TOPATEC GmbH has been manufacturing their own design of waste water systems since 1999.

Size: px
Start display at page:

Download "TOPATEC GmbH has been manufacturing their own design of waste water systems since 1999."

Transcription

1 PLUMBING

2 TOPATEC GmbH has been manufacturing their own design of waste water systems since Important processes and products designed by TOPATEC are under legal protection. TOPATEC with its constantly renewed and improved, innovative products, provides smart solutions to its customers for their success. Years of experience in the field, innovative know-how and first class q. uality, makes TOPATEC A reliable partner in oil separator solutions. TOPATEC certified suppliers and partners provide a high quality standard, a wide range of products and product oriented services. This enables to offer suitable products for almost any applications. CERTIFICATIONS The Total Quality Management System implemented by TOPATEC GmbH is sufficient to meet the requirements of numerous European countries as well as national requirements.

3 GREASE SEPARATORS Underground Installation Made of PE-HD Aboveground Installation Made of PE-HD

4 FH (above ground) and FE (under ground) type TOPATEC LIPOMASTER with integrated sediment holder, compliant with DIN EN , DIN EN and DIN standards TOPATEC PE grease separator, separates grease from water with maximum efficiency and safety. TOPATEC separators stand out with their high quality, long useful life and reliability. The use of grease separators is subject to DIN EN and DIN EN standards along with DIN international standards. Applications: In kitchen systems and larger kitchens (Restaurants, hotels, cafes and etc.) Grill and fryer kitchens Companies hosting dinners Butchers (slaughter houses and others) Slaughter houses Companies with intestine processing facilities Companies producing cooking oils Canned food manufacturing facilities Fish processing plants Animal feed manufacturers Soap and etc. manufacturers Other applications Advantages: Operate on safety is certified by DIBt Berlin. Compliant to the newest DIN and DIN EN standards. Rugged and dimensional stability - static tests performed by LGA Nurnberg and certified by DIBt Berlin. Resistant to corrosion thanks to PE HD material used. Resistant to fire. Burning behavior was tested and certified by the Research Institute. Rugged thanks to its monolithic structure. The structure is reinforced (for integration flexibility) Light weight of the product allows for easier installation. Provides non-bounding project solutions (scalability)

5 TOPATEC LIPOMASTER-FE Under Ground FE TOPATEC LIPOMASTER FE separators with adjustable height telescopic shaft made of PE-HD to be installed below ground. With general DIBT license Z DIN EN 1825 and DIN compliant With integrated sludge trap, hood made of PE-HD, variable height and level adjustment, load class A/B EN 124 compliant (pedestrian & bicyclists / parking lots ), with odor proof cover OPTIONAL ACCESSORIES PE-HD sample check tank level alarm A, B, D class shaft covers 75 direct disposal line with DIN flange 100 direct disposal line with DIN flange 500mm long extension shaft Ø770 Ø648 /Da /Da T min-max for A,P,B classes T min-max for D class : mm : mm Sludge Trap Separator Storage H Da A B Product Code By Cover Load Classes A Height Not Adjustable P 600 kg Height Adjustable B 12.5Tons Height Adjustable D 40 Tons Height Adjustable A P B D A P B D A P B D 5, A P B D

6 TOPATEC LIPOMASTER-FH STANDARD Above Ground Standard TOPATECLIPOMASTER-FTANDARD Base model for TOPATEC Separator segment for above ground installation. Direct disposal connection TOPATECLIPOMASTER-Ftandard Ready for connection grease separation system for free standing installations in frost protected areas. Fast and easy installation Integrated sludge trap compliant to DIN 4040 / DIN EN 1825 standards Odour proof screwed cover Modular structure (NG 8,12,16) Direct disposal connection (1) The body is made of PE-HD (2) Inlet height, 100 (ᴓD 110 mm) (3) Sludge trap chamber, Height (4) Discharging outlet (5) Screwed cover made of PE-HD (Gasket EPDM) (6) Outlet height, 100 (ᴓD 110 mm) (7) separation chamber (8) Sight glass, stainless steel / glass material (9) : Maximum operating water level Inlet and outlet 100 Made of PE-HD for DIN compliant connection pipes, made of PP or HT material for DIN compliant connection pipes, made of SML for DIN compliant connection pipes. Sludge Trap Separator Storage H H3 Ø D AxB L F Product Number * *

7 NGG88,1,122,1,616 Inlet Inlet Outlet Sludge Trap Separator Storage H3 Ø D AxB L F Product Number *403 2*351 2* * *403 3*351 3* * *403 4*351 4* * Ürün No. Adı NS 1 ilâ 4 için 100 numune alma kabı NS 8 için 150 numune alma kabı NS 12 için 200 numune alma kabı NS 16 için 250 numune alma kabı Temiz su besleme musluğu Gözetlemecamı Yağ tabakası kalınlık ölçümü

8 TOPATEC LIPOMASTER-FH-AS1 Above Ground With Manual Mixing & Shredding System TOPATEC LIPOMASTER-FH-AS1 LIPOMASTER-FH-AS1 allows for complete removal of grease products with mixing - grinding method and simultaneous tank internal washing feature TOPATEC LIPOMASTER-FH-AS1 separation system with pre-assembled components for freestanding installations in frost protected areas. Manual mixing - shredding system Internal tank cleaning system Easy installation thanks to pre-mounted system components Integrated sludge trap compliant to DIN 4040 / DIN EN 1825 standards Odour proof screwed cover Modular structure (NG 8,12,16) Direct disposal connection Odour free cleaning is possible due to the closed system design. Manually started mixing - shredding processes homogenize the separator content, provide an easier and safer way for getting rid of the grease and extends the useable life of your grease separator. (1) The body is made of PE-HD (2) Inlet height, 100 (ᴓD 110 mm) (3) Sludge trap chamber, Height (4) Discharging outlet (5) Screwed cover made of PE-HD (Gasket EPDM) (6) Outlet height, 100 (ᴓD 110 mm) (7) separation chamber (8) Sight glass, stainless steel / glass material (9) : Maximum operating water level Inlet and outlet 100 Made of PE-HD for DIN compliant connection pipes, made of PP or HT material for DIN compliant connection pipes, made of SML for DIN compliant connection pipes Sludge Trap Separators capacity Storage H3 Ø D AxB L F Product Number * *

9 NNG 8,122,,1166 Inlet Inlet outlet Outlet Sludge Trap Separators Storage H3 Ø D AxB L F Product Number *403 2*351 2* * *403 3*351 3* * *403 4*351 4* * Ürün No. Adı NS 1 ilâ 4 için 100 numune alma kabı NS 8 için 150 numune alma kabı NS 12 için 200 numune alma kabı NS 16 için 250 numune alma kabı Temiz su besleme musluğu Gözetlemecamı Yağ tabakası kalınlık ölçümü

10 TOPATEC LIPOMASTER-FH-AS2 Above Ground With Manual Mixing- Shredding and Disposal System TOPATEC LIPOMASTER-FH-AS2 LIPOMASTER-FH AS2 allows for complete removal of grease products with mixing, shredding method and simultaneous tank internal washing feature. Following the rinsing and mixing process, homogenized grease separator content is pumped into a sewage truck over the mixing - shredding pump manually. TOPATECLIPOMASTER-FH-AS 2 Direct grease remote control separation system with pre-assembled components for freestanding installations in frost protected areas. Manual mixing - shredding system Internal tank cleaning system Pumping of grease separator content via manual control into a sewage truck over the mixing - shredding pump. Easy installation thanks to pre-mounted system components Integrated sludge trap compliant to DIN 4040 / DIN EN 1825 standards Odour proof screwed cover Modular structure (NG 8,12,16) Odour free cleaning is possible due to the closed system design. Manually started mixing - shredding and discharging processes homogenize the separator content, provide an easier and safer way for getting rid of the grease and extends the useable life of your grease separator. (1) The body is made of PE-HD (2) Inlet height, 100 (ᴓD 110 mm) (3) Sludge trap chamber, Height (4) Discharging outlet (5) Screwed cover made of PE-HD (Gasket EPDM) (6) Outlet height, 100 (ᴓD 110 mm) (7) separation chamber (8) Sight glass, stainless steel / glass material (9) : Maximum operating water level Inlet and outlet 100 Made of PE-HD for DIN compliant connection pipes, made of PP or HT material for DIN compliant connection pipes, made of SML for DIN compliant connection pipes Sludge Trap Separators Storage H3 Ø D AxB L F Product Number * *

11 NG 88,,1122,1,166 Inlet Inlet Outlet Outlet Sludge Trap Separator Storage H3 Ø D AxB L F Product Number *403 2*351 2* * *403 3*351 3* * *403 3*351 4* * Ürün No. Adı NS 1 ilâ 4 için 100 numune alma kabı NS 8 için 150 numune alma kabı NS 12 için 200 numune alma kabı NS 16 için 250 numune alma kabı Temiz su besleme musluğu Gözetlemecamı Yağ tabakası kalınlık ölçümü

12 TOPATEC LIPOMASTER-FH-AS3 Above Ground With Automatic Mixing, Shredding and Discharge System TOPATEC LIPOMASTER-FH-AS3 Allows complete removal of grease products with automatic mixing, shredding method and simultaneous tank internal washing feature. Following the rinsing and mixing process, homogenized grease separator content is pumped into a sewage truck. After the content is discharged (using fresh water or alternatively, rain water) grease separator is fully automatically re-filled TOPATECLIPOMASTER-FH-AS3 Remote controlled, fully automated, direct grease removal. separation system with pre-assembled components for freestanding installations in frost protected areas. Automated mixing - shredding system Internal tank cleaning system. Pumping of grease separator content automatically into a sewage truck over the mixing - grinding pump. Discharging with remote control Automated refilling after discharge Integrated sludge trap compliant to DIN 4040 / DIN EN 1825 standards Odour proof screwed cover Modular structure (NG 8,12,16) Odour free cleaning is possible due to the closed system design. Automatically started mixing - shredding and discharging processes homogenize the separator content, provide an easier and safer way for getting rid of the grease and extends the useable life of your grease separator. (1) The body is made of PE-HD (2) Inlet height, 100 (ᴓD 110 mm) (3) Sludge trap chamber, Height (4) Discharging outlet (5) Screwed cover made of PE-HD (Gasket EPDM) (6) Outlet height, 100 (ᴓD 110 mm) (7) separation chamber (8) Sight glass, stainless steel / glass material (9) : Maximum operating water level Inlet and outlet 100 Made of PE-HD for DIN compliant connection pipes, made of PP or HT material for DIN compliant connection pipes, made of SML for DIN compliant connection pipes Sludge Trap Separator Storage H3 Ø D AxB L F Product Number * *

13 NGN8G,182,162,16 Inlet Inlet Outlet Outlet Sludge Trap Separator Storage H3 Ø D AxB L F Product Number *403 2*351 2* * *403 3*351 3* * *403 3*351 4* * Ürün No. Adı NS 1 ilâ 4 için 100 numune alma kabı NS 8 için 150 numune alma kabı NS 12 için 200 numune alma kabı NS 16 için 250 numune alma kabı Temiz su besleme musluğu Gözetlemecamı Yağ tabakası kalınlık ölçümü

14 TOPATEC OIL SEPARATORS Made of PE-HD, DIN 1999, part 4-6 and DIN EN class I or class I and II compliant A significant slackness is achieved in light fluid - waste water mixture flowing inside the DIN 1999 petroleum separator by increased flow cross section and enlarged top surface. A separation is achieved using only gravitational effect, which means that especially light weight particles (such as carbonated water, gasoline, oil, etc.) bubble up and form a floating layer on the surface. The connection part on the flow side activates automatically, following the line separating the oil and water and upon reaching maximum filling level, closes the drainage opening Warning: NS 6 and NS 10 include 2 reservoirs. Cover classes that are resistant to weight of cars passing over them are available for P24 and B 125. Tmin Available with D 400 class load distribution plate. H 455l 660 Liter Schlammfang Di Product Code by Cover Load Classes (1/s) Sludge Trap (I) Internal Diameter (I) H Maximum Weight (kg) B D B D B D

15 System Components And Functions TOPATEC TOP 01/08/18/011 type visual - audible alarm system ṪOPATEC TOP 18 is an automatic alarm system for light weight fluid separators (oil and compound separator) that is licensed for use in zone 0 areas with explosion hazard. It is used for measuring the highest level (oil thickness and surge) of a fluid in the separator. Compound attachment must be used as overflow safety and for sublimation compensation in accordance with DIN , Clause 5.7. O O th t e h r e a r la l r a m rm sy s s y t s e t m em s: s: TOP 01 for oil level detection T O TO P P fo f r o h r a o n il d le lin v g el s d a e fe te ty ction TOTOPP01018 ffoorr ohial nledvleinlgdestaefcetiyon TOP 011 for oil level detection TOPATEC Wall penetration system The wall penetration system is a cable sleeve system that is resistant to oil, gas and water with a standard 50 ( 100 optionally) diameter with three configuration options. The wall penetration systems are made of high quality steel / NBR. The system is also used to isolate the penetration of the cables inside concrete walls. TOPATEC test kit for separator systems in accordance with DIN TOPATEC test kit provides you with the complete set of tools that allow you to perform your own checks Extendable channel hook Sludge level measurement device level measurement device Flashlight ph value measurement paper Operating log Cleaning brush

16 ALTAYMEKANİK ISI SİSTEMLERİ İNŞ. TUR. İÇ ve DIŞ. TİC. LTD. ŞTİ. tescilli markasıdır. Anadolu Bulvarı 2. Cadde A.T. B. İş Merkezi EBlok No: Macunköy-Ankara/TÜRKİYE Tel: +90(312) (pbx) Fax: +90(312)

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance 02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW

More information

National Precast Concrete Association

National Precast Concrete Association National Precast Concrete Association NOTES 1. This manual does not claim or imply that it addresses any safety-related issues associated with its use. Operation and maintenance of precast concrete grease

More information

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public

More information

PROCESS AUTOMATION. ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW

PROCESS AUTOMATION. ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW PROCESS AUTOMATION Protection for the environment ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW warning devices for separator systems Detects dangers to protect the environment Water is the basis of all

More information

Drainage and Grease Management for the Commercial Kitchen

Drainage and Grease Management for the Commercial Kitchen Drainage and Grease Management for the Commercial Kitchen ACO. The future of drainage. The ACO system chain provides drainage solutions to meet the needs of tomorrow s food service facilities. Hostile

More information

Drains and shower channels. Wastewater Drainage

Drains and shower channels. Wastewater Drainage Drains and shower channels Wastewater Drainage Drains for industrial and public buildings Bathrooms Wellness Ecoguss... 75 78 Practicus... 79 81 Bathroom drains For use in the private and commercial sector

More information

Grease Trap Maintenance, Procedures and Cleaning Logs

Grease Trap Maintenance, Procedures and Cleaning Logs SAWS Grease Reduction Program Grease Trap Maintenance, Procedures and Cleaning Logs Don t Feed the Grease Monster Best Management Practices for Commercial Food and Restaurant Facilities Train kitchen staff

More information

Grease disposal concepts. Grease separators. For full and partial disposal For free-standing or ground installation

Grease disposal concepts. Grease separators. For full and partial disposal For free-standing or ground installation Grease separators Grease disposal concepts Grease separators For full and partial disposal For free-standing or ground installation Selecting the correct separator Areas of application Hotels Restaurants

More information

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION Grease, So What's the Problem? Does your facility produce grease? All commercial cooking facilities generate Fats, Oil, and Grease

More information

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Shower and Floor Gullies Channel Drain and Tile Drain SECTION Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions

More information

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812 TABLE OF CONTENTS Pictorial Index Product Recommendations Grease Interceptors Commonly Specified Options Typical Installations Oil Interceptors Commonly Specified Options Typical Installations Sediment

More information

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems PACKAGE SEWAGE TREATMENT SYSTEM Clearwater treatment plants are ideal for single houses and employ the well proven aerobic biological

More information

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. SANITARY & WASTE WATER PUMPING SYSTEMS Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. Wallace Pumps solve all those waste disposal problems, big or small, with

More information

www.steelformcatering.com

www.steelformcatering.com www.steelformcatering.com catering cat e r i n g We are specialized in the production and sub furniture of components for mechanical industry, sector for which we even furnish advice and collaborate in

More information

ACO Building Drainage

ACO Building Drainage Uniclass L21725 CI/SfB (52.9) August 2013 Grease management ACO Building Drainage Product catalogue ACO Gravity Grease Separators ACO Building Drainage ACO Building Drainage Our built environment is becoming

More information

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves

More information

GPD Rubber Press Seals

GPD Rubber Press Seals GPD Rubber Press Seals Leading in in ideas SYSTEM-TECHNIK GPD Rubber Press Seals Design Available with a rubber thickness of 30 mm for sealing against non-pressing water and a rubber thickness of 60 mm

More information

Revised April (May) 2015

Revised April (May) 2015 Section 19.0 Cross Connection Control Policy 19.1 Responsibility 19.1.1 The Elkhart Water Utility has the responsibility to supply safe, potable water from the source to the point of delivery defined as

More information

Domestic Wastewater Treatment Up to 6 Population (6PE)

Domestic Wastewater Treatment Up to 6 Population (6PE) Domestic Wastewater Treatment Up to 6 Population (6PE) www.mjabbott.co.uk Tel: 01722 716361 e-mail: sales@mjabbott.co.uk Fax: 01722 716828 The Solido EN 12566-3 Test Certificate Our system was tested with

More information

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable

More information

NEEP ShallowTray Low Profile Air Strippers

NEEP ShallowTray Low Profile Air Strippers NEEP ShallowTray Low Profile Air Strippers Discreet size designed for smaller spaces, indoors or outdoors Removes a wide variety of volatile organic contaminants Wide variety of sizes and number of trays

More information

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE 31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE Edited 21/12/01 Wyong Shire Council has many non sewered areas that

More information

Grease Traps and Interceptors

Grease Traps and Interceptors Grease Traps and Interceptors Dorchester County Water and Sewer Introduction Fats, oils, and greases (FOG) can build up in sewer pipes, resulting in costly and messy overflows. It is bad for business,

More information

LANDSCAPING AQUA SPORT. Rainwater treatment using filter substrate channel. DIBt approval applied for

LANDSCAPING AQUA SPORT. Rainwater treatment using filter substrate channel. DIBt approval applied for CIVILS LANDSCAPING AQUA SPORT Drainfix Clean Rainwater treatment using filter substrate channel DIBt approval applied for CIVILS LANDSCAPING AQUA SPORT Drainfix Clean Application areas For the treatment

More information

ROBOT PUMPS RT - TURBOTEX PUMPS

ROBOT PUMPS RT - TURBOTEX PUMPS ROBOT PUMPS RT - TURBOTEX PUMPS RT- Turbotex pumps The Robot submersible Turbotex pumps form the ultimate solution in today s pumping technology. The self cleaning blade leading edge effectively deals

More information

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw.

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw. Compact pumps from the wastewater experts FLYGT 304, 307, 3068. Power range 0.7.4 kw. Wastewater is unpredictable, Flygt pumps are not If you want a wastewater pump that just works month after month, year

More information

Best Management Practices

Best Management Practices for The City of Paso Robles is required to implement a Phase II Municipal Water Program in order to reduce or eliminate the pollutants that enter our waterways from both storm water and non-storm water

More information

solarplus solar systems general features

solarplus solar systems general features SOLARPLUS solar systems solarplus Applications: expansion vessels for solar systems Zilmet, an internationally operating company with over 50 years of experience has grown to be the biggest European producer

More information

Guidelines for Precast Concrete Grease Interceptors

Guidelines for Precast Concrete Grease Interceptors Guidelines for Precast Concrete Grease Interceptors Purpose Provide an overview of the basic design principals that govern why gravity grease interceptors work Provide a forum for discussion of common

More information

STATE BANK OF INDIA.

STATE BANK OF INDIA. Page 1 of 5 B SANITARY, PLUMBING & DRAINAGE STATE BANK OF INDIA. PROPOSED RURAL SELF EMPLOYMENT TRAINING INSTITUTE AT RAIGARH IN C.G. DIRECTOR'S BUNGALOW SCHEDULE OF ITEMS-PLUMBING AND SANITARY WORK 1

More information

SIR 900-1100. INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

SIR 900-1100. INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES OPERATING LIMITS Useful volume up to : L 9 L Ambient temperature : to + C Max.fluid temperature : + C* passing blade at : mm Ø Inlet dia. : mm DN Ø Outlet dia. : / Ø Vent dia.: mm Ø Cable passage : mm

More information

Spill Prevention, Control and Countermeasure (SPCC) Rule

Spill Prevention, Control and Countermeasure (SPCC) Rule Spill Prevention, Control and Countermeasure (SPCC) Rule Code of Federal Regulations Title 40 CFR Part 112 Training Guide for Oil and Fuel handlers on Farms 1 Purpose of SPCC Rule To prevent oil discharges

More information

Waste Oil Handling, Spill Containment & Lighting

Waste Oil Handling, Spill Containment & Lighting 58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20

More information

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant. Postbus 9058 6070 AB Swalmen (NL) Akzo Nobel Car Refinishes S.L./Coatings S.L. Att. Mr. Cesar Franch Tel. +31(0)77-7676276 Fax +31(0)77-7676286 e.mail info@ants-tech.nl website www.ants-tech.nl cesar.franch@akzonobel.com

More information

Packaged Sewage Treatment Plants with a Future

Packaged Sewage Treatment Plants with a Future Packaged Sewage Treatment Plants with a Future Market Leader for containers made from PE Top quality SBR-treatment (Sequence Batch Reactor) System for clean water seepage Safeguard for the future with

More information

Plumbing for retail food businesses

Plumbing for retail food businesses Plumbing for retail food businesses Every day, thousands of food outlets in Sydney produce waste, such as cooking oil, grease and food solids. If that waste is discharged directly into our sewers, it can

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass JR12/JR23 L731 CI/SfB (52.7) ACO Q-Ceptor Bypass and full retention oil separators ACO Q-Ceptor Introduction to the ACO Group Throughout the world

More information

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems Homeowners and Home Buyers Guide to Wells and Private Sewage Systems What every homeowner should know about living with a well and a private sewage system. YOUR ENVIRONMENTAL SYSTEMS Out of sight out of

More information

ACO Building Drainage

ACO Building Drainage ACO Building Drainage Backflow systems Backflow systems 33 Stop that backflow ACO backflow stops and lifting plant Contents Background What causes backflow?... 3 Liability aspects... 3 The backflow level...

More information

Drainage Management for the Food & Beverage Industry

Drainage Management for the Food & Beverage Industry Drainage Management for the Food & Beverage Industry ACO. The future of drainage CONTENT ACO system & service chain 02 Today, when food can be produced in any corner of the world and land on your table,

More information

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012 DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY August 2012 SECTION 2 The storage requirements in Directive 055 apply to upstream petroleum facilities, well sites, and pipelines

More information

EUROPLAST S.P.A. 31025 S. LUCIA DI PIAVE - Via Gorizia, 7 - (Tv) - Italy. Tel. +39 0438.4697 - Fax +39 0438.460766. www.europlast.

EUROPLAST S.P.A. 31025 S. LUCIA DI PIAVE - Via Gorizia, 7 - (Tv) - Italy. Tel. +39 0438.4697 - Fax +39 0438.460766. www.europlast. EUROPLAST S.P.A. 31025 S. LUCIA DI PIAVE - Via Gorizia, 7 - (Tv) - Italy Tel. +39 0438.4697 - Fax +39 0438.460766 www.europlast.it e-mail: europlast@europlast.it 09/05 drainage system EXPORT COMPANY PROFILE

More information

HEAVY DUTY SEVERING AND BEVELLING MACHINE TNO FAB-SERIES

HEAVY DUTY SEVERING AND BEVELLING MACHINE TNO FAB-SERIES HEAVY DUTY SEVERING AND BEVELLING MACHINE TNO FAB-SERIES PROTEM USA LLC 29340 Industrial Way, # 402 Evergreen, CO 80439 USA Phone: +1 303 955 4862 Fax: +1 303 955 5904 contact@protemusa.com www.protemusa.com

More information

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only. SEPTIC TANK SYSTEMS There are three common types of septic tank systems in Tasmania Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only. Dual purpose (or all-waste)

More information

DRAINAGE SYSTEMS FOR BEVERAGE INDUSTRIES

DRAINAGE SYSTEMS FOR BEVERAGE INDUSTRIES DRAINAGE SYSTEMS FOR BEVERAGE INDUSTRIES K E E P I N G U P T H E F L O W S T A I N L E S S S T E E L D R A I N A G E S Y S T E M S BREWERIES & DAIRIES BLÜCHER provides drainage solutions for removing

More information

Element D Services Plumbing

Element D Services Plumbing Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.

More information

OIL SPILL CONTAINMENT CONTAINERS AND RACKING

OIL SPILL CONTAINMENT CONTAINERS AND RACKING www.lubecontrol.com.au OIL SPILL CONTAINMENT CONTAINERS AND RACKING Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: info@lubecontrol.com.au

More information

FLUIDO. Fully Biological Sewage Treatment Plant. We clear it for you. according to EN 12566-3. Packaged Sewage Solutions with a Future (4-300 PT)

FLUIDO. Fully Biological Sewage Treatment Plant. We clear it for you. according to EN 12566-3. Packaged Sewage Solutions with a Future (4-300 PT) FLUIDO Fully Biological Sewage Treatment Plant according to EN 12566-3 Packaged Sewage Solutions with a Future (4-300 PT) We clear it for you REWATEC Top Quality from Germany A sewage treatment plant is

More information

E nv i ro n m e nta l. Biotec 5-7. Sustainable, Reliable, Affordable

E nv i ro n m e nta l. Biotec 5-7. Sustainable, Reliable, Affordable E nv i ro n m e nta l Biotec 5-7 Package Sewage Treatment for Residential, Business & Leisure Applications Sustainable, Reliable, Affordable ENTEC BIOTEC 5-7 FROM KINGSPAN ENVIRONMENTAL Package Sewage

More information

Puddle Flange. FRANK Puddle Flange

Puddle Flange. FRANK Puddle Flange Puddle Flange FRANK Puddle Flange The problem Problems keep on occurring when connecting pipes during construction work. Pipes laid in the ground must be introduced into concrete walls or shafts. In many

More information

Septic System Owner s Manual

Septic System Owner s Manual Septic System Owner s Manual Sponsored by: copyright 2013 No part of this publication may be reproduced without our consent. www.callbrownies.com Brownie s Septic and Plumbing has provided quality service

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

ACO ShowerDrain S-line Setting new standards for bathroom drainage

ACO ShowerDrain S-line Setting new standards for bathroom drainage ACO ShowerDrain S-line Setting new standards for bathroom drainage ACO. The future of drainage. The ACO system chain provides the drainage solutions for tomorrow s environmental conditions. Increasingly

More information

The most advanced Undersink Sullage System with inbuilt controls and alarms.

The most advanced Undersink Sullage System with inbuilt controls and alarms. Optional Interlock Panel The most advanced Undersink Sullage System with inbuilt controls and alarms. The Aquatec Sinktec Sullage System is used to handle sink and basin waste in circumstances where gravity

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

HUBER Vacuum Rotation Membrane VRM Bioreactor

HUBER Vacuum Rotation Membrane VRM Bioreactor HUBER Vacuum Rotation Membrane VRM Bioreactor VRM The rotating plate membrane for clean water applications. The future-oriented solution designed for the ever increasing requirements in wastewater treatment

More information

NFPA31FuelOilPiping 1 Revised 3-1-11

NFPA31FuelOilPiping 1 Revised 3-1-11 NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from

More information

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN 858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe

More information

save water, save money, save the environment Monsoon domestic rainwater harvesting systems

save water, save money, save the environment Monsoon domestic rainwater harvesting systems save water, save money, save the environment Monsoon domestic rainwater harvesting systems Welcome to Monsoon by Stormsaver Stormsaver is the UK market leader for low energy, money-saving and environmentally-sensitive

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Grease and Oil Wastes Problems andsolutions A grease trap is a device used for removing oil and grease from wastewaters. Grease traps perform this

Grease and Oil Wastes Problems andsolutions A grease trap is a device used for removing oil and grease from wastewaters. Grease traps perform this Grease and Oil Wastes Problems andsolutions A grease trap is a device used for removing oil and grease from wastewaters. Grease traps perform this function very well, provided they are constructed and

More information

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS GEORGIA DEPARTMENT OF HUMAN RESOURCES ENVIRONMENTAL HEALTH SECTION A HOMEOWNERS GUIDE TO ON-SITE SEWAGE MANAGEMENT SYSTEMS March 12, 2002 WHAT IS AN ON-SITE SEWAGE MANAGEMENT SYSTEM An on-site sewage management

More information

Automatic Back-Flushing Filter AutoFilt RF9.

Automatic Back-Flushing Filter AutoFilt RF9. Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization

More information

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION Oxford Hills Bus Garage 36 Brown St, Norway, ME Oil Storage Inspection 2/20/14 CONDITIONS OBSERVED Underground Oil Storage: 12,000 gallon underground oil storage tank (split 10,000 gallon diesel/2,000

More information

KEG Sewer Cleaning Equipment for Experts

KEG Sewer Cleaning Equipment for Experts KEG Sewer Cleaning Equipment for Experts email: sales@rolba.co.uk Sighted Nozzle small Sewer cleaning and inspection all in one go completely wireless Advantages: cleaning nozzle boasting 8 jets for efficient

More information

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY Draft CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY Draft Los Angeles Plumbing Code (LAPC) 2008 California Plumbing Code (CPC) 2007 Uniform Plumbing Code (UPC) 2006 Major Code Changes Preliminary

More information

KESSEL Oil / Fuel separator KESSEL Coalescence separator

KESSEL Oil / Fuel separator KESSEL Coalescence separator INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Oil / Fuel separator KESSEL Coalescence separator PE Separators according to Euro-norm EN 858 NS 3-15 KESSEL Oil / Fuel separator KESSEL Coalescence separator

More information

Jay R. Smith Mfg. Co.

Jay R. Smith Mfg. Co. Jay R. Smith Mfg. Co. G u i d e T o I n t e r c e p t i o n Traditional G.I. Semi-Automatic Draw-off G.I. Custom Made, Special Quote, Interceptors P.O. Box 3237 Montgomery, AL 36109-0237 Tel:334-277-8520

More information

Frequently Asked Questions about Septic Systems

Frequently Asked Questions about Septic Systems What is a septic tank? Where is my septic tank located? Do septic tanks last forever? What should and should not go into my septic tank? How can I tell if my septic tank is working properly? Why should

More information

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk 1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance

More information

Looking after your Septic Tank System

Looking after your Septic Tank System Looking after your Septic Tank System Name: Bought to you by Address: File this in your property file. 0800 TO FLUSH Call 0800 TO FLUSH 1 What do you know about your septic tank system? Just like your

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

Climate chamber with illumination

Climate chamber with illumination KBWF series (E5.2) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural

More information

Best Management Practices Fats, Oils, & Grease

Best Management Practices Fats, Oils, & Grease Best Management Practices Fats, Oils, & Grease for Food Service Facilities Public Works Department Environmental Division Table of Contents A. Introduction B. Purpose of the Manual 1 C. Frequently Asked

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The

More information

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas ACTIVITY NAME Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas CY 2014 BOTTOM LINE UP FRONT To prevent oil discharges

More information

Master Catalogue I August 2011

Master Catalogue I August 2011 Master Catalogue I August 2011 Greasing Equipment Drum Pumps Hose Reels Vehicle Hoists Wheel Service Equipment Lubrication Systems 58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile

More information

GENIX AUTOMATIC LIFTING STATIONS

GENIX AUTOMATIC LIFTING STATIONS GENIX AUTOMATIC LIFTING STATIONS GENIX AUTOMATIC LIFTING STATIONS TECHNICAL DATA Liquid temperature range: From 0 to +50 C. Liquid pumped: Sewage water containing fecal matter as regulated by EN 12050-3.

More information

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP) Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal

More information

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular

More information

Used Fluid Handling Portable Used-Oil Gravity Drains

Used Fluid Handling Portable Used-Oil Gravity Drains Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project: PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

Restaurant & café guide

Restaurant & café guide 'Helping our customers stay in business by reducing risk' NZI Risk Solutions TM About NZI Risk Solutions NZI has extensive experience in providing expert risk management advice to help our commercial customers

More information

ENERGY HYDRO POWER SOLUTIONS FOR ELECTRICAL POWER TRANSFER ELECTRICAL PROTECTION SEALING

ENERGY HYDRO POWER SOLUTIONS FOR ELECTRICAL POWER TRANSFER ELECTRICAL PROTECTION SEALING ENERGY HYDRO POWER SOLUTIONS FOR ELECTRICAL POWER TRANSFER ELECTRICAL PROTECTION SEALING MERSEN A world leader committed to Renewable Energies A world leading supplier of electrical protection, sealing,

More information

RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE (Adopted January 6, 1978)(Amended August 3, 1979)(Amended July 11, 1980) (Amended August 3, 1990)(Amended December 7, 1990) (Amended November 17, 2000) RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN

More information

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012 Plumbing Code in Commercial Kitchens NH BOA May 9, 2012 Main Topics Grease Interceptors Indirect Waste Receptors Cleaning Chemical Dispensers Thermal Expansion IPC - Chapter 10 Traps Interceptors Separators

More information

GUERNSEY OIL INSTALLATION GUIDELINES

GUERNSEY OIL INSTALLATION GUIDELINES GUERNSEY OIL INSTALLATION GUIDELINES This guidance relates only to liquid oil. For information on the requirements for associated equipment such as the positioning of boilers and flues please refer to

More information

If your campus has. Oil Pollution Prevention Rules (con.) Oil Pollution Prevention Rules (con.)

If your campus has. Oil Pollution Prevention Rules (con.) Oil Pollution Prevention Rules (con.) De-Mystifying the Oil SPCC Rules Presented by: Karen Townsend, P.E. Project Manager Woodard & Curran August 9, 2004 Agenda 1. Oil SPCC Regulatory Background 2. Highlights of 2002 Oil SPCC Amendments 3.

More information

SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE

SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE Let us help! Free professional site visit with friendly support and advice. helpingyou@klargester.com to make the right decision or call

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

CERTIFYING DRAINLAYER

CERTIFYING DRAINLAYER No. 9198 REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING DRAINLAYER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2013. All rights reserved. No part of this publication may be reproduced

More information

OREGON FIRE CODE Interpretations and Technical Advisories

OREGON FIRE CODE Interpretations and Technical Advisories OREGON FIRE CODE Interpretations and Technical Advisories A collaborative service by local and state fire professionals, along with our stakeholders and customers, to provide consistent and concise application

More information

Sewerage Management System for Reduction of River Pollution

Sewerage Management System for Reduction of River Pollution Sewerage Management System for Reduction of River Pollution Peter Hartwig Germany Content page: 1 Introduction 1 2 Total emissions 3 3 Discharge from the wastewater treatment plants 4 4 Discharge from

More information