AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE

Size: px
Start display at page:

Download "AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE"

Transcription

1 AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE

2 A WARM WELCOME CONGRATULATIONS! Your home is fitted with a unique renewable heating technology, allowing you to benefit from lower running costs and a more even temperature throughout your home. An air source heat pump collects and utilises thermal energy from the outside air to heat the home and provide domestic hot water. It does this in the same way that a fridge extracts heat from its inside. It can extract heat from the air even when the outside temperature is as low as -20 C. The heat generated can be used to warm water for radiators, underfloor heating systems or provide domestic hot water in your home. The process is simple, effective and entirely renewable and has been developed specifically for use in the UK and Irish domestic housing markets. In this guide we ll explain how Aeromax generates heat for your home and how to use your system in the most efficient way. Page 1

3 YOUR AEROMAX PLUS AIR SOURCE HEAT PUMP Your Aeromax Plus air source heat pump is designed to heat your home and to provide domestic hot water (DHW). Normally your installer will have ensured that your heat pump has sufficient heating output to provide these services without any supplementary heating being required. You ll find your Aeromax Plus unit close to a wall outside your property. It can also be mounted off the ground. SOLAR THERMAL PANELS CENTRAL HEATING RADIATORS DOMESTIC HOT WATER UNDERFLOOR HEATING DOMESTIC HOT WATER CYLINDER AEROMAX PLUS HEAT PUMP Page 2

4 HOW DOES IT WORK? 1. EVAPORATOR Aeromax Plus Air Source Heat Pumps provide thermodynamic heating by means of a vapour compression cycle. In the same way that a fridge uses refrigerant to extract heat from the inside to keep the food cool, air source heat pump extracts heat from the outside air, and uses it to heat the home through radiators, underfloor system or provide domestic hot water. It can extract heat from the air even when the outside temperature is as low as -20 C. 2 The evaporator collects heat from the outside air, which is then drawn into the unit by the fan through the evaporator fins and expelled through the front grille. The evaporator has liquid refrigerant passing through it, which is at a considerably lower temperature than the outside air, therefore the air gives up its heat to the refrigerant, which then vaporises. 2. EOMPRESSOR This preheated vapour now travels to OUTSIDE AIR 3 INTERNAL HEATING the compressor where it is compressed and upgraded to a much higher temperature. HEAT PUMP 3. CONDENSER (heat exchanger) 1 Every air source heat pump has four main parts: 1. Evaporator 2. Eompressor 3. Condenser (heat exchanger) 4. Expansion device 4 The hot vapour now enters the condenser where it is surrounded by water from the heating system. The heat is given up to the cooler water and the now cooler refrigerant returns to its former liquid state but still under high pressure from the compressor. 4. EXPANSION DEVICE Although Aeromax Plus is powered by electricity, when it is installed and designed correctly can often result in the system costing less to run than systems heated by oil, LPG, electricity or coal. Your heating costs will depend on how you use your heating or hot water and the temperature of your radiators. Aeromax Plus is cost-effective to use all year round, but you can ensure it is at its most efficient by running your radiators or underfloor heating at lower temperatures. This high pressure is then released by passing the liquid through the expansion device and from there it returns to the evaporator and the cycle starts again. Page 3

5 HOW DO I USE IT? The Aeromax Plus heat pump is designed to operate with a standard heating time switch and programmable room thermostat, providing space heating or DHW according to demand. The unit has two modes of operation: one for space heating through underfloor heating or radiators adjustable between 35 C and 55 C and a second for DHW preset at 60 C. We recommend that you review the electricity tariffs from all suppliers in your area and select one that will give you the optimum economy in relation to your lifestyle and heating demand HEATING AND DOMESTIC HOT WATER SYSTEM CONTROLS Your heating system is controlled by a programmable room thermostat that allows you to choose when to have your heating on and what temperature it should be when it is on. A time switch allows you to choose when you want to make hot water. The programmable room thermostat controls the temperature of the main living area while thermostatic radiator valves control the temperatures of the radiators in other rooms. The Aeromax Plus radiator system works at a lower surface temperature than traditional central heating. This means that your radiators will take a little longer to warm up your home but will give you a more even comfortable temperature. Normally your installer will have ensured that your radiators are correctly sized for operation with a heat pump. Your heat pump supplies Domestic Hot Water at between 50ºC - 55ºC. This is stored in the special hot water cylinder provided with your heat pump to ensure that you always have hot water on tap. Kingspan recommend that the hot water cylinder thermostat is set between 55/60 degrees C. The cylinder immersion heater should be set at 60ºC - 65ºC. Page 4

6 SYSTEM CONTROLS SETTING YOUR HEATING The programmable room thermostat lets you choose what times you want the heating to be on, and what temperature it should reach while it is on. This will allow you to select different temperatures in your home at different times of the day (and days of the week) to meet your particular needs. Weekdays (Mon-Fri) Event Time Temp. C 1 06: : : : : :30 18 Weekend (Sat-Sun) Event Time Temp. C 1 07: : : : : :30 18 SETTING YOUR HOT WATER The hot water and radiator systems cannot run at the same time so we recommend that you set your hot water to come on min. before you need it. The hot water timings given in the tables below allow for the immersion heater to beactivated after the hot water cycle in the morning. This will sanitise the tank temperature to between 60-65ºC. Typical winter settings for the programmable room thermostat and hot water time switch are illustrated below. Event No Hot water Mon - Fri Sat - Sun 1 1st ON 03:30 05:00 2 1st OFF 05:00 06:30 3 2nd ON 15:00 15:00 4 2nd OFF 15:50 15:50 Page 5

7 RADIATOR VALVES (TRV S) UNDERFLOOR HEATING & THERMOSTATIC RADIATOR VALVES (TRV S) Some of your radiators have thermostatic valves which allow you to vary the temperature in different areas of your home. You may, for example, prefer to keep your bedrooms cooler than your living room. Underfloor heating on the ground floor is normally controlled by room thermostats. This allows you to have different room temperatures if preferred. AUTOMATIC DEFROST When moist air comes into contact with the Aeromax Plus s evaporator, it will ice up in much the same way as ice builds up in your refrigerator. Defrosting the evaporator is a normal part of the Aeromax Plus operation in colder weather and normally takes place for about 4 minutes per hour. When defrosting, the fan will stop and water vapour may be seen rising from the heat exchanger. This is normal and is not a cause for concern. SAFETY PRECAUTIONS 1. Do not stand on the heat pump for any reason. 2. Do not allow children to poke sticks or other objects through the front grille into the fan as this 3. Outer panels should only be removed by a qualified service engineer. SERVICING We recommend that an annual service of the Aeromax Plus air source heat pump is carried out, should you require further details on service packages please contact us. You are advised to check occasionally that there is no debris around the heat pump which may get drawn into, or obstruct, the fans or the evaporator coils of the unit. Page 6

8 ADVANCED CONTROLLER ADVANCED CONTROLLER / COMFORT MODULE (HYDRO BOX) SCREEN INDICATOR Advanced Controller /Comfort Module (Hydro box) screen indicators In some cases your system may be fitted with an advanced controller or a comfort module with auxiliary heaters that also houses an advanced controller. Normally, the advanced controller or comfort module will have been configured by your installer and should require no user intervention. An exception to this may be if the system develops a fault. Details of the main screen icons on the advanced controller are given on the next page. Item 6 shows the Alarm icon. If this becomes active please refer to your advanced controller manual or comfort module manual to access the parameter table and identify the fault code System mode off Room air temperature Area Time Display Area Outdoor temperature Day of the week Alarm Indicator System is using home settings System is using away settings AM or PM indicator for current time System is using sleep settings Relative humidity Percentage Heat Mode Keypad is locked (no padlock means unlocked) Schedule Activated Celsius Auxiliary Heat Source Heat Pump Active Domestic Hot Water Page 7

9 FREQUENTLY ASKED QUESTIONS 1. MY HEAT PUMP IS RUNNING BUT THE RADIATORS ARE ONLY LUKE WARM. WHY? Heat pumps can only supply maximum temperatures of C to the heating system. This is much lower than the C supplied by a fossil fuel boiler. Therefore, the radiators will feel cooler. Also, the heat pump is usually programmed with a climatic curve that reduces the output temperature as the outside air becomes warmer. This reduces energy consumption but will also result in radiators only feeling luke warm if it is warm outside. 2. I HAVE UNDERFLOOR HEATING. WHY DOES IT TAKE SO LONG TO WARM UP? Underfloor heating is ideal for heat pumps as it works at lower temperatures than radiators and this improves the efficiency of the heat pump. However, it is important to understand the differences between underfloor heating and radiators. Underfloor heating is a radiant heating system. It works by heating up a large mass of concrete under the floor and this then radiates heat to the room above. Heating a large mass of concrete can take a long time but when it is warm it can supply heat for several hours and only needs topped up. Therefore, underfloor heating should not be turned off for long periods. 3. THE FANS ARE RUNNING ON MY HEAT PUMP BUT STEAM OR SMOKE SEEMS TO BE COMING OUT. WHY? When the heat pump is running it draws in air over the evaporator coils and removes energy from this air. This means that the exhaust air blown out by the fans is colder than the surrounding air. When this cold dry air comes into contact with relatively warmer moist air then depending on the air temperature condensation may be formed. This condensation will give the appearance of smoke or steam coming out from the fans. 4. THE FANS ARE NOT RUNNING BUT MY HEAT PUMP IS ON AND A LOT OF WATER AND STEAM IS COMING OUT. WHY? When the heat pump is defrosting it has to heat up the evaporator coils to melt the ice formed on them. To perform the defrosting quickly the evaporator coils are heated to a high temperature. This can result in some of the melt water being turned to steam. As the ice melts quickly it will appear that a lot of water is running out. Page 8

10 TROUBLE SHOOTING The diagnostic indicator for the air source heat pump will be located indoors in a visible place. The green lights shows that the power is on to the heat pump. The red alarm light will flash in the event of a problem. If this occurs count the number of flashes between pauses and use the fault code table to determine the fault. SYSTEM TEST The error code can be identified from the flashing LED on the Diagnostic Indicator using the following table. In the case of more than one error, the error with the highest priority will be displayed until it is resolved. In the case of an error the LED flashes a numbers times equal to the error code at a frequency of 1Hz and then remains off again for 6 seconds. If the error code has 2 digits, the flashing is interrupted for 2 seconds between the first and second digits. EXAMPLE: error 23: 2 flashes of 1 second each. Off for 2 seconds. 3 flashes of 1 second each. Off for 6 seconds. The cycle repeats until the LED turns off because the problem is resolved or if an error with higher priority occurs. FAULT CODE CODE DESCRIPTION 3 Enter Water Temperature Thermistor (EWT) Failure/Out of Range 4 Actual Refrigerant Temperature Thermistor BPHE (TR) Failure/Out of Range 5 Air Thermistor of GMC 6 Loss communication to NUI control 7 NUI control Room Thermistor 8 Unit Capacity Mismatch 9 Flow Switch error / Water Pump 10 EEProm Corrupt 11 Air temperature higher than Stop Heat 12 Air temperature lower than Stop Cool 13 Loss Communication to RS485 (system configuration type 6) 14 Loss of Signal From inverter board / High Temperature Release (Thermostat on compressor: 120 ± 4 C) 15 Exit water Temperature Thermistor (LWT) Failure/Out of Range 17 Inverter Air Thermistor (TO) Failure/Out of Range 18 G-Tr inverter short circuit protection 20 Compressor position Detection Circuit error 21 Inverter Current Sensor error 22 Heat Exchanger Sensors (TE) / (TS) Failure/Out of Range 23 Discharge Temperature Sensor (TD) (TD > 100 ± 4 C) 24 Outdoor Fan motor error 26 Other inverter board error 27 Compressor Lock 28 Discharge Temperature error Failure/Out of Range 29 Compressor Breakdown 30 Other inverter board error To reset the unit after an error has been cleared turn off the mains supply for 10 seconds and turn on again. Page 9

11 GUARANTEE During the period of guarantee we will, at our option, repair or replace your Aeromax Plus heat pump free of charge where it suffers a mechanical or electrical breakdown resulting from defective workmanship or materials, subject to the following conditions and exclusions: 1. The guarantee period commences from the date of commissioning. This must be recorded by the installer on the commissioning sheet. Without proof of purchase, i.e. an invoice or completed commissioning sheet, the guarantee period will be taken to commence from the date of manufacture, as detailed by the serial number on the appliance data plate. 2. The guarantee period for your heat pump is 2 years. 3. If the heating system fa ils, you should call the installer who will identify whether the problem lies with the heat pump or some other part of the system. They may be able to resolve the problem on the spot. If the problem is found to lie with the heat pump, they should telephone our Service Department on in the UK and Northern Ireland or for ROI. If the problem cannot be solved over the phone, they will arrange a visit by an authorised Aeromax Plus service agent to inspect and repair or, where in our sole opinion repair is not economic, arrange to replace the heat pump. 4. Your Aeromax Plus heat pump must not be removed from its place of installation at your property without our prior consent. 5. We reserve the right to charge a call-out fee: a. Where the problem is found not to lie with the heat pump. b. Failure to notify us of cancellation of an agreed appointment prior to our engineer s visit. c. The heat pump is outside the guarantee period. 6. The guarantee does not cover other costs or expenses caused or arising as a result of the failure of your heat pump. 7. The guarantee does not apply to any costs incurred during delays in fixing reported faults. 8. The guarantee applies to Aeromax Plus heat pumps installed in the UK and the Republic of Ireland. THE GUARANTEE DOES NOT APPLY IF: 1. The heat pump and associated equipment has been incorrectly sized for the application. 2. The heat pump and associated equipment has not been installed and commissioned in complete accordance with the procedures defined in the Aeromax Plus Installation Manual. 3. The heat pump and associated equipment has been worked upon or has been adjusted by anyone other than a person authorized to do so by Kingspan Environmental. 4. The heat pump and associated equipment has suffered frost, flood or malicious damage. IMPORTANT: Kingspan Environmental guarantee is subject to the homeowner registering with the Kingspan Environmental Customer Service Department within 30 days of commissioning / occupation if new build to confirm: Product Make / Model Details of installation Please complete the registration card provided with the unit and return to: Customer Service Department, Kingspan Environmental, Tadman Street, Wakefield, WF1 5QU, UK FOR PRODUCT REGISTRATION OR FURTHER INFORMATION WE CAN BE WE CAN BE CONTACTED IN THE FOLLOWING WAYS. . technicaluk@kingspan-renewables.com Tel (UK) Tel: (ROI) If you do not register the Product then Kingspan Environmental Guarantee is limited to twelve months from the date of commissioning. The product must be maintained by a competent person* within 12 months after commissioning, and thereafter at 12 monthly intervals. Kingspan Environmental reserves the right to seek evidence of this maintenance to our reasonable satisfaction before approving any guarantee servicing / repairs. PLEASE NOTE: this guarantee excludes all pipework and connections and excludes any ancillary equipment that may be connected to the product. (Ex: descaling equipment, water softeners). *A competent person is a business that has been adjudged by an accredited body (examples of which are NICEIC and BPEC) to be sufficiently competent to self-certify that its work complies with Document (G) Part 3 of the Building Regulations of England and Wales. * May Include SEI registered installers and/or FAS trained plumbers who have completed the renewables technology module. Page 10

12 Contact us now for further information Wakefield Office Tadman Street, Wakefield West Yorkshire WF1 5QU T F sales@kingspan-renewables.com Portadown Office 180 Gilford Road, Portadown Co. Armagh BT63 5LF T F contact@kingspanenviro.co.uk

A Class Air Source Heat Pump User Guide

A Class Air Source Heat Pump User Guide A Class Air Source Heat Pump User Guide IMPORTANT THIS MANUAL MUST BE LEFT WITH THE USER AFTER INSTALLATION 8/60476/0 Issue 1.03 Contents 1: Introduction 1 2: How the Heat Pump Works 1 2.1 Tips and advice

More information

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

Ecodan Air Source Heat Pump and Flow Temperature Controller 2 HOMEOWNER STANDALONE Homeowner Information SEPTEMBER 2011 Ecodan Air Source Heat Pump and Flow Temperature Controller 2 Ecodan Air Source Heat Pump Model Number PUHZ-W50VHA(2)-BS PUHZ-W85VHA(2)-BS PUHZ-HW140VHA(2)-BS

More information

Homeowner Quick Start Guide. Version 2

Homeowner Quick Start Guide. Version 2 Homeowner Quick Start Guide Version 2 Introduction to Your New Mitsubishi Electric Ecodan Heating System This booklet has been created to enable you to quickly personalise the Heating System controls

More information

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump The basics... This guide can help you make an informed

More information

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump Your new Daikin Altherma heat pump In this manual you will find information and guidelines that

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

Single Zone LCD Thermostat Operating Instructions

Single Zone LCD Thermostat Operating Instructions Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip

More information

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump. EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...

More information

REMOTE CONTROL MANUAL

REMOTE CONTROL MANUAL REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read

More information

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

6 YEAR * PAYBACK A GUIDE TO DOMESTIC RENEWABLE HEAT INCENTIVE (RHI) SOLAR THERMAL SOLUTIONS

6 YEAR * PAYBACK A GUIDE TO DOMESTIC RENEWABLE HEAT INCENTIVE (RHI) SOLAR THERMAL SOLUTIONS 6 YEAR * PAYBACK A GUIDE TO DOMESTIC RENEWABLE HEAT INCENTIVE () SOLAR THERMAL SOLUTIONS RENEWABLE HEAT INCENTIVE KINGSPAN SOLAR RENEWABLE HEAT INCENTIVE () EXPLAINED The Renewable Heat Incentive is intended

More information

service breakdown emergency 3in1 Plan What the SGS Service Plan provides What happens if you have a breakdown Cover provided by the Plan Dear

service breakdown emergency 3in1 Plan What the SGS Service Plan provides What happens if you have a breakdown Cover provided by the Plan Dear 3in1 Plan Dear As per our recent conversation, the SGS Service Plan offers complete peace of mind because for a small premium your central heating equipment will be serviced and covered in the event of

More information

UNDERSTANDING CENTRAL HEATING SYSTEMS

UNDERSTANDING CENTRAL HEATING SYSTEMS UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify

Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2

More information

Energy Efficiency HOSPITALITY. www.energia.ie

Energy Efficiency HOSPITALITY. www.energia.ie Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real

More information

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump. English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation... 3 3.2 The user interface

More information

Housing Solutions Limited. Terms and Conditions. Fixmy Boiler Service

Housing Solutions Limited. Terms and Conditions. Fixmy Boiler Service Housing Solutions Limited Terms and Conditions Fixmy Boiler Service Housing Solutions Limited Crown House, Crown Square Waldeck Road Maidenhead SL6 8BY Tel: 0800 876 6060 Web: www.fixmy.org.uk Terms and

More information

ROTEX gas hybrid heat pump. A strong team.

ROTEX gas hybrid heat pump. A strong team. ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat

More information

GUIDE TO AIR SOURCE HEAT PUMPS. Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology

GUIDE TO AIR SOURCE HEAT PUMPS. Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology GUIDE TO AIR SOURCE HEAT PUMPS Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology The most commonly asked questions about Air Source Heat Pumps Q. What are air source

More information

Dehumidifier D 850E. - Instruction manual version 02

Dehumidifier D 850E. - Instruction manual version 02 Dehumidifier D 850E - Instruction manual version 02 Content 1. Description of dehumidifier 1.1. General data 1.2. Technical data 2. Operation and usage 2.1. Usage 2.2. Location and installation 2.3. Preparing

More information

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 English Table of Contents Table of Contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview:

More information

How to choose a heat pump and use it wisely

How to choose a heat pump and use it wisely How to choose a heat pump and use it wisely Contents How does a heat pump work? 2 Insulating your home 3 Heat loss in the home Not all heat pumps are created equal 4 Choosing a heat pump 4 Choosing by

More information

User manual. 086U6297 Rev. 9 EN

User manual. 086U6297 Rev. 9 EN User manual Atria Atria Duo Atria Duo Optimum Atria Optimum Comfort Diplomat Diplomat Duo Diplomat Duo Optimum Diplomat Duo Optimum G2 Diplomat Optimum Diplomat Optimum G2 086U6297 Rev. 9 EN Thermia Värme

More information

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Table Z. Troubleshooting Chart for Air Conditioners. Cause Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause

More information

Natural geothermal energy.

Natural geothermal energy. ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.

More information

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries

More information

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro + MAKING MODERN LIVING POSSIBLE User Guide DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro + www.heating.danfoss.com The English language

More information

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00 RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls

More information

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target 4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection

More information

For installation guide see reverse of book

For installation guide see reverse of book USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

Hybrid heat pumps. saving energy and reducing carbon emissions

Hybrid heat pumps. saving energy and reducing carbon emissions Hybrid heat pumps saving energy and reducing carbon emissions Bart Aspeslagh Product planning and new technology manager, Daikin Europe NV. aspeslagh.b@daikineurope.com Stefanie Debaets Design engineer,

More information

HomeServices Terms and Conditions

HomeServices Terms and Conditions HomeServices Terms and Conditions Contents Definitions 03 The Contract 04 Start date 04 General Exclusions 11 Payment 12 Cancellation 13 Appointments 16 Product Renewal 16 Changes to contract 16 Safety

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

Module 2.2. Heat transfer mechanisms

Module 2.2. Heat transfer mechanisms Module 2.2 Heat transfer mechanisms Learning Outcomes On successful completion of this module learners will be able to - Describe the 1 st and 2 nd laws of thermodynamics. - Describe heat transfer mechanisms.

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

Baxi Combi 80e & 105e

Baxi Combi 80e & 105e Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural

More information

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM AIR HANDLING UNITS... 1 CHILLERS... 2 COOLING TOWERS... 2 CLOSED LOOP COOLERS... 2 MISCELLANEOUS SUPPLY FANS...

More information

The natural ombination

The natural ombination The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,

More information

Troubleshooting Your Refrigerator

Troubleshooting Your Refrigerator Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.

More information

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.

More information

AQUAREA USER GUIDE FOR BI-BLOC, MONOBLOC & ALL IN ONE

AQUAREA USER GUIDE FOR BI-BLOC, MONOBLOC & ALL IN ONE AQUAREA USER GUIDE FOR BI-BLOC, MONOBLOC & ALL IN ONE WH-ADC _G WH-SDC _F WH-SXC _F WH-SHF _F WH-MDC _F WH-MHF _F AQUAREA USER GUIDE/ FOR BI-BLOC, MONOBLOC AND ALL IN ONE SYSTEMS UK_MANUAL_B.indd 1 29/07/15

More information

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler User Guide and Important Warranty Information Suprima 30L - 100L Wall Mounted Fan Assisted Balanced Flue Gas Boiler These instructions are for use with boilers whose serial numbers end C (or higher) only.

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

Building Energy Systems. - HVAC: Heating, Distribution -

Building Energy Systems. - HVAC: Heating, Distribution - * Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

Impact of Control System Technologies on Industrial Energy Savings

Impact of Control System Technologies on Industrial Energy Savings Impact of Control System Technologies on Industrial Energy Savings Priyam Parikh Industrial Assessment Center Texas A&M University Bryan P. Rasmussen Industrial Assessment Center Texas A&M University http://farolconsulting.com/?page_id=110

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

CGC s Hybrid System Loop Control

CGC s Hybrid System Loop Control verview The CGC Group Hybrid Heat Pump System does NT operate with the same fluid loop temperatures as a conventional reversing Water Source Heat Pump system. The CGC system differs from a WSHP system

More information

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

AIR CONDITIONER WALL CONTROLLER

AIR CONDITIONER WALL CONTROLLER AIR CDITIER WALL CTROLLER Operating Instructions Controller Model Numbers LM7 LM7-D LM4 Please Read This Manual Congratulations on your purchase of an ActronAir air conditioning system. This unit has been

More information

Refrigeration Basics 101. By: Eric Nelson

Refrigeration Basics 101. By: Eric Nelson Refrigeration Basics 101 By: Eric Nelson Basics Refrigeration is the removal of heat from a material or space, so that it s temperature is lower than that of it s surroundings. When refrigerant absorbs

More information

To find out more about installing a heat pump call 0300 123 1234 or visit energysavingtrust.org.uk

To find out more about installing a heat pump call 0300 123 1234 or visit energysavingtrust.org.uk A buyer s guide to heat pumps To find out more about installing a heat pump call 0300 123 1234 or visit energysavingtrust.org.uk What are heat pumps? Heat pumps extract available heat from a natural source

More information

Information Guide Domestic Air Source Heat Pumps

Information Guide Domestic Air Source Heat Pumps Information Guide Domestic Air Source Heat Pumps Issue 41 Domestic Air Source Heat Pumps This is an independent guide produced by Mitsubishi Electric to enhance the knowledge of its customers and provide

More information

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler User s Operating Instructions & Important Warranty Information Baxi Platinum Combi HE Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house,

More information

User's Instructions. Alpha HE CB25/33 and HE SY25

User's Instructions. Alpha HE CB25/33 and HE SY25 User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:

More information

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D) Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2013 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Heat

More information

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Guidance on how to comply with the 2013 Building Regulations Part L

Guidance on how to comply with the 2013 Building Regulations Part L Guidance on how to comply with the 2013 Building Regulations Part L Version 1.0 6 April 2014 This guide supports the official guidance covering the control of gas and oil fired wet central heating installations

More information

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS INTRODUCTION 1. There are no general EU regulations and standards for outdoor swimming pool heating. Local regulations in the member countries are covering most

More information

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Baxi Combi Instant 8e & 15e Gas Fired Wall Mounted Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.

More information

HEATING, VENTILATION & AIR CONDITIONING

HEATING, VENTILATION & AIR CONDITIONING HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating

More information

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,

More information

Direct Fresh Air Free Cooling of Data Centres

Direct Fresh Air Free Cooling of Data Centres White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy

More information

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold Bradlee Boilers Ltd Instruction Manual for starting up Bradlee Hire Boiler from Cold To be read in conjunction with Bradlee Boiler guide to Commissioning Boilers Document Ref: HM001 1. Ensure that all

More information

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...

More information

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME UNDERSTANDING HOT WATER SYSTEMS IN THE HOME This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

Heat Pumps for Swimming Pools

Heat Pumps for Swimming Pools Page 1 of 5 Heat Pumps for Swimming Pools This factsheet provides members with invaluable information about heat pumps and their use for heating swimming pool water. There is a consumer factsheet already

More information

Heat Pump USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL HEAT PUMP

Heat Pump USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL HEAT PUMP Heat Pump USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL HEAT PUMP NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME TO EFFICIENT YEAR-ROUND

More information

Daikin Altherma. hybrid heat pump. The natural combination

Daikin Altherma. hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Why choose Daikin? As an industry leader, Daikin combines broad experience, technical innovation and responsive customer service to help you meet

More information

Energy Saving Fact Sheet Air Conditioning

Energy Saving Fact Sheet Air Conditioning Energy Saving Fact Sheet Air Conditioning Get your air conditioning into better shape Everyone wants air conditioning. But don t let your existing system, or one that you re considering installing, burn

More information

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System TICS - Total Integrated Control Strategy Mid Range System Underfloor Heating & Cooling Control Solutions Energy efficient Heating and cooling TICS - Mid Range System Mid Range System TICS Mid Range Install

More information

Operating instructions

Operating instructions 6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance

More information

Best Practice Guide. Heat Pump Technologies

Best Practice Guide. Heat Pump Technologies Best Practice Guide Heat Pump Technologies Objectives of this Guide: Whether installing a heat pump in a new or existing dwelling, the initial capital investment will generally be greater than for a conventional

More information

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump your comfort. our world. Daikin Altherma Hybrid Heat Pump Smart heating technology for the best of both worlds Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Forward thinking About

More information

Air Source Heat Pump Installation and Maintenance Manual

Air Source Heat Pump Installation and Maintenance Manual Air Source Heat Pump Installation and Maintenance Manual Model Numbers: RC090MHXEA RC160MHXEA January 2013 www.samsungehs.co.uk Hendra - January 2013 1 The outdoor unit (boiler) Deciding on Where to Install

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump Daikin Altherma Hybrid Heat Pump Smart technology for the best of both worlds NATIONAL HEAT PUMP 19 JUNE 2014 ICC BIRMINGHAM WINNER Forward thinking Now is the time to rethink the way we heat our homes

More information

User manual. Atec. 086L0130 Rev. 1 EN

User manual. Atec. 086L0130 Rev. 1 EN User manual Atec 086L0130 Rev. 1 EN Thermia Värme AB reserves the right to make changes to components and specifications without prior notice. 2010 Thermia Värme AB. The Swedish language is used for the

More information

Vaillant s plain English guide to. simple, concise and precise

Vaillant s plain English guide to. simple, concise and precise Vaillant s plain English guide to simple, concise and precise Introduction Contents Installing a new boiler 05 Servicing and repairing 13 What s a diverter valve? Why do you need a TRV? And happens when

More information

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW is a multi-energy hybrid system that offers the consumer the ability to heat the house, and if necessary produce DHW also affect the environments. The platform, designed to offer innovative solutions for

More information

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the

More information

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents

More information

Create the right atmosphere with renewables.

Create the right atmosphere with renewables. The complete ROTEX heat pump product range Create the right atmosphere with renewables. ROTEX air-to-water and ground source heat pumps for new build and modernisation. The inexhaustible heat source on

More information

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information