IDS HIGH-LEIT NT SCADA System. New Functions - Release 4.19

Size: px
Start display at page:

Download "IDS HIGH-LEIT NT SCADA System. New Functions - Release 4.19"

Transcription

1 IDS HIGH-LEIT NT SCADA System New Functions - Release 4.19

2 SCADA System IDS HIGH-LEIT NT Release 4.19 Release 4.19 of the ID HIGH-LEIT SCADA system combines stability and continuous improvement with innovative functions. Therefore, update customers have their familiar control system with significant improvements in many areas; new customers, on the other hand, acquire a new and cutting-edge SCADA system. The HIGH-LEIT development environment for graphic dialogues and scripting is now fully integrated. Various interface modules for further applications, including grid management (with shift log-function), GIS und EAI have been added to the product. The remodelling and expansion of functionalities for power topology and power grid calculation have been completed with this release. Operating Systems IDS HIGH-LEIT NT 4.19 supports the latest Windows operating systems. Windows 7 (32 und 64 Bit) is used for desktop computers and single-user terminals; Windows 2008 Server R2 (64 Bit) is used for control system-servers and terminal servers. Windows 2008 Server (64 Bit), Windows 2003 Server (32 Bit) and Windows XP professional (32 Bit) are still compatible, whereas the operating systems Windows NT, Windows 2000 as well as Windows VISTA are no longer supported by release Microsoft EXCEL 2010 (32 Bit) and EXCEL 2007 are used for Excel reports and Excel generating lists. IT-Security: HIGH-LEIT NT Server as System Service SCADA systems are no longer isolated applications but rather components of an extensive IT infrastructure. On the one hand, this circumstance simplifies the communication with other departments; on the other hand, however, it also implies increased safety requirements. These safety requirements are compiled in a whitepaper by the German Federal Association of the Energy and Water Industry (BDEW). To fulfil one of the central requirements of the BDEW whitepaper on IT security, the HIGH- LEIT NT server (release 4.19 and later) is designed as a windows system service which becomes automatically available during server boot-up. Until now, an operator with Windows administration rights had to be logged onto the server to start the control system server. In the new constellation, this is no longer necessary, thereby preventing almost entirely the inadvertent or wilful interference with the operating system by unauthorized persons.

3 Shift log Shift Log A shift log which accurately and concisely records all events in the course of a shift is now available as an optional function. All important events are recorded automatically or can be entered manually. The necessary information for the subsequent shift is compiled in a transfer report and can be saved revision-proof in a local directory or in a network access-enabled directory. The shift log function is part of the ACOS NMS Network Management Suite. ACOS NMS can be upgraded to a complete network management tool by means of further components. Specific functions are available for asset management and maintenance, for outage management and for order and workforce management. New Action Dialogues All HIGH-LEIT action dialogues have been completely revised and the operating logic is now more intuitive. From now on, interlocking checks, for example, (command interlocks, local,...) are checked before their execution during the output of a command. If a check fails, the action will be terminated with a status signal. The adjustment dialogue has been supplemented by input fields where the operator on site and the time on site can be entered. New command dialogue

4 Similar to release 4.18, all action dialogues can be adapted by means of a script editor (cf. VBA for MS Excel), allowing for simple, project-specific customizing. Adaptation via scripting can be done during start-up and is available even in the event of a release change. New Topology The topology module has been continuously improved with release 4.19, providing, amongst others, extended diagnostics and a more accurate representation of the power grid through the differentiation and nomination of single equipment types and the corresponding busbar sections. Thanks to the improved designation, it is possible to specify interlocking conditions more precisely. Load-Flow Calculation based on FGH INTEGRAL The module Power Grid Calculation has been completely updated as well and is now based on the calculation engine INTEGRAL developed by the German Forschungsgemeinschaft für Elektrische Anlagen und Stromwirtschaft e.v. (FGH). The new load-flow calculation is based on a convergence-safe Newton-Raphson algorithm. A reliable convergence of the load-flow calculation is an important prerequisite for efficient network management. Therefore, various measures have been implemented to ensure excellent convergence behaviour. For instance, coupled busbars, which are frequently connected to each other via very low impedances, are treated as one node in the actual calculation. Typified Switching Sequences Depending on the selected power line, the system automatically provides the available switching operations for selection and creates, at the touch of a button, the appropriate switching sequence, e.g. for line disconnection safety isolation and grounding fault isolation supply restoration busbar switchover in several outgoing circuits Preview Function for Switching Sequences In addition to test runs for switching sequences, it is now possible for the operator to take an advance look ( preview ) at the status of the network following the termination of a switching sequence. Visualization of load-flow calculation Furthermore, the latest techniques for shortcircuit current calculation based on the guidelines of IEC have been included. The HIGH-LEIT release 4.19 includes all correction methods of these norms. The calculation of short-circuit currents in HIGH-LEIT NT 4.19 takes place for all nodes according to the Takahashi method. This method is highly suitable to obtain a quick overview of shortcircuit currents in the entire network. The four fault types described in the VDE norm (3- pole, 2-pole and 1-pole errors, as well as 2- pole errors with ground contact) are calcu-

5 lated simultaneously, making the results of each fault type available for visualization. In addition to the calculation of individual errors at each node, HIGH-LEIT also enables a more precise analysis of a given fault. Through specifying a fault location, it is possible to calculate various different short-circuit situations. In such cases, voltages and currents can be determined across the entire network. In the context of the switch permit check, the system carries out overload, voltage limit and short-circuit strength checks prior to the execution of switching operations. In the event of limit violations, a warning signal is emitted and possible overloads as well as overvoltages and low voltages are displayed. Load flow- and short-circuit current calculations are available in the simulation mode, thereby enabling the modelling e.g. of modulus controls of transformers. Integration of GISMobil Within the context of Smart Metering, increasing amounts of information from the power grid are being measured and transmitted to the SCADA system. Through the integration of a GIS system containing network data, and through the interaction between GIS and the SCADA system, the current supply status of the l.v. network can be visualized individually for each building, thereby enabling the operator, for instance, to determine which service connections are affected by a fault in the m.v.- or l.v. power line. In a first step, the GISMobil system (from Infograph) was integrated into HIGH-LEIT. The interface allows, on the one hand, the transfer of switch setting changes from the medium voltage network to GISMobil and, on the other hand, the activation of a GISMobil client via a process display. Data exchange takes place via the EAI system ACOS X4. Since release 4.18, HIGH- LEIT has been integrated in the companywide data and process environment by means of this EAI system. The ACOS X4 interface also enables the integration of further GIS systems. Example of the integration of a GIS system into HIGH-LEIT NT - left: overview of m.v. network, middle: detail of m.v. network, right: the same detail with l.v. topology in GISMobil

6 Archiving Since HIGH-LEIT NT release 4.18, eventcontrolled archives (EC archives) can be parameterized instead of seconds archives. This has the following advantages: on the one hand, memory space is saved during archiving, because archived values will be saved in the short-term archive area only if this value changes; on the other hand, this method ensures that there is no loss of data even with frequently changing process values. In the current release, EC archives have become even more user-friendly: EC Archive Statistics Frequently changing values of the EC archive lead to a huge increase in the size of EC archives. Therefore, a possibility has been found to determine which objects put a particular strain on the EC archive through frequent writing. Evaluation takes place via a new protocol type - the EC archive statistics. These statistics have the additional benefit of enabling the detection of any possible faults in the parameterization of the RTU. EC archive statistics Virtual Extreme Values for Arithmetic Values Flexible extreme-value archives can be created on the basis of EC archives. Instead of one single daily minimum resp. maximum value, it is now possible to condense and evaluate extreme values for different time patterns (e.g. lowest quarter-hour total as daily minimum). This function is also available for arithmetic values with the new release. Virtual extreme values Chronologically Correct Archiving of delayed IEC Telegrams Up to now, changes in process values, whose IEC telegrams arrived in the control system with a significant delay, were invariably rejected by the control system. In some cases, however, it is not wholly possible to avoid a delayed transmission of telegrams (e.g. in the case of process values which, as a rule, are transmitted only a few times every day). From release 4.19 onwards, HIGH-LEIT NT is capable of processing this type of IEC telegrams. Measured values and counter values are sorted in the minutes archive in their correct chronological order and event signals are recorded in the event log, thereby enabling e.g. the processing of process values from the EP30 data logger from Erwin Peters Systemtechnik, a subsidiary of IDS GmbH. In this application, however, no processing of process values (such as limit monitoring) takes place. The user can decide individually for each RTU how such cases shall be detected. For this purpose, we recommend to set a separate IEC cause of transmission in the private domain.

7 Further Innovations HIGH-LEIT NT s scope of functions has been rounded off by a number of minor expansions: Adaptable Event Report Filters Filters for event log reports have been made more flexible. Until now, it was necessary to store all criteria in the filter, and only the evaluation period could be specified by the operator during a call. The remaining criteria could only be changed by operators with the necessary access authorization. From now on, it is possible to use the parameter operator input as a filter criterion. This parameter can be specified by the operator when calling up the filter. shows the selected event signal at the centre of the static event log display. Archiving Tag for Limit Violation A tag in the archive marking a specific value indicates that that value was saved while a violation of warning or fault limits took place. If that value is displayed in a diagram, it is possible to change the colour of this trend section, and the corresponding tag appears in the curve description line. Automatic Dispatch of Reports via Reports created via the command list function can now be sent to a stored address as pdf-file. Advanced Review Function Event report with filter definition dialogue Leap to the Selected Signal The Review functionality enables the operator to analyze processes from the past by playing a sequence of archived process values like a video clip. So far, minute archives were used for this function. Through the integration of EC archives into the Review function, the operator is now able to generate historic analyses for all process values, with the finest possible resolution. When leaving the event display filter, the event display is set again to a dynamic status. This might cause an event that was being searched for by means of the event log filter to be no longer within the visible range of the event log display. So far, operators had to memorize the time of an event and enter it as a search parameter. Instead of this somewhat inconvenient method, it is now possible to select a message before switching off the filter. Thus, when the filter is switched off, the display is automatically arranged so that it

8 Advanced Connectivity The Connectivity function has also seen some major improvements: If a message is registered as the checkback signal of a command, the operator can use the command Go To... Event Log from the pop-up menu to filter the event log for the commands belonging to an event signal or for the checkback signals belonging to a command. Also, the Connectivity function is now available for group commands, switching programs and switching sequences. It is possible to carry out a filtering process according to a group command (switching program, switching sequence) via the command Go To... Event Log (pop-up command) and to branch out to the appropriate generating dialogue. Stations in a Line with different Gateways If a telecontrol line included several stations with different gateways (e.g. several GPRS stations with different gateway addresses in an IP subnetwork), users were faced with the problem that the SCADA system did not automatically assign the lines to the stations because the IP-address and subnet mask could only be entered once for each telecontrol line. This feature has been changed for the current release, thereby enabling the user to store the gateways at the outstation. If no specific gateway is parameterized for an outstation, the gateway will be automatically taken over from the line. jet Release: September 2010 We reserve the right for technical modifications IDS GmbH Nobelstraße 18 D Ettlingen Postfach D Ettlingen Germany Tel Fax info@ids.de Internet: GPM e

A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES

A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES A Roberts, T Berry, W D Wilson Schneider Electric Ltd, UK SYNOPSIS This paper describes the features of a modern Distribution

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

How To Protect Your Power Supply From Dangerous Currents And Voltages

How To Protect Your Power Supply From Dangerous Currents And Voltages ids ACOS 300 Protection equipment for medium and highvoltage grids ACOS 300 Protection Devices Already minor incidents, such as branches dropping on overhead lines or underground cables damaged by construction

More information

Industrial IT Ó Melody Composer

Industrial IT Ó Melody Composer Overview Industrial IT Ó Melody Composer Features and Benefits Support of concurrent engineering for Control Systems Operation on Windows NT and Windows 2000 Multiple client/server architecture Off-Line

More information

Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template

Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template Application Note Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template Author Jens Baumeister jens.baumeister@omicron.at Date

More information

Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111

Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111 , GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the

More information

Complete fleet management package for Qualitrol Information Products

Complete fleet management package for Qualitrol Information Products + iq Master Station Configuration, collection and analysis platform Complete fleet management package for Qualitrol Information Products Scalable client-server solution Advanced Record Analysis diagnostics

More information

04 / 2012. Panel Design Configurator The modular planning software for low voltage distribution systems

04 / 2012. Panel Design Configurator The modular planning software for low voltage distribution systems 04 / 2012 Panel Design Configurator The modular planning software for low voltage distribution systems Panel Design Configurator an all-round solution for project planning Panel Design Configurator is

More information

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5 SIMATIC WinCC V7.0 SIMATIC WinCC V7.0 Printout of the Online Help 1 Welcome 2 Icons 3 Creating a project 4 Configure communication 5 Configuring the Process Screens 6 Archiving and displaying values 7

More information

ProSafe Plus Switch Utility

ProSafe Plus Switch Utility ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA December 2012 202-10524-05 NETGEAR, Inc. All rights reserved No part of this publication maybe reproduced, transmitted,

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Multi-User Systems 1 ArchiveServer 2 SIMATIC HMI WinCC V7.0 SP1 File Server 3 WinCC ServiceMode 4 Redundant Systems 5 System Manual Print of the Online Help 11/2008 Legal information Warning notice system

More information

ProSafe Plus Switch Utility

ProSafe Plus Switch Utility ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA September 2010 202-10524-03 v1.0 ProSafe Plus Switch Utility User Guide 2010 NETGEAR, Inc. All rights reserved. No

More information

EBERSPÄCHER ELECTRONICS automotive bus systems. solutions for network analysis

EBERSPÄCHER ELECTRONICS automotive bus systems. solutions for network analysis EBERSPÄCHER ELECTRONICS automotive bus systems solutions for network analysis DRIVING THE MOBILITY OF TOMORROW 2 AUTOmotive bus systems System Overview Analyzing Networks in all Development Phases Control

More information

Isolated-Parallel UPS Configuration

Isolated-Parallel UPS Configuration Isolated-Parallel UPS Configuration 1 Inhalt 1 Introduction... 4 2 IP systems configuration... 6 3 Projects... 17 4 Conclusions... 17 2 Abstract The isolated-parallel UPS configuration has become well

More information

YZP 480...495: SAUTER Vision Center

YZP 480...495: SAUTER Vision Center YZP 480...495: SAUTER Vision Center SAUTER Vision Center 3.0 - latest-generation modular building management software for energy-efficient buildings The SAUTER Vision Center (SVC) is a web-based building

More information

energized: zenon energy edition. reliable supervision and efficient control of energy plants, distribution networks and substations.

energized: zenon energy edition. reliable supervision and efficient control of energy plants, distribution networks and substations. energized: zenon energy edition. reliable supervision and efficient control of energy plants, distribution networks and substations. introduction. minimize expense, increase productivity. satisfied customers

More information

S m a r t M a s t e B T E C O R P O R A T I O N USER MANUAL

S m a r t M a s t e B T E C O R P O R A T I O N USER MANUAL S m a r t M a s t e rtm 2014 B T E C O R P O R A T I O N USER MANUAL S m a r t M a s t e r T M 2 0 1 4 U s e r M a n u a l P a g e 1 o f 2 3 Contents Contents...1 Introduction...2 Audience...2 SmartMaster

More information

PNOZmulti Configurator V8.1.1

PNOZmulti Configurator V8.1.1 General 1000 PNOZmulti 1.1 1100 General 1- ][Allgemein Configurator V8.1.1 This document contains important information, which must be noted. This document also contains details of the changes made in

More information

SPPA-T3000 Control System The Benchmark in Controls

SPPA-T3000 Control System The Benchmark in Controls Instrumentation, Controls & Electrical SPPA-T3000 Control System The Benchmark in Controls Siemens Power & Process Automation Answers for energy. The benchmark for Distributed Control Systems Developed

More information

Updating to Test Universe 3.0. What s new?

Updating to Test Universe 3.0. What s new? Updating to Test Universe 3.0 What s new? Test Universe 3.0 An overview of the new features This brochure provides you with information on the following new features in our Test Universe software for

More information

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories: Filed: September 0, 00 EB-00-0 Tab Schedule Page of OPERATIONS CAPITAL.0 INTRODUCTION Operations Capital funds enhancements and replacements to the facilities required to operate the Hydro One Transmission

More information

Flexible, Scalable and independent HMI software for today s world

Flexible, Scalable and independent HMI software for today s world Simple, powerful and independent HMI software Flexible, Scalable and independent HMI software for today s world All the experience and technology of Progea in SCADA supervision software is now available

More information

IDDERO HOME SERVER. Quick start guide. www.iddero.com 150302-02

IDDERO HOME SERVER. Quick start guide. www.iddero.com 150302-02 IDDERO HOME SERVER Quick start guide www.iddero.com 150302-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 IDDERO CONFIGURATION SOFTWARE... 3 2.1 Installation and First Steps...3 3 IDDERO HOME SERVER CONFIGURATION...

More information

Alert ALARM MANAGEMENT

Alert ALARM MANAGEMENT by Alert ALARM MANAGEMENT Alert To inform and to alert Alert is able to treat alarms or intervention demand coming from different sources: Supervisor software (SCADA), via DDE, OPC or dedicated interface

More information

Software User Guide UG-461

Software User Guide UG-461 Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment

More information

Virtual CD v10. Network Management Server Manual. H+H Software GmbH

Virtual CD v10. Network Management Server Manual. H+H Software GmbH Virtual CD v10 Network Management Server Manual H+H Software GmbH Table of Contents Table of Contents Introduction 1 Legal Notices... 2 What Virtual CD NMS can do for you... 3 New Features in Virtual

More information

S7 for Windows S7-300/400

S7 for Windows S7-300/400 S7 for Windows S7-300/400 A Programming System for the Siemens S7 300 / 400 PLC s IBHsoftec has an efficient and straight-forward programming system for the Simatic S7-300 and ern controller concept can

More information

CAN REMOTE I/O module. base device GEL 89100

CAN REMOTE I/O module. base device GEL 89100 CAN REMOTE I/O module Base device GEL 9100 with and modules Technical mation Version 0.01 CAN REMOTE I/O module base device GEL 9100 digital and modules or analogue and modules CAN-T-connector 24 V Internet:

More information

Documentation. M-Bus 130-mbx

Documentation. M-Bus 130-mbx Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out

More information

Dell OpenManage Mobile Version 1.4 User s Guide (Android)

Dell OpenManage Mobile Version 1.4 User s Guide (Android) Dell OpenManage Mobile Version 1.4 User s Guide (Android) Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION

More information

Network Manager Training. Course Descriptions NM5. Catalog

Network Manager Training. Course Descriptions NM5. Catalog Copyright 2014 ABB. All rights reserved. Network Manager Training Course Descriptions NM5 Catalog Based on Prep. PS/PSSW/ / 2015-03-16 Appr. / External doc. no. Project Doc. kind Doc. Plan des. Ref. des.

More information

Getting started with M-Files Client Software

Getting started with M-Files Client Software Getting started with M-Files Client Software This guide helps you to get up to speed with M-Files Client software. You can use the client software to access onpremise and cloud based M-Files servers. Getting

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW I/A Series SOFTWARE Product Specifications Logo I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 The I/A Series Intelligent SCADA Platform takes the traditional SCADA Master Station to a new

More information

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS APPLICATION NOTE Contents The DMP Software Family... 1 Stand-Alone Link Software... 1 Add-on Modules for Link Software... 1 System Link End-User Panel Management Software... 2 Simple Registration and Activation...

More information

Portfolio of Products. Integrated Engineering Environment. Overview

Portfolio of Products. Integrated Engineering Environment. Overview Portfolio of Products Integrated Engineering Environment Overview Automation Studio is an all-in-one easy-to-use software that provides an open, productive and flexible engineering environment for the

More information

IntesisBox ASCII Server - LON

IntesisBox ASCII Server - LON IntesisBox ASCII Server - LON Gateway for integration of LON devices into ASCII enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi

More information

Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA 95134 USA. November 2010 202-10685-01 v1.0

Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA 95134 USA. November 2010 202-10685-01 v1.0 Smart Control Center User Guide 350 East Plumeria Drive San Jose, CA 95134 USA November 2010 202-10685-01 v1.0 2010 NETGEAR, Inc. All rights reserved. No part of this publication may be reproduced, transmitted,

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

User Manual. Software SmartGUI. Dallmeier electronic GmbH & Co.KG. DK 200.004.000 GB / Rev. 1.2.6 / 031222

User Manual. Software SmartGUI. Dallmeier electronic GmbH & Co.KG. DK 200.004.000 GB / Rev. 1.2.6 / 031222 User Manual Software SmartGUI 1 DK 200.004.000 GB / Rev. 1.2.6 / 031222 Software SmartGUI Copyright All rights reserved. No part of this document may be copied, photocopied, reproduced, translated, transferred

More information

ProSAFE 8-Port and 16-Port Gigabit Click Switch

ProSAFE 8-Port and 16-Port Gigabit Click Switch ProSAFE 8-Port and 16-Port Gigabit Click Switch Model GSS108E and GSS116E User Manual March 2015 202-11520-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products.

More information

Axapta Object Server MICROSOFT BUSINESS SOLUTIONS AXAPTA

Axapta Object Server MICROSOFT BUSINESS SOLUTIONS AXAPTA MICROSOFT BUSINESS SOLUTIONS AXAPTA Axapta Object Server Microsoft Business Solutions Axapta Object Server minimises bandwidth requirements and ensures easy, efficient and homogeneous client deployment.

More information

friendlyway composer network services server

friendlyway composer network services server HelpAndManual_illegal_keygen friendlyway composer network services server User manual Contents I Contents Welcome 1 Why composer network services? 2 Support 3 Introduction 4... 4 Getting started with

More information

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4 Present sample project 1 HMI configuration 2 SIMATIC Getting Started Insert HMI device from libraries 3 Configuring HMI connection 4 Configuring system diagnostics 5 Simulating an HMI device 6 05/2014

More information

StruxureWare Power Monitoring 7.0.1

StruxureWare Power Monitoring 7.0.1 StruxureWare Power Monitoring 7.0.1 Installation Guide 7EN02-0308-01 07/2012 Contents Safety information 5 Introduction 7 Summary of topics in this guide 7 Supported operating systems and SQL Server editions

More information

ugrid Testbed. Rein in microgrid complexity. With ease.

ugrid Testbed. Rein in microgrid complexity. With ease. ugrid Testbed. Rein in microgrid complexity. With ease. Outsmart the microgrid. ugrid Testbed Ultimate test solution for microgrid control system verification What is a microgrid? Microgrid is a collection

More information

Instruction Manual Service Program ULTRA-PROG-IR

Instruction Manual Service Program ULTRA-PROG-IR Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...

More information

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700 Tel: +90-216 466 84 60 Fax: +90-216 364 65 65 datakom@datakom.com.tr http://www.datakom.com.tr APPLICATION NOTE Ethernet Configuration Guide for D-500 D-700 PRODUCTS AFFECTED: D-500 / D-700 WRITTEN BY:

More information

Bitrix Site Manager 4.1. User Guide

Bitrix Site Manager 4.1. User Guide Bitrix Site Manager 4.1 User Guide 2 Contents REGISTRATION AND AUTHORISATION...3 SITE SECTIONS...5 Creating a section...6 Changing the section properties...8 SITE PAGES...9 Creating a page...10 Editing

More information

Running a Load Flow Analysis

Running a Load Flow Analysis Running a Load Flow Analysis The purpose of this tutorial is to introduce the Load Flow Analysis module, and provide instructions on how to run a load flow study. In addition, an example of how to regulate

More information

IFS-8000 V2.0 INFORMATION FUSION SYSTEM

IFS-8000 V2.0 INFORMATION FUSION SYSTEM IFS-8000 V2.0 INFORMATION FUSION SYSTEM IFS-8000 V2.0 Overview IFS-8000 v2.0 is a flexible, scalable and modular IT system to support the processes of aggregation of information from intercepts to intelligence

More information

Please check www.milestonesys.com for updates to make sure you install the most recent version of our software.

Please check www.milestonesys.com for updates to make sure you install the most recent version of our software. Guide Contents Dear Milestone Customer, With the purchase of Milestone XProtect Central you have chosen a very powerful central monitoring solution, providing instant overview of any number of Milestone

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

CONTROL MICROSYSTEMS DNP3. User and Reference Manual

CONTROL MICROSYSTEMS DNP3. User and Reference Manual DNP3 User and Reference Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support: 888-226-6876

More information

SCADA/HMI MOVICON TRAINING COURSE PROGRAM

SCADA/HMI MOVICON TRAINING COURSE PROGRAM SCADA/HMI MOVICON TRAINING COURSE PROGRAM The Movicon training program includes the following courses: Basic Training Course: 1 day course at Progea head offices or authorized center. On location at client

More information

Privacy Policy Version 1.0, 1 st of May 2016

Privacy Policy Version 1.0, 1 st of May 2016 Privacy Policy Version 1.0, 1 st of May 2016 THIS PRIVACY POLICY APPLIES TO PERSONAL INFORMATION COLLECTED BY GOCIETY SOLUTIONS FROM USERS OF THE GOCIETY SOLUTIONS APPLICATIONS (GoLivePhone and GoLiveAssist)

More information

Citrix Application Streaming. Universal Application Packaging and Delivery Breaking Away from Traditional IT

Citrix Application Streaming. Universal Application Packaging and Delivery Breaking Away from Traditional IT Citrix Application Streaming Universal Application Packaging and Delivery Breaking Away from Traditional IT Application Packaging Application Delivery to Endpoint Devices Application Isolation Mode Automatic

More information

11.1. Performance Monitoring

11.1. Performance Monitoring 11.1. Performance Monitoring Windows Reliability and Performance Monitor combines the functionality of the following tools that were previously only available as stand alone: Performance Logs and Alerts

More information

Nero MediaStreaming for MCE Manual

Nero MediaStreaming for MCE Manual Nero MediaStreaming for MCE Manual Nero AG Copyright and Trademark Information This manual and all its contents are protected by copyright and are the property of Nero AG. All rights reserved. This manual

More information

Administrator s Guide

Administrator s Guide Attachment Save for Exchange Administrator s Guide document version 1.8 MAPILab, December 2015 Table of contents Intro... 3 1. Product Overview... 4 2. Product Architecture and Basic Concepts... 4 3. System

More information

SPAMfighter Mail Gateway

SPAMfighter Mail Gateway SPAMfighter Mail Gateway User Manual Copyright (c) 2009 SPAMfighter ApS Revised 2009-05-19 1 Table of contents 1. Introduction...3 2. Basic idea...4 2.1 Detect-and-remove...4 2.2 Power-through-simplicity...4

More information

DME4 V1.23 (06-1999) V1.30 (06-2000) V1.31 (04-2001) V1.32 (09-2001) V1.33 (03-2002) V1.34 (06-2003) V1.35 (05-2004) V2.00 (12-2005) V2.

DME4 V1.23 (06-1999) V1.30 (06-2000) V1.31 (04-2001) V1.32 (09-2001) V1.33 (03-2002) V1.34 (06-2003) V1.35 (05-2004) V2.00 (12-2005) V2. DME4 V1.23 (06-1999) - Correction of unfounded error message 'No measurements configured' when reading measurements from DME440 (MODBUS) if special measurands hadn't been selected to be calculated. - Correction

More information

SCADA Questions and Answers

SCADA Questions and Answers SCADA Questions and Answers By Dr. Jay Park SCADA System Evaluation Questions Revision 4, October 1, 2007 Table of Contents SCADA System Evaluation Questions... 1 Revision 4, October 1, 2007... 1 Architecture...

More information

Remote PC Guide for Standalone PC Implementation

Remote PC Guide for Standalone PC Implementation Remote PC Guide for Standalone PC Implementation Updated: 2007-01-22 The guide covers features available in NETLAB+ version 3.6.1 and later. IMPORTANT Standalone PC implementation is no longer recommended.

More information

PSS SINCAL efficient planning software for electricity and pipe networks. Siemens PTI Software Solutions. Answers for energy.

PSS SINCAL efficient planning software for electricity and pipe networks. Siemens PTI Software Solutions. Answers for energy. PSS SINCAL efficient planning software for electricity and pipe networks Siemens PTI Software Solutions Answers for energy. PSS SINCAL efficient planning of utility & industry networks Comprehensive network

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

Automation software Concept V2.6 The flexible IEC 61131-3 development environment to optimize PLC performance

Automation software Concept V2.6 The flexible IEC 61131-3 development environment to optimize PLC performance Automation software Concept V2.6 The flexible IEC 61131-3 development environment to optimize PLC performance Simply Smart! Leveraging ingenuity and intelligence for ease of use. Programming software that

More information

Course Syllabus. Fundamentals of Windows Server 2008 Network and Applications Infrastructure. Key Data. Audience. Prerequisites. At Course Completion

Course Syllabus. Fundamentals of Windows Server 2008 Network and Applications Infrastructure. Key Data. Audience. Prerequisites. At Course Completion Key Data Product #: 3380 Course #: 6420A Number of Days: 5 Format: Certification Exams: Instructor-Led None This course syllabus should be used to determine whether the course is appropriate for the students,

More information

IQ MORE / IQ MORE Professional

IQ MORE / IQ MORE Professional IQ MORE / IQ MORE Professional Version 5 Manual APIS Informationstechnologien GmbH The information contained in this document may be changed without advance notice and represents no obligation on the part

More information

Semaphore T BOX Applications in Data Center Facilities

Semaphore T BOX Applications in Data Center Facilities Semaphore T BOX Applications in Data Center Facilities Introduction Data centers must reliably provide 24/7/365 operation. For automation and monitoring of the facility, use of a rugged, reliable RTU is

More information

Network Administrator s Guide and Getting Started with Autodesk Ecotect Analysis

Network Administrator s Guide and Getting Started with Autodesk Ecotect Analysis Autodesk Ecotect Analysis 2011 Network Administrator s Guide and Getting Started with Autodesk Ecotect Analysis This document describes how to install and activate Autodesk Ecotect Analysis 2011 software

More information

Administrator s Guide

Administrator s Guide MAPILab Disclaimers for Exchange Administrator s Guide document version 1.8 MAPILab, December 2015 Table of contents Intro... 3 1. Product Overview... 4 2. Product Architecture and Basic Concepts... 4

More information

Using Avaya Aura Messaging

Using Avaya Aura Messaging Using Avaya Aura Messaging Release 6.3.2 Issue 1 December 2014 Contents Chapter 1: Getting Started... 4 Messaging overview... 4 Prerequisites... 4 Accessing your mailbox from any phone... 4 Accessing the

More information

KASPERSKY LAB. Kaspersky Administration Kit version 6.0. Administrator s manual

KASPERSKY LAB. Kaspersky Administration Kit version 6.0. Administrator s manual KASPERSKY LAB Kaspersky Administration Kit version 6.0 Administrator s manual KASPERSKY ADMINISTRATION KIT VERSION 6.0 Administrator s manual Kaspersky Lab Visit our website: http://www.kaspersky.com/

More information

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master

More information

ABB i-bus EIB Logic Module LM/S 1.1

ABB i-bus EIB Logic Module LM/S 1.1 Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...

More information

Project management integrated into Outlook

Project management integrated into Outlook Project management integrated into Outlook InLoox PM 7.x off-line operation An InLoox Whitepaper Published: October 2011 Copyright: 2011 InLoox GmbH. You can find up-to-date information at http://www.inloox.com

More information

Design of Strong-motion Monitoring System for Dam-reservoir D s e i s gn of Stro r ng-mo m tion Monito t ri r ng Syst s em

Design of Strong-motion Monitoring System for Dam-reservoir D s e i s gn of Stro r ng-mo m tion Monito t ri r ng Syst s em Design of Strong-motion Monitoring System for Dam-reservo eservoir Li Caihua Li Xiaojun Institute of Engineering Mechanics, China Earthquake Administration China Harbin 150080 Abstract: One strong-motion

More information

Network Manager Training Course Descriptions NM6

Network Manager Training Course Descriptions NM6 Copyright 2015 ABB. All rights reserved. Network Manager Training Course Descriptions NM6 Catalogue We reserve all rights in this document and in the information therein. Reproduction,use or disclosure

More information

IEC 61850 SCL - MORE THAN INTEROPERABLE DATA EXCHANGE BETWEEN ENGINEERING TOOLS

IEC 61850 SCL - MORE THAN INTEROPERABLE DATA EXCHANGE BETWEEN ENGINEERING TOOLS IEC 61850 SCL - MORE THAN INTEROPERABLE DATA EXCHANGE BETWEEN ENGINEERING TOOLS Wolfgang Wimmer ABB Baden, Switzerland wolfgang.wimmer@ch.abb.com Abstract The IEC 61850 SCL language for Substation Configuration

More information

Intel Active Management Technology with System Defense Feature Quick Start Guide

Intel Active Management Technology with System Defense Feature Quick Start Guide Intel Active Management Technology with System Defense Feature Quick Start Guide Introduction...3 Basic Functions... 3 System Requirements... 3 Configuring the Client System...4 Intel Management Engine

More information

Products that are referred to in this document may be trademarks and/or registered trademarks of the respective owners.

Products that are referred to in this document may be trademarks and/or registered trademarks of the respective owners. 2015 GEOVAP, spol. s r. o. All rights reserved. GEOVAP, spol. s r. o. Cechovo nabrezi 1790 530 03 Pardubice Czech Republic +420 466 024 618 http://www.geovap.cz Products that are referred to in this document

More information

DOE Wind Consortium Project. Wind Energy Research and Development. Jay Giri. IIT, Chicago July 20 th, 2011. Jay.giri@alstom.com. Copyright ALSTOM Grid

DOE Wind Consortium Project. Wind Energy Research and Development. Jay Giri. IIT, Chicago July 20 th, 2011. Jay.giri@alstom.com. Copyright ALSTOM Grid DOE Wind Consortium Project Wind Energy Research and Development IIT, Chicago July 20 th, 2011 Jay Giri Jay.giri@alstom.com Possible Impacts of Wind Power on Grid Operations (Source: IEA Wind Task 25,

More information

Job Scheduler User Guide IGSS Version 11.0

Job Scheduler User Guide IGSS Version 11.0 Job Scheduler User Guide IGSS Version 11.0 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained therein.

More information

Cisco Change Management: Best Practices White Paper

Cisco Change Management: Best Practices White Paper Table of Contents Change Management: Best Practices White Paper...1 Introduction...1 Critical Steps for Creating a Change Management Process...1 Planning for Change...1 Managing Change...1 High Level Process

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

DIGICLIENT 8.0 Remote Agent Software

DIGICLIENT 8.0 Remote Agent Software DIGICLIENT 8.0 Remote Agent Software MODEL: D17800 Series Instruction Manual English Version 1.0 Copyright 2007 Digimerge Technologies Inc Table of Contents Table of Contents About the DigiClient 8.0...

More information

UNLOCK YOUR IEC 61850 TESTING EXCELLENCE

UNLOCK YOUR IEC 61850 TESTING EXCELLENCE IMPROVE EFFICIENCY TEST WITH CONFIDENCE OF KNOW-HOW LEARN AND EXPAND YOUR IEC 61850 SKILLS MASTER YOUR NETWORK KNOWLEDGE GENERATE TEST RESULTS UNLOCK YOUR IEC 61850 TESTING EXCELLENCE Connect To & Read

More information

SNMP Web Management. User s Manual For SNMP Web Card/Box

SNMP Web Management. User s Manual For SNMP Web Card/Box SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...

More information

IEC 61850 in ZX Gas-insulated medium voltage switchgear

IEC 61850 in ZX Gas-insulated medium voltage switchgear IEC 61850 in ZX Gas-insulated medium voltage switchgear IEC 61850 in ZX Just as the supply of electrical power is becoming more and more important in a networked world, demands for the integration of electrical

More information

I-Fax (Internet Fax) 1: Basic Overview. 2: Benefits to the customer. Machines included:

I-Fax (Internet Fax) 1: Basic Overview. 2: Benefits to the customer. Machines included: (Internet Fax) Machines included: HL-4040CN HL-4050CDN HL-4070CDW DCP-9040CN DCP-9045CDN MFC-9440CN MFC-9840CDW DCP-8060 DCP-8065DN MFC-8460N MFC-8860DN MFC-8870DW Contents 1) Overview 2) Benefits to the

More information

ABB solar inverters. User s manual ABB Remote monitoring portal

ABB solar inverters. User s manual ABB Remote monitoring portal ABB solar inverters User s manual ABB Remote monitoring portal List of related manuals Title ABB Remote monitoring portal User s manual NETA-01 Ethernet adapter module User s manual Code (English) 3AUA0000098904

More information

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev. Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of

More information

Cisco Unified Workforce Optimization

Cisco Unified Workforce Optimization Cisco Unified Workforce Optimization Desktop Requirements Guide Version 10.5 First Published: June 18, 2014 Last Updated: March 6, 2015 THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS

More information

User Guide. Version 3.2. Copyright 2002-2009 Snow Software AB. All rights reserved.

User Guide. Version 3.2. Copyright 2002-2009 Snow Software AB. All rights reserved. Version 3.2 User Guide Copyright 2002-2009 Snow Software AB. All rights reserved. This manual and computer program is protected by copyright law and international treaties. Unauthorized reproduction or

More information

M-series Virtual I/O Module 2

M-series Virtual I/O Module 2 DeltaV Distributed Control System Product Data Sheet M-series Virtual I/O Module 2 Non-intrusive DeltaV I/O simulation Powerful integration solution Easy to use Modular, flexible packaging The M-series

More information

2012 uptimedevices.com

2012 uptimedevices.com 2012 uptimedevices.com Contents Product Overview...3 Installation...4 Web Interface Orientation...5 Web Interface (Login Screen)...6 Summary Screen...7 Sensors Screen...8 Sensor Names...9 Graph...10 Alerts

More information

Manual Password Depot Server 8

Manual Password Depot Server 8 Manual Password Depot Server 8 Table of Contents Introduction 4 Installation and running 6 Installation as Windows service or as Windows application... 6 Control Panel... 6 Control Panel 8 Control Panel...

More information

ADMS(Advanced Distribution Management System ) in Smart Grid

ADMS(Advanced Distribution Management System ) in Smart Grid ADMS(Advanced Distribution Management System ) in Smart Grid 柯 佾 寬 博 士 Yi-Kuan Ke, Ph.D. 2014/03/28 Smart Grid Solution Smart Grid Solution Overview Smart Grid Solutions Smart Network Operation - Distribution

More information

Deltek Touch Time & Expense for GovCon. User Guide for Triumph

Deltek Touch Time & Expense for GovCon. User Guide for Triumph Deltek Touch Time & Expense for GovCon User Guide for Triumph November 25, 2014 While Deltek has attempted to verify that the information in this document is accurate and complete, some typographical or

More information