9 Control Equipment. Control Unit System Series ConSig 8040

Size: px
Start display at page:

Download "9 Control Equipment. Control Unit System Series ConSig 8040"

Transcription

1 9 Control Equipment 01719E00 The enclosure series ConSig 40 makes it possible to assemble different control units in a clear layout. Due to the fact that a wide range of control devices is available this enclosure covers a broad field of applications. Explosion protection according to CENELEC IEC NEC For use in Zone 1 and Zone 2 Zone 21 and Zone 22 Standard and customized units 3 sizes available Enclosures in glass fibre reinforced polyester resin Up to 3 insertion points available per individual unit Control unit with 4 insertion points, see under control stations series 8146, enclosure 8146/.24. Individual units can be combined into larger units Options: flanges in brass or moulded material metal plates where metal cable entries are used equipment identification plate can be attached Contact elements 82 and 8208 with SIL certificates On request with contact element 8208 for extra low currents, with open-circuit and short-circuit monitoring 9/1Zones 1 & 2, 21 & 22

2 9 Pushbutton 40/11X-01L50BA E00 Mushroom pushbutton 01646E00 d 38 mm black 40/11X-03L24BA E00 002E E00 Mushroom stay-put button d 38 mm EM-STOP 40/11X-10L07BA E E00 d 38 mm EM-STOP 40/11X-10L07BA E E E00 Mushroom stay-put button d 55 mm EM-STOP 40/11X-15L07BA E E E00 Mushroom stay-put button key release d 38 mm EM-STOP 40/11X-09XXXBA E E00 9/2

3 9 Key-operated switch 2 40/11X-08M01XA switching positions key withdrawable in 0 + I 08750E E00 Key-operated switch 3 switching positions key withdrawable in I II 08752E00 40/11X-08M03XA Twin pushbutton 05725E00 40/11X-23D01BA E E00 Illuminated pushbutton spring return included (clear,, yellow,, blue) 015E00 40/11X-35C06BA E00 Indicating lamp Diode indicating lamp 40/11X-54C06XXXX included (clear,, yellow,, blue) 006E00 050E00 9/3

4 9 40/11X-26M01XA Selector switch with contact element 82 2 switching positions 003E E00 Selector switch with switch element 82 3 switching positions 40/11X-26M03XA E E00 051E00 Control switch, 2 pole with switch element 08 with large actuator not padlockable 40/11Z-31E...F E00 Control switch, 2 pole with switch element 08 with small actuator padlockable in 1 position 40/11Z-34E..XF with small actuator padlockable in 1 position 05726E00 9/4

5 9 40/11Z-32E..XF Control switch, 2 pole with switch element 08 with small actuator not padlockable 05711E00 Twin pushbutton 40/12X-01L13BA05-01L08BA E E00 Diode indicating lamp and pushbutton included (clear,, yellow,, blue) 09767E00 40/12X-54C06XXXX- 01L08BA E E00 Diode indicating lamp and twin pushbutton included (clear,, yellow,, blue) 09767E00 40/12X-54C06XXXX- 23D01BA E E00 9/5

6 9 Ammeter /12Z-40XXXXN Ammeter > Measurement range, see ammeter 8405 > Measuring method (direct = d or converter = W) 05576E00 Triple pushbutton 40/13X-01L13BA05-01L08BA05-01L15BA E00 011E00 052E00 2 pushbuttons with indicating lamp included (clear,, yellow,, blue) 09767E00 40/13X-54C06XXXX- 01L13BA05-01L08BA E00 012E E00 9/6

7 Twin pushbutton with mushroom stay-put button key release and indicating lamp included (clear,, yellow,, blue) 09767E00 40/13X-54C06XXXX- 23D01BA05-09XXXBA05 013E E00 Ammeter 8405 and control switch 08, 2 pole Ammeter > Measurement range, see ammeter 8405 > Measuring method (direct = d or converter = W) 40/13Z-40XXXXN..- 31E...F E00 Control switch 08, 4 pole with large actuator not padlockable 40/23Z-31E...F E00 9/7

8 Control switch, 4 pole and ammeter Control switch 08 4 pole, with large actuator not padlockable, ammeter /23Z-40XXXXN..- 31E...F. Ammeter > Measurement range > Measuring method (direct = d or converter = W) 05777E00 Control switch, 4 pole and indicating lamp Control switch 08 4 pole, with large actuator not padlockable 40/23Z-54C06XXXX- 31E...F Indicating lamp 10 > included (clear,, yellow,, blue) 05778E00 Technical Data Explosion protection Gas explosion protection E II 2 G Ex edqm ia/ib [ia/ib] II, IIA, IIB, IIC, T6, T5 or T4 Dust explosion protection E II 2 D Ex td A21 IP 65 T C, T 95 C, T 130 C Certificates Gas explosion protection PTB 01 ATEX 1105 Dust explosion protection PTB 01 ATEX 1105 Other certificates Rated voltage Rated current SIMTARS (Australia), CSA (Canada), UL (USA), CTB (Russia), UL do Brasil (Brazil) max. 690 V, AC depends on components used Operating temperature range - 20 C C - 50 C C on request Cable entry Standard: Special: 1 x M 25 x 1.5; cable gland 8161; side below (D); directly mounted into enclosure wall in side C (top) and/or side D (below); 1 x M 20 x 1.5; 1 x M 25 x 1.5 metal cable glands are possible; mounting of metal cable glands in metal flange or via metal adapter plate Max. cross-section for connection 2.5 mm 2 Terminal tightening torque max. 1.2 Nm Flanges In standard design the enclosures are without flanges. On request they can be fitted with flanges on sides C and D. Flanges are available in: polyester resin or in brass. Type of Protection IP66 Material Enclosure material Polyester resin (glass fibre-reinforced) Seal PU foam Cover fixing M 4, cheese head screws, imprescriptible, stainless steel 9/8

9 9 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 70 C C A B A B Ø5,50 Ø5,50 D D 04582E00 ConSig 40/11 ConSig 40/ E00 70 C C A B A B ,50 93 Ø5,50 Ø5,50 D 045E E E00 ConSig 40/13 ConSig 40/23 ConSig 40/11 and ConSig 40/12 combination a D Dim. a [mm] min. max. M M E00 Additional dimensions for cable entries Series 8161 Flange Dim. b [mm] Brass 16 b Moulded material 16 Additional dimensions for flanges 04585E00 We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustrations cannot be conside binding. 9/9

Control and Distribution Boxes made of Stainless Steel Series 8150

Control and Distribution Boxes made of Stainless Steel Series 8150 www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

9 Control Equipment. Control Button Series 8082

9 Control Equipment. Control Button Series 8082 9 Control Equipment Control Button 01706E00 contact elements enable contact blocks to be combined easily; using an actuator in the 8602 series, regardless of the type of actuator, up to 4 contact elements

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Control Stations Made of Polyester Resin Series 8146

Control Stations Made of Polyester Resin Series 8146 ontrol Stations Made of Polyester Resin www.stahl.de > s made of glass-fibre reinforced polyester resin > 8 basic enclosure sizes with various enclosure heights > an be combined to larger units > Equipped

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Control Stations in Sheet steel or Stainless Steel Series 8125

Control Stations in Sheet steel or Stainless Steel Series 8125 ontrol Stations in Sheet steel or Stainless Steel www.stahl.de > in electropolished stainless steel 1.4404 (ISI 316L) or zinc-galvanised sheet steel painted > 6 basic enclosure sizes with different enclosure

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP) Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal

More information

Flameproof Audible Signal 115 db (A) Series YA90

Flameproof Audible Signal 115 db (A) Series YA90 Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

ConSig 8040 Series CONTROLS. 8040 Features:

ConSig 8040 Series CONTROLS. 8040 Features: ConSig 8040 Series CONTROLS CONTROL & SIGNALING STATIONS 8040 Features: Attractive space efficient design. A variety of enclosure sizes made of Fiberglass Reinforced Polyester (FRP). Snap-on mounting of

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information

Explosion Proof Combination Signal - 110 db (A) / 5 Joule Series YL60

Explosion Proof Combination Signal - 110 db (A) / 5 Joule Series YL60 www.stahl.de Explosion Proof Combination Signal - 110 db (A) / 5 Joule > Omnidirectional high output sounder 110 db (A) / 1 m > 5 Joule xenon strobe > 2 stage alarm, independently selectable 2nd stage

More information

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design .8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms

More information

Technical data sheet TDS0070

Technical data sheet TDS0070 Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier

More information

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES Gas explosion protection II 2G Ex d IIC T6 Gb (suitable for Zone1 and Zone 2) Dust explosion protection II 2D Ex tb IIIC

More information

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent

More information

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.

98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC. 81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures

More information

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107 Supplementary instructions Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family Document ID: 4107 Contents Contents 1 For your safety 1.1 Appropriate use...

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Thermometer in stainless steel with capillary and switch contacts

Thermometer in stainless steel with capillary and switch contacts Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy

More information

Switches SWITCHES SWITCHES

Switches SWITCHES SWITCHES Switches Manufactured from Stainless Steel, Bulgin s extensive range of vandal resistant security switches are designed with a high resistance to wear and tear, corrosion and harsh use in potentially hostile

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns for harsh & hazardous (classfied) locations Construction Demolition Maintenance Turnarounds Shutdowns D-13 temporary / mobile power Temporary power products are used on industrial and construction sites

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Technical Information RIA14

Technical Information RIA14 TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical

More information

Safety instructions VEGADIS DIS81.CEIA/V****

Safety instructions VEGADIS DIS81.CEIA/V**** Safety instructions VEGADIS DIS81.CEIA/V**** CSA 14.2662675 Ex d IIC T6 T1 Gb 0044 Document ID: 48926 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application

More information

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building.

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building. Edition 02/2016 HMI s Series Characteristics The compact Series is especially suited for: Functions The Series incorporates the following functions: Market segments The EAO series is used in the following

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: 21/4 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action

More information

Switches and Indicators. Swisstac

Switches and Indicators. Swisstac Switches and Indicators Switches and Indicators Index Series Description Page 583 Product Assembly Page 584 Mounting Instruction Page 585 Product Range - pushbuttons for standard mounting - pushbuttons

More information

Terminal Box. Specifications TNCN

Terminal Box. Specifications TNCN Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Operating Instructions

Operating Instructions Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

Communication & Networking

Communication & Networking Overview (Actuator Sensor Interface) s MicroSmart Pentra Master Module Pg. 247 73W 145W Pg. 251 SX5A Safety Monitor Pg. 292 Flat Cable Connector SX5A Safety Communication Terminal (Safety Slave) Pg. 292

More information

Microcor Wireless Transmitter (MWT)

Microcor Wireless Transmitter (MWT) Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments

More information

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant GAI-TRONICS A Hubbell Company PAGE/PARTY Solutions GAI-Tronics Page/Party communication systems provide paging and party-line capabilities... two important plant communication functions in one durable,

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall

More information

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution

More information

ASSEMBLED SOCKET-COMBINATIONS

ASSEMBLED SOCKET-COMBINATIONS ASSEMBLED SOCKETCOMBINATIONS Enclosure extra strong, schockresistant easily open, it provides a comfortable mount it can be connected across a cable gland it consists of a 35 mm mounting rail Window 6

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

New Media Power Socket Outlets. New Media Power Socket Outlets

New Media Power Socket Outlets. New Media Power Socket Outlets New Media Power Socket Outlets The New Media Modules offer a flexible build solution to a host of individual power socket outlet requirements. The clip fit grid modules are simple to install in their blank

More information

Guide rail bracket (for adjustable heads)

Guide rail bracket (for adjustable heads) (for adjustable heads) Part. 209 40 ø,5 ø10,5 2 2,5 115 15 42 5 11 37 72 4 70 Code 209 / 0754 MATERIALS: Bracket made out of reinforced polyamide black colour. FEATURES: To be used with heads Part.221,

More information

AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR

AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 )

More information

2010-2011. Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

2010-2011. Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches. 2010-2011 Solutions for appliance & electronic applications Shortform Catalogue rocker lever push vandal resistant slide door snap-action & safety rotary IEC sockets fuseholders indicators A trading name

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Operating Instructions

Operating Instructions Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Control and Signaling Units

Control and Signaling Units Control and Signaling Table of Contents Page Specifications... 3 Constructions Characterisitics... 3 Ordering Guide... 4 Pushbutton... 5 Double Pushbutton... 6 Emergency (Mushroom Head)... 6 Selector...

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

AC SERIES DUAL 1/4 (6.35mm) / XLR

AC SERIES DUAL 1/4 (6.35mm) / XLR AC SERIES DUAL 1/4 (6.35mm) / XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 ) phone jack

More information

Solid as a rock Soliroc

Solid as a rock Soliroc Solid as a rock Soliroc SOLUTIONS FOR EXPOSED OR UNSUPERVISED ENVIRONMENTS Think Soliroc for strength and design in exposed areas at the mercy of vandals and other abuse. The IK 10 Soliroc TM guarantees

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

Quick Connect Boxes Inside Gloveboxes

Quick Connect Boxes Inside Gloveboxes ULC Series Junction Boxes Quick Connect Boxes Inside Gloveboxes The ULC quick connect junction boxes are the essential elements to optimize the cabling inside gloveboxes. Large range Designed for nuclear

More information

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia. Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

TEIP11-PS I/P signal converter for standard signals. Measurement made easy Change from one to tw o c olumns Data Sheet 10/18-0.10-EN Rev. C TEIP11-PS I/P signal converter for standard signals Measurement made easy Proven and reliable concept Compact design Small dimensions, low

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information