMPED Nd:YAG LASER Last Revision: August 21, 2007 QUESTION TO BE INVESTIGATED: How can an efficient atomic transition laser be constructed and characterized? INTRODUCTION: This lab exercise will allow

More information

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented User's Guide Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented Introduction Congratulations on your purchase of Extech's Laser Photo/Contact Tachometer with Non- Contact IR Thermometer,

More information

UV-Vis spectrophotometers

UV-Vis spectrophotometers UV-Vis spectrophotometers an Advanced Digital Technology EXPERIENCE SECOMAM is proud to provide the new fourthgeneration UVIKON ultraviolet-visible spectrophotometers.with more than five decades of experience

More information

Automated part positioning with the laser tracker

Automated part positioning with the laser tracker Automated part positioning with the laser tracker S. Kyle, R. Loser, D. Warren Leica Abstract Improvements and new developments for Leica's laser tracker make it suitable for measuring the relative position

More information

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431. Visit us at www.testequipmentdepot.com

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431. Visit us at www.testequipmentdepot.com Datasheet: MultiFiber Pro First MPO tester to support both Singlemode and Multimode MPO fiber testing Data centers are growing, fueled by the proliferation of media, virtualization and the need for more

More information

One Port Network Analyzer

One Port Network Analyzer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com One Port Network Analyzer 5.4GHz Impendance : 50Ω(75Ωconnectors via adapters) Test

More information

Machine Tool Inspection & Analyzer solutions

Machine Tool Inspection & Analyzer solutions Machine Tool Inspection & Analyzer solutions Introduction IBS Precision Engineering machine tool inspection series offers a range of products to provide peace of mind and control to machine operators by

More information

Impedance 50 (75 connectors via adapters)

Impedance 50 (75 connectors via adapters) VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:

More information

Components for Infrared Spectroscopy. Dispersive IR Spectroscopy

Components for Infrared Spectroscopy. Dispersive IR Spectroscopy Components for Infrared Spectroscopy Mid-IR light: 00-000 cm - (5.5 m wavelength) Sources: Blackbody emitters Globar metal oxides Nernst Glower: Silicon Carbide Detectors: Not enough energy for photoelectric

More information

Simplicity. Reliability. Performance

Simplicity. Reliability. Performance Simplicity Reliability Performance ICP Without Compromise At Teledyne Leeman Labs atomic spectroscopy is our business, our only business. We are deeply committed to providing you with technically superior

More information

ST800K-U Optical Power Meter. User Manual V1.0

ST800K-U Optical Power Meter. User Manual V1.0 User Manual V1.0 Contents 1. Summary... 1 2. Functions... 2 3. Specifications... 2 4. Layout... 4 5. Operation... 5 6. Maintenance... 7 7. Faults & Solutions... 8 8. Appendix A...9 9. Appendix B...11 10.

More information

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II BLUE SKY RESEARCH The SpectraTec II, two wavelength laser module is a highly integrated system comprised of two lasers, individual driving and temperature control electronics, wavelength combining, and

More information

Power Amplifier Gain Compression Measurements

Power Amplifier Gain Compression Measurements Technical Brief Power Amplifier Gain Compression Measurements GPIB Private Bus Sweep Out Sweep In Pulse In AC Mod Out Blank/Marker Out Blanking In Overview The 1 db gain compression of an amplifier describes

More information

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range Application Note Table of Contents 3 3 3 4 4 4 5 6 7 7 7 7 9 10 10 11 11 12 12 13 13 14 15 1. Introduction What is dynamic range?

More information

iva Cable & Antenna Analyzer

iva Cable & Antenna Analyzer iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional

More information

FIBER LASER STRAIN SENSOR DEVICE

FIBER LASER STRAIN SENSOR DEVICE FIBER LASER STRAIN SENSOR DEVICE E. Maccioni (1,2), N. Beverini (1,2), M. Morganti (1,2) F. Stefani (2,3), R. Falciai (4), C. Trono (4) (1) Dipartimento di Fisica E. Fermi Pisa (2) INFN Sez. Pisa (3) Dipartimento

More information

Lab 9: The Acousto-Optic Effect

Lab 9: The Acousto-Optic Effect Lab 9: The Acousto-Optic Effect Incoming Laser Beam Travelling Acoustic Wave (longitudinal wave) O A 1st order diffracted laser beam A 1 Introduction qb d O 2qb rarefractions compressions Refer to Appendix

More information

Example of SOP for IR Laser

Example of SOP for IR Laser Example of SOP for IR Laser Standard Operating Procedures (SOP) for Class 4 HPD semiconductor Laser Manufacturer HPD Building & Room Number EH&S 101 Model Number HPD-1/100/975 Laser Class 4 Serial Number

More information

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength

More information

HP 70950B OPTICAL SPECTRUM ANALYZER

HP 70950B OPTICAL SPECTRUM ANALYZER HP 71450B, 71451B, and 71452B Optical Spectrum Analyzers Technical Specifications Spectral Measurements from 600 to 1700 nm HP 70950B OPTICAL SPECTRUM ANALYZER OPTICAL INPUT The HP 71450B, 71451B, and

More information

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale Nano-Spectroscopy Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale Since its introduction in the early 80 s, Scanning Probe Microscopy (SPM) has quickly made nanoscale imaging an affordable

More information

DIODE PUMPED CRYSTALASER

DIODE PUMPED CRYSTALASER DIODE PUMPED CRYSTALASER Ultra-compact CW & Pulsed Turnkey Systems UV Visible to IR High Reliability High Stability High Efficiency TEMoo & SLM Low Noise Low Cost ULTRA-COMPACT DIODE-PUMPED CRYSTAL LASER

More information

High Power Programmable DC Power Supplies PVS Series

High Power Programmable DC Power Supplies PVS Series Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient

More information

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION 1 SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION By Lannes S. Purnell FLUKE CORPORATION 2 This paper shows how standard signal generators can be used as leveled sine wave sources for calibrating oscilloscopes.

More information

Agilent 8509C Lightwave Polarization Analyzer

Agilent 8509C Lightwave Polarization Analyzer Agilent 8509C Lightwave Polarization Analyzer Product Overview Highly accurate and repeatable polarization measurements of signal and components 1280 nm to 1640 nm L-Band extended wavelength option High

More information

Module 13 : Measurements on Fiber Optic Systems

Module 13 : Measurements on Fiber Optic Systems Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)

More information

Measuring of optical output and attenuation

Measuring of optical output and attenuation Measuring of optical output and attenuation THEORY Measuring of optical output is the fundamental part of measuring in optoelectronics. The importance of an optical power meter can be compared to an ammeter

More information

digital quality control fail pass at your fingertips Smart Metrology Solutions.

digital quality control fail pass at your fingertips Smart Metrology Solutions. digital quality control fail pass µphase smartgage The clever innovation in digital metrology by FISBA, which lets you smarten up your quality management and economize your production processes, yet spares

More information

MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC

MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC Measurement & Analytics Measurement made easy MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC MB3600 FT-NIR spectrometer for your industry

More information

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs Spectroscopy Biogeochemical Methods OCN 633 Rebecca Briggs Definitions of Spectrometry Defined by the method used to prepare the sample 1. Optical spectrometry Elements are converted to gaseous atoms or

More information

Radiant Dyes Laser Accessories GmbH

Radiant Dyes Laser Accessories GmbH New NarrowScan New Resonator Design Improved Sine Drive Unit Autotracking Frequency doubling, tripling and mixing Wavelength Separation Unit Frequency Stabilization Temperature Stabilization Wavelength

More information

Fiber Optic Distributed Temperature Sensor (B-DTS)

Fiber Optic Distributed Temperature Sensor (B-DTS) Fiber Optic Distributed Temperature Sensor (B-DTS) Low-cost Brillouin BOTDA scattering version For more information about our strain and temperature sensor system and related products, please visit www.ozoptics.com

More information

Kit Highlights and Key Features

Kit Highlights and Key Features AF-OLK6 Series Fiber Optic Test kit (Data Storage Kit) Product: OLK6 Series Date: Aug:2007 Rev: 01 Description The AF-OLK6 series test kits are the complete solution necessary for the installer to test,

More information

Everything you need for protection scheme testing

Everything you need for protection scheme testing Power System Simulator for Testing Protection Relays and Schemes Everything you need for protection scheme testing The is the only instrument with the high power, flexibility and software to perform full

More information

RF Network Analyzer Basics

RF Network Analyzer Basics RF Network Analyzer Basics A tutorial, information and overview about the basics of the RF Network Analyzer. What is a Network Analyzer and how to use them, to include the Scalar Network Analyzer (SNA),

More information

LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS

LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS XVII IMEKO World Congress Metrology in the 3rd Millennium June 22 27, 2003, Dubrovnik, Croatia LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS Tanfer Yandayan TUBITAK-Ulusal

More information

Synthetic Sensing: Proximity / Distance Sensors

Synthetic Sensing: Proximity / Distance Sensors Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,

More information

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Guaranteed specifications Design overview Double beam, ratio recording, double out-of-plane Littrow monochromator UV-Vis-NIR spectrophotometer (Agilent Cary

More information

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement MAS 40 Mini-Array Spectrometer light measurement Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters

More information

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD TN-100 The Fundamentals of Infrared Spectroscopy The Principles of Infrared Spectroscopy Joe Van Gompel, PhD Spectroscopy is the study of the interaction of electromagnetic radiation with matter. The electromagnetic

More information

Blackbody Radiation References INTRODUCTION

Blackbody Radiation References INTRODUCTION Blackbody Radiation References 1) R.A. Serway, R.J. Beichner: Physics for Scientists and Engineers with Modern Physics, 5 th Edition, Vol. 2, Ch.40, Saunders College Publishing (A Division of Harcourt

More information

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer CellAdvisor JD725A Dual-Port Cable and Antenna Analyzer Many modern wireless base stations are a complex system of multiple RF components, such as low-noise amplifiers (LNA), duplexers, and tower-mounted

More information

USB Smart Power Sensor

USB Smart Power Sensor 50Ω -30 dbm to +20 dbm, 1 MHz to 8000 MHz The Big Deal Low cost USB HID device compatible with 32/64 Bit operating systems Includes Measurement Application GUI (Graphical User Interface) software with

More information

E190Q Lecture 5 Autonomous Robot Navigation

E190Q Lecture 5 Autonomous Robot Navigation E190Q Lecture 5 Autonomous Robot Navigation Instructor: Chris Clark Semester: Spring 2014 1 Figures courtesy of Siegwart & Nourbakhsh Control Structures Planning Based Control Prior Knowledge Operator

More information

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions

More information

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Fundamentals of modern UV-visible spectroscopy. Presentation Materials Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms

More information

ILX Lightwave Corporation www.ilxlightwave.com

ILX Lightwave Corporation www.ilxlightwave.com # 14 Optimizing TEC Current Optimizing TEC Drive Current This Application Note discusses methods for optimizing the TEC drive current for optimum operation in heating and cooling applications. BACKGROUND

More information

FIBRE-OPTICS POWER METER INSTRUCTION MANUAL

FIBRE-OPTICS POWER METER INSTRUCTION MANUAL FIBRE-OPTICS POWER METER INSTRUCTION MANUAL FIBRE-OPTICS POWER METER ELLMAX ELECTRONICS LTD. Unit 29, Leyton Business Centre, Etloe Road, Leyton, London E10 7BT, England Tel: 020-8539 0136 Fax: 020-8539

More information

Four Wave Mixing in Closely Spaced DWDM Optical Channels

Four Wave Mixing in Closely Spaced DWDM Optical Channels 544 VOL. 1, NO. 2, AUGUST 2006 Four Wave Mixing in Closely Spaced DWDM Optical Channels Moncef Tayahi *, Sivakumar Lanka, and Banmali Rawat Advanced Photonics Research lab, Department of Electrical Engineering

More information

POLARIZATION EXTINCTION RATIO METER

POLARIZATION EXTINCTION RATIO METER POLARIZATION EXTINCTION RATIO METER Features: Measures up to 40dB extinction ratios (over specific wavelength ranges) Built in USB Communications Interface Wide wavelength range: 400 to 1000 nm for visible

More information

Calibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft

Calibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft Calibration of AFM with virtual standards; robust, versatile and accurate Richard Koops VSL Dutch Metrology Institute Delft 19-11-2015 VSL Dutch Metrology Institute VSL is the national metrology institute

More information

USB Smart Power Sensor

USB Smart Power Sensor 50Ω -30 dbm to +20 dbm, 9 khz to 4000 MHz The Big Deal Low cost USB HID device compatible with 32/64 Bit operating systems Includes Measurement Application GUI (Graphical User Interface) software with

More information

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration Relative Humidity Measurement and Calibration The widest range of humidity products from a pioneer of RH sensor development The best in Relative Humidity technology to optimize your process Whether you

More information

Optical Power Meter. Specification & User Manual

Optical Power Meter. Specification & User Manual Optical Power Meter Specification & User Manual Page 1 of 9 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4

More information

High Power and Low Coherence Fibre-optic Source for Incoherent Photonic Signal Processing

High Power and Low Coherence Fibre-optic Source for Incoherent Photonic Signal Processing High Power and Low Coherence Fibre-optic Source for Incoherent Photonic Signal Processing Y u a n L i a n d R o b e r t A. M i n a s i a n School of Electrical and Information Engineering and APCRC University

More information

PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER

PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER Lufan Zou and Taha Landolsi OZ Optics Limited, 219 Westbrook Road, Ottawa, ON, Canada, K0A 1L0 E-mail:

More information

NI USB-5681 RF Power Meter Specifications

NI USB-5681 RF Power Meter Specifications NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour

More information

Zecotek S Light Projection Network Marketing

Zecotek S Light Projection Network Marketing White Paper Zecotek Visible Fiber Laser Platform Enabling the future of laser technology Zecotek Photonics Inc. (TSX- V: ZMS; Frankfurt: W1I) www.zecotek.com is a Canadian photonics technology company

More information

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

Cabling & Test Considerations for 10 Gigabit Ethernet LAN Introduction Current communication data rates in local networks range from 10/100 megabits per second (Mbps) in Ethernet to 1 gigabit per second (Gbps) in fiber distributed data interface (FDDI) and Gigabit

More information

Light Link Series 2 LT1550. Laser Transmitter with Erbium Doped Fibre Amplifier. Description. Features

Light Link Series 2 LT1550. Laser Transmitter with Erbium Doped Fibre Amplifier. Description. Features Description The Light Link Series 2 optical transmitter model employs a high performance thermally stabilised, DFB, low-chirp, isolated laser to transmit CATV signals. Operating on a specific optical wavelength

More information

THE DETECTION OF GREENHOUSE GASES

THE DETECTION OF GREENHOUSE GASES THE DETECTION OF GREENHOUSE GASES Roy Montemarano Heath Consultants Incorporated KEYWORDS: greenhouse gas, remote detection, leak, natural gas, infrared, optical, imaging ABSTRACT Natural gas providers

More information

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION 35'th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting San Diego, December 2-4, 2003 A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION Józef Kalisz and Ryszard Szplet

More information

USB Smart Power Sensor

USB Smart Power Sensor Low Power Measurement 50Ω -45 dbm to +10 dbm, 50 to 6000 MHz The Big Deal USB HID device compatible with 32/64 Bit operating systems Includes GUI with measurement applications software, simplifying complex

More information

Advanced Solutions for Gas Monitoring

Advanced Solutions for Gas Monitoring Continuous Emissions Monitoring Stack Testing Process Monitoring Quality Control Engine Exhaust Gas Monitoring Workplace Air Quality Monitoring Combustion Research Emergency Rescue Services Advanced Solutions

More information

Application Note Noise Frequently Asked Questions

Application Note Noise Frequently Asked Questions : What is? is a random signal inherent in all physical components. It directly limits the detection and processing of all information. The common form of noise is white Gaussian due to the many random

More information

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus Please do not remove this manual from from the lab. It is available at www.cm.ph.bham.ac.uk/y2lab Optics Introduction Optical fibres are widely used for transmitting data at high speeds. In this experiment,

More information

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com

More information

Self-Mixing Laser Diode Vibrometer with Wide Dynamic Range

Self-Mixing Laser Diode Vibrometer with Wide Dynamic Range Self-Mixing Laser Diode Vibrometer with Wide Dynamic Range G. Giuliani,, S. Donati, L. Monti -, Italy Outline Conventional Laser vibrometry (LDV) Self-mixing interferometry Self-mixing vibrometer Principle:

More information

It has long been a goal to achieve higher spatial resolution in optical imaging and

It has long been a goal to achieve higher spatial resolution in optical imaging and Nano-optical Imaging using Scattering Scanning Near-field Optical Microscopy Fehmi Yasin, Advisor: Dr. Markus Raschke, Post-doc: Dr. Gregory Andreev, Graduate Student: Benjamin Pollard Department of Physics,

More information

REAL-TIME DUST AND AEROSOL MONITORING

REAL-TIME DUST AND AEROSOL MONITORING REAL-TIME DUST AND AEROSOL MONITORING THE DUSTTRAK II AND DRX AEROSOL MONITORS UNDERSTANDING, ACCELERATED REAL-TIME DUST MONITORING. ANY ENVIRONMENT. ANY APPLICATION. The DustTrak II and DRX Aerosol Monitors

More information

TereScope Management Options

TereScope Management Options Introduction TereScope Management Options MRV Communications, Inc. offers a variety of management options for the TereScope FSO product family. Whether you are a Network Service Provider, Cellular Network

More information

An Introduction to the MTG-IRS Mission

An Introduction to the MTG-IRS Mission An Introduction to the MTG-IRS Mission Stefano Gigli, EUMETSAT IRS-NWC Workshop, Eumetsat HQ, 25-0713 Summary 1. Products and Performance 2. Design Overview 3. L1 Data Organisation 2 Part 1 1. Products

More information

Long Distance Industrial Wireless Transmitters and Receivers

Long Distance Industrial Wireless Transmitters and Receivers Long Distance Industrial Wireless s and Receivers Up to 450 m (1500') Line of Sight Range UWXL Series U Thermocouple, RTD, Temperature, RH, ph, Process Voltage/ Current and Input Models U J, K, T, E, R,

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,

More information

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is

More information

Application Note Receiving HF Signals with a USRP Device Ettus Research

Application Note Receiving HF Signals with a USRP Device Ettus Research Application Note Receiving HF Signals with a USRP Device Ettus Research Introduction The electromagnetic (EM) spectrum between 3 and 30 MHz is commonly referred to as the HF band. Due to the propagation

More information

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet? Will Your Fiber Optic Cable Plant Support Gigabit Ethernet? GBE, as the name says, is Ethernet scaled up to gigabit speeds, providing a migration path from Ethernet at 10 MB/s to Fast Ethernet at 100 MB/s

More information

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706 (revised 4/21/03) NUCLEAR MAGNETIC RESONANCE Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706 Abstract This experiment studies the Nuclear Magnetic Resonance of protons

More information

iva Cable & Antenna Analyzer

iva Cable & Antenna Analyzer iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return

More information

EMX-2500 DATA SHEET FEATURES GIGABIT ETHERNET REMOTE CONTROLLER FOR PXI EXPRESS MAINFRAMES SYSTEM LEVEL FUNCTIONALITY

EMX-2500 DATA SHEET FEATURES GIGABIT ETHERNET REMOTE CONTROLLER FOR PXI EXPRESS MAINFRAMES SYSTEM LEVEL FUNCTIONALITY DATA SHEET EMX-2500 GIGABIT ETHERNET REMOTE CONTROLLER FOR PXI EXPRESS MAINFRAMES FEATURES SYSTEM LEVEL FUNCTIONALITY Industry s first gigabit Ethernet Remote controller for PXI express mainframes Up to

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

Passive Remote Sensing of Clouds from Airborne Platforms

Passive Remote Sensing of Clouds from Airborne Platforms Passive Remote Sensing of Clouds from Airborne Platforms Why airborne measurements? My instrument: the Solar Spectral Flux Radiometer (SSFR) Some spectrometry/radiometry basics How can we infer cloud properties

More information

CLASS IV THERAPY LASERS

CLASS IV THERAPY LASERS CLASS IV THERAPY LASERS 80% More than 80% of your patients can benefit from K-Laser therapy. 970 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PEAK OF WATER 905 - - - - - - - - - - - - - -

More information

Sensori ottici e laser nelle applicazioni industriali

Sensori ottici e laser nelle applicazioni industriali Sensori ottici e laser nelle applicazioni industriali Guido GIULIANI Pavia giuliani@julight.it 1 Outline Optical sensors in industry: why? Types of optical sensors optical barriers distance measurement

More information

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet. INTRODUCTION Fibre optics behave quite different to metal cables. The concept of information transmission is the same though. We need to take a "carrier" signal, identify a signal parameter we can modulate,

More information

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy UV/VIS AND UV/VIS/NIR SPECTROSCOPY A P P L I C A T I O N N O T E Introduction The availability and applications of fiber optic sampling in UV/Vis

More information

WLAN Protocol Tester PTW 70

WLAN Protocol Tester PTW 70 Data sheet Version 01.00 WLAN Protocol Tester PTW 70 November 2003 IEEE 802.11 multimode protocol tester for development, integration and verification Applications Development The PTW 70 is an indispensable

More information

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER W. Li, J. Vandewege Department of Information Technology (INTEC) University of Gent, St.Pietersnieuwstaat 41, B-9000, Gent, Belgium Abstract: Precision

More information

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

Quasi-Continuous Wave (CW) UV Laser Xcyte Series COMMERCIAL LASERS Quasi-Continuous Wave (CW) UV Laser Xcyte Series Key Features 355 nm outputs available Quasi-CW UV output Field-proven Direct-Coupled Pump (DCP ) TEM00 mode quality Light-regulated output

More information

Dual Laser InfraRed (IR) Thermometer with Color Alert

Dual Laser InfraRed (IR) Thermometer with Color Alert User Manual Dual Laser InfraRed (IR) Thermometer with Color Alert MODEL 42509 Introduction Congratulations on your purchase of the Model 42509 IR Thermometer with Color Alert. This Infrared thermometer

More information