Digital Lighting Systems, Inc.

Size: px
Start display at page:

Download "Digital Lighting Systems, Inc."

Transcription

1 Digital Lighting Systems, Inc. PD26-DMX Two Channel DMX Dimmer Pack (includes information for PD26-DMX-S) PD26-DMX S2 S 2 USER'S MANUAL PD26-DMX-UM 0/0

2 2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page GENERAL DESCRIPTION The PD26-DMX is a 2-channel DMX-52 compatible dimmer pack. It contains two printed circuit boards, the load driver module (LDM) and the INT0 control module. The LDM is equivalent to two solid-state relays (SSR's) assembled on a single circuit board. Power is fed to the PD26-DMX from two 20 Amp. breakers on the same electrical phase. Each breaker feeds a relay and each relay is rated for a maximum output current of 6 amperes. The LDM is mounted at the bottom of the PD26-DMX's enclosure which also serves as a heat sink. The relays are triggered by low-voltage signals generated by the INT0 module. These signals are optically-isolated by the LDM circuitry from all line voltage elements. A stepdown 0 VAC- transformer on the LDM board supplies power to the INT0. DMX-52 control information is received by the INT0 over a shielded twisted-pair cable. Several PD26-DMX dimmer packs may be daisy-chained together using standard DMX cables with 5-pin XLR type connectors. Each PD26-DMX may be set to a unique address and will occupy the next two DMX control channels beginning with the address selected at the front panel. When two or more units are set to the same address, their respective outputs work in unison, increasing the amount of load that can be controlled by a single DMX channel. Each of the PD26- DMX outputs may be independently configured not to dim. In such case, a DMX input value greater than switches its respective output to 00%, else the output remains at 0%. Figure shows a functional block diagram of the PD26-DMX. Figure shows PD26-DMX dimmers in a typical installation. DIMMING/SWITCHING - (See Page 8 for more information) A PD26-DMX may control a combination of dimmed and switched loads. Both of the PD26-DMX s outputs may be independently configured not to dim. This is achieved using a HARDWARE lock to ensure circuits do not dim. Both outputs controlled by the INT0 may be configured not to dim by the installation of a small jumper on the back of the INT0 circuit board. This may be done at the factory or in the field. This jumper may be removed to allow the future dimming of those outputs. Please see Page 8 for location of this jumper. Alternatively, the PD26-DMX may be ordered as a SWITCH-ONLY unit, the PD26-DMX-S. This unit has all the same features as the PD26 except that there is no dimming, and there are no chokes installed inside the unit. All other information in this manual is the same for both the PD26 and the PD26-S NW 8th Street, Miami, Fl. 26 Tel: or Fax: PD26-DMX-UM 0/0

3 BCDEF A BCDEF A 2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page 2 PD26-DMX Load Driver Module Information Figure - PD26-DMX LDM Detail INT0 Control Board J LDM SSR's OPTICAL ISOLATORS 5-Pin XLR Connectors Ground Load Driver Module SSR 9 VAC Transformer SSR NEUTRAL BUS Earth Ground H N N2 N N N5 N6 H2 Table - Terminals Definition NAME DESCRIPTION Output Of Solid-State Relay # Output Of Solid-State Relay # H Hot Line Feed For Relay. H2 Hot Line Feed For Relay. N-N6 Neutral Bus Connections. Table 2 - Absolute Maximum Electrical Ratings Electrical Characteristic Terminal Maximum Relay Load Current & 6 Amps. Input Current For Relay H 20 Amps. Input Current For Relay H2 20 Amps. Input Voltage H-H2 20 VAC, -Phase. PD26-DMX: INT0 Detail Table - INT0 Circuit Legend INT0 Circuit Legend Microprocessor. 2 Nonvolatile Memory. Communications Chip. Quartz Crystal. 5 Power Supply Capacitor. 6 Voltage Regulator. 7 Signal & Power Connector. 8 Output LED Monitors. S-2 Address Selectors. S Address Expansion 5 Components Side INT0 S S S 7 S Address Expansion Jumper (S) On Solder Side Solder Side INT0 2 S S2 8 S NOTE: PD26-DMX has one INT0 control board. Figure 2 - PD26-DMX INT0 Detail 7588 NW 8th Street, Miami, Fl. 26 Tel: or Fax: PD26-DMX-UM 0/0

4 2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page Figure - PD26-DMX Dimensional Diagram 8.0" (2 mm) Bottom View /2 and / Conduit Knockouts.2" (05 mm) IN 5 2 OUT 5 2 Top View.9" (8 mm) 2.600" (66 mm) DMX Ports 2.5" (55 mm) 2" (5 mm) 2" (5 mm) 2.5" (55 mm) 2.000" (5 mm).500" (8 mm) 5" (27 mm) LDM - Load Driver Module H 2 N N2 N N N5 N6 H2.07" (28 mm) T T.75" (298 mm) ADDRESS SELECTORS INT0 S2 S C 0 VAC Transformer W J 8 5" (27 mm) LED's OPTO-ISOLATORS 2 W2 J J2 0 0 PD26-DMX ( LDM) Load Driver Module C 0.75" (9 mm) LED OUTPUT MONITORS 2 PD26-DMX Front Cover Enclosure Installation Surface mount the dimmer pack in a well ventilated area where the ambient temperature does not exceed 90 F for full load operation. Allow " of side clearance for proper air circulation. Installation clearance shall meet local and/or NEC code requirements. Enclosures may be attached to the wall or other mounting surface by holes in the heat sink flanges. Refer to the drawings above for the proper dimensions. Conduit shall be pulled to the top of the dimmer packs. NOTE The PD26-DMX may create a buzzing noise and should not be located where this is objectionable. Figure - Typical Installation DMX CONTROL EQUIPMENT #2 AWG Typical To Distribution Panel PD26-DMX To Loads #2 AWG Typical To Distribution Panel PD26-DMX DMX-CC-LEN -Standard DMX Cable with 5-pin XLR Connectors To Loads Table - XLR DMX Connectors Pin Assignment Pin Function Pin No. Ground Shield -DATA 2 +DATA Empty Empty OUT IN 7588 NW 8th Street, Miami, Fl. 26 Tel: or Fax: PD26-DMX-UM 0/0

5 2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page PD26-DMX-20 General Wiring Instructions Wiring Notes 0 DO NOT EXCEED 920 W (6 Amps. ) per dimmer 20VAC. 0 All wiring between the dimmers and controller (network bus) is low voltage (NEMA Class 2) and may be run with two, twisted pair, shielded #8 AWG wire. 0 PD26-DMX dimmer packs may be fed by one or two 20 A (maximum) branch circuits and may have up to two separately dimmed/switched loads. 0 Both breakers must be on the same power phase. 0 CAUTION: DO NOT attempt to parallel outputs to increase capacity. 0 Installations must conform to local and/or NEC code requirements. 0 Each load must have its own Neutral wire for full load operation. 0 All line voltage wires must have copper conductors of adequate Gauge with 90 C wire insulation. 0 POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE PD26-DMX TO ENSURE PROPER WIRING. Figure 5 - PD26-DMX Typical 20 VAC Wiring. CAUTION PD26-DMX-20 VAC Models ONLY INT0 Control Board LDM SSR's OPTICAL ISOLATORS Load Driver Module SSR 9 VAC Transformer SSR NEUTRAL BUS H N N2 N N N5 N6 H2 LOAD # To Distribution Panel Neutral Bus LOAD #2 Earth Ground Electrical Distribution Panel ON ON 2x20 A - 20 VAC Breakers On Same Phase J For Full Load Operation Use: #2 AWG copper conductor wire for Line & Neutral Feeds. # AWG copper conductors in/out to each load. Max. Load: 6 Amperes (920W at 20 VAC) NW 8th Street, Miami, Fl. 26 Tel: or Fax: PD26-DMX-UM 0/0

6 PD26-DMX 2-Channel Dimmer Pack Digital Lighting Systems User's Manual - Page 5 PD26-DMX-220 General Wiring Instructions Wiring Notes 0 DO NOT EXCEED 80 W (6 Amps. ) per dimmer 20VAC. 0 All wiring between the dimmers, and controller (network bus) is low voltage (NEMA Class 2) and may be run with two, twisted pair, shielded #8 AWG wire. 0 PD26-DMX dimmer packs may be fed by one or two 20 A (maximum) branch circuits and may have up to two separately dimmed.switched loads. 0 Both breakers must be on the same power phase. 0 CAUTION: DO NOT attempt to parallel outputs to increase capacity. 0 Installations must conform to local and/or NEC code requirements. 0 Each load must have its own Neutral wire for full load operation. 0 All line voltage wires must have copper conductors of adequate Gauge with 90 C wire insulation. 0 POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE PD26-DMX, TO ENSURE PROPER WIRING. Figure 6 - PD26 Typical 220/20 VAC Wiring. CAUTION PD26-220/20 VAC Models ONLY INT0 Control Board LDM SSR's OPTICAL ISOLATORS Load Driver Module SSR 9 VAC Transformer SSR NEUTRAL BUS H N N2 N N N5 N6 H2 LOAD # To Distribution Panel Neutral Bus LOAD #2 Earth Ground Electrical Distribution Panel ON ON 2x20 Amp 220 to 20 VAC Breakers On Same Phase J For Full Load Operation Use: #2 AWG copper conductor wire for Line & Neutral Feeds. # AWG copper conductors in/out to each load. Max. Load: 6 Amperes (80W at 20 VAC) NW 8th Street, Miami, Fl. 26 Tel: or Fax: PD26-DMX-UM 0/0

7 2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page 6 Figure 7 - PD26-DMX-2/2 Low Voltage Load and Power Wiring CAUTION PD26-DMX-2/2 Models ONLY Electrical Distribution Panel NEUTRAL X PRIMARY SECONDARY ON 2v or 2v Transformer X LDM Load Driver Module SSR H LOAD # INT0 Control Board SSR's OPTICAL ISOLATORS Voltage Divider Network NEUTRAL BUS N N2 N N N5 N6 SSR H2 LOAD #2 J For Full Load Operation Use: #2 AWG copper conductor wire for Line & Neutral Feeds. # AWG copper conductors in/out to each load. Max. Load per circuit : 6 Amperes (8W at 2 VAC). NOTES With PD26-DMX-2 you may use a single 2 VAC-800 VA or better transformer or two separate 2 VAC-00 VA or better transformers. 2 With PD26-DMX-2 you may use a single 2 VAC-00 VA or better transformer or two separate 2 VAC-200 VA or better transformers. Follow transformer's installation & wiring instructions from manufacturer. Maximum Load Per Output: 92 Watts at 2 VAC. 5 Maximum Load Per Output: 8 watts at 2 VAC NW 8th Street, Miami, Fl. 26 Tel: or Fax: PD26-DMX-UM 0/0

8 5 6 8 S2 S 7 2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page 7 DMX Address Setting Up to 256 PD26-DMX dimmer packs may be installed per system and their DMX input daisy-chained using standard DMX-52 cables. Different addresses ranging from to 5 may be selected for each dimmer, depending on which DMX channel(s) will be used to control it. Each dimmer pack uses 2 consecutive DMX bytes from the input stream beginning at the address selected using rotary selectors S, S2 and address expansion jumper S. (See Figure on page 2 for selectors location). The PD26-DMX is shipped from the factory with jumper S installed allowing a DMX address range between and 256 to be selected by S & S2 (See Table ). For higher addresses ( ) jumper S must be removed (See Table 5). Non-Dim Output Setting Either or both of the PD26-DMX outputs may be configured for non-dim (switch only) operation. This prevents inadvertent dimming, or damage, of loads that cannot be dimmed, such as contactors, mechanical relays, motors, non-dim fluorescent, etc... Since this procedure involves adding external wire jumpers to the INT0 board, it is preferable to have it performed by the factory, at time of order. However, a qualified electronic technician can perform the procedure in the field when necessary. Figure 8 shows the location for installing the non-dim (ND) jumpers. The numbers shown next to the ND jumpers represent the corresponding output number of the PD26- DMX. Installing an ND jumper makes the corresponding output non-dim (switch only). A DMX value greater than turns a non-dim output to full intensity. A DMX value of or less turns it fully off. BEFORE ENERGIZING THE PD26-DMX MAKE SURE: 0 Loads are tested before connecting to dimmers. 0 Breaker feed lines are on same electrical phase. 0 PD26-DMX has been properly grounded. 0 All line voltage screw terminals are properly tightened to prevent hot spots. 0 Low voltage data lines connections are properly insulated. 0 Low voltage data lines polarity is observed throughout the system. 0 The PD26-DMX is set to the right address. INT0 Solder (Back) Side INT0 2 ND ND2 Non-Dim Jumpers ND-ND2 Installed Output Is Non-Dim (Switch Only) Removed Normal Dimmer Output. 0 5 Unit is shipped without ND jumpers. Address Expansion Jumper (S) Installed (S2,S) Address Range: -256 Removed (S2,S) Address Range: S Figure 8 - PD26-DMX Address & Mode Selection NW 8th Street, Miami, Fl. 26 Tel: or Fax: PD26-DMX-UM 0/0

9 2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page 8 PD26-DMX Address Selection Information Table - Addresses -256 Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S A0 9 C0 225 E A 9 C 226 E A2 95 C2 227 E A 96 C 228 E A 97 C 229 E A5 98 C5 20 E A6 99 C6 2 E A7 200 C7 22 E A8 20 C8 2 E A9 202 C9 2 E9 0A 2A 75 A 07 6A 9 8A 7 AA 20 CA 25 EA 2 0B 2B 76 B 08 6B 0 8B 72 AB 20 CB 26 EB 0C 5 2C 77 C 09 6C 8C 7 AC 205 CC 27 EC 0D 6 2D 78 D 0 6D 2 8D 7 AD 206 CD 28 ED 5 0E 7 2E 79 E 6E 8E 75 AE 207 CE 29 EE 6 0F 8 2F 80 F 2 6F 8F 76 AF 208 CF 20 EF B0 209 D0 2 F B 20 D 22 F B2 2 D2 2 F B 22 D 2 F B 2 D 25 F B5 2 D5 26 F B6 25 D6 27 F B7 26 D7 28 F B8 27 D8 29 F B9 28 D9 250 F9 27 A 59 A 9 5A 2 7A 55 9A 87 BA 29 DA 25 FA 28 B 60 B 92 5B 2 7B 56 9B 88 BB 220 DB 252 FB 29 C 6 C 9 5C 25 7C 57 9C 89 BC 22 DC 25 FC 0 D 62 D 9 5D 26 7D 58 9D 90 BD 222 DD 25 FD E 6 E 95 5E 27 7E 59 9E 9 BE 22 DE 255 FE 2 F 6 F 96 5F 28 7F 60 9F 92 BF 22 DF 256 FF Table 5 - PD26-DMX Decimal to Hexadecimal Address Chart. Address Selection Chart Using S2-S with JUMPER INSTALLED 7588 NW 8th Street, Miami, Fl. 26 Tel: or Fax: PD26-DMX-UM 0/0

10 2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page 9 PD26-DMX Address Selection Information Table 5 - Addresses Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S A0 9 C0 8 E A 50 C 82 E A2 5 C2 8 E A 52 C 8 E A 5 C 85 E A5 5 C5 86 E A6 55 C6 87 E A7 56 C7 88 E A8 57 C8 89 E A9 58 C9 90 E A 299 2A A 6 6A 95 8A 27 AA 59 CA 9 EA 268 0B 00 2B 2 B 6 6B 96 8B 28 AB 60 CB 92 EB 269 0C 0 2C C 65 6C 97 8C 29 AC 6 CC 9 EC 270 0D 02 2D D 66 6D 98 8D 0 AD 62 CD 9 ED 27 0E 0 2E 5 E 67 6E 99 8E AE 6 CE 95 EE 272 0F 0 2F 6 F 68 6F 00 8F 2 AF 6 CF 96 EF B0 65 D0 97 F B 66 D 98 F B2 67 D2 99 F B 68 D 500 F B 69 D 50 F B5 70 D5 502 F B6 7 D6 50 F B7 72 D7 50 F B8 7 D8 505 F B9 7 D9 506 F9 28 A 5 A 7 5A 79 7A 9A BA 75 DA 507 FA 28 B 6 B 8 5B 80 7B 2 9B BB 76 DB 508 FB 285 C 7 C 9 5C 8 7C 9C 5 BC 77 DC 509 FC 286 D 8 D 50 5D 82 7D 9D 6 BD 78 DD 50 N/A 287 E 9 E 5 5E 8 7E 5 9E 7 BE 79 DE 5 N/A 288 F 20 F 52 5F 8 7F 6 9F 8 BF 80 DF 52 N/A Table 6 - PD26-DMX Decimal to Hexadecimal Address Chart. Address Selection Chart Using S2-S with JUMPER REMOVED 7588 NW 8th Street, Miami, Fl. 26 Tel: or Fax: PD26-DMX-UM 0/0

11 LIMITED WARRANTY Digital Lighting Systems, warrants to the purchaser that its products have been carefully manufactured and inspected and are warranted to be free from defects of workmanship and materials when used as intended. Any abuse or misuse contrary to normal operation shall void this warranty. Digital Lighting Systems' obligation under this warranty shall be limited to replacement or repair of any units as shall within two years of date of invoice from Digital Lighting Systems, prove defective; and Digital Lighting Systems shall not be liable for any other damages, whether direct or consequential. The implied warranties of merchantability and fitness for a particular purpose are limited to the duration of the expressed warranty. Some states do not allow the exclusion of the limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, you may also have other legal rights which vary from state to state. Upon request, replacement unit(s) will be shipped as soon as available. Unless immediate shipment of replacement merchandise is requested, Digital Lighting Systems will not ship replacement merchandise until defective merchandise is received, inspected, and determined to be defective. No labor charges in connection with warranty problems will be reimbursed by Digital Lighting Systems without prior written approval from the factory. Digital Lighting Systems distributors and representatives have no authority to change this warranty without written permission. Digital Lighting Systems reserves the right to determine the best method of correcting warranty problems. Defective merchandise may be returned to Digital Lighting Systems, prepaid, after prior notification has been given and approval obtained for the return. To obtain prior approval for the return of the defective items, contact your local Digital Lighting Systems distributor, representative, or: Digital Lighting Systems, Inc. Attn: Customer Service Department 7588 NW 8th Street Miami, FL 26 (05) 26-89

12 Digital Lighting Systems, Inc NW 8th Street Miami, FL 26 Tel Fax e-m Printed in U.S.A. April 200

Digital Lighting Systems, Inc. PD408. Four Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD408-UM Rev. E - 02/03

Digital Lighting Systems, Inc. PD408. Four Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD408-UM Rev. E - 02/03 Digital Lighting Systems, Inc. Four Channel Dimmer and Switch Packs PROTOCOL S2 S 2 3 USER'S MANUAL Rev. E - 02/03 -Channel Dimmer Pack Digital Lighting Systems User's Manual - Page GENERAL DESCRIPTION

More information

2408 CD / CR DIMMER SYSTEM

2408 CD / CR DIMMER SYSTEM 2408 CD I CR DIMMER SYSTEM INTRODUCTION INTRODUCTION 2408 CD / CR DIMMER SYSTEM INSTALLATION AND OPERATION GUIDE The NSI 2408 dimmer represents a key part of a state of the art, total lighting control

More information

NSI DIGITAL DIMMING SYSTEM DDS 6000 DIMMER PACK

NSI DIGITAL DIMMING SYSTEM DDS 6000 DIMMER PACK DDS 6000 DIMMER PACK INTRODUCTION INTRODUCTION NSI DIGITAL DIMMING SYSTEM DDS 6000 DIMMER PACK INSTALLATION AND OPERATION GUIDE The NSI DDS 6000 represents a key part of a state of the art, integrated

More information

Visa Smart Debit/Credit Certificate Authority Public Keys

Visa Smart Debit/Credit Certificate Authority Public Keys CHIP AND NEW TECHNOLOGIES Visa Smart Debit/Credit Certificate Authority Public Keys Overview The EMV standard calls for the use of Public Key technology for offline authentication, for aspects of online

More information

DIMMERMASTER 124 DIGITAL WALLMOUNT DIMMER OWNER'S MANUAL DM-124-WM

DIMMERMASTER 124 DIGITAL WALLMOUNT DIMMER OWNER'S MANUAL DM-124-WM DIMMERMASTER 124 DIGITAL WALLMOUNT DIMMER OWNER'S MANUAL DM-124-WM Dove Lighting Systems, Inc. 3563 Sueldo Street Unit E San Luis Obispo, CA 93401 +1 805 541 8292 fax +1 805 541 8293 dove@dovesystems.com

More information

DIMMERMASTER 406 DIGITAL SHOEBOX DIMMER OWNER'S MANUAL DM406

DIMMERMASTER 406 DIGITAL SHOEBOX DIMMER OWNER'S MANUAL DM406 DIMMERMASTER 406 DIGITAL SHOEBOX DIMMER OWNER'S MANUAL DM406 Dove Lighting Systems, Inc. 3563 Sueldo Street Unit E San Luis Obispo, Ca 93401 +1 805 541 8292 fax +1 805 541 8293 dove@dovesystems.com / www.dovesystems.com

More information

Elegance Electrician s Guide

Elegance Electrician s Guide Elegance Electrician s Guide CentraLite Systems, Inc. 6420 Wall Street Mobile, AL 36695 Phone: (251) 607-9119 Fax: (251) 607-9117 CentraLite Systems, Inc. Revised by: Phone: +61 403 117 678 Email: www.in-touch.com.au

More information

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS NSI DIGITAL DIMMING SYSTEM NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS Software Revision 1.41, Version C UL, Mfg Q3/96, and above SPECIFICATIONS Number of Channels: 9800 : 8 channels Output capacity:

More information

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Applied Electronics. Commercial Dimming System UPDATE NOTICE REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with

More information

Power Enclosure MPER/SPER(S) -2/4-(IC36/24)

Power Enclosure MPER/SPER(S) -2/4-(IC36/24) I n s t a l l a t i o n 1061 S OUTH 800 E AST O REM, U TAH 84097 T ELEPHONE 801.229.2800 F ACSIMILE 801.224.0355 www.vantagecontrols.com Power Enclosure MPER/SPER(S) -2/4-(IC36/24) Overview The Vantage

More information

ZN-NH22XE Quick User Guide

ZN-NH22XE Quick User Guide ZN-NH22XE Quick User Guide This manual has been designed to guide you through basic installation, configuration and the webpage access settings of the device. Step1. Install the lens 1. Place the lens

More information

Crestron DIN-BLOCK DIN Rail Cresnet Distribution Block Operations & Installation Guide

Crestron DIN-BLOCK DIN Rail Cresnet Distribution Block Operations & Installation Guide Crestron DIN-BLOCK DIN Rail Cresnet Distribution Block Operations & Installation Guide This document was prepared and written by the Technical Documentation department at: Regulatory Compliance This product

More information

User Manual. SCRimmer STIK. Revision 4, September

User Manual. SCRimmer STIK. Revision 4, September SCRimmer STIK User Manual Revision, September 998 00-00 998 Electronics Diversified, Inc. SCRimmer is a registered trademark of Electronics Diversified, Inc. Installation Location: Mounting: Loads: Although

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide This manual has been designed to guide you through basic settings of your IP devices, such as installation and configuration for using them. Step1. Assemble and install IP device

More information

Civacon 8130 Optic Rack Monitor System and Associated Equipment

Civacon 8130 Optic Rack Monitor System and Associated Equipment Manual Part Number: 1 Civacon 8130 Optic Rack Monitor Manual Part Number: Table of Contents Section Description Page 1 Product Description... 3 1.1 Products... 4 1.2 Voltage Selection... 4 2 Mounting Diagram...

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

EX-A1 I/O Expansion Module Adapter

EX-A1 I/O Expansion Module Adapter EX-A1 I/O Expansion Module Adapter The EX-A1 interfaces between a variety of I/O expansion modules and specific Unitronics OPLCs. A single adapter can be connected to up to 8 expansion modules. The EX-A1

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

PDA1004 & PDA1044 Relay & I/O Expansion Module Instruction Manual

PDA1004 & PDA1044 Relay & I/O Expansion Module Instruction Manual PDA1004 & PDA1044 Relay & I/O Expansion Module PRECISION DIGITAL CORPORATION 89 October Hill Road Holliston MA 01760 USA Tel (800) 343-1001 Fax (508) 655-8990 www.predig.com Disclaimer The information

More information

DIMMERMASTER 406 DIGITAL SHOEBOX DIMMER

DIMMERMASTER 406 DIGITAL SHOEBOX DIMMER DIMMERMASTER 406 DIGITAL SHOEBOX DIMMER OWNER'S MANUAL TABLE OF CONTENTS 1 - RECEIVING YOUR EQUIPMENT 2 - FEATURES 3 - INSTALLATION A MECHANICAL INSTALLATION B ELECTRICAL INSTALLATION C GROUNDING D LOAD

More information

Installation and Operating Manual

Installation and Operating Manual DC DRIVE BC153 ELECTRONIC FORWARD BRAKE REVERSE Installation and Operating Manual 6/98 MN1370 TABLE OF CONTENTS Section Page i. Safety Warning... 1 I. Operation... 2 II. Setup... 2 III. Mounting... 3 IV.

More information

Micro-OPLC Installation Guide

Micro-OPLC Installation Guide Jazz OPLC JZ20-R31 Micro-OPLC Installation Guide 16 Digital, 2 Analog/Digital, 2 Analog Inputs, 11 Relay Outputs Before using this product, the user must read and understand this document. For additional

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121309B OWNERS

More information

Quick Installation Guide

Quick Installation Guide O1 N 2 3 4 5 6 7 8 O1 N 2 3 4 5 6 7 8 Quick Installation Guide This manual has been designed to guide you through basic settings of your IP devices, such as installation and configuration for using them.

More information

CMB24D DMX. 24 Channel DC Controller. User Manual June 1, 2013 V1.00 Copyright Light O Rama, Inc. 2013

CMB24D DMX. 24 Channel DC Controller. User Manual June 1, 2013 V1.00 Copyright Light O Rama, Inc. 2013 DMX 24 Channel DC Controller User Manual June 1, 2013 V1.00 Copyright Light O Rama, Inc. 2013 Table of Contents Introduction... 4 What s in the Box... 5 Applications... 5 Metal Tab Transistor Consideration...

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121539D OWNERS

More information

Airpax Dimensions, Inc.

Airpax Dimensions, Inc. Airpax Dimensions, Inc. 4467 White Bear Parkway (651) 653-7000 St. Paul, MN 55110-7626 Fax (651) 653-7600 OWNERS MANUAL JANUARY 2007 ISO 9001:2000 Certified Company 121139C Airpax Dimensions, Inc. DC to

More information

INSTALLATION -OR- * InFusion controllers have a micro-sd flash card port for backup.

INSTALLATION -OR- * InFusion controllers have a micro-sd flash card port for backup. INSTALLATION VANTAGECONTROLS.COM VANTAGE INSTALL GUIDES 1061 South 800 East, Orem, Utah 84097 Telephone: 801 229-2800 Fax: 801 224-0355 Commercial Power Enclosure Solutions MODEL: LCAP32M/S & LCAP44M/S

More information

CIVACON OPTIC RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

CIVACON OPTIC RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT OPTIC RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT INSTALLATION AND WIRING INSTRUCTIONS MANUAL 8130 MANUAL PART NUMBER JANUARY 2005 / A DOVER RESOURCES CO. 4304 MATTOX RD. KANSAS CITY, MO 64150 TABLE OF

More information

IO-DI8ACH I/O Expansion Module Eight 110/220VAC Inputs

IO-DI8ACH I/O Expansion Module Eight 110/220VAC Inputs IO-DI8ACH I/O Expansion Module Eight 110/220VAC Inputs The IO-DI8ACH is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. Each module offers 8 AC digital

More information

UNICOM 2500 UNICOM 2500. Installation Operation Programming. Universal Communication Converter

UNICOM 2500 UNICOM 2500. Installation Operation Programming. Universal Communication Converter User Manual UNICOM 2500 Installation Operation Programming Universal Communication Converter UNICOM 2500 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel 516.334.0870 Fax 516.338.4741

More information

Quick Installation Guide TBK-SER1001

Quick Installation Guide TBK-SER1001 Quick Installation Guide TBK-SER1001 This manual has been designed to guide you to basic settings of your IP devices such as installation and configuration for using them. 1. Connect cables to IP device

More information

AE-373 SERIES ELAPSED TIME / RUN TIME ACCUMULATOR

AE-373 SERIES ELAPSED TIME / RUN TIME ACCUMULATOR FN:373MAN1.DOC AE-373 SERIES ELAPSED TIME / RUN TIME ACCUMULATOR DESCRIPTION AE-373 Series Elapsed Time / Run Time Accumulators are available with 1", 2.3", 4", 8", or 12" high digits, visible from 5 feet

More information

LED Light Panel Installation Guide

LED Light Panel Installation Guide 100mm 85 Royal Crest Court, Unit 1-2 Markham ON, L3R 9X5 Canada Installation Guide Wiring 1 Switching 100-240VAC 50/60Hz, 0.3A 12VDC, 1.0A, 12W UL, cul Dimensions 1 3/4 x 2 3/4 x 1 1/8 1. LED light panels

More information

Type: Universal Relais Modbus protocol description. EA-Nr.: 1451 Replace for: Page: 1 von 9

Type: Universal Relais Modbus protocol description. EA-Nr.: 1451 Replace for: Page: 1 von 9 EA-Nr.: 1451 Replace for: Page: 1 von 9 MODBUS TCP/IP TCP Port: 502 Max. TCP connections): 5 MODBUS RTU Supported function codes Function code Name Utilization 3 (03H) Read Holding Registers Read data

More information

Type: Universal Relais Modbus protocol description. EA-Nr.: 1451 Replace for: Page: 1 von 10

Type: Universal Relais Modbus protocol description. EA-Nr.: 1451 Replace for: Page: 1 von 10 EA-Nr.: 1451 Replace for: 12280-1605-00 Page: 1 von 10 MODBUS TCP/IP TCP Port: 502 Max. TCP connections): 5 MODBUS RTU Connection diagram RS 485 Connection name Modbus Ziehl EIA/TIA-485 - wire D0 B (B

More information

Regulatory Compliance The cabinet and modules are Listed to applicable UL Standar ds and requirements by Underwriters Laboratories Inc.

Regulatory Compliance The cabinet and modules are Listed to applicable UL Standar ds and requirements by Underwriters Laboratories Inc. GREEN LIGHT EXPRESS Power Switching Cabinet GLPX-HSW-FT Introduction CRESTRON GREEN LIGHT EXPRESS power switching cabinets come pre-configured with GLXP switching modules already installed. The cabinets

More information

DIGITAL LIGHTING PROTOCOL GENERATOR

DIGITAL LIGHTING PROTOCOL GENERATOR OPERATION MANUAL FOR DMX DIGITAL LIGHTING PROTOCOL GENERATOR SOFTWARE VERSION V1.10 GODDARD DESIGN CO. 51 NASSAU AVE. Brooklyn, New York 11222 718 522-0170 718 599-0172 fax Copyright by Goddard Design

More information

RI-2 Relay Interface. Installation guide

RI-2 Relay Interface. Installation guide RI-2 Relay Interface Installation guide Contents Introduction 2 Welcome 2 Dimensions 2 Specification 2 Safety 3 Please read this first 3 Mounting 4 Location and spacing 4 Ambient atmosphere requirements

More information

C-5 LATCHING LOCKOUT MODULE

C-5 LATCHING LOCKOUT MODULE Catalog No.: 5000.58A Effective: 4-09-08 Replaces: 2-01-98 C-5 LATCHING LOCKOUT MODULE Installation and Operating Manual PN 240722 Rev. 2 C-5 LATCHING LOCKOUT MODULE Installation and Operating Manual Before

More information

The ART Model 311 USER S GUIDE

The ART Model 311 USER S GUIDE The ART Model 311 Precision Stereo 2-Way Active Crossover with Subwoofer Output USER S GUIDE - 1 - TABLE OF CONTENTS Introduction... 3 Installation... 4 AC Power Hookup... 4 Analog Audio Connections...

More information

VISIX Time of Flight People Tracking Camera VX-VTOF-01 Quick Start Guide v VISIX Time of Flight Quick Start Guide VX-VTOF-01

VISIX Time of Flight People Tracking Camera VX-VTOF-01 Quick Start Guide v VISIX Time of Flight Quick Start Guide VX-VTOF-01 VISIX Time of Flight Quick Start Guide VX-VTOF-01 VISIX Time of Flight People Tracking Camera VX-VTOF-01 Quick Start Guide v01-2016 10385 Westmoor Drive, Suite 210, Westminster, CO 80021 www.3xlogic.com

More information

24VDC Power Supply. I. Description...2. II. Installation A. Installing the D9142F B. Connecting AC Power C. Batteries...

24VDC Power Supply. I. Description...2. II. Installation A. Installing the D9142F B. Connecting AC Power C. Batteries... D9142F Operation and Installation 24VDC Power Supply Table of Contents: I. Description...2 II. Installation... 3 A. Installing the D9142F... 3 1. Mounting the Enclosure... 3 2. Installing the D9142M...

More information

ADDRESSABLE DIMMER PACKS

ADDRESSABLE DIMMER PACKS ND 4600/ ND 5000 ADDRESSABLE DIMMER PACKS OPERATION MANUAL Page 1 of 9 INTRODUCTION Dimmer packs are the heart of any stage lighting system. They translate coded signals generated by controllers into power

More information

GLS-PLS-120/277. Functional Summary

GLS-PLS-120/277. Functional Summary Functional Summary The GLS-PLS-120/277 is a 3-phase power loss sensor designed for use with Crestron Green Light systems to activate Override mode during a power failure. In response to a signal from the

More information

CBC-200 Series & CBC-200C Series Single Channel Adjust Clutch/Brake Controls P

CBC-200 Series & CBC-200C Series Single Channel Adjust Clutch/Brake Controls P CBC-200 Series & CBC-200C Series Single Channel Adjust Clutch/Brake Controls P-269 89-0407 Installation & Operating Instructions Contents Introduction........................... 2 Specifications.........................

More information

EX-A2X I/O Expansion Module Adapter, Isolated

EX-A2X I/O Expansion Module Adapter, Isolated EX-A2X I/O Expansion Module Adapter, Isolated The EX-A2X interfaces between a variety of I/O expansion modules and specific Unitronics OPLCs. A single adapter can be connected to up to 8 expansion modules.

More information

NR 3000 OPERATION MANUAL

NR 3000 OPERATION MANUAL NR 3000 PROGRAMMABLE RELAY PACK OPERATION MANUAL - - --- INTRODUCTION Dimmer and relay packs are the heart of any stage lighting system. They translate coded signals generated by controllers into power

More information

E 4 BOILER ALARM ANNUNCIATOR

E 4 BOILER ALARM ANNUNCIATOR Catalog No.: 5000.55B Effective: 4-09-08 Replaces: 5-01-98 E 4 BOILER ALARM ANNUNCIATOR Installation and Operating Manual PN 240691 Rev. 3 E 4 BOILER ALARM/ANNUNCIATOR Installation and Operating Manual

More information

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Failure to comply with appropriate safety guidelines can cause severe injury or property damage. Jazz OPLC Micro-OPLC Installation Guide JZ20-R10/JZ20-J-R10 6 Digital Inputs, 4 Relay Outputs JZ20-R16/JZ20-J-R16 6 Digital, 2 Analog/Digital, 2 Analog Inputs, 6 Relay Outputs Before using this product,

More information

1204 Reflected Wave Reduction Device with Common Mode Choke (Catalog Number 1204-RWC-17-A)

1204 Reflected Wave Reduction Device with Common Mode Choke (Catalog Number 1204-RWC-17-A) Installation Instructions 1204 Reflected Wave Reduction Device with Common Mode Choke (Catalog Number 1204-RWC-17-A) This publication will guide you through installation (including mounting, wiring and

More information

PDLPC416FR-KNX LightMaster Dimmer Actuator

PDLPC416FR-KNX LightMaster Dimmer Actuator WARNING Risk of electric shock. ISOLATE FROM MAINS SUPPLY PRIOR TO INSTALLATION OR SERVICING. Do not cut or NO USER SERVICEABLE PARTS INSIDE. INSTALLATION AND SERVICE BY QUALIFIED PERSONNEL ONLY terminate

More information

AS-42D COMPACT DMX DIMMER

AS-42D COMPACT DMX DIMMER OWNERS MANUAL AS-42D COMPACT DMX DIMMER Version 2.0 02/14/2005 Page 1 of 5 IMPORTANT: Please take a moment to read this manual before operating the AS-42D DImmer DESCRIPTION The AS-42D is a compact 4 channel

More information

Wireless Sync Device Model AT-MSX. Installation & User s Guide

Wireless Sync Device Model AT-MSX. Installation & User s Guide Wireless Sync Device Model AT-MSX Installation & User s Guide THIS EQUIPMENT COMPLIES WITH FCC CLASS-B REQUIREMENTS PURSUANT SUBPART J OF PART-15 This device complies with Part 15 of the FCC Rules. Operation

More information

ULD-360DMX and ULD-360DMX-HP USER S MANUAL

ULD-360DMX and ULD-360DMX-HP USER S MANUAL ULD-360DMX and ULD-360DMX-HP USER S MANUAL Copyright Leprecon LLC. 2005-2008 All rights reserved Publication 21-1046 Rev B This document is the property of Leprecon LLC, and is provided for service and

More information

ROTARY PHASE CONVERTERS 240 VOLT SERIES Model: EZ OPERATION & INSTALLATION MANUAL. American Rotary, LLC

ROTARY PHASE CONVERTERS 240 VOLT SERIES Model: EZ OPERATION & INSTALLATION MANUAL. American Rotary, LLC ROTARY PHASE CONVERTERS 240 VOLT SERIES Model: EZ OPERATION & INSTALLATION MANUAL American Rotary, LLC www.americanrotary.com 2014 EZ Phase / American Rotary 2 / 5 / LIFETIME LIMITED WARRANTY Rotary Phase

More information

Isolated Input/Output Relay Board

Isolated Input/Output Relay Board Isolated Input/Output Relay Board Catalog No. ACB003A01 Installation and Operating Manual 4/01 MN1325 Table of Contents Section 1 General Information................................... 1-1 Limited Warranty.....................................

More information

TC-4300 Temperature Controller Product Information Packet

TC-4300 Temperature Controller Product Information Packet TC-4300 Temperature Controller Product Information Packet 2/16 Table of Contents 1 INTRODUCTION...4 2 SPECIFICATIONS...5 2.1 Features...5 2.2 Part Numbers...6 3 DIMENSIONS...7 4 ELECTRICAL INSTALLATION

More information

Series Access Power Controllers. Installation Guide. Maximal3DV - 5 amp or 5.4 amp. - Sixteen (16) PTC protected outputs.

Series Access Power Controllers. Installation Guide. Maximal3DV - 5 amp or 5.4 amp. - Sixteen (16) PTC protected outputs. Series Access Power Controllers Installation Guide Models Include: Maximal3DV - 12VDC @ 5 amp or 24VDC @ 5.4 amp. - Sixteen (16) PTC protected outputs. Maximal5DV - 12VDC @ 9 amp. - Sixteen (16) PTC protected

More information

FAN DECK FEDERAL STANDARD 595B COLORS (July 1994) 2002 Rob Graham. Special thanks to Pete Chalmers.

FAN DECK FEDERAL STANDARD 595B COLORS (July 1994) 2002 Rob Graham. Special thanks to Pete Chalmers. 7690-01-162-2210 FAN DECK FEDERAL STANDARD 595B COLORS (July 1994) Introduction 2002 Rob Graham. Special thanks to Pete Chalmers. The Federal Standard 595B specification is a U.S. government paint color

More information

AccuSine Power Correction System (PCS) Models: N1, N12, CH, IP30, IP54

AccuSine Power Correction System (PCS) Models: N1, N12, CH, IP30, IP54 AccuSine Power Correction System (PCS) Models: N1, N12, CH, IP30, IP54 Installation Manual Part Number 9010021 Rev C Retain for future use 2011 Schneider Electric. All rights reserved. TABLE of CONTENTS

More information

IntelliComm Communication Center (For use with the IntelliFlo and IntelliPro pumps) Installation Guide

IntelliComm Communication Center (For use with the IntelliFlo and IntelliPro pumps) Installation Guide IntelliComm Communication Center (For use with the IntelliFlo and IntelliPro pumps) Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical Support

More information

Crestron TPS-17G-QM/-L-IMC Power Interface Module Operations Guide

Crestron TPS-17G-QM/-L-IMC Power Interface Module Operations Guide Crestron TPS-17G-QM/-L-IMC Power Interface Module Operations Guide This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh,

More information

ProPower. DC Power Supply

ProPower. DC Power Supply ProPower DC Power Supply SAFETY WARNING To avoid injury: Before installing ProPower on a machine, turn off the machine and disconnect it from its power source Warranty Accurate Technology, Inc., warrants

More information

Operation and Installation Manual

Operation and Installation Manual Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control

More information

user manual 2 2011 Mikro Sdn Bhd All Rights Reserved 2 inch, 64 x 128 dot matrix LCD display with back lighting Three phase and single phase detection of reactive power 12 (or 8 for 8 step model) output

More information

IO-TO16 I/O Expansion Module 16 Transistor Outputs

IO-TO16 I/O Expansion Module 16 Transistor Outputs IO-TO16 I/O Expansion Module 16 Transistor Outputs The IO-TO16 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 16 pnp (source) transistor.

More information

Component identification

Component identification IO-AI8 I/O Expansion Module 8 Analog Inputs The IO-AI8 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 analog inputs. The interface

More information

LightSync Line Voltage Dimmer Installation

LightSync Line Voltage Dimmer Installation LightSync Line Voltage Dimmer Installation This guide will provide basic information for installing the LightSync Line Voltage Dimmer control panel. Follow these instructions and all NEC and local code

More information

Side trigger event. Limitations that are important for users of the Bosch Crash Data Retrieval (CDR) tool on this Ford product to know

Side trigger event. Limitations that are important for users of the Bosch Crash Data Retrieval (CDR) tool on this Ford product to know IMPORTANT NOTICE: Robert Bosch LLC and the manufacturers whose vehicles are accessible using the CDR System urge end users to use the latest production release of the Crash Data Retrieval system software

More information

LP Dimming Panels. GRAFIK Systems

LP Dimming Panels. GRAFIK Systems lp-1 12.8.03 are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Work directly with incandescent, magnetic low voltage, and neon/cold

More information

MODEL SIMG KB Part No Signal Isolator for KBMG-212D Regenerative Drive

MODEL SIMG KB Part No Signal Isolator for KBMG-212D Regenerative Drive INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIMG KB Part No. 8832 Signal Isolator for KBMG-212D Regenerative Drive Pending! See Safety Warning on Page 1 The information contained in this manual is intended

More information

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2115-123 Block Upconverter November 2013, Rev. C MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

S940. Sensor Alarm Console Installation and Operation Guide

S940. Sensor Alarm Console Installation and Operation Guide S940 Sensor Alarm Console Installation and Operation Guide Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com Notice

More information

Write both the HMI and Ladder control application using U90 Ladder freeware.

Write both the HMI and Ladder control application using U90 Ladder freeware. M90/91 OPLC Installation Guide Models M90/91 This guide provides basic information for Unitronics M90/91 OPLC. General Description M90/91 OPLC are palm-sized programmable logic controllers that comprise

More information

AEXX-388-X SERIES MULTI-ZONE RS232 TIME ZONE CLOCK SYSTEM. (Includes AEXX-354 versions)

AEXX-388-X SERIES MULTI-ZONE RS232 TIME ZONE CLOCK SYSTEM. (Includes AEXX-354 versions) FN:388MAN1.DOC AEXX-388-X SERIES MULTI-ZONE RS232 TIME ZONE CLOCK SYSTEM (Includes AEXX-354 versions) DESCRIPTION AEXX-388-X Series Multi-Zone Displays are available with 1, 2.3, 4, 8, or 12 high digits,

More information

50 Hz Mini/Micro Computer Regulator (MCR) Series Installation and Operation Manual

50 Hz Mini/Micro Computer Regulator (MCR) Series Installation and Operation Manual Operating & Service Instructions Sola Minicomputer Regulators UL White Card Listed Power Supply Classification CSA Certified Transformer Classification General Description and Specifications 50 Hz Mini/Micro

More information

Dynamic Braking Options For Series H Controls

Dynamic Braking Options For Series H Controls Dynamic Braking Options For Series H Controls Installation & Operating Manual 2/02 Table of Contents Section 1............................................................................... 1-1 Overview.....................................................................................

More information

Installation and Operation Instructions ELI SERIES EMERGENCY LIGHTING INVERTERS. Ni - Cd

Installation and Operation Instructions ELI SERIES EMERGENCY LIGHTING INVERTERS. Ni - Cd ELI-S-100 WITH DIMMING CAPABILITIES Installation and Operation Instructions ELI SERIES LIGHTING INVERTERS NRTL/C! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD

More information

ROTOR ROUTER DMX512 DIGITAL PATCH BAY OWNERS MANUAL

ROTOR ROUTER DMX512 DIGITAL PATCH BAY OWNERS MANUAL ROTOR ROUTER DMX512 DIGITAL PATCH BAY OWNERS MANUAL Doug Fleenor Design 396 Corbett Canyon Road Arroyo Grande, CA 93420 (805) 481-9599 revision 1.0 May, 2000 TABLE OF CONTENTS Product Description 2 Specifications

More information

Quick Start Guide G-Code/EEC-2400

Quick Start Guide G-Code/EEC-2400 Quick Start Guide G-Code/EEC-2400 This manual provides instructions for quick installation and basic configuration of your IP device. 1. Part names and positions Please check names and positions of each

More information

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120. Vision OPLC Installation Guide Vision120 This guide provides basic information for Unitronics Vision120. General Description V120 OPLCs are micro-oplcs, rugged programmable logic controllers that comprise

More information

Owner s Manual Revision 1.06 NA

Owner s Manual Revision 1.06 NA Owner s Manual Revision 1.06 NA Model No. 50-120-240 60Hz 50 Amp AutoShore Comar Electrical Services Ltd. 114 1515 Broadway Street Port Coquitlam, BC Canada V3C 6M2 Tel: (604) 941-7646 Fax: (604) 941-7610

More information

10W LED COLOR SPOT. User Manual LED-PS10D RGBW. Professional Entertainment Technology

10W LED COLOR SPOT. User Manual LED-PS10D RGBW. Professional Entertainment Technology 10W LED COLOR SPOT LED-PS10D RGBW User Manual Professional Entertainment Technology TABLE OF CONTENTS 1. Safety Instruction 2. Technical Specification 3. Installation 4. How to Control the Unit 4.1 Control

More information

CAN-5901 Expansion I/O Module

CAN-5901 Expansion I/O Module CAN-5901 Expansion I/O Module Installation Guide Complete the following steps to install a Conquest CAN-5901 Expansion Module that will be connected to a Conquest BAC-5900 Series Controller. Refer to the

More information

M T E C o r p o r a t i o n MTE - SERIES RL LINE/LOAD REACTORS USER MANUAL PART NO. INSTR 011 REL MTE Corporation

M T E C o r p o r a t i o n MTE - SERIES RL LINE/LOAD REACTORS USER MANUAL PART NO. INSTR 011 REL MTE Corporation M T E C o r p o r a t i o n MTE - SERIES RL LINE/LOAD REACTORS USER MANUAL PART NO. INSTR 011 REL. 021126 2002 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RL Line/Load Reactors are components

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit NJ-PA/PD CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to

More information

OWNERS MANUAL Page 1 of 06. Revision /10/2000

OWNERS MANUAL Page 1 of 06. Revision /10/2000 OWNERS MANUAL Page 1 of 06 81,7Ã'(6&5,37,21Ã$1'Ã)81&7,216 The RM-121 is a 14,400 Watt, 12 channel, rack mountable lighting dimmer. Each of the channels has a capacity of 1200 Watts. It is controlled via

More information

FIREYE E320 EXPANSION MODULE

FIREYE E320 EXPANSION MODULE E-3201 APRIL 16, 2013 FIREYE E320 EXPANSION MODULE FOR USE WITH THE FIREYE FLAME-MONITOR CONTROL E320 CONTROL RIBBON CABLE E350 DESCRIPTION The FIREYE E320 Expansion Module provides increased interlock

More information

CS4 and CS8 Boiler Management System

CS4 and CS8 Boiler Management System Installation and Wiring Guide for the OnTrac CS4 and CS8 Boiler Management System 3220 Galvez Avenue - Fort Worth, Texas 76111 - Tel 1-800-990-5918 Page 1 TABLE OF CONTENTS Caution and Mounting of Control

More information

G 1 Alarm relay H 1 Dry alarm contacts TB 12

G 1 Alarm relay H 1 Dry alarm contacts TB 12 ACS-PCM-5 POWER CONTROL MODULE FOR USE WITH RAYCHEM ACS-UIT INSTALLATION INSTRUCTIONS DESCRIPTION The ACS-PCM-5 provides ground-fault and line current sensing, alarming, switching (electromechanical relays)

More information

Technical Data Sheet No. TDXXXXM Rev. B Date of Issue: March 9, 2006 OPERATING MANUAL FOR OSS-2. Optical Sensor Switch

Technical Data Sheet No. TDXXXXM Rev. B Date of Issue: March 9, 2006 OPERATING MANUAL FOR OSS-2. Optical Sensor Switch Technical Data Sheet No. TDXXXXM Rev. B Date of Issue: March 9, 2006 OPERATING MANUAL FOR OSS-2 Optical Sensor Switch TABLE OF CONTENTS 1. UNPACKING the Optical Sensor Switch... 1 1.1 Inspect Package for

More information

Specification Grade Dimming Panels

Specification Grade Dimming Panels Specification Grade Dimming Panels 8 Series Panels & Enclosures N/A N/A The Specification Grade Panel is meant for extreme dimming applications where high performance and minimized filament noise are paramount.

More information

USB-ERB24 Specifications

USB-ERB24 Specifications USB-ERB24 Specifications Document Revision 1.4, April, 2016 Copyright 2016, Measurement Computing Corporation All specifications are subject to change without notice. Typical for 25 C unless otherwise

More information

LUMA-NET 400CP REMOTE CONTROL PANEL

LUMA-NET 400CP REMOTE CONTROL PANEL LUMA-NET 400CP REMOTE CONTROL PANEL INSTALLATION AND OPERATION GUIDE INTRODUCTION The NSI 400CP represents a key part of a state of the art, total lighting control system. Combined with NSI dimmers and

More information

LUMA-NET 404CP / 408CP REMOTE CONTROL PANEL

LUMA-NET 404CP / 408CP REMOTE CONTROL PANEL LUMA-NET 404CP / 408CP REMOTE CONTROL PANEL INSTALLATION AND OPERATION GUIDE INTRODUCTION The NSI 404CP and 408CP represents a key part of a state of the art, total lighting control system. Combined with

More information

LOW-VOLTAGE OUTPUT STATION

LOW-VOLTAGE OUTPUT STATION LOW-VOLTAGE OUTPUT load controls LVOS-- Controls up to eight separate sets of LED, CFL, or CCFL lighting loads Ethernet port for Ethernet bus connection Communication via Station Bus or Ethernet Bus Firmware

More information

PMDX-108-Input. 8-Channel Isolated Input Board for PC parallel port pins 2-9. User s Manual

PMDX-108-Input. 8-Channel Isolated Input Board for PC parallel port pins 2-9. User s Manual PMDX-108-Input 8-Channel Isolated Input Board for PC parallel port pins 2-9 User s Manual Date: 25 February 2010 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA

More information

LED Light Panel Installation Guide

LED Light Panel Installation Guide 2700 John St. Markham ON, L3R 2W4 Canada T: 905-474-0555 Installation Guide Wiring 1 Switching 100-240VAC 50/60Hz, 0.3A 12VDC, 1.0A, 12W UL, cul Dimensions 1 3/4 x 2 3/4 x 1 1/8 3 Switching 100-240VAC

More information