User Manual. Before installation and use, please read the user manual carefully.

Size: px
Start display at page:

Download "User Manual. Before installation and use, please read the user manual carefully."

Transcription

1 Sebury Technology Co., Ltd. Address: 5/F, Building 8, Xinwu Industrial Park, Xili, Nanshan District, Shenzhen, China. Tel: Fax: P.C.: User Manual Before installation and use, please read the user manual carefully.

2 Contents. Description, Features and Specifications. Quick Installation Guide. Manager Card Operation. User Settings 5. Alarm 6. To Reset to Factory Default 7. Sound and Light Indication 8. Detailed Programming Guide 9. Advanced Application - Various Working Mode Application 9. Wiegand Reader 9. Standalone for Single Door 9. Automatic Mode 9. Standalone for Two Doors 9.5 With External Reader for Two Doors 9.6 Two Units Interlocked for Two Doors 9.7 Anti-passback for Single Door 9.8 Anti-passback for Two Doors 0. Simple Troubleshooting. Packing List

3 . Description, Features and Specifications. Specifications. Description The stouch-w / skey-w / stouch-s / skey-s include an access host and a i Box, which are connected by Wiegand Bus. The access host permits entry using proximity technology and keypad with PIN, and the i Box provides Power Supply, Lock Driver, Alarm, Ring Bell, Exit Button and Door Contact for the whole system. The access host supports 5KHz EM, HID cards and.56mhz (stouch-w / skey-w) Mifare, CPU cards all in one. It is with relays to control doors and supports up to 000 users in total, each user can possess one card and one PIN. Besides, it also supports Master Code, Manager Cards, Duress Card users and Duress PIN users, providing users with easy operations and safety reliability.. Features Strong pure aluminium alloy case; waterproof, conforms to IP65 Built-in switching power supply for i Box, input AC 00-0V or DC -V Split design of the control part, prevent opening the door by strong magnetic, short circuit, open circuit or other illegal ways Built-in 5KHz and.56mhz card reader (stouch-w / skey-w) Built-in 5KHz card reader (stouch-s / skey-s) Digital backlit key, the back light can be set to Normal ON, Normal OFF or Human-Approach ON Built-in door bell and also support external door bell function Multi working modes: reader, one door, two doors, interlock, anti-passback and so on, suitable for many occasions.. Access Host Input Voltage Idle Current Card Reading Distance Card Frequency Card Transmission Format Keypad Transmission Format Dimension Operating Temperature Operating Humidity.. i Box Input Controller Total Output Power Power Input Voltage Access Host Port Output Current 0 0 i Box DC V-V 5mA 0mm Max 5KHz &.56MHz(sTouch-w / skey-w) 5KHz (stouch-s / skey-s) 6-7 Bit Bit, 8 Bit and Virtual Card Number mm (s Touch-w / s Key-w) -0 C ~ 60 C 0%~95% AC 00V-0V 6W DC V-V 0.5A 6 97 mm Operating Temperature -0 C ~ 60 C Operating Humidity 0%-95% 58.7 mm (s Touch-s / s Key-s)

4 . Quick Installation Guide (Before installation and use, please read the Quick Installation Guide carefully) Logo Indicator Light Logo Indicator Light Bracket Touch Keypad Metal Button Keypad Infrared Receiving Hole Infrared Emission Hole Card Swiping Area Infrared Receiving Hole Infrared Emission Hole Card Swiping Area Photosensitive Tamper Window Sound Hole Safe Screw Hole Access Host Bottom Panel Door Bell Button Door Bell Button Connect Wire Access Host Front Panel Access Host Front Panel Access Host Back Panel 0 0

5 Sticker Size: 78 X mm Product Bracket Size : 7.8 X 5.9mm Diameter: 6mm(Rubber Bungs) Diameter: mm Diameter: 0mm mm Logo Indicator Light Touch Keypad Safe Screw Hole Drill Holes For concrete wall, drill the hole in 6mm diameter Fix the Bracket and Install the Access Host Infrared Receiving Hole Infrared Emission Hole Access Host Bottom Panel Card Swiping Area Door Bell Button Access Host Front Panel Bracket 5.9 mm 8.80 mm Logo Indicator Light Metal Button Keypad Infrared Receiving Hole Infrared Emission Hole Card Swiping Area Photosensitive Tamper Window Sound Hole Connect Wire Door Bell Button Access Host Front Panel Access Host Back Panel Pay attention to the sequence during installation 05 06

6 7mm Fix Safe Screws Install i Box and Exit Button Diameter: 6mm (Rubber Bungs) Install Lock Wiring AC00V~0V Yellow-Green Diameter: mm Blue N L Brown Short circuit plug for lock Lock (not included in the package, please equip it locally) +V GND D0 D OPEN GND NC +V Diameter: 6mm (Rubber Bungs) Red Black Green White Yellow Yellow Black N00 Red Diameter: mm mm Diameter: 7mm Access Host Exit Button Lock Safe Screws Before installing exit button, please read its user manual carefully Remark: > Pay attention to the sequence when wiring, for different types of locks, please refer to their user manual > For the indicator light of exit button, need to connect an extra V power supply 07 08

7 L N Input AC00-0V External DC Power Red Black Green White Access Host Door Bell Alarm Door Contact Exit Button Lock (A / B) Short-Circuit Wire ( Wiring ) Lock (A / B) +V +V LOCK A + + N00 LOCK B N00 NC NO NO NC COM GND COM GND Here are some lock wirings based on different locks: Lock Wiring Connecting COM and GND, then connecting lock to +V and NO (or NC) Lock Type A: Fail Secure Lock (Unlock when power on ), such as Electric Controlling Lock, etc. Lock Type B: Fail Safe Lock (Unlock when power off ), such as EM Lock, Electric Bolt Lock, etc. IN00: Diode, which is mainly used for preventing the harmness on relay from surge high voltage of Lock when relay contact is released. The use life of relay will be shortened and the high voltage pulse will affect other circuit BELL_A BELL_B Door Bell Interface Principle Relay contact in BELL_A & BELL_B will be close for 00mS then release for each bell stroke. +V +V ALARM- Alarm Interface Principle FET (field effect transistor) will be connected when alarm operates, and vise verse. +V +V NO NC COM GND Lock Interface Principle Relay will be picked up once unlocking instruction received, and it will be released when unlocking time is beyond. COM: Relay Contact NC: Normal Close, which is connected with COM normally. NO: Normal Open, which is disconnected with COM normally. N00 Lock A Short-Circuit Wire N00 K+ K- Lock A Short-Circuit Wire 09 0

8 N00 Short-Circuit Wire Lock B Lock B N00 Short-Circuit Wire. User Settings. To unlock the door by single card only: Read valid card once, the door will open. Precondition: > Set the door entry by card only > Set for opening the door by multi cards. To unlock the door by multi cards: Read -0 pcs valid cards (time interval can not exceed 5s), the door will open. Precondition: > Set the door entry by card only > Set -0 for opening the door by multi cards. To unlock the door for card and PIN users Read valid card Input -6 digits PIN #, the door will open. Manager Card Operation. To add card user by Manager Add Card (only for Zone ) Manager Add Card User Card Manager Add Card Cards can be added continuously. To delete card user by Manager Delete Card (for both Zone and Zone ) Manager Delete Card User Card Manager Delete Card Cards can be deleted continuously. To unlock the door for card or PIN users Read valid card Or Input -6 digits PIN #, the door will open.5 Relay operation Both of the two relays on board can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines etc) Pulse Mode Every time a valid card/tag read or PIN input in Pulse Mode, the relay will operate, for the pre-set relay pulse time. Toggle Mode Every time a valid card/tag read or PIN input in Toggle Mode, the relay changes state, which will not turn back until read card/tag or input PIN again.

9 .6 To change the PIN of a PIN user Read card Old PIN # New PIN # Repeat New PIN # Or User ID number Old PIN # New PIN # Repeat New PIN # Remark: st For users without card, must get ID number and initial PIN from the master. For Zone, the digit of PIN must be, st for Zone, the digit of PIN must be For the card users with PIN, must use reading card to change the PIN for the first time..7 Door Bell Press the door bell button on the access host, the buzzer will sound ring-back tone, at the same time, the smart controller's built-in door bell or the external door bell will ring. There are working modes optional: Mode 0 : Door bell function is unavailable. Mode : Access host's ring-back tone is available, i Box's built-in door bell is available, the external door bell is unavailable. Mode : Access host's ring-back tone is available, i Box's built-in door bell is unavailable, the external door bell is available. Mode : Access host's ring-back tone is available, i Box's built-in door bell is available, the external door bell is available. Remark: When the access host's working mode is Automatic Mode (Factory Default Mode), without the smart controller, there will be no ring-back tone. Automatic Mode: In this mode, when the access host connects to i Box, it is standalone for single door; If without smart controller, it work as Wiegand reader automatically. 5. Alarm 5. Anti Tamper Alarm When enable the anti tamper alarm function, if the access host is disassembled illegally, the access host's buzzer and the external alarm will operate. 5. Door Contact Alarm When connect with door contact, if the door is opened illegally, the access host's buzzer and the external alarm will operate. 5. Anti-duress Alarm When read Zone duress card / input 8-digit duress PIN or Zone duress card / input 8 -digit duress PIN, then press #, the corresponding lock will open, at the same time, the external alarm will operate, but the access host buzzer will not operate. 5. To Remove the Alarm Read valid card or input master code can remove the alarm. If there is no operation, the alarm will remove automatically after min. 6. To Reset to Factory Default To reset to factory default, power off, then power on, the logo will turn into orange after s, press * within s, release it until hear two beeps, then will hear one long beep and the logo turn in white, means reset to factory default successfully. Remark: Reset to factory default, the users' information is still retained.

10 7. Sound and Light Indication 8. Detailed Programming Guide Operation Status Standby Press Key Read Card Door Open Operation Successful Operation Failed PIN Inputting Card & PIN Reading Multi Card Reading Start Menu Sub Menu Under Setting Manager Card Ente r Manager Card Exit Alarm Ring-back Tone Logo Color White Green Green Green Red Red Red Slow Shine in White Red Orange Orange White Quick Shine in Red Buzzer Short Ring Long Ring Long Ring Long Ring Short Ring Short Ring Long Ring Alarm Ding-Dong Standby * Master code Start Menu 0 Sub Menu 0 Setting White Red White Flash Red Orange Master code # Master * code # Logo LED Light indication Administrator setting New master code # Repeat new master code # (Note: Code length:6~8 digits, factory default :888888) Read Manager Add Card Read Manager Delete Card Read duress card (Zone ) Read duress card (Zone ) Remarks st 8-digit duress PIN # (Zone ) (Note: The digit must be ) st 8-digit duress PIN # (Zone ) (Note: The digit must be ) 0000 # (Note: This is a dangerous option, so use with care) Read card User ID number # read card Card number # ID number # Card number # User Setting for Zone. The user ID number is any number among Card number must be 8 or 0 digits, if the card number is less than 8 or 0 digits, input 0 before the card number. Users can be added continuously without exiting programming mode Functions Change the master code Set Manager Add Card Set Manager Delete Card To set duress users (Note: There are only one duress card and one PIN available for each Zone. When input duress PIN/card, the door will open, at the same time, the external alarm operates.) Delete ALL users To add Card users 5 6

11 Master * code # 5 User ID number # PIN #. The user ID number is any number among st. The PIN is any -6 digits, digit must be To add PIN users with the exception of which is reserved. Users can be added continuously without exiting programming mode Add the card as for a card user Press * exit from the programming mode, then allocate the card a PIN as follows: * Read card # PIN# Repeat PIN # Card number # Read Card User ID number # Note: > Users can be deleted continuously without exiting programming mode > To delete Card and PIN users just delete the card To add Card and PIN users To delete Card users by card number To delete Card users by cards To delete Card or PIN users 0 # Entry is by Card ONLY To set valid Card users # Entry is by Card and PIN together To set valid Card and PIN users # Entry is by either Card or PIN To set valid Card or PIN (Factory default setting) users 0~99 # 0 = 50mS, factory default setting: 5 To set door relay time 0 # Every time a valid card/tag read or PIN input, the relay will operate, for the pre-set relay pulse time. (Factory default setting) Relay Setting- Pulse mode * * * Master code # Master code # Master code # 6 7 ~0 # User ID number # Card number # Card Quantity # Note: The door will open only when read the valid card quantity up to the quantity set. It is only for Card ONLY Mode (Factory default setting: ) The card number must be consecutive Card quantity is between -000 User Setting for Zone st The method is same as Zone, the only difference is the digit of PIN for Zone must be 0 Advanced Application (System setting) To set open door by multi cards To add a series cards users-block Enrollment 0~5# Factory default setting: 0 To set facility code 0# Wiegand reader # Standalone for single door # # # 5# 6# 9# Standalone for two doors With external reader for two doors Two units interlocked for two doors Anti-passback for single door Anti-passback for two doors Automatic mode ( Factory default setting) To set working mode 6~7 # Factory default setting: 6 To set Wiegand format 0~ # Note: When device reset to factory default, the setting is still valid To set keypad transmission format # Every time a valid card/tag read or PIN input, the relay changes state, which will not turn back until read card/tag or input PIN again Relay Setting-Toggle mode 7 8

12 * * Master code # Master code # 9 0 # # Optional Setting OFF- The device will be in silence except enter the programming mode ON-The device will give the voice when press the keys (Factory default setting ) 9. Advanced Application - Various Working Modes Application Access host can work in 8 modes as below.. Wiegand reader. Standalone for single door To set keypad tone ON or OFF 0 # No door bell function # Built-in door bell - ON(Factory default setting) To set door bell function # External door bell - ON 5 # 0 # # # 0 # # 0 # # Built-in & external door bell - ON Disable keypad backlight Enable keypad backlight(factory default setting) Automatic mode Normally it is off (sleeping mode) but wake up with human approach Disable Enable (Factory default setting) Disable anti tamper alarm (Factory default setting) Enable anti tamper alarm Administrator open the door To set keypad backlight To set logo LED light (Stand-by status) To set anti tamper alarm Administrator open door Administrator open door. Automatic mode (Factory default setting). Standalone for two doors 5. With external reader for two doors 6. Two units interlocked for two doors 7. Anti-passback for single door 8. Anti-passback for two doors 9. Wiegand Reader Mode Common Access Controller 9 0 +V Red GND D0 D LED BZ Black Green White Brown Yellow i Box Access Host (Other Modes) Access Host Access Host (Automatic Mode) (Wiegand Reader) Red Black Green White In this mode, the access host works as reader, it can be done below settings. > Change Master Code > Set Facility Code > Set the card transmission format > Set the keypad transmission format > Set optional setting > Anti-Tamper alarm When LED level is low, Logo light will turn into Green, after 0 seconds or LED level rising, Logo light will back to normal. When BZ level is low, the Buzzer will beep, after 0 seconds or BZ level rising, the Buzzer will back to normal. When the access host worked as reader, both card number and keypad transmits in Wiegand format, the output data are shown by the Low Level of D0 & D cable: D0: Low Level means 0, green cable D: Low Level means, white cable The Pulse Width of Low Level is 00uS, Bit period is.6ms -V Red GND D0 D Black Green White

13 The digit of card number can be set to 6~7Bit, should be matched with the controller. (Factory default is 6Bit) Keypad transmission can be set in the following modes (modes can be set by user) Model 0: Virtual card number The Reader will transmit the PIN data when it receives the last key (#) press after PIN code st th th th Format: Decimal card number with 0-digit, Facility Code ( ~ digit) + PIN Code ( 5 ~ 0 digit) (Facility code is any digits between 0~5, PIN code is ~6 digits) Example: Facility code: 5 PIN code: 999 Press 999 #, then output format will be: PIN code: Press #, then output format will be Standalone for Single Door The wiring diagram is shown as below. In this mode, the access host uses for entering the door, it supports connecting external card reader for exiting door. The users of Zone of access host or external card reader can open the door by valid card or PIN. Zone is invalid. Model : -Bit The output data is provided in following format after every key is pressed: Model : 8-Bit The output data is transmitted in following format after every key is pressed: Key Output in hex Output in Binary A # B 0 Key Output in hex Output in Binary A # B 0000 L N Input AC00-0V Inside Door Outside Door Red Black Green White Access Host (Enter Door) Door Bell Alarm Door Contact Exit Button N00 N00 Lock (A / B) Short-Circuit Wire 5 6

14 9. Automatic Mode In this mode, when the access host connects to i Box, it is standalone for single door; If without smart controller, it work as Wiegand reader automatically. 9. Standalone for Two Doors In this mode, stouch-w/skey-w / stouch-s / skey-s users are for controlling two doors. Read valid card or input PIN of Zone on access host, door will open; read valid card or input PIN of Zone on access host, door will open. Remark: The common card for Zone and Zone can only open door. 9.5 With External Reader for Two Doors In this mode, access host is for entering door, and external reader is for entering door. Read valid card or input PIN of Zone on access host, door will open; read valid card or input PIN of Zone on external reader, door will open. Remark: The common card for Zone and Zone can open door on access host, and open door on external reader. N00 N00 N00 N00 L N Input AC00-0V Inside Door Access Host ( Enter Door or Door ) Red Black Green White Door Bell Alarm Door Contact Exit Button Lock (A / B) Short-Circuit Wire L N Input AC00-0V Access Host (Enter Door ) Red Black Green White Inside Door Door Bell Alarm Door Contact Exit Button Lock (A / B) Short-Circuit Wire Outside Door Door Contact Exit Button N00 N00 Lock (A / B) Outside Door External Reader(Enter Door ) Red Black Green White Door Contact Exit Button N00 N00 Lock (A / B)

15 9.6 Two Units Interlocked for Two Doors The interlocked function is mainly used in banks, prisons, and other places where a higher level security is required. When and only door closed, read valid card/ input PIN on access host, door will open; when and only door closed, read valid card/ input PIN on external reader, door will open. Remark: The valid card/pin is only for users of Zone, users of zone are invalid. 9.7 Anti-passback for Single Door In this mode, access host install outside is for entering door, external reader inside for exiting door, they build up a single door anti-passback system, access host is the anti-passback master unit. The users can only enter door when read valid card on access host, and exit from the inside external reader. If without the entering record from access host, the users cannot exit from the inside reader, also the users can't enter in twice without the first exit record. Remark: This is only for card users of Zone, PIN users of Zone and all users of Zone are invalid. N00 N00 L N Input AC00-0V Access Host (Enter Door ) Red Black Green White Inside Door Outside Door External Reader(Enter Door ) Red Black Green White Door Bell Alarm Door Contact Door Contact Exit Button Exit Button Lock (A / B) Short-Circuit Wire N00 N00 Lock (A / B) L N Input AC00-0V External Reader( Exit Door ) Red Black Green White Inside Door Outside Door Door Bell Alarm Door Contact Exit Button N00 N00 Short-Circuit Wire Lock (A / B) Access Host ( Enter Door ) Red Black Green White 5 6

16 9.8 Anti-passback for Two Doors In this mode, access host on door is anti-passback master unit,and external reader on door as the anti-passback auxiliary unit. Then they build up a two doors anti-passback system, which is normally used for parking lot. Application Scene Graph The users can only enter door when read valid card on access host, and exit from door when read valid card on external reader. If without the entering record from door, the users cannot exit from the door, also the users can't enter in twice without the first exit record. Remark: This is only for card users of Zone, PIN users of Zone and all users of Zone are invalid. Access Host Access Host Door Door Access Door Door Host Standalone for single door Figure Figure Standalone for two doors L N Input AC00-0V Access Host (Enter Door ) Red Black Green White Inside Door Door Bell Alarm Door Contact Exit Button N00 N00 Lock (A / B) Short-Circuit Wire Door Access External Door Host Reader Door External Reader Door Outside Door External Reader(Enter Door ) Red Black Green White Door Contact Exit Button N00 N00 Lock (A / B) Access Host With external reader for two doors Two units interlocked for two doors 7 8

17 Can t open door after inputting user's PIN Use as user's PIN is the initial value, can't be used to open doors, unless after resetting them to other ~6 digits Access Host (Outside Door) External Reader (Inside Door) Door ( Entrance) Access Host Door (Exit) External Reader Alarm under normal situation No reaction when reading card Light leaking when install access host Machine is not on standby status Leaning on wall closely when install access host Exit by pressing * until logo light turns to white Anti-passback for single door 0. Simple Troubleshooting Anti-passback for two doors Keypad light off Set keypad light mode improperly. Set the keypad light to always On or automatic mode. Under automatic mode, keypad light will on when people approaching Fault Phenomenon Fault Cause Reason & Solution Reading distance is too close. Card problem. Switch power supply interferences card reading. Please use original made card. Wiring power supply and access host shell to ground wire Cannot enter Administrator setting mode Forget master code Reset to Factory Default, default master code is , need to reset conditions and specifications, but users' information is still retained Set user PIN failed. Wrong way of PIN setting. Setting PIN under card reading mode st. Corresponding to users ID, digit of users PIN should be (Zone ) or (Zone ). User PIN cannot be. User PIN only can be -6 digits. setting PIN under card reader mode is not allowed For other issues beyond above, welcome to contact our technicians for more details. 9 0

18 . Packing List Name Qty Remark Name Qty Remark User Manual User Manual Quick Use Guide Fixing Location Sticker Used for locating installation position. Fixing Location Sticker Used for locating installation position Self Tapping Screw X0 mm Self Tapping Screw X0 mm Rubber Bungs 6X mm Rubber Bungs 6X mm Screw Driver Diode IN 00 Diode Wire Four Wires (Corlor: Yellow X, Red, Black) Manager Cards Manager Add Card & Manager Delete Card User Cards EM Thin Card Self Tapping Screw X5 mm Rubber Bungs 6X0 mm Power Connecting Wire Length: 50 cm Screw Driver

P10 - Standalone Access Controller and Reader

P10 - Standalone Access Controller and Reader www.quantek.co.uk T: 01246 417113 P10 - Standalone Access Controller and Reader 1 Description & Features: P10 is a waterproof standalone access control, reading EM&HID card, it uses advanced Microprocessor,

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

AR-721U/721K/661U User s Guide

AR-721U/721K/661U User s Guide AR-72U/72K/66U User s Guide Feb. 6, 2004 Table of Contents Page. Main Feature --------------------------------- 3 2. AR-72U Installation --------------------------------- 4 2. Steps ---------------------------------

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

PROXIMITY CARD READERS C-10, C-20, C60, C70

PROXIMITY CARD READERS C-10, C-20, C60, C70 Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0 CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection

More information

Business/Home GSM Alarm System. Installation and User Manual

Business/Home GSM Alarm System. Installation and User Manual Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene

More information

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP

More information

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.eu WARNINGS Read carefully

More information

VARIO PROX CARD READER INSTALLATION MANUAL

VARIO PROX CARD READER INSTALLATION MANUAL VARIO PROX CARD READER INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION...2 1.1 Legend...3 1.2 Terminology...4 2.0 MOUNTING...5 3.0 WIEGAND CONNECTION...6 4.0 AUX BUTTON INPUT...7 5.0 INSTALLER PROGRAMMING...8

More information

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad) KCIENSBP KCIEN Heavy Duty Stainless Steel Illuminated Keypads Range: DIGICODE (Stand-Alone Keypad) INSTALLATION MANUAL Features: Input voltage: 12V to 24V AC or 12V to 48V DC Illuminated keys Heavy duty

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-A

More information

GV- RK1352 Card Reader

GV- RK1352 Card Reader GV- RK1352 Card Reader The GV-RK1352 is a card reader with keypad, designed to recognize PIN codes, identification cards or both. Featured with the Wiegand and RS-485 outputs, the unit can be connected

More information

Intelligent GSM Auto-Dial Alarm System

Intelligent GSM Auto-Dial Alarm System Auto-dial Alarm System Intelligent GSM Auto-Dial Alarm System Profile For a better understanding of this product, please read this user manual thoroughly before using it. 2013.2.V1.0 Auto-dial Alarm System

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASHV1124-A-EN 2011 GeoVision, Inc.

More information

Automatic Telephone Dialer TD-101(W)

Automatic Telephone Dialer TD-101(W) Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages

More information

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power) MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc. SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection

More information

Business/ Home GSM Alarm System

Business/ Home GSM Alarm System Business/ Home GSM Alarm System BUSINESS/HOME GSM ALARM SYSTEM POWER STATUS RECORD SIGNAL User Manual Profile For a better understanding of this product, please read this user manual thoroughly before

More information

MOBILE CALL GSM Alarm System User s Manual

MOBILE CALL GSM Alarm System User s Manual MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction Alarm Host Diagram

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Adaptability to Enhanced Security

Adaptability to Enhanced Security Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access

More information

Users Manual of GSM Home Alarm System with Photo-taken

Users Manual of GSM Home Alarm System with Photo-taken GSM-IV REMOTE CAMERA MANNAL The Excellent GSM + Camera alarm system bases on the GSM network, integrates the communication technology, can automatic screen a photo with the intruder or burglar, and send

More information

Adaptability to Enhanced Security

Adaptability to Enhanced Security Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access

More information

DC-8706K Auto Dial Alarm System

DC-8706K Auto Dial Alarm System DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power

More information

Intelligent GSM Auto-dial Alarm System User s Manual

Intelligent GSM Auto-dial Alarm System User s Manual Intelligent GSM Auto-dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. [Function Instruction] [Control Panel Introduction]

More information

Home Security Alarm System

Home Security Alarm System Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better

More information

COLOR VIDEO DOOR PHONE CDV-71BE/D

COLOR VIDEO DOOR PHONE CDV-71BE/D COLOR VIDEO DOOR PHONE CDV-71BE/D 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed

More information

INSTALLATION GUIDE. www.security.soundstream.com FCC ID NOTICE

INSTALLATION GUIDE. www.security.soundstream.com FCC ID NOTICE AL.1 AUTO SECURITY SYSTEM INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device

More information

STATUS POWER MONITOR ALARM SOS DISARM

STATUS POWER MONITOR ALARM SOS DISARM STATUS POWER MONITOR ALARM SOS DISARM I. Features II. Preparation before use III. Host 1.LED status explanation 2. Host panel IV. System Settings 1. Coding of wireless sensors 2. Exit coding 3. Settings

More information

GSM Alarm System User Manual

GSM Alarm System User Manual GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following

More information

Shunt lock function 3066

Shunt lock function 3066 Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning

More information

How To Program An Autodialer

How To Program An Autodialer GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

GSM Home Alarm System User Manual. http://www.usmartbuy.com

GSM Home Alarm System User Manual. http://www.usmartbuy.com GSM Home Alarm System User Manual http://www.usmartbuy.com 1 1. Factory default Normally, all sensors in the big box have been coded (learnt) to the control host Operation Password: 0000 Long-Distance

More information

Business/Home GSM. Alarm System(III) Installation and Users guide

Business/Home GSM. Alarm System(III) Installation and Users guide Business/Home GSM Alarm System(III) Installation and Users guide I. General information: GSM 900/1800/1900 bands, can be used all over the world. Full duplex communication with the base. Monitor environment

More information

Business/Home. GSM Alarm system

Business/Home. GSM Alarm system Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900

More information

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals SSW-iLM Keypad Note: This product is designed to be installed and serviced by security and lock industry professionals Specifications Case dimensions: 6 1/2 L x 1 3/4 W x 1 1/8 D Electrical: 5-12VDC Only

More information

Installation manual. Version 1.1. www.videx-security.com

Installation manual. Version 1.1. www.videx-security.com Installation manual Version 1.1 www.videx-security.com 2 Table of Contents MANUAL INTRODUCTION... 4 SYSTEM INTRODUCTION... 4 SYSTEM COMPONENTS... 5 CONTROLS... 6 3.5A 13.8Vdc PSU... 6 CONTROL PCB... 6

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

User s Information Guide R1A

User s Information Guide R1A HSC505-R Home Security Controller - User Manual Release R1a Pi HSC505 and Pi HSC505R Home Security Controller User s Information Guide R1A Page 1 QD Dynamics (Pty) Ltd reserves the right to make changes

More information

MANUAL Remote Programmer XM3

MANUAL Remote Programmer XM3 MANUAL Remote Programmer XM3 Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration

More information

F11 User Manual. Version:1.0 Date:Jul. 2010

F11 User Manual. Version:1.0 Date:Jul. 2010 F11 User Manual Version:1.0 Date:Jul. 2010 Introduction: This document mainly introduces the user s operation of F11. About the device installation please refer to F11 Installation Guide. F11 User Manual

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.

More information

LCD -based Intelligent Burglar Alarm System. User Guide. Ver 2.0

LCD -based Intelligent Burglar Alarm System. User Guide. Ver 2.0 LCD -based Intelligent Burglar Alarm System User Guide Ver 2.0 Table of Content 1. Introduction... 2 1.1 General Description... 3 1.2 System Features... 3 2. Anatomy of the LCD-based Intelligence Burglar

More information

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it. New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter

More information

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS INSTALLATION MANUAL Before you begin the installation Read the INSTRUCTIONS! Always use a multi-meter when verifying vehicle wiring. Before mounting the

More information

User Manual. BARKODES BİLGİSAYAR SİSTEMLERİ ARF Panel

User Manual. BARKODES BİLGİSAYAR SİSTEMLERİ ARF Panel 1 User Manual Barkodes Bilgisayar Sistemleri Bilgi İletişim ve Yazılım Tic. Ltd. Şti. Adres: Altay Çeşme Mahallesi Sanayi Sokak No:8 Demirli Sitesi B Blok Maltepe-İstanbul/Turkey Tel: + 90 (216) 442 20

More information

User Manual Color video door phone

User Manual Color video door phone User Manual Color video door phone CDV-70KM Thank you for purchasing COMMAX products. Please carefully read this User s Guide (in particular, precautions for safety) before using a product and follow instructions

More information

Security GSM Alarm System

Security GSM Alarm System KONLEN TECHNOLOGY LIMITED Website: www.konlen.com Add:, 3/F, Building5, Kaijieda Industry Zone, Huachang Road, Longhua, Shenzhen China Tel: +86-(0)755-29709632 E-mail: konlensales@126.com klarm@konlen.com

More information

3 Specification. Master Chip Broadcom 1190. Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

3 Specification. Master Chip Broadcom 1190. Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice I20-T Door Phone 1 Description I20-T Voice Access control is a digital IP door phone with Fanvil Voip Solutions (Broadcom chip 1190), stable and reliable. FDSP ensure voice loud and clear. Good looking,

More information

ACCESS CONTROL SYSTEM

ACCESS CONTROL SYSTEM ACCESS CONTROL SYSTEM Flexible, Expandable, Economical. The i-pass system comprises of the i-pass controller built with state of the art technology to provide reader access for up to 16 doors and 32 elevator

More information

1R / 4-BUTTON SERIES

1R / 4-BUTTON SERIES Button 1 1R / 4-BUTTON SERIES VEHICLE SECURITY SYSTEM Standard Features: Two 4-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren Dual stage impact detector Remote

More information

Intruder Alarm System

Intruder Alarm System Intruder Alarm System GSM & PSTN Wireless and Wired Touch Model 2013-01 V1.0.0 Statment This equipment must be installed and used in strict accordance with the instructions given in this user documentation.

More information

GSM Door Phone System

GSM Door Phone System GSM Door Phone System System Installation, Setting and Operation Manual User Manual (263-S V1) Please read this user manual completely before operating this system and keep it in a safe place for future

More information

Wireless Alarm system s manual

Wireless Alarm system s manual MOUNTVIEW TECH AUSTRALIA PTY LTD Wireless Alarm system s manual ADS A180 Series ADS Security 1/11/2011 1. Before You Begin For your safety and the safety of others, and to ensure that you get the most

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

PiSector Home security systems

PiSector Home security systems PiSector Home security systems User Manual (ALM-S02) Read manual fully before use. PiSector Inc., USA, www.pisector.com Thank you for purchase this alarm system, For proper use and your safety, please

More information

Iphone & Android App Smart GSM Home Alarm System

Iphone & Android App Smart GSM Home Alarm System Iphone & Android App Smart GSM Home Alarm System PST-GA242Q User Guide Version V14.3 Dear User, Thanks for selecting the intelligent alarm system. Please read through this guide before installation so

More information

Operating Instructions. Keypad 2605..

Operating Instructions. Keypad 2605.. Operating Instructions Keypad 605.. Contents Device description...4 Device presentation...5 Areas of application...6 Operation...8 Acknowledgement signals... 10 Start-up sequence... 11 Connection terminals...1

More information

Version:G300 V2.0 11.04. Business/Home GSM Alarm System. Installation and Users' Guide. ( 99 wireless zones)

Version:G300 V2.0 11.04. Business/Home GSM Alarm System. Installation and Users' Guide. ( 99 wireless zones) Version:G300 V2.0 11.04 Business/Home GSM Alarm System Installation and Users' Guide ( 99 wireless zones) Brief Introduction: GSM 850/900/1800/1900 bands, can be used in most parts of the world Full duplex

More information

Six-defense zone Display Alarm System. User Manual

Six-defense zone Display Alarm System. User Manual Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode

More information

Auto Dialer. Manual E-921APQ E-921GPQ

Auto Dialer. Manual E-921APQ E-921GPQ Troubleshooting: Auto dialer will not arm/disarm Auto dialer will not dial out Unit doesn t respond to a call-back Difficulty in activating room monitor by telephone remote control Make sure that you have

More information

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL

NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL NESS D16 16 Zone Control Panel and Dialler OWNER S MANUAL REVISION 2, JULY 2001 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia

More information

PK5500 v1.1 Installation Instructions

PK5500 v1.1 Installation Instructions PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on

More information

How To Control A Car Alarm On A Car With A Remote Control System

How To Control A Car Alarm On A Car With A Remote Control System MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock

More information

Installation Instructions

Installation Instructions Installation Instructions For WiFi/LAN Video Intercom Manual Version 2 BFT Americas 6100 Broken Sound Parkway N.W. Suite 14, Boca Raton, FL 33487 www.bft-usa.com Toll Free: 877-995-8155 Office: 561-995-8155

More information

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully. WIRELESS AUTODIAL HOME ALARM SYSTEM AM2000 Instructions for use Important! Please read these instructions carefully. IMPORTANT 1 IDENTIFICATION PLEASE CONTACT BEFORE RETURNING THIS PRODUCT TO THE RETAILER

More information

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance

More information

USER MANUAL V5.0 ST100

USER MANUAL V5.0 ST100 GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2

More information

SHENZHEN PROYU BIOMETRIC T/A & A/C TERMINAL QUOTATION

SHENZHEN PROYU BIOMETRIC T/A & A/C TERMINAL QUOTATION Biometric Time Attendance Terminal ITEM NO. MAIN SPECIFICATION PY-B3 * Fingerprint Cap.: 1,500 * Record Cap.: 50,000 * Communication: RS232;485;TCP/IP * Workcode: * Check in/out, Break in/out PY-X628 *

More information

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel +972-3-5587722 +972-3-5500442 support@pima-alarms.com http://www.pima-alarms.com

More information

GSM home alarm system s manual

GSM home alarm system s manual GSM home alarm system s manual I. Main features: 1, Eight wireless LED zone, and four wired zone 2, Two-way to communication 3, The system supports the GSM cell phones, no need the fixed telephone line.

More information

WIRELESS HOME ALARM SYSTEM (WHA1)

WIRELESS HOME ALARM SYSTEM (WHA1) WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

SECURITY SYSTEM ADP-CAN

SECURITY SYSTEM ADP-CAN INSTALLATION INSTRUCTION SECURITY SYSTEM ADP-CAN Introduction Motorcar security system ADP-CAN is for motorcars provided with CAN net. It is for the work with the motorcar factory security systems or remote

More information

9452/9453 Installation and User Guide

9452/9453 Installation and User Guide 9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and

More information

TUTA B12. User Manual GSM REMOTE CAMERA. Manual version 3.0

TUTA B12. User Manual GSM REMOTE CAMERA. Manual version 3.0 TUTA B12 GSM REMOTE CAMERA User Manual Manual version 3.0 TUTA Series GSM Remote Camera Thank you for purchasing the TUTA camera. This camera is a remotely controlled image-capturing device consisting

More information

Version Date Author Description 1.00 19.07.2010 Jpo First version 1.01 21.12.2010 Jpo FET output descriptions made clearer 1.02 04.02.

Version Date Author Description 1.00 19.07.2010 Jpo First version 1.01 21.12.2010 Jpo FET output descriptions made clearer 1.02 04.02. +3 # Version Date Author Description 1.00 19.07.2010 Jpo First version 1.01 21.12.2010 Jpo FET output descriptions made clearer 1.02 04.02.2011 Jpo Reset button added 1. Purpose of this user manual...

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

INSTALLATION MANUAL XM3 Reader

INSTALLATION MANUAL XM3 Reader INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration

More information

PAC1 Door Access Controller

PAC1 Door Access Controller PAC1 Door Access Controller Series 2 IMPORTANT DIFFERENCES FROM SERIES 1 1. A PACDL data logger revision 4.0 or higher attached to the DLOG terminal is able to program all features (i.e. times, relay type,

More information

User Guide. Model: MAS-WA-SYS

User Guide. Model: MAS-WA-SYS User Guide Model: MAS-WA-SYS CONTENTS Section : Getting started... 4. General system overview. Introduction to the system.3 Items included with the system.4 Introduction to the Wireless Alarm Panel.5 Introduction

More information

CipherLab 5100 Time Attendance Utility Manual

CipherLab 5100 Time Attendance Utility Manual CipherLab 5100 Time Attendance Utility Manual K:\Products\Product Technical\BI\BI-PC5100T\CipherLab5100TimeAttendnaceUtilityManual0707-process.doc Page 1 / 13 1 Login A popup form as follows will appear

More information

HAI Access Control. The HAI Access Control Card Reader can be used for:

HAI Access Control. The HAI Access Control Card Reader can be used for: HAI Access Control HAI Access Control allows you to access doors by opening an electric or magnetic lock, arm and disarm the security system, and achieve many home automation functions such as controlling

More information

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual SUPA8 Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS... 1 INSTALLATION OF THE SECURITY SYSTEM... 2 COMMISSIONING THE DIALLER PANEL... 5 ZONE INPUT CONNECTIONS... 7 PANEL

More information

Wireless Auto-dial Intruder Alarm System

Wireless Auto-dial Intruder Alarm System Wireless Auto-dial Intruder Alarm System User Manual User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Features and Function 1.

More information

User Manual GSM Alarm System. www.deltasecurity.cn. All rights reserved by Delta Security Co., Ltd

User Manual GSM Alarm System. www.deltasecurity.cn. All rights reserved by Delta Security Co., Ltd User Manual GSM Alarm System All rights reserved by Delta Security Co., Ltd Dear Clients, Thank you for using our GSM Alarm System. We are committed to giving you the best home security available today

More information

Emergency Dialer DIAL-ALERT MODEL: AD-105. www.skylinkhome.com

Emergency Dialer DIAL-ALERT MODEL: AD-105. www.skylinkhome.com www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-105 If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual, please :

More information

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION 2014 Ferport/Armas has over 30 years been synonymous with technology, reliability and experience in

More information

MOBILE CALL GSM alarm system

MOBILE CALL GSM alarm system MOBILE CALL GSM alarm system User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. - 1 - Catalogue: Function Introduction 2 SMS Number

More information

Home alarm system. User s manual. Profile To better understand this product, please read the user s manual carefully before using.

Home alarm system. User s manual. Profile To better understand this product, please read the user s manual carefully before using. Home alarm system User s manual Profile To better understand this product, please read the user s manual carefully before using. Features; 1. 1-99 LED wireless defense zone, with digital number to show

More information

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

Fleets Vehicle GPS Tracker TS20 User Manual. (Version 1.0)

Fleets Vehicle GPS Tracker TS20 User Manual. (Version 1.0) Fleets Vehicle GPS Tracker TS20 User Manual (Version 1.0) Index Contents 1. Package Contents... 3 2. Features and Specifications... 3 3. Mechanical Size... 4 4. Knowledge before Usage... 4 4.1 Factory

More information

LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets LW-2000-3A Wireless Auto Dial Alarm System Sentry Plus User Manual By Global Gadgets Main Features Simple to use keypad for operation and control. The system can store up to 9 telephone numbers: positions

More information

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter MODEL PRO-9744 INSTALLATION MANUAL Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter This System Allows The Transmitter Buttons To Be

More information

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder P R O D U C T G R O U P OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder Manual # 600-0901 November 30, 1999 Rev. D - 99068 DESCRIPTION The ST-888 Mobilecall Display Decoder is a desktop

More information

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142

More information