International Standard Corresponding Indian Standard Degree of Equivalence
|
|
- Jonah Terry
- 7 years ago
- Views:
Transcription
1 DOC: ET 12(6671) BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE PART 1 : GENERAL REQUIREMENTS Last date for receipt of comments is Measuring Equipment for Basic Electrical Quantities Sectional Committee, ET 12 NATIONAL FOREWORD This Indian Standard (First Revision) which is identical with IEC (2010) Ed. 3.0 Safety Requirements for electrical equipment for measurement, control, and laboratory use Part 1 General requirements issued by the International Electrotechnical Commission (IEC) would be adopted by the Bureau of Indian Standards on the recommendations of the Measuring Equipment for Basic Electrical Quantities Sectional Committee, ET 12 and approval of the Electrotechnical Division Council. This standard was first published in 1979, which was based on IEC Pub IEC Pub has since been replaced by IEC Therefore this revision has been undertaken to bring it in line with International Practices. The text of IEC Standard has been approved as suitable for publication as an Indian Standard without deviations. Certain conventions are, however, not identical to those used in Indian Standards. Attention is particularly drawn to the following: a) Wherever the words International Standard appear, referring to this standard, they should be read as Indian Standard. b) Comma (,) has been used as a decimal marker while in Indian Standards, the current practice is to use a point (.) as the decimal marker. In this adopted standard, reference appears to certain International Standards for which Indian Standards also exist. The corresponding Indian Standards which are to be substituted in their places are listed below along with their degree of equivalence for the editions indicated: International Standard Corresponding Indian Standard Degree of Equivalence IEC (all parts) Letter symbols to be used in electrical technology IS 3722 (Part 1) : 1983 Letter symbols and signs used in i
2 IEC Audio, video and similar electronic apparatus Safety requirements IEC , Environmental testing Part 2-14: Tests Test N: Change of temperature IEC , Environmental testing Part 2-75: Tests Test Eh: Hammer tests IEC Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V IEC (all parts) Plugs, socket outlets and couplers for industrial purposes IEC (all parts), Appliance couplers for household and similar general purposes electrical technology: Part 1 General guidance on symbols and subscripts IS 3722 (Part 2) : 1983 Letter symbols and signs used in electrical technology: Part 2 Reference tables for symbols and subscripts IS 616 : 2003 / IEC : 2001 Audio, video and similar electronic apparatus Safety requirements IS 9000 (Part 4) : 1979 Basic environmental testing procedures for electronic and electrical items: Part 14 Test N: Change of temperature (First revision) IS 9000 (Part 7/Sec 7) : 2006 Basic environmental testing procedures for electronic and electrical items: Part 7 Impact Test, Test Eh: Hammer tests IS 694 : 1990 PVC Insulated cables for working voltages upto and including V IS/IEC (Part 1) : 2002 Plugs, socket outlets and couplers for industrial purposes : Part 1 General requirements (first revision) IS/IEC (Part 2) : 1999 Plugs, socket outlets and couplers for industrial purposes :Part 2 dimensional interchangeability requirements for pin and contact tube accessories (first revision) IS/IEC (Part 1) : 2001 Appliance couplers for household and similar general purposes: Part 1 General requirements IS/IEC (Part 2/Sec 2 ) : Equivalent Equivalent ii
3 1998 Appliance couplers for household and similar general purposes: Part 2 : Sec 2 Interconnection Couplers for Household and Similar Equipment IS/IEC (Part 2/Sec 3 ) : 1998 Appliance couplers for household and similar general purposes: Part 2 : Sec 3 Appliance couplers with a degree of protection higher than ipxo IEC , Household and similar electrical appliances Safety Part 2-24: Particular requirements for refrigerating appliances, ice cream appliances and ice makers IEC Degrees of protection provided by enclosures (IP Code) IEC Insulation coordination for equipment within low-voltage systems Part 3: Use of coatings to achieve insulation coordination of printed board assemblies IEC , Fire hazard testing Part 11-10: Test flames 50 W horizontal and vertical flame test methods IEC Low-voltage switchgear and controlgear Part 1 General rules IEC Low voltage switchgear and controlgear Part 3 Switches, disconnectors, switch IS 302(Part 2/Sec 24) : 1994 Safety of household and similar electrical appliances : Part 2 Particular requirements, Sec 24 Refrigerators, food freezers and ice makers IS 60529:2001 Classification of Degrees of protection provided by enclosures (IP Code) IS 15382(Part 3) : 2006 /IEC (2003) Insulation coordination for equipment within low-voltage systems: Part 3 Use of coating, potting or moulding for protection against pollution IS (Part 2/Sec 2 ) : 2008 Fire Hazard Testing : Part 2 Test Methods, Sec 2 Needle-flame Test Method Apparatus, Confirmatory Test Arrangement And Guidance IS (Part 1) : 1993 /IEC : 1988 Specification for low voltage switchgear and control gear: Part 1 General rules IS (Part 3) : 1993 /IEC : 1990 Specification for low voltage switchgear and iii
4 disconnectors and fuse combination units IEC , Electroacoustics Sound level meters Part 1: Specifications IEC , Electroacoustics Sound level meters Part 2: Pattern evaluation tests control gear: Part 3 Switches, disconnections, switch disconnections and fuse combination units IS (Part 1) : 2005 Electroacoustics Sound level meters : Part 1 Specification IS (Part 2) : 2005 Electroacoustics Sound level meters : Part 2 Pattern evaluation tests ISO 306 : 1994 Plastics Thermoplastic materials Determination of Vicat softening temperature (VST) IS 10810(Part 22) : 1984 Methods of test for cables : Part 22 Vicat softening point The technical committee has reviewed the provisions of the following International Standards referred in this adopted standard and has decided that they are acceptable for use in conjunction with this standard. International Standard IEC Title Basic and safety principles for man machine interface, marking and identification Coding principles for indicators and actuators IEC Tests on electric and optical fibre cables under fire conditions Part 1-2 : Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kw premixed flame IEC Tests on electric and optical fibre cables under fire conditions Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable Procedure for diffusion flame IEC Household and similar electrical appliances Safety Part 2-89: Particular requirements for commercial refrigerating appliances with an incorporated or remote refrigerant condensing unit or compressor IEC IEC Low voltage electrical installations Part 4-44: Protection for safety Protection against voltage disturbances and electromagnetic disturbances Nuclear instrumentation Constructional requirements and classification of radiometric gauges iv
5 IEC IEC IEC IEC (all parts) IEC IEC IEC Guide 104 ISO/IEC Guide 51 ISO 361 ISO 700 Graphical symbols for use on equipment Safety requirements for electrical equipment for measurement, control and laboratory use Part 031 : Safety requirements for hand held probe assemblies for electrical measurement and test High voltage test techniques for low voltage equipment Part 1 : Definitions, test and procedure requirements High-voltage test techniques for low voltage equipment High voltage test techniques for low voltage equipment Part 2 : Test equipment Degrees of protection provided by enclosures for electrical equipment against external impacts (IK code) The preparation of safety publications and the use of basic safety publications and group safety publications Safety aspects Guidelines for their inclusion in standards Basic ionizing radiation symbol Graphical symbols for use on equipment Only English language text has been retained while adopting it in this Indian Standard, and as such the page numbers given here are not the same as in the International Standard For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated expressing the result of a test, shall be rounded off in accordance with IS 2 : 1960 Rules for rounding off numerical values (revised). The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard Note: The technical content of the document is not available on website. For details, please refer the corresponding IEC ( 2010) or kindly contact: Head Electrotechnical Department Bureau of Indian Standards 9, B. S. Zafar Marg, New Delhi v
6 Telephone/ fax: vi
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,
More informationIEC PROJETOS EM VOTAÇÃO JULHO E AGOSTO. IEC 60034-1 Ed.13: Rotating electrical machines - Part 1: Rating and performance.
IEC PROJETOS EM VOTAÇÃO JULHO E AGOSTO IEC/TC 2 - Rotating machinery IEC 60034-1 Ed.13: Rotating electrical machines - Part 1: Rating and performance. IEC 60034-12 Ed.3: Rotating electrical machines -
More informationDEVICES OF PROTECTION AND COMMAND
COMPLEMENT Doc: 702-CRC-007-E Page: 1/24 Elaborated by: Laercio Santos Checked by: Karen Carolina Martins Rodrigo Omori Douglas Ferreira Nelson Coelho Approved by: Nelson Coelho Approval date: 14/07/2014
More information12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
More informationCommission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)
10.8.2002 Official Journal of the European Communities C 190/5 Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03) (Text with EEA relevance)
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE TESTING, LLC 1724 S Nevada Way Mesa, AZ 85204 Phone: 480 926 3100 Michael Schafer (Authorized Representative/President) Email michaels@compliancetesting.com
More informationW O R L D C L A S S H I F I
W O R L D C L A S S H I F I O W N E R S M A N U A L Accessories: NAPSC, i-supply, Headline, Stageline IMPORTANT In order to comply with current European safety regulations it is essential that the Naim
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60227-1 Edition 2.2 1998-03 Edition 2:1993 consolidated with amendments 1:1995 and 2:1997 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
More informationLV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
More informationThe Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
More informationSafety information. MSX-Box. ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany
DIN EN ISO9001:2008 certified ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany Phone: +49 7229 1847 0 Fax: +49 7229 1847 222 E-mail: info@addi-data.com Safety information
More informationHow To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
More informationThe Different Types of AC Power Connectors in North America
The Different Types of AC Power Connectors in North America White Paper #20 Executive Summary A confusing array of AC power plugs and receptacles exist to deliver power to various electronic loads. This
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60076-11 First edition 2004-05 Power transformers Part 11: Dry-type transformers This English-language version is derived from the original bilingual publication by leaving out
More informationThe Different Types of AC Power Connectors in North America
The Different Types of AC Power Connectors in North America White Paper 20 Revision 1 by James Spitaels > Executive summary A confusing array of AC power plugs and receptacles exist to deliver power to
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61892-1 First edition 2001-12 Mobile and fixed offshore units Electrical installations Part 1: General requirements and conditions Unités fixes et mobiles en mer Installations
More informationFAQs-Main switchboard design criteria
FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard
More informationNormas IEC en el TC 23 Electrical accessories - accesorios eléctricos
1 er Foro del Comité Electrotécnico Mexicano Normalización internacional - Productos confiables - Instalaciones eléctricas seguras Normas IEC en el TC 23 Electrical accessories - accesorios eléctricos
More informationElectrical Resistance Resistance (R)
Electrical Resistance Resistance (R) Any device in a circuit which converts electrical energy into some other form impedes the current. The device which converts electrical energy to heat energy is termed
More informationAbout us. Eugensa is an ISO 9001:2008 certified company. CERT
About us CERT Eugensa JSC was established in Lithuania in 1996 and since then has become one of the regions largest electrical contractors specialising in the design, installation and maintenance of electrical,
More informationNEC Ethiopia. By: Abreham Teka, NEC Secretary, Electrical Standards Officer at Ethiopian Standards Agency (ESA) IEC Affiliate Forum New Delhi, India
NEC Ethiopia By: Abreham Teka, NEC Secretary, Electrical Standards Officer at Ethiopian Standards Agency (ESA) IEC Affiliate Forum New Delhi, India Ethiopia Ethiopia is a country located in the Horn of
More informationINSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
More informationDaily use. Never use alcohol or other solvents to clean any part of the loudspeakers!
BeoLab 6002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-5 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 5: Symmetrical pair/quad cables with transmission characteristics up
More informationTECHNICAL SPECIFICATION FOR PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX) SYSTEM FOR CONNECTION TO PUBLIC SWITCHED TELEPHONE NETWORK (PSTN)
TECHNICAL SPECIFICATION FOR PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX) SYSTEM FOR CONNECTION TO PUBLIC SWITCHED TELEPHONE NETWORK (PSTN) Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia,
More informationBuilding Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
More informationAWG: Cat5e: Cat6: Cat6A:
Some of the terms used in the cable business can be vexing to even the most seasoned folks in the industry. If any of this terminology has ever made you scratch your head, you are certainly not alone.
More informationOperations Manual Blast Chiller
Operations Manual Blast Chiller ADE- 2039-A Page 1 of 14 Contents Page 1 What is the Adande System 3 2 Adande Technology Explained 3 3 EC Declaration of Conformity 4 4 Storage of Product 5 5 Operating
More informationCHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER
000000000!"!##%!"!# & ( ) * + *, ( (-#(. *, )*/.( 0 - % ) ++ )%++) ( ++1 CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER Page 1 / 30 TEQCO597C B. Charging levels and modes Page 4 / 30 C. Plugs /
More informationAustralian/New Zealand Standard
AS/NZS 3200.1.8:2005 (IEC 60601-1-8:2003) AS/NZS 3200.1.8:2005 Australian/New Zealand Standard Medical electrical equipment Part 1.8: General requirements for safety Collateral Standard: General requirements,
More informationHigh School Graduation years 2013, 2014, 2015. Unit/Standard Number
1 Secondary Task List 100 INTRODUCTION TO HVAC 101 Identify HVAC systems. 102 Describe career opportunities in the HVAC profession. 103 Demonstrate awareness of the occupational requirements. 104 Explain
More informationNya och reviderade standarder 2014
Här presenterar vi alla nya och reviderade standarder från år 2014. Standardlistan hittar du alltid på www.intertek.se/om-oss/intertekinfo Nya och reviderade standarder 2014 Standardnummer Namn Standarden
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief
More informationInternational Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
More informationElectrical Contractors Association
Electrical Contractors Association Presents BS 7671 2008: Amendment No 1 BS 7671: 2008 Amendment No 1, 2011 IEE Wiring Regulations Now called IET Wiring Regulations History 1882 first edition of the Wiring
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61400-1 Second edition 1999-02 Wind turbine generator systems Part 1: Safety requirements Aérogénérateurs Partie 1: Spécifications de sécurité IEC 1999 Copyright - all rights
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
More informationIEC/EN 60204-1. Appliance of reference designations on machinery in accordance with ISO/IEC/EN 81346. www.81346.com.
www.81346.com IEC/EN 60204-1 Appliance of reference designations on machinery in accordance with ISO/IEC/EN 81346 September 2010 EU Directive 2006/42/EC on machinery Pick & Place for disc +C1 Pick & Place
More informationCircuit Electrical Testing
Safe Isolation Procedure Circuit Electrical Testing Site Safety Management It is essential from the outset that effective management and control of the system, apparatus and equipment used on site is achieved
More informationEV charging. How EVs are charged? What are the most important international charging standards? Juha Vesa SESKO Development Manager 27.5.
EV charging How EVs are charged? What are the most important international charging standards? Juha Vesa SESKO Development Manager 27.5.2016 1 Content Short survey on standardization What is a standard?
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationThe Disciplines of Engineering Graphics. Introduction
The Need for Electrical/Electronic Graphics in Engineering and Related Curricula School of Engineering Technology Eric Hansberry, Robert Angus, and Thomas Hulbert Northeastern University Boston, Massachusetts
More informationSquare D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationAFE424 SERVICE PARTS
This is the parts list for the AFE. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured
More informationINTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
More informationWhite Paper IK code: Impact protection in line with the IEC 62 262 standard. By Sven Schnautz
White Paper IK code: Impact protection in line with the IEC 62 262 standard By Sven Schnautz Contents List of images... 3 List of tables... 3 List of figures... 3 Introduction... 4 Basic principles...
More informationANSI/IEC 60529-2004. Degrees of Protection Provided by Enclosures (IP Code) (identical national adoption)
ANSI Approval Date November 3, 2004 ANSI/IEC 60529-2004 Degrees of Protection Provided by Enclosures (IP Code) (identical national adoption) Published by: National Electrical Manufacturers Association
More informationAXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
More informationEaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical
Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical Victor Lee Commercial Marketing Manager SEA Eaton Oil & Gas Solution Tech Day 2013 Eaton. All Rights Reserved. Eaton is a leading
More informationSafety of electronic equipment
Standard ECMA-287 2 nd edition - December 2002 International Standardizing Information and Communication Systems Safety of electronic equipment Phone: +41 22 849.60.00 - Fax: +41 22 849.60.01 - URL: http://www.ecma.ch
More informationPerkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet
Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student
More informationHow To Understand The Electrical Power Supply Of A Power Supply System
17 Circuit diagram symbols E 18 CIRCUIT DIAGRAM SYMBOLS electrical network elements three-phase line or cable single-phase line or cable short circuit earth electrode outgoing feeder supply incoming feeder
More informationTables Technical data Standards Explanations Increased safety e
& DATA Tables Technical data Standards Explanations Increased safety e (printed on devices also as "Ex e") 1411 Contents facts & DATA Contents facts & data Cable glands Pg/metric Tables, technical data
More informationCalculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi
Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi One of the most common errors uncovered by product safety engineers stems from manufacturers and designers failing to fully
More informationAcclaim III Recessed Fluorescent Luminaires ATEX
Acclaim III Recessed Fluorescent Luminaires ATEX INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment.
More informationVoltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125
Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated
More informationknow-how Giant in distributing electricity for industry Prisma GK
Prisma GK Giant know-how in distributing electricity for industry Installation system up to 630A for electrical power distribution and circuit control. Prisma GK: technology and innovation for an IP55
More informationThe car safety and more
Making electrotechnology work for you. The car safety and more IEC work in support of the automotive industry and electric cars Scope of IEC work Literally dozens of Technical Committees and thousands
More informationUnit 4: Electricity (Part 2)
Unit 4: Electricity (Part 2) Learning Outcomes Students should be able to: 1. Explain what is meant by power and state its units 2. Discuss the importance of reducing electrical energy wastage 3. State
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationDisclosure to Promote the Right To Information
इ टरन ट म नक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information
More informationTest Code: 8297 / Version 1
Blueprint HVAC Maintenance Technology PA Test Code: 8297 / Version 1 Copyright 2014. All Rights Reserved. General Assessment Information HVAC Maintenance Technology PA Blueprint Contents General Assessment
More informationuser manual smappee monitor
user manual smappee monitor January 2014 (English), version 2.02 2013 smappee NV. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective
More informationTECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS
TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor Darul Ehsan, Malaysia Copyright of SKMM, 2007 FOREWORD
More informationPlease also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
More informationIP DSLAM IDL-2402. Quick Installation Guide
IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...
More informationMICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the
More informationUSE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION
USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION
More informationType-Tested Power Distribution Board 8PT with Rear Busbars. sivacon
Type-Tested Power Distribution Board 8PT with Rear Busbars sivacon The Obvious Solution for Global Challenges SIVACON Type-testing is one of today s important issues for low-voltage technology and will
More informationGuide to the Selection & Use of Residual Current Devices
Guide to the Selection & Use of Residual Current Devices ET214:2005 Edition 1 Electro-Technical Council of Ireland Limited Published by the Electro-Technical Council of Ireland Limited Date of Publication:
More informationInstruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
More informationDear Customer! Thank you for choosing our product.
Dear Customer! Edition 1.4 Thank you for choosing our product. MIDI AMP CONTROLLER MAC-4.4 is an adaptor that enables to control (switch the channels, switch on/off other functions) the amps equipped with
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationDC POWER SUPPLY ALIMENTATION C.C.
DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 82IP-303A0ME E1 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationSEMME3012 Installing marine lighting, alarm, detection and monitoring equipment and systems
Installing marine lighting, alarm, detection and monitoring equipment and Overview This standard identifies the competences you need to install marine lighting, alarm, detection and monitoring, in accordance
More informationNZS 4512:2010. New Zealand Standard. Fire Detection and Alarm Systems in Buildings. Superseding NZS 4512:2003 NZS 4512:2010
New Zealand Standard Fire Detection and Alarm Systems in Buildings Superseding NZS 4512:2003 NZS 4512:2010 NZS 4512:2010 COMMITTEE REPRESENTATION This Standard was prepared under the supervision of the
More informationENVIRONMENTAL TESTING
ENVIRONMENTAL TESTING Mobility Department Environmental Testing Foreword & Introduction Tests Heat - Cold - Climate Page 3 Thermal Shock Page 4 Low - High Pressure Page 4 Vibration Page 5 Mechanical Shock
More informationDakota Energy Cooperative, Inc. POLICY STATEMENT
Dakota Energy Cooperative, Inc. POLICY STATEMENT Subject: Member Owned Small Renewable Energy Policy No. 57 Rate and Interconnection Requirements Issue Date: May 21, 2008 Revised Date: December 16, 2014
More informationIEC specifications for LV assembly switchboards
Technical set IEC specifications for LV assembly switchboards In conformity with IEC 61439-1&2 standard Specifier Guide Introduction Within the IEC 61439 series of standards for low-voltage switchgear
More informationATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61131-2 Third edition 2007-07 Programmable controllers Part 2: Equipment requirements and tests Commission Electrotechnique Internationale International Electrotechnical Commission
More information7 Lighting Technology
7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light
More informationCabling Standards Update 2014
Cabling Standards Update 2014 Dimitris Filippou Technical Director, Ltd. IEEE Member, BICSI Country Chair, ELOT Technical Committee TC93 Member, CENELEC TC215 Delegate of Greek National Committee, CENELEC
More informationRequirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)
Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems) Introduction The purpose of this document is to: 1) provide background information beneficial to specifiers
More informationSUFFOLK COUNTY CODE OF RULES GOVERNING RESTRICTED LICENSED ELECTRICIAN S
SUFFOLK COUNTY CODE OF RULES GOVERNING RESTRICTED LICENSED ELECTRICIAN S Including: 1. Heating, Ventilating and Air Conditioning (HVAC) 2. Irrigation Systems 3. Oil and Gas Burning Equipment 4. Signs and
More informationUNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation.
UNDERSTANDING UNDERSTANDING NFPA 79 By Ned Lloyd and Mike Levesque NFPA-79 is the electrical standard that has been developed by the National Fire Protection Association (NFPA) and is intended to minimize
More informationIce cream maker. Please read the manual fully before using the appliance and keep the manual safe for future reference.
Ice cream maker Please read the manual fully before using the appliance and keep the manual safe for future reference. 1 Contents page Safety guide Page 3 Before first time use Page 5 How to use your ice
More informationELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST
Name of School: OPTIONAL INFORMATION Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST Guidelines: This checklist
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61400-2 Second edition 2006-03 Wind turbines Part 2: Design requirements for small wind turbines This English-language version is derived from the original bilingual publication
More informationMounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More information