1 City of Penticton 171 Main St. Penticton B.C. V2A 5A9 This handout is to inform you of Bylaws and Provincial Regulations regarding Vacation Rentals. Please note that as an Operator/Owner of a Vacation Rental within the City of Penticton you must comply with all City of Penticton Bylaws & Provincial Regulations. Failure to comply with the Bylaws shall be deemed Non- Compliance and may result in the suspension of your Business Licence and/or fines. If you have any questions please feel free to contact us at or come in and speak with us directly at City Hall Main St. Penticton. Goodluck with your venture! Zoning Regulations Please ensure the following Zoning regulations are met. Ownership A residential dwelling unit being proposed for vacation rental shall only be rented out by an owner of the property. A tenant may not sublet a property for the purpose of Vacation Rentals. If the Registered owner ceases to be the owner, the use may not be continued by a subsequent owner until the application for a new Business Licence has been approved by the City. Development No structural alterations or additions to a dwelling unit to facilitate a Vacation Rental shall be Regulations undertaken that alters the residential character of the dwelling. No exterior signage advertising the Vacation Rental is permitted A site containing a single detached dwelling and an approved secondary suite or carriage house can be used for the purpose of vacation rentals, * Subject to the property owner living on the subject property. (Zoning Bylaw ) * Owner is not required to reside on subject property if no secondary suite or carriage house. The owner of a Bed and Breakfast can be used as a Vacation Rental and can be rented out to no more than 5 people while the owner is home. The owner of a Vacation Rental can have a Minor/Major Home Occupation and also a Vacation Rental Licence. Operation of The owner shall ensure that the renters do not create any form of nuisance for surrounding Vacation residents, such as, noise, light or traffic that is disruptive to the surrounding residents quite Rental enjoyment of their properties. A maximum of two (2) persons per bedroom, or a group of not more than five (5) persons is permitted per vacation rental unit, whichever is less. Building Regulations Please ensure the Vacation Rental is in compliance with the BC Building Code and City of Penticton Building Bylaw. BC Building Smoke and Carbon Monoxide Detectors, means of egress from bedrooms, stairs, guards and Code handrails must be provided as per the current BC Building Code. Plumbing, Mechanical, Electrical & Gas *Please refer to attachment A for basic c life safety code requirements* In the case of secondary suites or carriage houses being rented out for Vacation Rentals, proper building permits have been acquired and maintenance of fire separations are maintained. Systems are in good working order and conform to applicable standards outlined with the BC Building Code, BC Safety Authority and other applicable regulations. Cross Connection controls may be required to be reviewed for potential health hazards. Please refer to the City s Cross Connection Control program for potential hazards via this link
2 (Cross Connection Control) or phone the Environmental Coordinator at Private Pools & Hot tubs Alterations to heating and cooling appliances, including wood or gas fireplaces, are to be reviewed with the Building Department and may also require BC Safety approvals. Please contact the BC Safety Authority at or via this Link Private Pools, Hot tubs and any artificial pool in which the depth of the water could retain at least 600mm (1.968 ft.) meets security fencing and guards in accordance with the City Building Bylaw Fire Department Fire Extinguisher Smoke Alarms A 5lb ABC fire extinguisher must be located on each floor and is to be mounted in an accessible location (do not store in cabinets). Ensure that the proper maintenance protocol is completed. Smoke alarms are hard wired and interconnected on every level. Smoke Alarms & Carbon Monoxide Detectors as per requirements of the current BC Building Code. A log should be maintained indicating monthly testing of each smoke alarm for annual review by the City. Fire Safety Plan A Fire Safety Plan must be placed in readily accessible location (back of the main door). The Fire Safety is to clearly state Call 911, address of property, alert others in building and instructions to evacuate and close doors. A Diagram should be provided showing the exit routes and fire extinguisher locations. Please contact the Fire Department at for further information. Strata Units The owner(s) of strata units are required to review the rules and regulations of their strata corporation to determine if Vacation Rentals are permitted. Noise Regulations As per the Good Neighbour Bylaw Section 6.7, owners are responsible for ensuring that: (a) No person shall play or operate any radio, stereophonic equipment or other instrument or any apparatus for the production or amplification of sound either in or on private premises or on any highway or other public place in such a manner as to disturb the quiet, peace, rest, enjoyment, comfort or convenience of any person or persons in the neighbourhood or vicinity of those premises or place; (b) No person being the owner, occupier or tenant of Real Property shall allow or permit his real property to be used by a person or persons for playing or operating any radio or stereophonic equipment or other instrument or other apparatus for the production or amplification of sound in such a manner as to disturb the quiet, peace, rest, enjoyment, comfort or convenience of any person or persons in the neighbourhood or vicinity of said real property; (c) Subject to Sub-Section 6.2 (c), no person shall own, keep or harbor any animal or bird, but excluding dogs, which by its cries or sounds unduly disturbs the peace, quiet, rest or tranquility of the surrounding neighbourhood or of persons in the vicinity; (d) No person may operate, or cause, suffer or permit the operation of, any motorized law-grooming or garden equipment in the City between the hours of 2200 hours and 0700 hours; (e) Subject to section 6.3, no person in the City shall, on any day before 0700 hours or after 2200 hours, construct, erect, reconstruct, alter, repair or demolish any building, structure or thing, or excavate or fill in land in any manner which causes noises, or sounds in or on a highway or elsewhere in the City which disturbs or tends to disturb, the quiet, peace, rest, enjoyment, comfort or convenience of any person or persons in the neighbourhood or vicinity.
3 Snow and Solid Waste Please ensure the occupants and/or guests comply with City s Snow Removal, Parking and Please ensure the occupants comply with the, Solid Waste Collection Bylaw No and ensure that Garbage, Recyclable Materials, and Yard and Garden Waste are stored and placed in a sanitary manner, and in a way that will not injure persons handling them and comply with regulations for curb pick-up. Business Licence Bylaw The vacation rental Business Licence placard must be permanently posted in a prominent location and that the Licence must be renewed on an annual basis. Inspection of Premises Section 6.0 The Licence Inspector may inspect the Premises for which a Business Licence Application is made or a Business Licence is issued and such Inspection shall be for the purpose of and limited to: o Observe that the Business Category and/or Business Type is in accordance with the City Zoning Bylaw. o Observe the Business and Premises for compliance with the City Building Bylaw, and the City Fire and Life Safety Bylaw. Yearly Renewal The Business licence must be renewed on a yearly basis and the Licence Inspector may attend to audit the premise to ensure regulations within the City Bylaws are maintained. Contacts Building Department 171 Main St. (250) buildinginfo@penticton.ca Fire Department 250 Nanaimo Ave W (250) Public Works Department Garbage & Recycling 616 Okanagan Ave E. (250) Bylaw Enforcement 171 Main St (250) If you have any further questions please contact the Business Licence Clerk within the Development Services Department, 2 nd Floor City Hall or call us at
4 Attachment A BC Building Code Requirements for Vacation Rentals (Excerpts from 2012 BCBC) Egress from Bedrooms Egress Windows or Doors for Bedrooms 1) Except where the suite is sprinklered, each bedroom or combination bedroom shall have at least one outside window or exterior door openable from the inside without the use of keys, tools or special knowledge and without the removal of sashes or hardware. 2) The window referred to in Sentence (1) shall a) provide an unobstructed opening of not less than 0.35 m2 in area with no dimension less than 380 mm, and b) maintain the required opening during an emergency without the need for additional support. 3) Where a window required in Sentence (1) opens into a window well, a clearance of not less than 760 mm shall be provided in front of the window. 4) Where the sash of a window referred to in Sentence (3) swings towards the window well, the operation of the sash shall not reduce the clearance in a manner that would restrict escape in an emergency. 5) Where a protective enclosure is installed over the window well referred to in Sentence (3), the enclosure shall be openable from the inside without the use of keys, tools or special knowledge of the opening mechanism Location of Smoke Alarms 1) Within dwelling units, sufficient smoke alarms shall be installed so that a) there is at least one smoke alarm installed on each storey, including basements, and b) on any storey of a dwelling unit containing sleeping rooms, a smoke alarm is installed i) in each sleeping room, and ii) in a location between the sleeping rooms and the remainder of the storey, and if the sleeping rooms are served by a hallway, the smoke alarm shall be located in the hallway. 2) A smoke alarm required by Sentence (1) shall be installed in conformance with CAN/ULC-S553, Installation of Smoke-Alarms. 3) Smoke alarms required in Article and Sentence (1) shall be installed on or near the ceiling Carbon Monoxide Alarms 1) This Article applies to every building that contains a residential occupancy and that also contains a) a fuel-burning appliance, or b) a storage garage. 2) Carbon monoxide (CO) alarms required by this Article shall a) conform to CAN/CSA-6.19, Residential Carbon Monoxide Alarming Devices, b) be equipped with an integral alarm that satisfies the audibility requirements of CAN/CSA-6.19, Residential Carbon Monoxide Alarming Devices, c) have no disconnect switch between the overcurrent device and the CO alarm, where the CO alarm is powered by the dwelling unit's electrical system, and d) be mechanically fixed at a height recommended by the manufacturer's instructions.
5 3) Where a room contains a solid-fuel-burning appliance, a CO alarm conforming to CAN/CSA-6.19, Residential Carbon Monoxide Alarming Devices, shall be mechanically fixed a) at a height recommended by the manufacturer s instructions where those instructions specifically mention solid-fuel-burning appliances, or b) in the absence of specific instructions related to solid-fuel-burning appliances, on or near the ceiling. 4) Where a fuel-burning appliance is installed in a suite of residential occupancy, a CO alarm shall be installed a) inside each bedroom, or b) outside each bedroom, within 5 m of each bedroom door, measured following corridors and doorways. 5) Where a fuel-burning appliance is installed in a service room that is not in a suite of residential occupancy, a CO alarm shall be installed a) in the service room, and b) for every suite of residential occupancy that shares a wall or floor/ceiling assembly with that service room, either i) inside each bedroom, or ii) outside each bedroom, within 5 m of each bedroom door, measured following corridors and doorways. 6) For each suite of residential occupancy that shares a wall or floor/ceiling assembly with a storage garage or that is adjacent to an attic or crawl space to which the storage garage is also adjacent, a CO alarm shall be installed a) inside each bedroom, or b) outside each bedroom, within 5 m of each bedroom door, measured following corridors and doorways Handrails Required Handrails 1) Except as provided in Sentences (2) to (4), handrails shall be installed on stairs and ramps in accordance with Table Table Number of Sides of Stair or Ramp Required to Have a Handrail Forming part of Sentence (1) Handrails Serving Stairs Handrails Serving Ramps Stairs < Location of Stair Stairs Ramps < Ramps or Ramp Straight or Straight Curved All Curved All Number of Sides Required to Have a Handrail Within a dwelling unit All other locations (1) ) Where a stair or a ramp is required to be at least mm wide due to the occupant load, a handrail shall be installed such that no position on the stair or ramp is more than 825 mm from a handrail. 3) Handrails are not required for stairs and ramps serving a single dwelling unit, wherea) interior stairs have not more than 2 risers, b) exterior stairs have not more than 3 risers, or c) ramps rise not more than 400 mm. 4) Only one handrail is required on exterior stairs having more than 3 risers provided such stairs serve not more than one dwelling unit Height of Handrails 1) The height of handrails on stairs and ramps shall be measured vertically from the top of the handrail to a) a straight line drawn tangent to the tread nosings of the stair served by the handrail, or b) the surface of the ramp, floor or landing served by the handrail. 2) Except as provided in Sentences (3) and (4), the height of handrails on stairs and ramps shall be a) not less than 865 mm, and b) not more than 965 mm. 3) Where guards are required, handrails required on landings shall be not more than mm in height.
6 4) Handrails installed in addition to required handrails need not comply with Sentence (2) Guards Required Guards 1) Except as provided in Sentences (2) and (3), every surface to which access is provided for other than maintenance purposes, including but not limited to flights of steps and ramps, exterior landings, porches, balconies, mezzanines, galleries and raised walkways, shall be protected by a guard on each side that is not protected by a wall for the length where a) there is a difference in elevation of more than 600 mm between the walking surface and the adjacent surface, or b) the adjacent surface within 1.2 m of the walking surface has a slope of more than 1 in 2. 3) Where an interior stair has more than 2 risers or an interior ramp rises more than 400 mm, the sides of the stair or ramp and the landing or floor level around the stairwell or ramp shall be protected by a guard on each side that is not protected by a wall. 4) Doors in buildings of residential occupancy, where the finished floor on one side of the door is more than 600 mm above the floor or other constructed surface or ground level on the other side of the door, shall be protected by a) a guard, or b) a mechanism capable of controlling the free swinging or sliding of the door so as to limit any clear unobstructed opening to not more than 100 mm. 5) Except as provided in Sentence (6), openable windows in buildings of residential occupancy shall be protected by a) a guard, or b) a mechanism capable of controlling the free swinging or sliding of the openable part of the window so as to limit any clear unobstructed opening to not more than 100 mm measured either vertically or horizontally where the other dimension is greater than 380 mm Height of Guards 1) Except as provided in Sentences (2) to (4), all guards shall be not less than mm high. 2) All guards within dwelling units shall be not less than 900 mm high. 3) Exterior guards serving not more than one dwelling unit shall be not less than 900 mm high where the walking surface served by the guard is not more than mm above the finished ground level. 4) Guards for flights of steps, except in required exit stairs, shall be not less than 900 mm high. 5) The height of guards for flights of steps shall be measured vertically from the top of the guard to a line drawn through the leading edge of the treads served by the guard Openings in Guards 1) Except as provided in Sentence (2), openings through any guard that is required by Article shall be of a size that will prevent the passage of a spherical object having a diameter of 100 mm unless it can be shown that the location and size of openings that exceed this limit do not represent a hazard. (See A (1) and (2) in Appendix A.) Design of Guards to Not Facilitate Climbing 1) Guards required by Article , except those in industrial occupancies and where it can be shown that the location and size of openings do not present a hazard, shall be designed so that no member, attachment or opening facilitates climbing. 2) Guards shall be deemed to comply with Sentence (1) where all elements protruding from the vertical and located within the area between 140 mm and 900 mm above the floor or walking surface protected by the guard conform to at least one of the following Clauses: a) they are located more than 450 mm horizontally and vertically from each other, b) they provide not more than 15 mm horizontal offset, c) they do not provide a toe-space more than 45 mm horizontally and 20 mm vertically, or d) they present more than a 2-in-1 slope on the offset. Please contact the City of Penticton Building department for further information.
Number of Sides Required to Have a Handrail
Excerpt from 2012 B.C. Building Code HANDRAILS & GUARDS 9.8.7. Handrails 9.8.7.1. Required Handrails 1) Except as provided in Sentences (2) to (4), handrails shall be installed on stairs and ramps in accordance
More information9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.
Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and
More informationCITY OF TORONTO. BY-LAW No. 349-2008
Authority: Licensing and Standards Committee Item 12.3, adopted as amended, by City of Toronto Council on April 28 and 29, 2008 Enacted by Council: April 29, 2008 CITY OF TORONTO BY-LAW No. 349-2008 To
More informationBasement Development Construction requirements for the development of basements in residential dwellings.
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Basement Development Construction requirements for the development of basements in residential dwellings. June 2009 contents GENERAL INFORMATION 3 BUILDING
More informationBUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
More informationThe replacement or modification of existing windows shall comply with the following requirements:
City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)
More informationAdult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION
More informationFlorida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS 1009.1 Stairway width. The width of stairways shall be determined as specified in Section 1005.1, but such width shall not be less than 44
More informationShort Term Accommodation Licence Application Guide
Short Term Accommodation Licence Application Guide This guide has been developed for convenience purposes only. The Owner is responsible for ensuring compliance with all Town by-laws and other applicable
More informationMinimum Housing and Health Standards
APPENDIX M.O. 57/2012 Minimum Housing and Health Standards Original version July 20, 1999. Revisions to Part lll, Housing Premises, sections 3 and 4, June 30, 2012 (all revisions are bolded and underlined).
More informationhttp://www.iccsafe.org/
Sections R311 and R312 from the 2006 International Residential Code These sections of Chapter 3 of the 2006 International Residential Code for One and Two Family Dwellings (R311 and R312) including the
More informationCOMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 STAIRWAYS 46. LANDINGS. Section R311 IRC 2009 R311.7.5 Landings for stairways. There shall be a floor or
More informationNew Ontario Building Code Highlights
New Ontario Building Code Highlights Part 9 This summary highlights items that are believed to be significant changes to the 2012 OBC and is not intended to include all changes made within this or other
More informationBOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE
More informationFIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS
CHAPTER 46 FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS SECTION 4601 GENERAL 4601.1 Scope. The provisions of this chapter shall apply to existing buildings constructed prior to a state building
More informationThe Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE
The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE BUILDING SERVICES DEPARTMENT 789 Broadway Street, Box 3000 Wyoming, ON N0N 1T0 Telephone: 519 845-0801 Toll-free: 1-866-324-6912 Fax: 519
More informationSmoke Detector/Carbon Monoxide Detector Inspections
MIDDLESEX COUNTY FIRE MARSHAL 1001 Fire Academy Drive Sayreville, NJ 08872 732-316-7171 (office) 732-316-7638 (fax) To: All Real Estate Agencies/Home Owners Subject: Smoke Detector/Carbon Monoxide Detector
More informationWINDOW AND DOOR REPLACEMENT REQUIREMENTS
WINDOW AND DOOR REPLACEMENT REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern.
More informationProperty Maintenance Check List
Property Maintenance Check List Scope These minimum conditions and responsibilities of persons for maintenance of structures, equipment and exterior property shall govern. Responsibility. Owners shall
More informationMINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY
MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division 444 Cedar Street, Suite 145, St. Paul, Minnesota 55101-5145 Phone: 651/201-7200 FAX: 651/215-0525 TTY: 651/282/6555 Internet: http://www.fire.state.mn.us
More informationCertification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
More informationNew York City Department of Buildings
The New NYC Building Code Chapter 10 Means of Egress New York City Department of Buildings Technical Affairs Fatma M. Amer, P.E. Copyright Materials This presentation is protected by US and International
More informationBuilding Codes Update: The 2009 International Fire Code and the Apartment Industry
! Building Codes Update: The 2009 International Fire Code and the Apartment Industry Apartment operators and developers should be aware of organizational changes in the 2009 edition of the International
More informationBuilding Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
More informationMAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015 **Disclaimer: This document is to serve as informational purposes only. This is not a code book or a final interpretation of the
More informationBUILDING A FENCE? THE CITY OF CAMBRIDGE REQUIRES THAT ALL FENCES WITHIN THE CITY CONFORM TO THE REGULATIONS OF FENCE BY-LAW
BUILDING A FENCE? THE CITY OF CAMBRIDGE REQUIRES THAT ALL FENCES WITHIN THE CITY CONFORM TO THE REGULATIONS OF FENCE BY-LAW FENCING FOR SWIMMING POOLS/HOT TUBS SPECIAL INFORMATION Your attention is drawn
More informationBUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS
DCD-0304 Identification # Rev. 9/08 County Date of Inspection NAME OF OPERATION BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS ADDRESS TELEPHONE: CITY STATE ZIP BUILDING INSPECTORS CERTIFICATE
More informationMINIMUM STANDARDS FOR HIGH-RISE BUILDINGS
CHAPTER 93 MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS Note: Chapter 93 is entirely Seattle amendments to the International Fire Code and is not underlined. Point of Information The requirements of this
More informationArea of Rescue Assistance Communication System ADA Code Applicable excerpts:
Area of Rescue Assistance Communication System ADA Code Applicable excerpts: CONTENTS (Guidelines and Definitions) Page 1 Area of Rescue Assistance Requirements Page 2 Emergency Communication Equipment
More informationRHODE ISLAND DIVISION OF STATE FIRE MARSHAL
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL Smoke Alarm and Carbon Monoxide Brochure JOHN E. CHARTIER STATE FIRE MARSHAL 118 PARADE STREET PROVIDENCE, RI 02909 DAYS 401-462-4200 24 Hr. 401-222-2331 FAX#
More information2007 ICC FINAL ACTION AGENDA
907.2.1.1 System initiation in Group A occupancies with an occupant load of 1,000 or more. Activation of the fire alarm in Group A occupancies with an occupant load of 1,000 or more shall initiate a signal
More informationNC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02
NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02 PART A: Project Data and Classification 1. Project name & location Renovation of the Cheerwine Building, 322 East Council St.,
More informationH:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh
Accessory Apartment Construction Guide For Single Detached Dwelling and Semi-Detached Dwellings that have been in existence for at least five (5) years Notes: Buildings that are less than five (5) years
More informationEAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST
DATE TIME EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST INSPECTOR: LICENSE # ADDRESS: PROPERTY OWNER: SINGLE: DOUBLE: MULTI-UNIT # OF UNITS POINT OF INSPECTION Sanitation IPMC 302.1
More informationPreparation for 2015 Residential Code Changes Discussion with Local Builders and Designers
City of Duluth Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers Thank you for taking the time to join us today. We know you are busy and your time is valuable.
More informationKITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the
More informationNew Ontario Building Code Requirements for Mid-rise Wood Frame Buildings
New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings Note: This information addresses complex issues in a summary fashion. Consideration should be given to the official version of the
More informationExtracts from BUILDING REGULATIONS
Page 1 of 3 UNotes on Building Regulations Please note that British building regulations are complex and that they may vary from area to area. It is your responsibility to ensure that your chosen stair
More informationMUNICIPALITY OF KAZABAZUA. SMOKE DETECTORS By-Law number 07-2012
MUNICIPALITY OF KAZABAZUA SMOKE DETECTORS By-Law number 07-2012 Notice of motion : August 7, 2012 Publication : September 9, 2012 Adoption : November 15, 2012 Effective November 15, 2012 Resolution: 2012-09-234
More informationCITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.
More informationCONSTRUCTION FIRE SAFETY PLANNING GUIDELINES
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.
More informationHow To Build A Basement House
Single Family Basement Finish Purpose of Guide The purpose of this guide is to assist you in the permit process for your project. This handout is intended as a basic plan submittal under the 2009 International
More informationWe hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.
September 14, 2012 Dear AMM Member: Please see the attached Fire Code Frequently Asked Questions. This document was compiled by the Office of the Fire Commissioner at the AMM s request to help clarify
More information527 CMR: BOARD OF FIRE PREVENTION REGULATIONS
527 CMR 31.00: CARBON MONOXIDE ALARMS Section 31.01: Purpose and Scope 31.02: Definitions 31.03: General Installation Provisions 31.04: Specific Installation Provisions 31.05: Carbon Monoxide Protection:
More informationDennis Fire Department Fire Prevention Mark Dellner Fire Chief
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief FIRE SAFETY INSPECTION GUIDELINES FOR COMMERCIAL PROPERTIES (MA Fire Prevention Regulations 527 CMR, MGL Chapter 148) FIRE PREVENTION CHECKLIST-
More informationA Residential Owner s Guide to PERMITS. Elgin CITY OF PLANNING & NEIGHBORHOOD SERVICES
A Residential Owner s Guide to PERMITS CITY OF Elgin PLANNING & NEIGHBORHOOD SERVICES CITY OF Elgin A Residential Owner s Guide Welcome! This booklet has been prepared to provide residential property owners
More informationOntario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12)
Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12) Notice: This e-learning module is intended for general information purposes only. It only highlights certain provisions of the
More informationSingle Family Residential Basement Finish
How to Use This Guide Building Guide Pottawattamie County Planning & Development Department Building & Safety Division Single Family Residential Basement Finish Provide two (2) sets of plans and complete
More informationI N T E R N A T I O N A L R E S I D E N T I A L CO D E
Visual Interpretation Of The I N T E R N A T I O N A L R E S I D E N T I A L CO D E 2006 STAIR BUILDING CODE Portions of this document reproduce sections from the 2006 International Residential Code, International
More informationBuilding Department John Fiedler Construction Official Ext. 211. SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev 4-3-2014
TOWNSHIP OF HILLSBOROUGH COUNTY OF SOMERSET Hillsborough Township Municipal Complex The Peter J. Biondi Building 379 South Branch Road Hillsborough, NJ 08844 P: (908) 369-4313 F: (908) 369-3954 Building
More informationApproved Document M: Part M Access to and use of buildings Volume 1 dwellings. Consultation draft. August 2014
Approved Document M: Part M Access to and use of buildings Volume 1 dwellings Consultation draft August 2014 i Main changes in the 2014 edition This approved document supports Requirements M4(1), M4(2)
More informationRichmond Terrace Condominium Association Rules and Regulations
Richmond Terrace Condominium Association Rules and Regulations September 1st 2014 The following Rules and Regulations are adopted on behalf of Richmond Terrace Condominium for the purpose of assuring that
More informationHOMEOWNER S PERMIT GUIDE
HOMEOWNER S PERMIT GUIDE WHEN IS A PERMIT REQUIRED? Department of Development and Permits 306 Cedar Road, City Hall 2 nd Floor P.O. Box 15225 Chesapeake, VA 23328 Phone: (757) 382-6018 Fax: (757) 382-8448
More informationBuilding Permit, Fire Inspection and Operating Permit Fee Schedule
Chenango County Code Enforcement Building Permit, Fire Inspection and Operating Permit Fee Schedule Building Permit Exceptions: Buildings being used solely for the purpose of agriculture. As per Agricultural,
More informationBY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS
CITY OF MONTRÉAL BY-LAW 03-096 BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS As the municipal administration seeks to ensure that all Montrealers benefit from acceptable housing conditions;
More informationErrata has been identified as follows:
2009 IFC Performing Commercial Fire Inspections Inventory Number: 1424S09 Second Printing; July 2014 Changes HAVE been made- Third Printing: September 2014 Errata has been identified as follows: 1. Page
More informationSUBCHAPTER F. SMOKE ALARMS AND FIRE EXTINGUISHERS
SUBCHAPTER F. SMOKE ALARMS AND FIRE EXTINGUISHERS Sec. 92.251. DEFINITIONS. In this subchapter: (1) "Bedroom" means a room designed with the intent that it be used for sleeping purposes. (2) "Dwelling
More informationDoes Wall Township require an inspection by the building department on resale of a home?
Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,
More informationWinnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
More informationRESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
More informationNoise Control Bylaw No. 4404, 2005. Consolidated for Convenience Only
District of West Vancouver Noise Control Bylaw No. 4404, 2005 Effective Date May 09, 2005 Consolidated for Convenience Only This is a consolidation of the bylaws below. The amendment bylaws have been combined
More informationNFPA 101 2012 SELECT SIGNIFICANT CHANGES
NFPA 101 2012 SELECT SIGNIFICANT CHANGES William E. Koffel, P.E., FSFPE President Koffel Associates, Inc. www.koffel.com wkoffel@koffel.com Expertly Engineering Safety From Fire INTRODUCTION NFPA 101 is
More informationFIRE-FIGHTING DESIGN BRIEF REPORT
P a g e 1 SECTION 04 (Doc.No.A/DBR 001) FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 2 1.0 SCOPE 2.0 STANDARDS AND CODES 3.0 TYPES OF SYSTEM PROPOSED 4.0 FIRE HYDRANT SYSTEM 5.0 AUTOMATIC SPRINKLER SYSTEM
More informationFire Alarm Systems Requirements by Occupancy Type
WALT WHITE Fire Chief 5770 Freeport Blvd., Suite 200 Sacramento, CA 95822-3516 Ph: (916) 808-1300 Fax: (916) 808-1629 www.sacfire.org Fire Alarm Systems Requirements by Occupancy Type 2013 California Building
More informationBUILDING MOVE PROCESS INSIDE CITY LIMITS
To move a building from outside or within the City to a site within City limits, the following STEPS must be taken before the move can take place: 1. A written request to relocate a dwelling must be provided
More informationPERMITS REQUIRED & PERMIT EXEMPTIONS
PERMITS REQUIRED & PERMIT EXEMPTIONS This guideline is intended to assist the applicant in determining what types of construction work require a permit. The 1997 California Uniform Administrative Code,
More informationHousing Quality Standards Inspection Checklist
Housing Quality Standards Inspection Checklist To prevent delays, the R.T.A. must be complete and upon submission the unit must be in move in condition or an inspection will not be conducted. A Fair Housing
More informationMINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY
MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division 444 Cedar Street, Suite 145, St. Paul, Minnesota 55101-5145 Phone: 651/201-7200 FAX: 651/215-0525 TTY: 651/282/6555 Internet: http://www.fire.state.mn.us
More informationGas Meter Clearances and Service Installation Requirements
March 2016 Gas Meter Clearances and Service Installation Requirements Builder/Owner/Developer Requirements Call PSE's Customer Construction Services 1 888 321 7779 or visit PSE.com/CustomerConstruction
More informationDesign Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013
Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems April 2013 The National Multi Housing Council and the National Apartment Association (NMHC/NAA) have
More informationOverview of Hotel Fire Safety Requirements
Overview of Hotel Fire Safety Requirements in the Fire Code Susan Clarke, P.Eng. Office of the Fire Marshal - January 10, 2012 1 Agenda Regulation History - Hotels Fire Code Overview (Parts 1 to 8) Defined
More informationNew York City Department of Buildings
The New NYC Building Code Chapter 11 Accessibility New York City Department of Buildings Technical Affairs Keith Wen, R.A. Copyright Materials This presentation is protected by US and International Copyright
More informationMinistry of the Environment Decree. on housing design
G1 THE NATIONAL BUILDING CODE OF FINLAND Housing Design Regulations and Guidelines 2005 Ministry of the Environment Decree on housing design adopted in Helsinki on the 1 st of October 2004 In accordance
More informationName Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
More informationBuilding Permits: When are they required?
Building Permits: When are they required? Generally, you need to obtain a building permit from the City whenever you construct, enlarge, alter, repair, move, remove, improve, convert, or demolish a building
More informationCh. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT
Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE Sec. 58.1. Division D-O occupancies. 58.2. Separation and mixed occupancy. OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM
More informationCharter Township of Shelby Harry Reese Building Director
Charter Township of Shelby Harry Reese Building Director Phone: (586) 731-5969 52700 Van Dyke Fax: (586) 803-2099 Shelby Township, MI 48316-3572 E-mail: building@shelbytwp.org OUTLINE PROCEDURES FOR PRIVATE
More informationFire Alarm System Plans Submittal Guidelines For New and Existing Systems
Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationU.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!
U.S. Department of Housing and Urban Development Office of Public and Indian Housing A Good Place to Live! Introduction Having a good place to live is important. Through your Public Housing Agency (or
More information2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012
2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,
More informationInstructions for Obtaining a Certificate of Smoke Detector, Carbon Monoxide Alarm, and Kitchen Fire Extinguisher Compliance
Princeton Department of Emergency & Safety Services Instructions for Obtaining a Certificate of, Carbon Monoxide Alarm, and Kitchen Fire Extinguisher Compliance 1. Obtain an application Download from /forms
More informationHow To Install A Carbon Monoxide Detector
NASSAU COUNTY FIRE COMMISSION OFFICE OF THE FIRE MARSHAL Nassau County Public Safety Center 1194 Prospect Avenue Westbury, New York 11590 (516) 573-9900 / nassaucountyny.gov Chief Fire Marshal Scott D.
More informationWalking and Working Surface Checklist:
Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:
More informationArapahoe County Residential Water Heater Installation and Inspection Guide
Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however
More informationCommon ADA Errors and Omissions in New Construction and Alterations
U.S. Department of Justice Civil Rights Division Disability Rights Section Common ADA Errors and Omissions in New Construction and Alterations Introduction The ADA requires that new construction and alterations
More informationA HOMEOWNERS GUIDE TO BUILDING IN GREY HIGHLANDS
A HOMEOWNERS GUIDE TO BUILDING IN GREY HIGHLANDS AIM AND APPLICATION OF THE GUIDE This guide is intended to help you better understand the requirements for building as set by applicable law, which could
More informationBuilding Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County
Building Permit Application Packet The purpose of Building Codes is to establish the minimum requirements to safe guard the public health, safety and general welfare through structural strength, means
More informationGROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264
BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used
More informationA Guide to Building Permits for Home Owners / Renovators. Address: 1 Carden Street Guelph, Ontario N1H 3A1
A Guide to Building Permits for Home Owners / Renovators Address: 1 Carden Street Guelph, Ontario N1H 3A1 Oct 2009 Telephone: 519-837-5615 Committee of Adjustment 519-837-5615 option #5 email: cofa@guelph.ca
More informationCity of Peterborough
City of Peterborough Building Division Basement Finishing Guide Residential Information Guides This information is intended to be used as an guide that outlines minimum requirements when finishing a basement,
More informationGeneral Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission Local Fire Alarm 064. FIRE ALARM SYSTEMS 01. Scope 02. Definitions 03.
More informationCity of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov
City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov BUILDING CODE REQUIREMENTS FOR CHILD DAY CARE The purpose of this document is to provide the user with a basic level
More informationDevelopment Variance Permit Application Package
When do I need a Development Variance Permit? Development Variance Permit Application Package If my proposed development does not meet the standards set out in the Zoning Regulation Bylaw on matters that
More informationALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS
ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for
More informationPage 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.
Page 1 of 17 Page 2 of 17 Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology. CODE PARAGRAPH WITH SUGGESTED CHANGES: 6.4.6.1.2 Residents should be rated as response probable
More informationNRC Canadian Codes Centre. Codes Update. Nedjma Belrechid October 2012
NRC Canadian Codes Centre Codes Update Nedjma Belrechid October 2012 Codes Update Outline Activities of CCBFC, PTPACC, NRC-IRC Code Development Public Reviews Active/Inactive SC Tasks Detailed: Step Dimensions
More informationINSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1
City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included
More informationResidential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks
More informationSchedule B to By-law 33-2009 Part A Fees Payable for Permits
Floor Area Calculation Floor area shall: Part A Fees Payable for Permits (Effective January 1, 2015) a) be calculated by measuring to the outer face of exterior walls and to the centre of party walls or