1 Page /5 universal regulator for application in solar- and heating systems function control plastic housing with easy mounting and compact dimensions text display with menu control by rotary knob relay outputs for pump speed bus connection for remote data displays, data logger and computer Technical data DeltaS eltasol ol Pro Housing: plug-in plastic housing Size: 50 x 0 x 5 mm Protection type: IP30 / DI Display: 4-digit plain text display Breakover points: adjustable by the menu Control range: C Ambient temperature: C Adjustments: system choice and menudriven Inputs: 3 sensor inputs Pt000 This innovative electronic solar regulator RESOL D is the central element in the efficient operation of solar thermal and heating systems. DeltaS The regulator RESOL DeltaS eltasol ol Pro is programmed with different basic systems for universal application in solar- and heating systems; individual programmes may be selected by the user as necessary. Additional programmes may optionally be added to enable optimum control of the system. In designing this regulator great importance has been attached to enclosing the essential components. The central element is the rotary knob with integrated pushbutton. In combination with a 4-place display, the user is allowed to access system menus and change control parameters within set limits. This simple concept gives the user the confidence to use the regulator without affecting any of the essential operational functions. This version of the regulator is additionally equipped with the RESOL V-BUS for connection of additional modules such as remote data display, data logger, PC-adapter as well as a calorimeter and a RS3-interface for direct data output to a PC. The regulator DeltaSol PRO is also available as an individual OEM-version, so that additional adaptations to the system are possible. (to be continued next page) o responsibility can be accepted for any errors or technical changes. RESOL 96 DeltaSolpro_montage.p65 deltapro_montage.p65

2 for solar- and heating systemes Page /5 (continued from page ) Outputs: relay outputs for pump speed, total power supply x 4 A Power supply: 30 V AC, ± 0 % Power consumption: max. 4 VA Data output: RESOL V-BUS Examples DeltaS eltasol ol Pro The above-shown icons should only be used for illustration; they only represent a choice of the possible applications. Order indication Article-no. RESOL DeltaS eltasol ol Pro RESOL DeltaS eltasol ol Pro - complete package - incl. 3 temperature sensors Pt000 ( x FKP6, x FRP6) Patch cord / software Connecting cable with special plug and 9-contact connection plug for the serial PC-interface as well as evaluation software DeltaSol PC Accessory: Overvoltage protection It is highly recommended to connect this RESOL overvoltage protection SP to all collector sensors in order to avoid overvoltages (e.g. by lightening). Order indication RESOL SP Article-no.:

3 Page 3/5 Safety regulations: Please read the following information carefully before installing and operating the regulator. In this way damage to the regulator or the solar system will be avoided. All electrical wiring must comply with the latest IEE regualtions.. Mounting Warning: Switch of power supply before opening the housing!. Mounting at the wall 3 4 Please unlock both snap connections () at the top and at the bottom of the housing by means of a pointed item. The housing () can now be removed from the base (3). The required openings and cable feed-throughs (4) must be broken through and deburred. The positions for the 4 fastening screws (5) must be marked and the base may be attached by means of the enclosed screws and dowels. The electrical connection can be effected now. The unit must only be located internally. It is not suitable for installation in hazardous locations and should not be sited near to any electromagnetic fields. 5. Electrical connection The power supply to the regulator must only be made by an external power supply switch (last step of mounting!) and the line voltage must be 30 Volt ± 0 % ( Hz). Pumps, valves,... can be connected to the consumeroutputs R and R of the terminals at the base: = conductor R 4 = conductor R, 3 = neutral conductor ground clamp = protective earth conductor The power supply is effected at the terminals: 5 = neutral conductor 6 = conductor L ground clamp = protective earth clamp The temperature sensors (S up to S3) will be connected to the following terminals independently of the polarity : / = temperature sensor S 3 / 4 = temperature sensor S 5 / 6 = additional sensor S3, as for measurement purposes or for additional functions (e.g. further stores)

4 for solar- and heating systemes Page 4/5 The regulator RESOL D is equipped with a RESOL V-BUS-connection for data transmission and energy supply (terminals 7 and 8, marking of connection BUS at the base-/ isolation plate). One or more RESOL V-Bus modules can be connected by this data bus: RESOL WMZ-M, calorimeter-module. RESOL DFA, temperature- and malfunction display for comfortable control of the most important measuring data at remote places. RESOL V-BUS (terminals 7 and 8) RESOL PC-adapter for transmission of the measuring data to a connected PC. Evaluation and visualisation occurs by the software DeltaSol PC. Further modules are in preparation. special plug jack, RS3 (in the upper part of the housingl) At the lower front of the regulator is a special plug jack for the second data output. A PC can be directly connected by RS3-interface to this data output. By means of the free evaluation tools DeltaSol PC, the values measured by the regulator can be read-out, processed and visualizased. The software enables a comfortable balance and function control of the system, but also an editing of the data records for a further processing in other application programmes. The evaluation tool DeltaSol PC can be downlaoded free of charge from the RESOL homepage in the Internet ( or can be directly ordered at RESOL-Elektronische Regelungen GmbH together with a patch cord (see page ). ou will find the location of the special plug jack imprinted on the base/isolation plate at the posititon marked with RS3. chinch plug interface adapter Sub-D connection cable PC, COM-port twisted -wire cable western plug Sub-D plug

5 Page 5/5 Precision-platin-temperature sensors Pt000 (FKP and FRP) are used for the RESOL DELTA Pro. The arrangement of the sensors is of great importance to the total efficiency of the regulator. The collector temperature should be measured in the upper part of the collector. In stores with own heat exchanger, the sensor must be directly mounted in the upper part of the heat exchanger. By using external heat exchangers, the sensor must be fixed at the bottom of the store. For individual operation systems, our product range contains 3 different types of sensors (sensors for installation in present immersion sleeves, flatscrew sensors or cylindrical clip-on sensors). The sensor types FK and FR have the same electrical features and are available in the same models, They only differ in the connecting cable: FK:,5 m weather- and temperature resistant silicone cable for temperatures between -50 C C, mostly used for collectors. FR:,5 m PVC cable for tempertures between -5 C C, mostly used for stores. Make sure that all electrical works are carried out according to the relevant local and IEE-regulations. The sensor cables carry low voltages and they must not run together in a cable conduit with cables carrying higher voltages than 50 Volt. By using longer cables or cable conduits, please use screened cables. The seensor cables can be lengthened up to 00 m, but the cross section must be,5 mm² (or 0,75 mm² up to a cable length of 50m); screened cables should be used preferably. The sensors must not get directly in contact with water, please use always immersion sleeves. Standard temperature sensors: for installation in present immersion sleeves (they are included in complete packages) FKP6 or FRP6: 6 mm, Pt000 Immersion sensors: available in different length (=immersion depth) FKP60: 60mm immersion depth, chromium-plated copper FKP50: 50mm immersion depth, chromium-plated copper Important: The sensors must be completely pushed into the sleeve and the nut must be slightly tightened. Cylindrical clip-on sensors: for any pipe diameter, cpl. with fastening collar FKP0 or FRP0 Ensure good thermal contact of the sensor with the pipework by cleaning the contact area and by applying heat conduction paste between sensor and pipe. In order to protect the sensor cable against outside temperature influences, it is recommended to insulate the pipe. Flatscrew sensors: for installation on flat surfaces FKP8 or FRP8 Ensure good thermal contact. Use conduction paste and insulate the sensors against outside temperature influences. FK... : collector sensor FR... : store sensor Indication: In order to avoid overvoltage damage at the collector (e.g. by lightening), it is highly recommendend to use the overvoltage protection RESOL SP.

6 for solar- and heating systemes Page 6/5 3. Operation: 3. Mode switch: The mode switch is positioned at the lower front side of the housing and enables the following adjustments: 0 relay switched-off Auto automatic operation for relay outputs I relays (R and R) switched-on, permanent operation 3.3 Control lamps: 3. Rotary knob with integrated pushbutton and the menu system Rotary knob with integrated pushbutton 3 light emitting diodes with the following symbols are located at the front side of the regulator: control lamp for relays red: relays (R and R) OFF green: relay (R or R) O control lamp for malfunctions flashing: error message control lamp for manual operation green: mode switch in position I (R and R O) red: relays (R and R) OFF The regulator RESOL D can only be operated by the rotary knob with integrated pushbutton. The main menu is shown on the display in the output condition. 5 menus can be selected in the MAI menu:. MEASURED VALUES. ADJUSTMETS 3. OPTIOS 4. BALACE VALUES 5. ERROR MESSAGE The plain text-display shows a 4-line section of the choosen menu. The flashing cursor shows the actual position within this menu. A small arrow symbol on the upper right side of the display indicates the possible scroll directions of the cursor. By turning the rotary knob, the cursor runs through the menu. By pushing the integrated pushbutton a menu item can be choosen. By turning the rotary knob again, the standard value can be changed. By pushing once more the pushbutton, the modification is finished. A maladjustment is avoided by a security inquiry check, which can be answered with ()es or ()o.

7 Page 7/5 4. Basic systems and menu 4. Basic systems The regulator RESOL D is programmed for 4 basic systems: System : collector and store System : collector and stores System 3: collectors and store System 4: swimming-pool system The basic systems can be adjusted to each system by activating or deactivating additional options in the menu. Please find a more detailed description of all possible systems in point 6 of this instruction. 4. Menu Indication: The selective adjusted values and options are system dependent and can only be found in the display if the they are available for the choosen basic system. By chosing BACK at the end of each menu, you will get back to the main menu. ou will find a menu structogram on page Main menu The following submenus are available in the main menu: Meas. values: Indication of actual sensor temperatures, relays status and time Adj. values: System selection and adjustment of control parameter or regulation default Options: Activation or deactivation of system dependent additional options Bal. values: Time- and temperature balances for regulation and system Error report: Failure report 4.. Measured values The measurement values menu offers the possibility to display the actual sensor temperatures for S up to S3, the relative on-period for relays and and for indication or adjustment of time: Sensor : present temperature at sensor in C Sensor : present temperature at sensor in C Sensor 3: present temperature at sensor 3 in C Relay : present relative on period for relay in % Relay : present relative on period for relay in % Time: Indication and adjustment of the actual time

8 for solar- and heating systemes Page 8/ Adjusted values A selection of the basic systems and the adjustment of the control parameter or the regulation default is to be made within the adjustment value menu: System: Selection of the basic systems min. rot. speed: Minimum rot. speed for relays output and min. runtime: Switch-off delay for relay Ton: Switch-on temperature difference for relay Toff: Switch-off temperature difference for relay Ton: Switch-on temperature difference for relay Toff: Switch-off temperature difference for relay Tmax store : Maximum temperature for store Tmax store : Maximum temperature for store Priority: Priority logic in systems with stores Pruntime: Pbreak: Therm on: Therm off: Therm on: Therm off: min TQ: Half wave: Minimum runtime of the solar pump for charge of the less important store Waiting time for control of the rise in temperature at the collector in case of priority logic Switch-on temperature for thermostat function Switch-off temperature for thermostat function Switch-on time for thermostat function Switch-off time for thermostat function Minimum temperature for the heat source Control value (please don t shift) 4..4 Options All available additional options can be activated or deactivated by replying ()es/()o in the option menu: Frost protection: As soon as the temperature falls under +4 C, warmer water from the store wil be pumped into the collector in order to avoid frost damages. If the temperature of +5 C is achieved at the solar panel, the pump switches off again. Indication: This function is only appropriate for countries with few days of temperatures at freezing point. Sp-protection:The store can indeed be charged up by the collector cooling function above the adjusted maximum temperature, but not exceeding 90 C. Tube col.: Recooling: Switch-on logic for improvement of the turn-on characteristics of systems with unfavourable placed collector sensors - prevents a belated switching-on of the system. The collector circuit is switched on every 30 min. for a period of 30 sec. If the maximum store temperature is exceeded, the solar pump is switched on for cooling purposes in order to avoid an overheating of the collector. The temperature of the store can rise, but only up to 90 C (security switch-off of the store). Collector cool.:if the collector temperature rises above the adjusted maximum collector temperature (0 C), the pump remains activated until this temperature limit value is again underrun. Bypass: The bypass valve is switched on if the temperature difference between bypass sensor and store sensor is higher than Ton. It is again switched off if this difference is lower than Toff. Thermos. R: Use of relay output for the thermostat function (cooling- or heating function). T R: Valve: Tmin: Additional temperature difference regulation for relay output Deactivation of the pump speed regulation for relay output Minimum temperature of the heat source

9 Page 9/ Balance values 4..6 Error report Operation: Pump : Pump : min S: max S: min S: max S: Operating days of the regulator.. Operating hours of the consumer connected to relay. Operating hours of the consumer connected to relay. Lowest temperature measured at temperature sensor S. Highest temperature measured at temperature sensor S. Lowest temperature measured at temperature sensor S. Highest temperature measured at temperature sensor S. Short circuit: Line break: EEPROM: RTC Error: Code deletion: Interruption of the sensor lead with indication of the concerned temperature sensor. Interruption of the sensor lead with indication of the concerned temperature sensor. Error in memory chip. Modifications will not be saved in case of a power failure. Error in real-time clock. Time control of the thermostat function is not guaranteed. Reset status of error messages. min S3: Lowest temperature measured at temperature sensor S3. max S3: Highest temperature measured at temperature sensor S3. 5. Commissioning. Mounting of the housing The upper part of the housing must be plugged on the socket. The ac power supply is effected by an external switch. Warning: The snap connections of the housing must clearly lock.. Switching: The mode switch of the regulator must be set to 0 before the power connection can be switched on. After an initialisation phase of 5 seconds, the control lamps illuminate and red for indication of the mode switch position. 3. Adjustments: Please adjust now the respective basic system, the required options and the necessary regulation defaults. Before finishing, please check all adjustments. 4. Test starting of the system and automatic operation If the switch is set to I, the control lamps illuminate and green in order to indicate the mode switch position and the consumer connected to terminals to 4 are supplied with power. After having finished this test, the mode switch is to be switched to Auto for the automatic operation.

10 for solar- and heating systemes Page 0/5 5. Menu

11 Page /5 6. Examples 6. System, solar system with collector and store: 4 5 The regulator () determines the temperature difference between collector sensor S () and store sensor S (3). As soon as this difference is higher or identical to the adjusted temperature difference ( Ton), the pump (4) is activated so that the store is loaded until the switch-off temperature difference ( Toff) or the maximum store temperature are reached. The 3. temperature sensor S3 (5) can additionally be used for measuring purposes (e.g. for measuring the temperature in the upper part of the store). 3 menu point factory setting selected adjustments adjusted values / system adjusted values / min rot. speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Tmax st 60 C options / frost protection options / store-protection options / tube col. options / recooling options / collector cooling options / bypass options / thermostat R options / T R options / Tmin

12 for solar- and heating systemes Page /5 6. System, solar system with collector, store and after-heating: The regulator () determines the temperature difference between collector sensor S () and store sensor S (3). As soon as the difference is higher or identical to the adjusted switch-on temperature difference ( Ton), the pump (4) is activated so that the store is loaded until the switch-off temperature difference ( Toff) or the maximum store temperature are reached. The 3. temperature sensor S3 (6) is used for measurement of the temperature in the upper part of the store. A recharge of the hot domestic water is possible by the option thermostat function. menu point factory setting selected adjustments adjusted values / system options / thermostat R adjusted values / min rot. speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Tmax store 60 C adjusted values / therm on 0.0 C 40 C adjusted values / therm off 0.0 C 45 C adjusted values / therm on(time) 0:00 adjusted values / therm off(time) 0:00 options / frost protection options / store-protection options / tube col. options / recooling options / collector cooling options / bypass options / T R options / Tmin

13 Page 3/5 6.3 System, reverse raising of a heating circuit by solid fuel boiler or boiler inserted in stove: 4 3 The regulator () determines the temperature difference between the measuring sensor of the solid fuel boiler or boiler inserted in stove S () and the temperature sensor S (3) of the return flow. If this measured temperature difference is higher or identical to the adjusted value Ton, the return flow temperature is increased by using the heat of the solid fuel boiler in case of activating a 3-way-valve (4) (heating support). It is simultaneously controlled, if a given minimum temperature is reached or exceeded in order to avoid flue gas condensation. menu point factory setting selected adjustments adjusted values / system options / Tmin adjusted values / min rot. speed adjusted values / Ton adjusted values / Toff adjusted values / Tmax store(return flow) 30 % 60 C adjusted values / min TQ 0.0 C 60 C (recommended) options / frost protection options / store-protection options / tube col. options / recooling options / collector cooling options / bypass options / thermostat options / T R

14 for solar- and heating systemes Page 4/5 6.4 System, store loading by solid fuel boiler: The regulator () determines the temperature T at the sensor S () of the solid fuel boiler- or boiler inserted in stove with the temperature T at the sensor S (3) of the store. If the measured temperature difference is higher or identical to the adjusted value Ton, the pump (4) is activated if the adjusted minimum temperature is at the same time reached or exceeded (avoidance of flue gas condensation).the store is only loaded up until the adjusted maximum temperature. The 3. temperature sensor S3 (5) can be used for measuring purposes (e. g. for measurement of the temperature in the upper part of the store). menu point factory setting selected adjustment adjusted values / system options / Tmin adjusted values / min rot.speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Tmax st 60 C adjusted values / min TQ 0.0 C 60 C (recommended) options / frost protection options / store protection options / tube collectors options / recooling options / collector cooling options / bypass options / thermostat options / T R

15 Page 5/5 6.5 System, solar system with collector cooling function for use of surplus energy: The regulator () determines the temperature difference between the collector sensor S () and the store sensor S (3). As soon as the difference is higher or identical to the adjusted switch-on temperature difference ( Ton), the pump (4) is activated so that the store is loaded until the swich-off temperature difference ( Toff) is reached. If the maximum temperature of the store is reached (Tmax Sp), the pump of the solar circuit (4) is switched off and the pump of the cooling circuit (5) is activated so that the surplus energy is carried off. The 3. temperature sensor S3 (6) can be additionally used for measuring purposes (e.g. for measurment of the temperature in the upper part of the store). menu point factory setting selected adjustment adjusted values / system adjusted values / min rot.speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Tmax st 60 C options / frost protection options / store protection options / tube collectors options / recooling options / collector cooling options / bypass options / thermostat options / T R options / Tmin

16 for solar- and heating systemes Page 6/5 6.6 System, solar system with recooling function for use of surplus energy: The regulator () determines the temperature difference between the collector sensor S () and the store sensor S (3). As soon as the difference is higher or identical to the adjusted switch-on temperature difference ( Ton), the pump (4) is activated and the store is loaded until the switch-off temperature difference ( Toff) is reached. If the maximum store temperature (Tmax Sp) is reached, the pump of the solar circuit (4) remains activated. The pump of the cooling circuit (5) is additionally activated in order to carry off the surplus energy. The 3. temperature sensor S3 (6) can be additionally used for measuring purposes (e.g. for measuring the temperature in the upper part of the store). menu point factory setting selected adjustment adjusted values / system adjusted values / min rot. speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Tmax st 60 C options / frost protection options / store-protection options / tube coll. options / recooling options / collector cooling options / bypass options / thermostat options / T R options / Tmin

17 Page 7/5 6.7 System, solar system with thermostat function for use of surplus energy: The regulator () determines the temperature difference between collector sensor S () and store sensor S (3). As soon as the difference is higher or identical to the adjusted switch-on temperature difference ( Ton), the pump (4) is activated and the store is loaded until the temperature difference ( Toff) is reached.if the maximum store temperature (Tmax Sp) is reached, the pump of the solar circuit (4) is switched off. The 3. temperature sensor S3 (6) is used for temperature measurement in the upper part of the store and by optionally activating the thermostat function, the pump of the cooling circuit is switched on so that the surplus energy is carried off. menu point factory setting selected adjustments adjusted values / system options / thermostat R adjusted values / min rot. speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Tmax st 60 C adjusted values / therm on 0.0 C adjusted values / therm off 0.0 C adjusted values / therm on(time) 0:00 adjusted values / therm off(time) 0:00 options / frost protection options / store-protection options / tube col. options / recooling options / collector cooling options / bypass options / T R options / Tmin

18 for solar- and heating systemes Page 8/5 6.8 System, solar system with external heat exchanger: The regulator () determines the temperature difference between collector sensor S () and store sensor S (3). As soon as the difference is higher or identical to the adjusted switch-on temperature difference ( Ton), the pump (4) is activated; the primary circuit is heated up. The temperature difference between S3 (5) and S (3) is simultaneously determined in comparasison with the. adjustable switchon temperature difference ( Ton). If this temperature difference is higher than the adjusted value, the pump (6) is switched on by relay and the store is loaded. 3 menu point factory setting selected adjustment adjusted values / system options / bypass adjusted values / min rot. speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Ton adjusted values / Toff adjusted values / Tmax st 60 C options / frost protection options / store-protection options / tube col. options / recooling options / collector cooling options / thermostat R options / T R options / valve options / Tmin

19 Page 9/5 6.9 System, solar system with bypass: The regulator () determines the temperature difference between collector sensor S () and store sensor S (3). As soon as the difference is higher or identical to the adjusted switch-on temperature difference ( Ton), the pump (4) is activated and the primary circuit is heated up. The temperature difference between S3 (5) and S (3) is at the same time determined in comparison with the. adjustable switch-on temperature difference ( Ton). If this temperature difference is higher than the adjusted value, the valve (6) is switched on by relay and the store is loaded. 3 menu point factory setting selected adjustment adjusted value / system options / bypass options / valve adjusted value / min rot. speed 30 % adjusted value / Ton adjusted value / Toff adjusted value / Ton adjusted value / Toff adjusted value / Tmax store 60 C options / frost protection options / store-protection options / tube collectors options / recooling options / collector cooling options / thermostat R options / T R options / Tmin

20 for solar- and heating systemes Page 0/5 6.0 System, solar system with stores (pump control): 5 6 The regulator () compares the temperature at the temperature sensor S () with the temperatures at S (3) and S3 (4). If the measured temperature differences are higher than the adjusted switch-on temperature differences Ton or Ton, the respective pump (5/6) is activated and the affiliated store is only loaded up until the adjusted maximum temperature. Priority can optionally be given to one store. 3 4 If no store is prefered, both stores are independently loaded up until their maximum temperatures are reached (parallel loading). menu point factory setting selected adjustments adjusted values / system adjusted values / min rot. speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Ton adjusted values / Toff adjusted values / Tmax store 60 C adjusted values / Tmax store 60 C adjusted values / priority adjusted values / Prun 5 min adjusted values / Pbreak min options / frost protection options / store-protection options / tube collectors options / recooling options / collector cooling. options / valvel

21 Page /5 6. System, solar system with stores (valve control): 5 6 The regulator () compares the temperature at the temperature sensor S () with the temperatures at S (3) and S3 (4). If the measured temperature differences are higher than the adjusted switch-on temperature differences Ton or Ton, the pump (5) is activated and by the valve (6) and the respective store is only loaded up until the adjusted maximum temperature is reached. By using this system, priority must be given to one of the stores, because parallel loading is not possible. 3 4 menu point factory setting selected adjustments adjusted values / system options / valve adjusted values / min rot. speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Ton adjusted values / Toff adjusted values / Tmax store 60 C adjusted values / Tmax store 60 C adjusted values / priority adjusted values / Prun 5 min adjusted values / Pbreak min options / frost protection options / store-protection options / tube collectors options / recooling options / collector cooling

22 for solar- and heating systemes Page /5 6. System, solar system with store charge in layers: The regulator () compares the temperature at the temperature sensor S () with the temperatures at S (3) and S3 (4). If the measured temperature differences are higher than the adjusted switch-on temperature differences Ton or Ton, the pump (5) is activated and the respective store is loaded up by the valve (6) until the adjusted maximum store temperature is reached. The adjusted priority logic causes a priority charge of the upper part of the store. 3 menu point factory setting selected adjustments adjusted values / system options / valve adjusted values / min rot. speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Ton adjusted values / Toff adjusted values / Tmax store 60 C adjusted values / Tmax store 60 C adjusted values / priority adjusted values / Prun 5 min adjusted values / Pbreak min options / frost protection options / store-protection options / tube collectors options / recooling options / collector cooling

23 Page 3/5 6.3 System 3, solar system with east-/west collectors: The regulator () compares the temperatures at both collector sensors S () and S (3) with the store temperature at temperature sensor S3 (4). If one of the measured temperature differences is higher than the adjusted switch-on temperature differences Ton and Ton, the respective pump (5/6) is switched on and the store is loaded. 4 menu point factory setting selected adjustments adjusted values / system 3 adjusted values / min rot. speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Ton adjusted values / Toff adjusted values / Tmax store 60 C options / frost protection options / store-protection options / tube collectors options / recooling options / collector cooling options / Tmin

24 for solar- and heating systemes Page 4/5 6.5 System 3, solar system with collector, combination store and solid fuel boiler: menu point factory setting selected adjustments adjusted values / system 3 options / Tmin adjusted values / min rot. speed 30 % adjusted values / Ton adjusted values / Toff adjusted values / Ton adjusted values / Toff adjusted values / Tmax store 60 C adjusted values / min TQ (only for solid fuel boiler) 0.0 C options / frost protection 60 C (recommended) options / store-protection options / tube collectors options / recooling options / collector cooling

25 Page 5/5 7. Test aid: Pt000-sensor Please check the following items if the regulator RESOL DeltaS does not work faultlessly :. Power supply The power supply is guaranteed if at least one control lamp lights up.. Error report If there is a malfunction in the regulation circuit, the malfunction lamp lights up. By chosing the menu point ERROR REPORT you will get into the submenu, in which a more detailed error description is indicated: Short-circuit: Interruption of the sensor lead with indication of the concerned temperature sensor. The error code is indicated for this sensor in the measurement result menu. Line break: EEPROM: Interruption of the sensor lead with indication of the concerned temperature sensor. The error code is indicated for this sensor in the measurement result menu. Error in memory chip.modifications will not be saved in case of power failure. T > 5. K: Plausibility check, temperature difference is higher than 5, K; regulation function is guaranteed but the system must be checked for defect elements (pump, valves etc.). Delete the code: Reset status of error messages. 3. Relay Please check the fuses, if the solar pump is not activated by the regulator in spite of an existing line voltage and mode switch position to I. The relay output of the regulator is protected by can fuses T4 A which are accessible on the base/isolation plate after removing the housing and can be changed now (spare fuses are enclosed).

RESOL DELTA Sol. universal temperature differential. regulator for solar- and heating systems Mounting instructions. page 1/11

RESOL DELTA Sol. universal temperature differential. regulator for solar- and heating systems Mounting instructions. page 1/11 page 1/11 universal temperature differential regulator for applicati in solar- and heating systems plastic housing with easy mounting and compact dimensis digital display temperature user-friendly handling

More information

RESOL DeltaSol A. Mounting Connection Operation Examples. Manual

RESOL DeltaSol A. Mounting Connection Operation Examples. Manual RESOL DeltaSol A Mounting Connection Operation Examples www.resol.dedeltasol A Manual Thanks for buying a RESOL controller. Read this manual carefully to get the best performance from this unit. Contents

More information

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

Split Controller. User Manual SM-SS-F 2009/01/04

Split Controller. User Manual SM-SS-F 2009/01/04 Split Controller SM-SS-F User Manual 2009/01/04 Table of contents 1. Parts illustration.... 1 2. Electrical technical data...... 2 3. Electrical connection...3 4. Assemble parts...4 4.1 Assemble the fixed

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy

More information

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS.  Construction Automotive Industry DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

1. Safety information

1. Safety information ---- Contents 1. Safety information... 4 1.1 Installation and commissioning... 4 1.2 About this manual... 4 1.3 Liability waiver... 4 1.4 Important remark... 5 1.5 Description of symbols... 5 1.6 Description

More information

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260 THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260 STANDARD THERMOSTAT KIT 1.0 KIT CONTENTS Parts included: 1 x Thermostat 1 x Wall plate 2 x Mounting box screws 1 x Floor temperature

More information

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation. Data logger Installation and operating instructions SOREL Connect Read carefully before installation, commissioning and operation 1.1. - Specifications Description of data logger Electrical specifications:

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

Wireless 7 Day Programmable Room Thermostat

Wireless 7 Day Programmable Room Thermostat Wireless 7 Day Programmable Room Thermostat Cat. No. TRT037 Transmitter Receiver Operating & Installation Instructions What is a programmable room thermostat? an explanation for householders A programmable

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

PD 100A. Printing data system

PD 100A. Printing data system PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep

More information

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL 148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

More information

Doc. No: 412-121033 Issue: 1 Date: Aug 2014. BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02

Doc. No: 412-121033 Issue: 1 Date: Aug 2014. BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02 Date: Aug 2014 THERMAL TRANSFER CARD PRINTER BTT-02 TABLE OF CONTENTS Introduction... 3 System Contents and Initial Checks... 3 Installation... 4 Preparation of Installation Site... 4 Printer Connections...

More information

Installation and User Guide

Installation and User Guide Installation and User Guide 458-UNI8 8-Channel Universal Dimmer Module Introduction The 458/UNI8 is an 8-channel universal, digital transistor, dimmer module. Each channel s mode can be selected for either

More information

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

RVR Hybrid System Installer Instructions - 10052012. RVR Hybrid System Controller Installation Instructions

RVR Hybrid System Installer Instructions - 10052012. RVR Hybrid System Controller Installation Instructions RVR Hybrid System Controller Installation Instructions 1 Introduction to Hybrid Systems The RVR Hybrid system uses a combination of the Immergas Audax range of heat pumps with gas or oil boilers to create

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

GENERAL SUPPLEMENT 410. Radiantec CONTROLS FOR RADIANT HEATING CONTROLS PURPOSE OF RADIANTEC CONTROLS

GENERAL SUPPLEMENT 410. Radiantec CONTROLS FOR RADIANT HEATING CONTROLS PURPOSE OF RADIANTEC CONTROLS Radiantec ONTROLS FOR RADIANT HEATING GENERAL SUPPLEMENT 410 ONTROLS This supplement presents a layman s language narrative about Radiantec ompany controls, their design and their installation. This supplement

More information

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser FITTING AND OPERATING INSTRUCTIONS FOR DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM General information is given in the users instruction leaflet despatched with the appliance and/or on

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:

More information

Smile. The All-In-One Heating Controller

Smile. The All-In-One Heating Controller Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from

More information

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

B/S/H/ Error codes and service programmes PH

B/S/H/ Error codes and service programmes PH 1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E

More information

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1 Visage Digital Digital diverter TM Installation guide Visage Digital diverter installation instructions Page 1 Visage Digital diverter Visage Digital concealed with adjustable and fixed head Visage Digital

More information

4-Channel Thermometer / Datalogger

4-Channel Thermometer / Datalogger USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter

More information

SYSTEM 4C. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25

More information

TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel

TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel Installation and User Guide TYXIA Wireless receiver TYXIA RF 642-1 channel DELTA DORE Bonnemain - 35270 COMBOURG - France E-mail : deltadore@deltadore.com Unit compliant with the requirements of directives:

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Regulators. Heat pumps. Qualified technician NIBE TM AP-CS2.0. Operating Instructions UK

Regulators. Heat pumps. Qualified technician NIBE TM AP-CS2.0. Operating Instructions UK Operating Instructions UK Heat pumps Regulators Qualified technician NIBE TM AP-CS2.0 We reserve the right to make technical changes. 83052306bUK Translation of the operating manual Please read first This

More information

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases

More information

Heating Controller. Building Technologies HVAC Products

Heating Controller. Building Technologies HVAC Products 2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or

More information

BUSINESS. Elektronisches Türschloss. Installation and User Manual. www.burg-waechter.de. Ingeniously safe. Ingeniously simple.

BUSINESS. Elektronisches Türschloss. Installation and User Manual. www.burg-waechter.de. Ingeniously safe. Ingeniously simple. Elektronisches Türschloss BUSINESS Set 5011 PINCODE Set 5012 FINGERSCAN Set 5013 E-KEY Ingeniously safe. Ingeniously simple. BA/MA TSE Set 5000 dp/fsc 04/2012 Installation and User Manual BURG-WÄCHTER

More information

Installation & User Instructions

Installation & User Instructions 103 electro-mechanical 24 hour timeswitch for controlling hot water and heating Installation & User Instructions including Factory Replacement Units (FRU) Certification Mark This product complies with

More information

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting. Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

GL-235 Solar Pool Controller

GL-235 Solar Pool Controller GL-235 Solar Pool Controller Installation & Operation Manual G LDLINE CON TROLS www.goldlinecontrols.com Description The GL-235 is a differential temperature control for solar heating of pools, spas, and

More information

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Use A Power Supply On A Powerline 2.2 (Ai) KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings. 1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The

More information

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

DKG 972 Gas Burner Safety Control

DKG 972 Gas Burner Safety Control A Honeywell Company Gas Burner Safety Control For 2-stage atmospheric gas burners Flame detection: - Ionisation probe - Infrared-flicker detector IRD 1020.1 - UV flame sensor UVD 971 EN1C-0127SZ20 R0305

More information

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options. MX MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest

More information

Installation and Service Instructions for use by heating contractor SM1 SOLAR CONTROL MODULE IMPORTANT

Installation and Service Instructions for use by heating contractor SM1 SOLAR CONTROL MODULE IMPORTANT Installation and Service Instructions for use by heating contractor Solar Control Module for solar connections to the Vitotronic control SM1 SOLAR CONTROL MODULE Product may not be exactly as shown IMPORTANT

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Installation Guide. DEVIreg 530. Electronic Thermostat. www.devi.com

Installation Guide. DEVIreg 530. Electronic Thermostat. www.devi.com Installation Guide DEVIreg 530 Electronic Thermostat www.devi.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5

More information

SYSTEM 45. C R H Electronics Design

SYSTEM 45. C R H Electronics Design SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25

More information

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1

More information

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Applied Electronics. Commercial Dimming System UPDATE NOTICE REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with

More information

Install the DeviceNet Module using the following procedure:

Install the DeviceNet Module using the following procedure: Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from

More information

DS 1.102 DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

DS 1.102 DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches DS 1.102 02/99 AIR ROOM TEMPERATURE SENSOR with fan speed control switches Specification No. 528-X-XXX* The Active Room Temperature sensor incorporating fan speed control switches is designed to give a

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant GeyserWise TSE thermostat instruction manual SANS 181 compliant Before operating and installation, carefully read all instructions. Do not discard this manual. Index Warranty Components About the GeyserWise

More information

Description of functions

Description of functions Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the

More information

Operating instructions IV / 2007

Operating instructions IV / 2007 General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation

More information

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options. MANUAL CONGRATULATIONS on the purchase of your new professional switch mode battery charger and tester. This charger and tester is included in a series of professional chargers from CTEK Sweden AB and

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

User's Instructions. Alpha HE CB25/33 and HE SY25

User's Instructions. Alpha HE CB25/33 and HE SY25 User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:

More information

Model 53603. Owner s Manual. Español - P. 19 Français - P. 39

Model 53603. Owner s Manual. Español - P. 19 Français - P. 39 Model 53603 Owner s Manual Español - P. 19 Français - P. 39 Table of Contents I. Introduction............................ 1 Sample Watering Plan.......................... 1 II. Installation...........................

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC HOJA TÉCNICA 1400H101 Edición 01 (02 de 08) www.ako.es GENERAL TECHNICAL SPECIFICATIONS Temperature range: -50ºC to +99ºC type: NTC Total accuracy ( + controller): ±1ºC lead extension with cable AKO-15586:

More information

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program. MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest

More information

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2 Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2 Heatmiser UK td Tel: +44(0)1254 776343 Primrose House www.heatmiser.co.uk Primrose Street Darwen ancashire BB3 2DE Contents Contents 1 Installation

More information

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease The NEW Greenstar i innovative intuitive improved performance installation ease A NEW look, NEW features and a NEW NAME for the UK s best selling boiler, the Greenstar i Junior 1 Introducing the new Greenstar

More information

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0 Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

User Manual THR840DUK Digital Thermostat

User Manual THR840DUK Digital Thermostat User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical

More information

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10 Programmable thermostat Thermostat programmable Termostato programable Read and save these instructions. Veuillez lire le mode d

More information

Overheating limit control

Overheating limit control Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. 2 Inch PowerVent LED Indicator Explanations & Troubleshooting Table

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. 2 Inch PowerVent LED Indicator Explanations & Troubleshooting Table New Robertshaw control valve was introduced in May 2008 as a replacement part. See last page for troubleshooting this replacement part. All voltage inputs are 120V. All electrical connectors are Molex

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

1 General information

1 General information 1 General information 1.1 About this manual This manual describes the installation, function and operation of an integrated solar control system, which is suitable for split pressurized solar heating system.

More information

instabus KNX / EIB System System E F G H

instabus KNX / EIB System System E F G H Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA

More information