N+1 Redundancy System. XSSR-VYPx-2502

Size: px
Start display at page:

Download "N+1 Redundancy System. XSSR-VYPx-2502"

Transcription

1 N+1 Redundancy System XSSR-VYPx-2502 Version Date Product covered Subjects A 09/08/2016 XSSR-VYPx-2502 First version Confidentiel TeamCast Page 1/24

2 TABLE OF CONTENT 1. INTRODUCTION Purpose Audience Overview Covered products Associated documentations Architecture XSSR-DExx-1992 switching unit Output redundancy unit: ASI interfaces Input redundancy unit: L-Band signals Input redundancy unit: IF-Band signals CPU Module Vyper Satellite modulators Complete detailed system Software Configuration Vyper Satellite Modulators General panel Config panel Profiles panel Alarm panel XSSR-DExx-1992 Switching Unit System setup Switching actions TRAC Setup IP Monitor Data Backup Operation XSSR-DExx-1992 Modes of operation Local Mode Remote Mode Auto Mode Nominal State Failure State Maintenance operation Support contacts...24 Confidentiel TeamCast Page 2/24

3 TABLE OF FIGURES Figure 1: 1+1 redundancy system... 6 Figure 2: XSSR-DExx-1992 front panel... 7 Figure 3: rear panel of the redundancy switching unit... 7 Figure 4: ASI signal module... 8 Figure 5: Output redundancy unit... 8 Figure 6: L-Band switching module... 9 Figure 7: L-Band switching modules... 9 Figure 8: IF-Band switching module Figure 9: CPU module Figure 10: Vyper Front Panel Figure 11: Vyper Rear Panel Figure 12: N+1 redundancy wiring diagram Figure 13: General panel of Main modulator Figure 14: Profiles panel of the backup modulator Figure 15: Alarms Panel of the main modulators Figure 16: XSSR-DExx-1992 Info Panel Figure 17: XSSR-DExx-1992 System Setup Figure 18: XSSR-DExx-1992 Switching Actions Figure 19: XSSR-DExx-1992 TRAC setup Figure 20: XSSR-DExx-1992 IP Monitor setup Figure 21: XSSR-DExx-1992 Data Backup Figure 22: XSSR-DExx-1992 Nominal State Figure 23: XSSR-DExx-1992 Failure State Confidentiel TeamCast Page 3/24

4 1. INTRODUCTION 1.1 Purpose The topic of this document is to present the way to manage the N+1 redundancy system for the Vyper satellite modulators. The scenario described in this document is focused on the management of the ASI inputs and RF outputs of the modulators. TeamCast proposes a simple & efficient solution: a local switch process and a very fast switching time to be the best transparent as possible. 1.2 Audience This document has been written for customers who have to use, to integrate and to install the redundancy solution for the Vyper Satellite modulators. Some chapters require some prerequisite knowledge in electronics and in SNMP standard. 1.3 Overview Teamcast proposes a N+1 switching system based on the DEV switching unit. One backup modulator can protect up to 8 modulators in a standalone mode. However, a Network Manager System (NMS) can be added to have a global overview of the redundancy system behavior, to monitor the system. This NMS is not mandatory to control the switch process from MAIN to BACKUP modulator. 1.4 Covered products Product family Product references Type Vyper XSSR-VYPx U rack DVB-S/DSNG/S2/S2X IF and L-Band outputs modulator, Confidentiel TeamCast Page 4/24

5 1.5 Associated documentations [D1] MPD , XSSx-VYPx-2502 User Manual [D2] DG , XSSx-VYPx-2502 Developers Guide Confidentiel TeamCast Page 5/24

6 3. Architecture The minimum required to setup the standalone N+1 redundancy system below is: 1 switching unit, N+1 Vyper Satellite modulators, N main and 1 backup, ASI, RF and Ethernet cables. Figure 1: 1+1 redundancy system A dedicated LAN (Ethernet) connection is done between the N+1 modulators and the switching unit. All these elements could be connected to a supervisor (Network Management System) to have a remote overview of the system. This solution is able to protect up to 8 modulators in IF-Band or L-Band configuration. The ordering information is available hereafter: XSSR-VYP0-2502: DVB-S/DSNG/S2 Modulator IF & L-Band output 1U Rack XSSR-DE4I-1992: 4+1 IF-Band switching unit ASI & RF switching 3U rack XSSR-DE4L-1992: 4+1 L-Band switching unit ASI & RF switching 3U rack XSSR-DE8I-1992: 8+1 IF-Band switching unit ASI & RF switching 3U rack XSSR-DE8L-1992: 8+1 L-Band switching unit ASI & RF switching 3U rack 3.1 XSSR-DExx-1992 switching unit The switching unit is delivered in a 19" 3 RU chassis, which provides at the front side: device panel for quick configuration & monitoring, two hot-pluggable power supply modules. Confidentiel TeamCast Page 6/24

7 Figure 2: XSSR-DExx-1992 front panel The rear panel detailed below is the 8+1 configuration. Figure 3: rear panel of the redundancy switching unit Output redundancy unit: ASI interfaces Each ASI signal module supports 2 ASI interfaces. Confidentiel TeamCast Page 7/24

8 Figure 4: ASI signal module In normal operation, each input (" ") signal is routed to the corresponding output (" ") i.e. input "A" to output "A" and input "B" to output "B". The output redundancy unit is built up in the following fashion. Here an 8 channel redundancy unit with 75 Ohm, BNC (f) connectors is shown. Figure 5: Output redundancy unit Input redundancy unit: L-Band signals These units are used for L-Band signals for the following references: Confidentiel TeamCast Page 8/24

9 xssr-de8l-1992, xssr-de4l Figure 6: L-Band switching module In normal operation, each input (" ") signal is routed to the corresponding output (" "), i.e. input "A" to output "A" and input "B" to output "B". The input redundancy unit is built up in the following fashion. Here an 8 channel redundancy unit with 50 Ohm, SMA (f) connectors is shown. Figure 7: L-Band switching modules Confidentiel TeamCast Page 9/24

10 3.1.3 Input redundancy unit: IF-Band signals These units are used for IF-Band signals for the following references: xssr-de8i-1992, xssr-de4i Figure 8: IF-Band switching module In normal operation, each input (" ") signal is routed to the corresponding output (" "), i.e. input "A" to output "A" and input "B" to output "B". In case of alarm, the common board input is routed to the output signal CPU Module The CPU module is located on the rear side of the chassis and manages the surveillance and control functionality of the device. Figure 9: CPU module Confidentiel TeamCast Page 10/24

11 3.2 Vyper Satellite modulators The figure below shows the modulator front panel. Figure 10: Vyper Front Panel The LED status is described in the table below: Name Description Power Lock Output Alarm Green off: power off Green fix: power on Green off: no input detected Green flashing: an input is detected but not modulated Green fix: an input is modulated Green off: no RF output (failure or mute condition) Green fix: the RF output is available (normal mode) Green flashing: Output signal is generated in test mode Off: No critical error detected Red fix: Module failure Red flashing: Active Input failure or Clock reference loss Table 1: Vyper LED status The figure below shows the modulator rear panel. Figure 11: Vyper Rear Panel The connectors involved in the N+1 redundancy system are described hereafter. ASI Stream Input interface x 2 General Function: ASI Input Connector: BNC Impedance 75 Ω Confidentiel TeamCast Page 11/24

12 Type: Performances Data rate: Mode: Format: Table 2: ASI input Input ASI: 0.1 to 200 Mbps maxi. Burst or Packet mode ASI: 188/204 bytes L-Band Output x 1 General Function: RF output Standards: DVB-S / DVB-S2 / DVB-S2X Name: RF_OUT Connector: N Impedance 50 Ω Type: Output Performances RF Frequency: 950MHz to 2150MHz Bandwidth: 0.1 MHz to 72MHz Level: +7dBm / -35dBm Table 3: L-Band Output IF-Band Output x 1 General Function: IF output Standards: DVB-S / DVB-S2 / DVB-S2X Name: IF_OUT Connector: BNC Impedance 75 Ω Type: Output Performances RF Frequency: 50MHz to 180MHz Bandwidth: 0.1 MHz to 72MHz Level: +5dBm / -35dBm 3.3 Complete detailed system Table 4: IF-Band Output The figure below summarizes the complete autonomous N+1 system for the L- Band configuration including the local Ethernet network. Confidentiel TeamCast Page 12/24

13 Figure 12: N+1 redundancy wiring diagram Confidentiel TeamCast Page 13/24

14 4. Software Configuration 4.1 Vyper Satellite Modulators The units can be remotely control with a Web Browser or SNMP. The default IP configuration is: Ethernet port 1: o IP address: o Network mask: o Gateway address: Ethernet port 2: o IP address: o Network mask: o Gateway address: To log in on the web browser, use: login: admin password: root The following sections summarize the different steps to configure the N+1 modulators General panel This General panel is described below in Figure 13. On this panel, the user must: verify that the N+1 modulators embed the same firmware version, configure the new IP parameters on the N+1 modulators to build the local Ethernet network: different IP addresses belonging to the same sub network, setup the Trap configuration on the N main modulators: o activate the Trap, o configure the destination IP address with the switching unit IP address, o Change the Trap port if necessary, Until end of the document, the IP addresses will be: Backup modulator: Main modulator 1: Main modulator 2: Main modulator 3: Main modulator 4: XSSR-DExx-1992 Switching unit: Confidentiel TeamCast Page 14/24

15 4.1.2 Config panel Figure 13: General panel of Main modulator 1 This section only concerns the N main modulators. This panel allows the user to setup the specific configuration for the N main modulators concerning the inputs, modulation and outputs parameters. Please refer to [D1] for more details Profiles panel Once the configuration done on all main modulators, the user must: 1. store the configuration in a specific profile, Confidentiel TeamCast Page 15/24

16 2. export the N profiles on the PC hard drive. In case of failure, these profiles will be used to configure the backup modulator. On the backup modulator, the N different profiles should be imported from the PC hard drive. We should see on the backup modulator the following figure for N=4: Alarm panel Figure 14: Profiles panel of the backup modulator This section only concerns the N main modulators. This panel lists the different alarms that the product is able to monitor. The user must enable Trap notification on alarms he wants to monitor to initiate a switch. In the example below, the user selects all the General Alarms and only 2 product alarms: ASI input synchronization with critical severity RF output status with critical severity Confidentiel TeamCast Page 16/24

17 Figure 15: Alarms Panel of the main modulators 4.2 XSSR-DExx-1992 Switching Unit The unit can be remotely control with a Web Browser or SNMP. The default IP configuration of the Ethernet port is: IP address: Network mask: Gateway address: To log in on the web browser, use: login: ADMIN password: ADMIN Confidentiel TeamCast Page 17/24

18 The switching unit manages the N+1 standalone system with the SNMP protocol on the local Ethernet network. Thanks to its TRAC feature, the unit is able to send SNMP set on reception of TRAP. The following sections summarize the different steps to configure the N+1 modulators. The switch unit version used for this paper is detailed in the figure hereafter System setup Figure 16: XSSR-DExx-1992 Info Panel As previously done for the modulators, the IP parameters should be changed to fit the Ethernet network IP characteristics. Until end of the document, we will keep these default IP parameters for the switching unit. Figure 17: XSSR-DExx-1992 System Setup Confidentiel TeamCast Page 18/24

19 4.2.2 Switching actions The user must define the actions the switching unit must execute on reception of a defined TRAP notification. An action is basically a load of a profile on the backup modulator thanks to a SNMP set. One action is configured for each main modulator: SNMP set on OID with string parameter Profile_Main_1, SNMP set on OID with string parameter Profile_Main_2, SNMP set on OID with string parameter Profile_Main_3, SNMP set on OID with string parameter Profile_Main_4. The figure below shows the final configuration of 4 actions with: SNMP parameters of the backup modulators and the status LED, Definition of the SNMP OID set. Figure 18: XSSR-DExx-1992 Switching Actions TRAC Setup TRAC stands for "Trap Receiver Action Controller" and is a powerful feature enabling the device to execute Switching Actions (please refer to 4.2.2) based on received SNMP traps. The figure below shows the configuration of TRAP reception condition corresponding respectively to the 4 main modulators. In the example, all Trap received from the main modulator 1 ( ) with critical severity ( OID = 3) and alarm on ( OID = 1) will generate the action switch_main_1. When the Source IP LED is not green, it could be necessary to restart the switching unit. Confidentiel TeamCast Page 19/24

20 4.2.4 IP Monitor Figure 19: XSSR-DExx-1992 TRAC setup IP Monitor feature is able to detect specific failure (power failure, switch off, Ethernet link loss ) on the main modulators thanks to ICMP protocol. Like the previous feature, a switching action is linked to this failure event. When the Destination IP LED is not green, it could be necessary to restart the switching unit. The figure below shows the IP Monitor configuration Data Backup Figure 20: XSSR-DExx-1992 IP Monitor setup The configuration process previously described can be quickly setup by using the Data Backup feature. The backup file is available on request and can be easily imported in the Data Backup panel described below. Confidentiel TeamCast Page 20/24

21 5. Operation Figure 21: XSSR-DExx-1992 Data Backup 5.1 XSSR-DExx-1992 Modes of operation The switching unit can be configured in 3 different modes: Local Mode, Remote Mode, Auto Mode. Note: The operation mode can be changed with the mode push button of the device panel, via Web Interface, and via SNMP. The factory default for the operation mode is Remote Mode Local Mode In Local Mode the device executes commands, which are issued via push button actions at the device panel, or (also in parallel) via Web Interface. The communication to the SNMP remote interface is disabled for modifying the settings of the device and for switching commands, but open for surveillance and status queries Remote Mode The Remote Mode is implemented for the operation via SNMP. In Remote Mode the status of the product is still indicated via the LEDs on the device and via Web Interface, but the buttons on the device panel are locked and the control functionality of the Web Interface is disabled. Confidentiel TeamCast Page 21/24

22 5.1.3 Auto Mode The Auto Mode is used for the TRAC functionality of the Web Interface. It is the required mode to control automatically the N+1 modulators. As in Remote Mode, the status of the device is still indicated via the LEDs on the device and via Web Interface, but the buttons on the device panel are locked and the control functionality of the Web Interface is disabled. The communication to the SNMP remote interface is disabled for modifying the settings of the device and for switching commands, but open for status and surveillance queries. During Redundancy Operation, the system will be controlled in Auto Mode. During installation & maintenance operations, the system will be controlled in Local Mode. 5.2 Nominal State The nominal state is shown hereafter: the switch is waiting for a failure of a MAIN modulator: 5.3 Failure State Figure 22: XSSR-DExx-1992 Nominal State The failure state is shown hereafter: a failure was detected on the 2 nd main modulator. 5.4 Maintenance operation Figure 23: XSSR-DExx-1992 Failure State 1. Power OFF the MAIN modulator in failure, 2. Unplug the cables (Power supply, Ethernet, ASI, RF ), Confidentiel TeamCast Page 22/24

23 3. Replace the MAIN modulator in failure, 4. Plug the cables and power ON the modulator, 5. Configure the new main modulator (follow 4.1.1, 4.1.2, and 4.1.4), 6. Force XSSR-DExx-1992 switching unit to local mode with GUI or Front Panel, 7. Switch from backup modulator to main modulator with GUI or Front Panel, 8. Force XSSR-DExx-1992 switching unit to auto mode with GUI or Front Panel. Confidentiel TeamCast Page 23/24

24 6. Support contacts TEAMCAST CUSTOMER SUPPORT Tel (0) Fax (0) support@teamcast.com Confidentiel TeamCast Page 24/24

3.5 EXTERNAL NETWORK HDD. User s Manual

3.5 EXTERNAL NETWORK HDD. User s Manual 3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility

More information

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry. IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input

More information

Chapter 3 Management. Remote Management

Chapter 3 Management. Remote Management Chapter 3 Management This chapter describes how to use the management features of your ProSafe 802.11a/g Dual Band Wireless Access Point WAG102. To access these features, connect to the WAG102 as described

More information

Chapter 4 Management. Viewing the Activity Log

Chapter 4 Management. Viewing the Activity Log Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in

More information

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,

More information

Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version 01 30.09.11

Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version 01 30.09.11 Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version 01 30.09.11 Contents 1 Overview... 1 2 Background... 1 3 Key Features... 2 4 Typical Users... 2 5 Benefits to BGAN and

More information

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and

More information

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,

More information

SNMP Web Management. User s Manual For SNMP Web Card/Box

SNMP Web Management. User s Manual For SNMP Web Card/Box SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...

More information

Chapter 1 Installing the Gateway

Chapter 1 Installing the Gateway Chapter 1 Installing the Gateway This chapter describes how to set up the wireless voice gateway on your Local Area Network (LAN), connect to the Internet, and perform basic configuration. For information

More information

Technicolor ATSC-8. User s Guide. 2012 Technicolor. All Rights reserved

Technicolor ATSC-8. User s Guide. 2012 Technicolor. All Rights reserved Technicolor ATSC-8 User s Guide 2012 Technicolor. All Rights reserved Introduction This document describes the process and procedures for integrating the ATSC-8 product with the COM1000 digital head-end

More information

Internet Telephony PBX system IPX-1980

Internet Telephony PBX system IPX-1980 Internet Telephony PBX system IPX-1980 Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Hardware Installation... 4 2.1 Safety Instruction... 4 2.2 Front panel... 4 2.3 LED & Button

More information

ALOHA Load Balancer Quickstart guide

ALOHA Load Balancer Quickstart guide ALOHA Load Balancer Quickstart guide Summary 1 Package contents... 3 2 Preparing your Aloha... 4 3 Cabling... 5 3.1 Howto... 5 3.2 ALBBOX Overview... 6 3.3 ALB2K Overview... 7 3.4 ALB4K, ALB8K and ALB16K

More information

HWg-STE HWg-STE PoE MANUAL

HWg-STE HWg-STE PoE MANUAL HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.

More information

ASUS WL-5XX Series Wireless Router Internet Configuration. User s Guide

ASUS WL-5XX Series Wireless Router Internet Configuration. User s Guide ASUS WL-5XX Series Wireless Router Internet Configuration User s Guide Contents Chapter 1 Introduction:...1 Chapter 2 Connecting the wireless router...1 Chapter 3 Getting to know your Internet connection

More information

TELECOM HF VHF UHF over IP

TELECOM HF VHF UHF over IP Analog Radio to IP Gateway TELECOM HF VHF UHF over IP The RADITEK of Radio Over IP interfaces are designed to merge the power and flexibility of IP with analog radio equipment and networks. This offers

More information

Link Gate SIP. (Firmware version 1.20)

Link Gate SIP. (Firmware version 1.20) Link Gate SIP (Firmware version 1.20) User guide v1.0 1 Content 2 1. Technical parameters - Dimensions 133 x 233 x 60 mm - Weight 850 g - Operating position various - Operating condition temperature: +5

More information

Technical Note. Monitoring Ethernet Traffic with Tolomatic ACS & Managed Switch. Contents

Technical Note. Monitoring Ethernet Traffic with Tolomatic ACS & Managed Switch. Contents Monitoring Ethernet Traffic with Tolomatic ACS & Managed Switch Contents 1. Introduction...2 2. Equipment...2 3. Software...3 4. Definitions...3 5. Procedure...3 6. Change PC IP Address...3 7. Network

More information

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,

More information

User guide for NANOSTATION 2

User guide for NANOSTATION 2 User guide for NANOSTATION 2 1. Connecting hardware. Connecting your Nanostation 2 to your network is very easy, as it s using the POE (Power Over Ethernet) technology. For this you will need two direct

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

4G LTE router: MIFI-4G

4G LTE router: MIFI-4G 4G LTE router: MIFI-4G 1. Introduction MIFI-4G is a multi-function device: WIFI router & power bank. It support 3G/4G internet, WIFI repeater and Ethernet, support 10 users simultaneously. Any terminal

More information

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER INTRODUCTION The equipment described here below is a TRANSMITTER that allows to receive a signal coming from satellite, to demodulate it to have the ASI format, to present it into DVB-H standard by a DVB-H

More information

SNMP-1 Configuration Guide

SNMP-1 Configuration Guide SNMP-1 Configuration Guide You must configure the Net Logic Card before it can operate properly. You have two methods to configure the Net Logic Card: Using telnet or terminal. Using Telnet 1. Make sure

More information

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM Poseidon 3265 starting guide Poseidon 3265 Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM 1) Connecting Poseidon 3265 1.1) Check DIP switches settings. For installation

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1

Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1 Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...

More information

Network Power Manager. User Manual

Network Power Manager. User Manual Network Power Manager User Manual Table of Contents 1. Introduction... 1 2. PDU Package... 2 3. Function... 3 4. Installation... 4 5. Web Interface... 5 1. Introduction The PDU is an Internet ready device

More information

NMS300 Network Management System

NMS300 Network Management System NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate

More information

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES www.unipowerco.com 2014 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive, Coral Springs,

More information

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide BEC 6200WZL 4G/LTE Cellular Broadband Router Quick Start Guide 1 BEC 6200WZL 4G/LTE Cellular Broadband Router PLEASE READ THE QUICK START GUIDE AND FOLLOW THE STEPS CAREFULLY. THIS QUICK START GUIDE WILL

More information

Ethernet Radio Configuration Guide

Ethernet Radio Configuration Guide Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834

More information

SNMP Manager User s Manual

SNMP Manager User s Manual SNMP Manager User s Manual Table of Contents 1. Introduction...2 2. SNMP Manager Install, Quick Start and Uninstall...2 2.1. Software Installation...2 2.2. Software Quick Start...2 2.3. Software Uninstall...2

More information

User Guide. Guide d utilisation Guida dell'utente Benutzerhandbuch Guía del usuario Guia do Usuário WNA-100. Wireless Network Adapter

User Guide. Guide d utilisation Guida dell'utente Benutzerhandbuch Guía del usuario Guia do Usuário WNA-100. Wireless Network Adapter WNA-100 Wireless Network Adapter User Guide Guide d utilisation Guida dell'utente Benutzerhandbuch Guía del usuario Guia do Usuário www.xerox.com/office/wna Copyright 2007 Xerox Corporation. All Rights

More information

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW) Page 1 of 20 Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW) Document ID: 50036 Contents Introduction Prerequisites Requirements Components Used Network Diagram The Role of Switched

More information

If you are unable to set up your Linksys Router by using one of the above options, use the steps below to manually configure your router.

If you are unable to set up your Linksys Router by using one of the above options, use the steps below to manually configure your router. This article describes how to manually configure a Linksys Router for broadband DSL that uses PPPoE (Point-to-Point Protocol over Ethernet) for authentication. For automatic configuration options, please

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

Multi-Profile CMOS Infrared Network Camera

Multi-Profile CMOS Infrared Network Camera Multi-Profile CMOS Infrared Network Camera Quick Start Guide About multi-profile Multi-profile stands for simultaneously video stream. The Network Camera and Video Server can generate MPEG4 and MJPEG streaming

More information

User Manual. EtherUSB

User Manual. EtherUSB User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents

More information

PowerShield SNMP Adaptor

PowerShield SNMP Adaptor PowerShield SNMP Adaptor This manual describes the setup and operation of the PowerShield SNMP adaptor for the Sentinel battery monitoring system 6300-079A SNMP User Manual Page 1 of 9 1. Connecting the

More information

How to setup EW-7438RPn with a Windows computer to extend an existing Wi-Fi network

How to setup EW-7438RPn with a Windows computer to extend an existing Wi-Fi network 2 How to setup EW-7438RPn with a Windows computer to extend an existing Wi-Fi network Note: 1. This instruction use pictures from EW-7438RPn firmware v1.13. 2. If you need to restore to the default settings,

More information

Chapter 6 Using Network Monitoring Tools

Chapter 6 Using Network Monitoring Tools Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your Wireless-G Router Model WGR614v9. You can access these features by selecting the items under

More information

GPS NTP Time Server for Intranet Networks DIN RAIL Version

GPS NTP Time Server for Intranet Networks DIN RAIL Version GPS NTP Time Server for Intranet Networks DIN RAIL Version Description: GPS NTP time server is very simple low cost solution for Ethernet / Intranet time synchronization. Each computer or devices with

More information

How To Check If Your Router Is Working Properly

How To Check If Your Router Is Working Properly Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Dual Band Wireless-N Router WNDR3300. You can access these features by selecting the

More information

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide BiPAC 7800NL Wireless-N ADSL2+ Firewall Router Quick Start Guide BiPAC 7800NL Wireless-N ADSL2+ Firewall Router Billion BiPAC 7800NL Wireless-N ADSL2+ Firewall Router PLEASE READ THE QUICK START GUIDE

More information

This section will focus on basic operation of the interface including pan/tilt, video, audio, etc.

This section will focus on basic operation of the interface including pan/tilt, video, audio, etc. Catalogue Basic Operation... 2 For Internet Explorer... 2 For Other Non-IE Web Browsers... 5 Camera Settings... 6 System... 6 About... 6 PT Setting... 7 Backup and Restore Setup... 8 NTP Setting... 8 System

More information

Network Video Recorder Quick Operation Guide

Network Video Recorder Quick Operation Guide Network Video Recorder Quick Operation Guide UD.6L0202B1119A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module Panduit Corp. 2010 TDP43ME NetPS PA26306A01 Rev. 01 11-2010 Network Printer Server Control Center for Ethernet Module NOTE: In the interest of higher quality and value, Panduit products are continually

More information

AC750 WiF Range Extender

AC750 WiF Range Extender Model EX3700 User Manual May 2015 202-11487-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on

More information

Voice Over Internet Protocol (VoIP) Configuration

Voice Over Internet Protocol (VoIP) Configuration (VoIP) Configuration ENGINEERING REPORT No: 02-003 Introduction This report describes interfacing the IPCS VoIP Gateway Model EGW-902 to an ESTeem Model 192E Wireless Ethernet radio modem in a demonstration

More information

Quick Note 53. Ethernet to W-WAN failover with logical Ethernet interface.

Quick Note 53. Ethernet to W-WAN failover with logical Ethernet interface. Quick Note 53 Ethernet to W-WAN failover with logical Ethernet interface. Digi Support August 2015 1 Contents 1 Introduction... 2 1.1 Introduction... 2 1.2 Assumptions... 3 1.3 Corrections... 3 2 Version...

More information

Operation and Maintenance Terminal (OMT 1.2) User s Manual for use with MPW2100-23

Operation and Maintenance Terminal (OMT 1.2) User s Manual for use with MPW2100-23 Operation and Maintenance Terminal (OMT 1.2) User s Manual for use with MPW2100-23 1. Outline 1.1 Operation and Maintenance Terminal The OMT is powerful software when it is incorporated with the repeaters;

More information

User s Manual Network Management Card

User s Manual Network Management Card User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction

More information

Assign a static IP address (192.168.1.100) for your computer. Please refer to T3 in Troubleshooting guide on page 10 if you need assistance.

Assign a static IP address (192.168.1.100) for your computer. Please refer to T3 in Troubleshooting guide on page 10 if you need assistance. Assign a static IP address (192.168.1.100) for your computer. Please refer to T3 in Troubleshooting guide on page 10 if you need assistance. You may need to write down the original settings as a backup.

More information

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0 EV-1000 Series DVR Quick Operation Guide Version 1.0.0 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to

More information

N300 WiFi Range Extender WN2000RPT User Manual

N300 WiFi Range Extender WN2000RPT User Manual N300 WiFi Range Extender WN2000RPT User Manual December 2013 202-11333-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device,

More information

BROADBAND INTERNET ROUTER USER S MANUAL. Version 1.0. - Page 1 of 13 -

BROADBAND INTERNET ROUTER USER S MANUAL. Version 1.0. - Page 1 of 13 - Version 1.0 - Page 1 of 13 - 10/100M Broadband Router GETTING TO KNOW 2 3 4 1 5 7 6 - Page 2 of 13 - LED Indicator S/N Indicator Function 1 Power LED (Green) LED lights up steadily indicate that the power

More information

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6

More information

Watchdog Monitor user guide

Watchdog Monitor user guide General The Watchdog AW-4, in short AW-4, can be controlled and monitored by a centralized monitor server. This server is located in a large Dutch server centre with high speed connections, directly connected

More information

MAX-306M1 Series. WiMAX MIMO Outdoor Simple CPE DEFAULT LOGIN DETAILS. Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz)

MAX-306M1 Series. WiMAX MIMO Outdoor Simple CPE DEFAULT LOGIN DETAILS. Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz) MAX-306M1 Series Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz) WiMAX MIMO Outdoor Simple CPE Firmware v3.70 Edition 2, 12/2009 DEFAULT LOGIN DETAILS IP Address: Username: http://192.168.1.1 admin

More information

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400 PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400 PePWave Surf Outdoor Series: Surf AP 200/400-X, PolePoint 400-X, Surf 400-DX User Manual Document Rev. 1.2 July 07 COPYRIGHT & TRADEMARKS

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

FMUX04 SNMP Tutorial

FMUX04 SNMP Tutorial FMUX04 SNMP Tutorial Abstract: This tutorial will guide the new comer on how to configure the FMUX04 with SNMP option for management and how to access the enterprise MIB for monitoring Optical signal/ber

More information

Installation & Operations Manual

Installation & Operations Manual Installation & Operations Manual VoIP Command Center Made in the USA 3 Year Warranty N56 W24720 N. Corporate Circle Sussex, WI 53089 800-451-1460 262-246-4828 (fax) www.rathmicrotech.com www.area-of-refuge.com

More information

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version 1.05.00

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version 1.05.00 CX Series Video Recording Server CX784 / CX788 / CX7816 Quick Start Guide Version 1.05.00 Contents 1.Introduction...1 1.1.Packages Contents...1 1.2.Hardware Features...2 1.3.Functional Features...4 1.4.Hard

More information

Nokia Siemens Networks. CPEi-lte 7212. User Manual

Nokia Siemens Networks. CPEi-lte 7212. User Manual Nokia Siemens Networks CPEi-lte 7212 User Manual Contents Chapter 1: CPEi-lte 7212 User Guide Overview... 1-1 Powerful Features in a Single Unit... 1-2 Front of the CPEi-lte 7212... 1-2 Back of the CPEi-lte

More information

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD

More information

Turn on all of your network devices and then check to see if the LEDs on the Access Point display normally as the diagram below describes.

Turn on all of your network devices and then check to see if the LEDs on the Access Point display normally as the diagram below describes. Connect to the Access Point with the Ethernet cable or via wireless. The default SSID of the Access Point is TP-LINK_ XXXXXX. The XXXXXX is the last 6 characters of the Access Point s MAC address. Plug

More information

OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R

OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R OSBRiDGE 5XLi Configuration Manual Firmware 3.10R 1. Initial setup and configuration. OSBRiDGE 5XLi devices are configurable via WWW interface. Each device uses following default settings: IP Address:

More information

AudioCodes Mediant 1000 Configuration Guide

AudioCodes Mediant 1000 Configuration Guide AudioCodes Mediant 1000 Configuration Guide 2010 FaxBack, Inc. All Rights Reserved. NET SatisFAXtion and other FaxBack products, brands and trademarks are property of FaxBack, Inc. Other products, brands

More information

Chapter 6 Using Network Monitoring Tools

Chapter 6 Using Network Monitoring Tools Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Wireless-N Gigabit Router WNR3500. You can access these features by selecting the items

More information

RMS-2FS Stereo FM Transmitter Monitoring System

RMS-2FS Stereo FM Transmitter Monitoring System RMS-2FS Stereo FM Transmitter Monitoring System The RMS-2FS FM Monitor station is a complete system solution, designed to remotely monitor the input and output signals of the Stereo FM transmitters and

More information

www.css-timemachines.com Precision Clocks When you absolutely can't afford a time shift Installation and Operation Manual

www.css-timemachines.com Precision Clocks When you absolutely can't afford a time shift Installation and Operation Manual www.css-timemachines.com Precision Clocks When you absolutely can't afford a time shift Installation and Operation Manual Table of Contents 1. Introduction...1 2. Initial Setup...2 2.1 PoE...2 2.2 Network...2

More information

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3 SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,

More information

Gigabit Content Security Router CS-5800

Gigabit Content Security Router CS-5800 Gigabit Content Security Router CS-5800 Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Hardware Installation... 4 2.1 Safety Instruction... 4 2.2 Front panel... 4 2.3 LED & Button

More information

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield: the following parts are needed to test the unit: Arduino UNO R3 Arduino Wifi shield And reciever 5V adapter Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the

More information

Gigabyte Content Management System Console User s Guide. Version: 0.1

Gigabyte Content Management System Console User s Guide. Version: 0.1 Gigabyte Content Management System Console User s Guide Version: 0.1 Table of Contents Using Your Gigabyte Content Management System Console... 2 Gigabyte Content Management System Key Features and Functions...

More information

Chapter 10 Troubleshooting

Chapter 10 Troubleshooting Chapter 10 Troubleshooting This chapter provides troubleshooting tips and information for your ProSafe Dual WAN Gigabit Firewall with SSL & IPsec VPN. After each problem description, instructions are provided

More information

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian. Problem: Patton / 240T WAN Setup Platform: NetGuardian 240T This TKP is a guide to setting up a PPP to T1 WAN connection between a Patton Model 2603 Router and a NetGuardian 240T. The example in this guide

More information

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP RouteFinder SOHO SOHO Security Appliance EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP Quick Start Guide RouteFinder RF825 Series Quick Start Guide RouteFinder SOHO Security Appliance

More information

AC750 WiFi Range Extender

AC750 WiFi Range Extender Model EX6100 User Manual April 2014 202-11307-03 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number

More information

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo A typical set up for a router PCs can be connected to the router via USB or Ethernet. If you wish to use a telephone with the

More information

GPS NTP TIME SERVER Rack Version V2

GPS NTP TIME SERVER Rack Version V2 GPS NTP TIME SERVER Rack Version V2 Description: Server is dedicated to synchronize network devices local time/date to Universal Time (UTC) Devices synchronizing own local time through the NTP V3 protocol.

More information

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification: PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,

More information

PIM31 Remote Setup and Operational Procedures

PIM31 Remote Setup and Operational Procedures PIM31 Remote Setup and Operational Procedures 1 Remote Application and TCP/IP Setup PIM31 Remote Control Panel is the software to control the PIM31 unit from any PC using a TCP/IP cable connection. This

More information

VTO6xxx. IP door stations. User manual

VTO6xxx. IP door stations. User manual VTO6xxx IP door stations User manual Table of Contents 1 Product Appearance 2 Basic Function Introduction 2.1 Call Manager Center 2.2 Call User 2.2.1 Connecting Status 2.2.2 Calling Status 2.3 Monitor

More information

NETVIGATOR Wireless Modem Setup Guide. (TG789Pvn)

NETVIGATOR Wireless Modem Setup Guide. (TG789Pvn) NETVIGATOR Wireless Modem Setup Guide (TG789Pvn) Configure the NETVIGATOR Wireless Modem Make sure that system meets the following requirement prior to NETVIGATOR Wireless Modem usage: - Subscribers who

More information

Using Zistos PNSC over BGAN

Using Zistos PNSC over BGAN Using Zistos PNSC over BGAN Self powered Field Surveillance and Monitoring Version 01 12 th November 2009 1 Contents 1 Overview 1 2 Applications 1 3 Features & Benefits 1 4 Network Diagram 2 5 Connecting

More information

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It

More information

2100 Series VoIP Phone

2100 Series VoIP Phone 2100 Series VoIP Phone Installation and Operations Manual Made in the USA 3 Year Warranty N56 W24720 N. Corporate Circle Sussex, WI 53089 RP8500SIP 800-451-1460 262-246-4828 (fax) Ver. 4 www.rathmicrotech.com

More information

ADSL MODEM. User Manual V1.0

ADSL MODEM. User Manual V1.0 ADSL MODEM User Manual V1.0 CONTENTS 1.OVERVIEW... 3 1.1 ABOUT ADSL... 3 1.2 ABOUT ADSL2/2+... 3 1.3 FEATURES... 3 2 SPECIFICATION... 4 2.1 INTERFACE INTRODUCTION... 4 2.1.1 INDICATOR AND INTERFACE...

More information

Setup Guide. An installation space and network environment must be prepared in advance.

Setup Guide. An installation space and network environment must be prepared in advance. FUJITSU Storage ETERNUS DX200F All Flash Array Setup Guide STEP Preparation An installation space and network environment must be prepared in advance. Prepare the following manuals: Manuals for the ETERNUS

More information

ALL0237R. Wireless N 300Mbit Access Point/Repeater. User s Manual

ALL0237R. Wireless N 300Mbit Access Point/Repeater. User s Manual ALL0237R Wireless N 300Mbit Access Point/Repeater User s Manual ALLNET ALL0237R User Manual Table of Contents About the Device... 3 Minimum System Requirements... 5 Package Contents... 5 Device Overview...

More information

Emerson Smart Firewall

Emerson Smart Firewall DeltaV TM Distributed Control System Product Data Sheet Emerson Smart Firewall The Emerson Smart Firewall protects the DeltaV system with an easy to use perimeter defense solution. Purpose built for easy

More information

T3 Mux M13 Multiplexer

T3 Mux M13 Multiplexer T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract

More information

P-791R v2. Quick Start Guide. G.SHDSL.bis Router DEFAULT LOGIN. Administrator Password 1234. User Password. Version 1.00 4/2007 Edition 1

P-791R v2. Quick Start Guide. G.SHDSL.bis Router DEFAULT LOGIN. Administrator Password 1234. User Password. Version 1.00 4/2007 Edition 1 P-791R v2 G.SHDSL.bis Router Quick Start Guide Version 1.00 4/2007 Edition 1 DEFAULT LOGIN IP Address http://192.168.1.1 Administrator Password 1234 User Password user Copyright 2007. All rights reserved.

More information

Barracuda Link Balancer

Barracuda Link Balancer Barracuda Networks Technical Documentation Barracuda Link Balancer Administrator s Guide Version 2.2 RECLAIM YOUR NETWORK Copyright Notice Copyright 2004-2011, Barracuda Networks www.barracuda.com v2.2-110503-01-0503

More information

Quick Start Guide. DVR DS-7200HWI-SH Series DVR. www.hikvision.com. First Choice For Security Professionals

Quick Start Guide. DVR DS-7200HWI-SH Series DVR. www.hikvision.com. First Choice For Security Professionals Quick Start Guide DVR DS-7300HWI-SH Series DVR DS-7200HWI-SH Series DVR NOTE: For more detailed information, refer to the User s Manual on the CD-ROM. You must use your PC or MAC to access the files. www.hikvision.com

More information

Adding or replacing a mesh node in an existing mesh network

Adding or replacing a mesh node in an existing mesh network Adding or replacing a mesh node in an existing mesh network Use this procedure to add or replace a in an existing mesh For this procedure to work all nodes running the same firmware version. Before you

More information

Installation Guide for LynxClient

Installation Guide for LynxClient Installation Guide for LynxClient Technical Support: 972-231-6874 Ext. 140 8am to 5pm CST Email: lynx@mitsi.com PC Keyboard Duress Button LynxKey & LynxKeyPro USB Duress Button LynxUSB Notification Popup

More information