Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER
|
|
|
- Alyson Dean
- 9 years ago
- Views:
Transcription
1 Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER
2 Contents Design principles and operating sequence Page 1.1 Principle components Mode of operation (at rest) Mode of operation (heating) Mode of operation (DHW) Safety devices 2 Technical data Page 2.1 Central heating Domestic hot water Gas pressure Expansion vessel Dimensions Clearances Connections Electrical Flue details Efficiency Pump duty Appliance 4 General requirements (UK) Page 3.1 Related documents Location of appliance Gas supply Flue system Air supply Water circulation Pipework Automatic by-pass Drain cocks Air release points Expansion vessel Filling point Low pressure sealed system Frequent filling Electrical supply Showers Mounting on a combustible surface Timber framed building Inhibitors 7 Installation Page 4.1 Delivery Contents Unpacking Preparation for mounting the appliance Fitting the flue Concentric horizontal flue Concentric vertical flue Connecting the gas and water Gas Flow and return Cold water inlet Hot water outlet Safety valve Condense pipe Electrical connections Casing removal Appliance terminal block Connecting the mains (230V) input 11 Commissioning Page 5.1 Gas supply installation The heating system Initial filling of the system Initial flushing Filling the hot water system Pre-operation checks Initial lighting Checking burner pressures Final flushing of the heating system Inhibitors Setting the boiler operating temperature Setting the DHW temperature Setting the system design pressure Regulating the hot water Changing the flow restrictor Regulating the central heating system Final checks Instructing the user 13 Servicing instructions Page 6.1 General Routine annual servicing Replacement of components Component removal procedure Pump assembly Safety valve Automatic air release valve Water pressure switch Pressure gauge Primary thermistor High limit thermostat PCB Gas valve Integral time switch Electrode, burner thermostat, burner & injectors Flue fan Main heat exchanger Air pressure switch Flow restrictor DHW flow switch DHW heat exchanger Valve actuator Divertor valve cartridge DHW thermistor Automatic by-pass DHW non-return valve Expansion vessel Expansion vessel removal (with sufficient clearance above) Expansion vessel removal (with insufficient clearance above) Latent heat collector Dismantling the latent heat collector Condense trap removal 19 Checks, adjustments and fault finding page 7.1 Checking appliance operation Appliance mode of operation Selector switch in the OFF position Selector switch in the hot water only position Selector switch in the heating & hot water position Appliance functions DHW mode Heating mode Checking & adjusting burner pressure Setting the maximum burner pressure Setting the minimum burner pressure Setting the minimum CH output Combustion analysis test Checking the expansion vessel External faults Installation faults Electrical checks Earth continuity test Short circuit check Polarity check Reversed polarity or supply fault Resistance to earth check Fault finding Replacing the main PCB Fault codes Fault finding Wiring diagrams Page 8.1 External wiring Typical control applications Room thermostat Other controls 31 Functional diagram 32 Exploded diagrams Page Table L.P.G. instructions Page 10.1 Related documents Technical data Converting the appliance gas supply Gas supply Gas supply installation Checking & adjusting burner pressure Setting the maximum burner pressure Setting the minimum burner pressure 40 41
3 INTRODUCTION The Sabre HE range of appliances is comprised of 2 models of high-efficiency combination boiler with inputs to heating & DHW of 25, 29 & 35kW respectively. Each appliance - by design - incorporates electronic ignition, circulating pump, expansion vessel, safety valve, pressure gauge and automatic by-pass. The Sabre HE range is produced as room sealed, category II2H3P appliances, suitable for internal wall mounting applications only. They are provided with a fan powered flue outlet with an annular coaxial combustion air intake that can be rotated - horizontally - through 360 degrees for various horizontal or vertical applications. The Sabre HE range is approved for use with C12 & C32 type flue applications. These appliances are designed for use with a sealed system only; consequently they are not intended for use on open vented systems Fig.1 General Layout Fig. 1 1 Diverter valve motor 2 Discharge valve 3 Domestic hot water heat exchanger 4 Safety valve 5 Pump 6 Pressure switch 7 Auto air vent (AAV) 8 Electrode 9 Main burner 10 Main heat exchanger 11 Latent heat collector 12 Flue gas analysis test point 13 Flue outlet 14 Air intake 15 Differential pressure switch 16 Silicone pressure tube (-) 17 Silicone pressure tube (+) 18 Fan assembly 19 CH NTC sensor 20 Combustion chamber 21 High limit thermostat 22 Expansion vessel 23 Condensate pressure switch 24 Ignition transformer 25 Condense trap 26 Modulator coil 27 Gas valve 28 DHW flow switch 29 Pressure gauge 30 DHW position 31 Mode selector switch 32 Fault indicator led 33 CH position 34 Timeclock
4 SECTION 1 DESIGN PRINCIPLES AND OPERATING SEQUENCE 1.1 PRINCIPLE COMPONENTS A fully integrated electronic control board featuring electronic temperature control, anti-cycle control, pump over-run, LED fault indicator, full gas modulation. Low-water-content, copper heat exchanger. Electronic ignition with flame supervision. Integral high-head pump. Fan. Air pressure switch. Expansion vessel. Water pressure switch. Two-stage gas valve. Pressure gauge. Safety valve. Condense switch. 1.2 MODE OF OPERATION (at rest) When the appliance is at rest and there are no requests for heating or DHW, the following functions are active: Frost-protection system: the frost-protection system protects the appliance against the risk of frost damage. Should the temperature of the appliance fall to 5 C, the boiler will function in the heating mode at minimum power until it reaches 35 C. Anti-block function: the anti-block function enables the pump and divertor valve actuator, to be energised for short periods, when the appliance has been inactive for more than 19-hours. expansion vessel AAV Fig. 2 pump diverter valve motor automatic by-pass safety valve latent heat collector CH return CH flow flue outlet air intake gas valve DHW heat exchanger DHW outlet pressure switch main heat exchanger CH NTC sensor main burner DHW temperature sensor Domestic cold water inlet water pressure switch DHW non return valve DHW flow switch 1.3 MODE OF OPERATION (Heating) When there is a request for heat via the time clock and/or any external control, the pump and fan are started, the fan will then prove the air pressure switch. At this point an ignition sequence is enabled. Ignition is sensed by the electronic circuitry to ensure flame stability at the burner. Once successful ignition has been achieved, the electronic circuitry increases the gas rate to 75% for a period of 15 minutes. Thereafter, the boiler s output will either be increase to maximum or modulate to suit the set requirement. When the appliance reaches the desired temperature the burner will shut down and the boiler will perform a three-minute anti-cycle (timer delay). When the request for heat has been satisfied the appliance pump and fan may continue to operate to dissipate any residual heat within the appliance. 1.4 MODE OF OPERATION (DHW) When there is a request for DHW via a hot water outlet or tap, the pump and fan are started, the fan will then prove the air pressure switch. At this point an ignition sequence is enabled. Ignition is sensed by the electronic circuitry to ensure flame stability at the burner. Once successful ignition has been achieved, the electronic circuitry increases the gas rate to maximum or will modulate output to stabilise the temperature. In the event of the appliance exceeding the desired temperature the burner will shut down until the temperature drops. When the request for DHW has been satisfied the appliance pump and fan may continue to operate to dissipate any residual heat within the appliance. 1.5 SAFETY DEVICES When the appliance is in use, safe operation is ensured by: A water pressure switch that monitors system water pressure and will deactivate the pump, fan and burner should the system water pressure drop below the rated tolerance. A high limit thermostat that over-rides the temperature control circuit to prevent or interrupt the operation of the burner. An air pressure switch that requires the fan to prove operation before the gas valve is energised. A pressure switch that interrupts the operation of the appliance if the condense pipe becomes blocked. A safety valve which releases excess pressure from the primary circuit. 2
5 SECTION 2 TECHNICAL DATA Central heating Heat input (kw) Maximum heat output@ 80/60 C (kw) Minimum heat output@ 80/60 C (kw) Maximum heat output@ 50/30 C (kw) Minimum heat output@ 50/30 C (kw) Minimum working pressure 0.5 bar 0.5 bar 0.5 bar Maximum working pressure 3.0 bar 3.0 bar 3.0 bar Minimum flow rate 350 l/h 350 l/h 350 l/h 2.2 Domestic hot water Maximum output (kw) Minimum output (kw) Flow rate (35 C rise) 10.2 l/min 11.9 l/min 14.3 l/min Maximum inlet pressure 6.0 bar 6.0 bar 6.0 bar Minimum inlet working pressure 0.15 bar 0.15 bar 0.15 bar Minimum flow rate 2 l/min. 2 l/min. 2 l/min. 2.3 Gas pressures Inlet pressure G mbar 20.0 mbar 20.0 mbar Maximum burner pressure 9.40 mbar 9.20 mbar mbar Minimum burner pressure (central heating) 3.50 mbar 2.70 mbar 2.10 mbar Minimum burner pressure (domestic hot water) 1.50 mbar 1.20 mbar 1.00 mbar Gross rate (central haeting, max - min) m 3 /h m 3 /h m 3 /h Injectors size 12 x 1.35 mm 14 x 1.35 mm 16 x 1.35 mm 2.4 Expansion vessel Capacity 8 litres 10 litres 10 litres Maximum system volume 76 litres 76 litres 76 litres Pre-charge pressure 1.0 bar 1.0 bar 1.0 bar 2.5 Dimensions Height 780 mm 780 mm 780 mm Width 400 mm 450 mm 500 mm Depth 332 mm 332 mm 332 mm Dry weight 40 kg 44 kg 46 kg 2.6 Clearances Sides 12 mm 12 mm 12 mm Top Ref. Condition 15 C, 1013,25 mbar, dry gas TE: L.P.G. data refer to section mm from casing or 25 mm above flue elbow, whichever is applicable Bottom 150 mm 150 mm 150 mm Front 600 mm 600 mm 600 mm 2.7 Connections Flow & return 22 mm 22 mm 22 mm Hot & cold water connections 15 mm 15 mm 15 mm Gas 15 mm 15 mm 15 mm Safety valve 15 mm 15 mm 15 mm Condense 21 mm 21 mm 21 mm 2.8 Electrical Voltage 230V/~ 50hz 230V/~ 50hz 230V/~ 50hz Power consumption 153 W 153 W 153 W Internal fuse 2 A 2 A 2 A External fuse 3 A 3 A 3 A 2.9 Flue details (concentric) Maximum horizontal flue length (60/100mm) 4.5 m 4.0 m 1.85 m Maximum vertical flue length (60/100mm) 5.5 m 5.0 m 2.85 m 2.10 Efficiency SEDBUK 86.9 Band B 86.7 Band B 86.4 Band B 3
6 2.11 PUMP DUTY Fig. 3 shows the flow rate available - after allowing for pressure loss through the appliance - for system requirements. When using this graph, apply only the pressure loss of the system. The graph is based on a 20 ºC temperature differential Residual head (x 100 mbar) 5,0 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 first speed second speed third speed Litres Per Hour (x100) Fig. 3 Residual head (x 100 mbar) 6,0 5,5 5,0 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 first speed second speed third speed Litres Per Hour (x100) Appliance x 94 ppm mg/kwh 92 ppm mg/kwh 89 ppm mg/kwh CO (max-min) 80 ppm - 80 ppm 100 ppm - 60 ppm 100 ppm ppm CO 2 (max-min) % % % CO/CO 2 ratio (max) to to to 1 CO/CO 2 ratio (min) to to to 1 SECTION 3 GENERAL REQUIREMENTS (UK) Fig. 4 Key Location Minimum distance A Below an opening (window, air-brick, etc.) 300 mm B Above an opening (window, air-brick, etc.) 300 mm C To the side of an opening (window, air-brick, etc.) 300 mm D Below gutter, drain-pipe, etc. 75 mm E Below eaves 200 mm F Below balcony, car-port roof, etc mm G To the side of a soil/drain-pipe, etc. 150 mm H From internal/external corner or boundary 300 mm I Above ground, roof, or balcony level 300 mm J From a surface or boundary facing the terminal 1200 mm K From a terminal facing a terminal 1200 mm L From an opening in the car-port into the building 1200 mm M Vertically from a terminal on the same wall 1500 mm N Horizontally from a terminal on the same wall 300 mm P From a structure to the side of the vertical terminal 500 mm Q From the top of the vertical terminal to the roof flashing As determined by the fixed collar of the vertical terminal 4
7 This appliance must be installed by a competent person in accordance with the Gas Safety (Installation & Use) Regulations. 3.1 RELATED DOCUMENTS The installation of this boiler must be in accordance with the relevant requirements of the Gas Safety (Installation & Use) Regulations, the local building regulations, the current I.E.E. wiring regulations, the bylaws of the local water undertaking, the Building Standards (Scotland) Regulation and Building Standards (Northern Ireland) Regulations. It should be in accordance also with any relevant requirements of the local authority and the relevant recommendations of the following British Standard Codes of Practice. 3.2 LOCATION OF APPLIANCE The appliance may be installed in any room or internal space, although particular attention is drawn to the requirements of the current I.E.E. wiring regulations and in Scotland, the electrical provisions of the Building Regulations, with respect to the installation of the appliance in a room or internal space containing a bath or shower. 3.3 GAS SUPPLY The gas meter - as supplied by the gas supplier - must be checked to ensure that it is of adequate size to deal with the maximum rated input of all the appliances that it serves. Installation pipes must be fitted in accordance with BS Pipe work from the meter to the appliance must be of adequate size. Pipes of a smaller size than the appliance gas inlet connection must not be used. The installation must be tested for soundness in accordance with BS6891. If the gas supply serves more than one appliance, it must be ensured that an adequate supply is maintained to each appliance when they are in use at the same time. 3.4 FLUE SYSTEM The terminal should be located where the dispersal of combustion products is not impeded and with due regard for the damage and discoloration that may occur to building products located nearby. The terminal must not be located in a place where it is likely to cause a nuisance (see fig. 4). Water vapour will condense on leaving the terminal and the effect of such pluming must be considered. BS 5440 PART 1 FLUES BS 5440 PART 2 FLUES & VENTILATION BS 5449 PART 1 FORCED CIRCULATION HOT WATER SYSTEMS BS 5546 INSTALLATION OF GAS HOT WATER SUPPLIES FOR DOMESTIC PURPOSES (2 ND FAMILY GASES) BS 6798 INSTALLATION OF BOILERS OF RATED INPUT T EXCEEDING 60kW BS 6891 LOW PRESSURE INSTALLATION PIPES BS 7074 PART 1 APPLICATION, SELECTION AND INSTALLATION OF EXPANSION VESSELS AND ANCILLARY EQUIPMENT FOR SEALED WATER SYSTEMS When an appliance is installed in a room or internal space containing a bath or shower, the appliance or any control pertaining to it must not be within reach of a person using the bath or shower. The location chosen for the appliance must permit the provision of a safe and satisfactory flue and termination. The location must also permit an adequate air supply for combustion purposes and an adequate space for servicing and air circulation around the appliance. Where the installation of the appliance will be in an unusual location special procedures may be necessary, BS 6798 gives detailed guidance on this aspect. A compartment used to enclose the appliance must be designed and constructed specifically for this purpose. An existing compartment/cupboard may be utilised provided that it is modified to suit. Details of essential features of compartment/ cupboard design including airing cupboard installations are given in BS This appliance is not suitable for external installation. If installed less than 2m above a pavement or platform to which people have access (including balconies or flat roofs) the terminal must be protected by a guard of durable material. The guard must be fitted centrally over the terminal. Refer to BS 5440 Part 1, when a terminal is sited less than 1m below a plastic gutter, or less than 500mm below a painted surface, a suitable one metre long heat shield should be fitted. 3.5 AIR SUPPLY The following notes are intended for general guidance only. This appliance is a room-sealed, fan-flued boiler, consequently it does not require a permanent air vent for combustion air supply. When installed in a cupboard or compartment, ventilation for cooling purposes is also not required. 3.6 WATER CIRCULATION Detailed recommendations are given in BS 5449 Part 1 and BS The following notes are for general guidance only. 5
8 3.6.1 PIPEWORK It is recommended that copper tubing to BS 2871 Part 1 is used in conjunction with soldered capillary joints. Where possible pipes should have a gradient to ensure air is carried naturally to air release points and that water flows naturally to drain cocks. Except where providing useful heat, pipes should be insulated to avoid heat loss and in particular to avoid the possibility of freezing. Particular attention should be paid to pipes passing through ventilated areas such as under floors, loft space and void areas AUTOMATIC BY-PASS The appliance has a built-in automatic by-pass. However it may be necessary to fit an external bypass should the design of the heating system require such. In any case, the design of the system should be such that it prevents boiler cycling DRAIN COCKS These must be located in accessible positions to facilitate draining of the appliance and all water pipes connected to the appliance. The drain cocks must be manufactured in accordance with BS AIR RELEASE POINTS These must be positioned at the highest points in the system where air is likely to be trapped. They should be used to expel trapped air and allow complete filling of the system EXPANSION VESSEL The appliance has an integral expansion vessel to accommodate the increased volume of water when the system is heated. It can accept up to 8 litres (25kW) or 10 litres (29 & 35kW) of expansion from within the system, generally this is sufficient, however if the system has an unusually high water content, it may be necessary to provide additional expansion capacity (see 6.19) FILLING POINT An approved method for initial filling of the system and replacing water lost during servicing etc. is required (see fig. 5). This method of filling must comply with the current Water Supply (Water Fittings) Regulations 1999 and Water Bylaws 2000 (Scotland). Fig. 5 flow/return pipe control valve temporary connection double check valve control valve supply pipe LOW PRESSURE SEALED SYSTEM An alternative method of filling the system would be from an independent make-up vessel or tank mounted in a position at least 1 metre above the highest point in the system and at least 5 metres above the boiler (see fig. 5a). The cold feed from the make-up vessel or tank must be fitted with an approved non-return valve and stopcock for isolation purposes. The feed pipe should be connected to the return pipe as close to the boiler as possible. Automatic air-vent Fig. 5a Non-return valve Heating return Make-up vessel or tank Stopcock FREQUENT FILLING Frequent filling or venting of the system may be indicative of a leak. Care should be taken during the installation of the appliance to ensure all aspects of the system are capable of withstanding pressures up to at least 3 bar. 3.7 ELECTRICAL SUPPLY The appliance is supplied for operation on 50Hz electrical supply; it must be protected with a 3-amp fuse. The method of connection to the mains electricity supply must allow for complete isolation from the supply. The preferred method is by using a double-pole switch with a contact separation of at least 3mm. The switch must only supply the appliance and its corresponding controls, i.e. time clock, room thermostat, etc. Alternatively an un-switched shuttered socket with a fused 3-pin plug both complying with BS 1363 is acceptable. 3.8 SHOWERS If the appliance is intended for use with a shower, the shower must be thermostatically controlled and be suitable for use with a combination boiler. 5.0 metres minimum 6
9 3.9 MOUNTING ON A COMBUSTIBLE SURFACE If the appliance is to be fitted on a wall of combustible material, a sheet of fireproof material must protect the wall TIMBER FRAMED BUILDING If the appliance is to be fitted in a timber framed building, it should be fitted in accordance with the Institute of Gas Engineers publication (IGE/UP/ 7) Guide for Gas Installations in Timber Frame Buildings INHIBITORS It is recommend that an inhibitor - suitable for use with copper and aluminium heat exchangers - is used to protect the boiler and system from the effects of corrosion and/or electrolytic action. The inhibitor must be administered in strict accordance with the manufacturers instructions*. *Water treatment of the complete heating system - including the boiler - should be carried out in accordance with BS 7593 and the Domestic Water Treatment Association s (DWTA) code of practice. Fig. 6a 35kW 30kW 25kW Fig. 6 7
10 SECTION 4 INSTALLATION 4.1 DELIVERY Due to the weight of the appliance it may be necessary for two people to lift and attach the appliance to its mounting. The appliance is contained within a heavyduty cardboard carton. Lay the carton on the floor with the writing the correct way up. 4.2 CONTENTS Contained within the carton is: the boiler the wall bracket appliance template an accessories pack containing appliance service connections and washers the instruction pack containing the installation & servicing instructions, user instructions, Benchmark logbook, guarantee registration card and a 3-amp fuse. 4.3 UNPACKING At the top of the carton pull both sides open - do not use a knife - unfold the rest of the carton from around the appliance, carefully remove all protective packaging from the appliance and lay the accessories etc. to one side. Protective gloves should be used to lift the appliance, the appliance back-frame should be used for lifting points. 4.4 PREPARATION FOR MOUNTING THE APPLI- ANCE The appliance should be mounted on a smooth, vertical, non-combustible surface, which must be capable of supporting the full weight of the appliance. Care should be exercised when determining the position of the appliance with respect to hidden obstructions such as pipes, cables, etc. When the position of the appliance has been decided - using the template supplied - carefully mark the position of the wall- mounting bracket (see fig. 6) and flue-hole (if applicable). 4.5 FITTING THE FLUE The top flue outlet permits both horizontal and vertical flue applications to be considered CONCENTRIC HORIZONTAL FLUE (For concentric vertical flue, see section 4.5.2). The appliance flue outlet elbow can be rotated through 360º on its vertical axis. In addition the flue may be extended from the outlet elbow in the horizontal plane (see 2.9). A reduction must also be made to the maximum length (see table below) when additional bends are used. Reduction for additional bends Bend 45º bend 0.5 metre 90º bend 1.0 metre Reduction in maximum flue length for each bend Horizontal flue terminals and accessories Part No. Description Min-Max Length 491 Horizontal flue kit for use with 1000 mm add. bends & extensions m extension 500 mm m extension 1000 mm m extension 2000 mm º bend (pair) N/A º bend N/A 499 Wall bracket N/A Fig. 7 Using the template provided, mark and drill a 115mm hole for the passage of the flue pipe. The hole should be drilled level to ensure any condense fluid that forms will drain back to the boiler. The fixing holes for the wall-mounting bracket should now be drilled and plugged, an appropriate type and quantity of fixing should be used to ensure that the bracket is mounted securely. Once the bracket has been secured to the wall, mount the appliance onto the bracket. Boiler Terminal or extension outer clamp FITTING THE HORIZONTAL FLUE KIT Carefully measure the distance from the centre of the appliance flue outlet to the edge of the finished outside wall (dimension X). Add 65mm to dimension X to give you dimension Y (see fig 7A). Measure dimension Y from the terminal end of the concentric flue pipe and cut off the excess from the 100mm pipe ensuring any burrs are removed. Using the cut-off piece of 100mm pipe as a guide, mark and cut the same length of pipe from the inner 60mm pipe (the 60mm should always project past the 100mm pipe by 30mm). Pass the concentric flue pipe through the previously drilled hole. Fit the flue bend to the boiler flue outlet and insert the concentric flue pipe into the flue bend ensuring the correct seal is made. Using the clamps, gaskets, and screws supplied, secure the flue bend to the appliance flue spigot and the flue terminal. TE Fit the internal (White) trim to the flue assembly prior to connecting the flue pipe to the bend. 8
11 125 mm CONCENTRIC VERTICAL FLUE The vertical flue terminal can be connected directly to the appliance flue outlet. Alternatively, an extension or bend can be connected to the appliance flue outlet if desired (see 4.4.2), however if additional bends are fitted, a reduction must be made to the maximum flue length (see table below). Fig. 7a X + 45 mm = Y Reduction for bends Bend Reduction in maximum flue length for each bend 45º bend 0.5 metre 90º bend 1.0 metre FLUE RESTRICTOR RING (horizontal flue) To ensure maximum efficiency of the appliance, it may be necessary to fit one of the supplied flue restrictor rings to the appliance flue outlet (see tables below). 25 Total flue length Less than 1.2 metre Less than 3.0 metres Less than 4.5 metres 29 Total flue length Less than 2.0 metres Less than 4.0 metres Restrictor required 82.5mm diameter 88mm diameter not required Restrictor required 84mm diameter not required Vertical flue terminal and accessories Part No. Description Min-Max Length 490 Vertical flue terminal 497 Pitched roof flashing plate N/A 498 Flat roof flashing plate N/A m extension 500 mm m extension 1000 mm m extension 2000 mm º bend (pair) N/A º bend N/A 499 Wall bracket N/A Using the dimensions given in fig. 9 as a reference, mark and cut a 107mm hole in the ceiling and/or roof. 35 Total flue length Less than 1.85 metres Restrictor required not required EXTENDING THE FLUE Connect the bend - supplied with the terminal kit - to the top of the boiler using clamp (supplied) see fig. 7. The additional bends & extensions have push-fit connections, care should be taken to ensure that the correct seal is made when assembling the flue system. Connect the required number of flue extensions or bends (up to the maximum equivalent flue length) to the flue terminal (see fig. 7 & 8). The hole should be drilled level to ensure that any condense fluid drains back to the appliance. TE When cutting an extension to the required length, you must ensure that the excess is cut from the plain end of the extension (see fig. 7 & 8). Remove any burrs, and check that all seals are located properly. You must ensure that the entire flue system is properly supported and connected. Seal the flue assembly to the wall using cement or a suitable alternative that will provide satisfactory weatherproofing. Fig FLUE RESTRICTOR RING (vertical flue) To ensure maximum efficiency of the appliance, it may be necessary to fit one of the supplied flue restrictor rings to the appliance flue outlet (see tables below). 25 Total flue length Less than 2.0 metre Less than 4.0 metres Less than 5.5 metres Restrictor required 82.5mm diameter 88mm diameter not required Fig Total flue length Less than 2.8 metres Less than 5.0 metres 35 Total flue length Less than 2.7 metres Restrictor required 84mm diameter not required Restrictor required not required 9
12 Fit the appropriate flashing plate to the roof and insert the vertical flue terminal through the flashing plate from the outside, ensuring that the collar on the flue terminal fits over the flashing. The fixing holes for the wall-mounting bracket should now be drilled and plugged, an appropriate type and quantity of fixing should be used to ensure that the bracket is mounted securely. Once the bracket has been secured to the wall, mount the appliance onto the bracket. IMPORTANT The vertical flue terminal cannot be cut; therefore it may be necessary to adjust the height of the appliance to suit or use a suitable extension. Connect the vertical flue assembly to the boiler flue spigot using the 60mm & 100mm clips, gaskets & screws (supplied), ensuring the correct seal is made. The flue support bracket (supplied with the vertical flue kit) can now be fitted. If the vertical flue requires extension/s or additional bend/s, connect the required number of flue extensions or bends (up to the maximum equivalent flue length) between the boiler and vertical flue assembly (see fig. 8). Ensure that any horizontal sections of the flue system have a minimum 1º fall back to the boiler (17mm per 1000mm). TE When cutting an extension to the required length, you must ensure that the excess is cut from the plain end of the extension (see fig. 8). Remove any burrs, and check that any seals are located properly. You must ensure that the entire flue system is properly supported and connected. 4.6 CONNECTING THE GAS AND WATER The appliance is supplied with an accessory pack that includes service valves. The service valves are of the compression type. The accessory pack contains sealing washers etc, for use with the service valves. When connecting pipe work to the valves, tighten the compression end first then insert the sealing washers before tightening the valve to the appliance. TE It will be necessary to hold the valve with one spanner whilst tightening with another GAS (fig. 6 & 10) The appliance is supplied with a 15mm service valve, connect a 15mm pipe to the inlet of the valve and tighten both nuts. TE It will be necessary to calculate the diameter of the gas supply pipe to ensure the appliance has an adequate supply of gas FLOW & RETURN (fig. 6 & 10) The appliance is supplied with 22mm service valves for the flow and return connections, connect a 22mm pipe to the inlet of each valve and tighten both nuts. TE Depending on system requirements, it may necessary to increase the size of the flow & return pipe work after the service valve connections COLD WATER INLET (fig. 6 & 10) The appliance is supplied with a 15mm stopcock, connect a 15mm pipe to the inlet of the stopcock and tighten both nuts HOT WATER OUTLET (fig. 6 & 10) The appliance is supplied with a 15mm outlet connection, connect a 15mm pipe to the outlet connection and tighten both nuts SAFETY VALVE (fig. 6 & 10) Connect the safety valve connection pipe to the safety valve outlet and tighten. The discharge pipe must have a continuous fall away from the appliance to outside and allow any water to drain away thereby eliminating the possibility of freezing. The discharge pipe must terminate in a position where any water - possibly boiling - discharges safely without causing damage or injury, but is still visible CONDENSE PIPE (fig. 6 & 10) During normal operation the boiler produces condense which is collected in a trap located in the lower part of the boiler. A flexible pipe (condense outlet pipe) is connected to the outlet of the trap. The flexible pipe must be connected to a plastic waste pipe only. The plastic waste pipe must have a minimum of a 3º fall towards the drain. Any external run of pipe should be insulated to prevent the risk of freezing. CONNECTING THE CONDENSATE OUTLET Gently pull the condense outlet pipe down from its location inside the boiler until approximately it protrudes from the underside of the boiler. Connect a suitable plastic (not copper) pipe (no less than 21mm diameter) to the outlet pipe and ensure it discharges in accordance with local building regulations or other rules in force. flow return safety gas DHW valve drain outlet Fig. 10 DHW inlet condense 10
13 4.7 ELECTRICAL CONNECTIONS The boiler is supplied with a 2-metre fly-lead. This lead can be used for connection to the electrical supply. Connect the fly-lead to a fused plug or fused isolator in the following way: brown wire to LIVE supply blue wire to NEUTRAL supply green/yellow to EARTH connection. Insert the supplied 3-AMP fuse into the fused isolator or fused plug. Should the fly-lead be unsuitable, refer to for details on how to connect the electrical supply directly to the boiler. The electrical supply must be as specified in section 3/3A. A qualified electrician should connect the appliance to the electrical supply. If controls - external to the appliance - are required, a competent person must undertake the design of any external electrical circuits, please refer to section 8 for detailed instructions. ANY EXTER- NAL CONTROL OR WIRING MUST BE SERVED FROM THE SAME OLATOR AS THAT OF THE APPLIANCE. The supply cable from the isolator to the appliance must be 3-core flexible sized 0.75mm to BS 6500 or equivalent. Wiring to the appliance must be rated for operation in contact with surfaces up to 90 ºC. Fig. 11 Control panel screws and casing screws A CASING REMOVAL To gain internal access to the appliance you must first remove the casing, proceed as outlined below: locate and unscrew the 3-screws (A) that secure the outer casing to the appliance (see fig. 11) lift the casing upward to disengage it from the top locating hooks and then remove store the casing and screws safely until required. Re-fit in the reverse order gently lower the control fascia until it rests APPLIANCE TERMINAL BLOCK The appliance terminal block is located on the left side of the control fascia (see fig. 11). Locate and remove the screw that secures the terminal block cover. TE The appliance comes with a factory fitted clock to allow basic operation of the boiler. If it is anticipated that additional controls - such as a room Fig. 12 thermostat - will be required please refer to the wiring diagrams in section 8 for more detailed information CONNECTING THE MAINS (230V) INPUT (see fig. 12) Lift the terminal block cover as described in Pass the cable through the cable anchorage point. At the terminal block on the extreme left, there are 3 terminals from left to right they are: LIVE - NEUTRAL - EARTH Connect the supply cable wires (LIVE, NEUTRAL & EARTH) to their corresponding terminals on the appliance terminal block (see fig. 13). Ensure that the EARTH wire is left slightly longer than the others, this will prevent strain on the EARTH wire should the cable become taut. The securing screw on the cable anchorage should now be tightened. This must be done before the control fascia is re-fitted in the upright position. The appliance casing and screws can now be re-fitted. Fig
14 SECTION 5 COMMSIONING 5.1 GAS SUPPLY INSTALLATION Inspect the entire installation including the gas meter, test for soundness and purge. Refer to BS 6891 for specific instruction. 5.2 THE HEATING SYSTEM The appliance contains components that may become damaged or rendered inoperable by oils and/or debris that are residual from the installation of the system, consequently it is essential that the system be flushed in accordance with the following instructions. 5.3 INITIAL FILLING OF THE SYSTEM Ensure both flow and return service valves are open, remove appliance casing as described in 4.7.1, identify the automatic air release valve and loosen the dust cap by turning the cap anticlockwise one full turn. IMPORTANT, THERE ARE MANUAL AIR RELEASE VALVES LO- CATED ON THE APPLIANCE. Ensure all manual air release valves located on the heating system are closed. Connect the filling loop (not supplied) and slowly proceed to fill the system. As water enters the system the pressure gauge will begin to rise. Once the gauge has reached 1 BAR close the filling loop and begin venting all manual air release valves, starting at the lowest first. It may be necessary to go back and top-up the pressure until the entire system has been filled. Inspect the system for water soundness, rectifying any leaks. 5.4 INITIAL FLUSHING The whole of the heating system must be flushed both cold and hot as detailed in 5.8. Open all radiator or heating valves and the appliance flow & return service valves. Drain the boiler and system from the lowest points. Open the drain valve full bore to remove any installation debris from the boiler prior to lighting. Refill the boiler and heating system as described in FILLING THE HOT WATER SYSTEM Close all hot water outlets, turn appliance stopcock to the normal operating position (fully counter clockwise), slowly open each outlet until air has been expelled and clear water is discharged. Check pipe-work etc. for water soundness. 5.6 PRE-OPERATION CHECKS Before attempting the initial lighting of the appliance, the following checks must be carried out: ensure all gas service valves from the meter to the appliance are open and the supply pipe has been properly purged ensure the proper electrical checks have been carried out, (see 7.7) particularly continuity, polarity and resistance to earth ensure the 3 AMP fuse - supplied with the appliance - has been fitted ensure the system has been filled, vented and the pressure set to 1 BAR ensure the flue system has been fitted properly and in accordance with the instructions ensure all appliance service valves are open. 5.7 INITIAL LIGHTING Ensure the electrical supply to the appliance is switched on. Move the selector switch to the Heating & Hot Water position, ensure the time clock is switched to an ON position and ensure any other external controls (room thermostat for example) are also calling for heat. The appliance will now operate in the mode as described in 1.2. Should the appliance fail to ignite, refer to 5.6 and/or section 7 (faultfinding) CHECKING THE BURNER PRESSURE Although the burner pressure is factory set, it is necessary to check it during commissioning. Isolate the appliance from the electrical supply and attach a suitable manometer to the gas valve outlet test-point (see fig. 14). Light the boiler as described in 5.7, turn the Hot Water temperature selector to maximum, and open fully a DHW outlet (preferably the bath), allowing the appliance to stabilise. Compare the reading on the manometer with the value described in 2.3. If adjustment is required, follow the detailed instructions in section 7 (7.3). Outlet test-point Fig. 14 Inlet test-point Protective cap Once the burner pressure has been checked, close the DHW outlet, isolate the appliance from the electrical supply, remove the manometer and tighten the gas valve outlet test nipple. 5.8 FINAL FLUSHING OF THE HEATING SYSTEM The system shall be flushed in accordance with BS Should a cleanser be used, it must be suitable for Copper and Aluminium heat exchangers. It shall be from a reputable manufacturer and shall be administered in strict accordance with the manufacturers instructions and the DWTA code of practice INHIBITORS See section 3 General requirements. 5.9 SETTING THE BOILER OPERATING TEM- PERATURE The flow outlet temperature can be adjusted between 40 ºC - 80 ºC via the Heating thermostat knob (see fig.1). 12
15 5.9.1 SETTING THE DOMESTIC HOT WATER TEM- PERATURE The DHW outlet temperature can be adjusted between 40 ºC - 65 ºC via the Hot Water thermostat knob (see fig.1) SETTING THE SYSTEM DESIGN PRESSURE The design pressure should be a minimum of 1 BAR and a maximum of 1.5 BAR. The actual reading should ideally be 1BAR plus the equivalent height in metres (0.1 BAR = 1 metre) to the highest point in the system above the base of the appliance (up to the maximum of 1.5 BAR total). N.B. The safety valve is set to lift at 3 BAR/30 metres/45 psig.). To lower the system pressure to the required value, water can be drained from the heating system drain cock or from the boiler drain cock REGULATING THE HOT WATER The appliance is fitted with a flow rate restrictor that limits the maximum flow rate that can be drawn through the appliance litre (White) 9-litre (Orange) 10-litre (Blue) Fitted Spare Spare 29 9-litre (Orange) 10-litre (Blue) 11-litre (Beige) Spare Fitted Spare litre (Beige) 12-litre (Red) 13-litre (Olive) Spare Fitted Spare The restrictor eliminates the need to manually adjust the DHW flow rate. However if it is felt necessary to further increase or decrease the available flow rate, spare restrictors are included in the accessory pack. The spare flow rate restrictors can be fitted to either increase or decrease the maximum flow rate. The tables above denote the size of restrictor fitted and the spare restrictors supplied in the accessory pack. Each restrictor is colour-coded to enable identification CHANGING THE FLOW RESTRICTOR Refer to 6.19 for detailed instruction on changing the flow restrictor REGULATING THE CENTRAL HEATING SYS- TEM Fully open all radiator and circuit valves and run the appliance for both heating and hot water until heated water is circulating. If conditions are warm remove any thermostatic heads. Adjust radiator return valves and any branch circuit return valves until the individual return temperatures are correct and are approximately equal FINAL CHECKS ENSURE ALL TEST NIPPLES ON THE AP- PLIANCE GAS VALVE HAVE BEN TIGHT- ENED AND CHECKED FOR SOUNDNESS. ENSURE THE APPLIANCE FLUE SYSTEM FITTED CORRECTLY AND PROPERLY SECURED. ENSURE ALL PIPE WORK RE-CHECKED FOR SOUNDNESS. RE-FIT APPLIANCE CASING. COMPLETE BENCHMARK CHECKLT. Complete details of the boiler, controls, installation and commissioning in the Benchmark checklist at the back of this book. It is important that the Benchmark checklist is correctly completed and handed to the user. Failure to install and commission the appliance to the manufacturers instructions may invalidate the warranty INSTRUCTING THE USER Hand over all documentation supplied with this appliance - including these instructions - and explain the importance of keeping them in a safe place. Explain to the user how to isolate the appliance from the gas, water and electricity supplies, and the locations of all drain points. Show the user how to operate the appliance and any associated controls correctly. Show the user the location of the filling valve and how to top-up the system pressure correctly, and show the location of all manual air release points. Explain to the user how to turn off the appliance for both long and short periods and advise on the necessary precautions to prevent frost damage. Explain to the user that for continued safe and efficient operation, the appliance must be serviced annually by a competent person. 13
16 SECTION 6 SERVICING INSTRUCTIONS 6.1 GENERAL To ensure the continued safe and efficient operation of the appliance, it is recommended that it is checked and serviced at regular intervals. To ensure correct and safe operation of the appliance, it is essential that any worn or failed component be replaced only with a genuine spare part. The frequency of servicing will depend upon the particular installation conditions, but in general, once per year should be adequate. It is the law that any servicing work is carried out by competent person such as an engineer, an approved service agent, British Gas, CORGI registered personnel or other suitably qualified personnel. The following instructions apply to the appliance and its controls, but it should be remembered that the central heating and the domestic hot water systems would also require attention from time to time. 6.2 ROUTINE ANNUAL SERVICING Check the operation of the appliance and ensure it functions as described in section 7. Compare the performance of the appliance with its design specification. The cause of any noticeable deterioration should be identified and rectified without delay. Thoroughly inspect the appliance for signs of damage or deterioration especially the flue system and the electrical apparatus. Check and adjust - if necessary - all burner pressure settings (see section 7.3). Check and adjust - if necessary - the system design pressure (see section 5.10). Carry out an analysis of the flue gases (see 7.4) and visually check the condition of the entire flue assembly. Compare the results with the appliance design specification. Any deterioration in performance must be identified and rectified without delay. Ensure both flue venturis are clean and free from any debris or obstruction. Ensure the burner, main heat exchanger and latent heat collector are clean and free from any debris or obstruction. 6.3 MENT OF COMPONENTS Although it is anticipated that this appliance will give years of reliable, trouble free service, the life span of components will be determined by factors such as operating conditions and usage. Should the appliance develop a fault, the fault finding section will assist in determining which component is malfunctioning. 6.4 COMPONENT REMOVAL PROCEDURE To remove a component, access to the interior of the appliance is essential. Isolate the appliance from the electrical supply and remove the fuse. And when necessary, close all service valves on the appliance, remove the appliance casing as described in section and drain the water content from the appliance via the drain valve located at the front of the hydraulic section using the tube provided. Ensure some water absorbent cloths are available to catch any residual water that may drip from the appliance or removed component. Undertake a complete commissioning check as detailed in section 5, after replacing any component. ALWAYS TEST FOR GAS SOUNDNESS IF ANY GAS CARRYING COM- PONENTS HAVE BEEN REMOVED OR D- TURBED. 6.5 PUMP ASSEMBLY fig. 15 The pump head can be replaced by disconnecting the electrical connection at the pump and removing the 4-Allen screws that secure the head to the pump base. Alternatively, the complete pump assembly can be removed as follows: disconnect the electrical connection from the pump control box locate and remove the pressure gauge securing pin and disconnect the pressure gauge from the pump assembly locate and remove the expansion pipe securing pin and disconnect the expansion pipe from the pump assembly locate and remove the condense pipe located between the air-chamber and condense trap refer to fig. 15, disconnect and remove items A, B & C locate and remove securing pin F and lift the pump assembly away from the hydraulic section. Replace in the reverse order. Fig. 15 A C 6.6 SAFETY VALVE fig. 16 Disconnect and remove the safety valve outlet pipe. Locate and remove the safety valve securing pin (B). The safety valve can now be removed. Replace in the reverse order. G F B 14
17 B 6.11 HIGH LIMIT THERMOSTAT fig. 18 Unclip and remove the air chamber cover. Pull off electrical connections from the high limit thermostat (2), slacken and remove retaining screws (3). Replace in reverse order. Fig. 16 E 6.7 AUTOMATIC AIR RELEASE VALVE fig. 15 (AAV) Locate and remove the expansion pipe securing pin and disconnect the expansion pipe from the pump assembly. Locate and remove the AAV securing pin (G) and lift the AAV free from the pump assembly. Replace in the reverse order. 6.8 WATER PRESSURE SWITCH fig. 1 Disconnect the 2-wires from the water pressure switch, taking note of their locations. Locate and remove the pin that secures the water pressure switch to the flow pipe. Remove the water pressure switch from the flow pipe. Replace in the reverse order. 6.9 PRESSURE GAUGE fig. 1 Locate and remove the pressure gauge securing pin and disconnect the pressure gauge from the pump assembly. Locate the spring tabs on the pressure gauge body, push and hold tabs in, to enable extraction of the gauge from its location on the control panel. Replace in the reverse order PRIMARY THERMTOR fig. 17 Unclip and remove the air chamber cover and remove the right side air baffle. Disconnect thermistor electrical plug. Using a 13mm spanner slacken and remove the thermistor and sealing washer (1,2) from the main heat exchanger. Replace in the reverse order. Fig PRINTED CIRCUIT BOARD fig. 19 Locate and remove the screws that secure the PCB cover, then remove cover. After carefully taking note of all wiring connections, disconnect all wiring from the PCB, locate and remove the PCB securing screws (2,3,), remove the required PCB (Main or ignition control). Replace in the reverse order. TE Ensure that any replacement PCB has the correct jumper tag configuration, and that the relevant gas pressures are correctly set/adjusted (see 7.8.1) GAS VALVE fig. 20 The gas valve must be changed as complete unit. Disconnect the electrical plug and leads from the gas valve. Slacken and unscrew gas valve inlet and outlet connections (3). Please note, the sealing washers (2) must be discarded and replaced with new sealing washers (2). Locate and remove gas valve retaining screws on the underside of the boiler if required. The gas valve can now be removed. Replace in the reverse order. Check and adjust burner pressure settings. WARNING, A GAS SOUNDNESS CHECK MUST BE CAR- RIED OUT. Fig
18 M CLK-1 CLK-4 M Fig. 19 Fig INTEGRAL TIME SWITCH (if fitted) Locate and remove the PCB cover and securing screws (fig. 19/19A), locate and remove the time clock retaining screws, remove time clock. Disconnect wiring after carefully taking note of all electrical connections. Replace in the reverse order. Fig. 19a 6.15 ELECTRODE, BURNER THERMOSTAT, BURNER & INJECTORS fig. 21 Unclip and remove the air chamber cover (2). Locate and remove the 6 screws securing the front combustion cover (3), pull the cover towards you before lifting and disengaging. Disconnect the electrode lead and burner thermostat from their respective connectors. Ease the electrode sealing grommet from its seating (4). Remove the retaining screw for the burner thermostat and remove the thermostat. FIG. 22: locate and remove the four screws which secure the burner in position (1), gently ease the burner out of its location. Once the burner has been removed, the electrode retaining screw can be removed. Locate the burner injectors (2) and remove (if necessary). Replace in the reverse order. Please note, the injector sealing washers (3) must be replaced if the injectors have been removed, ensure all seals are in good condition, taking care to ensure they are replaced correctly. Replace in the reverse order. Fig. 21 Fig
19 Fig FLUE FAN fig. 23 Unclip and remove the air chamber cover, gently pull the cover towards you before lifting and disengaging. Locate and remove the six screws that secure the front combustion cover, then remove the cover. Disconnect the electrical connections and silicone tubes attached to the fan, noting their positions. Locate and remove the screws (6) that secure the air pressure switch assembly (4 & 5). Locate and remove the screws that secure the flue hood and air baffle, disconnect the flue clip (1) from the fan-flue elbow, and gently ease the fan (3) & flue hood assembly (2) from its location. Locate and remove the four screws that secure the fan to the flue hood. Remove the fan to flue elbow. Replace in the reverse order. Ensure all seals are in good condition, taking care to ensure they are replaced correctly. panels if necessary by unscrewing the securing screws. Disconnect the flow and return connections (4,5, fig. 24) on the heat exchanger. The heat exchanger can now be withdrawn from the appliance. Replace in the reverse order. Ensure all seals are in good condition, taking care to ensure they are replaced correctly AIR PRESSURE SWITCH fig. 23 Unclip and remove the air chamber cover, gently pull the cover towards you before lifting and disengaging. Locate and remove the two screws (6) holding the air pressure switch to the air chamber. Disconnect the electrical connections and silicone tubes (10) attached to the air pressure switch, noting their connections/positions. Replace in the reverse order. Ensure all seals are in good condition, taking care to ensure they are replaced correctly. A B Fig MAIN HEAT EXCHANGER fig. 23/24 Unclip and remove the air chamber cover, gently pull the cover towards you before lifting and disengaging. Locate and remove the six screws that secure the front combustion cover, then remove the cover. Remove the air chamber side Fig FLOW RESTRICTOR fig. 25 Carry out the component removal procedure as described Slacken the cold water inlet pipe (A) at the DHW flow switch and disconnect. Ease the flow restrictor (B) from its seating. Replace in the reverse order. Ensure all seals are in good condition, taking care to ensure they are replaced correctly. 17
20 6.20 DHW FLOW SWITCH fig. 25 Disconnect the cold water inlet pipe (A) from the DHW flow switch. Disconnect the wiring to the DHW flow switch. Remove the locking pin from the DHW flow switch and lift the DHW flow switch from its location. Replace in the reverse order. Ensure all seals are in good condition, taking care to ensure they are replaced correctly DHW HEAT EXCHANGER fig. 16 Before removing the DHW heat exchanger, it may be necessary to first remove the pump assembly and condense trap. Locate and remove the screws (E) that secure the heat exchanger to the DHW manifolds. Carefully remove the heat exchanger from its location taking care not to spill any residual water. Replace in the reverse order ensuring that the heat exchanger O ring seals are correctly inserted into the DHW manifolds. Ensure all seals are in good condition, taking care to ensure they are replaced correctly. Fig. 26 Fig. 26a 6.22 VALVE ACTUATOR fig. 26 Remove the locking pin (A) that secures the actuator (B) to the hydraulic manifold. Disconnect the electrical plug from the actuator. Replace in the reverse order DIVERTOR VALVE CARTRIDGE fig. 26 Remove the valve actuator as described in Remove the cartridge locking pin (C) and - using a suitable pair of pliers - withdraw the cartridge Fig. 27 assembly. The cartridge assembly is a nonserviceable item and therefore needs to be replaced if it s suspected as being damaged or worn. Replace in the reverse order ensuring that the seating cam inserts into the locating groove correctly (see fig. 26a). Ensure all seals are in good condition, taking care to ensure they are replaced correctly. A F C D 6.24 DHW THERMTOR fig. 27 Disconnect the electrical plug. Using a suitable pair of pliers, remove the thermistor locking pin (E) and ease the thermistor (F) from its seating. Replace in the reverse order ensuring the sealing ring is in good condition AUTOMATIC BY-PASS fig. 27 Locate and remove the hydraulic cover locking pin (A) and remove the cover. Using a suitable hooked wire or screwdriver, gently ease the nonreturn valve (C) from its seating. Ensure all seals are in good condition, taking care to ensure they are replaced correctly. Replace in the reverse order ensuring the cartridge is facing the correct way DHW N-RETURN VALVE fig. 27 Locate and remove the hydraulic cover locking pin (A) and remove the cover. Using a suitable hooked wire or screwdriver, gently ease the nonreturn valve (D) from its seating. Ensure all seals are in good condition, taking care to ensure they are replaced correctly. Replace in the reverse order ensuring the cartridge is facing the correct way EXPANSION VESSEL fig. 1 Should the removal and replacement of the expansion vessel be deemed impractical, an external expansion vessel may be fitted to the return pipe as close to the appliance as possible EXPANSION VESSEL REMOVAL (with sufficient clearance above) Disconnect the flue from the appliance. E 18
21 B Disconnect the flexible expansion pipe from the vessel. Locate and remove the four screws (A) that secure the vessel top holding plate (B), remove the plate (fig. 28). The expansion vessel can now be removed. Replace in the reverse order. Ensure all seals are in good condition, taking care to ensure they are replaced correctly. A the collector from the flue connection. Replace in the reverse order ensuring all seals are intact and located correctly DMANTLING THE LATENT HEAT COLLEC- TOR Apart from routine servicing or maintenance of the coil, the latent heat collector is a non-serviceable component, therefore, there is no requirement to disassemble the collector CONDENSE TRAP REMOVAL fig. 31 Disconnect the flexible condense pipe (1) from the condense trap. Locate and remove the condense pipe locking pin and disconnect the condense pipe (2) from the condense trap. Locate and disconnect the condense pressure switch pipe from the condense trap (3). Carefully remove the condense trap. Replace in the reverse order. Fig EXPANSION VESSEL REMOVAL (with insufficient clearance above) Disconnect the flexible expansion pipe from the vessel. Disconnect the flue elbow or pipe from the appliance flue outlet. Unclip and remove the air chamber cover, gently pull the cover towards you before lifting and disengaging. Remove the RH side panel of the air chamber. Disconnect the wiring to the fan, pressure switch, primary thermistor, overheat thermostat, condense switch & spark electrode, taking note of their locations. Carefully unclip the wires from the air chamber and withdraw the wiring & grommet from the air chamber. Disconnect the outlet gas pipe, the flow & return pipes and the condense pipe from the air chamber. Locate and remove the 2-screws that secure the lower section of the air chamber. Locate and remove the 2-screws that secure the upper section of the air chamber. The complete air chamber assembly can now be lifted clear from the appliance. Locate and remove the 4-screws that secure the vessel (see fig. 28). The expansion vessel can now be removed. Replace in the reverse order. Take extreme care when refitting the wiring to the air chamber. Ensure all seals are in good condition, taking care to ensure they are replaced correctly LATENT HEAT COLLECTOR fig. 29/30 Remove the flue hood and fan assembly as detailed in Disconnect and remove the inlet, outlet and condense pipes from the collector. Unscrew and remove the 3 screws that secure the collector to the air chamber and disconnect Fig. 29 Fig. 30 Fig
22 SECTION 7 CHECKS, ADJUSTMENTS AND FAULT FINDING 7.1 CHECKING APPLIANCE OPERATION When carrying out any repairs or servicing to the appliance, the relevant commissioning procedure must be undertaken to ensure the continued safe operation of the appliance. Particular attention should be made to ensure gas soundness, water soundness and the electrical integrity of the appliance. 7.2 APPLIANCE MODE OF OPERATION TE There must be sufficient system water pressure (min. 0.5 bar) to ensure the water pressure switch is activated. If there is insufficient system pressure the pump and fan will be prevented from operating SELECTOR SWITCH IN THE OFF POSITION When the selector switch is in the OFF position, the Green LED status indicator will flash every 6- seconds to confirm the appliance is in standby mode. The divertor valve is in the DHW position. The appliance will not respond to any DHW or heating requests. Active functions: frost-protection system pump anti-block valve actuator anti-block fan over-run SELECTOR SWITCH IN THE HOT WATER ONLY POSITION When the selector switch is in the HW only position, the Green LED is illuminated: flashing every 6-seconds if no DHW request is active constant during a DHW request. The divertor valve is in the DHW position. The appliance will respond to any DHW requests. Active functions: frost-protection system pump anti-block valve actuator anti-block fan over-run SELECTOR SWITCH IN THE HEATING & HOT WATER POSITION When the selector switch is in the heating & HW position, the Green LED is illuminated: flashing every 6-seconds if no Heat or DHW request is active constant during a heat or DHW request. The divertor valve remains in the DHW position if no heat request is active. The appliance will respond to any heating or DHW requests. Active functions: frost-protection system pump anti-block valve actuator anti-block fan/pump over-run APPLIANCE FUNCTIONS Frost-protection: this function is only active when there are no requests for heating or HW. When the temperature of the primary thermistor drops below 5 C, the valve actuator will motor to the heating position, whereupon the boiler will operate on minimum power until the temperature of the primary thermistor reaches 35 C. Thereafter the pump will over-run for 30- seconds. Anti-block cycle: when there has been no heating or HW request for 19-hours, the antiblock cycle is activated. The valve actuator will motor from the DHW position to the heating position and then motor back to the DHW position. Thereafter the pump will be activated for a period of 30-seconds. Fan over-run: should the temperature of the primary thermistor exceed 78 C after a heating or DHW request, the pump and/or fan will run for a period of 30-seconds. SARA function: the SARA function permits the boiler (when the set-point is within the SARA range) to automatically adjust (raise) the heating flow outlet temperature should the room thermostat contacts remain closed for more that 20-minutes DHW MODE fig. 32 With the selector switch in the Heating & HW position, or HW only position and a DHW outlet is opened, the appliance will operate in the HW mode. The valve actuator will motor to the HW position (if a heating request was active) and the pump and fan will be active. The operation of the fan causes the air pressure switch to deliver a signal voltage to the control PCB. A slow ignition sequence is enabled, whereby the current supplied to the gas valve modulating coil is progressively increased from minimum to maximum over a period of 8-seconds. During this period the ignition electrode sparks continuously even if the burner has ignited. 20
23 of the fan causes the air pressure switch to deliver a signal voltage to the control PCB. A slow ignition sequence is enabled, whereby the current supplied to the gas valve modulating coil is progressively increased from minimum to maximum over a period of 8-seconds. During this period the ignition electrode sparks continuously even if the burner has ignited. Fig. 32 TE If the spark/sensing electrode does not sense ignition the appliance will then go to lockout. Ignition is sensed by the electronic circuitry to ensure flame stability at the burner. Once successful ignition has been achieved, the electronic circuitry modulates the appliance output in order to achieve the DHW set-point (the position of the DHW temperature selector) as measured at the secondary thermistor. When the set-point has been reached, the appliance will begin the modulation phase whereby the fan and gas valve will continuously modulate to maintain the set-point. If the temperature continues to rise and exceeds the set-point by 5 C, the burner will shut down until the temperature drops to set-point + 4 C, whereby a new ignition sequence will be enabled. When the request for DHW has been satisfied, the appliance fan may continue to operate to dissipate any residual heat from within the appliance DHW PARAMETERS RANGE MINIMUM MAXIMUM Temperature ( C) DHW NTC fault ON at 50 C OFF at 55 C HEATING MODE fig. 33 With the selector switch in the Heating & HW position and the relevant controls (time clock, room thermostat, etc,) are calling for heat, the appliance will operate in the heating mode. The valve actuator will motor to the heating position and the pump and fan will be active. The operation Fig. 33 TE If the spark/sensing electrode does not sense ignition the appliance will then go to lockout. Ignition is sensed by the electronic circuitry to ensure flame stability at the burner. Once successful ignition has been achieved, the electronic circuitry allows 75% of the full gas rate through the appliance. After 15 minutes the gas rate is increased to maximum (100%). When the set-point has been reached (the position of the heating temperature selector) as measured at the primary thermistor, the appliance will begin the modulation phase whereby the fan and gas valve will continuously modulate to maintain the set-point. If the temperature continues to rise and exceeds the set-point by 6 C, the burner will shut down and the boiler will perform a three-minute anti-cycle (timer delay). A new ignition sequence will be enabled when the 3-minute anti-cycle has been performed and the temperature at the primary thermistor has dropped 6 C below the set-point. TES The timer delay can be de-activated by the insertion of a jumper on the PCB at JP1 or by isolating the appliance from the electrical supply for 30 seconds. Any DHW requests will always have priority over a heating request. When the request for heating has been satisfied, the appliance pump and fan may continue to circulate to dissipate any residual heat within the appliance. 21
24 HEATING PARAMETERS RANGE MINIMUM MAXIMUM Temperature ( C) ST sector SARA sector ND sector When the boiler is operating in the SARA range, the Green LED flashes rapidly to signify the SARA function is active. SARA FUNCTION When the heating temperature selector is set within the SARA range (SARA sector) the boiler will automatically raise the heating flow outlet temperature by 5 C every 20-minutes that the room thermostat contacts remain in the closed position or until the boiler reaches the maximum operating temperature. 7.3 CHECKING AND ADJUSTING BURNER PRESSURE (see fig. 15) Although the burner pressure is factory set, it is necessary to check it during servicing or if the gas valve has been removed. Isolate the appliance from the electrical supply and attach a suitable manometer to the gas valve outlet test nipple. Fig. 34 Fig SETTING THE MAXIMUM BURNER PRESSURE fig. 39 Light the boiler as described in 5.7 and compare the reading on the manometer with the value described in 2.3. If adjustment is required, remove the protective cap from the gas valve modulating coil assembly and turn the outer (10mm) nut clockwise to increase, or counterclockwise to decrease the burner pressure. TE Always check and/or adjust the minimum and maximum gas pressures whilst the appliance is in the HW only mode. Ensure a DHW outlet (preferably the bath) is fully open, and that the HW temperature selector is at maximum SETTING THE MIMIMUM BURNER PRES- SURE fig. 34 Once the maximum burner pressure has been checked and/or adjusted, remove one of the grey wires from the modulating coil. Compare the reading on the manometer with the value described in 2.3. If adjustment is required, turn the inner (red) crosshead screw clockwise to increase, or counter-clockwise to decrease the burner pressure, whilst ensuring that the outer (10mm) nut does not move. When checking and/ or adjustment has been completed, isolate the appliance from the electrical supply, replace the protective cap, refit the grey wire to the modulating coil, remove the manometer and tighten the outlet test nipple. IMPORTANT, A GAS SOUNDNESS CHECK MUST BE CARRIED OUT SETTING THE MINIMUM CENTRAL HEATING OUTPUT TH CAN ONLY BE CARRIED OUT AFTER THE MAXIMUM AND MINIMUM GAS PRES- SURES HAVE BEEN SET. Isolate the appliance from the electrical supply. Attach a manometer to the gas valve outlet test nipple. Insert a jumper tag at JP2. Switch the appliance ON in the heating mode. Turn potentiometer P5 to the minimum position Adjust potentiometer P4 to the required value shown in section2.3 (section 10.2 for LPG), i.e. minimum burner pressure (central heating). Turn potentiometer P5 back to the maximum position. Isolate the appliance from the electrical supply. Remove the manometer, tighten the outlet test nipple, and check for soundness. 7.4 COMBUSTION ANALYS TEST A combustion analysis check can easily be carried out on the appliance via the test points located on the top of the appliance, however you must check that the burner pressures are set correctly (see 7.3). Isolate the appliance from the electrical supply and turn the mode selector switch to the OFF/ RESET position. Locate and remove the CO test point sealing screw (see fig. 36). Insert the flue gas analyser probe into the test point. Restore the electrical supply to the appliance Remove the mode selector knob and turn the shaft fully clockwise (see fig. 37). 22
25 The boiler will now enter the combustion analysis mode (CO mode) for a period of 15 minutes, signified by the LED flashing Yellow. During this time, the boiler will remain on full gas. Once the flue gas analysis has been made, turn the shaft back to the required position and replace the mode selector knob. Remove the probe and replace the sealing screw. 7.5 CHECKING THE EXPANSION VESSEL Air analysis outlet GREEN LED Frequency ON every 6-secs Flashing 8-times a second ON every 0.5-secs YELLOW LED Fumes analysis outlet Frequency Faults/Status ON every 0.5-secs CO function active Solid DHW thermistor fault (see ) RED LED Solid Faults/Status At stand-by with no faults SARA function active Temporary fault, e.g.: APS fault low water pressure Active for heat/dhw request Fig. 36 Fig. 37 Carry out the component removal procedure as described You must ensure that the boiler is completely drained of water. Using a suitable pressure gauge, remove dust cap on expansion vessel and check the charge pressure. The correct charge pressure should be 1.0 bar ± 0.1 bar. If the charge pressure is less, use a suitable pump to increase the charge. TE You must ensure the drain valve is in the open position whilst re-charging takes place. Replace the dust cap and carry out the relevant commissioning procedure (section 5). 7.6 EXTERNAL FAULTS Before carrying out any faultfinding or component replacement, ensure the fault is not attributable to any aspect of the installation INSTALLATION FAULTS Symptom No ignition No hot water No central heating Possible causes Check wiring Check electrical supply Check hot/cold pipe work is not reversed Check wiring of room thermostat and/or other external controls Frequency ON every 0.5-secs Solid Faults/Status Final fault, e.g.: water pressure switch condense pressure switch fan/flue problem limit thermostat primary NTC open/short circuit 7.7 ELECTRICAL CHECKS Any electrical checks must be carried out by a suitably qualified person EARTH CONTINUITY TEST Isolate the appliance from the electrical supply, and using a suitable multi-meter carry out a resistance test. Connect test leads between an appliance earth point and the earth wire of the appliance supply cable. The resistance should be less than 1 OHM. If the resistance is greater than 1 OHM check all earth wires and connectors for continuity and integrity SHORT CIRCUIT CHECK Isolate the appliance from the electrical supply, and using a suitable multi-meter, carry out a short circuit test between the Live & Neutral connections at the appliance terminal strip (fig.12). Repeat above test on the Live & Earth connections at the appliance terminal strip (fig.12). TE Should it be found that the fuse has failed but no fault is indicated, a detailed continuity. Check will be required to trace the fault. A visual inspection of components may also assist in locating the fault POLARITY CHECK With the appliance connected to the electrical supply and using a suitable multimeter, carry out the following voltage tests: Connect test leads between the Live & Neutral connections at the appliance terminal strip (fig.12). The meter should read approximately 230V ac. If so proceed to next stage. If not, see Connect test leads between the Live & Earth connections at the appliance terminal strip (fig.12). The meter should read approximately 230V ac. If so proceed to next stage. If not, see Connect test leads between the Neutral & Earth connections at the appliance terminal strip (fig.12). The meter should read approximately 0-15Vac. If so polarity is correct. If not, see
26 7.7.4 REVERSED POLARITY OR SUPPLY FAULT Repeat the above tests at the appliance isolator, if testing reveals correct polarity and/or supply at the isolator, re-check wiring and connections between the isolator and the appliance. If tests on the isolator also reveal reversed polarity or a supply fault, consult the local electricity supplier for advice RESTANCE TO EARTH CHECK Isolate the appliance from the electrical supply and using a suitable multi-meter carry out a resistance test. Connect test leads between the Live & Earth connections at the appliance terminal strip (fig.12). If the meter reads other than infinity there is a fault that must be isolated, carry out a detailed continuity check to identify the location of the fault. IMPORTANT These series of checks must be carried out before attempting any faultfinding procedures on the appliance. On completion of any task that required the disconnection and re-connection of any electrical wiring or component, these checks must be repeated. 7.8 FAULT FINDING Before attempting any faultfinding, the electrical checks as detailed in 7.7 must be carried out. Isolate the appliance from the electrical supply. Disconnect any external controls such as room thermostats etc. from the boiler REPLACING THE MAIN PCB When replacing the main PCB it s essential that the potentiometers are set as follows: It s essential that the minimum - central heating - gas pressure is checked/adjusted as described in P4 - to be used to set/adjust the minimum heating output P5 - set at maximum. EFFECT OF JUMPER TAGS FITTED TO THE MAIN PCB AT: JP1 - disables DHW function JP2 - cancels anti-cycle function and initial heating output (75% of maximum at start up) JP3 - for LPG boilers only JP4 - enables DHW temperature stabiliser function (boiler modulates at set point and remains on minimum power, even if the set point is exceeded). Restore the electrical supply to the boiler and turn the selector switch to the on position. The boiler should now function as described in section 7.2. Should the boiler fail to respond, the internal fuses and connectors should be checked to ensure integrity and continuity. If the boiler still fails to respond, refer to the detailed faultfinding flowcharts overleaf. 7.9 FAULT CODES When the boiler is in a fault condition, the LED is displayed in a colour and/or frequency that is relevant to the fault. To reset the boiler, turn the mode selector switch to the reset position (0) for 2-minutes then back to the relevant mode of operation. If the boiler does not reset, refer to the following section and the detailed faultfinding flowcharts overleaf. YELLOW LED Frequency Faults/Status ON every 0.5-secs CO function active Solid DHW* thermistor fault (see ) * When there is a fault condition with the DHW thermistor, the appliance will still operate and produce limited hot water. The Primary thermistor will control the temperature of the DHW during this period and the outlet temperature is fixed at o C. RED LED Frequency ON every 0.5-secs Solid Faults/Status Final fault, e.g.: water pressure switch condense pressure switch fan/flue problem limit thermostat primary NTC open/short circuit 24
27 FAULT FINDING TEST A : CHECKING OPERATION OF ELECTRONIC CONTROL BOARD AT START UP START SWITCH ON BOILER AND SELECT MODE TO WINTER C/H THERMOSTAT AT MAX. MADE A LINK BETWEEN BLACK & BLACK WIRES AT BOILER TERMINAL STRIP AND CLOSE THE TIMER CONTACT GREEN LED BLINKS A1 PUMP RUNNING MAINS ON PUMP CONNECTOR CN2.1 & CN2.2 ON PCB FAN RUNNING MAINS ON PUMP A LOOSE THE PUMP ACTING WITH A SCREWDRIVER ON THE IMPELLER WIRING OR CONNECTIONS MAINS ON FAN RESTART THE TEST THERE 24dc BETWEEN TERMINALS CN9.1 & CN9.2 ON PCB WATER PRESSURE SWITCH/ CONDENSE PRESSURE SWITCH ARE OK CHECK WIRING AND CONNECTIONS OR WATER PRESSURE SWITCH/ CONDENSE PRESSURE SWITCH PUMP RUNNING CONTROL BOARD CHECK IDRAULIC CIRCUIT PUMP MAINS BETWEEN PIN CN1.4 & CN1.5 ON PCB CHECK &/OR WIRING AND CONNECTIONS ROOM THERMOSTAT INPUT LINKED CHECK WIRING OR CONNECTIONS BETWEEN TERMINAL STRIP AND CONTROL BOARD MAINS ON FAN CONNECTOR CN4.1 & CN4.2 ON PCB MADE A LINK BETWEEN THE ROOM THERMOSTAT INPUT THERE 24dc BETWEEN TERMINALS CN8.3 & CN8.5 ON PCB CONTROL BOARD RESTART THE TEST AIR FLOW SWITCH OFF? WIRING OR CONNECTIONS FAN THERE 0 VCC BETWEEN TERMINALS CN8.3 & CN8.5 ON PCB CONTROL BOARD AIR FLOW SWITCH OR CHECK FLUE GAS TUBE 25
28 FAULT FINDING TEST A A SPARK AT ELECTRODE END SENSING/SPARK ELECTRODE AND LEAD THERE 0 Vdc BETWEEN TERMINALS CN8.7 & CN8.8 ON PCB SENSING SPARK ELECTRODE AND LEAD OK IGNITION LOCKOUT AFTER IGNITION CHEK SENSING/SPARK ELECTRODE AND LEAD PCB THERE 230 Vac BETWEEN TERMINALS CN5.1 & CN5.2 ON PCB THE CONTROL BOARD CHECK AND/OR PCB THERE 24 Vdc BETWEEN TERMINALS CN8.4 & CN8.5 ON PCB MAINS ON E.V.G. THERE 24 Vdc BETWEEN TERMINALS CN8.4 & CN8.8 ON PCB CHECK WIRING AND CONNECTIONS OR HIGH LIMIT THERMOSTAT CHECK WIRING AND CONNECTIONS, AIR FLOW SWITCH AND CONTROL BOARD CHECK/CLEAN THE VENTURI TUBE AND SILICONE AIR TUBES THERE 230 Vac BETWEEN TERMINALS CN6.1 & CN6.2 ON PCB CHECK AND/OR PCB THERE 24 Vdc BETWEEN TERMINALS CN8.4 & CN8.7 ON PCB CHECK AIR FLOW SWITCH CHECK SENSING/SPARK ELECTRODE AND LEAD DO THE AIR FLOW SWTCH TURN ON ARE THE VENTURI TUBE AND THE SILICONE AIR TUBES CLEAN THE AIR DP > 11 mmch2o CHECK WIRING AND CONNECTIONS OR HIGH LIMIT THERMOSTAT CHECK WIRING AND CONNECTIONS EVG OK CHECK THE FAN AND/OR FLUE GAS TUBE EVG CHECK GAS 26
29 FAULT FINDING TEST A1 A1 RED LED BLINKS CONTROL BOARD RED LED LIGHT YELLOW LED LIGHT RESTART THE TEST SWITCH ON/OFF SELECTOR ON OFF POSITION SWITCH ON/OFF SELECTOR TO WINTER POSITION GREEN LED BLINKS CHECK CH NTC SENSOR OR WIRING AND CONNECTIONS WIRING OR CONNECTIONS TERMINAL STRIP AND CONTROL BOARD CHIMNEY SWEEPER CYCLE. RESET AND RESTART TEST MAINS PRESENT BETWEEN BLUE & BROWN WIRES AT BOILER TERMINAL STRIP YELLOW LED BLINKS RECHECK SUPPLY FUSE & CONNECTORS TO BOILER TERMINALS MAINS PRESENT BETWEEN TERMINALS CN1.2 &CN1.3 M2.2 ON CONTROL BOARD CHECK FUSE F1 ON CONTROL BOARD THERE 24 Vdc BETWEEN TERMINALS CN8.4 & CN8.6 ON PCB THERE 24 Vdc BETWEEN TERMINALS CN8.4 & CN8.5 ON PCB CHECK WIRING AND CONNECTIONS OR AIR PRESSURE SWITCH THERE 24 Vdc BETWEEN TERMINALS CN8.4 & CN8.7 ON PCB CONTROL BOARD THERE 24 Vdc BETWEEN TERMINALS CN8.4 & CN8.8 ON PCB CHECK WIRING AND CONNECTIONS OR HIGH LIMIT THERMOSTAT CONTROL BOARD THERE 0 VCC BETWEEN TERMINALS CN9.1 & CN9.2 ON PCB CONTROL BOARD CONTROL BOARD CHECK WIRING AND CONNECTIONS, WATER PRESSURE SWITCH AND HYDRAULIC CIRCUIT FUSE OK FUSE RESTART THE TEST 27
30 FAULT FINDING TEST B2 : CHECK CONTROL IN DHW MODE START CHECK OR THE ELECTRICAL 3 WAY MIXING VALVE, CABLES AND CONNECTIONS SWITCH ON BOILER AND SELECT MODE TO SUMMER. DHW THERMOSTAT AT MAX. THERE 24 Vdc BETWEEN TERMINALS CN9.7 & CN9.8 ON PCB PCB THERE 230 Vac BETWEEN CN3.1 AND CN3.3 ON THE PCB TURN ON TAP DOES BURNER LIGHT DHW FLOW SWITCH OK? CHECK BOILER STARTUP: TEST A 3 WAY MIXING VALVE IN DHW POSITION CONTROL BOARD THERE A VOLTAGE >10 VDC BETWEEN TERMINALS CN9.3 & CN9.4 ON PCB VOLTAGE ACROSS TERMINALS OF MODULATOR COIL > 10 VDC CHECK WIRING AND CONNECTIONS OR DHW SWITCH THE RESTENCE OF MODULATOR COIL ABOUT 70/80 OHM WAIT TILL THE VOLTAGE BETWEEN TERMINAL CN9.3 & CN9.4 ON PCB < 1.2 Vdc WAIT D.H.W. TEMPERATURE >60 C MODULATOR COIL WIRE AND CONNECTIONS CONTROL BOARD THE VOLTAGE BETWEEN TERMINAL CN9.3 & CN9.4 ON PCB < 1.2 Vdc SWITCH DHW THERMOSTAT AT MIN. D.H.W. TEMPERATURE >60 C WAIT D.H.W. TEMPERATURE >40 C D.H.W. TEMPERATURE >40 C DO BURNER AND FAN SWITCH OFF D.H.W. NTC OK CONTROL BOARD D.H.W. NTC CONTROL BOARD B 28
31 FAULT FINDING TEST C : CHECK CONTROL IN C/H MODE START SWITCH ON BOILER AND SELECT MODE TO WINTER C/H THERMOSTAT AT MAX. MADE A LINK BETWEEN BLACK & BLACK WIRES AT BOILER TERMINAL STRIP AND CLOSE THE TIMER CONTACT DOES BURNER LIGHT VOLTAGE ACROSS TERMINALS OF MODULATOR COIL >10 VDC THERE A VOLTAGE <8 VDC BETWEEN TERMINALS CN9.3 & CN9.4 ON PCB CONTROL BOARD VOLTAGE ACROSS TERMINALS OF MODULATOR COIL < 8 VDC TIMER JUMPER ON REMOVE JUMPER RESTART THE TEST WAIT TILL THE VOLTAGE BETWEEN TERMINAL CN9.3 & CN9.4 ON PCB < 1.2 Vdc CHECK BOILER STARTUP TEST A SET TIMER JUMPER ON VOLTAGE ACROSS TERMINALS OF MODULATOR COIL >10 VDC CONTROL BOARD WIRE AND CONNECTIONS THE VOLTAGE BETWEEN TERMINAL CN9.3 & CN9.4 ON PCB < 1.2 Vdc WAIT D.H.W. TEMPERATURE >80 C SWITCH CH THERMOSTAT AT MIN. THE RESTENCE OF MODULATOR COIL ABOUT 70/80 OHM MODULATOR COIL CONTROL BOARD C C.H. NTC D.H.W. TEMPERATURE >80 C C.H. NTC OK CONTROL BOARD 29
32 TEST C CONT D C DO BURNER AND FAN SWITCH OFF WAIT WATER FLOW TEMPERATURE >40 C SWITCH CH THERMOSTAT AT MAX. WATER FLOW TEMPERATURE >40 C CONTROL BOARD DO BURNER AND FAN SWITCH ON TIMER JUMPER ON WAIT 3 MIN. CONTROL BOARD REMOVE JUMPER RESTART THE TEST DO BURNER AND FAN SWITCH ON WAIT WATER FLOW TEMPERATURE < 80 C OPEN THE TIMER CONTACT WATER FLOW TEMPERATURE >80 C DO BURNER AND FAN SWITCH OFF CONTROL BOARD C.H. NTC OK WAIT 30 SECS. CONTROL BOARD DO PUMP SWITCH OFF C.H. NTC END CONTROL BOARD 30
33 SECTION 8 WIRING DIAGRAMS 8.1 EXTERNAL WIRING The appliance comes with a factory fitted clock to allow basic operation of the boiler (fig. 38). If external controls are to be added to the system, they must be connected to the appliance as shown in the following diagrams. For advice on controls that are not featured in this book, please contact the Service & Technical Helpline on factory configuration 8.3 ROOM THERMOSTAT Should a room thermostat be required, it must be of the voltage-free type, and should be connected to the appliance as shown in fig OTHER CONTROLS Contact the controls manufacturer and/or the technical help line should you require more specific information on the suitability of a particular control. Further guidance on the recommended practice for the installation of external controls, can be found in CHeSS - HC5/HC6 ( Fig TYPICAL CONTROL APPLICATIONS The appliance can be used with the following controls: external single-channel, voltage-free time clocks programmable room thermostats. In addition, the appliance can be used in conjunction with a typical S -Plan system, please contact the technical help line for further detailed instruction. TE This appliance is not suitable for use with Y -Plan systems. Fig
34 FUNCTIONAL DIAGRAM TE: L-N-E CONNECTION ADVABLE Key D.H.W.F.S. Domestic hot water flow switch P.S. Pressure switch P.D.S. Differential pressure switch H.L.T. High limit thermostat H.T. Heat thermistor D.H.W.T. Domestic hot water thermistor C.P.S. Condense pressure switch MOD Modulator F Fan P Pump 3 W 3 way motor OPE Gas valve solenoids JP1 C.H. only selector JP2 Setting timer JP3 Natural gas or L.P.G. selector JP4 Jumper disable/enable DHW absolut thermostat P1 Domestic hot water temperature control P2 Central heating temperature control P3 Off/summer/winter/combustion test P4 Minimum heating regulation P5 Heating potentiometer (must be set to max) F1-F2 Fuse 2 AF S.S.E. Spark\Sense electrode CP04X Control board CN1-CN9 Connectors RL1 Pump relay RL2 Fan relay RL3 Diverter valve motor relay RL4 Ignition relay TRF1 Trasformer TRX Ignition trasformer ACF01X Ignition control board M3-M6 External connections block LED Led OK (green) Led alarm (red) Combustion test (blink orange) Fig. 40 F2 = fuse 2AF 32
35 SECTION 9 EXPLODED DIAGRAMS POS. DESCRIPTION 25 HE 29 HE 1 Frame assembly Pressure gauge Cover assembly Printed Circuit Board Printed Circuit Board Led light guide Instrumental panel Control knob Selection knob Case Adapter Timer Fuse Edge clip Transformer Wiring harness (clock) Wiring harness (clock)
36 POS. DESCRIPTION 25 HE 29 HE 1 Domestic water heat exchanger Connection Pressure switch Non return valve By-pass casing By-pass valve Heating manifold and cartridge way valve cartridge Motorized valve Fixing fork wrench Fixing fork wrench Safety valve Flow governor Pipe DHW actuator Heating cock Connection Heating cock Pipe By-pass casing cover Discharge cock Pipe Pressure switch Washer Washer Washer Washer Clip Nut Nut Clip Clip Nipple Connection Clip O-Ring Washer Clip O-Ring O-Ring Washer NTC sensor (red O-Ring) Wiring harness (PCB + ground faston frame, ground faston floz switch pump diverter valve H20 pressure switch condense, pressure switch gas valve (modulator + safety coils) DHW NTC)
37 POS. DESCRIPTION 25 HE 29 HE 1 Expansion vessel Flexible pipe Circulation pump Automatic air vent bottle Pipe Pipe Heat exchanger Pipe Pipe Siphon Pipe Condensing unit assembly Pipe Pipe Flexible pipe Washer 24 x Washer 18,5 x Washer O-Ring Clip Connection O-Ring Clip O-Ring O-Ring Connections kit Limit thermostat NTC sensor (red O-Ring) Washer
38 POS. DESCRIPTION 25 HE 29 HE 1 Air box bottom Ambidx air box side Clip Burner assembly Spark electrode Burner plate Gas pipe Gas valve Gas pipe Gas cock Air box cover Washer Glass Flange Gas valve solenoid Washer Hole cap Washer N.G. conversion kit LPG conversion kit
39 POS. DESCRIPTION 25 HE 29 HE 1 Combustion chamber assembly Combustion chamber back panel Combustion chamber lateral panel Combustion chamber front panel Hood assembly Fan Venturi and pressure tube kit Clamp for tube Fan flue connection Block with combustion analysis check Brass cap Pressure differential switch Combustion - fan cable (PCB ground faston fan H 2 O limit thermostat CH NTC flue pressure switch)
40 SECTION 10 L.P.G. INSTRUCTIONS 10.1 RELATED DOCUMENTS BS 6798 INSTALLATION OF BOILERS OF RATED T EXCEEDING 60kW BS 5449 PART 1 FORCED CIRCULATION HOT WATER SYSTEMS BS 5546 INSTALLATION OF GAS HOT WATER SUPPLIES FOR DOMESTIC PURPOSES BS 5440 PART 1 FLUES BS 5482 PART 1 DOMESTIC BUTANE & PROPANE GAS BURNERS IN PERMAMENT DWELLINGS 10.2 TECHNICAL DATA GAS PRESSURES Inlet pressure 37 mbar 37 mbar 37 mbar Burner pressure maximum mbar mbar mbar Burner pressure minimum (heating) mbar mbar 7.00 mbar Burner pressure minimum (DHW) 4.90 mbar 4.50 mbar 3.20 mbar Maximum gas rate 1.94 Kg/h 2.25 Kg/h 2.70 Kg/h Minimum gas rate 1.16 Kg/h 1.16 Kg/h 1.16 Kg/h Injectot size (quantity) 12 x x x 0.76 SEDBUK (%) 87.7 Band B 87.9 Band B 87.7 Band B x (max - min) PPM CO (max - min) PPM CO 2 (%) CO/CO 2 ratio (max - min) to to to to to to CONVERTING THE APPLIANCE GAS TYPE To convert the appliance to another gas type it is necessary to change the burner injectors and adjust the gas pressures. It is also necessary to ensure the jumper tag at JP3 is enabled or disabled according to the gas type used. To change the injectors see section 6. For correct jumper tag configuration see GAS SUPPLY The gas supply must be connected to the appliance by a competent LPG installer and must be of sufficient size to supply the appliance at its maximum output. An existing supply must be checked to ensure that it is of adequate size to deal with the maximum rated input of this and any other appliances that it serves GAS SUPPLY INSTALLATION The entire installation including the meter must be purged and checked for gas soundness SETTING THE MINIMUM BURNER PRESSURE fig. 34 Once the maximum burner pressure has been checked and/or adjusted, remove one of the grey wires from the modulating coil. Compare the reading on the manometer with the value described in If adjustment is required, turn the inner (red) crosshead screw clockwise to increase, or counter-clockwise to decrease the burner pressure, whilst ensuring that the outer (10mm) nut does not move. When checking and/or adjustment and/or adjustment has been completed, isolate the appliance from the electrical supply, close the DHW outlet, replace the protective cap, refit the grey wire to the modulating coil, remove the manometer, and tighten the outlet test point. IMPORTANT, A GAS SOUNDNESS CHECK MUST BE CARRIED OUT CHECKING AND ADJUSTING BURNER PRES- SURE (see fig. 22) Isolate the appliance from the electrical supply and attach a suitable manometer to the gas valve outlet test point SETTING THE MAXIMUM BURNER PRES- SURE fig. 35 Light the boiler as described in 5.7, fully open a DHW outlet (preferably the bath) and ensure the HW temperature selector is set at maximum. Allow the appliance to stabilise. Compare the reading on the manometer with the value described in If adjustment is required, remove the protective cap from the gas valve modulating coil assembly and turn the outer (10mm) nut clockwise to increase, or counterclockwise to decrease the burner pressure. 38
41 BENCHMARK No. COLLECTIVE MARK GAS BOILER COMMSIONING CHECKLT BOILER SERIAL No. TIFICATION No. CONTROLS To comply with the Building Regulations, each section must have a tick in one or other of the boxes TIME & TEMPERATURE CONTROL TO HEATING ROOM T/STAT & PROGRAMMER/TIMER PROGRAMMABLE ROOMSTAT TIME & TEMPERATURE CONTROL TO HOT WATER CYLINDER T/STAT & PROGRAMMER/TIMER COMBI BOILER HEATING ZONE VALVES FITTED T REQUIRED HOT WATER ZONE VALVES FITTED T REQUIRED THERMOSTATIC RADIATOR VALVES FITTED AUTOMATIC BYPASS TO SYSTEM FITTED T REQUIRED FOR ALL BOILERS CONFIRM THE FOLLOWING THE SYSTEM HAS BEEN FLUSHED IN ACCORDANCE WITH THE BOILER MANUFACTURER S INSTRUCTIONS? THE SYSTEM CLEANER USED THE INHIBITOR USED FOR THE CENTRAL HEATING MODE, MEASURE & RECORD GAS RATE 3 /hr 3 /hr BURNER OPERATING PRESSURE (IF APPLICABLE) CENTRAL HEATING FLOW TEMPERATURE N/A C CENTRAL HEATING RETURN TEMPERATURE C FOR COMBINATION BOILERS ONLY HAS A WATER SCALE REDUCER BEEN FITTED? WHAT TYPE OF SCALE REDUCER HAS BEEN FITTED? FOR THE DOMESTIC HOT WATER MODE, MEASURE & RECORD GAS RATE 3 /hr 3 /hr MAXIMUM BURNER OPERATING PRESSURE (IF APPLICABLE) N/A mbar COLD WATER INLET TEMPERATURE C HOT WATER OUTLET TEMPERATURE C WATER FLOW RATE lts/min FOR CONDENSING BOILERS ONLY CONFIRM THE FOLLOWING THE CONDENSATE DRAIN HAS BEEN INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS? FOR ALL INSTALLATIONS CONFIRM THE FOLLOWING THE HEATING AND HOT WATER SYSTEM COMPLIES WITH CURRENT BUILDING REGULATIONS THE APPLIANCE AND ASSOCIATED EQUIPMENT HAS BEEN INSTALLED AND COMMSIONED IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS IF REQUIRED BY THE MANUFACTURER, HAVE YOU RECORDED A CO/CO2 RATIO READING? N/A CO/CO2 RATIO THE OPERATION OF THE APPLIANCE AND SYSTEM CONTROLS HAVE BEEN DEMONSTRATED TO THE CUSTOMER THE MANUFACTURER S LITERATURE HAS BEEN LEFT WITH THE CUSTOMER COMMSIONING ENG S NAME PRINT SIGN CORGI ID No. DATE 39
42 SERVICE INTERVAL RECORD It is recommended that your heating system is serviced regularly and that you complete the appropriate Service Interval Record Below. Service Provider. Before completing the appropriate Service Interval Record below, please ensure you have carried out the service as described in the boiler manufacturer s instructions. Always use the manufacturer s specified spare part when replacing all controls SERVICE 1 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SERVICE 2 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SIGNATURE SERVICE 3 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SERVICE 4 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SIGNATURE SERVICE 5 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SERVICE 6 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SIGNATURE SERVICE 7 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SERVICE 8 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SIGNATURE SERVICE 9 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SERVICE 10 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SIGNATURE 40
43
44 Cod Ed. 2 Heating Services provides after-sales assistance and Technical advice for Sabre Boilers Service & Technical Helpline: We reserve the right to change the specifications without prior notice. Consumers statutory rights are not affected COLLECTIVE MARK
AquaNova. Water heater. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER
AquaNova Water heater Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation
Mynute 25 A. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER
Mynute 25 A High efficiency system boiler Users Instructions Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims
Verve. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER
Verve High efficiency system boiler Users Instructions Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to
Excel. High efficiency combi boiler. Users Instructions. Installation & Servicing Instructions. Excel 25 G.C. N 47-364-12 Excel 29 G.C.
Excel High efficiency combi boiler Users Instructions Installation & Servicing Instructions Excel 25 G.C. N 47-364-12 Excel 29 G.C. N 47-364-13 THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed
Alpha CD13R,18R and 24R
Installation and Servicing Instructions Alpha CD3R,8R and 24R Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Regular Boiler Range For Technical help or for Service call...
Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler
Installation and Servicing Instructions Eco Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler For Technical help or for Service call... ALPHA HELPLINE Tel:
Mikrofill Ethos Condensing combination boiler
Mikrofill Ethos Condensing combination boiler Installation Instructions 24cc CE Mark No: 0201055 British Gas Service Listing G.C.No: 47-157-01 Mikrofill gas appliances comply with the requirements contained
ferroli Boiler Replacement Optimax HE- Modena HE
ferroli Boiler Replacement Optimax HE- Modena HE Introduction The new Ferroli Modena 32C HE high efficiency condensing combination boiler is an ideal replacement for the Ferroli Optimax HE 31 C and the
MULTIPOINT BF Gas Fired Balanced Flue Water Heater
Please leave these instructions with the user MULTIPOINT BF Gas Fired Balanced Flue Water Heater User Operating, Installation and Servicing Instructions 6 720 607 090 GB (04.10) JS Natural Gas Main Multipoint
Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers
Installation and Servicing Instructions Alpha 240/280 Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers For Technical help or for Service call... ALPHA HELPLINE Tel: 0870
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
Alpha InTec 12S, 18S, 28S
Installation and Servicing Instructions Alpha InTec 2S, 8S, 28S Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing System Boilers For Technical help or for Service
Installation & Servicing Instructions
The Range Linea 24 Linea 28 Installation & Servicing Instructions British Gas Service Listed G.C. No. 47 094 27 (Linea 24) G.C. No. 47 094 28 (Linea 28) G.C. No. 47 094 29 (Linea Plus) THESE INSTRUCTIONS
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Installation and Servicing Instructions
Installation and Servicing Instructions Alpha Pro Tec 50, 70, 90 and 5 Wall Mounted, Fan Assisted, Gas Fired, High Efficiency Condensing System Boilers For Technical help or for Service call... ALPHA HELPLINE
Alpha InTec 30GS and 40GS
Installation and Servicing Instructions Alpha InTec 30GS and 40GS Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers with a Passive Flue Gas Heat Recovery
Baxi Combi 80e & 105e
Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009
Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25
Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler
User s Operating Instructions Baxi Combi Instant 8e & 15e Gas Fired Wall Mounted Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
GREENSTAR 60/100 HORIZONTAL FLUE
FLUE KIT INSTALLATION MANUAL 7 76 9 08 ROOM SEALED TELESCOPIC FLUE 7 76 9 7 ROOM SEALED LONGER TELESCOPIC FLUE 7 76 9 086 PLUME MANAGEMENT SYSTEM GREENSTAR 60/00 HORIZONTAL FLUE FOR WORCESTER GREENSTAR
Users Instructions 0694 51BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER
Users Instructions 0694 51BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER G.C. NUMBER SABRE 25 HE N 470 94 70 SABRE 29 HE N 470 94 71 SABRE 35 HE N 470 94 72 Contents Introduction Page Dear customer 2
SERVICE SERVICE COMPACT MANUAL. Mod. 3000 92X Mod. 3000 93X Mod. 3000 94X. Part 2
SERVICE COMPACT SERVICE 000 MANUAL Mod. 000 9X Mod. 000 9X Mod. 000 94X Part Forward This Service Handbook is intended to assist with servicing and fault-finding in Caravans and Motor Caravans equipped
Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
Operating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
Combi 30 HE. Installation & Service Instructions
Installation & Service Instructions Combi 30 HE Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd 2009 Natural Gas Main
Baxi Bahama 100 Gas Fired Wall Mounted Combination Boiler
Baxi Bahama 100 Gas Fired Wall Mounted Combination Boiler Installation and Servicing Instructions BAXI Page 2 Natural Gas Baxi Bahama 100 G.C.Nº 47 075 02 Baxi Limited is one of the leading manufacturers
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
Instructions for installation and servicing ecomax
For the installer Instructions for installation and servicing ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/2 E ecomax 68/2 E ecomax 622/2 E ecomax 635 E ecomax 824/2 E ecomax
HALSTEAD. Best db 30/40/50/60 HALSTEAD INSTALLATION & SERVICING INSTRUCTIONS FOR THE
INSTALLATION & SERVICING INSTRUCTIONS FOR THE HALSTEAD CAST IRON HALSTEAD Best db 0/40/50/60 WALL MOUNTED FAN ASSISTED BOILER B R I T I S H M A D E B O I L E R S Best 0 G. C. No. 4 50 Best 40 G. C. No.
GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER
GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance
HeatSource HS1800 Heater
HeatSource HS1800 Heater Vehical Installation & Operating Instructions Propex Heatsource Ltd Unit 5, Second Avenue Buisness Park, Milbrook, Southampton, SO15 OLP Tel: 023 8052 8555 Fax: 023 8052 8800 Website:
-- ---- I u SYSTEM BOILER. Central Heating Faned Flue system. Installation. System 40. System 60. heygfj& AA
-- ---- I u SYSTEM BOILER Central Heating Faned Flue system System 40 System 60 Installation Operating and instructions heygfj& v AA These instructions are suitable for the following boilers : Britony
San josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
INSTRUCTIONS FOR INSTALLATION AND SERVICING TURBOmax VUW 242/1 E. TURBOmax VUW 282/1 E
INSTRUCTIONS FOR INSTALLATION AND SERVICING TURBOmax VUW / E TURBOmax VUW 8/ E Wall hung room sealed fan assisted combination boilers HEATING, CONTROLS, HOT WATER. Page. Introduction. Boiler Specification.
Betacom. 24c G.C. No. 47-019-08. 30c G.C. No. 47-019-09. Installation and Servicing. High Efficiency Condensing Combination Boilers
bar 3 4 5 2 6 1 7 24 8 23 9 22 10 21 11 20 12 19 13 18 14 17 16 15 Betacom Installation and Servicing 24c G.C. No. 47-019-08 30c G.C. No. 47-019-09 High Efficiency Condensing Combination Boilers ON 30
1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
INSTALLATION & TECHNICAL MANUAL
The COMET Range of Boilers the ultimate solution for central heating INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: [email protected]
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS Applied Energy Products Limited, Morley Way, Peterborough, PE2 9JJ, UK Telephone: +44 (0) 844 372 7761 / Fax: +44 (0) 84 372 7762 Website:
Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.
Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1. Please read and understand these instructions before starting work. Please leave this leaflet
Spare Parts List M96A.24SM/B M96A.28SM/B
*16202390* 162.0239.0 REV5 14/04 2015 Spare Parts List M96A.24SM/B M96A.28SM/B Issue Table description Issue n. of pages Overall view 09/2008 1 C.h. return group and d.h.w. heat exchanger 09/2008 1 C.h.
Zenith Solar thermal 4.5m pump station Installation manual
Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance
Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB
Gas Fired Cookers Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB FOR USE IN GB & IE PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING YOUR AGA Consumer Protection As responsible
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.
CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT
Cooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R8202395-02EN - Edition 02-21/04/2005
CUENOD Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CELTIC RSc b R8202395-02EN - Edition 02-21/04/2005 Boilers Solar Panel 69214511 31 CELTIC
3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
Operating instructions
6300 9681 02/2006 GB For the user Operating instructions Logano GE315 Boiler for oil-/gas-fired pressure jet burners Please read thoroughly before use. Operating instructions Logano GE315 Dear Customer,
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
24CDi/28CDi/35CDi II RSF
Bosch Group 24CDi/28CDi/35CDi II RSF WALL MOUNTED COMBINATION BOILER FOR CENTRAL HEATING AND MAINS FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS 24CDi 28CDi 35CDi II GC NUMBER (N.G) 47
Laddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S
*1756202470* 17562.0247.0 REV3 06/09 2012 Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S Issue Table description Issue n. of pages Overall view 06/2009 1 C.h.
solaris 24PC 30PC Pre-Mix Condensing Combination Boiler
solaris 24PC 30PC Pre-Mix Condensing Combination Boiler Installation, Servicing & User Instructions Natural Gas Heatline Solaris 24PC/30PC Pre-mix Condensing Combination Boiler British Gas Service Listing
High Efficiency Boiler Range Technical Guide
High Efficiency Boiler Range Technical Guide Glow-worm Nottingham Road Belper Derbyshire DE56 1JT Head Office: 01773 824 639 Literature: 01773 596 105 After Sales Service: 01773 596 510 Technical Advice:
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler
You can rely on User Guide and Important Warranty Information Heatmax Combi HE Range Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over
Flue Installation. High Efficiency Condensing Boilers
Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION
1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
Description of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions & Important Warranty Information Baxi Platinum Combi HE Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house,
Response: The combi boiler. Response: The fit anywhere combi
Response: The combi boiler The Ideal Response is a wall mounted, fanned flue combination boiler which serves a home's central heating system and delivers hot water on demand. It has been designed to be
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
orlando OWNER S MANUAL
orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions & Important Warranty Information Duo-tec Combi HE A Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move
Unvented water heater
Unvented water heater Description of water heater 1)Hot water outlet 2)Temperature and pressure relief valve (30 litre only) 3)Cold water inlet 4)Control cover 5)Regulation knob 6)Heating neon 1 4 5 6
Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options
Flue Options Ace Finest Finest Gold Best 30/40/50/60 Best 80 Flue Options Flue Options Flue Options Flue Options B r i t i s h M a d e B o i l e r s Halstead have been manufacturing boilers in the UK since
Table of Contents. 1 List of Contents... 4 1.1 Contents included with ecomax pro boiler... 4
To be left with the user Instructions for Use, Installation and Servicing ecomax pro GB Wall hung condensing boilers for traditional open vented systems 18 E 28 E Table of Contents Page 1 List of Contents.......................................
Getting the best from your urn
444448538 Standard 444448539 Deluxe Getting the best from your urn Remove any plastic film from the urn before use. Any water in the urn is due to testing and is normal. The urn must be used on a flat
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html Installation / Operating Instructions GOOD.BEETER>BOSCH Water Wizard 600 Continuous Flow Gas
Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions
Part No. 130009 Iss. 12 August 2004 Elson www.elsonhotwater.co.uk Open Vented Thermal Store providing mains pressure hot water heated by electricity Installation, Servicing and User's Instructions Read
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: This booklet should be left with the user after installation and demonstration Thank you for choosing a quality Redring product
Shower Handbook (Also covers 650 chrome variant)
Shower Handbook (Also covers 650 chrome variant) IMPORTANT: Please retain this booklet for future reference CONTENTS Page How to use your shower 2 How your shower works 3 What to do if things go wrong
Volkswagen Golf 5 2004-> VW Rabbit GTI 2006->
Стр. 1 из 24 Volkswagen Golf 5 2004-> VW Rabbit GTI 2006-> 19-1 Cooling system components Warning! Hot steam may escape when opening expansion tank. Wear protective goggles and protective clothing to prevent
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1
Visage Digital Digital diverter TM Installation guide Visage Digital diverter installation instructions Page 1 Visage Digital diverter Visage Digital concealed with adjustable and fixed head Visage Digital
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS
1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding with the installation,
Coolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500
Release R.2.0 Uk 80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500 Installation User and Service Manual www.state-waterheaters.co.uk your installer Warning Read this manual carefully before first
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board. This Troubleshooting Guide covers the electric coolant valve and control
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
MODEL 300505 INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping.
Unvented water heater
Unvented water heater 62 This product confirms to EU Directive 2002/96/EC. The symbol of the crossed waste paper basket on the appliance indicates that at the end of its working life the product should
Installation and Service Manual. Duo-tec Combi 24-28 - 33-40 28 LPG. Gas Fired Wall Mounted Condensing Combination Boiler
United Kingdom en Installation and Service Manual Gas Fired Wall Mounted Condensing Combination Boiler Duo-tec Combi 24-28 - 33-40 28 LPG These instructions include the Benchmark Commissioning Checklist