SK401-E. Stand-Alone Keypad & Proximity Card Reader. User Manual. External
|
|
|
- Scott Watkins
- 9 years ago
- Views:
Transcription
1 SK401-E External Stand-Alone Keypad & Proximity Card Reader User Manual
2 INTRODUCTION The SK401-E is a two relay multifunction standalone access control keypad suitable for either indoor or outdoor use. It is housed in a strong, sturdy and vandal resistant Zinc Alloy electroplated case. The electronics are fully potted making it extremely weather resistant and conforming to IP66 It supports up to 1100 users in a Card, PIN, or a Card + PIN option. The inbuilt card reader supports 125KHZ EM frequency card or key fob, and the Pin length is 4-6 digits Both relays can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines.etc) The SK401-E has many extra features including block enrollment, anti-tamper alarm & backlit keypad buttons These features make the SK401-E an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons Features Weather resistant to IP66 Strong Zinc Alloy Electroplated anti-vandal case Vandal resistant Backlit Keypad buttons Two LED status display Two Programmable Relay Outputs Relay 1: Up to 1000 Pin & Card holders, Relay 2: Up to 100 Pin & Card holders Card Block enrollment Integrated Alarm Buzzer & Output Low power consumption (55mA) Anti-Tamper Alarm Latch Mode/Toggle Mode Relay 2 Can Support Door Bell Feature 12-28V DC/12-18V AC Power Input (Cards/fobs will not work on AC power) 850mm cable tail
3 Specifications: User Capacity 1100 Cards/PINS Relay Relay Operating Voltage 12-28V DC / 12-18V AC Idle Current 55mA Active Current 80mA Keypad 12 Key (2*6) Proximity Card Reader EM Radio Technology 125KHz Industry Standard Proximity Card Read Range 20mm 35mm Wiring Connections Electric Lock, Exit Button, DOTL, External Alarm, Door Bell Relay Two (NO, NC, COM) Adjustable Relay Output Time 1-99 Seconds (5 seconds default) Adjustable Alarm Output Time 1-3 minutes (1 minute default) Lock Output Load 3 Amp Maximum Alarm Output Load 3 Amp Maximum Environment IP66 Operating Temperature , or -22 F F Operating Humidity 10% - 90% Non-Condensing Physical Zinc-Alloy Enclosure Surface Finish Powder Coat Dimensions H:129 x W:55 x D:22 (mm) Unit Weight 470g Package contents SK401-E Keypad Diode IN4004 (For relay circuit protection) Self Tapping Screws Wall Anchors Screw Driver &
4 INSTALLATION Remove the back cover from the unit Drill 2 holes (A,C) on the wall for the screws and one hole for the cable Knock the supplied rubber bungs to the screw holes (A,C) Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole (B) Attach the unit to the back cover Wiring cable Wire Insulation Colour Function Notes Red AC & DC 12-28V DC / 12-18V AC Regulated Power Input Black AC & DC 12-28V DC / 12-18V AC Regulated Power Input Grey & Black GND Negative Pole Blue NO1 Normally Open Relay 1 output White COM1 Common Connection for Relay 1 Output Green NC1 Normally Closed Relay 1 Output Yellow OPEN1 Request to Exit input 1 Advanced Input and Output Features Relay 2 Blue & Black NO2 Normally Open Relay 2 Output White & Black COM2 Common Connection for Relay 2 Output Green & Black NC2 Normally Closed Relay 2 Output Yellow & Black OPEN2 Request to Exit input 2 Grey Alarm - Alarm Negative Brown D_IN Door Status Detecting
5 Connection Diagram Examples Common power supply for magnetic lock (Fail open power to lock) Common power supply for lock release (Fail secure power to unlock) Common power supply for auto gate controller (using Normally Open contact) Comments: Relay 2 can be used to operate a doorbell if there is no need to operate a second door. The wiring to connect the doorbell is via NO2 and COM2. Press #, the SK401-E will send out a switching signal to the doorbell, as long as you press the #, the doorbell will operate, it will stop when you release the #
6 Function Description Relay operation (Pulse mode and Toggle mode) Both relays can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines.etc) Every time a valid card/fob is presented or a Pin input is made in Pulse Mode, the relay will operate, for the pre-set relay pulse time Every time a valid card/fob is presented or a Pin input is made in Toggle Mode, the relay changes state, which will not revert until a valid card/fob is re-presented or a Pin input is re-made Master Card The SK401-E can use Master Cards to program user cards/fobs into and out of the system. There are two pre-programmed Master Cards (an Add Card, and a Delete Card) to allow rapid card enrollment. They are for Relay 1 only Anti Tamper Alarm The SK401-E uses an LDR (light Dependent Resistor) as an anti tamper alarm. If the keypad facia is removed, the tamper alarm will operate PROGRAMMING Configure the Keypad Change the configure settings according to your application (optional). Multiple configuration settings can be changed at one time: Enter program mode, change the desired settings, then exit program mode Set Master Code The 4-6 digit Master Code is used to prevent unauthorized access to the system. To interface with the SK401-E, the administrator will need a Master Code (Factory default code: ). We recommend immediate update and recording of your Master Code Programming Step Keystroke Combination 1. Enter Program Mode *(Master Code) # 2. Update Master Code 0(New Master Code)#(Repeat New Master Code)# 3. Exit Program Mode *
7 SET ACCESS CONFIGURATION Card or PIN (Default): The User must present a valid card/fob to the SK401-E or enter their PIN code followed by the # key, in order to be granted access Card + PIN: The User must first present a valid card/fob to the SK401-E and then enter their PIN code followed by the # key, in order to be granted access Programming Step Keystroke Combination 1. Enter Program Mode *(Master Code) # 2. Card or PIN (Default) Relay # Relay # 3. Card + PIN Relay # Relay # 4. Exit Program Mode * User Settings To enter the programming mode * Master code # To exit from the programming mode * Note that to undertake the following programming, the Master PIN must be entered Note: When adding users, if the card/fob or Pin user has been enrolled already, you cannot add it again on the same relay, or the device will give a bleep as an error. It is ok to enroll the same card/fob or PIN for both relay outputs Factory default setting: Card or PIN mode To set users for Relay # To add PIN users 1 User ID number # PIN # The ID number is any number from The PIN is any 4-6 digits between with the exception of 1234 which is reserved. Users can be added continuously without exiting programming mode as follows: 1 User ID no 1 # PIN # User ID no 2 # PIN # To delete PIN users 3 User ID number # Users can be deleted continuously without exiting programming mode To change the PIN of a PIN user * ID number # Old PIN # New PIN # Repeat new PIN # (Note: This step must be done out of programming mode)
8 To add Card Users. (Method 1) This is an easy way to enter cards with auto-generated ID numbers The ID number will start from 1 if no user has been programmed To add Card Users. (Method 2) This is the alternative way to enter cards using User ID Allocation. In this method a User ID is allocated to a card. Only one user ID can be allocated to a single card To add a series of cards users Block Enrolment The card number must be consecutive 1 Read card # Cards can be added continuously without exiting programming mode 1 ID number # Card # The ID number can be any number from ID number # 8 digits or 10 digits Card number # Card quantity # Card quantity is between (This operation is only for relay 1) To delete Card users by cards Note: Users can be deleted continuously without exiting programming mode To delete Card users by user ID This option can be used when a user has lost their card To delete card users by card number 3 Read Card # The device can automatically identify the card of relay 1 or relay 2 3 Enter the User ID # 9 Input 8 digits or 10 digits Card number # Cards can be deleted continuously without exiting from programming mode To set users for Relay # To set Pin user for relay 2 is the same as relay 1, accept the ID number is for relay 2 To set Card user for relay 2 is the same as relay 1, with the exception of adding Card users with auto-generated ID numbers and Block enrolment as below To add Card Users. (Method 1) Auto-generated ID numbers 2 Read Card # Card can be added continuously without exiting programming mode
9 Card and PIN Mode To set users for relay # To Add a card and Pin user (The PIN is any four-six digits between 0000 & with the exception of 1234 which is reserved.) To change a PIN in card and PIN mode (Method 1) Note that this is done outside programming mode so the user can undertake this themselves To change a PIN in card and PIN mode (Method 2) Add the card as for a card user Press * to exit from the programming mode Then allocate the card a PIN as follows: * Read card 1234 # PIN # PIN # * Read Card Old PIN # New PIN # New PIN # * ID number # Old PIN # New PIN # New PIN # Note that this is done outside programming mode so the user can undertake this themselves To delete a Card and PIN user just delete the card 3 Read Card # or 3 User ID # To set users for relay # The operation is the same as relay 1 To set Card user only. (in this mode, users can only be valid by card or fob) To set Card user only # Relay # Relay 2 Entry is by Card/fob only Relay Setting (Pulse mode, Toggle mode) Pulse mode (Factory default) Pulse mode - Door relay time setting For Relay 1: # For Relay 2: # The door relay time is between 1-99 seconds, the factory default setting is 5 seconds. 1 means relay 1, 2 means relay 2 Toggle mode Toggle mode For Relay 1: # For Relay 2: #
10 Door, Alarm, Acoustic Signal, Door Bell Settings Door Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the internal buzzer will bleep automatically to remind people to close the door and continue for 1 minute before switching off automatically Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is forced open, the internal buzzer and alarm output will both operate To disable door open detection 6 0 # (Default) To enable door open detection 6 1 # It is optional to connect the D_IN line to LOCK1 or LOCK 2 Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes, depending on the option selected below Normal status: No keypad lockout or alarm 7 0 # (Default) Keypad Lockout 7 1 # Alarm Output 7 2 # Alarm output time To set the alarm output time # (Default is 1 minute) (1-3 minutes available) Acoustic Signal The acoustic signal can be set on or off. When on, the keypad will bleep when the key buttons are pressed, when off, the keypad will be in silent Normal status: On 8 6 # (Default) Acoustic signal Off 8 7 # Change Relay 2 to Door Bell (When there is no need to operate a second door, relay 2 can be set to operate as a door bell. The wiring is connecting the door bell to COM2 and NO2. Press #, and the keypad will send the signal to the door bell Relay # (Default) Door bell 8 9 # To remove The Alarm To reset the Door Forced Open warning To reset the Door Open Too Long warning Read valid card or Master Code # Close the door or Read valid card or Master Code #
11 Others Using Master Cards Using Master Card (It is only available for relay 1) Add a User Card Delete a User Card 1. (Read Master Add Card) 2. (Read User Card) Repeat Step 2 for additional user cards 3. (Read Master Add Card) 1. (Read Master Delete Card) 2. (Read User Card) Repeat Step 2 for additional user cards 3. (Read Master Delete Card) Reset to Factory Default: This will reset the SK401-E to the factory default but all card/pin information will still be retained This will also require reprogramming of the Master Add and Delete Cards NOTE: This is also useful if the original Master Add and Delete Cards have been lost 1. Power down the SK401-E 2. Press the * (Star) button and hold, at the same time power up the keypad 3. Release the button until both LED s shine (Parts 4 & 5 must be undertaken within 10 seconds) 4. Present any 125KHz proximity EM card or the Master Add Card (provided) to the SK401-E. This card is now the Master Add Card 5. Present any 125KHz proximity EM card or the Master Delete Card (provided) to the SK401-E. This card is now the Master Delete Card Erase all Users ** This will delete ALL User data for relay 1 or relay 2 as per below 1. Enter Program Mode: *(Master Code)# 2. Enter 30000# (for relay 1) Or # (for relay 2) 3. Exit: * **All configuration data is retained
12 SK401-E - Simplified Instruction Function Description Operation Enter the Programming Mode * (Master Code) # ( is the default factory master code) Change the Master Code 0(New Master Code)#(Repeat New Master Code)# (code: 4-6 digits) Add Card User 1 (Read Card) # ( for relay 1) 2 (Read Card) # ( for relay 2) Add PIN User 1 (User ID ) # (PIN)# ( for relay 1) 1 (User ID ) # (PIN)# ( for relay 2) The PIN is any 4-6 digits between Delete User 3 (Read Card) # 3 (User ID) # Exit * How to be granted access Card User Present card/fob PIN User Enter (PIN) #
P10 - Standalone Access Controller and Reader
www.quantek.co.uk T: 01246 417113 P10 - Standalone Access Controller and Reader 1 Description & Features: P10 is a waterproof standalone access control, reading EM&HID card, it uses advanced Microprocessor,
User Manual. Before installation and use, please read the user manual carefully.
Sebury Technology Co., Ltd. Address: 5/F, Building 8, Xinwu Industrial Park, Xili, Nanshan District, Shenzhen, China. Tel: +86-755-88856 Fax: +86-755-888565 P.C.: 58055 www.sebury.com.cn User Manual Before
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)
KCIENSBP KCIEN Heavy Duty Stainless Steel Illuminated Keypads Range: DIGICODE (Stand-Alone Keypad) INSTALLATION MANUAL Features: Input voltage: 12V to 24V AC or 12V to 48V DC Illuminated keys Heavy duty
PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00
Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 [email protected] www.satel.eu WARNINGS Read carefully
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
PAC1 Door Access Controller
PAC1 Door Access Controller Series 2 IMPORTANT DIFFERENCES FROM SERIES 1 1. A PACDL data logger revision 4.0 or higher attached to the DLOG terminal is able to program all features (i.e. times, relay type,
Secure Keypads for access control
torm Secure Keypads for access control Strike Master Read this manual carefully before attempting to install, program or operate the STORM AXS Strike Master Keypad. After installation the Command Summary
PROXIMITY CARD READERS C-10, C-20, C60, C70
Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0 CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection
INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK
Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: [email protected] INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP
GSM Autodialer Professional GJD700 Speech & Text Autodialer
Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred
SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals
SSW-iLM Keypad Note: This product is designed to be installed and serviced by security and lock industry professionals Specifications Case dimensions: 6 1/2 L x 1 3/4 W x 1 1/8 D Electrical: 5-12VDC Only
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
GV- RK1352 Card Reader
GV- RK1352 Card Reader The GV-RK1352 is a card reader with keypad, designed to recognize PIN codes, identification cards or both. Featured with the Wiegand and RS-485 outputs, the unit can be connected
INSTALLATION MANUAL XM3 Reader
INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access
CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
POINTS POSITION INDICATOR PPI4
POINTS POSITION INDICATOR PPI4 Advanced PPI with Adjustable Brightness & Simplified Wiring Monitors the brief positive operating voltage across points motors when they are switched Lights a corresponding
INSTALLATION GUIDE. www.security.soundstream.com FCC ID NOTICE
AL.1 AUTO SECURITY SYSTEM INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device
Operating Instructions. Keypad 2605..
Operating Instructions Keypad 605.. Contents Device description...4 Device presentation...5 Areas of application...6 Operation...8 Acknowledgement signals... 10 Start-up sequence... 11 Connection terminals...1
TS510 & TS500. Installation & User Guide. Compatible Equipment
Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction
GSM AD05 Slave GSM Auto Dialer- Instruction Manual
GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second
GV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-A
9452/9453 Installation and User Guide
9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and
GV-AS Controller. Installation Guide
GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASHV1124-A-EN 2011 GeoVision, Inc.
IEI 232e Standalone TM Keypad Installation/ Programming Manual
IEI 232e Standalone TM Keypad Installation/ Programming Manual Contents Section 1: Section 2: Section 3: Section 4: Section 5: Section 6: Section 7: Section 8: Section 9: Section 10: Features and Product
VARIO PROX CARD READER INSTALLATION MANUAL
VARIO PROX CARD READER INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION...2 1.1 Legend...3 1.2 Terminology...4 2.0 MOUNTING...5 3.0 WIEGAND CONNECTION...6 4.0 AUX BUTTON INPUT...7 5.0 INSTALLER PROGRAMMING...8
How To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK
3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: [email protected] INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK INTRODUCTION
INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.
SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection
SYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
AUTODIALLER / QUICKDIALLER - SA132
AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
Adaptability to Enhanced Security
Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
Adaptability to Enhanced Security
Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access
Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage
Description Supports DALI interface driver Programming Supports 0-10V Programmable Driver Programming Supports Other Controllers (TDD-ANPNx, SDD-AAPNx) Off-line programming capability Auto programming
BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS
BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS WG2 Dimensions: LxHXW: 26 x 14.5 x 29.5 cm INTERNAL Alarm Terminals EXTERNAL Alarm Terminals WG2 Control Unit WaterGuard
SECURITY SYSTEM ADP-CAN
INSTALLATION INSTRUCTION SECURITY SYSTEM ADP-CAN Introduction Motorcar security system ADP-CAN is for motorcars provided with CAN net. It is for the work with the motorcar factory security systems or remote
1R / 4-BUTTON SERIES
Button 1 1R / 4-BUTTON SERIES VEHICLE SECURITY SYSTEM Standard Features: Two 4-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren Dual stage impact detector Remote
AR-721U/721K/661U User s Guide
AR-72U/72K/66U User s Guide Feb. 6, 2004 Table of Contents Page. Main Feature --------------------------------- 3 2. AR-72U Installation --------------------------------- 4 2. Steps ---------------------------------
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal
O N DS160/DS161 Installation Guide High Performance Request-to-Exit Sensors 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for Request to Exit (REX) interior applications.
EQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access
Points Position Indicator (PPI1) for Points Motors with Common Ground
Points Position Indicator (PPI1) for Points Motors with Common Ground Monitors Points Action and Operates Leds on a Control Panel Monitors the brief positive operating voltage across points motors when
VEHICLE SECURITY SYSTEM G25/G20
VEHICLE SECURITY SYSTEM G25/G20 Limited Lifetime Warranty This vehicle security system is warranted to the original purchaser, to be free from defects in material and workmanship. The manufacturer will
1 x TS0861 Magnetic Swipe Card Reader. 1 x Installation Guide (this document).
g GE Interlogix TS0861 Magnetic Swipe Card Reader Installation Guide Installation Kit 1 x TS0861 Magnetic Swipe Card Reader. 1 x Installation Guide (this document). 2 x 3x6mm post button head screws that
Combi B Alarm box. Mounting instructions
Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
Installation manual. Version 1.1. www.videx-security.com
Installation manual Version 1.1 www.videx-security.com 2 Table of Contents MANUAL INTRODUCTION... 4 SYSTEM INTRODUCTION... 4 SYSTEM COMPONENTS... 5 CONTROLS... 6 3.5A 13.8Vdc PSU... 6 CONTROL PCB... 6
User s Information Guide R1A
HSC505-R Home Security Controller - User Manual Release R1a Pi HSC505 and Pi HSC505R Home Security Controller User s Information Guide R1A Page 1 QD Dynamics (Pty) Ltd reserves the right to make changes
PK5500 v1.1 Installation Instructions
PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on
AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS
AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS 1 DORANI VIDEO INTERCOM - 2 WIRE SERIES 7 TFT MONITOR TECHNICAL SPECIFICATIONS 7 Colour TFT screen 480 x
RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4
RUST ELECTRONICS LTD Remote Switching Unit RCU-O4 MAINS REMOTE SWITCHING UNIT RCU-O4 The RCU-O4 is a radio remote controlled switching unit that will allow the remote operation of any appropriate electrical
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
SYSTEM 45. C R H Electronics Design
SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25
e-ask electronic Access Security Keyless-entry
e-ask electronic Access Security Keyless-entry e-fob Keyless-entry entry System Full-Function Function Installation Manual FCC ID: TV2EFOB1 (UM20 ~ 22793-02) Table of Contents Introduction... 1 e-fob Operation
Shunt lock function 3066
Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning
AYC-FGx4 Family. Instruction Manual. Backlit, Waterproof Convertible Reader / Controllers. Models: AYC-F54 AYC-F64 AYC-G54 AYC-G64
AYC-FGx4 Family Backlit, Waterproof Convertible Reader / Controllers Instruction Manual Models: AYC-F54 AYC-F64 AYC-G54 AYC-G64 August 2010 Table of Contents Table of Contents 1. General Information...
SYSTEM 7000 IRIS+ USER MANUAL
SYSTEM 7000 IRIS+ USER MANUAL Table of Contents Section Page No 1. INTRODUCTION... 3 2. THE DISPLAY... 3 3. TRANSMITTERS... 6 4. MESSAGE PAGER SYSTEM... 7 2 1. Introduction 1.1 The IRIS+ is a radio based
ACCESS CONTROL SYSTEM
ACCESS CONTROL SYSTEM Flexible, Expandable, Economical. The i-pass system comprises of the i-pass controller built with state of the art technology to provide reader access for up to 16 doors and 32 elevator
Automatic Telephone Dialer TD-101(W)
Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages
LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution
GST301. (Single Protection Zone) Operation Manual
GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical
GERONIMO ANALOGUE HEAVY DUTY TELEPHONE
GERONIMO ANALOGUE HEAVY DUTY TELEPHONE Installation and Connection Instructions K a l i k a L t d., I n n o v a t i o n H o u s e, A l e x a n d e r B e l l C e n t r e, H o p k i n s o n Wa y, A n d o
ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system
pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
ADDING and/or DELETING PIN NUMBERS (Plus other simple programming commands) in My DK-16 or DK-26 DIGITAL KEYPAD
ADDING and/or DELETING PIN NUMBERS (Plus other simple programming commands) in My DK-16 or DK-26 DIGITAL KEYPAD A recurring call that we get here at Securitron Technical Support is from end users of our
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Installation Instructions
Installation Instructions For WiFi/LAN Video Intercom Manual Version 2 BFT Americas 6100 Broken Sound Parkway N.W. Suite 14, Boca Raton, FL 33487 www.bft-usa.com Toll Free: 877-995-8155 Office: 561-995-8155
Microprocessor Home Security System
numbers of sensor s activations in the zone and after which activations the zone will be discarded (ignored). On every system s arming the counter is cleared in self. 6.3.11. 2 - Triger Timer - enter a
How To Control A Car Alarm On A Car With A Remote Control System
MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock
Desktop Programmer (DTP)
INSTALLATION Desktop Programmer (DTP) Keypads & Readers Contents Set up the System...1 RCI DTP Contents...1 Install the System...2 Initialize the Program...2 Initialize the Door Locks...3 Add a User...4
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
ACTIVE 5 ENGINEERING MANUAL
ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features
IN-OUT Thermometer with Cable Free Sensor and Clock
IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Paxton Compact panel Mount Reader
68 It is common for a door entry telephone system to be combined with a proximity access system to allow easy access by residents, tenants or staff. Distributors have sourced products from two manufacturers
INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200
INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 FUSION CULTURE TABLE OF CONTENTS There s no point doing something if no one notices. We ve always believed the way to make things happen is by getting
CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual
SUPA8 Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS... 1 INSTALLATION OF THE SECURITY SYSTEM... 2 COMMISSIONING THE DIALLER PANEL... 5 ZONE INPUT CONNECTIONS... 7 PANEL
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
ELECTRONIC LOCKING SYSTEMS
ELECTRONIC LOCKING SYSTEMS Electronic Locking Systems Electronic locks for display cases, lockers and sliding doors This small intelligent electronic cabinet lock has a wide range of uses. Based on a
Kit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness
WIRING HARNESS FOR AS635P4 ANTENNA NOT USED 5 PIN WHITE PLUG 2 PIN WHITE PLUG GREEN - PARKING BRAKE INPUT (-) BLUE - NOT USED 3 PIN BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness
A C C E S S C O N T R O L S Y S T E M
A C C E S S C O N T R O L S Y S T E M TIME & ATTENDANCE SYSTEM Model No. Z.AC.R.BIO.M8.TA Z.AC.RC.BIRO.M8+ID.TA Type: BIOMETRIC TIME & ATTENDANCE SYSTEM Combination of silver & black colour Instant verification
Operating Instructions
D-TEK Vehicle Loop Detector Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product
INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS
3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS INSTALLATION MANUAL Before you begin the installation Read the INSTRUCTIONS! Always use a multi-meter when verifying vehicle wiring. Before mounting the
TOMAHAWK CAR ALARMS. TW-9010 Two Way Car Alarm System
TOMAHAWK TW-9010 TOMAHAWK CAR ALARMS TW-9010 Two Way Car Alarm System USER MANUAL INSTRUCTIONS FOR INSTALLATION TOMAHAWK TW-9010 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Fitting/Installation Guide - UNIVERSAL
ATTENTION: This wiring information is being provided free of charge and on an as is basis, without any representation or warranty. It is your responsibility to verify any circuit before interfacing with
INSTALLATION MANUAL PC2525. Version 1.1
INSTALLATION MANUAL PC2525 Version 1.1 TABLE OF CONTENTS FEATURES 1 SPECIFICATIONS 1 INSTALLATION 2 Mounting the Panel... 2 Mounting the Keypad... 2 Auxiliary Power Connection... 2 Bell/Siren Connection...
STAND-ALONE PROXIMITY ACCESS CONTROL SYSTEM
SOLO installation manual STAND-ALONE PROXIMITY ACCESS CONTROL SYSTEM Company Profile CENTURION SYSTEMS has been manufacturing automatic gate systems since 1987, and is committed to providing reliable,
BUSINESS COMMUNICATIONS DIVISION. IP4100 SIP DECT User Guide
BUSINESS COMMUNICATIONS DIVISION IP4100 SIP DECT User Guide TOSHIBA IP4100 DECT HANDSET END USER GUIDE FEATURES Toshiba IP4100 DECT Handset Features 2.0 inch colour TFT back-lit display Li-ion battery
Matrix 424/832/832+ ICON & LCD User Manual. Software Version 5 RINS915-2. EN50131-1 Security Grade 2 Environmental Class 2
Matrix 424/832/832+ ICON & LCD User Manual Software Version 5 RINS915-2 EN50131-1 Security Grade 2 Environmental Class 2 CONTENTS CHAPTER 1: INTRODUCTION... 1 CHAPTER 2: REPLACING THE BATTERIES... 2 CHAPTER
MANUAL Remote Programmer XM3
MANUAL Remote Programmer XM3 Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration
