Nu-Heat. user guide. hitachi yutaki air source heat pump. design innovation expertise service

Size: px
Start display at page:

Download "Nu-Heat. user guide. hitachi yutaki air source heat pump. design innovation expertise service"

Transcription

1 Every Nu-Heat system is a custom design. Please record your unique System Reference number for future reference: System Ref: Nu-Heat U N D E R F L O O R & R E N E W A B L E S user guide hitachi yutaki air source heat pump design innovation expertise service

2 2

3 user guide for the hitachi yutaki air source heat pump This guide is aimed at providing a basic understanding of the heat pump system installed within your property. You will find references here to other leaflets, such as the manufacturer s user guide for the Hitachi wireless room unit and also the Nu-Heat Underfloor Heating User Guide. Contents Page 4 The Installation 4 System component identification 5 The Heat Pump and System 5 How do heat pumps work? 5 Running patterns and flow temperatures 6 Buffer tank 6 Average house temperature 6 Weather compensation 6 Domestic hot water 6 Coefficient of Performance or CoP 6 Bivalent point 7 The Controls 7 Room thermostats 7 Wireless room unit 7 Increasing the room temperature in a particular room 7 Increasing the room temperatures generally 8 Hot water programmers 8 Domestic hot water programmer 8 Legionella purge programmer 8 Secondary hot water loop programmer (if installed) 8 Separate towel rail circuit programmer (if installed) 9 Running the System Economically 9 Heat pump set-up 9 First year of use 9 Choice of heating mode 9 Hot water temperature 9 Hot water reheat 9 Electrical tariff 9 Extreme weather 10 Maintenance 10 Heat pump 10 Controller 11 Heating system 11 Radiator system 11 Domestic hot water cylinder 12 Maintenance log 14 Glossary of terms 3

4 HITACHI i SEL HITACHI + - SET The Installation Comprehensive information about the heat pump installation is in the MCS Handover Pack you should already have received from your system installer. System component indentification Example layout (actual layout may differ) Legionella purge programmer Towel rail programmer Towel rail circulation pump 8 Towel rail zone valve Towel rail circuit Pipe stat 11 UFH circuit Radiator circulation pump Radiator circuit Nu-Heat Air source heat pump, Yutaki 2. Domestic hot water cylinder 3. Heat pump controller 4. Room unit (heating programmer) 5. Domestic hot water timer 6. Domestic hot water loop (if installed) 7. Towel rail circuit (if installed) 8. Heating system expansion vessel, pressure gauge and filling loop 9. Heating system filter and isolation valves 10. Heating system air separator (self venting) 11. Backup immersion heater and thermostat 12. Domestic hot water immersion heater and thermostat 13. Domestic hot water cylinder overheat cut-out 14. Buffer tank 4

5 The Heat Pump and System The air source heat pump installed in your property has been carefully chosen by Nu-heat to provide the highest level of efficiency. If the system is operated as recommended in this user guide, and in the user guide supplied with the heat pump controller, then it should operate efficiently and reliably for many years to come. Keep the heat pump clear of vegetation and debris such as sticks or fallen leaves. Make sure air circulation is not obstructed by garden furniture or bicycles etc being leant against it. The unit contains powerful fans which must not be obstructed. During the winter ice will build up on the heat exchanger at the rear of the unit (the evaporator ). The heat pump has a built in feature to allow it to feed heat through to periodically melt the ice. This will result in water and steam issuing from the unit and is part of the normal operation of the heat pump. Keep drain ways clear around the unit so that this water can run away. Read the rest of this guide to find out how to get the best from your heat pump. How do heat pumps work? Air source heat pumps work by compressing low grade energy from the air outside into high grade energy for heating and hot water production. Hitachi heat pumps use the vapour-compression refrigeration cycle to transfer energy from the outdoor air to the water in the heating system. Even at temperatures as low as -20 C it can supply significantly more energy than it uses. HITACHI warm air cold air warm water Heat pump systems and boiler systems are designed to operate in very different ways. It is important to understand these differences in order to ensure that the heat pump system is set up and operated correctly. Running patterns and flow temperatures A traditional boiler system is usually oversized for the property and is designed to work at a high flow temperature. The boiler will generally run for limited periods of time even in cold weather. In contrast the heat pump will have been sized to match much more closely the steady state heat load for the property, and is therefore able to run all day economically in cold weather. This is done to utilise the lower water flow temperature that the heat pump produces. If it were required to produce higher temperatures then the efficiency would be compromised efficiency goes down as the water flow temperature goes up. Radiators supplied from a heat pump will be warm rather than hot to the touch but, being larger than usual and warm for a longer period, will still maintain the house at a comfortable temperature. Underfloor heating, which by its nature requires lower water temperatures than radiators, is often the preferred choice. 5

6 Buffer tank The use of a buffer tank increases the effective volume of the heating system and allows the heat pump to build up a reserve of heat energy in the water stored in the buffer tank. This prevents the heat pump from short-cycling and also stores heat for the defrost function. Average house temperature A Nu-Heat heating system is designed to maintain the property at 21 C for living areas, and 18 C for bedrooms. With underfloor heating the temperature can afford to actually be a degree or so lower without sacrificing comfort. Whether the system comprises underfloor heating or radiators it must be borne in mind that increasing the house temperature will increase the building heat loss, and hence the running cost. It is recommended that the target room temperature is set at no more than 21 C in living rooms and 18 C in bedrooms. Weather compensation During the milder parts of the heating season less heat is required to maintain comfort levels. The heat pump measures the outdoor temperature and adjusts the temperature of water being fed to the heating system - the warmer it is outside the lower the flow temperature and so the higher the efficiency of the heat pump. This method of operation is called Weather compensation and is critical to enabling the heat pump to operate efficiently by allowing it to always work at the lowest possible flow temperature. In contrast, a boiler system usually operates at a fixed flow temperature of anything up to 86 C, irrespective of how much heat is required. Domestic hot water The efficiency of the heat pump is less when it is used for generating domestic hot water, because the heat pump is normally required to supply the cylinder with water at a higher temperature than is used for space heating. To maximise the efficiency, domestic hot water is stored at a lower temperature than in a conventional boiler system. For this reason the cylinder must be larger in order to provide sufficient capacity for normal baths and showers. Coefficient of Performance or CoP The efficiency of the heat pump is also referred to as its CoP, and is the result of the power output divided by the power input. For an air source heat pump CoP is generally in the range 2.5 to 4 but it varies all the time, as the outside air temperature varies. Bivalent point As the outside air temperature drops, there eventually comes a point where the heat pump on its own cannot maintain your comfort levels within the property. This critical outside temperature is called the Bivalent point. A typical bivalent point might be between -3 C and 0 C but the actual bivalent point for your system will depend on the characteristics of your house and of the heat pump. Below the bivalent point there is likely to be a need for backup heating. The backup heating element will then be required to supplement the heat pump s output, but it will be less efficient and noticeably more expensive to run than the heat pump itself. It is important to note that during colder than average winters this backup heating will be called into action more frequently. Conversely in milder winters the backup heat source may not be required at all 6

7 The Controls Room thermostats Guidance on how to use our standard range of room thermostats is contained in the Nu-Heat Underfloor Heating User Guide. For a heat pump system, room thermostats do not control the heat pump itself, just the flow of water from the buffer tank to an individual room zone. The heat pump will instead be controlled by the dedicated wireless room unit. Wireless room unit The main user control is the wireless room unit. This unit allows you to adjust for your preferred comfort level for the heating system. It works as the main heating programmer, measuring the room temperature to determine whether the heat pump shall run. The wireless room unit should be located in a room without any other form of control (i.e. there must be no other room thermostat), usually a living area or hallway. Avoid placing the unit in sunlight, in a draught or above a local heat source such as a towel rail, radiator or cooker. (The A3 Manifold & Zone Information drawings, to be found in the MCS Handover Pack, show where the wireless room unit can best be located.) Operating modes There are three different operating modes: auto mode: In auto mode the heating programme runs as set. The system will be more efficient and provide greater comfort in manual mode. manual man mode: In man mode a constant temperature is maintained. This should be 21 C. off mode: In off mode the system will only maintain a frost protection temperature of 5 C. off mode can be used during the summer when no heating is required. Increasing or decreasing the room temperature in a particular room Rooms with a thermostat: Adjust the room thermostat to your preferred temperature but you should normally avoid settings above 21 C. If the room is not warming then an increase of flow rate may be required. Rooms without a thermostat: If individual rooms are not warm enough then firstly the flow rate should be adjusted (see Underfloor Heating User Guide Heat Pump Systems, or the radiator manufacturer s instructions). If adjusting the flow rate is not enough, or if there are multiple rooms (or zones) which aren t up to temperature, then the wireless room unit can be adjusted to increase the flow water temperature generally. Decreasing temperature is achieved by the reverse of the above. Increasing or decreasing room temperatures generally The general room temperature can be increased or decreased using the temperature adjustment buttons which can be seen when the flap on the wireless room unit is closed. The temperature can be adjusted at any time using these buttons, however if the room unit is in the Auto operating mode then the temperature will revert back to the preset temperature at the next time period. If this causes an issue then the preset time and temperature programs will need to be altered as detailed in the Hitachi Room Unit User Guide. 7

8 Hot Water Programmers Domestic hot water programmer A Danfoss TS715 programmer is supplied to control when the heat pump heats the Domestic Hot Water (DHW) cylinder. Full details on how to operate the programmer are provided in the Nu-Heat Underfloor Heating User Guide supplied with the system. When setting the programmer ensure that the time settings chosen allow for the heat pump s longer cylinder re-heat time compared to a boiler system. This could be anywhere between 2 and 4 hours to reheat from cold, depending on heat pump size and outside air temperature. TS715 Hot water programmer The Aquastar2 hot water circulating loop Legionella purge programmer A 13amp programmer is provided to operate the DHW cylinder immersion heater. The main function of this is to raise the cylinder temperature to 60 C for an hour once a week, to purge the cylinder of Legionella and other bacterial growth. This programmer normally runs in automatic timed mode and the commissioning engineer will have been advised to set it to run once a week on Monday morning between 1am and 4am. This should not normally require to be altered. The button can be used to override the programming if the immersion is on then it would be switched off and vice versa. The timer will revert to the programme at the next timing stage. Please see the manufacturer s instructions for more detail. C Secondary hot water loop programmer (if installed) The hot water secondary return should be set to operate for the minimum amount of time required. Ideally it should operate for a maximum of 2 hours in the morning and 3 hours in the evening. Separate towel rail circuit programmer (if installed) The towel rail programmer should be set to operate for the minimum amount of time required. Ideally it should operate for a maximum of 2 hours in the morning and 3 hours in the evening, in periods when the hot water cylinder is up to working temperature. Towel rail 8

9 Running the system economically The heat pump system has been carefully designed to operate efficiently down to below-average weather conditions, however a few things should be taken into account to get the best from it. Heat pump set-up The heat pump has been set up by the commissioning engineer. Its settings should not be changed without full working knowledge of the system and of the parameters calculated during the design process. If there are any doubts about the way a heat pump is set up, Nu-Heat technical support are able to assist customers in checking system parameters. First year of use During the first year after a house has been built the energy required to heat the house can be up to 30% higher than normal due to the need to dry out the fabric of the building and because the damp walls and floors are more thermally conductive. If the initial switch-on of the system occurs in the winter then this can cause issues with poor heating performance as the heat pump is trying not only to heat the house and counter normal heat loss, but also to dry the building out. This can result in a higher than expected amount of supplementary energy being consumed (e.g. direct electric immersion heater). Choice of heating mode In summer the wireless room unit should be set to off mode to reduce standby energy consumption. At other times use auto mode or manual mode and avoid calling on the supplementary heating element unless this is essential. Hot water temperature The hot water temperature must be set so that it is within reach of the compressor without the need for additional heat. A setting of 48 C is normally adequate and is within the capability of all Hitachi heat pump compressors, (the single fan unit is capable of higher temperatures, up to 53 C is sensible). The cylinder immersion heater is normally only required during the periodic Legionella purge cycle. Ensure that the hot water and Legionella purge timeclocks have been correctly identified and set. Hot water reheat Air source heat pumps are most efficient during the warmer daylight hours. With an air source heat pump it is therefore sensible to time the domestic hot water reheat period(s) to occur during the day, but preferably at times when space heating is not a priority. If you have prolonged hot water demand you can alternatively set the hot water timeclock to an extended on period to ensure immediate reheat of hot water on demand. Electricity tariff Studies conducted by Nu-Heat suggest that there is little or no benefit from using an Economy 7 tariff with an air source heat pump, as the majority of consumption occurs outside the low-rate period. However, you will need to consider your other energy usage before choosing the best tariff for your requirements. Whether you choose an Economy 7 or Standard tariff, you should always look around for the best deal in your area as tariffs can vary considerably between different suppliers. Extreme weather In 2009/2010/2011 the United Kingdom experienced two unusually cold winters. Temperatures of 10 degrees below zero, or lower, were common during several months. In these conditions the output of any air source heat pump is significantly reduced, while the heat loss of the building is greatly increased. Any heating system must use fuel more heavily during such a period, and a heat pump is no exception to this rule. Below the bivalent point however, a heat pump system will start to draw on its supplementary heating element, the efficiency of which is far below that of the heat pump itself. If you have a cheaper form of supplementary heating than direct electric, such as a wood burning stove, then this is the time to use it. 9

10 Buffer tank floor or wall mounted dependant on installation space. Maintenance Whilst heat pumps are, in principle, maintenance free it is recommended that your heating system should be checked annually to ensure that it runs as efficiently as possible. This is also a condition of the heat pump and hot water cylinder warranties. This maintenance must be carried out by a competent person, and with reference to the manufacturer s instructions. The heating system filling loop is used to re-fill the system should the pressure on the gauge fall below 1 bar. When the system is initially setup there will probably be a small amount of air in the system, this should be released through the automatic air vents. The lost air will cause a pressure drop in the system, easily corrected by the addition of water via the filling loop. However, a frequent need to pressurise the system may indicate a leak, you should contact your installer to have this investigated. There is a filter (see p.4 item 9) installed on the return pipe back to the heat pump to ensure that any debris in the system does not block the heat exchanger inside the heat pump. This filter should be cleaned periodically to maintain the required water flow rate. The backup immersion heater thermostat in the buffer tank should be set to 60 C. The immersion heater thermostat in the cylinder should be set to 65 C. It is used weekly to purge the cylinder of any bacterial growth (Legionella, for example). This immersion heater can also be used to produce extra hot water, however such use is bound to increase running costs. The cylinder overheat cut-out is a requirement of Building Regulation G3. In the unlikely event that the cylinder temperature exceeds 80 C the switch will cut out, and shut the valve between the heat pump and cylinder. To reset, the black cap should be unscrewed and the reset button depressed. If this is recurring problem then you should contact your installer. Heat Pump Hitachi Yutaki Yutaki (outdoor unit) Check condition of casing Check electrical supply connections Check all visible pipe joints for leakage Check that the inlet and outlet grilles are free from debris (leaves, snow, etc.) Warning: beware of the rotating fan isolate unit if necessary Check that the heat pump base is free draining of condensate Verify correct refrigerant charge by indirect measurement (registered Level A MCS installers only) Controller Check the alarm log for any faults Check electrical control functions (relay test) 10

11 Heating system Please refer to the Underfloor Heating User Guide for details of servicing the Underfloor heating. Clean strainers on heating circuits, ensure system is re-pressurised and introduced air is flushed from system Check the system for any visible signs of leakage Radiator system Check inhibitor levels, and top up if necessary Check the heating system pressure (this should be around 1 bar for a 2-storey building, or more for a taller building) Domestic Hot Water Cylinder Please check the manufacturers cylinder manual for any service record that may be a condition of warranty. Check correct operation of inlet group safety valve Check correct operation of temperature and pressure relief valve Check that all discharge pipes are free from obstruction Check the gas pressure in the potable water expansion vessel Check cylinder sacrificial anode indicator (where applicable) Check the settings and operation of the cylinder hygiene purge The Nu-Heat EnergyMaster2 cylinder 11

12 Maintenance Log Date Engineer s name Company Telephone no. Comments Signature 12

13 Maintenance Log Date Engineer s name Company Telephone no. Comments Signature 13

14 Glossary of Terms Steady state heat loss: Nu-Heat designs heating systems to an indoor temperature of 20 C (18 C for bedrooms) and an outdoor temperature of -3 C. The steady state condition is when the amount of heat being input by the heating system exactly balances the amount of heat being lost from the building, and is assessed at the design temperatures. In order to raise the room temperature it is necessary to input more heat than is being lost. Coefficient of Performance (CoP): Coefficient of Performance is a measure of efficiency for heat pumps. A CoP of 4 means an efficiency of 400%, so for every unit of energy that you put in (electrical energy into the compressor) you get four units of heat out (i.e. three free from the air). The efficiency of a heat pump will vary with the temperature of the source (outside air) and the temperature of the heating water being generated. As the outdoor air temperature increases, so does the efficiency of the heat pump as the compressor has to work less hard to achieve a given output temperature. As the temperature of the heating water rises, the compressor has to achieve a higher gas pressure, using more energy, and the efficiency of the heat pump falls. The actual efficiency is calculated by dividing the power output by the power input. For example, a heat pump delivering 10kW may have a power input of 2.5kW. Hence the CoP is 10/2.5 = 4 (or 400% efficient). The quoted value of an air source heat pump s CoP is often calculated with a source temperature of 7 C and an output water temperature of 35 C. A more useful figure is a seasonally adjusted CoP (Seasonal Performance Factor, SPF) which takes into account average weather conditions over a year in a broad geographical location, and a model of the specific load in question. It also takes into account the amount of energy required from additional heat sources, pumps, valves and other energy consuming devices. Whilst this can only ever be a best guess as there is no such thing as an average year, it does give a better indication of reality than published benchmark figures. Heat pumps are least efficient when producing domestic hot water. In winter, CoP for hot water production can be as low as 2. This is still much better than using a direct immersion heater, whose CoP would be 1 only. Weather compensation: Weather Compensation is where the heating water temperature from the heat pump is changed in accordance with the outdoor temperature. When it is warm outside, not very much heat is being lost from the building and so the heating water can be quite cool and still maintain a comfortable temperature inside. As it gets colder outside, more heat is lost from the building and the water in the heating system needs to be warmer in order to maintain comfort levels inside. The line as shown on the graph above defines the relationship between these two temperatures is called the heating curve. This curve can be selected on the heat pump controller, normally as a number and the shape of the curve can be altered in order to optimise comfort and efficiency of the system throughout the year. 14 Heating water temperature ( C) Outside temperature ( C)

15 Glossary of Terms continued Bivalent point: The bivalent point is defined by a temperature at which the output of the heat pump cannot be increased and is exactly equal to the heat loss of the building. The idea being that at temperatures below the bivalent point the secondary heat source (e.g. direct electric heating) is allowed to switch on. Correctly identifying this temperature will optimise the running of the system to minimise energy costs. Four things are important here: 1) The calculated heat loss of a building at a nominal minimum temperature (say -3 C) 2) The output power of the heat pump 3) The average amount of energy required to run the heat pump 4) The proportion of the year when the temperature falls below the nominal minimum These factors are all taken into account in order to best predict which size of heat pump is suitable for a property. The graph shown below indicates the salient factors of the final design. Building heat loss at -3 degrees outside temperature e.g. 12kW Heat pump output at 15 degrees outside temperature (assume 20 degree flow temperature) e.g. 14kW Heat pump output at -3 degrees outside temperature (assume 45 degree flow temperature) e.g. 8.2kW 0kW Bi-valent point at which additional heat source is required to be enabled e.g. outside temperature of + 1 degree C Heat loss at 15 degrees outside temperature The outside temperature drops in winter and so does the output power of the heat pump. However the energy required to heat the building increases and at a given temperature the two values will be coincident. This temperature is called the bivalent point. Below this point, the heat pump cannot deliver enough power to heat the building to the designed temperature, at which time the secondary heat source will be called into operation. 15

16 Nu-Heat u U N D E R F L O O R & R E N E W A B L E S Heathpark House, Devonshire Road, Honiton, Devon ex14 1sd Tel: Fax: Web: info@nu-heat.co.uk

A Class Air Source Heat Pump User Guide

A Class Air Source Heat Pump User Guide A Class Air Source Heat Pump User Guide IMPORTANT THIS MANUAL MUST BE LEFT WITH THE USER AFTER INSTALLATION 8/60476/0 Issue 1.03 Contents 1: Introduction 1 2: How the Heat Pump Works 1 2.1 Tips and advice

More information

Homeowner Quick Start Guide. Version 2

Homeowner Quick Start Guide. Version 2 Homeowner Quick Start Guide Version 2 Introduction to Your New Mitsubishi Electric Ecodan Heating System This booklet has been created to enable you to quickly personalise the Heating System controls

More information

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump The basics... This guide can help you make an informed

More information

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump Your new Daikin Altherma heat pump In this manual you will find information and guidelines that

More information

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump. English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation... 3 3.2 The user interface

More information

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump. EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...

More information

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The

More information

Operating instructions

Operating instructions Operating instructions Gas condensing boilers MGK-130 MGK-170 MGK-210 MGK-250 MGK-300 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document

More information

ROTEX gas hybrid heat pump. A strong team.

ROTEX gas hybrid heat pump. A strong team. ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat

More information

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents

More information

GUIDE TO AIR SOURCE HEAT PUMPS. Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology

GUIDE TO AIR SOURCE HEAT PUMPS. Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology GUIDE TO AIR SOURCE HEAT PUMPS Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology The most commonly asked questions about Air Source Heat Pumps Q. What are air source

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

UNDERSTANDING CENTRAL HEATING SYSTEMS

UNDERSTANDING CENTRAL HEATING SYSTEMS UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic

More information

AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE

AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE A WARM WELCOME CONGRATULATIONS! Your home is fitted with a unique renewable heating technology, allowing you to benefit from lower running costs

More information

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 English Table of Contents Table of Contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview:

More information

Energy Efficiency HOSPITALITY. www.energia.ie

Energy Efficiency HOSPITALITY. www.energia.ie Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real

More information

Vaillant s plain English guide to. simple, concise and precise

Vaillant s plain English guide to. simple, concise and precise Vaillant s plain English guide to simple, concise and precise Introduction Contents Installing a new boiler 05 Servicing and repairing 13 What s a diverter valve? Why do you need a TRV? And happens when

More information

How to choose a heat pump and use it wisely

How to choose a heat pump and use it wisely How to choose a heat pump and use it wisely Contents How does a heat pump work? 2 Insulating your home 3 Heat loss in the home Not all heat pumps are created equal 4 Choosing a heat pump 4 Choosing by

More information

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................

More information

Air Source Heat Pump Installation and Maintenance Manual

Air Source Heat Pump Installation and Maintenance Manual Air Source Heat Pump Installation and Maintenance Manual Model Numbers: RC090MHXEA RC160MHXEA January 2013 www.samsungehs.co.uk Hendra - January 2013 1 The outdoor unit (boiler) Deciding on Where to Install

More information

Baxi Combi 80e & 105e

Baxi Combi 80e & 105e Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural

More information

Fully Pumped Systems

Fully Pumped Systems Fully Pumped Systems (also see the picture gallery and System Basics) The term for any boiler that uses a pump to move all the heat from the boiler to every part of the system is fully pumped. As a rule

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

User manual. 086U6297 Rev. 9 EN

User manual. 086U6297 Rev. 9 EN User manual Atria Atria Duo Atria Duo Optimum Atria Optimum Comfort Diplomat Diplomat Duo Diplomat Duo Optimum Diplomat Duo Optimum G2 Diplomat Optimum Diplomat Optimum G2 086U6297 Rev. 9 EN Thermia Värme

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store

More information

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.

More information

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5

More information

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

For installation guide see reverse of book

For installation guide see reverse of book USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro + MAKING MODERN LIVING POSSIBLE User Guide DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro + www.heating.danfoss.com The English language

More information

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler User s Operating Instructions & Important Warranty Information Baxi Platinum Combi HE Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house,

More information

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

Ecodan Air Source Heat Pump and Flow Temperature Controller 2 HOMEOWNER STANDALONE Homeowner Information SEPTEMBER 2011 Ecodan Air Source Heat Pump and Flow Temperature Controller 2 Ecodan Air Source Heat Pump Model Number PUHZ-W50VHA(2)-BS PUHZ-W85VHA(2)-BS PUHZ-HW140VHA(2)-BS

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

Housing Solutions Limited. Terms and Conditions. Fixmy Boiler Service

Housing Solutions Limited. Terms and Conditions. Fixmy Boiler Service Housing Solutions Limited Terms and Conditions Fixmy Boiler Service Housing Solutions Limited Crown House, Crown Square Waldeck Road Maidenhead SL6 8BY Tel: 0800 876 6060 Web: www.fixmy.org.uk Terms and

More information

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME UNDERSTANDING HOT WATER SYSTEMS IN THE HOME This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential

More information

User's Instructions. Alpha HE CB25/33 and HE SY25

User's Instructions. Alpha HE CB25/33 and HE SY25 User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:

More information

Users Instructions 0694 51BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

Users Instructions 0694 51BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER Users Instructions 0694 51BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER G.C. NUMBER SABRE 25 HE N 470 94 70 SABRE 29 HE N 470 94 71 SABRE 35 HE N 470 94 72 Contents Introduction Page Dear customer 2

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump your comfort. our world. Daikin Altherma Hybrid Heat Pump Smart heating technology for the best of both worlds Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Forward thinking About

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs

More information

How Ground/Water Source Heat Pumps Work

How Ground/Water Source Heat Pumps Work How Ground/Water Source s Work Steve Kavanaugh, Professor Emeritus of Mechanical Engineering, University of Alabama Ground Source s (a.k.a. Geothermal s) are becoming more common as the costs of energy

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump Daikin Altherma Hybrid Heat Pump Smart technology for the best of both worlds NATIONAL HEAT PUMP 19 JUNE 2014 ICC BIRMINGHAM WINNER Forward thinking Now is the time to rethink the way we heat our homes

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

Continuous flow direct water heating for potable hot water

Continuous flow direct water heating for potable hot water Continuous flow direct water heating for potable hot water An independently produced White Paper for Rinnai UK 2013 www.rinnaiuk.com In the 35 years since direct hot water systems entered the UK commercial

More information

How to choose a heat pump and use it wisely

How to choose a heat pump and use it wisely How to choose a heat pump and use it wisely Contents Introduction 1 The keys to a good heat pump 1 Insulate first 2 Insulation keeps in the heat 2 Plugging up the draughts 2 Funding available 2 How does

More information

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 Report Date: 04/03/2014 Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 About this Advisory Report Energy use in our homes is responsible for almost

More information

BoilerMate SP. benchmark. user instructions A - C L A S S

BoilerMate SP. benchmark. user instructions A - C L A S S A - C L A S S BoilerMate SP user instructions benchmark TM The code of practice for the installation, commissioning & servicing of central heating systems In the interest of continuously improving the

More information

Energy Efficiency. Bars & RestauRants. www.energia.ie

Energy Efficiency. Bars & RestauRants. www.energia.ie Energy Efficiency Bars & RestauRants www.energia.ie 2 Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could

More information

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range

More information

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries

More information

User manual. Atec. 086L0130 Rev. 1 EN

User manual. Atec. 086L0130 Rev. 1 EN User manual Atec 086L0130 Rev. 1 EN Thermia Värme AB reserves the right to make changes to components and specifications without prior notice. 2010 Thermia Värme AB. The Swedish language is used for the

More information

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System TICS - Total Integrated Control Strategy Mid Range System Underfloor Heating & Cooling Control Solutions Energy efficient Heating and cooling TICS - Mid Range System Mid Range System TICS Mid Range Install

More information

Air Source Heat Pump Installation and Maintenance Manual Combi Hybrid

Air Source Heat Pump Installation and Maintenance Manual Combi Hybrid Air Source Heat Pump Installation and Maintenance Manual Combi Hybrid Model Numbers: RC090MHXEA RC160MHXEA www.samsungehs.co.uk G Hendra September 2014 1 Hybrid or Bi-Valent heat pumps A hybrid or Bi-valent

More information

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Baxi Combi Instant 8e & 15e Gas Fired Wall Mounted Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.

More information

Description of functions

Description of functions Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the

More information

Hot water supply, distribution and use

Hot water supply, distribution and use Guidance Leaflet Reducing use Hot supply, distribution and use All businesses use hot in some way, whether for domestic use, in the manufacturing process or for ancillary activities. As there are considerable

More information

Heating system study for Cambrook House, Peasedown St John

Heating system study for Cambrook House, Peasedown St John , Peasedown St John Final Report 26 April 2011 Centre for Sustainable Energy 3 St Peter s Court Bedminster Parade Bristol BS3 4AQ Registered company no. 2219673 t. 0117 934 1400 f. 0117 934 1410 info@cse.org.uk

More information

AQUAREA USER GUIDE FOR BI-BLOC, MONOBLOC & ALL IN ONE

AQUAREA USER GUIDE FOR BI-BLOC, MONOBLOC & ALL IN ONE AQUAREA USER GUIDE FOR BI-BLOC, MONOBLOC & ALL IN ONE WH-ADC _G WH-SDC _F WH-SXC _F WH-SHF _F WH-MDC _F WH-MHF _F AQUAREA USER GUIDE/ FOR BI-BLOC, MONOBLOC AND ALL IN ONE SYSTEMS UK_MANUAL_B.indd 1 29/07/15

More information

Installation & User Instructions

Installation & User Instructions PROVISIONAL COPY Grant ASHE Air Source Heat Pump Air to Water High Efficiency Heat Pump Range Installation & User Instructions Tested to BS EN 14511 Part No. DOC.93 Rev.00 April 2013 STOP! Before continuing

More information

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information

www.the Floor Heating Warehouse.co.uk

www.the Floor Heating Warehouse.co.uk www.the Floor Heating Warehouse.co.uk Underfloor Heating Installation Guide (Grundfoss Pump System) General Overview: Our water based underfloor heating system can be installed by your own plumber or heating

More information

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES

More information

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS 1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding with the installation,

More information

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List Artisan Thermostatic bath shower mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts Contents Page 1. Introduction 03 2. Specification

More information

Rainwater Harvesting

Rainwater Harvesting Rainwater Harvesting With climate change now a reality rather than a speculated possibility, the demand on water resources has gone up, whilst the amount of water available for supply has gone down. Forth

More information

Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS

Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS sustainable solutions under one roof HEATING HOT WATER VENTILATION Hi-Spec Warm Air Heaters Publication No. ZZ 0782-11 June 2012 with System E-T & Basic Control USERS INSTRUCTIONS J25 - G.C. No. 42-416-99

More information

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs. Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs. Fuel for thought Choosing the right heating system for

More information

High Output Boiler Systems

High Output Boiler Systems High Output Boiler Systems Information for Dual System Link up methods For use in GB & IE (Great Britain and Republic of Ireland). This appliance has been certified for use in countries other than those

More information

Boiler Preparation, Start-Up and Shutdown

Boiler Preparation, Start-Up and Shutdown Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

Operating instructions

Operating instructions 6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance

More information

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

ASTACEA4 Inspect complex/central air conditioning systems

ASTACEA4 Inspect complex/central air conditioning systems Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air

More information

Aerona Air Source Heat Pumps

Aerona Air Source Heat Pumps ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

Heat Pumps for Swimming Pools

Heat Pumps for Swimming Pools Page 1 of 5 Heat Pumps for Swimming Pools This factsheet provides members with invaluable information about heat pumps and their use for heating swimming pool water. There is a consumer factsheet already

More information

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

INDIRECT WATER HEATER. Installation and Operating Instruction Manual INDIRECT WATER HEATER Installation and Operating Instruction Manual Maximum supply temperature to heat exchanger must not exceed 180 F (82 C). Safety Warning: Indirect water heaters are heat-producing

More information

Natural geothermal energy.

Natural geothermal energy. ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.

More information

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses? The Only GUY To Call May 2014 412.885.2356 Why are my utility bills so high? What can I do to lower my energy expenses? Did you know... that between 2007 and 2012, the average U.S. household spent more

More information

Thermo Siphon Solar Systems

Thermo Siphon Solar Systems Thermo Siphon Solar Systems Thermo Siphon Solar Systems are a very cost effective way of producing hot water due to their simplicity in design and installation requirements. Usually more common in hotter

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

This section gives you some helpful information and tips on running your home and the equipment in it.

This section gives you some helpful information and tips on running your home and the equipment in it. 67 This section gives you some helpful information and tips on running your home and the equipment in it. Electricity Fuse board (electrical consumer unit) Make sure you know where your fuse board is and

More information

Response: The combi boiler. Response: The fit anywhere combi

Response: The combi boiler. Response: The fit anywhere combi Response: The combi boiler The Ideal Response is a wall mounted, fanned flue combination boiler which serves a home's central heating system and delivers hot water on demand. It has been designed to be

More information

Contract No.: IEE/08/776/SI2.529222

Contract No.: IEE/08/776/SI2.529222 SEasonal PErformance factor and MOnitoring for heat pump systems in the building sector (SEPEMO-Build) Contract No.: IEE/08/776/SI2.529222 Important parameters influencing heat pump systems efficiency

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient

More information

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hot Water. Heat pump water heaters. Residential and Commercial R410a Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating

More information

Design Utility Lever Thermostatic Bath Shower Mixer

Design Utility Lever Thermostatic Bath Shower Mixer Design Utility Lever Thermostatic Bath Shower Mixer Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank

More information

Get more from your hot water

Get more from your hot water Get more from your hot water 3 action sheet Whether you re choosing a new hot water system or using the one you already have, there are some easy ways to reduce your energy use without compromising on

More information

Basic Technology Series

Basic Technology Series Basic Technology Series Fundamentals of Car Air Conditioning 2007 Air Conditioning #003 The Rear Cooler Construction Fan Fan Filter Figure A : Trunk Figure B : Overhead Dual Air-Conditioner In This Issue

More information

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction

More information

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Energy Saving Fact Sheet Air Conditioning

Energy Saving Fact Sheet Air Conditioning Energy Saving Fact Sheet Air Conditioning Get your air conditioning into better shape Everyone wants air conditioning. But don t let your existing system, or one that you re considering installing, burn

More information

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy

More information

Wiring Diagram. Diplomat 400V 3N. www.thermia.com

Wiring Diagram. Diplomat 400V 3N. www.thermia.com www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

FILLING AND PURGING THE SYSTEM

FILLING AND PURGING THE SYSTEM FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation

More information