Inverter Air Conditioning for Light Commercial Use

Size: px
Start display at page:

Download "Inverter Air Conditioning for Light Commercial Use"

Transcription

1 Inverter Air Conditioning for Light Commercial Use

2 Index Introducing Light Commercial 4 SDI-Super Digital Inverter 6 DI-Digital Inverter 7 DI Big 8 SDI-Super Digital Inverter & DI-Digital Inverter Lineup 10 Indoor units Compact 4-Way Cassette ( ) type 14 4-Way Cassette type 17 Slim Duct type 21 Standard Duct type 24 Concealed Duct High Static Pressure type 28 Ceiling type 30 High-Wall type 34 Twin, Triple & Double twin system 37 SDI-Super Digital Inverter & DI-Digital Inverter Controllers & Accessories 42 SPI 44 SPI Indoor units Appendix Outdoor unit drawings 50

3 3 SDI Super Digital Inverter DI Digital Inverter SPI Toshiba solutions Toshiba offers a solution for all applications: residential, light commercial and larger commercial buildings. For small commercial premises, products are designed to deliver top performance combined with energy efficiency. Superior comfort Toshiba s commitment to society drives a company-wide focus on attention to the details through every stage of the development process, from design to user field tests. Installations using our products and systems therefore feature a higher standard of indoor air quality, sound levels, energy savings, and environmental awareness. Toshiba can help you create a comfortable space while also caring for the environment.

4 4 Light Commercial The Toshiba Super Digital Inverter and Digital Inverter series air conditioners combine economy and ecology in a compact body. They feature state-of-the-art technology, flexible control, and easy installation to bring natural comfort and convenience to any business environment. A complete range of indoor units: Cassette, Ducted, Ceiling and High-Wall units Superior EER Very efficient energy consumption, Keeps down operating costs. EER of 4.52* achieved by Toshiba s unrivalled Super Digital Inverter technologies and newly developed components. *4HP outdoor unit, Heating ECO-driving DC twin rotary Super Digital Inverter / New 4-Way Cassette (EER) HP 3 HP 4 HP 5 HP Digital Inverter / New 4-Way Cassette (EER) HP 3 HP 4 HP 5 HP Vector-controlled inverter Vector IPDU control changes the motor current wave to a smooth sine pattern so that noise emitted from the drive units is greatly reduced. High efficiency heat-transfer (flat fin) Heat-transfer tube with improved heat-transfer coefficient. A low minimum speed of 10 rps has been achieved. This has further improved the operating efficiency when the load is low (the minimum in Series 2 was 15 rps). High power motor DC fan motor Highly Efficient DC Motor. Bat wing fan New development for high-pressure low-volume fan. Wide-flow grille Optimizing ventilation performance, Bringing out the full effect of fan and motor. DC twin rotary A low minimum speed of 10 rps has been achieved. Operation in Power Save Mode enables power peaks to be cut. Newly designed compression path More precise components Rotor with slit The structure and shape of each compressor component has been optimised. The area of the rotor magnet has been increased and a slit introduced to the design. These improvements have further Large-area magnet enhanced efficiency and reduced noise. Note: Actual component may vary considerably from specifications depending on product model.

5 5 R410A refrigerant An ozone layer depletion coefficient of zero has become absolutely essential for an advanced air conditioning system. Twin split System Fits with various size room and form - Combination : Same type and capacity of indoor units - Twin kit Line up Super Digital Inverter -15 C to 43 C Outdoor temp. range when cooling* Outdoor temp. range when heating* * Digital Inverter -20 C to 15 C -15 C to 15 C *Cooling : CDB, Heating: CWB Heating operation range Quiet operation Super Digital Inverter Low-noise design. If the outdoor temperature is 30 C or less, operates at under 45 db. It s possible to automatically operate the quiet operation mode below 35 C air temperature. Digital Inverter -20 C -15 C 0 C 15 C Operating temperature range Heater operation is possible starting from an outdoor temperature of -20 C creates a comfortable space even during cold winters, while cooling operation is possible at -15 C outdoor temperature. This enables wider applications and use of the system in colder regions. Pipes can be reused Super Digital Inverter & Digital Inverter series 4 systems eqipped with R410A refrigerant can use old piping designed for old R22 or R407c refrigerant in case of replacment. Self-Clean operation-continuing high performance for energy saving This enables the 4-Way Cassette type and Ceiling type to maintain energy efficiency at the time of purchase for a long time. Self-Clean Operation - The mechanism of the wash-off Water 1. The aqua resin coating prevents dirt from sticking to the fins. Oil/ Dirt Aqua resin coating 2. The condensation water flows and washes away dirt. 3. After washing, a drying operation suppresses the propagation of mold.

6 6 SDI Super Digital Inverter Latest technology: Newly developed DC twin-rotary compressor, Vector-controlled inverter, Larger propeller fan, High efficiency DC fan motor, High efficiency heat-transfer and New grille design has excellent efficiency, not only under rated EER conditions, but also during partial load which is the larger part of actual operating conditions. Low-noise design: If the outdoor temperature is 30 C or less, operates at under 45 db The industry s first magnetic-action control The new structure allows a huge reduction in energy loss. The balanced magnetic-action force to rise and the rotor s weight minimized the friction laid on the axis provides excellent operation efficiency. Current model New model Magnetic action Magnetic center Stator Rotor Rotor s weight Friction loss Reducing friction loss Outdoor temperature operating range in heating (Wider heating operation) Heater operation is possible starting from an outdoor temperature of -20 C, while cooling operation is possible at -15 C outdoor temperature. Creates a comfortable space even during cold winters. Frost protection 8 C operation for frost protection is possible for the combination with Super Digital Inverter. (4-Way and Slim Duct series 4) Sub cool path Improve reliability for smooth drainage. The outdoor unit of New Super Digital Inverter is equipped with Sub cool path Preventing freeze under a heat exchanger. (Only 3HP to 6HP) Compatible with pipes up to 75 meters long Enable the outdoor unit to be installed out of sight increases installation flexibility.

7 7 DI Digital Inverter Extremely lightweight and compact outdoor unit Lighter than the current model by 8 kg (11%) 4 HP 5 HP 1104ATP-E 1404ATP-E 68kg previous model:76kg -8kg Remarkable energy efficiency Industry s top-class energy-saving (Max.10%UP) Small compact size chassis Reduces installation spaces and enables a more efficient use of the site. Easy to install the outdoor units on a double-decked and easy to install on a wall. Current model New model Wide-Utility function Heater operation is possible starting from an outdoor temperature of -20 C, while cooling operation is possible at -15 C and up to 46 outdoor temperature. This enables wider applications and use of the system in colder regions. Outstandingly quiet operation & save operation setting Night operation make it possible to suppress the operation sound of the outdoor unit within the time which you desire. (12dB(A) reduction)* *5HP Outdoor unit, Heating. Save operation setting is available from 50% to 100% by 1% Quiet operation & save operation setting available for 2HP, 3HP, 4HP and 5HP Note: Night operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E) Save operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E), RBC-AMT32E Easy and safty operation for maintenance of the outdoor unit. Inspection window makes it easy to find switch that requires operation and reduces the risk of electrical shock. 2,3 HP 4,5 HP Inspection window Cover Maintenance Switch (2 tact switches) Maintenance light (6LED)

8 8 DIBIG DI Big proposes competitive cost systems solution for medium size applications like Shops and Small Office buildings. Simultaneous operation of 2, 3 or up to 4 indoor unit can be installed as twin, triple and double twin systems with single outdoor unit. Compact outdoor unit Small footprint in only 0.29 m2, Compact design in size (W 900mmx D 320mm) allows opportunity for more space saving. High efficiency EER/COP* performance DI Big is equipped with a new twin-rotary DC inverter compressor with high efficiency R410A refrigerant. A new technology twin-rotary DC compressor, 100W +100W output Highly-efficient DC fan motor, propeller fan for newly developed 3-row heat exchanger. *EER / COP = 3.21 / 3.85 ( With 4-way cassette twin system of 8HP), EER / COP = 2.81 / 3.61 ( With 4-way cassette twin system of 10HP) Screw connection for larger current Wider discharge port for less pressure loss Decreasing oil discharge for reliability Compact & higher efficiency motor 1.Rare metal magnet 2.Highly concentrated & optimized winding Larger displacement cylinder (55cm3/rev) Expanded operating temperature range Air conditioning system designing is easy with DI-BIG because of its expanded operation range. Heater operation is possible starting from an outdoor temperature of -20 C, while cooling operation is possible at -15 C and up to 46 outdoor temperature. This enables wider applications and use of the system in colder regions. DI BIG Outdoor temp. range when cooling* -15 C to 46 C Outdoor temp. range when heating* -20 C to 15 C Heating operation range *Cooling : CDB, Heating: CWB DI BIG -20 C -15 C 0 C 15 C Compatible with pipes up to 70 meters long with a maximum height difference of 30 meters height

9 9 4-way Cassette Type Duct Type Ceiling Type High-wall Type

10 10 Outdoor units combinations Super Digital Inverter 1-phase model Equivalent HP 1.5HP 1.7HP 2HP 3HP 4HP 5HP Standard model SP404ATP-E SP454ATP-E SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E Light Anti-Corrosion protection model SP1104ATZ-E SP1404ATZ-E Heavy Anti-Corrosion protection model - - SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E Compact 4-Way Cassette type Single SM404MUT-E SM454MUT-E SM564MUT-E N/A N/A N/A Twin N/A N/A N/A SM404MUT-E x 2 SM564MUT-E x 2 N/N 4-Way Cassette type Triple N/A N/A N/A N/A N/A N/A Single N/A N/A SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E Twin N/A N/A N/A N/A SM564UTP-E x 2 SM804UTP-E x 2 Slim Duct type Triple N/A NA N/A N/A NA N/A Single SM404SDT-E SM454SDT-E SM564SDT-E N/A N/A N/A Twin N/A N/A N/A SM404SDT-E x 2 SM564SDT-E x 2 N/A Standard Duct type Triple N/A N/A N/A N/A N/A N/A Single SM406BT-E, SM406BTP-E SM456BT-E, SM456BTP-E SM566BT-E, SM566BTP-E SM806BT-E, SM806BTP-E SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E Twin N/A N/A N/A SM406BT-E x 2, SM406BTP-E x 2 SM566BT-E x 2, SM566BTP-E x 2 SM806BT-E x 2, SM806BTP-E x 2 Triple N/A N/A N/A N/A N/A N/A Ceiling type Single N/A N/A SM567CTP-E SM807CTP-E SM1107CTP-E SM1407CTP-E Twin N/A N/A N/A N/A SM567CTP-E x 2 SM807CTP-E x 2 Triple N/A N/A N/A N/A N/A N/A High-Wall type Single N/A N/A SM566KRT-E SM806KRT-E N/A N/A Twin N/A N/A N/A N/A SM566KRT-E x 2 SM806KRT-E x 2 Triple N/A N/A N/A N/A N/A N/A *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber

11 11 Digital Inverter 1-phase model Equivalent HP 2HP 3HP 4HP 5HP 6HP Standard model SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model SM1603ATZ-E Heavy Anti-Corrosion protection model SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Compact 4-Way Cassette type Single SM564MUT-E N/A N/A N/A N/A Twin N/A N/A SM564MUT-E x 2 N/A N/A 4-Way Cassette type Triple N/A N/A N/A N/A SM564MUT-E x 3 Single SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E SM1604UTP-E Twin N/A N/A SM564UTP-E x 2 SM804UTP-E x 2 SM804UTP-E x 2 Slim Duct type Triple N/A N/A N/A N/A SM564UTP-E x 3 Single SM564SDT-E N/A N/A N/A N/A Twin N/A N/A SM564SDT-E x 2 N/A N/A Standard Duct type Triple N/A N/A N/A N/A SM564SDT-E x 3 Single SM566BT-E, SM566BTP-E SM806BT-E, SM806BTP-E SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E SM1606BT-E, SM1606BTP-E Twin N/A N/A SM566BT-E x 2, SM566BTP-E x 2 SM806BT-E x 2, SM806BTP-E x 2 SM806BT-E x 2, SM806BTP-E x 2 Triple N/A N/A N/A N/A SM566BT-E x 3, SM566BTP-E x 3 Ceiling type Single SM567CTP-E SM807CTP-E SM1107CTP-E SM1407CTP-E SM1607CTP-E Twin N/A N/A SM567CTP-E x 2 SM807CTP-E x 2 SM807CTP-E x 2 Triple N/A N/A N/A N/A SM567CTP-E x 3 High-Wall type Single SM566KRT-E SM806KRT-E N/A N/A N/A Twin N/A N/A SM566KRT-E x 2 SM806KRT-E x 2 SM806KRT-E x 2 Triple N/A N/A N/A N/A SM566KRT-E x 3 *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber

12 12 Outdoor units combinations Super Digital Inverter 3-phase model Equivalent HP 4HP 5HP 6HP Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E 50Hz Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 60Hz Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG Compact 4-Way Cassette type Single N/A N/A N/A Twin SM564MUT-E x 2 N/A N/A 4-Way Cassette type Triple N/A N/A SM564MUT-E x 3 Double twin N/A N/A N/A Single SM1104UTP-E SM1404UTP-E SM1604UTP-E Twin SM564UTP-E x 2 SM804UTP-E x 2 SM804UTP-E x 2 Slim Duct type Triple N/A N/A SM564UTP-E x 3 Double twin N/A N/A N/A Single N/A N/A N/A Twin SM564SDT-E x 2 N/A N/A Standard Duct type Triple N/A N/A SM564SDT-E x 3 Double twin N/A N/A N/A Single SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E SM1606BT-E, SM1606BTP-E Twin SM566BT-E x 2, SM566BTP-E x 2 SM806BT-E x 2, SM806BTP-E x 2 SM806BT-E x 2, SM806BTP-E x 2 Ceiling type Triple N/A N/A SM566BT-E x 3, SM566BTP-E x 3 Double twin N/A N/A N/A Single SM1107CTP-E SM1407CTP-E SM1607CTP-E Twin SM567CTP-E x 2 SM807CTP-E x 2 SM807CTP-E x 2 High-Wall type Triple N/A N/A SM567CTP-E x 3 Double twin N/A N/A N/A Single N/A N/A N/A Twin SM566KRT-E x 2 SM806KRT-E x 2 SM806KRT-E x 2 Triple N/A N/A SM566KRT-E x 3 Double twin *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber N/A N/A N/A

13 13 Digital Inverter Big 3-phase model Equivalent HP 8HP 10HP Standard model SM2244AT8-E SM2804AT8-E 50Hz Light Anti-Corrosion protection model SM2244AT8Z-E SM2804AT8Z-E Heavy Anti-Corrosion protection model SM2244AT8ZG-E SM2804AT8ZG-E Standard model SM2244AT7 SM2804AT7 60Hz Light Anti-Corrosion protection model SM2244AT7Z SM2804AT7Z Heavy Anti-Corrosion protection model SM2244AT7ZG SM2804AT7ZG Compact 4-Way Cassette type Single N/A N/A Twin N/A N/A 4-Way Cassette type Triple N/A N/A Double twin SM564MUT-E x 4 N/A Single N/A N/A Twin SM1104UTP-E x 2 SM1404UTP-E x 2 Slim Duct type Triple SM804UTP-E x 3 SM804UTP-E x 3 Double twin SM564UTP-E x 4 SM804UTP-E x 4 Single N/A N/A Twin N/A N/A Standard Duct type Triple N/A N/A Double twin SM564SDT-E x 4 N/A Single N/A N/A Twin SM1106BT-E x 2, SM1106BTP-E x 2 SM1406BT-E x 2, SM1406BTP-E x 2 Concealed Duct High Static Pressure type Triple SM806BT-E x 3, SM806BTP-E x 3 SM806BT-E x 3, SM806BTP-E x 3 Double twin SM566BT-E x 4, SM566BTP-E x 4 SM806BT-E x 4, SM806BTP-E x 4 Single SM2242DT-E * SM2802DT-E * Twin N/A N/A Ceiling type Triple N/A N/A Double twin N/A N/A Single N/A N/A Twin SM1107CTP-E x 2 SM1407CTP-E x 2 High-Wall type Triple SM807CTP-E x 3 SM807CTP-E x 3 Double twin SM567CTP-E x 4 SM807CTP-E x 4 Single N/A N/A Twin N/A N/A Triple SM806KRT-E x 3 SM806KRT-E x 3 Double twin * : RAV-SM***2DT-E can be connected to RAV-SM***4AT8-E only. *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber SM566KRT-E x 4 SM806KRT-E x 4

14 14 Compact 4-Way Cassette type Perfectly fit for 600 x 600 grid system ceiling Perfect for grid system ceiling This compact unit (575 x 575 mm) fits perfectly into ceilings and matches standard architectural modules, without the need to cut ceiling tiles. RAV-SM 4MUT-E Panel Designed for simple & easy installation and maintenance The slim flat stylish panel design is only 268 mm in height even when an electrical box is located inside the unit. Easy access to electrical box is achieved by simply removing the suction grill. Easy installation is also possible using the panel adjust pocket. Use the adjust pocket function for fine adjustments after installation. The drain up height is 850 mm. Available for ceilings up to 3.5 m in height. RBC-UM11PG(W)-E 3.5m Maximum height Compact 4-Way Cassette type Super Digital Inverter and Digital Inverter Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Long-life Filter Built-in long-life filter makes maintenance easier. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Auto-turn Louvre Air outlet grilles move automatically to fill every corner of the room with warm or cool air.. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Limit Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low. Dry Gradually dehumidifies. the room to create even greater comfort..

15 SDI-Super Digital Inverter Outdoor unit Standard model SP404ATP-E SP454ATP-E SP564ATP-E Light Anti-Corrosion protection model Heavy Anti-Corrosion protection model - - SP564ATJP-E Indoor unit SM404MUT-E SM454MUT-E SM564MUT-E Cooling* 1 Heating* 1 Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Performance data Capacity 100% Capacity 80% Capacity 50% DI-Digital Inverter Outdoor unit Physical data Indoor unit SM404MUT-E SM454MUT-E SM564MUT-E Standard air flow (H/M/L) m 3 /h 660/552/ /552/ /672/546 Sound pressure level (H/M/L) db(a) 40/36/31 40/36/31 43/39/34 Sound power level (H/M/L) db(a) 55/51/46 55/51/46 58/54/49 Main unit dimensions (H/W/D) mm 268/575/ /575/ /575/575 Weight kg Panel dimensions (H/W/D) mm 27/700/700 27/700/700 27/700/700 Panel weightl kg Physical data Equivalent HP 1.5HP 1.7HP 2HP 2HP Outdoor unit Standard model SM564ATP-E Light Anti-Corrosion protection model - Heavy Anti-Corrosion protection model SM564ATJP-E Indoor unit SM564MUT-E Cooling* 1 Heating* 1 Capacity kw 5.0 Range, min-max kw Power consumption kw 1.65 EER (Energy Efficiency Ratio) Capacity 100% 3.03 Capacity 80% 3.81 Capacity 50% 4.90 Capacity kw 5.3 Range, min-max kw Power consumption kw 1.52 COP (Coefficient of Performance) Performance data Capacity 100% 3.49 Capacity 80% 3.93 Capacity 50% 4.91 Power supply 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V Standard model SP404ATP-E SP454ATP-E SP564ATP-E SM564ATP-E Light Anti-Corrosion protection model Heavy Anti-Corrosion protection model RAV-) - - SP564ATJP-E SM564ATJP-E Power supply 1-phase 50Hz 230V ( V) 1-phase 50Hz 230V ( V)/ 1-phase 60Hz 220V Compressor type DC twin rotary DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4 Min. pipe length m Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 550/780/ /780/ /780/ /780/290 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 45/47 45/47 47/48 46/48 Sound power level, Cooling/Heating db(a) 62/64 62/64 63/64 63/65 Operating range, Cooling/Heating C -15~43 / -15~15-15~43 / -20~15-15~46 / -15~15

16 16 RAV-SM***4MUT-E Celling bottom surface Knockout square hole φ150 φ Celling bottom surface Electric parts box Knockout for air intake φ Check port ( 450) Refrigerant pipe connecting port (Gas side) Refrigerant pipe connecting port (Liquid side) Wiring connection port 21 For branch duct knockout square hole φ150 NOTE: As ABS is used for the drain discharge port of the main unit, the vinyl chloride paste cannot be used. Use the flexible hose (Band fix) included in the package. Hanging bolt pitch 525 Ceiling open dimension 595 to 660 Panel external dimension Bottom face of ceiling 177 Hanging bolt pitch Ceiling open dimension 595 to 660 Drain standing-up size Ceiling open dimension 595 to 660 Panel external dimension Hanging bolt M10 or W3/8 procured locally Space required for installation and servicing φ162 Drain pipe connecting port 1000 or more 1000 or more Bottom face of ceiling Ceiling panel(sold separately) 1000 or more 15 or more Obstacle Ceiling open dimension 595 to 660 Indoor unit Model RAV- A B C D SM404MUT-E, SM454MUT-E, SM564MUT-E or more 300 Stand-up or less Stand-up 850 or less (Unit: mm) Options TCB-FF101URE2 Ceiling panel RBC-UM11PG(W)E

17 17 4-Way Cassette type The wide air flow in all direction Multi-louver individual control RAV-SM 4UTP-E Panel Wide flow louver type Individual louver control enables airflow to be chosen according to user preferences. The angles of each louver can be set individually in 3 different choices of swing patterns; Standard swing, Diagonally opposite swing and Turn-around swing (1) Standard swing (2) Diagonally opposite swing (3) Turn-around swing RBC-U31PGP(W)-E New Long-life pre-filter A new long-life pre-filter has a surface 1.5 times of current filters to improve Dust-collection performance. RBC-U31PGP(WS)-E Straight flow louver type Built-in condensate drain pump Easy installation RBC-U31PGS(W)-E* 300mm or less 850mm or less Light weight unit (24kg at 5HP) Easy panel installation, The panel is attached using the bolt that is already installed on the indoor unit. 210mm RBC-U31PGS(WS)-E* *European market only 4-Way Cassette type Super Digital Inverter and Digital Inverter Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Long-life Filter Built-in long-life filter makes maintenance easier. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Individual Louvre control Enables airflows to be chosen according to user preferences.. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Limit Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Auto-turn Louvre Air outlet grilles move automatically to fill every corner of the room with warm or cool air. Dry Gradually dehumidifies the room to create even greater comfort.. Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low..

18 18 SDI-Super Digital Inverter Out door unit Performance data Standard model SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E Light Anti-Corrosion protection model - - SP1104ATZ-E SP1404ATZ-E Heavy Anti-Corrosion protection model SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E Indoor unit SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E Capacity kw Range, min-max kw Cooling* 1 Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Heating* 1 Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% Power supply 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V DI-Digital Inverter Out door unit Performance data Standard model SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model SM1603ATZ-E Heavy Anti-Corrosion protection model SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Indoor unit SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E SM1604UTP-E Capacity kw Range, min-max kw Cooling* 1 Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Heating* 1 Power supply Physical data Indoor unit SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E SM1604UTP-E Standard air flow (H/M/L) m 3 /h 1050/870/ /960/ /1440/ /1440/ /1500/1260 Sound pressure level (H/M/L) db(a) 32/29/28 35/31/28 43/38/33 44/38/34 45/40/36 Sound power level (H/M/L) db(a) 47/44/43 50/46/43 58/53/48 59/53/49 60/55/51 Main unit dimensions (H/W/D) mm 256/840/ /840/ /840/ /840/ /840/840 Weight kg Panel dimensions (H/W/D) mm 30/950/950 30/950/950 30/950/950 30/950/950 30/950/950 Panel weight kg Physical data Equivalent HP 2HP 3HP 4HP 5HP 2HP 3HP 4HP 5HP 6HP Out door unit Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% phase 50Hz 230V ( V) / 1-phase 60Hz 220V 1-phase 50Hz 230V ( V) Standard model SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model - - SP1104ATZ-E SP1404ATZ-E SM1603ATZ-E Heavy Anti-Corrosion protection model SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Power supply 1-phase 50Hz 230V ( V) 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V Compressor type DC twin rotary DC twin rotary 1-phase 50Hz 230V ( V) Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / / / / / / / / 5 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 550/780/ /900/ /900/ /900/ /780/ /780/ /900/ /900/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating * 2 db(a) 47/48 48/49 49/50 51/52 46/48 48/52 53/54 54/55 51/53 Sound power level, Cooling/Heating db(a) 63/64 64/65 66/67 68/69 63/65 65/69 70/71 70/71 68/70 Operating range, Cooling/Heating C -15~43 / -20~15-15~46 / -15~15-15~43 / -15~15

19 19 RAV-SM***4UTP-E Electric parts box Celling Ceiling bottom surface Knockoutfor freshairintake intake φ100 Z Zview Z Hanging bolt pitch Panel external dimension B Hanging bolt pitch Panel external dimension Hanging bolt M10 or (procured by locally) Drain pipe connection port (Material: PP) For branch duct Knockout square hole 860to Ceiling open dimension ension Ceiling open dimension 860 to910 ension Refrigerant pipe connecting port (Liquid side) Refrigerant pipe connecting port (Gas ide) C D 300orless A Bottom faceofceiling Ceiling Stand-up 661orless Stand-up 850orless Bottom face of ceiling Ceiling Ceiling panel (sold separately) Drain Drain standing-up size For branch duct Knockout square hole Spacerequiredforinstallation installation and servicing and servicing 15 or more Bottom face of ceiling 1000 ormore 1000 orm more 15 or more m ore Take-in port of wiring Model RAV- A B SM564UTP-E SM804UTP-E SM1104UTP-E, SM1404UTP-E, SM1604UTP-E C D or or more more (Unit:mm) Options TCB-FF101URE2 TCB-GFC1602UE Fresh air inlet box TCB-GB1602UE Air discharge direction kit TCB-BC1602UE Spacer for height adjustment Spacer for height adjustment TCB-SP1602UE Ceiling panel RBC-U31PGP(W)-E RBC-U31PGP(WS)-E Air discharge parts A Packing A Air discharge parts B Packing B Refrigerant piping side Drain piping side Air discharge parts C Packing B Air inlet grille

20 20 SDI-Super Digital Inverter Out door unit Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E 50Hz Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E 60Hz Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG Indoor unit SM1104UTP-E SM1404UTP-E SM1604UTP-E Cooling* 1 Heating* 1 Power supply Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Performance data Capacity 100% Capacity 80% Capacity 50% phase 50Hz 400V ( V) / 3-phase 60Hz 380V Physical data Indoor unit SM1104UTP-E SM1404UTP-E SM1604UTP-E Standard air flow (H/M/L) m 3 /h 2010/1440/ /1440/ /1500/1260 Sound pressure level (H/M/L) db(a) 43/38/33 44/38/34 45/40/36 Sound power level (H/M/L) db(a) 58/53/48 59/53/49 60/55/51 Main unit dimensions (H/W/D) mm 319/840/ /840/ /840/840 Weight kg Panel dimensions (H/W/D) mm 30/950/950 30/950/950 30/950/950 Panel weightl kg Physical data Equivalent HP 4HP 5HP 6HP Out door unit 50Hz 60Hz Power supply Compressor type Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG 3-phase 50Hz 400V ( V) / 3-phase 60Hz 380V DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / / 3 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 1340/900/ /900/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 49/50 51/52 51/53 Sound power level, Cooling/Heating db(a) 66/67 68/69 68/70 Operating range, Cooling/Heating C -15~46 / -20~15

21 21 Slim Duct type Slim design for greater application flexibility Functional design Only 210 mm in height for greater application flexibility. RAV-SM 4SDT-E 4-step static pressure setup. Concealed installation within a ceiling void. Auxiliary fresh air intake available. 210mm 210mm Slim & quiet Quiet, powerful operation. Perfect comfort throughout the room and can be used with any style of air diffuser. Slim Duct type Super Digital Inverter and Digital Inverter Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between. High, Low and Very Low. Dry Gradually dehumidifies the room to create even greater comfort. Limit Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Long-life Filter Built-in long-life filter makes maintenance easier...

22 22 SDI-Super Digital Inverter Outdoor unit DI-Digital Inverter Outdoor unit Standard model SM564ATP-E Light Anti-Corrosion protection model - Heavy Anti-Corrosion protection model SM564ATJP-E Indoor unit SM564SDT-E Cooling* 1 Heating* 1 Standard model SP404ATP-E SP454ATP-E SP564ATP-E Light Anti-Corrosion protection model Heavy Anti-Corrosion protection model - - SP564ATJP-E Indoor unit SM404SDT-E SM454SDT-E SM564SDT-E Cooling* 1 Heating* 1 Power supply Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity kw 5.0 Range, min-max kw Power consumption kw 1.91 EER (Energy Efficiency Ratio) Capacity 100% 2.62 Capacity 80% 3.28 Capacity 50% 4.24 Capacity kw 5.3 Range, min-max kw Power consumption kw 1.50 COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Performance data Capacity 100% 3.53 Capacity 80% 3.96 Capacity 50% 4.82 Performance data Capacity 100% Capacity 80% Capacity 50% phase 50Hz 230V ( V) Power supply 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V Physical data Indoor unit SM404SDT-E SM454SDT-E SM564SDT-E Standard air flow (H/M/L) m 3 /h 690/600/ /600/ /678/582 External static pressure-standard (Upper-Lower) Pa Sound pressure level-under air inlet db(a) 39/36/33 39/36/33 45/40/36 Sound pressure level-back air inlet db(a) 30/28/26 30/28/26 33/31/28 Sound power level (H/M/L) db(a) 54/51/48 54/51/48 60/55/54 Dimensions (H/W/D) mm 210/845/ /845/ /845/645 Weightl kg Physical data Equivalent HP 1.5HP 1.7HP 2HP 2HP Standard model SP404ATP-E SP454ATP-E SP564ATP-E SM564ATP-E Outdoor unit Light Anti-Corrosion protection model Heavy Anti-Corrosion protection model RAV-) - - SP564ATJP-E SM564ATJP-E Power supply 1-phase 50Hz 230V ( V) 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V Compressor type DC twin rotary DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4 Standard / Min. pipe length m 7.5 / / / / 5 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 550/780/ /780/ /780/ /780/290 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 45/47 45/47 47/48 46/48 Sound power level, Cooling/Heating db(a) 62/64 62/64 63/64 63/65 Operating range, Cooling/Heating C -15~43 / -15~15-15~43 / -20~15-15~46 / -15~15

23 4-Ø4 23 RAV-SM**4SDT-E Ø (inside) (inside) Refrigerant piping Fresh air inlet (knock-out hole) Hung-up plate Drain-up port (Unit:mm) Options TCB-FF101URE2

24 24 Standard Duct type Wide range of application opportunities Compact sizing Compact size especially in height (275 mm), new slimmer chassis offers wide range of installation opportunities to customer. RAV-SM 6BT-E RAV-SM 6BTP-E 275mm 275mm High static pressure Spigot shaped flange External static pressure can be raised as high as 120 Pa, so that all areas of the room can be reached for even temperature distribution, no matter how complex the layout. Built-in High-lift drain pump TCB-SF56C6BEP The flexible piping layout is made possible by an optionally available drain-pump kit that raises the drain piping up to 29 cm from the drain port. Flexible duct is accessible, Allows complete design flexibility TCB-SF80C6BEP TCB-SF160C6BEP Polygonal rooms Narrow rooms Rooms with fixtures and obstacles New spigot shaped flange as new accessories New spigot shaped flange has higher static pressure with optimized design, the static pressure drops only 20Pa from rectangle flange states. Maximum Static pressure will be 100Pa* with all models. (*static pressure with filter which included in, and intake from back ward) Standard Duct type Super Digital Inverter and Digital Inverter Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between. High, Low and Very Low. Dry Gradually dehumidifies the room to create even greater comfort. Limit Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Long-life Filter Built-in long-life filter makes maintenance easier...

25 SDI-Super Digital Inverter Out door unit Indoor unit Standard model SP404ATP-E SP454ATP-E SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E Light Anti-Corrosion protection model SP1104ATZ-E SP1404ATZ-E Heavy Anti-Corrosion protection model - - SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E SM406BT-E, SM406BTP-E SM456BT-E, SM456BTP-E SM566BT-E, SM566BTP-E SM806BT-E, SM806BTP-E SM1106BT-E, SM1106BTP-E Performance data SM1406BT-E, SM1406BTP-E Capacity kw Range, min-max kw Cooling* 1 Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Heating* 1 Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% Power supply DI-Digital Inverter Out door unit Indoor unit Standard model SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model SM1603ATZ-E Heavy Anti-Corrosion protection model SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E SM566BT-E, SM566BTP-E SM806BT-E, SM806BTP-E 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V SM1106BT-E, SM1106BTP-E* SM1406BT-E, SM1406BTP-E Performance data SM1606BT-E, SM1606BTP-E Capacity kw Range, min-max kw Cooling* 1 Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Heating* 1 Power supply Physical data Indoor unit Physical data Equivalent HP 1.5HP 1.7HP 2HP 3HP 4HP 5HP 2HP 3HP 4HP 5HP 6HP Out door unit Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% SM406BT-E, SM406BTP-E 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V SM456BT-E, SM456BTP-E SM566BT-E, SM566BTP-E SM806BT-E, SM806BTP-E 1-phase 50Hz 230V ( V) SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E SM1606BT-E, SM1606BTP-E Standard air flow (H/M/L) m 3 /h 798/630/ /630/ /630/ /930/ /1650/ /1650/ /1650/1260 External static pressure (factory setting) Pa External static pressure-standard (Upper-Lower) Pa 30(120-30) 30(120-30) 50(120-30) Sound pressure level (H/M/L) db(a) 33/29/25 33/29/25 33/29/25 34/30/26 40/36/33 40/36/33 40/36/33 Sound power level (H/M/L) db(a) 48/44/40 48/44/40 48/44/40 49/45/41 55/51/48 55/51/48 55/51/48 Dimensions (H/W/D) mm 275/700/ /700/ /700/ /1000/ /1400/ /1400/ /1400/750 Weight kg Standard model SP404ATP-E SP454ATP-E SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model SP1104ATZ-E SP1404ATZ-E SM1603ATZ-E Heavy Anti-Corrosion protection model - - SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Power supply 1-phase 50Hz 230V ( V) 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V Compressor type DC twin rotary DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø12.7 / ø6.4 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / / / 5 Max. pipe total length m Maximum height difference m phase 50Hz 230V ( V) Outer dimensions (H/W/D) mm 550/780/ /900/ /900/ /780/ /900/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 45/47 45/47 47/48 48/49 49/50 51/52 46/48 48/52 53/54 54/55 51/53 Sound power level, Cooling/Heating db(a) 62/64 62/64 63/64 64/65 66/67 68/69 63/65 65/69 70/71 70/71 68/70 Operating range, Cooling/Heating C -15~43 / -15~15-15~43 / -20~15-15~46 / -15~15-15~43 / -15~15

26 26 RAV-SM***6BT(P)-E Space required for installation and servicing Ceiling 100 or more Air outlet D 700 or more Service door (Ceiling opening) Floor surface Refrigerant pipe connecting port (Liquid side) G 108 Refrigerant pipe connecting port (Gas side) F or more anging Hanging olt bolt pitc pitcha A Unit Unit e ternal external dimensionb B ternal External dimensions of flangec C 2500 or more or more E ( E for maintenance of air filter ) Flexible Fle i le drain hose ose (Accessory) (Accessor ) Drain pipe connecting port /100 or or more downward do n ard At the t e time of natural drainage Wires ire s dra ing out drawing-out port 18 Under Under air air intake inta e typet pe Model RAV- SM406BT(P)*-E, SM406BT(P)-E, SM456BT(P)-E, SM456BT(P)*-E, SM566BT(P)-E SM566BT(P)*-E SM806BT(P)*-E SM806BT(P)-E SM1106BT(P)*-E, SM1106BT(P)-E, SM1406BT(P)-E, SM1406BT(P)*-E, SM1606BT(P)-E SM1606BT(P)*-E A B C D E F G D (Unit:mm) Options TCB-SF56C6BE TCB-SF80C6BE TCB-SF160C6BE TCB-SF56C6BE TCB-SF80C6BE Model TCB-SF56C6BE TCB-SF80C6BE TCB-SF160C6BE Compatible SM406BT(P)-E, SM406BT(P)*-E, SM456BT(P)-E, SM456BT(P)*-E, SM566BT(P)-E SM566BT(P)*-E SM806BT(P)-E SM806BT(P)*-E SM1106BT(P)-E, SM1106BT(P)*-E, SM1406BT(P)-E, SM1406BT(P)*-E SM1606BT(P)-E TCB-SF160C6BE (Unit:mm)

27 27 SDI-Super Digital Inverter Out door unit Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E 50Hz Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E 60Hz Indoor unit Cooling* 1 Heating* 1 Power supply Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E SM1606BT-E, SM1606BTP-E Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Performance data Capacity 100% Capacity 80% Capacity 50% phase 50Hz 400V ( V) / 3-phase 60Hz 380V Physical data Indoor unit SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E SM1606BT-E, SM1606BTP-E Standard air flow (H/M/L) m 3 /h 2100/1650/ /1650/ /1650/1260 External static pressure (factory setting) Pa External static pressure Pa (7 steps) Sound pressure level (H/M/L) db(a) 40/36/33 40/36/33 40/36/33 Sound power level (H/M/L) db(a) 55/51/48 55/51/48 55/51/48 Dimensions (H/W/D) mm 275/1400/ /1400/ /1400/750 Weight kg Physical data Equivalent HP 4HP 5HP 6HP Out door unit 50Hz 60Hz Power supply Compressor type Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG 3-phase 50Hz 400V ( V) / 3-phase 60Hz 380V DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / / 3 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 1340/900/ /900/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 49/50 51/52 51/53 Sound power level, Cooling/Heating db(a) 66/67 68/69 68/70 Operating range, Cooling/Heating C -15~46 / -20~15

28 28 Concealed Duct High Static Pressure type Satisfies all your design needs Design flexibility Compatible with external static pressures up to 196 Pa. RAV-SM 2DT-E 3-steps-switchable static pressure Low Middle High External static pressure (Pa) Large air volume, Duct high static pressure type is most suitable for the large rooms. Long-life filters fitted as standard. Can be equipped with the following options: high-efficiency filter (65, 90) drain pump kit. *Factory setting : 137Pa Construction characteristics The flexible duct is accessible. Constant temperature setting is possible in large rooms or factories. Easy service and installation. Enable to maintain the blower section from unit side for maintenance and repair. Drain pump kit is available as optional parts up to 330 mm from unit bottom. Enable to select auto restart operation (set from wired remote controller) Concealed Duct High Static Pressure type DI BIG Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between. High, Low and Very Low. Dry Gradually dehumidifies the room to create even greater comfort. Limit Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Long-life Filter Built-in long-life filter makes maintenance easier...

29 DI BIG Performance data Outdoor MML-AP***4NH-E unit SM2244AT8-E SM2804AT8-E Indoor unit SM2242DT-E SM2802DT-E Cooling* 1 Heating* 1 Power supply Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% phase 50Hz V 29 Physical data Indoor unit SM2242DT-E SM2802DT-E Standard air flow at 137Pa/ (at Mid tap) m 3 /h External static pressure (H/M/L) Pa 196/137/68.6 Sound pressure level (H/M/L) db(a) Sound power level (H/M/L) db(a) Dimensions (H/W/D) mm 470/1380/ /1380/1250 Weight kg Physical data Equivalent HP 8HP 10HP Outdoor unit SM2244AT8-E SM2804AT8-E Power supply 3-phase 50Hz V Compressor type DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø28.6 / ø12.7 ø28.6 / ø12.7 Min. pipe length m Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 1540/900/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 56/57 57/58 Sound power level, Cooling/Heating db(a) 72/74 74/75 Operating range, Cooling/Heating C -15~46 / -20~15 RAV-SM***2DT-E Options (Unit:mm) Air discharge port Screw hole for duct mounting (10-M6) Hole for hanging bolt ( ) 1288 (Hanging bolt mounting pitch) (Hanging bolt mounting pitch) Electric parts box Power supply/communication piping port (Ø26) (Under electric parts box) Filter chamber TCB-FCY100DE TCB-PF3DE Air suction port * Refrigerant pipe connecting port (Gas side Brazed) Refrigerant pipe connecting port * (Liquid side 12.7 Flared) 470 Drain pump kit TCB-DP32DE TCB-UFM3DE TCB-UFH7DE Screw hole for duct mounting (10-M6) Drain pipe connecting port (V25) Taper screw for R1,25.4 pipes Space required for installation and serving Diameter of pipe connecting port Liquid side Gas side Diameter of pipe connecting pipe Liquid side Gas side or more or more Service space Check port Service space (Unit:mm)

30 30 Ceiling type Smooth curve design & Low noise level Smooth Curve for pliant Shape All-new chassis and new rounded design, This new models have been developed in response to customers needs for ceiling units that better match their room interiors. RAV-SM 7CTP-E New Designed Wide Flap The new air oulet has realized both High noise reduction and large air volume. Previous model New model Flap control The airflow angle is automatically set to the most suitable setting according to your cooling or heating needs, and an automatic swing mode enables airflow to reach all areas of the room to create a comfortable ambience. 30% Extension Comfortable ambience New fan has adopted the turbulence prevention rib to optimize the ventilating way. Air volume has increased and noise level also has decreased compared with previous model. Winds of new ceiling type of 4HP to 6HP can be reached up to 4.3 metre. Temperature measuring section Previous model New model 8m 8m Center 3m 8m 8m 0.5m above the floor 3m Temperature (deg.c) (C) New Drain pump kit available as an option The Drain pump kit makes draining easier. Anti-bacterial glass built into Drain Pump Kit helps reduce mould formation. Ceiling type Super Digital Inverter and Digital Inverter Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Long-life Filter Built-in long-life filter makes maintenance easier. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Auto-turn Louvre Air outlet grilles move automatically to fill every corner of the room with warm or cool air.. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Limit Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low. Dry Gradually dehumidifies. the room to create even greater comfort..

31 31 SDI-Super Digital Inverter Out door unit Standard model SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E Light Anti-Corrosion protection model - - SP1104ATZ-E SP1404ATZ-E Heavy Anti-Corrosion protection model SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E Indoor unit SM567CTP-E SM807CTP-E SM1107CTP-E SM1407CTP-E Cooling* 1 Heating* 1 Power supply Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Performance data Capacity 100% Capacity 80% Capacity 50% phase 50Hz 230V ( V) / 1-phase 60Hz 220V DI-Digital Inverter Out door unit Standard model SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model SM1603ATZ-E Heavy Anti-Corrosion protection model SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Indoor unit SM567CTP-E SM807CTP-E SM1107CTP-E SM1407CTP-E SM1607CTP-E Cooling* 1 Heating* 1 Power supply Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Capacity 100% Capacity 80% Capacity 50% phase 50Hz 230V ( V) / 1-phase 60Hz 220V Performance data 1-phase 50Hz 230V ( V) Physical data Indoor unit SM567CTP-E SM807CTP-E SM1107CTP-E SM1407CTP-E SM1607CTP-E Standard air flow (H/M/L) m 3 /h 900/720/ /1002/ /1350/ /1530/ /1650/1260 Sound pressure level (H/M/L) db(a) 37/35/28 41/36/29 44/38/32 46/41/35 46/42/36 Sound power level (H/M/L) db(a) 52/50/43 56/51/44 59/53/47 61/56/50 61/57/51 Dimensions (H/W/D) mm 235/950/ /1270/ /1586/ /1586/ /1586/690 Weight kg Physical data Equivalent HP 2HP 3HP 4HP 5HP 2HP 3HP 4HP 5HP 6HP Out door unit Standard model SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model - - SP1104ATZ-E SP1404ATZ-E SM1603ATZ-E Heavy Anti-Corrosion protection model SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Power supply 1-phase 50Hz 230V ( V) 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V Compressor type DC twin rotary DC twin rotary 1-phase 50Hz 230V ( V) Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / / / / / / / / 5 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 550/780/ /900/ /900/ /900/ /780/ /780/ /900/ /900/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 47/48 48/49 49/50 51/52 46/48 48/52 53/54 54/55 51/53 Sound power level, Cooling/Heating db(a) 63/64 64/65 66/67 68/69 63/65 65/69 70/71 70/71 68/70 Operating range, Cooling/Heating C -15~43 / -20~15-15~46 / -15~15-15~43 / -15~15

32 32 RAV-SM***7CTP-E Z A D C B Z view Model RAV- A B C D SM567CTP-E SM807CTP-E SM1107CTP-E, SM1407CTP-E, SM1607CTP-E Spacerequired forinstallation and servicing Hanging bolt Within 50 Ceiling surface Unit 250 or more 250 or more (Front side to be positioned horizontally) (Unit:mm) Options TCB-KP13CE, TCB-KP23CE Elbow piping RBC-AX33CE Wireless remote controller TCB-DP31CE Drain pump kit TCB-PCUC1E Optional connecting kit

33 33 SDI-Super Digital Inverter Out door unit Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E 50Hz Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E 60Hz Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG Indoor unit SM1107CTP-E SM1407CTP-E SM1607CTP-E Cooling* 1 Heating* 1 Power supply Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity kw Range, min-max kw Power consumption kw COP (Coefficient of Performance) Performance data Capacity 100% Capacity 80% Capacity 50% phase 50Hz 400V ( V) / 3-phase 60Hz 380V Physical data Indoor unit SM1107CTP-E SM1407CTP-E SM1607CTP-E Standard air flow (H/M/L) m 3 /h 1860/1350/ /1530/ /1530/1260 Sound pressure level (H/M/L) db(a) 44/38/32 46/41/35 46/42/36 Sound power level (H/M/L) db(a) 59/53/47 61/56/50 61/57/51 Dimensions (H/W/D) mm 235/1586/ /1586/ /1586/690 Weight kg Physical data Equivalent HP 4HP 5HP 6HP Out door unit 50Hz 60Hz Power supply Compressor type Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG 3-phase 50Hz 400V ( V) / 3-phase 60Hz 380V DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / / 3 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 1340/900/ /900/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 49/50 51/52 51/53 Sound power level, Cooling/Heating db(a) 66/67 68/69 68/70 Operating range, Cooling/Heating C -15~46 / -20~15

34 34 High-Wall type Elegant and slim Slim-line design With is attractive, slim-line design, the unit can easily blend in with any room interior. The filtration system further the indoor air quality benefits of this high-wall unit. RAV-SM 6KRT-E Optinum air distribution 70 directional Auto-swing louvre mode allows optimum air distribution throughout the room. Total comfort is granted, thanks also to Automatic air volume control and Automatic cooling/heating. Cooling mode Heating mode Cooling SWING Self cleaning function Toshiba s self-cleaning function is designed to reduce the humidity that causes mold to form inside an air-conditioning unit 20 minutes of fan operation after shut down dries the moist air and helps reduce mold formation on heat exchanger coils. Normal Operation Moisture stays trapped inside Self-cleaning Function 20 minutes of fan operation after shut down dries the moist air and helps reduce mold formation on heat exchanger coils. High-Wall type Super Digital Inverter and Digital Inverter Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. On/Off Timer The operation start and stop times can be set with a digital clock. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Auto-turn Louvre Air outlet grilles move automatically to fill every corner of the room with warm or cool air.. Dry Gradually dehumidifies the room to create even greater comfort. 20 minutes of fan operation after shut down 20 minutes of fan operation after shut down dries the moist air and helps reduce mold formation on heat exchanger coils. Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low...

35 35 SDI-Super Digital Inverter Out door unit Standard model SP564ATP-E SP804ATP-E Light Anti-Corrosion protection model - - Heavy Anti-Corrosion protection model SP564ATJP-E SP804ATJP-E Indoor unit (RAV- SM566KRT-E SM806KRT-E Cooling* 1 Heating* 1 Power supply Capacity (kw) Range, min-max (kw) Power consumption (kw) EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity (kw) Range, min-max (kw) Power consumption (kw) COP (Coefficient of Performance) Performance data Capacity 100% Capacity 80% Capacity 50% phase 50Hz 230V ( V) / 1-phase 60Hz 220V DI-Digital Inverter MML-AP***4NH-E Out door unit Standard model SM564ATP-E SM804ATP-E Light Anti-Corrosion protection model - - Heavy Anti-Corrosion protection model SM564ATJP-E SM804ATJP-E Indoor unit RAV- SM566KRT-E SM806KRT-E Cooling* 1 Heating* 1 Power supply Capacity (kw) Range, min-max (kw) Power consumption (kw) EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% Capacity (kw) Range, min-max (kw) Power consumption (kw) COP (Coefficient of Performance) Performance data Capacity 100% Capacity 80% Capacity 50% phase 50Hz 230V ( V) / 1-phase 60Hz 220V Physical data Indoor unit SM566KRT-E SM806KRT-E Standard air flow (H/M/L) m 3 /h 840/750/ /750/660 Sound pressure level (H/M/L) db(a) 42/39/36 47/41/36 Sound power level (H/M/L) db(a) 57/54/51 62/56/51 Dimensions (H/W/D) mm 320/1050/ /1050/228 Weight kg Physical data Equivalent HP 2HP 3HP 2HP 3HP Out door unit Standard model SP564ATP-E SP804ATP-E SM564ATP-E SM804ATP-E Light Anti-Corrosion protection model Heavy Anti-Corrosion protection model SP564ATJP-E SP804ATJP-E SM564ATJP-E SM804ATJP-E Power supply 1-phase 50Hz 230V ( V) 1-phase 50Hz 230V ( V) / 1-phase 60Hz 220V Compressor type DC twin rotary DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø12.7 / ø6.4 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / / / 5 Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 550/780/ /900/ /780/ /780/290 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level, Cooling/Heating* 2 db(a) 47/48 48/49 46/48 48/52 Sound power level, Cooling/Heating db(a) 63/64 64/65 63/65 65/69 Operating range, Cooling/Heating C -15~43 / -20~15-15~46 / -15~15

36 36 RAV-SM**6KRT-E 1050 Air filter 228 Heat exchanger 50 Knock out 50 Air outlet Air inlet Space required for installation and servicing Space required for installation and servicing 50 Knock out 132 Tab for installation plate Refrigerant connecting pipe (Gas side) A Drain connecting pipe or more Tab for installation plate or more Refrigerant connecting pipe (Liquid side) B 170 or more A B SM566KRT-E SM806KRT-E Model RAV- (Unit:mm)

37 37 Twin, Triple and Double twin system Super Digital Inverter Digital Inverter DI Big Twin OK OK OK Triple OK OK OK Double twin - - OK Twin system : SDI-Super Digital Inverter 1-phase Cooling Indoor unit type Compact 4-Way Cassette 4-Way Cassette Slim Duct Standard Duct Ceiling High-Wall Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SP804AT(J)P-E SM404MUT-E SP1104AT(Z)(ZG)-E SM564MUT-E SP1104AT(Z)(ZG)-E SM564UTP-E SP1404AT(Z)(ZG)-E SM804UTP-E SP804AT(J)P-E SM404SDT-E SP1104AT(Z)(ZG)-E SM564SDT-E SP804AT(J)P-E SM406BT-E, SM406BTP-E SP1104AT(Z)(ZG)-E SM566BT-E, SM566BTP-E SP1404AT(Z)(ZG)-E SM806BT-E, SM806BTP-E SP1104AT(Z)(ZG)-E SM567CTP-E SP1404AT(Z)(ZG)-E SM807CTP-E SP1104AT(Z)(ZG)-E SM566KRT-E SP1404AT(Z)(ZG)-E SM806KRT-E EER Twin system : SDI-Super Digital Inverter 1-phase Heating Indoor unit type Compact 4-Way Cassette 4-Way Cassette Slim Duct Standard Duct Ceiling High-Wall Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SP804AT(J)P-E SM404MUT-E SP1104AT(Z)(ZG)-E SM564MUT-E SP1104AT(Z)(ZG)-E SM564UTP-E SP1404AT(Z)(ZG)-E SM804UTP-E SP804AT(J)P-E SM404SDT-E SP1104AT(Z)(ZG)-E SM564SDT-E SP804AT(J)P-E SM406BT-E, SM406BTP-E SP1104AT(Z)(ZG)-E SM566BT-E, SM566BTP-E SP1404AT(Z)(ZG)-E SM806BT-E, SM806BTP-E SP1104AT(Z)(ZG)-E SM567CTP-E SP1404AT(Z)(ZG)-E SM807CTP-E SP1104AT(Z)(ZG)-E SM566KRT-E SP1404AT(Z)(ZG)-E SM806KRT-E COP Twin system : SDI-Super Digital Inverter 3-phase Cooling Indoor unit type Compact 4-Way Cassette 4-Way Cassette Slim Duct Standard Duct Ceiling High-Wall Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SP1104AT8(Z)(ZG)-E SM564MUT-E SP1104AT7(Z)(ZG) SM564MUT-E SP1104AT8(Z)(ZG)-E SM564UTP-E SP1104AT7(Z)(ZG) SM564UTP-E SP1404AT8(Z)(ZG)-E SM804UTP-E SP1404AT7(Z)(ZG) SM804UTP-E SP1604AT8(Z)(ZG)-E SM804UTP-E SP1604AT7(Z)(ZG) SM804UTP-E SP1104AT8(Z)(ZG)-E SM564SDT-E SP1104AT7(Z)(ZG) SM564SDT-E SP1104AT8(Z)(ZG)-E SM566BT-E, SM566BTP-E SP1104AT7(Z)(ZG) SM566BT-E, SM566BTP-E SP1404AT8(Z)(ZG)-E SM806BT-E, SM806BTP-E SP1404AT7(Z)(ZG) SM806BT-E, SM806BTP-E SP1604AT8(Z)(ZG)-E SM806BT-E, SM806BTP-E SP1604AT7(Z)(ZG) SM806BT-E, SM806BTP-E SP1104AT8(Z)(ZG)-E SM567CTP-E SP1104AT7(Z)(ZG) SM567CTP-E SP1404AT8(Z)(ZG)-E SM807CTP-E SP1404AT7(Z)(ZG) SM807CTP-E SP1604AT8(Z)(ZG)-E SM807CTP-E SP1604AT7(Z)(ZG) SM807CTP-E SP1104AT8(Z)(ZG)-E SM566KRT-E SP1104AT7(Z)(ZG) SM566KRT-E SP1404AT8(Z)(ZG)-E SM806KRT-E SP1404AT7(Z)(ZG) SM806KRT-E SP1604AT8(Z)(ZG)-E SM806KRT-E SP1604AT7(Z)(ZG) SM806KRT-E EER

38 38 Twin, Triple and Double twin system Twin system : SDI-Super Digital Inverter 3-phase Heating Indoor unit type Compact 4-Way Cassette 4-Way Cassette Slim Duct Standard Duct Ceiling High-Wall Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SP1104AT8(Z)(ZG)-E SM564MUT-E SP1104AT7(Z)(ZG) SM564MUT-E SP1104AT8(Z)(ZG)-E SM564UTP-E SP1104AT7(Z)(ZG) SM564UTP-E SP1404AT8(Z)(ZG)-E SM804UTP-E SP1404AT7(Z)(ZG) SM804UTP-E SP1604AT8(Z)(ZG)-E SM804UTP-E SP1604AT7(Z)(ZG) SM804UTP-E SP1104AT8(Z)(ZG)-E SM564SDT-E SP1104AT7(Z)(ZG) SM564SDT-E SP1104AT8(Z)(ZG)-E SM566BT-E, SM566BTP-E SP1104AT7(Z)(ZG) SM566BT-E, SM566BTP-E SP1404AT8(Z)(ZG)-E SM806BT-E, SM806BTP-E SP1404AT7(Z)(ZG) SM806BT-E, SM806BTP-E SP1604AT8(Z)(ZG)-E SM806BT-E, SM806BTP-E SP1604AT7(Z)(ZG) SM806BT-E, SM806BTP-E SP1104AT8(Z)(ZG)-E SM567CTP-E SP1104AT7(Z)(ZG) SM567CTP-E SP1404AT8(Z)(ZG)-E SM807CTP-E SP1404AT7(Z)(ZG) SM807CTP-E SP1604AT8(Z)(ZG)-E SM807CTP-E SP1604AT7(Z)(ZG) SM807CTP-E SP1104AT8(Z)(ZG)-E SM566KRT-E SP1104AT7(Z)(ZG) SM566KRT-E SP1404AT8(Z)(ZG)-E SM806KRT-E SP1404AT7(Z)(ZG) SM806KRT-E SP1604AT8(Z)(ZG)-E SM806KRT-E SP1604AT7(Z)(ZG) SM806KRT-E COP Twin system : DI-Digital Inverter 1-phase Cooling Indoor unit type Capacity EER Outdoor unit name Indoor unit name HP Rated min-max Power consumption 100% 80% 50% (kw) (kw) (kw) Compact 4-Way Cassette SM1104AT(J)P-E SM564MUT-E SM1104AT(J)P-E SM564UTP-E Way Cassette SM1404AT(J)P-E SM804UTP-E SM1603AT(Z)(ZG)-E SM804UTP-E Slim Duct SM1104AT(J)P-E SM564SDT-E SM1104AT(J)P-E SM566BT-E, SM566BTP-E Standard Duct SM1404AT(J)P-E SM806BT-E, SM806BTP-E SM1603AT(Z)(ZG)-E SM806BT-E, SM806BTP-E SM1104AT(J)P-E SM567CTP-E Ceiling SM1404AT(J)P-E SM807CTP-E SM1603AT(Z)(ZG)-E SM807CTP-E SM1104AT(J)P-E SM566KRT-E High-Wall SM1404AT(J)P-E SM806KRT-E SM1603AT(Z)(ZG)-E SM806KRT-E Twin system : DI-Digital Inverter 1-phase Heating Indoor unit type Capacity COP Outdoor unit name Indoor unit name HP Rated min-max Power consumption 100% 80% 50% (kw) (kw) (kw) Compact 4-Way Cassette SM1104AT(J)P-E SM564MUT-E SM1104AT(J)P-E SM564UTP-E Way Cassette SM1404AT(J)P-E SM804UTP-E SM1603AT(Z)(ZG)-E SM804UTP-E Slim Duct SM1104AT(J)P-E SM564SDT-E SM1104AT(J)P-E SM566BT-E, SM566BTP-E Standard Duct SM1404AT(J)P-E SM806BT-E, SM806BTP-E SM1603AT(Z)(ZG)-E SM806BT-E, SM806BTP-E SM1104AT(J)P-E SM567CTP-E Ceiling SM1404AT(J)P-E SM807CTP-E SM1603AT(Z)(ZG)-E SM807CTP-E SM1104AT(J)P-E SM566KRT-E High-Wall SM1404AT(J)P-E SM806KRT-E SM1603AT(Z)(ZG)-E SM806KRT-E

39 39 Twin system : DI Big 3-phase Cooling Indoor unit type 4-Way Cassette Standard Duct Ceiling Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SM2244AT8(Z)(ZG)-E SM1104UTP-E SM2244AT7(Z)(ZG) SM1104UTP-E SM2804AT8(Z)(ZG)-E SM1404UTP-E SM2804AT7(Z)(ZG) SM1404UTP-E SM2244AT8(Z)(ZG)-E SM1106BT-E, SM1106BTP-E SM2244AT7(Z)(ZG) SM1106BT-E, SM1106BTP-E SM2804AT8(Z)(ZG)-E SM1406BT-E, SM1406BTP-E SM2804AT7(Z)(ZG) SM1406BT-E, SM1406BTP-E SM2244AT8(Z)(ZG)-E SM1107CTP-E SM2244AT7(Z)(ZG) SM1107CTP-E SM2804AT8(Z)(ZG)-E SM1407CTP-E SM2804AT7(Z)(ZG) SM1407CTP-E EER Twin system : DI Big 3-phase Heating Indoor unit type 4-Way Cassette Standard Duct Ceiling Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SM2244AT8(Z)(ZG)-E SM1104UTP-E SM2244AT7(Z)(ZG) SM1104UTP-E SM2804AT8(Z)(ZG)-E SM1404UTP-E SM2804AT7(Z)(ZG) SM1404UTP-E SM2244AT8(Z)(ZG)-E SM1106BT-E, SM1106BTP-E SM2244AT7(Z)(ZG) SM1106BT-E, SM1106BTP-E SM2804AT8(Z)(ZG)-E SM1406BT-E, SM1406BTP-E SM2804AT7(Z)(ZG) SM1406BT-E, SM1406BTP-E SM2244AT8(Z)(ZG)-E SM1107CTP-E SM2244AT7(Z)(ZG) SM1107CTP-E SM2804AT8(Z)(ZG)-E SM1407CTP-E SM2804AT7(Z)(ZG) SM1407CTP-E COP Triple system : SDI-Super Digital Inverter 3-phase Cooling Indoor unit type Compact 4-Way Cassette 4-Way Cassette Slim Duct Standard Duct Ceiling High-Wall Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SP1604AT8(Z)(ZG)-E SM564MUT-E SP1604AT7(Z)(ZG) SM564MUT-E SP1604AT8(Z)(ZG)-E SM564UTP-E SP1604AT7(Z)(ZG) SM564UTP-E SP1604AT8(Z)(ZG)-E SM564SDT-E SP1604AT7(Z)(ZG) SM564SDT-E SP1604AT8(Z)(ZG)-E SM566BT-E, SM566BTP-E SP1604AT7(Z)(ZG) SM566BT-E, SM566BTP-E SP1604AT8(Z)(ZG)-E SM567CTP-E SP1604AT7(Z)(ZG) SM567CTP-E SP1604AT8(Z)(ZG)-E SM566KRT-E SP1604AT7(Z)(ZG) SM566KRT-E EER Triple system : SDI-Super Digital Inverter 3-phase Heating Indoor unit type Compact 4-Way Cassette 4-Way Cassette Slim Duct Standard Duct Ceiling High-Wall Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SP1604AT8(Z)(ZG)-E SM564MUT-E SP1604AT7(Z)(ZG) SM564MUT-E SP1604AT8(Z)(ZG)-E SM564UTP-E SP1604AT7(Z)(ZG) SM564UTP-E SP1604AT8(Z)(ZG)-E SM564SDT-E SP1604AT7(Z)(ZG) SM564SDT-E SP1604AT8(Z)(ZG)-E SM566BT-E, SM566BTP-E SP1604AT7(Z)(ZG) SM566BT-E, SM566BTP-E SP1604AT8(Z)(ZG)-E SM567CTP-E SP1604AT7(Z)(ZG) SM567CTP-E SP1604AT8(Z)(ZG)-E SM566KRT-E SP1604AT7(Z)(ZG) SM566KRT-E COP

40 40 Twin, Triple and Double twin system Triple system : DI-Digital Inverter 1-phase Cooling Indoor unit type Outdoor unit name Indoor unit name HP Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% Compact 4-Way Cassette SM1603AT(Z)(ZG)-E SM564MUT-E Way Cassette SM1603AT(Z)(ZG)-E SM564UTP-E Slim Duct SM1603AT(Z)(ZG)-E SM564SDT-E Standard Duct SM1603AT(Z)(ZG)-E SM566BT-E, SM566BTP-E Ceiling SM1603AT(Z)(ZG)-E SM567CTP-E High-Wall SM1603AT(Z)(ZG)-E SM566KRT-E Capacity EER Triple system : DI-Digital Inverter 1-phase Heating Indoor unit type Outdoor unit name Indoor unit name HP Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% Compact 4-Way Cassette SM1603AT(Z)(ZG)-E SM564MUT-E Way Cassette SM1603AT(Z)(ZG)-E SM564UTP-E Slim Duct SM1603AT(Z)(ZG)-E SM564SDT-E Standard Duct SM1603AT(Z)(ZG)-E SM566BT-E, SM566BTP-E Ceiling SM1603AT(Z)(ZG)-E SM567CTP-E High-Wall SM1603AT(Z)(ZG)-E SM566KRT-E Capacity COP Triple system : DI Big 3-phase Cooling Indoor unit type 4-Way Cassette Standard Duct Ceiling High-Wall Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SM2244AT8(Z)(ZG)-E SM804UTP-E SM2244AT7(Z)(ZG) SM804UTP-E SM2804AT8(Z)(ZG)-E SM804UTP-E SM2804AT7(Z)(ZG) SM804UTP-E SM2244AT8(Z)(ZG)-E SM806BTP-E SM2244AT7(Z)(ZG) SM806BTP-E SM2804AT8(Z)(ZG)-E SM806BTP-E SM2804AT7(Z)(ZG) SM806BTP-E SM2244AT8(Z)(ZG)-E SM807CTP-E SM2244AT7(Z)(ZG) SM807CTP-E SM2804AT8(Z)(ZG)-E SM807CTP-E SM2804AT7(Z)(ZG) SM807CTP-E SM2244AT8(Z)(ZG)-E SM806KRT-E SM2244AT7(Z)(ZG) SM806KRT-E SM2804AT8(Z)(ZG)-E SM806KRT-E SM2804AT7(Z)(ZG) SM806KRT-E EER Triple system : DI Big 3-phase Heating Indoor unit type 4-Way Cassette Standard Duct Ceiling High-Wall Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SM2244AT8(Z)(ZG)-E SM804UTP-E SM2244AT7(Z)(ZG) SM804UTP-E SM2804AT8(Z)(ZG)-E SM804UTP-E SM2804AT7(Z)(ZG) SM804UTP-E SM2244AT8(Z)(ZG)-E SM806BTP-E SM2244AT7(Z)(ZG) SM806BTP-E SM2804AT8(Z)(ZG)-E SM806BTP-E SM2804AT7(Z)(ZG) SM806BTP-E SM2244AT8(Z)(ZG)-E SM807CTP-E SM2244AT7(Z)(ZG) SM807CTP-E SM2804AT8(Z)(ZG)-E SM807CTP-E SM2804AT7(Z)(ZG) SM807CTP-E SM2244AT8(Z)(ZG)-E SM806KRT-E SM2244AT7(Z)(ZG) SM806KRT-E SM2804AT8(Z)(ZG)-E SM806KRT-E SM2804AT7(Z)(ZG) SM806KRT-E COP

41 41 Double twin system : DI Big 3-phase Cooling Indoor unit type Compact 4-Way Cassette 4-Way Cassette Slim Duct Standard Duct Ceiling High-Wall Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SM2244AT8(Z)(ZG)-E SM564MUT-E SM2244AT7(Z)(ZG) SM564MUT-E SM2244AT8(Z)(ZG)-E SM564UTP-E SM2244AT7(Z)(ZG) SM564UTP-E SM2804AT8(Z)(ZG)-E SM804UTP-E SM2804AT7(Z)(ZG) SM804UTP-E SM2244AT8(Z)(ZG)-E SM564SDT-E SM2244AT7(Z)(ZG) SM564SDT-E SM2244AT8(Z)(ZG)-E SM566BT-E, SM566BTP-E SM2244AT7(Z)(ZG) SM566BT-E, SM566BTP-E SM2804AT8(Z)(ZG)-E SM566BT-E, SM566BTP-E SM2804AT7(Z)(ZG) SM566BT-E, SM566BTP-E SM2244AT8(Z)(ZG)-E SM567CTP-E SM2244AT7(Z)(ZG) SM567CTP-E SM2804AT8(Z)(ZG)-E SM807CTP-E SM2804AT7(Z)(ZG) SM807CTP-E SM2244AT8(Z)(ZG)-E SM566KRT-E SM2244AT7(Z)(ZG) SM566KRT-E SM2804AT8(Z)(ZG)-E SM806KRT-E SM2804AT7(Z)(ZG) SM806KRT-E EER Double twin system : DI Big 3-phase Heating Indoor unit type Compact 4-Way Cassette 4-Way Cassette Slim Duct Standard Duct Ceiling High-Wall Outdoor unit name Indoor unit name HP Capacity Rated min-max Power consumption (kw) (kw) (kw) 100% 80% 50% SM2244AT8(Z)(ZG)-E SM564MUT-E SM2244AT7(Z)(ZG) SM564MUT-E SM2244AT8(Z)(ZG)-E SM564UTP-E SM2244AT7(Z)(ZG) SM564UTP-E SM2804AT8(Z)(ZG)-E SM804UTP-E SM2804AT7(Z)(ZG) SM804UTP-E SM2244AT8(Z)(ZG)-E SM564SDT-E SM2244AT7(Z)(ZG) SM564SDT-E SM2244AT8(Z)(ZG)-E SM566BT-E, SM566BTP-E SM2244AT7(Z)(ZG) SM566BT-E, SM566BTP-E SM2804AT8(Z)(ZG)-E SM566BT-E, SM566BTP-E SM2804AT7(Z)(ZG) SM566BT-E, SM566BTP-E SM2244AT8(Z)(ZG)-E SM567CTP-E SM2244AT7(Z)(ZG) SM567CTP-E SM2804AT8(Z)(ZG)-E SM807CTP-E SM2804AT7(Z)(ZG) SM807CTP-E SM2244AT8(Z)(ZG)-E SM566KRT-E SM2244AT7(Z)(ZG) SM566KRT-E SM2804AT8(Z)(ZG)-E SM806KRT-E SM2804AT7(Z)(ZG) SM806KRT-E COP

42 42 Super Digital Inverter & Digital Inverter - Controllers & Accessories Parts Name Model Name Applied Model Features Wired remote controller RBC-AMT32E All indoor units Standard type RBC-AMS41E All indoor units Remote controller with weekly timer RBC-AMS51E-ES/-EN All indoor units Remote controller with LCD display with backlight Simple wired remote controller RBC-AS41E All indoor units With Simplified control Wireless remote controller kits Remote controller kits RBC-AX32U(W)/(WS)-E 4-Way Cassette type Integral receiver type RBC-AX33CE Ceiling type Integral receiver type TCB-AX32E2 All indoor units Standalone receiver type TCB-EXS21TLE Use with wired remote controller Remote controller with schedule timer TCB-CC163TLE2 Used with wired remote controller / Central remote controller TCB-SC642TLE2 All indoor units Central remote controller BMS-CM1280TLE All indoor units Compliant manager On-Off controller combined with the weekly timer TCC-Link* TCB-PCNT30TLE2 All indoor units except High-wall type Use with Remote controller kit * : TCC-Link Adaptor for Super Digital Inverter & Digital Inverter units. Indoor unit controllers 4-Way Cassette type Indoor unit Parts Name Model Name Applied Model Remarks Compact 4-Way Cassette type Ceiling panel RBC-U31PGP(W)-E, RBC-U31PGP(WS)-E Fresh air inlet box TCB-GB1602UE Use with TCB-GFC1602UE Fresh air filter chamber Auxiliary fresh air flange Spacer for height adjustment Air discharge direction kit Ceiling panel Auxiliary fresh air flange TCB-GFC1602UE TCB-FF101URE2 TCB-SP1602UE TCB-BC1602UE RBC-UM11PG(W)E TCB-FF101URE2 RAV-SM***4UTP-E RAV-SM***4MUT-E Slim Duct type Auxiliary fresh air flange TCB-FF101URE2 RAV-SM***4SDT-E Standard Duct type Concealed Duct High Static Pressure type Ceiling type Spigot shaped flange High-efficiency filter 65 High-efficiency filter 90 Long life prefilter Filter chamber Drain pump kit Drain pump kit Elbow piping kit Optional connecting kit TCB-SF56C6BE TCB-SF80C6BE TCB-SF160C6BE TCB-UFM3DE TCB-UFH7DE TCB-PF3DE TCB-FCY100DE TCB-DP32DE TCB-DP31CE TCB-KP13CE TCB-KP23CE TCB-PCUC1E RAV-SM406BT-E, RAV-SM456BT-E, RAV-SM566BT-E, RAV-SM406BTP-E, RAV-SM456BTP-E, RAV-SM566BTP-E RAV-SM806BT-E, RAV-SM806BTP-E RAV-SM1106BT-E, RAV-SM1406BT-E, RAV-SM1606BT-E, RAV-SM1106BTP-E, RAV-SM1406BTP-E, RAV-SM1606BTP-E RAV-SM***2DT-E RAV-SM***7CTP-E Indoor unit accessories Use with TCB-FCY100DE Use with TCB-KP13CE, TCB-KP23CE Parts Name Model Name Type Branch kit Application control RBC-TWP30E2 RBC-TWP50E2 RBC-TWP101E "1:2" RBC-TRP100E "1:3" RBC-DTWP101E "1:4" TCB-PCOS1E2 TCB-KBOS1E Super Digital Inverter 1-phase, 3-phase model and Digital Inverter 1-phase model Twin system of Dl Big model Triple system of Super Digital Inverter 3-phase model, Digital Inverter 1-phase model and DI Big model Double twin system of DI Big model Super Digital Inverter 1-phase model

43 Remote controllers 43 Standard wired remote controller can be connected to a single indoor unit or a group of up to 8 indoor units. Power save operation limits the greatest current value.the remote controller allows error to be displayed while the protective device works or a error occurs. Standard Remote controller RBC-AMT32E Wired remote controller with clock display and a built in 7-day timer function, possible to program 8 functions for each day of the week. *The following items can be set in program: operation time, operation start/stop, operation mode, temperature setting, restriction on button operation Remote controller with weekly timer (7-day timer function) RBC-AMS41E Lite-Vision plus Remote Controller RBC-AMS51E-ES RBC-AMS51E-EN Wired remote controller with a built in 7-day timer-featuring a new multi-language, LCD display with backlight, energy saving options and a return back function. Possibility to set and display the room name to easily set-up and monitor the working parameter. New modern and desirable controller design with menu driven display. Save mode by schedule timer to optimise energy consumption. Room temperature display always available. Two Hot Keys (F1, F2) for easy operation of air conditioner functions. Easy to read layout including display of indoor unit model name and serial number. Built-in backup power. Settings are kept in memory up to 72 hours in case of power failure. Remote TA sensor available in controller. Can be connected to a single indoor unit or a group of up to 8 indoor units. Simple wired remote controller RBC-AS41E Schedule timer TCB-EXS21TLE ON-OFF controller TCB-CC163TLE2 Simple wired remote controller can be connected to a single indoor unit or a group of up to 8 indoor units. Start/Stop Temperature setting Air flow changing Check code display Schedule timer mode 6 programmings per day Enabling 8 groups to be programmed A maximum of 64 indoor units can be controlled A maximum of 100 hours back-up power supply Weekly timer mode 7 types of weekly schedule and 3 programmings per day Individual control of up to 16 indoor units. Setting of simultaneous ON/OFF 3 times per day combined with the weekly timer. Wireless remote controller kit Start/Stop Changing mode Temperature setting Air flow changing Timer function Either ON time or OFF time or CYCLIC can be set how many 30 min. later ON or OFF is operated. Control by 2 remote controllers is available. Two wireless remote controllers can operate one indoor unit. The indoor unit can then be operated separately from the two different locations. Check code display RBC-AX32U(W)/(WS)-E Integral receiver (For 4-way cassette) RBC-AX33CE Integral receiver (For ceiling) TCB-AX32E2 Sensor unit; Stand alone receiver (For 4-way cassette, Compact 4-way cassette (600 x 600), Ceiling, Duct type, High-wall) Central remote controller TCB-SC642TLE2 Individual control for max. 64 indoor units divided into 1 to 4 zone (Up to 16 indoor units for each zone) Up to 16 outdoor header units are connectable 4 types of central control settings to inhibit individual operation by remote controller can be selected Usable with other central control devices (Max. 10 devices in one control circuit) Two control mode selectivity (Central controller mode ) Remote controller mode Setting of simultaneous ON/OFF 3 times per day combined with the weekly timer. Central remote controller BMS-CM1280TLE Operation Individual operation of 128 indoor units available Return Back Operation Weekly Schedule Operation* (ON/OFF) * Schedule timer necessary Monitoring Zone setting (64 zones x 2) Individual unit operation mode operation restriction Alarm display Control input Status output

44 44 SPI Energy saving and high reliability. By achieving both goals, SPI provide complete customer satisfaction. SPI is an energy-saving air conditioner for light commercial use that was designed to meet our customers needs. SPI is able to reduce the refrigerant volume and achieve a high Energy Efficiency Ratio (EER). Due to its compact size, the unit can even be installed in small shops. In addition, the unit is equipped with various standard features, such as an AUTO restart function for blackouts,to ensure stable operation. SPI is a new type of air conditioner which, thanks to the above advantages can be used. High efficient performance SPI gives you high cooling performance with low power consumption. SPI is equipped with an inverter, and achieves a high part-load EER value. * 4-Way Cassette type New compressor Toshiba specially developed new twin rotaty compressor for SPI. Toshiba realized 4 and 5 HP capacity by maintaining compact size.

45 45 Light-weight and compact for easy installation SPI employs a newly developed compressor, and weighs only 48 kg. Light-weight, compact, and easy to carry and install. Automatic restart even after a blackout After the blackout ends, SPI restarts automatically with the settings used before the blackout. The settings do not need to be reconfigured using the remote controller. 1. Protection circuit 2. Sealed inverter box Protected center part SPI has 4 advantages to maintain stable operation. 1. Equipped with a function that detects miswiring of the power supply and protects the circuit. 2. Almost sealed inverter box to prevent entering of sand and dust-prevents malfunction due to outdoor conditions. 3. Steady operation-maintains stable operation under higher power supply (380V+20%) 4. Silk screen coating for the PC board-prevents malfunction due to sand and dust. Outdoor units combinations Equivalent HP 4HP 5HP Model name RAV-TE1001A8 (-T, -ID, -SG) RAV-TE1251A8 (-T, -ID, -SG) 4-Way Cassette type RAV-SE1001UP (-T, -ID) RAV-SE1251UP (-T, -ID) Ceiling type RAV-SE1001CP (-T) RAV-SE1251CP (-T)

46 46 Ceiling type Smooth Curve for pliant Shape All-new chassis and new rounded design, This new models have been developed in response to customers needs for ceiling units that better match their room interiors. New Designed Wide Flap RAV-SE 1CP (-T) The airflow angle is automatically set to the most suitable setting according to your needs, an automatic swing mode enables airflow to reach all areas of the room to create a comfortable ambience. Option** Previous model New model Wireless remote controller kit RBC-AX33CE Option** 30% Extension New Drain pump kit available as an option Wired remote controller RBC-AMT32E The Drain pump kit makes draining easier. Anti-bacterial glass built into Drain Pump Kit helps reduce mould formation. 4-Way Cassette type The wide air flow in all direction RAV-SE 1UP (-T, -ID) Panel Wide flow louver type Compact sizing Compact size especially in height (256 mm), new slimmer chassis offers wide range of installation opportunities to customer. RBC-U31PGXP(W)-IN Standard supply* 325 mm 256 mm For branch duct knockout hole Wireless remote controller Receiving part Option** Branch duct* for 4-way air discharge cassette type * The branch duct and the air outlet unit are local supply / Please seal the air outlet of branching side with the air discharge direction kit. Wired remote controller RBC-AMT32E * Included with indoor unit ** Available as an option.

47 47 SPI Ceiling type 4-Way Cassette type Outdoor unit TE1001A8 TE1251A8 TE1001A8 TE1251A8 Indoor unit SE1001CP SE1251CP SE1001UP SE1251UP Cooling* 1 Power supply Capacity kw Range, min-max kw Power consumption kw EER (Energy Efficiency Ratio) Capacity 100% Capacity 80% Capacity 50% phase 50Hz V Performance data Physical data Indoor unit Ceiling type 4-Way Cassette type SE1001CP SE1251CP SE1001UP SE1251UP Standard air flow (H/M/L) m 3 /h 1410/1020/ /1350/ /1530/ /1530/1230 Sound pressure level (H/M/L) db(a) 50/46/39 51/47/40 47/44/39 48/44/39 Sound power level (H/M/L) db(a) /59/54 63/59/54 Main unit dimensions (H/W/D) mm 235/1269/ /1586/ /840/ /840/840 Weight kg Physical data Equivalent HP 4HP 5HP Outdoor unit TE1001A8 TE1251A8 Power supply 3-phase 50Hz V Compressor type DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / / 5 MML-AP***4NH-E Max. pipe total length m Maximum height difference m Outer dimensions (H/W/D) mm 890/900/ /900/320 Weight kg Standard air flow (Fan unit) m 3 /h Sound pressure level db(a) Sound power level db(a) Operating range C 15~46 Indoor unit controllers Parts Name Model Name Applied Model Indoor unit accessories Indoor unit Parts Name Model Name RBC-AMT32E All indoor units Wired remote controller RBC-AMS41E All indoor units RBC-AMS51E All indoor units Simple wired remote controller RBC-AS41E All indoor units Wireless remote controller kits RBC-AX33CE Ceiling type Schedule timer TCB-EXS21TLE Use with RBC-AMT32E Ceiling type Drain pump kit Elbow piping kit Optional connecting kit TCB-DP31CE TCB-KP13CE TCB-KP23CE TCB-PCUC1E

48 48 RAV-SE***1CP (-T) Z A D C B Z view Spacerequired forinstallation and servicing Hanging bolt SE1001CP SE1251CP Model RAV- A B C D Within 50 Ceiling surface Unit 250 or more 250 or more (Front side to be positioned horizontally) (Unit:mm) Options TCB-KP13CE, TCB-KP23CE Elbow piping RBC-AX33CE Wireless remote controller TCB-DP31CE Drain pump kit TCB-PCUC1E Optional connecting kit

49 49 RAV-SE***1UP (-T, -ID) Electric parts box Celling Ceiling bottom surface Knockoutfor freshairintake intake φ100 Z Zview *( ): SM1104 to SM Z Hanging bolt pitch Panel external dimension B Hanging bolt pitch Panel external dimension Hanging bolt M10 or (procured by locally) Drain pipe connection port (Material: PP) For branch duct Knockout square hole 860to Ceiling open dimension ension Ceiling open dimension 860 to910 ension Refrigerant pipe connecting port (Liquid side) Refrigerant pipe connecting port (Gas ide) C D 300orless A Bottom faceofceiling Ceiling Stand-up 661orless Stand-up 850orless Bottom face of ceiling Ceiling Ceiling panel (sold separately) Drain Drain standing-up size For branch duct Knockout square hole Spacerequiredforinstallation installation and servicing and servicing 1000 ormore 1000 orm more 15 or more Bottom face of ceiling 15 or more m ore Take-in port of wiring Model RAV- A B SE1001U SM564UTP-E SE1251U SM804UTP-E SM1104UTP-E, SM1404UTP-E, SM1604UTP-E C D or or more more (Unit:mm) Options TCB-FF101URE2 TCB-GFC1602UE Fresh air inlet box TCB-GB1602UE Air discharge direction kit TCB-BC1602UE Spacer for height adjustment Spacer for height adjustment TCB-SP1602UE Ceiling panel RBC-U31PGXP(W)-IN Air discharge parts A Packing A Air discharge parts B Packing B Refrigerant piping side Drain piping side Air discharge parts C Packing B Air inlet grille

50 50 SDI Super Digital Inverter 1.5-2HP & DI Digital Inverter 2-3HP : Outdoor unit drawings Drain hole(dia. 25) A legs Drain hole (2-dia. 20x88 long hole) 320 (Long hole pitch For anchor bolt) 306 dia.hole pitch B legs dia U-shape hole (For dia.8-10 anchor bolts) Refrigerant pipe connecting port (dia flare at gas side) Refrigerant pipe connecting port (dia. 6.4 flare at liquid side) 8-dia. 6 hole For fixing outdoor unit 27 2-dia. 11xL14 long hole (For dia anchor bolts) charge port 342 Earth terminal Discharge guard Discharge guide mounting hole (4-dia.4.5 embossing) Space required for for installation and servicing ser icing 2-dia. 11x14 U-shape hples (For dia anchor bolt) or more 600 Suction port or more Discharge port 300 or more ( inimum M distance up to w all) 500 or more Discharge port 2-dia. 11x14 long hole (For dia.8-10 anchor bolt) R15 2-dia. 6 hole Product external line dia. 11x14 U-shape hole Details of A legs 320 dia. 11x14 U-shape hole Details of B legs Product external line 2-dia. hole R15 (Unit: mm) mm)

51 51 SDI Super Digital Inverter 3HP & DI Digital Inverter 4HP: Outdoor unit drawings Air inlet port Drain hole(dia. 25) B legs Air inlet port Drain hole(dia. 20x88) Air outlet port A legs Mounting bolt hole (dia. 12x17 long hole) Details ofa legs Mounting bolt (dia. 12x17 U-shape hole) Details of B legs Refrigerant pipe connecting port (dia. 9.5 flare at liquid side) Refrigerant pipe connecting port (dia flare at gas side) Knockout for downward piping Z views 1 2 Name Refrigerant piping hole Indoor/Outdoor unit connecting wire inlet hole Power supply inlet holed Note ia. 38 Knockout hole (Unit: mm)

52 52 SDI Super Digital Inverter 4-6HP & DI Digital Inverter 6HP : Outdoor unit drawings Air inlet port Air inlet port Drain hole (Ø25) B legs Mounting bolt hole (Ø12 17 long hole) Drain hole (Ø28 88) Air outlet 383 port A legs Details of A legs Details of B legs 320 Mounting bolt hole (Ø12 17 U-shape hole) Refrigerant pipe connecting port (Ø9.5 flare at li uid q side) Refrigerant pipe connecting port (Ø15.9 flare at gas side) Name Refrigerant piping hole Indoor/Outdoor unit connecting wire inlet hole Power supply inlet hole Note Ø38 Kockout hole Z views iews Knockout for downward piping (Unit: (Unit mm) )

53 53 DI Big 8-10HP: Outdoor unit drawings Knockout (for drain) Drain hole (Ø28 x 88 bearing hole) Drain hole (Ø25 bearing hole) Mounting bolt hole (Ø12 x 17 long hole) Air inlet port B legs Air inlet port Knockout (for drain) Air outlet A legs Details of A legs Mounting bolt hole (Ø12 x 17 U-shaped hole) Details of B legs * Refrigerant pipe connecting port (liquid side) Refrigerant pipe connecting port (gas side) Z views Knockout for downward piping * Name Note a Refrigerant piping hole Indoor/Outdoor unit connecting wire inlet hole b Power supply inlet holeø 38 Knockout hole Piping Connection Aperture Radius Connection Piping Radius LiquidG as LiquidG as Since the connection diameter of the ball valve in the outdoor unit main body is Ø19.1, use the attached coupling pipe when performing maintenance. (Unit: mm)

54 54 SPI: Outdoor unit drawings (Unit: mm)

55 55 Installation and the use of refrigerants not specified by Toshiba Carrier Corporation Toshiba refrigeration and air-conditioning units are designed and manufactured on the assumption that the product is used with a specific refrigerant suitable for each unit. We have recently seen some cases where the type of refrigerant used is different from the one originally installed in the product. Such actions may cause mechanical defects, malfunctions, failures and in some cases result in a serious safety issue. Therefore do not install any refrigerant other than the one specified by Toshiba Carrier Corporation for its respective products. The type of the refrigerant used for each of our products is shown in the accompanying owners manual, or on the product label attached on the product itself. Toshiba Carrier Corporation shall not assume any liability for failures, malfunctions or safety in its products if the refrigerant used is different from the one specified. SAFETY PRECAUTIONS For operation: Before use, read through the operating instructions to ensure proper use. Concerning the purpose for which the air conditioners are to be used The air conditioners presented in this catalogue are air conditioning/heating units to be used solely by general consumers. Do not use these air conditioners for special applications such as for the storage of food items, animals, plants, precision machines or works of art. Doing so may degrade the quality of the items. Do not use these air conditioners for air-conditioning applications in vehicles or ships. Doing so may cause water and/or power leakages. Precautions for using air conditioners Concerning the automatic defrosting unit When the outdoor air temperature drops, frost may form on the heat exchanger of the outdoor unit. In such cases, the automatic defrosting unit will be activated, and it will take 5 to 8 minutes for the heating operation to be restored. Concerning the air conditioner's operating conditions and their selection (1) Avoid using the air conditioner in the following locations. Locations with acidic or alkaline atmospheres (locations at which highly acidic or alkaline air is directly drawn in, such as in hot springs areas from which sulfur gases are given off, or where chemicals, vinegar, exhaust air from burners, etc., are given off) The heat exchangers and other parts may become corroded. Locations with atmospheres filled with coolant or other machine oil or steam exhaust (such as at food preparation factories or machine plants). The heat exchangers may corrode; frost may form as a result of heat exchanger malfunction; air conditioner operating performance may be compromised or condensation may form as a result of clogged filters; plastic parts may incur damage; heat-insulation materials may become separated, etc. (2) Before using an air conditioner in any of the following locations, consult with your dealer or a qualified contractor. Locations where vapors from edible oils are given off (such as in bakeries or kitchens and restaurants that use edible oils)...the air conditioner's operating performance may be compromised or condensation may form as a result of clogged filters, and the plastic parts may incur damage. In line with the prevailing conditions, take countermeasures such as tailoring the installation conditions in accordance with the conditions, using air conditioners designed for kitchens or oil guard filters, etc. Locations with disinfectant-induced chlorine atmospheres (water tanks, etc.) The metal parts in the heat exchangers, motors, etc., may become corroded. Locations with high salinity (coastal areas, etc.) Corrosion may occur so use outdoor units specifically designed to withstand exposure to salt. Locations where power is supplied from independent power generators. The power line frequency and/or voltage may fluctuate, possibly causing the air conditioner to malfunction. Locations where high frequencies or electrical noise is generated (from high-frequency welders used for vinyl welding and processing, high-frequency therapeutic devices used for thermotherapy, etc.) The electronic components may be adversely affected, possibly causing the air conditioner to malfunction. Locations where electronic equipment is installed. Electrical noise may adversely affect the operation of the electronic equipment. (3) Concerning use in locations with high ceilings In locations with high ceilings, use of circulators for improving the temperature distribution during heating is recommended. (4) Concerning use in high-humidity environments When the ceiling-recessed type of indoor unit is installed in a location, such as those described below, and it is very hot and humid inside the ceiling, condensation may form on the external surfaces of the indoor unit and drip down. In such cases, add external heat-insulating materials. Locations such as food preparation sites in which the areas above the ceilings are hot and humid Locations in which outside air is drawn in and routed above the ceiling Above ceilings with a slate roof or tiled roof overhead (5) Even when an air conditioner is shut down, it will still consume a small amount of power to protect the unit. If the air conditioner will not be used for a prolonged period, turn OFF the main switch (ground fault circuit breaker). However, before the unit is to be used again, turn ON the main switch (ground fault circuit breaker) for at least 12 hours in order to prevent trouble.

56

Inverter Air Conditioning for Light Commercial Use

Inverter Air Conditioning for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation

More information

Air Conditioning for Small and Medium-size Buildings

Air Conditioning for Small and Medium-size Buildings Air Conditioning for Small and Medium-size Buildings Defining a HIGHER standard The all-new MiNi-SMMS air conditioner lineup lets you cool or warm as many as 12 *1 rooms with a single system. Outdoor units

More information

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and 1 Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and cost-effective, Toshiba aims at the heart of growing

More information

Air Conditioning For Large Buildings

Air Conditioning For Large Buildings Air Conditioning For Large Buildings Index Introduction 3 Industry leading energy savings 6 New smart & sensitive VRF control 10 Industry leading layout flexibility 14 Other features 18 Outdoor units Outdoor

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world s leading technology companies, MITSUBISHI ELECTRIC

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience

More information

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

2015 / 16. price list. Airconditioning systems

2015 / 16. price list. Airconditioning systems 2015 / 16 price list Airconditioning systems TERMS OF BUSINESS General As far as nothing else has been declared, the general terms of business and the agreed purchase conditions including the sales discounts

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE

More information

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units SALES BULLETIN Key Features 1. Chassis completely re designed 2. Increased product range, now includes 6HP model 3. New features to enable easy installation a. Easy access hanger b. Easier wiring connections

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW utopia DC Inverter 7kW-14kW G8 5kW-25kW Split Systems Contents Company profile 4 Product range overview 6 Features and benefits 8 DC Inverter 12 Utopia G8 24 Utopia centrifugal 40 Total heat exchanger

More information

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73

Contents. Part 1 General Information... 1. Part 2 Outdoor Units... 9. Part 3 Installation... 50. Part 4 Troubleshooting 73 MCAC-VTSM-2013-03 R410a Full DC Inverter Mini VRF Contents Part 1 General Information... 1 Part 2 Outdoor Units... 9 Part 3 Installation... 50 Part 4 Troubleshooting 73 Part 5 Control System... 100 Manufacture

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Multi Air Conditioning System for Buildings

Multi Air Conditioning System for Buildings Multi Air Conditioning System for Buildings 6, Suenaga, Takatsuku, Kawasaki 238502, Japan http://www.fujitsugeneral.com/ ISO 900 ISO 400 ISO 900 ISO 400 Certified number : 0 00 89394 Certified number :

More information

NEW 3-PIPE ECOi MF2 SERIES

NEW 3-PIPE ECOi MF2 SERIES NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

Pioneer in sustainability

Pioneer in sustainability Pioneer in sustainability Over 100 years ago Carrier helped pioneer a new industry, and in the last two decades we have pioneered environmentally sensitive products with a reduced impact on the environment.

More information

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

innovative comfort solutions

innovative comfort solutions engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal

Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal Utopia Split Systems Models Utopia ES (7.1-14 kw) Utopia IVX (7.1-30 kw) Utopia DC Inverter (5-14 kw) Utopia Fixed Speed (6.3-12.5 kw) Utopia Centrifugal (12.5-25 kw) Contents Company Profile 4 Utopia

More information

FBQ. DC Duct Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY Designed and built with the commitment to high-quality craftsmanship you expect from American Standard, our ductless

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

ECO-AIR AIR CONDITIONING www.northamericanhvac.com

ECO-AIR AIR CONDITIONING www.northamericanhvac.com INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

FTXS. Wall Mount Heat Pump or Cooling Only

FTXS. Wall Mount Heat Pump or Cooling Only FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both

More information

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4. AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice

More information

Versati Air to Water Heat Pump

Versati Air to Water Heat Pump Versati Air to Water Heat Pump VERSATI DC Inverter Multifunctional Air To Water Heat Pump Nowadays, people are increasingly focusing on heating costs as well as environmental issues. Traditional heating

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HEATER SYSTEM 1. Heater System A: GENERAL A semi-center type integrated air conditioning unit is used, where a high performance heater core and an evaporator core

More information

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair FTXS-L Series FDXS-L Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair FTXS-L Series FDXS-L Series Cooling Only Indoor Unit FTXS30LVJU

More information

Samsung Room Air Conditioning

Samsung Room Air Conditioning Samsung Room Air Conditioning Air Conditioning Solutions from a Trusted Brand At the heart of family living is the home, a place full of special moments and wonderful memories where families live and

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

Residential and Light Commercial Air Conditioning Systems

Residential and Light Commercial Air Conditioning Systems Residential and Light Commercial Air Conditioning Systems Beautifully Designed to Save Engineering and Specifications Guide Beautifully Designed to Save As air conditioners have reached high levels of

More information

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort Heat Pump Product Brochure 2015/2016 Premier Series Hi-Wall Split Systems Everyday Comfort Everyday Innovation We design with you in mind. You ll find that Haier Heat Pump units are quiet, efficient and

More information

LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible

LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible LG Duct-Free Split Systems Product Overview LG comfort solutions that you never thought possible TABLE OF CONTENTS Company Introduction Introduction 4 Duct Free System Introduction 6 Key Features 8 Duct-Free

More information

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series Internal Use Only http://biz.lgservice.com System Indoor Unit R410A SERVICE MANUAL R410A MODEL : ARNU Series URNU Series CAUTI Before Servicing the unit, read the safety precautions in General SVC manual.

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6. TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM

More information

FHQ. Ceiling Suspended Heat Pump or Cooling Only

FHQ. Ceiling Suspended Heat Pump or Cooling Only FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this

More information

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER IN-CEILING CASSETTE Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms. INVERTER TECHNOLOGY PFC Control in Power Input DC Inverter

More information

PRODUCT CATALOG. Indoor Units

PRODUCT CATALOG. Indoor Units PRODUCT CATALOG Indoor Units Life s Good! From installation to maintenance, LG runs more than 60 global air conditioning academies, each provides training for air conditioning professionals. What is LG?

More information

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit Ref.-No. SMMS02-AE-10-05 Indoor unit 4-way ceiling cassette MMU-AP0091H, AP0121H, AP0151H, MMU-AP0181H, AP0241H, AP0271H, MMU-AP0301H, AP0361H, AP0481H MMU-AP0561H 2-way ceiling cassette MMU-AP0071WH,

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

VRF CATALOGUE HEAT PUMP & HEAT RECOVERY. for Europe. Variable Refrigerant Flow System

VRF CATALOGUE HEAT PUMP & HEAT RECOVERY. for Europe. Variable Refrigerant Flow System VRF Variable Refrigerant Flow System CATALOGUE HEAT PUMP & HEAT RECOVERY for Europe Fujitsu General have been developing and manufacturing high quality and energy efficient products for more than 35 years.

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Residential and Light Commercial Air Conditioning Systems

Residential and Light Commercial Air Conditioning Systems Residential and Light Commercial Air Conditioning Systems Beautifully Designed to Save Engineering and Specifications Guide Beautifully Designed to Save As air conditioners have reached high levels of

More information

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant

More information

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4) room air conditioners Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4) Contents Company profile 4 Product range overview 6 Standards and quality certificates 8

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS POER, FLEXIBILITY, RESIDENTIAL Carrier presents the new line of multi-split systems A complete and flexible range designed to meet every residential and light

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION

More information

GREE, MAKING BETTER AIR CONDITIONERS

GREE, MAKING BETTER AIR CONDITIONERS GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI Add:Jinji RD.Qianshan Zhuhai 519070,Guangdong,China Tel: (+86-756)8614883 Fax: (+86-756)8627140 Email: [email protected] http://www.gree.com.cn Heat Pump Water Heater

More information

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90 6 Air Movement Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners Pg 83 84 85 85 86 88 89 90 83 Air Movement JKI Heaters Aurora Bathroom Heater Quartz 2

More information

PLA. Advancements in PLA series improve style and performance for ensured indoor comfort. 4-way Ceiling Cassette. Wide Airflow.

PLA. Advancements in PLA series improve style and performance for ensured indoor comfort. 4-way Ceiling Cassette. Wide Airflow. 13 4-way Ceiling Cassette PLA SERIES Advancements in PLA series improve style and performance for ensured indoor comfort Wide Air Wide-angle outlets distribute air to all corners of the room, ensuring

More information

LG AIR CONDITIONERS 2014 Ducted Split System

LG AIR CONDITIONERS 2014 Ducted Split System Australia Pty Ltd. New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : 02-8805-4000 FAX : 02-8805-4248 AUS-DU1309 Queensland 23 Terrace Place MURARRIE QLD 4172 PH : 07-3908-9000

More information

AIR-CONDITIONER SPLIT TYPE

AIR-CONDITIONER SPLIT TYPE FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series Internal Use Only http://biz.lgservice.com System Indoor Unit R410A SERVICE MANUAL R410A MODEL : ARNU Series URNU Series CAUTI Before Servicing the unit, read the safety precautions in General SVC manual.

More information

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type K-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type K-Series Cooling Only Indoor Unit FTXN09KEVJU

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

How to choose a heat pump and use it wisely

How to choose a heat pump and use it wisely How to choose a heat pump and use it wisely Contents How does a heat pump work? 2 Insulating your home 3 Heat loss in the home Not all heat pumps are created equal 4 Choosing a heat pump 4 Choosing by

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW

More information

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT UP TO 15 SEER Performance MINI-SPLIT SYSTEM UNITS AIR CONDITIONING AND HEAT PUMPS COMPLETE ROOM COMFORT WITH EASY-TO-USE REMOTE CONTROL HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT The Goodman brand offers

More information

FCQ. Roundflow Cassette Heat Pump or Cooling Only

FCQ. Roundflow Cassette Heat Pump or Cooling Only FCQ Roundflow Cassette Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FCQ roundflow cassette SkyAir systems are ideal for open plan applications where variances in temperature and airflow

More information

U-MATCH Air Conditioners. Service Manual. T1/R410a/50Hz

U-MATCH Air Conditioners. Service Manual. T1/R410a/50Hz U-MATCH Air Conditioners Service Manual T1/R410a/50Hz GREE ELECTRIC APPLIANCES INC. OF ZHUHAI 1 CONTENTS PRODUCT...2 1 MODELS LIST...2 1.1 Outdoor Unit...2 1.2 Indoor Unit...3 2 NOMENCLATURE...4 3 FUNCTION...5

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

2 NOMENCLATURE 3 FUNCTION 4 PRODUCT DATA

2 NOMENCLATURE 3 FUNCTION 4 PRODUCT DATA CONTENTS PRODUCT... 2 1 MODELS LIST... 2 1.1 Outdoor Unit... 2 1.2 Indoor Unit... 3 2 NOMENCLATURE... 4 3 FUNCTION... 4 4 PRODUCT DATA... 5 4.1 Product Data at Rated Condition... 6 4.2 Operation Range...

More information

Central Air Conditioner

Central Air Conditioner Central Air Conditioner USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL AIR CONDITIONER NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME

More information

Development and testing of a multi-type air conditioner without using AC inverters

Development and testing of a multi-type air conditioner without using AC inverters Energy Conversion and Management 46 (2005) 373 383 www.elsevier.com/locate/enconman Development and testing of a multi-type air conditioner without using AC inverters Shih-Cheng Hu *, Rong-Hwa Yang Department

More information

technology innovation, comfort for your home. The perfect blend of

technology innovation, comfort for your home. The perfect blend of The perfect blend of innovation, & technology comfort for your home. Air conditioning for your home is all about comfort. No matter what Australia s harsh climate can dish out. From summer scorchers to

More information

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires

More information

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY Trane Ductless Systems Get comfortable with a smart solution. Trane Ductless Systems. A smart solution for efficient comfort, where and when you need it. Trane has a tradition of quality lasting more than

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

WINDOW ROOM AIR CONDITIONER

WINDOW ROOM AIR CONDITIONER WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6 TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

LOCAL AIR-CONDITIONERS

LOCAL AIR-CONDITIONERS LOCAL AIR-CONDITIONERS Local air-conditioners Compact Design Split Design Compact Air-Conditioner Quality with systems REMKO THE CUSTOMER-ORIENTED SYSTEM SUPPLIER FOR THE WHOLE YEAR THROUGH From the development

More information