Ducted in the Ceiling

Size: px
Start display at page:

Download "Ducted in the Ceiling"

Transcription

1 Ducted in the Ceiling 54 More information on controls and options on pages

2 DUCTED IN THE CEILING Hitachi s Ducted range can be positioned discreetly in the ceiling. The units are ideal for hotel bedrooms, banks and small offices where very low noise levels are needed. COP 3.61 MONOZONE Standard pressure RAD RPA pages 58 and 59 COP 3.77 MONOZONE High pressure RAD PPA pages 58 and 59 COP 3.59 UTOPIA ES RPI 5 6 FSN4E / RPI 8 10 FSN3E pages 60 and 61 COP 4.03 UTOPIA IVX COMFORT RPI 4 6 FSN4E / RPI 8 10 FSN3E pages 62 and 63 COP 4.23 UTOPIA IVX PREMIUM RPI 2 6 FSN4E / RPI 8 10 FSN3E pages 64 and 65 COP 3.80 UTOPIA IVX CENTRIFUGAL RPI 4 6 FSN4E / RPI 8 10 FSN3E pages 66 and 67 55

3 Ducted in the Ceiling UTOPIA ES RPI 36FSN4E PC ARF RAS 3HVRNS3 RPI 810FSN3E PC ART RAS 46H(V)RNS3E RAS 810HRNSE Indoor units Nominal cooling capacities 7.1kW to 25.0kW Nominal heating capacities 8.0kW to 28.0kW Ultra low power consumption Ultra Quiet from 29 db(a) 4 speed, 3 static pressure levels, including zero pressure setting Possible to supply fresh air : Econofresh see pages Remote controllers Advanced PCARF wired LED controller (inc. 7day time clock) 5 time ranges with different temperatures (reduced, weekly, holiday etc) Service menu and optional function menus, add your contact details to be shown when there is an error Standard PCART wired remote controller (inc. 7day time clock) 4 prograable weekly schedules Service menu, optional function menu and fault diagnostic Alternative option: infrared or simplified remote control see pages Outdoor units Compact design single fan (up to 6HP) SCOP of up to 3.83 A rating and SEER of up to 4.62 B rating Available in single phase and three phase RPI 56FSN4E 60 More information on controls and options on pages

4 UTOPIA ES Ducted in the Ceiling INDOOR UNITS RPI 3.0FSN4E RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E RPI 8.0FSN3E RPI 10.0FSN3E Nominal Cooling Capacity (min max) (1) kw 7.1 ( ) 10 ( ) 12.5 ( ) 14.0 ( ) ( ) ( ) Nominal Heating Capacity (min max) (2) kw 8.0 ( ) 11.2 ( ) 14.0 ( ) 16.0 ( ) ( ) ( ) UK Cooling Capacity (sensible) (3) kw 7.4 (6.0) 10.3 (7.9) 12.7 (9.1) 15.2 (10.5) 20.1 (15.5) 24.9 (17.9) Seasonal Efficiency SEER (4) Energy Efficiency Class 4.62 B 4.62 B na * na * na * na * Seasonal Efficiency SCOP (4) (Average Climate) Energy Efficiency Class 3.81 A 3.83 A na * na * na * na * Nominal Load Efficiency EER / COP (5) Energy Class (Cool/Heat) 2.81 / 3.54 C / B 3.4 / 3.59 B / A 2.84 / 3.27 C / C 2.67 / 3.18 D / C 2.46 / 3.00 E / D 2.32 / 2.97 F / D Noise Level (sound pressure) (L / M / H) (6) db(a) 29/31/31 32/35/37 33/35/38 33/36/39 51/54/54 52/55/55 Noise level (sound power) (8 ) db(a) Air flow cooling mode (L / M / H) m 3 /h 960/1140/ /1680/ /1920/ /1980/ /3960/ / 4500 / 4500 Static Pressure Nom. (min ~ max) Pa 30 (0 125) 45 (0 120) 50 (0 140) 50 (0 140) Dimensions (H x W x D) 275x1084x x1474x x1474x x1474x x 1592 x x 1592 x 600 Weight kg Included Condensate Pump yes yes yes yes no no Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ32 φ32 φ32 φ32 φ25 φ25 3/8 / 3/ / /8 / 7/ / 22.2 Power Input w Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A Remote Controller PC ART (PC ARF infrared and simplified model optional) OUTDOOR UNITS RAS 3HVRNS3 RAS 4H(V)RNS3E RAS 5H(V)RNS2E RAS 6H(V)RNS2E RAS 8HRNSE RAS 10HRNSE Power supply 230V / 1Ph / 50Hz (230V / 1Ph / 50Hz) 400V / 3Ph / 50Hz 400V / 3Ph / 50Hz Noise level cooling (sound pressure) (night mode) (7) db(a) 48 (46) 50 (48) 52 (50) 55 (53) 53 (51) 60 (56) Noise level heating (sound pressure) (7) db(a) Noise level (sound power) (8) db(a) Air flow (Cooling / Heating) m 3 /h Dimensions (H x W x D) 600x792x x950x x950x x950x x950x x950x370 Weight kg Piping diameter (Liquid / Gas) 3/8 / 11/ / /2 / 11/ / Minimum Piping Length m Maximum Piping Length / Height Difference m 50 / / / / / / 30 Current Quantity of Refrigerant kg Chargeless / Additional Refrigerant Charge m / g/m 20 / / / / / / (120) Recoended fuse size 1Ph/3Ph A 25 32/16 32/16 32/16 /32 /32 Starting current (1Ph/3Ph) A <10 <10 <10 <10 <10 <10 Running current (cooling / heating) 1Ph (3Ph) A 10.0 / 8.8 (/) 11.3 / 11.3 (4.1 / 4.1) 18.4 / 18.5 (6.5 / 6.6) 24.6 / 23.8 (8.7 / 8.4) / (10.7 / 9.9) / (14.6 / 13.5) Interconnecting Cables No. LNE + 2 core screened Working Range (cooling / heating) C 5ºC~43(db)ºC / 20(wb)ºC~15(wb)ºC Refrigerant / GWP R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 Compressor type Scroll Rotary Scroll Scroll Scroll Scroll System price includes PCART wired remote controller. (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) Ambient 35 C (2) Nominal Heating: Internal temperature 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Data calculated in accordance to pren14825 and the Coission Counication 2012/C 172/01 (5) Nominal load efficiency (Cooling 35 C/27 C, Heating 7 C/20 C) (6) Sound pressure level is measured at 1.5m below the unit (Measured in an anechoic chamber) (7) Sound pressure level is measured at 1.0m from the unit front surface and 1.5m from floor level (Measured in an anechoic chamber) (8) Sound power level is the Aweighted sound power level [db(a)] measured at standard rated conditions for the «cooling» mode operation in accordance to EN

5 Ducted in the Ceiling UTOPIA IVX COMFORT RPI 36FSN4E PC ARF RAS 3HVNC1 RPI 810FSN3E Indoor units Possible to supply fresh air : Econofresh see pages Low consumption motor 4 speed, 3 static pressure levels, including zero pressure for blowing onto the grill. PC ART Remote controllers Advanced PCARF wired LED controller (inc. 7day time clock) 5 time ranges with different temperatures (reduced, weekly, holiday etc) Service menu and optional function menus, add your contact details to be shown when there is an error Standard PCART wired remote controller (inc. 7day time clock) 4 prograable weekly schedules Service menu, optional function menu and fault diagnostic Alternative option: infrared or simplified remote control see pages RAS 456H(V)NC1E Outdoor units RAS 810HNCE Capacities from 3.2kW to 35kW Compact design single fan (up to 6HP) Multi split applications possible SCOP of up to 4.31 A rating and SEER of up to 5.84 A+ rating Available in single phase and three phase RPI 36FSN4E 62 More information on controls and options on pages

6 UTOPIA IVX COMFORT Ducted in the Ceiling INDOOR UNITS RPI 3.0FSN4E RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E RPI 8.0FSN3E RPI 10.0FSN3E Nominal Cooling Capacity (min max) (1) kw 7.1 ( ) 10 ( ) 12.5 ( ) 14.0 ( ) ( ) ( ) Nominal Heating Capacity (min max) (2) kw 8.0 ( ) 11.2 ( ) 14.0 ( ) 16.0 ( ) ( ) ( ) UK Cooling Capacity (sensible) (3) kw 7.7 (6.2) 10.6 (8.2) 13.2 (9.5) 15.6 (10.8) 21.1 (16.2) 26.1 (18.8) Seasonal Efficiency SEER (4) Energy Efficiency Class 4.97 B 5.38 A Seasonal Efficiency SCOP (4) (Average Climate) Energy Efficiency Class 3.80 A 4.01 A+ Nominal Load Efficiency EER / COP (5) Energy Class (Cool/Heat) 2.81 / 3.54 C / B 3.10 / 4.03 B / A 3.18 / 3.54 A / B 3.08 / 3.37 B / C 2.84 / 3.07 C / D 2.73 / 3.04 D / D Noise Level (sound pressure) (L / M / H) (6) (SP00) db(a) 29/31/31 32/35/37 33/35/38 33/36/39 51/54/54 52/55/55 Noise level (sound power) (8) (SP00) db(a) Air flow cooling mode (L / M / H) m 3 /h 960/1140/ /1680/ /1920/ /1980/ /3960/ / 4500 / 4500 Static Pressure Nom. (min ~ max) Pa 30 (0 125) 45 (0 120) 50 (0 140) 50 (0 140) Dimensions (H x W x D) 275x1084x x1474x x1474x x1474x x 1592 x x 1592 x 600 Weight kg Included Condensate Pump yes yes yes yes no no Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ32 φ32 φ32 φ32 φ25 φ25 3/8 / 7/ / 22.2 Power Input w Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A Remote Controller PC ART (PCARF, infrared and simplified model optional) OUTDOOR UNITS RAS 3HVNC1 RAS 4H(V)NC1E RAS 5H(V)NC1E RAS 6H(V)NC1E RAS 8HNCE RAS 10HNCE Power supply 230V / 1Ph / 50Hz (230V / 1Ph / 50Hz) 400V / 3Ph / 50Hz 400V / 3Ph / 50Hz Noise level cooling (sound pressure) (night mode) (7) db(a) 48 (46) 52 (50) 52 (50) 55 (53) 57 (55) 58 (56) Noise level heating (sound pressure) (7) db(a) Noise level (sound power) (8) db(a) Air flow (Cooling / Heating) m 3 /h Dimensions (H x W x D) 600 x 792 x x 950 x x 950 x x 950 x x 950 x x 950 x 370 Weight kg Piping diameter (Liquid / Gas) 3/8 / 11/ / /2 / 11/ / Minimum Piping Length m Maximum Piping Length / Height Difference m 50 / / / / / / 30 Current Quantity of Refrigerant kg Chargeless / Additional Refrigerant Charge m / g/m 20 / / / / / Calculate 30 / Calculate Recoended fuse size 1Ph/3Ph A 20/ 32/25 32/16 32/16 /32 /32 Starting current (1Ph/3Ph) A <10 <10 <10 <10 <10 <10 Running current (cooling / heating) 1Ph (3Ph) A 9.4/8.3 (/) 11.2/10.1 (4.1/3.7) 15.5/15.1 (5.7/5.5) 18.1/19.0 (6.6/6.9) / (9.1/9.0) / (12.9/12.0) Interconnecting Cables No. LNE + 2 core screened Working Range (cooling / heating) C 5ºC~46(db)ºC / 20(wb)ºC~15(wb)ºC Refrigerant / GWP R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 Compressor type Scroll Scroll Scroll Scroll Scroll Scroll System price includes PCART wired remote controller. (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) Ambient 35 C (2) Nominal Heating: Internal temperature 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Data calculated in accordance to pren14825 and the Coission Counication 2012/C 172/01 (5) Nominal load efficiency (Cooling 35 C/27 C, Heating 7 C/20 C) (6) Sound pressure level is measured at 1.5m below the unit (Measured in an anechoic chamber) (7) Sound pressure level is measured at 1.0m from the unit front surface and 1.5m from floor level (Measured in an anechoic chamber) (8) Sound power level is the Aweighted sound power level [db(a)] measured at standard rated conditions for the «cooling» mode operation in accordance to EN

7 Ducted in the Ceiling UTOPIA IVX PREMIUM RPI 26FSN4E PC ARF RAS 22.5HVNP1 RPI 810FSN3E Indoor units Nominal cooling capacities 5.0kW to 25.0kW Nominal heating capacities 5.6kW to 28.0kW Possible to supply fresh air: Econofresh see pages Low consumption motor 4 speed, 3 static pressure levels, including zero pressure setting Easily accessible filters. PC ART Remote controllers Advanced PCARF wired LED controller (inc. 7day time clock) 5 time ranges with different temperatures (reduced, weekly, holiday etc) Service menu and optional function menus, add your contact details to be shown when there is an error Standard PCART wired remote controller (inc. 7day time clock) 4 prograable weekly schedules Service menu, optional function menu and fault diagnostic Alternative option: infrared or simplified remote control see pages RAS 3HVNP1E Outdoor units Compact design single fan (up to 6HP) RAS 410H(V)NP1E Fully ErP compliant with A++ seasonal efficiency Available in single phase and three phase. RPI 26FSN4E 64 More information on controls and options on pages

8 UTOPIA IVX PREMIUM Ducted in the Ceiling INDOOR UNITS RPI 2.0FSN4E RPI 2.5FSN4E RPI 3.0FSN4E RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E RPI 8.0FSN3E RPI 10.0FSN3E Nominal Cooling Capacity (min max) (1) kw 5.0 ( ) 5.6 ( ) 7.1 ( ) 10 ( ) 12.5 ( ) 14.0 ( ) 20.0 ( ) 25.0 ( ) Nominal Heating Capacity (min max) (2) kw 5.6 ( ) 6.3 ( ) 8.0 ( ) 11.2 ( ) 14.0 ( ) 16.0 ( ) 22.4 ( ) 28.0 ( ) UK Cooling Capacity (sensible) (3) kw 5.3 (4.7) 5.9 (5.1) 7.7 (6.2) 10.6 (8.2) 13.2 (9.5) 15.7 (10.8) 21.1 (16.2) 26.1 (18.8) Seasonal Efficiency SEER (4) Energy Efficiency Class 5.83 A A A A++ Seasonal Efficiency SCOP (4) (Average Climate) Energy Efficiency Class 4.01 A A A A+ Nominal Load Efficiency EER / COP (5) Energy Class (Cool/Heat) 3.54 / 3.73 A / A 3.49 / 3.81 A / A 3.5 / 3.95 A / A 3.92 / 4.23 A / A 3.42/3.92 A / A 3.07 / 3.64 B / A 3.05 / 3.25 B / C 2.93 / 3.22 C / C Noise Level (sound pressure) (L / M / H) (6) (SP00) db(a) 27/29/29 28/30/30 29/31/31 32/35/37 33/35/38 33/36/39 51/54/54 25/55/55 Noise level (sound power) (8) (SP00) db(a) Air flow cooling mode (L / M / H) m 3 /h 600/750 / /960/ /1140/ /1680/ /1920/ /1980/ /3960/ /4500/4500 Static Pressure Nom. (min ~ max) Pa 30 (0~120) 30 (0~125) 30 (0 125) 45 (0 120) 50 (0 140) 50 (0 140) Dimensions (H x W x D) 275 x 1084 x x1084x x 1084 x x 1474 x x 1474 x x 1474 x x 1592 x x 1592 x 600 Weight kg Included Condensate Pump yes no Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ32 φ32 φ32 φ32 φ32 φ32 φ25 φ25 1/4 / 5/8 3/8 / 3/ / / Power Input w Power supply 230V / 1Ph / 50Hz Recoended fuse size A 5 10 Remote Controller PC ART (PCARF, infrared and simplified model optional) 3/8 / 7/ / 22.2 OUTDOOR UNITS RAS 2HVNP1 RAS 2.5HVNP1 RAS 3HVNP1 RAS 4H(V)NP1E RAS 5H(V)NP1E RAS 6H(V)NP1E RAS 8HNPE RAS 10HNPE Power supply 230V / 1Ph / 50Hz (230V / 1Ph / 50Hz) 230V / 1Ph / 400V / 3Ph / 50Hz 50Hz 400V / 3Ph / 50Hz Noise level cooling (sound pressure) (night mode) (7) db(a) 44 (42) 45 (43) 46 (42) 47 (43) 48 (44) 48 (45) 57 (55) 58 (56) Noise level heating (sound pressure) (7) db(a) Noise level (sound power) (8) db(a) Air flow (Cooling / Heating) m 3 /h Dimensions (H x W x D) 600 x 792 x x 792 x x 950 x x 950 x x 950 x x 950 x x 950 x x 950 x 370 Weight kg Piping diameter (Liquid / Gas) 6.35 / / /8 / 11/ / /2 / 11/ / Minimum Piping Length m Maximum Piping Length / Height Difference m 50 / / / / / / / / 30 Current Quantity of Refrigerant kg Chargeless / Additional Refrigerant Charge m / g/m 30 / / / / / / / Calculate 30 / Calculate Recoended fuse size 1Ph/3Ph A 16/ 20/ 20/ 32/16 32/16 32/16 /32 /32 Starting current (1Ph/3Ph) A <10 <10 <10 <10 <10 <10 <10 <10 Running current (cooling / heating) 1Ph (3Ph) A 5.1/4.9 (/) 5.4/5.7 (/) 6.4/6.7 (/) 8.7/8.9 (3.2/3.2) 13.7/12.8 (5.0/4.7) 17.3/15.9 (6.3/5.8) 8.6/ /11.3 Interconnecting Cables No. LNE + 2 core screened Working Range (cooling / heating) C 5ºC~46(db)ºC / 20(wb)ºC~15(wb)ºC Refrigerant / GWP R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 Compressor type Scroll Scroll Rotary Scroll Scroll Scroll Scroll Scroll System price includes PCART wired remote controller. (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) Ambient 35 C (2) Nominal Heating: Internal temperature 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Data calculated in accordance to pren14825 and the Coission Counication 2012/C 172/01 (5) Nominal load efficiency (Cooling 35 C/27 C, Heating 7 C/20 C) (6) Sound pressure level is measured at 1.5m below the unit (Measured in an anechoic chamber) (7) Sound pressure level is measured at 1.0m from the unit front surface and 1.5m from floor level (Measured in an anechoic chamber) (8) Sound power level is the Aweighted sound power level [db(a)] measured at standard rated conditions for the «cooling» mode operation in accordance to EN

9 Ducted in the Ceiling UTOPIA IVX CENTRIFUGAL NEW RPI 5FSN4E PC ARF RPI 10FSN3E Indoor units Nominal cooling capacities 10.0kW to 25.0kW Nominal heating capacities 11.2kW to 28.0kW Possible to supply fresh air: Econofresh see pages Low consumption motor 4 speed, 3 static pressure levels, including zero pressure setting Easily accessible filters. PC ART Remote controllers Advanced PCARF wired LED controller (inc. 7day time clock) 5 time ranges with different temperatures (reduced, weekly, holiday etc) Service menu and optional function menus, add your contact details to be shown when there is an error Standard PCART wired remote controller (inc. 7day time clock) 4 prograable weekly schedules Service menu, optional function menu and fault diagnostic Alternative option: infrared or simplified remote control see pages RASC 410HNPE Outdoor units Only Utopia IVX centrifugal on the market Installed indoors with fieldsupplied ductwork ideal where external installation space is limited or planning restrictions apply Low temperature operation as standard Flexible inlet air and outlet air option for easy installation (excludes 5HP) Only 43cm high (5HP only) RPI 5FSN4E 66 More information on controls and options on pages

10 UTOPIA IVX CENTRIFUGAL Ducted in the Ceiling INDOOR UNITS RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E RPI 8.0FSN3E RPI 10.0FSN3E Nominal Cooling Capacity (min max) (1) kw 10 ( ) 12.5 ( ) 14.0 ( ) ( ) ( ) Nominal Heating Capacity (min max) (2) kw 11.2 ( ) 14.0 ( ) 16.0 ( ) ( ) ( ) UK Cooling Capacity (sensible) (3) kw 10.3 (7.9) 12.7 (9.1) 15.2 (10.5) 20.1 (15.5) 24.9 (17.9) Nominal Load Efficiency EER / COP (4) Energy Class (Cool/Heat) 3.35 / 3.8 A / A 3.14 / 3.4 B / C 2.75 / 2.7 D / E 2.7 / 3.2 D / D 2.66 / 3.05 D / D Noise Level (sound pressure) (L / M / H) (5) db(a) 32/35/37 33/35/38 33/36/39 51/54/54 52/55/55 Noise level (sound power) (6) db(a) Air flow cooling mode (L / M / H) m 3 /h 1500/1680/ /1920/ /1980/ /3960/ / 4500 / 4500 Static Pressure Nom. (min ~ max) Pa 45 (0 120) 50 (0 140) 50 (0 140) Dimensions (H x W x D) 275x1474x x1474x x1474x x 1592 x x 1592 x 600 Weight kg Included Condensate Pump yes yes yes no no Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ32 φ32 φ32 φ25 φ25 3/8 / 3/ / Power Input w Power supply 230V / 1Ph / 50Hz Recoended fuse size A Remote Controller PC ART (PCARF, infrared and simplified model optional) 3/8 / 7/ / 22.2 OUTDOOR UNITS RASC 4HNPE RASC 5HNPE RASC 6HNPE RASC 8HNPE RASC 10HNPE Power supply 400V / 3Ph / 50Hz Noise level cooling (sound pressure) (night mode )(5) db(a) 52 (48) 52 (48) 53 (49) 55 (51) 56 (52) Noise level heating (sound pressure) (5) db(a) Noise level (sound power) (6) db(a) Air flow (Cooling / Heating) m 3 /h Maximum External Static Pressure Pa Dimensions (H x W x D) 555 x 1415 x x 1415 x x 1415 x x 1850 x x 1850 x 1360 Weight kg Piping diameter (Liquid / Gas) 1/2 / 1 1/ / Minimum Piping Length m Maximum Piping Length / Height Difference m 75 / / / / / 30 Current Quantity of Refrigerant kg Chargeless / Additional Refrigerant Charge m / g/m 30 / / / / Calculate 30 / Calculate Drain Diameter (ext) φ30 φ30 φ30 φ30 φ30 Recoended fuse size A Starting current A <10 <10 <10 <10 <10 Running current (cooling / heating) A 4.8/ / / / /13.7 Interconnecting Cables No. LNE + 2 core screened Working Range (cooling / heating) C 5ºC~46(db)ºC / 20(wb)ºC~15(wb)ºC Refrigerant / GWP R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 Compressor type Scroll Scroll Scroll Scroll Scroll System price includes PCART wired remote controller. (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) Ambient 35 C (2) Nominal Heating: Internal temperature 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Nominal load efficiency (Cooling 35 C/27 C, Heating 7 C/20 C) (5) Sound pressure level is measured at 1.5m below the unit (Measured in an anechoic chamber) (6) Sound power level is the Aweighted sound power level [db(a)] measured at standard rated conditions for the «cooling» mode operation in accordance to EN

11 Indoor Units UTOPIA IVX DUCTED IN THE CEILING RPIM 0.8FSN4E(DU) RPIM 1.0FSN4E(DU) RPIM 1.5(1.3)FSN4E(DU) RPIM 1.5FSN4E RPI 0.8FSN4E RPI 1.0FSN4E Nominal Cooling Capacity (1) kw Nominal Heating Capacity (2) kw UK Cooling Capacity (sensible) (3) kw 2.1 (1.7) 2.6 ( (2.3) 3.7 (2.6) 2.1 (1.7) 2.6 (2.1 Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 27/29/29 27/29/29 28/30/30 28/30/30 29/31/33 29/31/33 Noise level (sound power) (5) (SP00) db(a) Air flow cooling mode (L / M / H) (SP00) m 3 /h 330/408/ /408/ / 540 / / 540 / /432/ /432/480 Static Pressure Nom. (min ~ max) Pa 32 (0~50) 32 (0~50) 27 (0~58) 27 (0~58) 32 (0~50) 32 (0~50) Dimensions (H x W x D) 275x702x x702x x702x x702x x 1084 x x 1084 x 600 Weight kg Included Condensate Pump (DU model only) yes yes yes yes yes yes Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ25 φ25 φ25 φ25 φ25 φ / / / / / / Power Input W Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A RPI 1.5(1.3)FSN4E RPI 1.5FSN4E RPI 2.0(1.8)FSN4E RPI 2.0FSN4E RPI 2.5(2.3)FSN4E RPI 2.5FSN4E Nominal Cooling Capacity (1) kw Nominal Heating Capacity (2) kw UK Cooling Capacity (sensible) (3) kw 3.2 (2.3) 3.7 (2.7) 4.3 (3.3) 5.3 (4.0) 5.5 (4.1) 5.9 (4.5) Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 29/31/34 29/31/34 27/29/29 27/29/29 28/30/30 28/30/30 Noise level (sound power) (5) (SP00) db(a) Air flow cooling mode (L / M / H) (SP00) m 3 /h 480/540/ /540/ /900/ /900/ /1020/ /1020/1140 Static Pressure Nom. (min ~ max) Pa 27 (0~50) 27 (0~50) 30 (0 120) 30 (0 120) 30 (0 140) 30 (0 140) Dimensions (H x W x D) 197x1084x x1084x x1084x x1084x x1084x x1084x600 Weight kg Included Condensate Pump (DU model only) yes yes yes yes yes yes Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ25 φ32 φ32 φ32 φ32 φ32 1/4 / 5/8 1/4 / 5/ / / / / Power Input W Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A RPI 3.0FSN4E RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E RPI 8.0FSN3E RPI 10.0FSN3E Nominal Cooling Capacity (1) kw Nominal Heating Capacity (2) kw UK Cooling Capacity (sensible) (3) kw 7.7 (5.8) 10.6 (7.7) 13.2 (9.5) 15.7 (11.3) 21.1 (16.2) 26.1 (20.6) Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 29/31/31 25/28/30 28/32/35 29/33/36 51/54/54 25/55/55 Noise level (sound power) (5) (SP00) db(a) Air flow cooling mode (L / M / H) (SP00) m 3 /h 1020/1200/ /1680/ /1920/ /1980/ /3960/ /4500/4500 Static Pressure Nom. (min ~ max) Pa 30 (0 150) 45 (0 110) 50 (0 140) 50 (0 150) 180/220/ /220/220 Dimensions (H x W x D) 275x1084x x1474x x1474x x1474x x 1592x x 1592x600 Weight kg Included Condensate Pump (DU model only) yes yes yes yes no no Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ25 φ32 φ32 φ32 φ25 φ25 3/8 / 3/4 3/8 / 7/ / / 22.2 Power Input W Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A (1) Cooling: Internal ambient 27 C db (19 C wb) Ambient 35 C (2) Heating: Internal ambient 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Sound pressure level measured at 1.5 m below the unit with 1m of return air ducting and 2m of discharge ducting (without ceiling under the unit) (5) Sound power level is the Aweighted sound power level [db(a)] measured at standard rated conditions for the «cooling» mode operation in accordance to EN More information on controls and options on pages

12 Set Free DUCTED IN THE CEILING LOW HEIGHT PC ARF New multifunction graphical remote control (see page 262) DC Inverter fan motors deliver up to 40% reduction in energy consumption compared to previous model Very low noise Unit height less than 200, particularly suitable for lowered ceilings Adjustable return air configuration Automatic drainage pump eliminates condensation build up. RPI 0.6~1.5FSN4E (Low height) DUCTED IN THE CEILING (LOW HEIGHT) RPI 0.6FSN4E RPI 0.8FSN4E RPI 1.0FSN4E RPI 1.5(1.3)FSN4E RPI 1.5FSN4E Nominal Cooling Capacity (1) kw Nominal Heating Capacity (2) kw UK Cooling Capacity (sensible) (3) kw 1.5 (1.2) 2.1 (1.7) 2.6 (2.1) 3.4 (2.4) 3.9 (2.8) Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 27/30/32 29/31/33 29/31/33 29/31/34 29/31/34 Noise level (sound power) (SP00) db(a) Air flow cooling mode (L / M / H) (SP00) m 3 /h 330/372/ /432/ /432/ /540/ /540/600 Static Pressure Nom. (min ~ max) Pa 20 (0~35) 32 (0~50) 32 (0~50) 27 (0~50) 27 (0~50) Dimensions (H x W x D) 197 x 1084 x x 1084 x x 1084 x x 1084 x x 1084 x 600 Weight kg Included Condensate Pump (DU model only) yes yes yes yes yes Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ25 φ25 φ25 φ25 φ / / / / / Power Input W Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A (1) Cooling: Internal ambient 27 C db (19 C wb) Ambient 35 C (2) Heating: Internal ambient 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Sound pressure level measured at 1.5 metres below the unit (measured in anechoic room) 197

13 Set Free DUCTED IN THE CEILING STANDARD PC ARF New multifunction graphical remote control (see page 262) Adjustable static pressure depending on installation requirements Static pressure adjustment via remote controller RPI 2~6FSN4E (Standard) Builtin drain pump (excludes RPIFSN3E models) DUCTED IN THE CEILING (STANDARD) RPI 2.0(1.8)FSN4E RPI 2.0FSN4E RPI 2.5(2.3)FSN4E RPI 2.5FSN4E RPI 3.0FSN4E RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E Nominal Cooling Capacity (1) kw Nominal Heating Capacity (2) kw UK Cooling Capacity (sensible) (3) kw 4.5 (3.4) 5.2 ( (4.7) 6.4 (4.9) 7.5 (5.6) 10.5 (7.7) 12.7 (9.1) 14.8 (10.7 Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 27/29/29 27/29/29 28/30/30 28/30/30 29/31/31 25/28/30 28/32/35 29/33/36 Noise level (sound power) (SP00) db(a) Air flow cooling mode (L / M / H) (SP00) m 3 /h 780/900/ /1020/ /1200/ /1680/ /1920/ /1980/2160 Static Pressure Nom. (min ~ max) Pa 30 (0 120) 30 (0 140) 30 (0 150) 45 (0 110) 50 (0 140) 50 (0 150) Dimensions (H x W x D) 275 x 1084 x x 1474 x 600 Weight kg Included Condensate Pump (DU model only) yes yes yes yes yes yes yes yes Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ32 φ32 φ32 φ32 φ32 φ32 φ32 φ32 1/4 / 5/8 1/4 / 5/ / / Power Input W Power supply 230V / 1Ph / 50Hz Recoended fuse size A (1) Cooling: Internal ambient 27 C db (19 C wb) Ambient 35 C (2) Heating: Internal ambient 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Sound pressure level measured at 1.5 metres below the unit (measured in anechoic room) 198 More information on controls and options on pages

14 Set Free DUCTED IN THE CEILING LARGE CAPACITY PC ARF New multifunction graphical remote control (see page 262) Adjustable static pressure depending on installation requirements Static pressure adjustment via remote controller RPI 8~10FSN3E (Large capacity) Builtin drain pump (excludes RPIFSN3E models) DUCTED IN THE CEILING (LARGE CAPACITY) RPI 8.0FSN3E RPI 10.0FSN3E RPI 16.0FSN3PE RPI 20.0FSN3PE Nominal Cooling Capacity (1) kw Nominal Heating Capacity (2) kw UK Cooling Capacity (sensible) (3) kw 18.4 (14.21) 22.9 (18.1) 36.8 (28.4) 45.8 (36.2) Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 51/54/54 52/55/55 53//56 54//57 Noise level (sound power) (SP00) db(a) Air flow cooling mode (L / M / H) (SP00) m 3 /h 3600/3960/ /4500/ // //9000 Static Pressure Nom. (min ~ max) Pa 180/220/ /220/ // //220 Dimensions (H x W x D) 432 x 1592 x x 1592 x x 1592 x x 1592 x 600 Weight kg Included Condensate Pump (DU model only) no no no no Condensate Pump Lift Drain Diameter (ext) φ25 φ25 2 x φ25 2 x φ25 3/8 / 3/4 3/8 / 7/8 2 x 3/8 / 3/4 2 x 3/8 / 7/ / / x 9.53 / x 9.53 / 22.2 Power Input W x x 1065 Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A (1) Cooling: Internal ambient 27 C db (19 C wb) Ambient 35 C (2) Heating: Internal ambient 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Sound pressure level measured at 1.5 metres below the unit (measured in anechoic room) 199

15 Ventilation ECONOFRESH Functions EF 4,5 & 6NE The Econofresh can be attached to the RPI size 4, 5 & 6 ducted units. Fresh and recycled air is controlled using a series of dampers It can also be connected to a CO2 sensor to ensure the air quality or use of a enthalpy probe The Econofresh kit can provide up to 100% fresh air and has the ability to provide free cooling when the outdoor temperature is below the indoor setting temperature Used in conjunction with Hitachi s RPI In the Ceiling unit Maintains the correct room temperature and provides fresh air, but also provides natural cooling therefore increasing energy savings. RAS 5 H(V)NP1E Outdoor units New DC inverter compressor for improved lowspeed and partload seasonal performance SCOP of up to 4.65 A+ rating and SEER of up to 6.82 A++ rating. Individual control of multiple indoor units in each zone Adjust temperature settings according to occupancy and external environmental conditions to save on energy. Reduced number of outdoor units and less pipework required. Cold draught prevention, frost protection and low noise as standard. RPI 4, 5 & 6FSN4E Indoor units Ultra low energy consumption Ultra quiet up to 27 db(a) 3 fan speeds 3 static pressure settings All models compatible with the UTOPIA IVX and SET FREE ranges Easily accessible filters. EF 5NE 208 More information on controls and options on pages

16 Econofresh DUCTED INDOOR UNITS RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E Nominal Cooling Capacity (min max) (1) kw 10 ( ) 12.5 ( ) 14.0 ( ) Nominal Heating Capacity (min max) (2) kw 11.2 ( ) 14.0 ( ) 16.0 ( ) UK Cooling Capacity (sensible) (3) kw 10.6 (8.2) 13.2 (9.5) 15.7 (10.8) Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 25/28/30 28/32/35 29/33/36 Noise level (sound power) (SP00) db(a) Air flow cooling mode (L / M / H) m 3 /h 1500/1680/ /1920/ /1980/2160 Static Pressure Nom. (min ~ max) Pa 45 (0 110) 50 (0 140) 50 (0 150) Dimensions (H x W x D) 275x1474x x1474x x1474x600 Weight kg Included Condensate Pump yes yes yes Drain Diameter (ext) φ32 φ32 φ32 Power Input w Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) Ambient 35 C (2) Nominal Heating: Internal temperature 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Sound pressure level is measured at 1.5m below the unit (Measured in an anechoic chamber). ECONOFRESH KIT EF456NE Dimensions H x L x W 254x310x1350 Weight kg 12.5 Power Supply Fed From Indoor Unit Interconnecting Cables Supplied Remote Controller Type via Indoor Unit The Econofresh EF456NE is compatible with ES, IVX and Set Free Systems Data in table above is when used with IVX Premium. OPERATING PRINCIPLE 209

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal

Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal Utopia Split Systems Models Utopia ES (7.1-14 kw) Utopia IVX (7.1-30 kw) Utopia DC Inverter (5-14 kw) Utopia Fixed Speed (6.3-12.5 kw) Utopia Centrifugal (12.5-25 kw) Contents Company Profile 4 Utopia

More information

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,

More information

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW utopia DC Inverter 7kW-14kW G8 5kW-25kW Split Systems Contents Company profile 4 Product range overview 6 Features and benefits 8 DC Inverter 12 Utopia G8 24 Utopia centrifugal 40 Total heat exchanger

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world s leading technology companies, MITSUBISHI ELECTRIC

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Inverter Air Conditioning for Light Commercial Use

Inverter Air Conditioning for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE

More information

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4) room air conditioners Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4) Contents Company profile 4 Product range overview 6 Standards and quality certificates 8

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Replacement VRV Cost effective upgrade for R-22 s High efficiency Possibility to increase capacity Limited and planned downtime Limited and phased investment cost www.daikin.eu

More information

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4. AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice

More information

M Series. Room Air Conditioning

M Series. Room Air Conditioning M Series Room Air Conditioning The Adaptable M Series Range Available in a variety of options, our M Series range fits in wherever it s needed. Indoor units can be wall or floor mounted. The full M series

More information

YUTAKI S. Domestic Heating

YUTAKI S. Domestic Heating YUTAKI S ECOLOGY & COMFORT OUTDOOR UNIT RAS 3HVRNME-AF YUTAKI-S MODULE RWM 2~10.0HFSN3E The Yutaki S heat pump is the ideal solution both in new installations and refurbishments. Its exceptional performance

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient

More information

NEW 3-PIPE ECOi MF2 SERIES

NEW 3-PIPE ECOi MF2 SERIES NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR

More information

2015 / 16. price list. Airconditioning systems

2015 / 16. price list. Airconditioning systems 2015 / 16 price list Airconditioning systems TERMS OF BUSINESS General As far as nothing else has been declared, the general terms of business and the agreed purchase conditions including the sales discounts

More information

Air Conditioning for Small and Medium-size Buildings

Air Conditioning for Small and Medium-size Buildings Air Conditioning for Small and Medium-size Buildings Defining a HIGHER standard The all-new MiNi-SMMS air conditioner lineup lets you cool or warm as many as 12 *1 rooms with a single system. Outdoor units

More information

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS POER, FLEXIBILITY, RESIDENTIAL Carrier presents the new line of multi-split systems A complete and flexible range designed to meet every residential and light

More information

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units SALES BULLETIN Key Features 1. Chassis completely re designed 2. Increased product range, now includes 6HP model 3. New features to enable easy installation a. Easy access hanger b. Easier wiring connections

More information

-~ available. Power consumption during operation is substantially less than that of lower rated

-~ available. Power consumption during operation is substantially less than that of lower rated Introduction Specifically designed for small to medium sized areas the SANYO SAP range is the ideal solution when you need quiet, efficient room air conditioning to create a comfortable environment within

More information

The natural ombination

The natural ombination The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,

More information

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE AquaFREE system Technical Catalogue Outdoor units: RAS(3~5)HVRNE RAS(4/5)HRNE Indoor units: RWM(3~5)FSN1E RWM(3~5)FSN1E(4.5/6)H(1/3) RWM(3~5)FSN1ES1 RWM(3~5)FSN1E(4.5/6)SH(1/3) Specifications in this

More information

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT UP TO 15 SEER Performance MINI-SPLIT SYSTEM UNITS AIR CONDITIONING AND HEAT PUMPS COMPLETE ROOM COMFORT WITH EASY-TO-USE REMOTE CONTROL HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT The Goodman brand offers

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008 Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: Test Report issued under the responsibility of: TEST REPORT EHPA-DACH Testing Regulation Supplemental requirements for granting the international quality label for heat pumps Testing of Air/Water Heat

More information

How To Design A Building In New Delhi

How To Design A Building In New Delhi ENERGY EFFICIENT HVAC DESIGN FOR COMPOSITE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce energy consumption

More information

FCQ. Roundflow Cassette Heat Pump or Cooling Only

FCQ. Roundflow Cassette Heat Pump or Cooling Only FCQ Roundflow Cassette Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FCQ roundflow cassette SkyAir systems are ideal for open plan applications where variances in temperature and airflow

More information

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce

More information

FBQ. DC Duct Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

FHQ. Ceiling Suspended Heat Pump or Cooling Only

FHQ. Ceiling Suspended Heat Pump or Cooling Only FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this

More information

GREE, MAKING BETTER AIR CONDITIONERS

GREE, MAKING BETTER AIR CONDITIONERS GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI Add:Jinji RD.Qianshan Zhuhai 519070,Guangdong,China Tel: (+86-756)8614883 Fax: (+86-756)8627140 Email: gree@gree.com.cn http://www.gree.com.cn Heat Pump Water Heater

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

Daikin Altherma. hybrid heat pump. The natural combination

Daikin Altherma. hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Why choose Daikin? As an industry leader, Daikin combines broad experience, technical innovation and responsive customer service to help you meet

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

2010 Duct-Free Splits Line Card

2010 Duct-Free Splits Line Card 2010 Duct-Free Splits Line Card Right Product for the Right Application 2010 Duct-Free Splits Right Product for the Right Application 1:1 2:1 to 4:1 9-24K High Walls 18-24/36/42/60K High Wall, Cassette,

More information

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

LOCAL AIR-CONDITIONERS

LOCAL AIR-CONDITIONERS LOCAL AIR-CONDITIONERS Local air-conditioners Compact Design Split Design Compact Air-Conditioner Quality with systems REMKO THE CUSTOMER-ORIENTED SYSTEM SUPPLIER FOR THE WHOLE YEAR THROUGH From the development

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

Inverter Air Conditioning for Light Commercial Use

Inverter Air Conditioning for Light Commercial Use Inverter Air Conditioning for Light Commercial Use Index Introducing Light Commercial 4 SDI-Super Digital Inverter 6 DI-Digital Inverter 7 DI Big 8 SDI-Super Digital Inverter & DI-Digital Inverter Lineup

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

PLA. Advancements in PLA series improve style and performance for ensured indoor comfort. 4-way Ceiling Cassette. Wide Airflow.

PLA. Advancements in PLA series improve style and performance for ensured indoor comfort. 4-way Ceiling Cassette. Wide Airflow. 13 4-way Ceiling Cassette PLA SERIES Advancements in PLA series improve style and performance for ensured indoor comfort Wide Air Wide-angle outlets distribute air to all corners of the room, ensuring

More information

FTXS. Wall Mount Heat Pump or Cooling Only

FTXS. Wall Mount Heat Pump or Cooling Only FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both

More information

LG Air Conditioning & Energy Solutions Price List

LG Air Conditioning & Energy Solutions Price List LG Air Conditioning & Energy Solutions Price List Valid from March 2015 Splits VRF Heat Pumps Ventilation Controls Introduction About LG Electronics Air Conditioning and Energy Solutions LG manufactured

More information

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move Air conditioning unit 2. Product information for the new Truma air conditioning unit October 2006 Edition Comfort on the move Air conditioning systems Manoeuvring systems Energy systems Heating systems

More information

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73 MCAC-VTSM-2013-03 R410a Full DC Inverter Mini VRF Contents Part 1 General Information... 1 Part 2 Outdoor Units... 9 Part 3 Installation... 50 Part 4 Troubleshooting 73 Part 5 Control System... 100 Manufacture

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit Ref.-No. SMMS02-AE-10-05 Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H 2-way ceiling cassette MMU-AP0071WH,

More information

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant

More information

Air Conditioning For Large Buildings

Air Conditioning For Large Buildings Air Conditioning For Large Buildings Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

technology innovation, comfort for your home. The perfect blend of

technology innovation, comfort for your home. The perfect blend of The perfect blend of innovation, & technology comfort for your home. Air conditioning for your home is all about comfort. No matter what Australia s harsh climate can dish out. From summer scorchers to

More information

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #31 System Drop-in Test of Refrigerant R-32 in Split Air-conditioning

More information

PRODUCT CATALOG. Indoor Units

PRODUCT CATALOG. Indoor Units PRODUCT CATALOG Indoor Units Life s Good! From installation to maintenance, LG runs more than 60 global air conditioning academies, each provides training for air conditioning professionals. What is LG?

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

Pioneer in sustainability

Pioneer in sustainability Pioneer in sustainability Over 100 years ago Carrier helped pioneer a new industry, and in the last two decades we have pioneered environmentally sensitive products with a reduced impact on the environment.

More information

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and 1 Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and cost-effective, Toshiba aims at the heart of growing

More information

AIR-CONDITIONER SPLIT TYPE

AIR-CONDITIONER SPLIT TYPE FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Residential. Commercial 7-22 23-38. Controls 69-75. Multi XRV Plus System 39-68. Technical courses Key to icons 76-79

Residential. Commercial 7-22 23-38. Controls 69-75. Multi XRV Plus System 39-68. Technical courses Key to icons 76-79 General Catalogue 2014 Air Systems is exclusieve distributor of Hokaido, based in Dubai and present in the Middle East market, Air Systems maintains its competitive edge with a simultaneous focus on our

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hot Water. Heat pump water heaters. Residential and Commercial R410a Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER IN-CEILING CASSETTE Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER TECHNOLOGY PFC Control in Power Input DC Inverter

More information

UTOPIA DC-INVERTER ES SERIES HVRN1/H(V)RNS(E)

UTOPIA DC-INVERTER ES SERIES HVRN1/H(V)RNS(E) UTOPIA DC-INVERTER ES SERIES HVRN1/H(V)RNS(E) Technical Catalogue Outdoor Units: 2~10 HP Indoor Units Type: 4-Way Cassette 2-Way Cassette Wall Ceiling In-the-Ceiling Floor Floor Concealed Specifications

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

AIR CONDITIONING and HEAT PUMP PRODUCTS

AIR CONDITIONING and HEAT PUMP PRODUCTS AIR CONDITIONING and HEAT PUMP PRODUCTS February 2015 The History of Panasonic Air Conditioning The Panasonic Air Conditioning Group has grown into a global company through its continuous quest for product

More information

We have been working in an ideal climate for thirty years.

We have been working in an ideal climate for thirty years. Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the

More information

IR410AI. The flexible solution. Simple, one touch control

IR410AI. The flexible solution. Simple, one touch control The flexible solution The new SANYO Flexi Multi range of heat pump multi split systems are the ideal, flexible solution for providing quiet and efficient air conditioning to 2, 3 or 4 areas from a single

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV

Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV TABLE OF CONTENTS RX-JV/GV 1 Features.............................................................

More information

ECO-AIR AIR CONDITIONING www.northamericanhvac.com

ECO-AIR AIR CONDITIONING www.northamericanhvac.com INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...

More information