Heating and Drying Product Guide

Size: px
Start display at page:

Download "Heating and Drying Product Guide"

Transcription

1 Heating and Drying Product Guide

2 Aggreko engineers have vast experience designing and delivering commercial heating and drying packages across a range of industries. Construction Facilities management Shipping Oil and gas These include the construction, facilities management, shipping and oil and gas sectors - environments where climate and moisture control applications are critical to operational success. Using our extensive range of heaters, dehumidifiers, boilers and supporting power and temperature control fleet, we ll find a solution to your most challenging projects. 01 Product Guide Introduction

3 Construction and refurbishment We understand that the main goal of a construction or fit-out contractor is to complete projects on time and within budget. We therefore design our heating and drying packages to speed up project completions and prevent delays due to poor weather and ambient conditions. Applications: Curing or drying concrete, screed and building structures, ready for fit-out Maintaining temperatures when fitting specialist flooring Drying paint, coatings or plastering Ceiling tile humidity control Dew point protection for critical electrical installations Moisture ingress protection for hard wood veneers Listed building repair / preservation Construction and refurbishment Product Guide 02

4 Asset preservation Our climate control packages ensure expensive assets or perishable goods are kept in optimum condition. By controlling moisture and humidity, we ll help reduce the risk of condensation, corrosion and spoilage. From preventing the oxidisation of exposed metals on laid-up ships, to controlling the dew point within sensitive areas of museums we can help! 03 Product Guide Asset preservation

5 Ship building Our team has years of experience delivering projects using heaters and dehumidifiers to facilitate the painting and coating of vessels. While our dehumidifiers can prevent the rusting of a vessel s surface prior to painting and coating, our heaters can then speed up the drying time. Ship building Product Guide 04

6 Emergency heating and drying When you experience a disaster, such as a flood or a fire, the Aggreko team is here to help. With 18 local service centres across the UK and Ireland, we ll rapidly mobilise and install our kit 24 hours a day, 365 days a year. We aim to get you back up and running fast. Each year we help hundreds of companies to: Dry out water or flood damaged buildings, eliminating the need to replace and reconstruct. Provide temporary, back-up heating, should their HVAC system fail. Control a building s humidity post fire damage. 05 Product Guide Emergency heating and drying

7 Product range Contact us now on: T: Product range Product Guide 06

8 Electric heaters For both indoor and outdoor applications, our electric heaters will keep your operations running and your projects on track. Our industrial heaters are tough, portable and ideal for either largescale or localised temporary heating applications. 18 kw Electric heater 42 kw Electric heater 45 kw Electric heater Contact us now on: T: Product Guide Electric heaters

9 18 kw Electric heater The 18 kw electric heater has been designed for applications that require a low noise solution. The heavy duty castor wheels make it ideal for commercial use. It can be switched down to suit a range of requirements and most models include an internal thermostat option. Airflow dry air: 1700 m 3 /h Power supply: 390/415V 3p + E 50 Hz Elec. supply running: 29 A Elec. supply min: 17 A Plug type: 32 A 5 pin Ducting size: 305 mm 700 mm 650 mm 600 mm 35 kg Electric heaters Product Guide 08

10 42 kw Electric heater The 42 kw heavy duty electric heater is designed for applications that require good airflow over long distances. It is easy to manoeuvre with heavy duty castor wheels, fork pockets and lift eye points. It has a remote thermostatic control if required. Airflow dry air: 7000 m 3 /h Power supply: 415V 3p + E 50 Hz Elec. supply running: 63 A Elec. supply min: 22 A Plug type: 63 A 5 pin Ducting size: 500 mm 1150 mm 740 mm 1110 mm 114 kg 09 Product Guide Electric heaters

11 45 kw Electric heater This high specification heater incorporates a digital display to control heat levels, allowing for very tight temperature settings. The unit also has heavy duty castor wheels, fork pockets and lift eye points. If required it can be internally or remotely thermostatically controlled. Airflow dry air: 5100 m 3 /h Power supply: 415V 3p + E 50 Hz Elec. supply running: 63 A Elec. supply min: 20 A Plug type: 63 A 5 pin Ducting size: 500 mm 1090 mm 574 mm 1120 mm 150 kg Electric heaters Product Guide 10

12 Indirect diesel fired heaters Aggreko s Indirect Diesel Fired (IDF) heaters are fully fume-free with no additional moisture. High quality fuel filters provide trouble-free running and all can be run with an external thermostat to save on fuel. 65 kw IDF heater 125 kw IDF heater 200 kw IDF heater 350 kw IDF heater Contact us now on: T: Product Guide IDF heaters

13 65 kw IDF heater This is the smallest of the IDF range. It is fully fume-free with no additional moisture. Best quality fuel filtering ensures trouble-free running. Its own fuel tank allows for independent use. The heater is dual voltage and can run off 110 and 240 volts. Airflow dry air: 5100 m 3 /h Power supply: 110 / 240 V Elec. supply running: 12 A Elec. supply min: 6 A Plug type: 16 A 4343 CEE FORM Fuel consumption: 1.3 gal/h (5.9 L/h) Fuel tank size: 22 gal (100 L) Ducting size: 500 mm 1600 mm 800 mm 1500 mm 380 kg wet IDF heaters Product Guide 12

14 125 kw IDF heater This heavy duty heater has a powerful fan, allowing many lengths of flexible ducting. The heater has its own 24 hour running fuel tank allowing for independent use. Airflow dry air: m 3 /h Power supply: 380/415V 3p N+E 50 Hz Elec. supply max: 10 A Plug type: 32 A 5 pin Fuel consumption: 2.7 gal/h (12.3 L/h) Fuel tank size: 70 gal (318 L) Ducting size: 500 mm 2900 mm 1230 mm 1600 mm 1475 kg wet 13 Product Guide IDF heaters

15 200 kw IDF heater The 200 kw heater is designed for areas that require a good heat/flow with low background noise. Airflow dry air: m 3 /h Power supply: 400V 3p N+E 50 Hz Elec. supply max: 7.5 A Plug type: 32 A 5 pin Fuel consumption: 4.2 gal/h (18 L/h) Ducting size: 500 mm 2400 mm 810 mm 1360 mm 605 kg IDF heaters Product Guide 14

16 350 kw IDF heater The 350 kw heater is the largest of the Aggreko heater fleet. This machine has the latest heat controls and frequency slow-start. It can also be switched down to a lesser heat output if required. High flow and low noise make for an excellent all-round heater. Airflow dry air: 25,000 m 3 /h Power supply: 380/415V 3p N+E 50 Hz Elec. supply max: 20 A Plug type: 32 A 5 pin Fuel consumption: 7.8 gal/h (38 L/h) Ducting size: 500 mm 3800 mm 1200 mm 1890 mm 1100 kg 15 Product Guide IDF heaters

17 Heat pump chillers Aggreko heat pump chillers can be used for both heating and cooling applications, reducing the equipment footprint should both be required. With the addition of an air handling unit, the heat pumps become efficient space heaters providing fume-free, warm dry air. 100 kw Heat pump chiller 250 kw Heat pump chiller Contact us now on: T: Heat pump chillers Product Guide 16

18 100 kw Heat pump chiller The 100 kw refrigeration heat pump can be used if a project has electrical power available and use of open-fire systems is not possible. The heat pump is very energy efficient: for every kw of electrical energy consumed, up to 3 kw of thermal heat can be obtained. Due to the nature of refrigeration heat pumps, special care must be taken when operating the units at sub-zero ambient temperatures, ask an Aggreko representative for advice. Heating capacity: 119 kw (@ 45 C LWT 7 C ambient temperature) Absorbed power: 34 kw Temperature range: C Fluid flow: 19 m 3 /h Power supply: 400V 3p 50 Hz 3000 mm 1200 mm 2520 mm 1904 kg 17 Product Guide Heat pump chillers

19 250 kw Heat pump chiller The 250 kw refrigeration heat pump is ideal for heating applications where electrical power is available, and use of open-fire systems is not possible. The heat pump offers excellent energy efficiency: for every kw of electrical energy used, up to 3 kw of thermal heat can be obtained. Due to the nature of refrigeration heat pumps, special care must be taken when operating the units at sub-zero ambient temperatures, ask an Aggreko representative for advice. Heating capacity: 255 kw (@ 45 C LWT 7 C ambient temperature) Absorbed power: 79 kw Temperature range: C Fluid flow: 39 m 3 /h Power supply: 400V 3p 50 Hz 4700 mm 1200 mm 2520 mm 3210 kg Heat pump chillers Product Guide 18

20 DX air conditioner heat pumps Aggreko s DX air conditioner heat pumps offer high levels of heating, cooling and ventilation from a low electrical input. The compact construction of these self-contained units makes them an ideal solution for applications where space, as well as power input, can be a problem. ACHP80 air conditioner heat pump ACHP160 air conditioner heat pump ACHP350 air conditioner heat pump 19 Product Guide DX air conditioner heat pumps Contact us now on: T:

21 ACHP80 air conditioner heat pump Our smallest air conditioner heat pump has a highly reliable and practical design, specifically for the rental market. The unit is simple and quick to install, with no pumps, pipes, air handlers or water required for comfort heating or cooling. It has a fully automatic operating mode to maintain the required temperature and standard 20 ducting connections designed to fit with Aggreko s ducting range. Air volume: 7000 m 3 /h Heating eurovent conditions: 42 kw Absorbed power: 14 kw Temperature rise: 18 K 2300 mm 1980 mm 1320 mm 950 kg Duct connection in: 1 x 500 mm Duct connection out: 1 x 500 mm Electrical connection: Cee-form 63 A 5p Eurovent conditions: Air inlet 20 C 50% rh Ambient 7 C 86% rh DX air conditioner heat pumps Product Guide 20

22 ACHP160 air conditioner heat pump Offering heating, cooling and ventilation from one unit, the ACHP160 air conditioner heat pump is very practical when space is limited. The direct expansion (DX) design allows rapid plug and play installation. It has energy efficient compressor units and is ideal where low noise levels are required. Air volume: m 3 /h Heating eurovent conditions: 93 kw Absorbed power: 34 kw Temperature rise: 18 K 3800 mm 2300 mm 1900 mm 2500 kg Duct connection in: 2 x 500 mm Duct connection out: 2 x 500 mm Electrical connection: Cee-form 125 A 5p Eurovent conditions: Air inlet 20 C 50% rh Ambient 7 C 86% rh 21 Product Guide DX air conditioner heat pumps

23 ACHP350 air conditioner heat pump The largest of our air conditioner heat pump range remains compact and practical in design, ideal for projects where space is restricted. Comfort heating, cooling and ventilation can be achieved very quickly due to its plug and play design. It has a fully automatic operating mode to maintain the required temperature and standard 20 ducting connections designed to fit with Aggreko s ducting range. Air volume: m 3 /h Heating eurovent conditions: 214 kw Absorbed power: 70 kw Temperature rise: 18 K 5800 mm 2232 mm 2605 mm 4900 kg Duct connection in: 2 x 800 mm Duct connection out: 2 x 800 mm Electrical connection: Busbar M12 Eurovent conditions: Air inlet 20 C 50% rh Ambient 7 C 86% rh DX air conditioner heat pumps Product Guide 22

24 Desiccant dehumidifiers 23 Product Guide Desiccant dehumidifiers Aggreko s desiccant dehumidifiers are a cost-effective way to reduce the effects of moisture damage. The units are discreet (one unit can dry out very large areas) and do not require background heat for them to work. In-built heater controllers ensure maximum performance is maintained all year round and help keep running costs to a minimum. If your site access is tight, then all units can be placed outside. By using flexible ducting, the air can then be directed into a specific area as required. Temperature control accessories are available, including a variety of compatible ducting and remote humidistats that easily incorporate into the package. KT1600 Desiccant dehumidifier KT2000 Desiccant dehumidifier KT7000 Desiccant dehumidifier Contact us now on: T:

25 KT1600 Desiccant dehumidifier The KT1600 desiccant dehumidifier is a heavy duty machine suitable for many applications. Made of stainless steel, this unit combines smart appearance with excellent performance. Its built-in heater controller ensures maximum efficiency is maintained all year round. Remote humidistat control is available when required. Airflow dry air: 1600 m 3 /h Power supply: 380/415V 3p N+E 50 Hz Plug type: 32 A 5 pin Electrical supply running: 20 A Electrical supply min: 15 A Ducting size dry: 205 mm Ducting size wet: 205 mm Keep dry area approx: 4268 m 3 Dry out area approx: 2845 m mm 710 mm 1520 mm 385 kg Desiccant dehumidifiers Product Guide 24

26 KT2000 Desiccant dehumidifier The KT2000 desiccant dehumidifier is a heavy duty machine suitable for many applications. Its variable fan speed ensures the exact air flow for optimum performance. An electronically-controlled regeneration heater maintains the user humidity level for maximum energy savings. Remote humidistat control is available when required. Airflow dry air: 1700 / 2000 m³/h Power supply: 380/415V 3p N+E 50 Hz Plug type: 32 A 5 pin Electrical supply running: 26 A Electrical supply min: 15 A Ducting size dry: 205 mm Ducting size wet: 205 mm Keep dry area approx: 5335 m³ Dry out area approx: 3556 m³ 2200 mm 7700 mm 1480 mm 410 kg 25 Product Guide Desiccant dehumidifiers

27 KT7000 Desiccant dehumidifier The KT7000 desiccant dehumidifier is a heavy duty machine suitable for many applications. Made of stainless steel, this unit combines smart appearance with excellent performance. Its built-in heater controller ensures maximum efficiency all year round. Remote humidistat control is available when required. Airflow dry air: 7000 m 3 /h Power supply: 380/415V 3p N+E 50 Hz Plug type: Hard wired Electrical supply running: 112 A Electrical supply min: 32 A Ducting size dry: 305 mm Ducting size wet: 205 mm Keep dry area approx: 17,566 m 3 Dry out area approx: 11,730 m mm 1200 mm 1650 mm 1100 kg Desiccant dehumidifiers Product Guide 26

28 Boilers Aggreko s oil-fired mobile boilers offer a self-contained, complete hot water package ready for use across a wide range of applications. They are compact and ideal for spaces with a small footprint. A built-in heat exchanger control valve allows them to quickly and accurately operate within a range of fluid temperatures. With an ability to reach 10 bar, they re suitable for applications within high rise buildings. With the addition of an Aggreko air handling unit, they become an efficient space heater providing fume-free warm dry air. 250 kw Boiler 500 kw Boiler Contact us now on: T: Product Guide Boilers

29 250 kw Boiler The 250 kw boiler has a small footprint for sites where space is limited. The two stage burner and thermostat allow stable temperature regulation. This boiler is very energy efficient, complying to the latest environmental exhaust legislation. Heating capacity (high/low): 250 / 180 kw Fuel consumption (high/low): 22 / 15 L/h Fluid temperature range: C Fluid flow: 11 m³/h Power supply: 230 V 1ph / 50 Hz 3400 mm 1000 mm 1622 mm 1922 kg Boilers Product Guide 28

30 500 kw Boiler The 500 kw boiler has a small footprint for sites where space is limited. The two stage burner and thermostat allow stable temperature regulation. This boiler is very energy efficient, complying to the latest environmental exhaust legislation. Heating capacity (high/low): 515 / 370 kw Fuel consumption (high/low): 55 / 39 L/h Fluid temperature range: C Fluid flow: 22 m³/h Power supply: 400 V 3ph / 50 Hz 3700 mm 1200 mm 1622 mm 2900 kg 29 Product Guide Boilers

31 Useful conversions Area: 1 m 2 = ft 2 1 ft 2 = m 2 Temperature: ºC = (ºF-32) x 5/9 ºF = (ºCx9/5) + 32 Air flow: Capacity: Water flow: 1 m 3 /s = 2119 cfm 1000 cfm = /h 1 kg = lb 1 lb = kg 1 L = 0.22 gal 1 gal = L 1 L/s = 13.2 g/m 1 g/m = L/s Heat: 1 kw = 3412 BTU/h 1000 BTU/h = kw 1 Therm = 29.3 kw Refrigeration: 1 kw = Ton R 1 Ton R = 3.12 kw Heat transfer: 1 W/m 2 ºC = 0.176BTU/h sqft ºF 1 BTU/h sqft ºF = W/m 2 ºC Volume: 1 m 3 = ft 3 Linear: 1 ft 3 = m 3 1mm = inch 1 in = 25.4 mm 1 m = 3.28 ft 1 ft = m Velocity: Pressure: Power: 1 m/s = ft/min 1000 ft/min = 5.08 m/s 1000 pascals = 100 mm water gauge 1 inch WG = 25mm WG 1 bar = 14.5 psi 1 psi = bar 1 kw = 1.34 HP 1 HP = kw 1 inch WG = 25mm WG 1 bar = 14.5 psi 1 psi = bar Useful conversions Product Guide 30

32 Head Office Aggreko UK Ltd Aggreko House, Orbital 2, Voyager Drive, Cannock, Staffordshire, WS11 8XP T: E: hire@aggreko.co.uk Aggreko Ireland Ltd Clonminam Industrial Estate, Portlaoise, Co Laois, Ireland T: ROI T: NI E: hire@aggreko.ie Aggreko operates from more than 200 locations throughout the world. For the location nearest you please go to:

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES

SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES Electric, IDF, Gas & Oil Fired Technology Heating Capacity 2.0-2,000kW ICS Cool Energy Hire Division The hire division of ICS Cool Energy is your

More information

ThermoSorb Desiccant Dryers

ThermoSorb Desiccant Dryers ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

MovinCool Office Pro Series. The Portable Spot Cooling Solution

MovinCool Office Pro Series. The Portable Spot Cooling Solution MovinCool Office Pro Series The Portable Spot Cooling Solution The Office Pro 2002 American Standard Inc. All rights reserved Losing Is Not An Option With The Office Pro Series. The loss of data and equipment

More information

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same

More information

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Cooling Small Server Rooms Can Be Inexpensive, Efficient and Easy - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Server Rooms Description & Heat Problem Trends

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

Natural geothermal energy.

Natural geothermal energy. ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

FTXS. Wall Mount Heat Pump or Cooling Only

FTXS. Wall Mount Heat Pump or Cooling Only FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

Temperature control solutions to help you improve business performance

Temperature control solutions to help you improve business performance Temperature control solutions to help you improve business performance Our aim is to help businesses enhance their performance by using portable and modular process cooling and HVAC methods to overcome

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT UP TO 15 SEER Performance MINI-SPLIT SYSTEM UNITS AIR CONDITIONING AND HEAT PUMPS COMPLETE ROOM COMFORT WITH EASY-TO-USE REMOTE CONTROL HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT The Goodman brand offers

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

ECO-AIR AIR CONDITIONING www.northamericanhvac.com

ECO-AIR AIR CONDITIONING www.northamericanhvac.com INDEX ACCESSORIES INSTALLATION... 3-7 LINE SETS... 3-7 GEOTHERMAL... 3-8 WIRING CABLE... 3-8 CIRCULATOR PUMPS (PRO-TECH MODEL)... 3-9 DC INVERTER SINGLE ZONE HEAT PUMP... 3-6 DC INVERTER TECHNOLOGY...

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects

Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects 4.02.08 updated Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects Moisture Removal Systems www.groundheaters.com www.wackerneuson.com Controlling moisture

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL Drawing : - TPC337 Issue : - 2 Date : - 24/01/12 UNPACKING Thank you for deciding to purchase an EIPL Industrial dehumidifier. Like the many tens of thousands

More information

Guidelines for Preparing for a Temporary Steam Plant

Guidelines for Preparing for a Temporary Steam Plant Guidelines for Preparing for a Temporary Steam Plant Trailer-Mounted Boilers Skid Mounted Boilers Mobile Boiler Rooms Mobile Feedwater Vans Mobile Steam Plants Emergency Preparedness Plan Table of Contents

More information

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

Installation Questions

Installation Questions Installation Questions How do I determine what type of heat I have? There may be several ways to determine what type of heat you have. First, if you can access the unit that is responsible for creating

More information

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hot Water. Heat pump water heaters. Residential and Commercial R410a Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating

More information

Direct Fresh Air Free Cooling of Data Centres

Direct Fresh Air Free Cooling of Data Centres White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

ROTEX gas hybrid heat pump. A strong team.

ROTEX gas hybrid heat pump. A strong team. ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you! CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different

More information

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. AFFORDABLE SOLUTIONS FROM AMERISTAR. We know that heating and cooling systems can be a major investment for homeowners. Our goal is

More information

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53% 1 1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53% 2. How much money do commercial facilities spend per square foot on energy costs

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com

More information

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,

More information

IV. Rear Mount System

IV. Rear Mount System Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

Low Cost. Lower Energy Costs. Higher Efficiency.

Low Cost. Lower Energy Costs. Higher Efficiency. HI-E DRY dehumidifiers remove two to three times more water per kilowatt hour of electricity than conventional dehumidifiers. Low Cost. Lower Energy Costs. Higher Efficiency. Therma-Stor designed an efficient,

More information

Refrigerated Air Dryers. Catalogue

Refrigerated Air Dryers. Catalogue Refrigerated Air Dryers Catalogue GB Why use a refrigerated dryer? Humidity is a component of atmospheric air, which can be found in the compressed air distribution systems and the machines that use the

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

ENHANCED LABORATORY HVAC SYSTEM

ENHANCED LABORATORY HVAC SYSTEM ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of

More information

The Complete Air Conditioning Guide

The Complete Air Conditioning Guide 1 The Complete Air Conditioning Guide Everything you need to know for total peace of mind when considering the installation of portable or fixed air conditioning call us free on 0800 0828001 or visit us

More information

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires

More information

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System TECHNICAL SPECIFICATION StirLIN-1 Economy Liquid Nitrogen System Reference 80 8120_01 Issue Date August 1, 2015 1. INTRODUCTION Since more than sixty years Stirling Cryogenics has designed and manufactured

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION

More information

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems Fundamental Principles of Environmentally Responsible, Energy Efficient Buildings 1. Energy efficiency is

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

Compressed air systems. How to plan, install and operate. Best Practices for Maintenance Management

Compressed air systems. How to plan, install and operate. Best Practices for Maintenance Management electronically REPRINTED FROM APRIL 2013 Best Practices for Maintenance Management If a shop builds and operates its compressed air system to avoid common problems including inadequate flow, leaks and

More information

Air-Conditioning Buying Guide

Air-Conditioning Buying Guide Air-Conditioning Buying Guide Buying a new air-conditioning system is a big decision. This Air-Conditioning Buying Guide can help you make the right choice, save energy and money. Shop with confidence

More information

Printing and Publishing Energy Savings Guide

Printing and Publishing Energy Savings Guide Printing and Publishing Energy Savings Guide Oregon printing and publishing plants face challenges of rising operating costs, environmental and other regulations, outdated equipment and customer demand

More information

How To Buy A Lennox Power System

How To Buy A Lennox Power System HVAC for Schools A Comprehensive Look at Products for a Clean, Comfortable Learning Environment Why Schools Choose Lennox Even as resources for schools continue to be constrained, education leaders and

More information

Technical Specification. Generating Set with Waukesha engine burning natural gas

Technical Specification. Generating Set with Waukesha engine burning natural gas Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

The natural ombination

The natural ombination The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

Drives and motors. A guide to using variable-speed drives and motors in retail environments

Drives and motors. A guide to using variable-speed drives and motors in retail environments Drives and motors A guide to using variable-speed drives and motors in retail environments Improving energy efficiency and lowering the carbon footprint Retailers across the UK take their corporate responsibility

More information

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 Wallet card photocopy Inspection Authority: Signature: Date: / / Submitted For: ( Owner ) Name Address City Prov Postal code Phone ( ) Fax ( ) Designer/Signature:

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED High Efficiency Condensing Boilers Proven Reliability, American-Made Home Heating Comfort. Look for this logo throughout this literature to see the unique features that set U.S. Boiler Company apart from

More information

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/ CW-5000/ 5200 Contents Cautions ---------------------------------------------------------------- 3 Parts introduction --------------------------------------------------- 4 Installation ------------------------------------------------------------

More information

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard Duplexvent DV72 EC MVHR is designed to provide constant volume ventilation levels to exceed the latest Building Regulations 2010. The

More information

Evaluate, Clean, and Tune Guidance

Evaluate, Clean, and Tune Guidance Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system

More information

Energy Efficiency. Energy Efficient Home Cooling:

Energy Efficiency. Energy Efficient Home Cooling: Energy Efficiency Energy Efficient Home Cooling: Choosing an air conditioning system is an important decision. A poor choice may be costly to purchase and operate and yet fail to provide the desired cooling

More information

Glossary of HVAC Terms

Glossary of HVAC Terms Glossary of HVAC Terms Heating, Ventilation and Air Conditioning (HVAC) is a major sub- discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

GLOBACON 05 HVAC Systems for Cogen

GLOBACON 05 HVAC Systems for Cogen GLOBACON 05 HVAC Systems for Cogen Track 2, Session 2B Advanced HVAC and Building Systems Date: March 24th, 2005 Gearoid Foley President Integrated CHP Systems Corp. Integrated CHP Systems Corp. Electricity

More information

Dehumidifier D 850E. - Instruction manual version 02

Dehumidifier D 850E. - Instruction manual version 02 Dehumidifier D 850E - Instruction manual version 02 Content 1. Description of dehumidifier 1.1. General data 1.2. Technical data 2. Operation and usage 2.1. Usage 2.2. Location and installation 2.3. Preparing

More information

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO. Upflow/ Horizontal Left, Downflow/ Horizontal Right Speed Two Stage Condensing Gas-Fired Furnace XV 95 TUH2B060A9V3VB TUH2B080A9V3VB TUH2B080A9V4VB TUH2C100A9V4VB TUH2C100A9V5VB TUH2D120A9V5VB Direct Vent

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump your comfort. our world. Daikin Altherma Hybrid Heat Pump The natural combination Heating Integrated Solutions Ventilation Air Conditioning Refrigeration About Daikin Forward thinking... Daikin has a worldwide

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477

More information

IMMERSION MANAGEMENT SERVICE KG

IMMERSION MANAGEMENT SERVICE KG IMMERSION MANAGEMENT SERVICE KG German Based Engineering and Consulting Group developing and implementing High Efficiency HVAC Solutions for Green Buildings Innovative Water Saving Technologies IMMERSION

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

clean and quiet dental

clean and quiet dental clean and quiet dental clean air for your dental clinic JUN-AIR introduced the first compressor almost 50 years ago and started the development of the technology and design, which has made JUN-AIR compressors

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

Creating Efficient HVAC Systems

Creating Efficient HVAC Systems Creating Efficient HVAC Systems Heating and Cooling Fundamentals for Commercial Buildings Heating, ventilating, and air conditioning (HVAC) systems account for nearly half of the energy used in a typical

More information

Operation and Installation Manual. Max Series

Operation and Installation Manual. Max Series Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information