Question Shall the Tender include installation of the central server application on a redundant server?
|
|
- Arthur Terry
- 8 years ago
- Views:
Transcription
1 s and answers regarding the Invitation for Tender for a national gamma monitoring system in Sweden s and answers published Will alternative tenders from the same Tenderer be considered? No, only the Tender that fulfils all financial, economical and technical requirements and has the lowest price will be selected for further comparison with Tenders from other Tenderers. Can a Tenderer offer different types of sensors and thereby provide an opportunity for the Swedish Radiation Safety Authority to select the one that is best suited? No, only the Tender that fulfils all financial, economical and technical requirements and has the lowest price will be selected for further comparison with Tenders from other Tenderers. Will a more advanced system than specified in the technical requirements be beneficial in the evaluation? No, in the evaluation process, Tenders will only be checked to verify if they fulfil all financial, economical and technical requirements or not. A more advanced solution than required will not give any additional points in the evaluation process. Will different options from the same Tenderer be considered? No, only the Tender that fulfils all financial, economical and technical requirements and has the lowest price will be selected for further comparison with Tenders from other Tenderers. Shall the necessary hardware for the central server application be included in the Tender? No, but any necessary additional hardware or software required to receive and transmit data between the central server application and the measurement stations shall be specified in the Tender. It states in the technical requirement specification that the central server application shall be able to work on a redundant server. How shall this requirement be interpreted?
2 It shall be possible to install the central server application on a redundant server at a later time at the request of the Swedish Radiation Safety Authority. Shall the Tender include installation of the central server application on a redundant server? No, the Tender shall only include installation of the central server application on one server at the Swedish Radiation Safety Authority. Shall the Tender include installation of the client software on workstations at the Swedish Radiation Safety Authority? Yes, the Tender shall include installation of the client software on five workstations placed at the Swedish Radiation Safety Authority. It states in the technical requirement specification that the central server application shall be able to store data in a Microsoft SQL database. Is this correct? The requirement shall be interpreted as the ability to store data in a Microsoft SQL server database. It states in the technical requirement specification that the measurement station shall be able to measure the operating temperature. Does this refer to the outdoor temperature or the temperature inside the measurement station? The measurement station shall be able to measure the temperature inside the measurement station. If a solution with separate units for control, detector and backup battery is offered, the measurement station shall be able to measure the temperature inside the detector unit. It states in the technical requirement specification that the quality information of the measurement station shall include, among other parameters, internal humidity status and internal temperature status. What do the terms internal and status refer to and shall the measurement station be able to measure humidity? The measurement station shall be able to measure and register the temperature and humidity inside the measurement station. If a solution with separate units for control, detector and backup battery is offered, the measurement station shall be able to measure and register the temperature and humidity inside the detector unit. The term status refers to the actual value of the temperature or humidity measurement, not the status of the temperature or humidity sensor.
3 Shall the measurement station be able to measure precipitation type? No. Shall the measurement station be able to measure wind speed and wind direction? No. Shall the Tender include all software upgrades for three years following the delivery or only corrections of identified faults in the software caused by the Tenderer? The Tender shall include all upgrades of the software for three years following the delivery. s and answers published The specified measurement range for the precipitation measurement is down to 10 C. Shall the precipitation sensor be able to correctly measure the amount of precipitation in form of snow? : Yes. Regarding the requirement for Power Supply External Interface; What is the length of the mains power cable to be offered? : The mains power cable shall be at least five (5) meters. The mains power cable shall have type approval H07RN-F, H07BQ-F or better. Regarding the requirement for Power Supply External Interface; What is the required type of mains power connector to be offered? : The mains power connector shall be of CEE form with 3 pins and designed for V and 16A. Regarding the requirement for Power Supply External Interface; What is the required protection class of the mains power connector? : The protection class of the mains power connector shall be IP 44 or better.
4 Regarding the requirement for Set and Modify Parameters Locally; What is the difference between process parameters and configuration parameters? : There is no clear difference between process and configuration parameters. In the invitation for Tender, process parameters are e.g. parameters for the statistical analysis of the data and configuration parameters are e.g. parameters for setting up the detector(s) and sensor(s). The requirement shall be interpreted in such a way that it shall be possible to set and modify relevant parameters for the operation of the measurement station locally using an external PC that has established a local connection to the measurement station. Regarding the requirement for Protection Class; Is IP67 also valid for the precipitation sensor or is IP65 sufficient? : The precipitation sensor shall have a protection class of IP 67 or better. Regarding the requirement for Redundant Server; Looking at the software components at least three (3) main components can be identified in the central system: - FTP server for GPRS / TCP/IP communication - Server application software - SQL database Please specify which of these components should be installed on a redundant hardware? : The requirement shall be interpreted in such a way that it shall be possible to install the central server application on a redundant server at a later time at the request of the Swedish Radiation Safety Authority. The installation of the above mentioned components on a redundant server shall therefore not be included in the Tender. Regarding the requirement for Redundant Server; Please specify the PC hardware system on which it shall be possible to install the software? : The central server application shall be able to run on a redundant server with Intel x86 architecture and Microsoft Windows Server Regarding the requirement for Database; Shall the database also fulfil the redundancy requirement, thus be installed on different (redundant) server with automatic database replication between each other and, if f yes, does the Tenderer has to provide the setup of the database replication or is this provided by SSI IT department? : No, the database shall not fulfil the redundancy requirement. The setup of the database replication shall not be included in the Tender. This is provided by the Swedish Radiation Safety Authority using a separate system not included in the Invitation for Tender.
5 Regarding the requirement Receive and Transmit Data; Is a FTP server available on the SSM hosted website and can this be used for the data transmission if a FTP server is necessary for the data transmission by GPRS? : The Swedish Radiation Safety Authority will provide the necessary hardware to receive and transmit data between the central server application and the measurement stations. Standard communication protocols, such as an FTP server or a Web server will be available. It shall be clearly stated in the Tender if a non-standard communication protocol is needed to receive and transmit data between the central server application and the measurement stations. Is the Tenderer responsible for provision/setup of the public FTP-server or is this provided by SSM? : See previous answer. Is SSI providing the necessary security for the GPRS/internet communication (Firewall ) or is this in the responsibility of the Tenderer? : The Swedish Radiation Safety Authority will provide the necessary security for the GPRS/internet communication. Regarding the requirement Report Generation; Shall the described report function be an automatic process which creates time scheduled reports automatically (i.e. automatic daily report) or is the report to be created automatically upon users request? : The central server application shall be able to create time scheduled reports automatically. Regarding the requirement Alarm Notification; Is it acceptable to use an internet service provider, who provides a conversion from to SMS for the generation of SMS? : Yes. s and answers published Regarding the requirement Endurance Temperature; Shall the monitoring station be able to withstand ambient air temperatures between -50 ºC and +50 ºC without being damaged even in the event of a mains power supply failure in combination with a backup battery failure? : The requirement regarding Endurance Temperature must only be fulfilled given that the measurement station get power from either the external power supply or the backup battery.
6 Is it required to measure the temperature in the housing for the electronics if the detector(s) is placed separate from the housing or is it sufficient to measure the temperature only in the detector unit? : See answer to previous question concerning the temperature measurement published on the website of the Swedish Radiation Safety Authority on the 7 th of July The measurement station shall be able to measure the temperature inside the measurement station. If a solution with separate units for control, detector and backup battery is offered, the measurement station shall be able to measure the temperature inside the detector unit. Regarding the requirement on Receive and Transmit Data and the answer concerning this requirement published on the website of the Swedish Radiation Safety Authority on the 10 th of July 2008; Shall the hardware at the measurement stations necessary to receive and transmit data between the central server application and the measurement stations be included in the Tender? : The hardware at the measurement stations necessary to receive and transmit data between the central server application and the measurement stations shall be included in the Tender. The Swedish Radiation Safety Authority will provide the necessary hardware for the central server application to receive and transmit data between the central server application and the measurement stations. If a technical solution where a certified dose rate detector is placed inside a housing is chosen; Must the dose rate measurement for the housing with the detector inside be certified in itself? All requirements in the technical requirement specification shall be fulfilled regardless of chosen technical solution for the measurement station. Regarding the tender procedure and the related terms of delivery; Has the Swedish Radiation Safety Authority already a fixed or final date for the contract award decision, as the offer should be valid at least 90 days and the date of delivery must be before December 31, The Swedish Radiation Safety Authority will make the contract award decision as soon as possible and not later than the 4th of September The deadline for delivery of the proposal is indicated as "before August 13th"; Please clarify if the proposal package has to be delivered before of August 12th or August 13th. The deadline for delivery of a Tender to the Swedish Radiation Safety Authority is at on the 13 th of August 2008.
Domonial, le Sucre. Easy to Use Intruder Detection Systems
Domonial, le Sucre Easy to Use Intruder Detection Systems Domonial Brief description With over a million installed sites, Domonial is one of the most popular remotely monitored wireless security systems
More informationVesta Visual Verification Alarm System - MJ Series. Keeping Home in Sight on Your Smartphone
Vesta Visual Verification Alarm System - MJ Series Keeping Home in Sight on Your Smartphone A paradigm of simplicity and convenience Climax s MJ control panel series sets up a complete security network
More informationSOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
More informationLEARNING SOLUTIONS website milner.com/learning email training@milner.com phone 800 875 5042
Course 6451B: Planning, Deploying and Managing Microsoft System Center Configuration Manager 2007 Length: 3 Days Published: June 29, 2012 Language(s): English Audience(s): IT Professionals Level: 300 Technology:
More informationEDL-Portal. Energiedienstleistung
Energiedienstleistung EDL-Portal EDL-Portal 2.0 Energiedienstleistung EDL stands for energy services (EnergieDienstLeistung). The EDL internet portal, www.edl.ch, provides a user-friendly platform for
More informationLocation awareness. Home area
1 Location awareness Alarm off Bluetooth, WiFi or GPS can be used to detect when the phone leaves the home area. For Bluetooth and WiFi the home area is defined by the coverage area of the network they
More informationOverview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
More informationAssociate in Science Degree in Computer Network Systems Engineering
Moorpark College Associate in Science Degree in Computer Network Systems Engineering To earn an Associate in Science Degree with a major in Computer Network Systems Engineering, students complete 40.5-45
More informationReducing operating costs of telecom base stations with remote management
Reducing operating costs of telecom base stations with remote management Whitepaper How remote management can be used to cut operating expenses of existing telecom infrastructure. HMS Industrial Networks
More informationAutoLog ControlMan. Remote Monitoring & Controlling Service
AutoLog 1 AutoLog ControlMan Remote Monitoring & Controlling Service Web browser based HMI / SCADA interface Server is hosted by Internet server hosting company Control units communicate wirelessly via
More informationComputer Information Systems
Full Time Job Title: IT Technician Job Number: 2245 Hours/Days: Varies Salary: Approximate Location: Los Angeles, CA Skills Information Technology (IT) Technician will be the primary provider of support
More informationWhite Paper. Wireless FF HSE connection successfully setup at Shell Test Lab. Summary. Overview
White Paper Wireless FF HSE connection successfully setup at Shell Test Lab Overview Summary Shell tested wireless connections at their global test lab. Two different connections were tested: Connections
More informationFIRE ALARM SYSTEM. reliable fire detection and alarm signalling system
FIRE ALARM SYSTEM reliable fire detection and alarm signalling system Satel fire alarm devices allow to implement reliable and modern systems responsible for fire safety. A combination of 20-year experience
More informationTechnical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7
1 de 7 1. Introduction This Technical Note explains how to configure the Modbus Gateway for Vantage Pro2. The Modbus Gateway allows the easy connection of a PLC (Programmable Logic Controller), RTU (Remote
More informationProduct Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors
Product Description You need to protect the equipment in your data center, computer room, or equipment room from the damaging effects of high temperature and high humidity. The best way to protect sensitive
More informationStorage Guardian Remote Backup Restore and Archive Services
Storage Guardian Remote Backup Restore and Archive Services Storage Guardian is the unique alternative to traditional backup methods, replacing conventional tapebased backup systems with a fully automated,
More informationCrow Limited Warranty. Print Version 017
Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose
More informationSensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: +27 11 608 4270 ; www.batessecuredata.co.
Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: +27 11 608 4270 ; www.batessecuredata.co.za 1 Environment Monitoring in computer rooms, data centres and other facilities
More informationSmart. Scalable. Simple.
Thermo Scientific Wireless Monitoring Solution Smart. Scalable. Simple. providing the protection you need with the simplicity you deserve Thermo Scientific Wireless Monitoring Solution Optimized Sample
More informationFirmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
More informationNetwork Setup Instructions
Network Setup Instructions This document provides technical details for setting up the Elite Salon & Spa Management program in a network environment. If you have any questions, please contact our Technical
More informationReliable Security Solutions
Reliable Security Solutions Challenger10 The proven solution for access control, intrusion detection and video integration. An integrated security solution for your most challenging environments The Tecom
More informationTk20 Network Infrastructure
Tk20 Network Infrastructure Tk20 Network Infrastructure Table of Contents Overview... 4 Physical Layout... 4 Air Conditioning:... 4 Backup Power:... 4 Personnel Security:... 4 Fire Prevention and Suppression:...
More informationComputer Network & ICT Support Technician
Computer Network & ICT Support Technician The general competencies and skills enlisted in this document encompass the principle background needed for a Computer Network & ICT Support Technician to carry
More informationAdministering a Microsoft SQL Server 2000 Database
Aug/12/2002 Page 1 of 5 Administering a Microsoft SQL Server 2000 Database Catalog No: RS-MOC2072 MOC Course Number: 2072 5 days Tuition: $2,070 Introduction This course provides students with the knowledge
More informationImmotec Systems, Inc. SQL Server 2005 Installation Document
SQL Server Installation Guide 1. From the Visor 360 installation CD\USB Key, open the Access folder and install the Access Database Engine. 2. Open Visor 360 V2.0 folder and double click on Setup. Visor
More informationManaging and Maintaining Windows Server 2008 Servers
Managing and Maintaining Windows Server 2008 Servers Course Number: 6430A Length: 5 Day(s) Certification Exam There are no exams associated with this course. Course Overview This five day instructor led
More informationApplication Note: Upgrading Interceptor software with FTP server on local PC
Application Note: Upgrading Interceptor software with FTP server on local PC The Interceptor has the capability to accept software upgrades, which are available from NIS Tech Support (support@networkintegritysystems.com).
More informationSemaphore T BOX Applications in Data Center Facilities
Semaphore T BOX Applications in Data Center Facilities Introduction Data centers must reliably provide 24/7/365 operation. For automation and monitoring of the facility, use of a rugged, reliable RTU is
More informationGE Security. FHSD Monitor / Web Server user manual
GE Security FHSD Monitor / Web Server user manual version 1-0 / november 2004 http://www.geindustrial.com/ge-interlogix/emea 2004 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the
More informationUSB Edition TM-STD30 User Guide
USB Edition TM-STD30 User Guide 1 Rev 4.0.8 http://www.temperaturealert.com/ 2012 Temperature@lert User Guide Thank you for choosing Temperature@lert. The USB Edition monitors the ambient temperature and
More informationContinuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057-03/G Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total EMF values Electric field monitoring
More informationSMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
More informationTraining Program: Network Admin. Program Structure: Hardware and Appliances. Networking
Training Program: Network Admin Duration: 4 Months Field Work: 30 Days Program Fees: Rs. 44000/- Training Fees: Rs. 7500 /- Program Structure: Hardware and Appliances Introduction to Computers Types of
More informationUser s Manual Network Management Card
User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction
More informationCourse 2788A: Designing High Availability Database Solutions Using Microsoft SQL Server 2005
Course Syllabus Course 2788A: Designing High Availability Database Solutions Using Microsoft SQL Server 2005 About this Course Elements of this syllabus are subject to change. This three-day instructor-led
More informationTECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM
HELLENIC ELECTRICITY DISTRIBUTION NETWORK OPERATOR S.A. NOTICE OF CALL FOR TENDERS No ND-xxx PROJECT: Pilot Telemetering and Management System for the Electric Power Supply Demand by Residential and Small
More informationConfiguring and Deploying a Private Cloud with System Center 2012 MOC 10751
Configuring and Deploying a Private Cloud with System Center 2012 MOC 10751 Course Outline Module 1: Planning for the Private Cloud This module describes the core components of a private cloud and the
More informationIDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited
(Rev. 1.0) China Aerospace Telecommunications Limited Contents 1. Introduction......3 2. Specifications...4 2.1 External Interface... 4 2.2 Status Indicator...... 5 2.3 Technical Parameters... 6 3. Device
More informationVST-1815Z IP V-Alarm System VST-1852Z IP/GPRS V-Alarm System
VST-1815Z IP V-Alarm System VST-1852Z IP/GPRS V-Alarm System VST-1815Z/ VST-1852Z is an IP based home control system that offers Video Verification & Remote Look in. VST-1815Z/ VST-1852Z can support PIR
More informationUSB Ethernet Connectivity Kit
Shipping & Mailing Postage management DM00, 0, 800, 800i, 900, 1000, 1100 Systems USB Ethernet Connectivity Kit Technical Support Configuration Guide Table of contents Confidentiality Limitations of this
More informationAdministering a Microsoft SQL Server 2000 Database
Administering a Microsoft SQL Server 2000 Database Course 2072 - Five days - Instructor-led - Hands-On Introduction This course provides students with the knowledge and skills required to install, configure,
More informationHome Passport Gateway Series Simplify your Life with Smart Solutions
Home Passport Gateway Series Simplify your Life with Smart Solutions HPGW Series - Home Passport Gateway Series HPGW Series is Home Passport Gateway, representing a breakthrough product in the intrusion
More informationXactimate v.27 Network Installation
Xactimate v.27 Network Installation Requirements Like all networked software applications, Xactimate Version 27 must be installed on a workstation connected to a network that has been properly set up and
More informationWhite Paper ClearSCADA Architecture
White Paper ClearSCADA Architecture ClearSCADA has 3 major components or software applications; the ClearSCADA server, a windows client known as, and a web client known as Webx. The software is designed
More informationSCADA and Monitoring for Solar Energy Plant
SCADA and Monitoring for Solar Energy Plant Segment: Industry Country: Thailand Author: Ranon Satitpanyapan Products: NI LabVIEW with LabVIEW Real-Time Module crio Real-Time controller 8 slot with 16 current
More informationKokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS
Kokii BatteryDAQ BMS Battery Analyzer Battery DAS Updated: October 2008 Caution: High Voltage Exists on Battery Power and Sampling Connectors! Please refer to device installation and operation manual for
More informationRadiological Assessment Display and Control System
Features Fast, real-time data acquisition and control Highly reliable communication with remote terminal units Collecting, converting, integrating and analyzing data from all monitors Detecting, annunciating
More information70-646 R3: Windows Server 2008 Administration. Course Overview. Course Outline. Course Length: 4 Day
70-646 R3: Windows Server 2008 Administration Course Length: 4 Day Course Overview This course will prepare the student for Exam 70-646: Pro: Windows Server 2008, Server Administrator. Topics covered include
More informationCellular Edition TM- CELL400 User Guide. 1 TM- CELL400 Rev 1.2 http://www.temperaturealert.com/ 2012 Temperature@lert
Cellular Edition TM- CELL400 User Guide 1 TM- CELL400 Rev 1.2 http://www.temperaturealert.com/ 2012 Temperature@lert User Guide Thank you for choosing Temperature@lert to protect your highly valuable belongings
More informationUltra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
More informationUltimate Server Client Software
Ultimate Server Client Software GPRS NET Data Logger Ul mate Server is dedicatedly developed for high volume data applica on. 1. Receive data from Data Loggers in UDP or TCP via GPRS, Ethernet and SMS
More informationsecurityprobe 5E Standard
securityprobe 5E Standard securityprobe 5E Standard Monitor the physical environment and receive alerts of any disturbances, such as unauthorized intruders, security breaches, high temperatures, smoke,
More informationF2F Storage Facility Monitoring System and Software Integration
F2F Storage Facility Monitoring System and Software Integration Igor Bondar, Mikhail Osipov, Egor Terushev, Dmitry Pazhin, Boris Barkanov, Anatoly Amelichev All-Russian Scientific Research Institute of
More informationCourse Syllabus. Course 6451A: Planning, Deploying and Managing Microsoft Systems Center Configuration Manager 2007. Key Data.
Key Data Product #: 3384 Course #: 6451A Number of Days: 5 Format: Instructor-Led Certification Exams: This course helps you prepare for the following Microsoft Certified Professional exams: 70-401 TS:
More informationHow To Install And Set Up The Database For Quicdoc And Office Therapy (The Applications)
Server Database Installer for QuicDoc and Office Therapy Installation Guide What you need to know before you start This Guide was written to assist you in installing and setting up the Database system
More informationInstallation and Connection Guide to the simulation environment GLOBAL VISION
Installation and Connection Guide to the simulation environment GLOBAL VISION Hardware and Software Requirements The following hardware specification is recommended for client machines: 2 GHz Pentium class
More informationOSM 2007 MONITORING SOFTWARE
OSM 2007 MONITORING SOFTWARE Contents Preparation...3 Software Installation...4 Configuring OSM...6 Connecting a Device...16 Connecting to Station Monitoring Software...19 Troubleshooting...23 Installing
More informationAcquiring i data from the field level l to a SQL database
M2M SQL Connector - a Turnkey Solution Dt Data Acquisition Data Logging Transmission SQL Database Acquiring i data from the field level l to a SQL database M2M Data Management 5 Steps: 1. Data Acquisition
More informationSecurity Alarm Systems
Security Alarm Systems Monitored alarm systems offer clients peace of mind as they activate on intrusion or tampering at the property and ensure any security alarm will have an appropriate response. However,
More informationBidirectional wireless communication using EmbedRF
Bidirectional wireless communication using EmbedRF 1. Tools you will need for this application note... 2 2. Introduction... 3 3. Connect EmbedRF Board to USB Interface Board... 3 4. Install and Run EmbedRF
More informationStruxureWare TM Data Center Expert
StruxureWare TM Data Center Expert Infrastructure management from rack to row to room to building Deploy in minutes, manage from anywhere, analyze instantly, integrate with other management systems. End
More informationCommon Questions & Answers
Common Questions & Answers Summary of Advantages Honeywell has proven manufacturing and design capability, distribution expertise and the field training/ support necessary for a successful partnership
More informationPrint Audit 6 - SQL Server 2005 Express Edition
Print Audit 6 - SQL Server 2005 Express Edition Summary This is a step-by-step guide to install SQL Server 2005 Express Edition to use as a database for Print Audit 6. Pre-Requisites There are a few pre-requisites
More informationNetwork Client. Troubleshooting Guide FREQUENTLY ASKED QUESTIONS
Network Client Troubleshooting Guide 1 Network Client Troubleshooting Guide The first section of this guide answers some frequently asked questions (FAQs) about the operation of Intellex and the Network
More informationIPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network
IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This
More informationMCAPS 3000 DISASTER RECOVERY GUIDE
MCAPS 3000 DISASTER RECOVERY GUIDE Manual Part Number 99875294-1 FEBRUARY 2004 REGISTERED TO ISO 9001:2000 1710 Apollo Court Seal Beach, CA 90740 Phone: (562) 546-6400 FAX: (562) 546-6301 Technical Support:
More informationHow To Set Up Safetica Insight 9 (Safetica) For A Safetrica Management Service (Sms) For An Ipad Or Ipad (Smb) (Sbc) (For A Safetaica) (
SAFETICA INSIGHT INSTALLATION MANUAL SAFETICA INSIGHT INSTALLATION MANUAL for Safetica Insight version 6.1.2 Author: Safetica Technologies s.r.o. Safetica Insight was developed by Safetica Technologies
More informationVirtual Server in SP883
Virtual Server in SP883 1 Introduction: 1.1 Micronet SP883 is a hard QoS broadband router, means its guaranteed service can provide absolute reservation of resource (bandwidth) for specific traffic;not
More information5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
More informationRAS Associates, Inc. Systems Development Proposal. Scott Klarman. March 15, 2009
Systems Development Proposal Scott Klarman March 15, 2009 Systems Development Proposal Page 2 Planning Objective: RAS Associates will be working to acquire a second location in Detroit to add to their
More informationHMS Industrial Networks. Putting industrial applications on the cloud
HMS Industrial Networks Putting industrial applications on the cloud Whitepaper Best practices for managing and controlling industrial equipment remotely. HMS Industrial Networks Inc 35 E Wacker Drive,
More informationEnvironmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%
ARIOM World wide sales & support network Physical Size W x H x D: 485x133x415 (mm) Rack Standard:19, 3U Weight: 10 kg, (21,5 lbs) Power: Input (main) 100-240 VAC, 50-60 Hz Backup: 24 VDC Power Consumtion:
More informationManaging Mobile Devices Over Cellular Data Networks
Managing Mobile Devices Over Cellular Data Networks Best Practices Document Best Practices Document www.soti.net We Manage Mobility TABLE OF CONTENTS UNIQUE CHALLENGES OF MANAGING DEVICES OVER CELLULAR
More information- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).
Page 1 of 30 Page 2 of 30 1. Basic terminology - Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF). - Remote Element:
More informationCONSTRUCTION / SERVICE BILLING SYSTEM SPECIFICATIONS
CONSTRUCTION / SERVICE BILLING SYSTEM SPECIFICATIONS Jonas Software, March 2013 Contents Introduction... 3 Hardware Specifications... 4 Recommended Server Hardware Specifications... 4 Recommended Workstation
More informationPowerCommand iwatch 100 Remote Network Monitoring
PowerCommand iwatch 100 Remote Network Monitoring Description The PowerCommand iwatch provides a convenient means for remotely monitoring generator sets and transfer switches. The Microsoft Internet Explorer
More informationII. Implementation and Service Information
II. Implementation and Service Information A. Responsibilities The procedure for setup with KeyBank s standard transmission services consists of three phases: 1) communications testing, 2) applications
More informationWorld Food Programme. Grasp Manual. An Overview
World Food Programme Grasp Manual An Overview irene.ferrari 10/24/2013 Contents Introduction:... 2 GRASP Installation: Hardware / Software specifications for GRASP data collection setup and installation
More informationData Logger & Net Client Software (Windows, ipad, Android) Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment!
Data Logger & Net Client Software (Windows, ipad, Android) builds an Intelligent HMI system Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment! Running a HMI system with your
More informationEthernet Adapter Owner's Manual
Corinex Intelligent PowerNet Corinex Intelligent PowerNet Ethernet Adapter Owner's Manual This Owner s Manual, as well as the software described in it, is furnished under license and may be used or copied
More informationPatriot Hardware and Systems Software Requirements
Patriot Hardware and Systems Software Requirements Patriot is designed and written for Microsoft Windows. As a result, it is a stable and consistent Windows application. Patriot is suitable for deployment
More informationhttp://docs.trendmicro.com
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the product, please review the readme files,
More informationPCMCIA Wireless LAN Card User s Manual
PCMCIA Wireless LAN Card User s Manual Rev 1.0 Regulatory compliance FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
More informationSafexpert Installation instructions MS SQL Server 2008 R2
Safexpert Installation instructions MS SQL Server 2008 R2 Version: 22.06.2012 IBF-Automatisierungs-und Sicherheitstechnik GmbH A-6682 Vils Bahnhofstraße 8 Tel.: +43 (0) 5677 5353 0 E-mail: office@ibf.at
More informationQuestions and Answers, PA0950243, Web Hosting and Data Analysis
Questions and Answers, PA0950243, Web Hosting and Data Analysis Question #1: 5.1.4 Key areas of technical expertise: 1) Microsoft Structured Query Language (SQL) Server 2003 Management & Support: There
More informationRanch Networks for Hosted Data Centers
Ranch Networks for Hosted Data Centers Internet Zone RN20 Server Farm DNS Zone DNS Server Farm FTP Zone FTP Server Farm Customer 1 Customer 2 L2 Switch Customer 3 Customer 4 Customer 5 Customer 6 Ranch
More informationYour Technical Point of Contact s Role
3 Your Technical Point of Contact s Role The TPOC will be the overall central point of contact for all issues related to AT&T Managed Internet Service with VoIP (MIS with VoIP) at your company. At a minimum,
More informationRFQ 12-21 IT Services. Questions and Answers
RFQ 12-21 IT Services Questions and Answers Question # 1: Just to clarify and I am more than certain that this is just a typo, but the due date for the submission of the IT Services RFP is January 7, 2013,
More informationMCSE: Private Cloud Training Course (System Center 2012)
MCSE: Private Cloud Training Course (System Center 2012) Microsoft Course 10751 (Exam 70-247) Prerequisites MCSA: Windows Server 2012 Microsoft Course 10751 Exam 70-247 At Course Completion Prerequisites
More informationSNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
More informationMicrosoft Technologies
NETWORK ENGINEERING TRACK Microsoft Technologies QUARTER 1 DESKTOP APPLICATIONS - ESSENTIALS Module 1 - Office Applications This subject enables users to acquire the necessary knowledge and skills to use
More informationTechnical Overview CM-2 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk
Technical Overview CM-2 Climate Monitor Get yours direct at: 01491 410913 www.theclimate.co.uk The importance of effectively monitoring IT environments has never been greater. There are a multitude of
More informationPremium Server Client Software
Premium Server Client Software Server / Client SMSPro & GSMS TH series Get the tools on hand Premium Server is designed to cover most of the applications in the market. It gives a hassle free management
More informationVS-100. PoE. H.264 PoE Video Server. H.264 Compression H.264 DI/DO. Compression Rate Comparison MJPEG MPEG4 H.264.
H.264 Video Server T he AirLive is a one channel video server for easily upgrade your old CCTV camera to a network-enabled IP camera and hence convert your local surveillance system into a global one.
More informationJOB OPENING. Please see attached Job Description: Last day to apply: February 27, 2013
JOB OPENING Position: Reports To: Manager of Technology Operations Location: Aledo Position Requirements: Associate s degree in computer science or electronics and/or certification such as MCSE, CNE, A+,
More informationPLC GPRS NET Data Logger
GPRS NET Data Logger Mul Channels GPRS Wireless & Ethernet Network Transmission & Data Logging Upload Data via GPRS, SMS & Ethernet on schedule or alarm triggered Programmable data logging and upload interval
More informationHow To Use Netbiter
- Remote management of industrial applications Save time, save energy, save resources! Your challenges Minimize scheduled and emergency on-site service Optimize service operations through efficient machine/device
More informationTechnical Overview CM-16 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk
Technical Overview CM-16 Climate Monitor Get yours direct at: 01491 410913 www.theclimate.co.uk Need a lot of remote sensors in a rack mount? The CM-16 has web access, graphing, and alarm alerts sent by
More informationProactively Managing Your NT Infrastructure with Event Log Monitor. TNT Software
Challenges of Administering Windows NT/2000 Single system providing critical services Internet server in DMZ (e.g., FTP, HTTP, SMTP) Corporate File & Print, Email or Database Server Other critical island
More information