Micro Motion ELITE Mass Flow and Density Meters
|
|
|
- Bertram Davidson
- 9 years ago
- Views:
Transcription
1 Product Data Sheet PS-00374, Rev. F June 2006 Micro Motion ELITE Mass Flow and Density Meters With MVD Technology Unsurpassed performance: mass flow accuracy to ±0.05% of rate, and density accuracy to ± g/cm3 (±0.2 kg/m3) For mass and volume flow measurement of both gases and liquids Wide range of sizes from 1/10 to 6 (3 mm to 150 mm) Now available with Micro Motion s newest transmitter, the Model 2400S SERV' INSTRUMENTATION
2 Micro Motion ELITE mass flow and density meters Micro Motion ELITE meters are the leading meters for precision flow and density measurement. ELITE meters offer the most accurate measurement available for virtually any process fluid, while exhibiting exceptionally low pressure drop. Every ELITE meter features standard secondary containment, and is available with stainless steel or nickel alloy wetted parts and a wide variety of process connections to meet your every need. ELITE meters have been designed for special applications. The CMF010 provides remarkably high performance in low-flow applications. The high-pressure CMF010P is suitable for applications up to 6000 psi (413 bar). The Model CMF400 meter offers the most accurate measurement available in a high-capacity meter. Models CMF200, CMF300, and CMF400 are available in high-temperature and extreme hightemperature versions that provide accurate measurements in severe environments up to 800 F (427 C). Product selector program Micro Motion offers an on-line program for finding the best products to fit your application. The product selector program allows you to specify the parameters that matter to you, such as accuracy, flow capacity, pressure drop, or turndown. To use the product selector program, visit our web site at Contents Liquid flow performance Gas flow performance Density performance (liquid only) Power consumption Vibration limits Temperature specifications Pressure ratings Environmental effects Hazardous area classifications Materials of construction Weight Dimensions Fitting options Ordering information Micro Motion ELITE Flow and Density Meters
3 Liquid flow performance Mass Volume (1) lb/min kg/h gal/min l/h bbl/hr m 3 /h Maximum flow rate CMF CMF CMF CMF , ,200 CMF , , CMF300 10, , , CMF400 20, , , Mass and volume flow accuracy (2)(3) Model 2400S transmitter or enhanced core processor ±0.05% of rate (4)(5) Transmitter with MVD Technology All other transmitters ±0.10% of rate (6) ±0.10% ±[(zero stability / flow rate) 100]% of rate Mass and volume flow repeatability Model 2400S transmitter or enhanced core processor (4) (5) ±0.025% of rate Transmitter with MVD Technology All other transmitters ±0.05% of rate (6) ±0.05% ±[½(zero stability / flow rate) 100]% of rate lb/min kg/h Zero stability CMF CMF010P CMF CMF CMF CMF CMF CMF (1) Specifications for volumetric flow rate are based on a process-fluid density of 1 g/cm 3 (1000 kg/m 3 ). For fluids with density other than 1 g/cm 3 (1000 kg/m 3 ), the volumetric flow rate equals the mass flow rate divided by the fluid s density. (2) Stated flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications for liquids are based on reference conditions of water at 68 to 77 F (20 to 25 C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted. (3) The calibration option for ±0.05% flow accuracy is not available with high-temperature sensor models or Model CMF010P. (4) When flow rate is less than zero stability / , accuracy = ±[(zero stability / flow rate) 100]% of rate, and repeatability = ±[½(zero stability / flow rate) 100]% (5) When ordered with the ±0.10% factory calibration option, accuracy on liquid = ±0.10% when flow rate zero stability / When flow rate < zero stability / 0.001, accuracy equals ±[(zero stability / flow rate) 100]% of rate and repeatability equals ±[½(zero stability / flow rate) 100]% of rate. (6) When flow rate is less than zero stability / 0.001, accuracy equals ±[(zero stability / flow rate) 100]% of rate and repeatability equals ±[½(zero stability / flow rate) 100]% of rate. Micro Motion ELITE Flow and Density Meters 3
4 Liquid flow performance continued Typical accuracy, turndown, and pressure drop with CMF100 and 2400S transmitter or enhanced core processor The graph below is an example of the relationship between accuracy, turndown, and pressure drop when measuring the flow of water with a Model CMF100 sensor and Model 2400S transmitter or enhanced core processor. Actual pressure drop is dependent on process conditions. To determine accuracy, turndown, and pressure drop with your process variables, use Micro Motion s product selector, available at :1 20:1 1:1 Accuracy, % :1 2: Flow rate, % of maximum Turndown from maximum flow rate 500:1 100:1 20:1 10:1 2:1 Accuracy (±%) Pressure drop psi ~0 ~ bar ~0 ~ Micro Motion ELITE Flow and Density Meters
5 Gas flow performance When selecting sensors for gas applications, measurement accuracy is a function of fluid mass flow rate independent of operating temperature, pressure, or composition. However, pressure drop through the sensor is dependent upon operating temperature, pressure, and fluid composition. Therefore, when selecting a sensor for any particular gas application, it is highly recommended that each sensor be sized using Micro Motion s product selector, available at Mass Volume (1) lb/min kg/h SCFM Nm 3 /h Flow rates that produce approximately 10 psid (0.68 bar) pressure drop on air at 68 F (20 C) and 100 psi (6.8 bar) CMF010M, CMF010H CMF010P CMF CMF CMF CMF CMF , ,300 CMF ,000 16,600 26,250 Flow rates that produce approximately 50 psid (3.4 bar) pressure drop on natural gas (MW ) at 68 F (20 C) and 500 psi (34.0 bar) CMF010M, CMF010H CMF010P CMF CMF CMF CMF ,200 13,000 20,500 CMF ,500 43,000 68,000 CMF , , ,000 (1) Standard (SCFM) reference conditions are 14.7 psia and 68 F. Normal (Nm 3 /h) reference conditions are bar and 0 C. Micro Motion ELITE Flow and Density Meters 5
6 Gas flow performance continued Mass flow accuracy (1) Transmitters with MVD Technology (including Model 2400S) ±0.35% of rate (2) All other transmitters ±0.50% of rate ± zero stability 100 % of rate flow rate Mass flow repeatability Transmitters with MVD Technology (including Model 2400S) ±0.20% of rate (2) All other transmitters ±0.25% of rate ± zero stability 100 % of rate flow rate lb/min kg/h Zero stability CMF CMF010P CMF CMF CMF CMF CMF CMF (1) Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. (2) When flow rate is less than zero stability / , accuracy equals ±[(zero stability / flow rate) 100]% of rate and repeatability equals ±[½(zero stability / flow rate) 100]% of rate. 6 Micro Motion ELITE Flow and Density Meters
7 Gas flow performance continued Typical mass flow accuracy and pressure drop with CMF100 and transmitter with MVD Technology Air at 68 F (20 C), static pressures as indicated on graph psi bar Inches H 2 O Accuracy (± % of rate) psig (7 bar) 500 psig (35 bar) 1000 psig (70 bar) Pressure drop 0.1 lb/min kg/hr Flow rate Natural gas (MW ) at 68 F (20 C), static pressure as indicated on graph psi bar Inches H 2 O Accuracy (± % of rate) psig (7 bar) 500 psig (35 bar) 1000 psig (70 bar) Pressure drop 0.1 lb/min kg/hr Flow rate Standard or Normal Volumetric Capability Standard and normal volumes are quasi mass flow units for any fixed composition fluid. Standard and normal volumes do not vary with operating pressure, temperature, or density. With knowledge of density at standard or normal conditions (available from reference sources), a Micro Motion meter can be configured to output in standard or normal volume units without the need for pressure, temperature, or density compensation. Contact your local sales representative for more information. Micro Motion ELITE Flow and Density Meters 7
8 Density performance (liquid only) With 2400S transmitter or enhanced core processor With transmitter with MVD Technology (except Model 2400S), standard core processor, or RFT9739 transmitter With IFT9701 transmitter g/cm 3 kg/m 3 g/cm 3 kg/m 3 g/cm 3 kg/m 3 Accuracy (1) Model CMF010 and high-temperature models ± ±0.5 ± (2) ±0.5 (2) ±0.002 (2) ±2.0 (2) All other models ± ±0.2 ± ±0.5 ±0.002 ±2.0 Repeatability Model CMF010 and high-temperature models ± ±0.2 ± (2) ±0.2 (2) ±0.001 (2) ±1.0 (2) All other models ± ±0.1 ± ±0.2 ±0.001 ±1.0 Range All models up to 5 up to 5000 up to 5 up to 5000 up to 5 up to 5000 (1) Accuracy includes the combined effects of repeatability, linearity, and hysteresis. Specifications for ± g/cm 3 (±0.2 kg/m 3 ) density accuracy are based on reference conditions of water at 68 to 140 F (20 to 60 C) and 15 to 30 psig (1 to 2 bar). All other accuracy specifications are based on reference conditions of water at 68 to 77 F (20 to 25 C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted. (2) For these combinations of sensors and transmitters, density accuracy and repeatability differ slightly from standard meter performance. Contact Micro Motion for performance data. Power consumption Meter with core processor Meter with Model 2400S transmitter Meter with Model 1700/2700 transmitter 4 watts maximum 7 watts maximum Refer to transmitter documentation Vibration limits Meets IEC , endurance sweep, 5 to 2000 Hz, 50 sweep cycles at 1.0 g 8 Micro Motion ELITE Flow and Density Meters
9 Temperature specifications Accuracy All models ±1 C ± 0.5% of reading in C Repeatability All models ±0.2 C Temperature limits (1) All models except high-temperature models (2) 176 (80) 140 (60) Mount transmitter remotely; use j-box 140 (60) Ambient temperature in F ( C) 104 (40) 68 (20) 32 (0) 4 ( 20) 40 ( 40) 76 ( 60) 112 ( 80) Mount transmitter remotely; use j-box* 113 (45) 58 ( 50) 148 ( 100) 400 ( 240) 292 ( 180) 184 ( 120) 76 ( 60) 32 (0) 140 (60) 248 (120) 356 (180) 400 (204) 464 (240) Process fluid temperature F ( C) * When ambient temperature is below 58 F ( 50 C), a core processor or Model 2400S transmitter must be heated to bring its local ambient temperature to between 58 F ( 50 C) and +140 F (+60 C). Long-term storage of electronics at ambient temperatures below 58 F ( 50 C) is not recommended. (1) Temperature limits may be further restricted by hazardous area approvals. See pages (2) The extended mount option allows the sensor case to be insulated without covering the transmitter, core processor, or junction box, but does not affect temperature ratings. Micro Motion ELITE Flow and Density Meters 9
10 Temperature specifications continued Temperature limits (1) High-temperature models 176 (80) 140 (60) Mount transmitter remotely; use j-box 104 (40) Ambient temperature in F ( C) 68 (20) 32 (0) 4 ( 20) 40 ( 40) 76 ( 60) 112 ( 80) High-temp. models Extreme high-temp. models Mount transmitter remotely; use j-box* 58 ( 50) 148 ( 100) 400 ( 240) 256 ( 160) 112 ( 80) 32 (0) 176 (80) 320 (160) 464 (240) Maximum process temperature in F ( C) 608 (320) 662 (350) 752 (400) 800 (427) 896 (480) * When ambient temperature is below 58 F ( 50 C), a core processor or Model 2400S transmitter must be heated to bring its local ambient temperature to between 58 F ( 50 C) and +140 F (+60 C). Long-term storage of electronics at ambient temperatures below 58 F ( 50 C) is not recommended. (1) Temperature limits may be further restricted by hazardous area approvals. See pages Micro Motion ELITE Flow and Density Meters
11 Pressure ratings Flow tube rating (1) psi bar 316L and 304L stainless steel sensors Hastelloy C-22 sensors High-pressure CMF010P PED compliance Sensors comply with council directive 97/23/EC of 29 May 1997 on Pressure Equipment ASME B31.3 secondary containment rating (1) Burst pressure Housing rating psi bar psi bar CMF010 (2) CMF CMF CMF CMF CMF CMF (1) For operating temperatures above 300 F (148 C), pressure needs to be derated as follows. Linear interpolation may be used between values. Flow tubes Housing 316L sensors 304L sensors Hastelloy C-22 All sensors sensors up to 300 F (up to 148 C) None None None None at 400 F (at 204 C) 7.2% derating 5.4% derating None 5.4% derating at 500 F (at 260 C) 13.8% derating 11.4% derating 4.7% derating 11.4% derating at 600 F (at 316 C) 19.2% derating 16.2% derating 9.7% derating 16.2% derating at 650 F (at 343 C) 21.0% derating 18.0% derating 11.7% derating 18.0% derating at 700 F (at 371 C) 22.8% derating 19.2% derating 13.7% derating 19.2% derating at 750 F (at 399 C) 24.6% derating 20.4% derating 15.0% derating 20.4% derating at 800 F (at 427 C) 25.7% derating 22.2% derating 16.3% derating 22.2% derating (2) Optional rupture disks for high-pressure CMF010P will burst if pressure inside sensor housing reaches 400 psi (27 bar). Micro Motion ELITE Flow and Density Meters 11
12 Environmental effects Process temperature effect Process temperature effect is defined as: For mass flow measurement, the worst-case zero offset due to process fluid temperature change away from the zeroing temperature. For density measurement, the maximum measurement offset due to process fluid temperature change away from the density calibration temperature. Process temperature effect % of maximum flow rate per C density accuracy per C (1) g/cc kg/m 3 CMF010 ± ± ±0.015 CMF025 ± ± ±0.015 CMF050 ± ± ±0.015 CMF100 ± ± ±0.015 CMF200 ± ± ±0.015 CMF300 ± ± ±0.015 CMF400 ± ± ±0.015 Pressure effect Pressure effect is defined as the change in sensor flow and density sensitivity due to process pressure change away from the calibration pressure. Pressure effect can be corrected. Pressure effect on flow accuracy % of rate per psi % of rate per bar CMF010 None None CMF025 None None CMF050 None None CMF CMF CMF CMF g/cc per psi Pressure effect on density accuracy kg/m 3 per bar CMF010 None None CMF CMF CMF CMF CMF CMF (1) For 100 C and above. 12 Micro Motion ELITE Flow and Density Meters
13 Hazardous area classifications UL (1) All models with core processor All models with junction box Ambient temperature: 40 F ( 40 C) to +104 F (+40 C) Class I, Div. 1, Groups C and D Class I, Div. 2, Groups A, B, C, and D Class II, Div.1, Groups E, F, and G Ambient temperature: +104 F (+40 C) maximum Class I, Div. 1, Groups C and D Class I, Div. 2, Groups A, B, C, and D Class II, Div.1, Groups E, F, and G CSA and CSA C-US (2) All models (except CMF400) with Model 2400S transmitter CMF400 with Model 2400S transmitter All models with core processor or enhanced core processor All models with junction box Ambient temperature: 40 F ( 40 C) to +140 F (+60 C) Class I, Div 2, Groups A, B, C and D Class II, Div 2, Groups F and G Ambient temperature: 58 F ( 50 C) to +140 F (+60 C) Class I, Div 2, Groups A, B, C and D Class II, Div 2, Groups F and G Ambient temperature: 40 F ( 40 C) to +140 F (+60 C) Class I, Div. 1, Groups C and D Class I, Div. 2, Groups A, B, C, and D Class II, Div.1, Groups E, F, and G Ambient temperature: +140 F (+60 C) maximum Class I, Div. 1, Groups C and D Class I, Div. 2, Groups A, B, C, and D Class II, Div.1, Groups E, F, and G (1) The following products are not available with UL approval: sensors with enhanced core processor or Model 2400S transmitter; high temperature sensors; extreme high-temperature sensors. (2) The following products are available only with CSA C-US approval (i.e., not CSA): sensors with enhanced core processor or Model 2400S transmitter; high temperature sensors; extreme high-temperature sensors. Micro Motion ELITE Flow and Density Meters 13
14 Hazardous area classifications continued IECEx and NEPSI All models (except CMF400) with Model 2400S transmitter CMF400 with Model 2400S transmitter CMF010, CMF025, CMF050, and CMF100 with core processor or enhanced core processor (1) CMF010, CMF025, and CMF050 with junction box CMF100 with junction box CMF200 and CMF300 with core processor CMF400 with core processor CMF200 and CMF300 with junction box CMF400 with junction box Ambient temperature: 40 to +131 F ( 40 to +55 C) Ex na II T1 T5 Ambient temperature: 40 to +140 F ( 40 to +60 C) Ex na II T1 T5 Ambient temperature: 40 to +131 F ( 40 to +55 C) Ex ib IIC T1 T5 Ambient temperature: 400 to +131 F ( 240 to +55 C) Ex ib IIC T1 T6 Ambient temperature: 76 to +131 F ( 60 to +55 C) Ex ib IIC T1 T6 Ambient temperature: 40 to +131 F ( 40 to +55 C) Ex ib IIB T1 T5 Ambient temperature: 40 to +140 F ( 40 to +60 C) Ex ib IIB T1 T5 Ambient temperature: 67 to +131 F ( 55 to +55 C) Ex ib IIB T1 T6 Ambient temperature: 90 to +140 F ( 68 to +60 C) Ex ib IIB T1 T6 (1) Approvals pending for sensors with enhanced core processor and sensors with Model 2400S. Consult factory for availability. 14 Micro Motion ELITE Flow and Density Meters
15 Hazardous area classifications continued ATEX (1) Certificate Number BVS 05 E 125 X CMF010, CMF025, CMF050, or CMF100 with Model 2400S transmitter; CMF200(M, H, or L) and CMF300(M, H, or L) with Model 2400S transmitter II 3G EEx na II T1 T5 II 3D T* C Maximum ambient temperature ( C) Derate at slope= C ambient per C fluid CMF400M with Model 2400S transmitter * The maximum surface temperature for dust is as follows: T5:T 95 C, T4:T 130 C, T3:T 195 C, T2 to T1:T 254 C. II 3G EEx na II T1 T5 II 3D T* C Process fluid temperature ( C) Maximum ambient temperature ( C) Derate at slope= C ambient per C fluid Process fluid temperature ( C) * The maximum surface temperature for dust is as follows: T5:T 95 C, T4:T 130 C, T3:T 195 C, T2 to T1:T 230 C. (1) ATEX T rating depends on the maximum temperature shown in the graphs. Micro Motion ELITE Flow and Density Meters 15
16 Hazardous area classifications continued ATEX (1) Certificate Number BVS 06 ATEX E 045 X Models CMF010, CMF025, CMF050, CMF100, CMF200(M, H, or L), and CMF300(M, H, or L) with integral core processor 0575 II 2G EEx ib IIC T1 T5 CMF010, CMF025, CMF050, CMF100, CMF200 II 2D T* C 0575 II 2G EEx ib IIB T1 T5 CMF300 II 2D T* C Maximum ambient temperature ( C) Derate at slope= C ambient per C fluid Model CMF400M with core processor * The maximum surface temperature for dust is as follows: T5:T 95 C, T4:T 130 C, T3:T 195 C, T2 to T1:T 254 C 0575 II 2G EEx ib IIB T1 T5 II 2D T* C Process fluid temperature ( C) Maximum ambient temperature ( C) Derate at slope = C ambient per C fluid Process fluid temperature ( C) * The maximum surface temperature for dust is as follows: T 95 C, T4:T 130 C, T3:T 195 C, T2 to T1:T 234 C. (1) ATEX T rating depends on the maximum temperature shown in the graphs. 16 Micro Motion ELITE Flow and Density Meters
17 Hazardous area classifications continued ATEX (1) Certificate Number BVS 06 ATEX E 045 X Model CMF010, CMF025, and CMF050 with junction box 0575 II 2G EEx ib IIC T1 T6 II 2D T* C Maximum ambient temperature ( C) * The maximum surface temperature for dust is as follows: T6:T 80 C, T5:T 95 C, T4:T 130 C, T3:T 195 C, T2 to T1:T 254 C. The minimum ambient and process fluid temperature allowed for dust is 40 C. Model CMF100, CMF200(M, H, or L) and CMF300(M, H, or L) with junction box Construction Identification Code (C.I.C.) A4 (IIC) 0575 II 2G EEx ib IIC T1 T6 II 2D T* C Process fluid temperature ( C) Maximum ambient temperature ( C) Process fluid temperature ( C) * The maximum surface temperature for dust is as follows: T6:T 80 C, T5:T 95 C, T4:T 130 C, T3:T 195 C, T2 to T1:T 254 C. The minimum ambient and process fluid temperature allowed for dust is 40 C. (1) ATEX T rating depends on the maximum temperature shown in the graphs. Micro Motion ELITE Flow and Density Meters 17
18 Hazardous area classifications continued ATEX (1) Certificate Number BVS 06 ATEX E 045 X CMF400M with junction box connected to MVD transmitter Construction Identification Code (C.I.C.) A4 (IIC) 0575 II 2G EEx ib IIC T1 T6 II 2D T* C Maximum ambient temperature ( C) Process fluid temperature ( C) * The maximum surface temperature for dust is as follows: T6:T 80 C, T5:T 95 C, T4:T 130 C, T3:T 195 C, T2: to T1:T 234 C. The minimum ambient and process fluid temperature allowed for dust is 40 C. (1) ATEX T rating depends on the maximum temperature shown in the graphs. 18 Micro Motion ELITE Flow and Density Meters
19 Hazardous area classifications continued ATEX (1) Certificate Numbers BVS 05 E 125 X and BVS 06 ATEX E 045 X CMF200(A or B), CMF300(A or B), and CMF400A II 3G EEx na II T1 T5 II 3D T* C with Model 2400S transmitter 0575 II 2G EEx ib IIB T1 T5 with core processor or Model 1700/2700 transmitter II 2D T* C Maximum ambient temperature ( C) Process fluid temperature ( C) CMF200(C or E), CMF300(C or E), and CMF400C * The maximum surface temperature for dust is as follows: T5:T 95 C, T4:T 130 C, T3:T 195 C, T2: T 290 C, T1:T 363 C. The minimum ambient and process fluid temperature allowed for dust is 40 C. II 3G EEx na II T1 T5 II 3D T* C with Model 2400S transmitter 0575 II 2G EEx ib IIB T1 T5 with core processor or Model 1700/2700 transmitter II 2D T* C Maximum ambient temperature ( C) Process fluid temperature ( C) * The maximum surface temperature for dust is as follows: T5:T 95 C, T4:T 130 C, T3:T 195 C, T2: T 290 C, T1:T 440 C. The minimum ambient and process fluid temperature allowed for dust is 40 C. (1) ATEX T rating depends on the maximum temperature shown in the graphs. Micro Motion ELITE Flow and Density Meters 19
20 Hazardous area classifications continued ATEX (1) Certificate Number BVS 06 ATEX E 045 X Model CMF200(A or B), CMF300(A or B), and CMF400A with junction box (2) 0575 II 2G EEx ib IIB T1 T6 II 2D T* C Maximum ambient temperature ( C) Process fluid temperature ( C) * The maximum surface temperature for dust is as follows: T6:T 80 C, T5:T 95 C, T4:T 130 C, T3:T 195 C, T2:T 290 C, T1:T 363 C. The minimum ambient and process fluid temperature allowed for dust is 40 C. Model CMF200(C or E) and CMF300(C or E), and CMF400C with junction box 0575 II 2G EEx ib IIB T1 T6 II 2D T* C Maximum ambient temperature ( C) Process fluid temperature ( C) * The maximum surface temperature for dust is as follows: T6:T 80 C, T5:T 95 C, T4:T 130 C, T3:T 195 C, T2:T 290 C, T1:T 440 C. The minimum ambient and process fluid temperature allowed for dust is 40 C. (1) ATEX T rating depends on the maximum temperature shown in the graphs. (2) Model CMF400(A or B) with junction box must be connected to an MVD transmitter. 20 Micro Motion ELITE Flow and Density Meters
21 Materials of construction Wetted parts (1) Stainless steel Nickel alloy CMF010 (2), CMF025, CMF050, CMF100, CMF200, and CMF L or 304L Hastelloy C-22 CMF L Not available Housing 304L stainless steel Junction box 300-series stainless steel or polyurethane-painted aluminum; NEMA 4X (IP65) Core processor 300-series stainless steel or polyurethane-painted aluminum; NEMA 4X (IP65) Model 2400S transmitter Polyurethane-painted aluminum; NEMA 4X (IP65) (1) General corrosion guides do not account for cyclical stress, and therefore should not be relied upon when choosing a wetted material for your Micro Motion sensor. Please refer to Micro Motion s corrosion guide for proper material compatibility information. (2) The Model CMF010P has nickel alloy tubes and SST fittings. Weight Weights provided are the weight of the flowmeter with 150 lb weld neck raised face flanges. With core processor or With junction box Model 2400S transmitter lb kg lb kg CMF CMF CMF CMF CMF CMF CMF Micro Motion ELITE Flow and Density Meters 21
22 Dimensions Dimensions in inches (mm) CMF010 with enhanced core processor or Model 2400S transmitter Flow 2 13/16 (71) 2 1/2 14 NPT female purge plug fitting (optional) 2 1 9/16 (40) 3 5/16 (84) 2 1/2 14 NPT female or M female 3 1/4 (83) 5 13/16 (147) 1 3/16 (29) 2 1/16 (52) 7 1/8 (180) 3 7/8 (98) 5 (127) 1 13/16 (46) Refer to CMF010 drawings on page 23 for additional sensor dimensions. For CMF010 fitting options and dimensions, see page /4 (83) Ø1 1/4 (32) 5 13/16 (147) 2 1/16 (52) 9 5/16 (236) 1 3/16 (29) 10 7/16 (265) 12 1/2 (318) Extended mount option 22 Micro Motion ELITE Flow and Density Meters
23 Dimensions continued Dimensions in inches (mm) CMF010 with core processor Flow 2x 1 9/16 (40) Extended mount option 3 5/16 (84) 2x 1/2 14 NPT female purge fitting (optional) Ø1 1/4 (32) 8 7/16 (214) 2 13/16 (71) 1/2 14 NPT female or M20 x 1.5 female 4 9/16 (116) 1 13/16 (47) 2 7/8 (73) 9 15/16 (253) 8 1/4 (209) CMF010 with junction box Flow 2x 1 9/16 (40) Extended mount option 7 3/4 (197) 3 5/16 (84) 2x 1/2" 14 NPT female purge fitting (optional) Ø1 1/4 (32) 2 13/16 (71) 3/4" 14 NPT female 3 5/16 (84) 1 13/16 (47) 2 (50) 7 5/16 (186) 8 11/16 (220) Side view with rupture disk Flange dimensions 2x 1 3/8 (35) Dim. A* face-to-face ±1/8 (±3) 7/8 (23) 2 4 3/8 (112) Dim. A* face-to-face ±1/8 (±3) 2x 5/16 (59) thru 4 9/16 (116) 7 1/8 (180) Dim. Ø B* 2x rupture disks (optional) 3 3/8 (86) 9 (229) Back view with union fittings *For dimensions A and B, see page 40. Micro Motion ELITE Flow and Density Meters 23
24 Dimensions continued Dimensions in inches (mm) CMF025 with enhanced core processor or Model 2400S transmitter Flow 2 13/16 (71) 15/16 (24) 2 1/2 14 NPT female purge plug fitting (optional) 2 2 1/4 (58) 3 5/16 (84) 2 1/2 14 NPT female or M female 7 7/16 (188) 8 1/4 (209) 1 3/16 (29) 2 1/16 (52) 1 5/8 (41) 10 (255) 3 13/16 (97) 7 1/16 (179) 4 15/16 (126) Refer to CMF025 drawings on page 25 for additional sensor dimensions. For CMF025 fitting options and dimensions, see page /4 (83) Ø1 1/4 (32) 7 7/16 (188) 2 1/16 (52) 1 3/16 (29) 10 7/16 (266) 12 9/16 (319) 9 5/16 (237) Extended mount option 24 Micro Motion ELITE Flow and Density Meters
25 Dimensions continued Dimensions in inches (mm) CMF025 with core processor Flow 15/16 (24) 2x 2 1/4 (58) Extended mount option 3 5/16 (84) 8 1/4 (209) 10 1/16 (255) 2x 1/2 14 NPT female purge fitting (optional) Ø1 1/4 (32) 2 13/16 (72) 10 (255) 1/2 14 NPT female or M20 x 1.5 female 4 11/16 (119) 1 5/8 (41) 2 15/16 (75) 10 1/16 (256) 8 5/16 (212) CMF025 with junction box Flow 15/16 (24) 2x 2 1/4 (58) Extended mount option 3 5/16 (84) 8 1/4 (209) 9 11/16 (246) 2x 1/2 14 NPT female purge fitting (optional) Ø1 1/4 (32) 1 5/8 (41) 2 13/16 (72) 10 (255) 3/4 14 NPT female 3 7/16 (87) 2 1/16 (53) 7 7/16 (190) 8 3/4 (223) Dim. A* ±1/8 (±3) 2 1 3/4 (45) Dim. A* face to face ±1/8 (±3) Dim. Ø B* 1/2 14 NPT female Union detail Wafer detail Dim. A* face to face ±1/8 (±3) Dim. B* Flange detail *For dimensions A and B, see page 41. Micro Motion ELITE Flow and Density Meters 25
26 Dimensions continued Dimensions in inches (mm) CMF050 with enhanced core processor or Model 2400S transmitter Flow 5 (126) 15/16 (24) 2 1/2 14 NPT female purge plug fitting (optional) 2 2 1/2 (63) 4 3/8 (111) 11 1/16 (281) 2 1/2 14 NPT female or M female 10 1/16 (255) 3 1/4 (82) 1 3/16 (29) 14 5/16 (364) 2 1/16 (52) 4 1/16 (103) 2 (51) 5 3/16 (132) Refer to CMF050 drawings on page 27 for additional sensor dimensions. For CMF050 fitting options and dimensions, see page /16 (185) 10 1/16 (188) 3 1/4 (83) Ø1 1/4 (32) 2 1/16 (52) 9 7/16 (240) 10 9/16 (268) 12 11/16 (322) 1 3/16 (29) Extended mount option 26 Micro Motion ELITE Flow and Density Meters
27 Dimensions continued Dimensions in inches (mm) CMF050 with core processor Flow 15/16 (24) 2 2 1/2 (63) Extended mount option 4 3/8 (111) 11 1/16 (281) 12 11/16 (322) 2 1/2 14 NPT female purge fitting (optional) Ø1 1/4 (32) 5 (126) 14 5/16 (364) 1/2 14 NPT female or M female 4 3/4 (121) 2 (51) 3 1/16 (77) 8 7/16 (214) 10 1/8 (257) CMF050 with junction box Flow 15/16 (24) 2 2 1/2 (63) Extended mount option 4 3/8 (111) 11 1/16 (281) 12 (305) 2 1/2 14 NPT female purge fitting (optional) Ø1 1/4 (32) 5 (126) 14 5/16 (364) 3/4 14 NPT female 3 1/2 (89) 2 (51) 2 3/16 (55) 7 9/16 (192) 8 7/8 (225) Dim. A* ±1/8 (±3) /16 (49) Dim. A* face to face ±1/8 (±3) Dim. Ø B* 3/4 14 NPT female Union detail Wafer detail Dim. A* face to face ±1/8 (±3) Dim. B* Flange detail *For dimensions A and B, see page 42. Micro Motion ELITE Flow and Density Meters 27
28 Dimensions continued Dimensions in inches (mm) CMF100 with enhanced core processor or Model 2400S transmitter Flow 5 15/16 (150) 1 5/16 (33) 2 3 5/16 (84) 2 1/2 14 NPT female purge plug fitting (optional) 5 3/8 (136) 15 15/16 (405) 2 1/2 14 NPT female or M female 3 1/4 (83) 14 1/8 (360) 1 3/16 (29) 21 1/2 (546) 2 1/16 (52) 4 3/4 (121) 5 15/16 (150) 8 (204) 3 9/16 (91) Refer to CMF100 drawings on page 29 for additional sensor dimensions. For CMF100 fitting options and dimensions, see page /8 (360) 3 1/4 (83) Ø1 1/4 (32) 2 1/16 (52) 10 1/8 (258) 11 5/16 (287) 13 3/8 (340) 1 3/16 (29) Extended mount option 28 Micro Motion ELITE Flow and Density Meters
29 Dimensions continued Dimensions in inches (mm) CMF100 with core processor Flow 1 5/16 (33) 2 3 5/16 (83) Extended mount option 5 3/8 (136) 15 15/16 (405) 16 13/16 (426) 2x 1/2" 14 NPT female purge fitting (optional) Ø1 1/4 (32) 5 15/16 (150) 21 1/2 (546) 1/2" 14 NPT female or M female 5 1/2 (139) 3 9/16 (91) 3 13/16 (96) 9 3/16 (233) 10 7/8 (277) CMF100 with junction box Flow 1 5/16 (33) 2 3 5/16 (83) Extended mount option 5 3/8 (136) 2x 1/2 14 NPT female purge fitting (optional) 15 15/16 (405) 16 1/8 (409) Ø1 1/4 (32) 5 15/16 (150) 21 1/2 (546) 3/4" 14 NPT female 4 1/4 (108) 2 15/16 (74) 3 9/16 (91) 8 5/16 (211) 9 5/8 (244) Wafer detail Flange detail Dim. A* ±1/8 (±3) Dim. A* face to face ±1/8 (±3) Dim. Ø B* Dim. B* *For dimensions A and B, see page 43. Micro Motion ELITE Flow and Density Meters 29
30 Dimensions continued Dimensions in inches (mm) CMF200 with enhanced core processor or Model 2400S transmitter Flow Dim A ±1/8 (±3) 1 1/2 (38) 9 1/8 (232) 7 (178) 5 7/8 (150) Dim Ø B 11 7/8 (302) 28 5/8 (727) 3 1/4 (83) 2 1/16 (52) 2 1/2 14 NPT female or M female 2 1/2 14 NPT female purge plug fitting (optional) 6 7/8 (175) 1 3/16 (29) 7 (178) 14 (356) 19 9/16 (497) 2 4 5/16 (110) 14 1/2 (368) 12 3/8 (315) 11 1/4 (286) 5 9/16 (142) Refer to CMF200 drawings on page 31 for additional sensor dimensions. For dimensions A and B, see CMF200 fitting options and dimensions on page /4 (83) Ø1 1/4 (32) 6 7/8 (175) 2 1/16 (52) 1 3/16 (29) Extended mount option 30 Micro Motion ELITE Flow and Density Meters
31 Dimensions continued Dimensions in inches (mm) CMF200 with core processor Extended mount option 1 1/2 (38) Dim. A ±1/8* (±3) Dim. Ø B* 6 1/2 (165) 4 13/16 (122) 11 7/8 (302) 10 3/16 (258) Flow 28 9/16 (726) 9 1/2 (241) 11 7/8 (301) 1/2" 14 NPT female or M female 2x 1/2" 14 NPT female purge fitting (optional) Ø1 1/4 (32) 7 (178) 14 (356) 19 9/16 (497) 2 4 5/16 (109) 5 9/16 (142) CMF200 with junction box Extended mount option 1 1/2 (38) Dim. A ±1/8* (±3) Dim. Ø B* 5 1/4 (134) 3 15/16 (100) 10 5/8 (270) 9 5/16 (236) 8 13/16 (223) 11 7/8 (301) Flow 3/4" 14 NPT female Ø1 1/4 (32) 28 9/16 (726) 2x 1/2" 14 NPT female purge fitting (optional) 7 (178) 14 (356) 19 9/16 (497) 2 4 5/16 (109) 5 9/16 (142) *For dimensions A and B, see page 44. Micro Motion ELITE Flow and Density Meters 31
32 Dimensions continued Dimensions in inches (mm) CMF300 with enhanced core processor or Model 2400S transmitter Flow Dim A ±1/8 (±3) 3 5/16 (84) 10 1/2 (266) 8 5/16 (212) 7 3/16 (183) Dim Ø B 13 7/8 (352) 38 7/16 (977) 3 1/4 (83) 2 1/16 (52) 2 1/2 14 NPT female or M female 2 1/2 14 NPT female purge plug fitting (optional) 9 3/8 (238) 1 3/16 (29) 11 (279) 22 (559) 2 5 5/8 (143) 8 3/16 (209) 30 3/16 (767) 15 7/8 (403) 13 11/16 (348) 12 9/16 (320) Refer to CMF300 drawings on page 33 for additional sensor dimensions. For dimensions A and B, see CMF300 fitting options and dimensions on page /4 (83) 2 1/16 (52) Ø1 1/4 (32) 9 3/8 (175) 1 3/16 (29) Extended mount option 32 Micro Motion ELITE Flow and Density Meters
33 Dimensions continued Dimensions in inches (mm) CMF300 with core processor Extended mount option 3 5/16 (84) Dim. A ±1/8* (±3) Dim. Ø B* 7 13/16 (199) 6 1/8 (155) 13 3/16 (335) 11 1/2 (292) Flow 38 7/16 (976) 11 15/16 (303) 13 13/16 (351) 1/2" 14 NPT female or M female 2x 1/2" 14 NPT female purge fitting (optional) Ø1 1/4 (32) 11 (279) 22 (559) 30 3/16 (767) 2 5 5/8 (143) 8 3/16 (208) CMF300 with junction box 3 5/16 (84) Dim. A ±1/8* (±3) Dim. Ø B* 6 9/16 (167) 5 1/4 (133) Extended mount option 11 15/16 (303) 10 5/8 (270) Flow 13 13/16 (351) 11 1/4 (286) 3/4" 14 NPT female Ø1 1/4 (32) 38 7/16 (976) 2x 1/2" 14 NPT female purge fitting (optional) 11 (279) 22 (559) 30 3/16 (767) 2 5 5/8 (143) 8 3/16 (208) *For dimensions A and B, see page 45. Micro Motion ELITE Flow and Density Meters 33
34 Dimensions continued Dimensions in inches (mm) CMF400 with enhanced core processor or Model 2400S transmitter Flow Dim A ±1/8 (±3) 11 11/16 (297) 9 9/16 (244) 8 7/16 (215) Dim Ø B 5 3/8 (137) 17 3/8 (441) 3 1/4 (83) 12 3/8 (314) 38 1/4 (971) 2 1/16 (52) 2 1/2 14 NPT female or M female 2 1/2 14 NPT female purge plug fitting (optional) 1 3/16 (29) 11 (279) 22 (559) 32 3/4 (832) 2 7 (177) 10 3/4 (274) 17 1/16 (434) 14 15/16 (380) 13 13/16 (351) Refer to CMF400 drawings on page 35 for additional sensor dimensions. For dimensions A and B, see CMF400 fitting options and dimensions on page /4 (83) 2 1/16 (52) Ø1 1/4 (32) 12 3/8 (314) 1 3/16 (29) Extended mount option 34 Micro Motion ELITE Flow and Density Meters
35 Dimensions continued Dimensions in inches (mm) CMF400 with core processor 5 3/8 (137) Dim. A* ±3/16 (±5) Flow 9 1/8 (231) 7 3/8 (188) Extended mount option 14 1/2 (368) 12 13/16 (325) Dim. Ø B* /8 (380) (441) Ø1 1/4 (32) 38 1/4 (971) 11 (279) 22 (559) 32 3/4 (832) 10 3/4 (274) CMF400 with junction box Extended mount option 5 3/8 (137) Dim. A ±3/16* (±5) Flow 7 11/16 (195) 6 3/8 (162) 13 1/16 (332) 11 3/4 (298) Dim. Ø B* 17 3/8 (441) 14 5/16 (363) 38 1/4 (971) Ø1 1/4 (32) 11 (279) 22 (559) 32 3/4 (832) 10 3/4 (274) *For dimensions A and B, see page 46. Micro Motion ELITE Flow and Density Meters 35
36 Dimensions continued Dimensions in inches (mm) High-temperature CMF200A, CMF200B, CMF200C, or CMF200E 5 3/4 (145) Transmitter, core processor, or junction box mounts on end of flexible conduit. Dimensions for electronics are shown on pages (813) 6 7/8 (175) Flexible conduit Minimum bend radius 2 1/8 (54) Refer to CMF200 drawings on page 31 for additional sensor dimensions. High-temperature CMF300A, CMF300B, CMF300C, or CMF300E 7 1/16 (179) Transmitter, core processor, or junction box mounts on end of flexible conduit. Dimensions for electronics are shown on pages (813) 9 3/8 (238) Flexible conduit Minimum bend radius 2 1/8 (54) Refer to CMF300 drawings on page 33 for additional sensor dimensions. 36 Micro Motion ELITE Flow and Density Meters
37 Dimensions continued Dimensions in inches (mm) High-temperature CMF400A or CMF400C 8 5/16 (211) Transmitter, core processor, or junction box mounts on end of flexible conduit. Dimensions for electronics are shown on pages (813) 12 3/8 (314) Flexible conduit Minimum bend radius 2 1/8 (54) Refer to CMF400 drawings on page 35 for additional sensor dimensions. Micro Motion ELITE Flow and Density Meters 37
38 Dimensions continued Dimensions in inches (mm) Enhanced core processor or Model 2400S transmitter mounted on high-temperature sensor flexible conduit 3 1/4 (83) 1 3/16 (29) 2 9/16 (66) 2 1/2 14 NPT female or M female 8 7/8 (225) 1 3/8 (36) 5 5/8 (142) 6 3/4 (171) 8 7/8 (225) 1 3/8 (36) 4 Ø3/8 (10) 1 3/8 (36) 1 3/8 (36) 4 9/16 (116) Model 1700/2700 transmitter mounted on high-temperature sensor flexible conduit 3 15/16 (99) 2 15/16 (74) 13/16 (21) 2 1/2 14 NPT female or M female 2 7/16 (62) 10 1/4 (261) 1 3/8 (36) 6 9/16 (167) 9 1/4 (236) 1 3/8 (36) 4 Ø3/8 (10) 1 3/8 (36) 1 3/8 (36) 4 9/16 (116) 38 Micro Motion ELITE Flow and Density Meters
39 Dimensions continued Dimensions in inches (mm) Core processor mounted on high-temperature sensor flexible conduit 2 5/8 (66) 1/2 NPT female or M female 6 5/16 (161) 4 5/8 (117) 1 3/8 (36) 4 Ø3/8 (10) 1 3/8 (36) 1 3/8 (36) 1 3/8 (36) 4 9/16 (116) Junction box mounted on high-temperature sensor flexible conduit 1 15/16 (49) 3/4 NPT female 3 9/16 (91) 1 3/8 (36) 4 15/16 (125) 4 Ø3/8 (10) 1 3/8 (36) 1 3/8 (36) 1 3/8 (36) 4 9/16 (116) Micro Motion ELITE Flow and Density Meters 39
40 Fitting options Fitting code Dim. A face-to-face inches (mm) Dim. B outside diameter inches (mm) CMF010 fitting options (1) 316L stainless steel sensors 1/2-inch 150 lb ANSI weld neck raised face flange /8 (199) 3 1/2 (89) 1/2-inch 300 lb ANSI weld neck raised face flange /16 (209) 3 3/4 (95) 1/2-inch 600 lb ANSI weld neck raised face flange /16 (221) 3 3/4 (95) 1/2-inch sanitary fitting (Tri-Clamp compatible) /16 (177) 1 (25) DN15 PN40 weld neck flange; DIN 2635 type C face /16 (189) 3 3/4 (95) DN15 PN100 weld neck flange; DIN 2637 type E face (203) 4 1/8 (105) JIS 15mm 10K weld neck raised face flange /16 (183) 3 3/4 (95) JIS 15mm 20K weld neck raised face flange /16 (183) 3 3/4 (95) 1/4-inch NPT female Swagelok size 4 VCO fitting /16 (164) 1/4-inch tube compression fitting /16 (164) 6 mm tube compression fitting /16 (164) 304L stainless steel sensors 1/2-inch ANSI 150 lb weld neck raised face flange /8 (199) 3 1/2 (89) 1/2-inch ANSI 300 lb weld neck raised face flange /16 (209) 3 3/4 (95) DN15 PN40 weld neck flange; DIN 2526 type C face /16 (189) 3 3/4 (95) Nickel alloy sensors 1/2-inch ANSI 150 lb lap joint flange /8 (199) 3 1/2 (89) 1/2-inch ANSI 300 lb lap joint flange /16 (209) 3 3/4 (95) DN15 PN40 lap joint flange; DIN 2656 type C face /16 (240) 3 3/4 (95) JIS 15mm 10K lap joint flange /16 (208) 3 3/4 (95) 1/4-inch NPT female Swagelok size 4 VCO fitting /16 (164) High-pressure CMF010P fitting options (1) 1/4-inch NPT female Swagelok size 4 VCO fitting /16 (164) 1/4-inch tube compression fitting /16 (164) 6 mm tube compression fitting /16 (164) (1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative. 40 Micro Motion ELITE Flow and Density Meters
41 Fitting options continued Fitting code Dim. A face-to-face inches (mm) Dim. B outside diameter inches (mm) CMF025 fitting options (1) 316L stainless steel sensors Wafer style; 1/2-inch ANSI (150 lb; 300 lb; 600 lb bolt kit) /8 (60) 1 13/16 (46) Wafer style, 15mm DIN 2526; type C face (PN40 bolt kit) /8 (60) 1 13/16 (46) Wafer style; 15mm DIN 2512; type N grooved face (PN40 bolt kit) /8 (60) 1 13/16 (46) Wafer style; 15mm DIN 2526; type E face (PN100 bolt kit) /8 (60) 1 13/16 (46) Wafer style; 15mm DIN 2512; type N grooved face (PN100 bolt kit) /8 (60) 1 13/16 (46) Wafer style; 15mm; standard JIS facing (10K; 20K bolt kit) /8 (60) 1 13/16 (46) 1/2-inch ANSI 150 lb weld neck raised face flange /4 (172) 3 1/2 (89) 1/2-inch ANSI 300 lb weld neck raised face flange /8 (181) 3 3/4 (95) 1/2-inch ANSI 600 lb weld neck raised face flange /8 (194) 3 3/4 (95) 1/2-inch NPT female Swagelok size 8 VCO fitting /16 (119) 1/2-inch sanitary fitting (Tri-Clamp compatible) /16 (119) 1 (25) DN15 PN40 weld neck flange; DIN 2635 type C face /16 (160) 3 3/4 (95) DN15 PN40 weld neck flange; DIN 2635 type N grooved face /16 (160) 3 3/4 (95) DN15 PN100 weld neck flange; DIN 2637 type E face /16 (176) 4 1/8 (105) DN15 PN100 weld neck flange; DIN 2637 type N grooved face /16 (176) 4 1/8 (105) JIS 15mm 10K weld neck raised face flange /8 (156) 3 3/4 (95) JIS 15mm 20K weld neck raised face flange /8 (156) 3 3/4 (95) 304L stainless steel sensors 1/2 ANSI 150 lb weld neck raised face flange /4 (172) 3 1/2 (89) 1/2 ANSI 300 lb weld neck raised face flange /8 (181) 3 3/4 (95) DN15 PN40 weld neck flange; DIN 2526 type C face /16 (160) 3 3/4 (95) Nickel alloy sensors 1/2 ANSI 150 lb lap joint flange /4 (172) 3 1/2 (89) 1/2 ANSI 300 lb lap joint flange /8 (181) 3 3/4 (95) DN15 PN40 lap joint flange; DIN 2656 type C face /16 (186) 3 3/4 (95) JIS 15mm 10K lap joint flange /8 (181) 3 3/4 (95) (1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative. Micro Motion ELITE Flow and Density Meters 41
42 Fitting options continued Fitting code Dim. A face-to-face inches (mm) Dim. B outside diameter inches (mm) CMF050 fitting options (1) 316L stainless steel sensors Wafer style; 1/2-inch ANSI (150 lb; 300 lb; 600 lb bolt kit) /2 (89) 1 13/16 (46) Wafer style; 15mm DIN 2526; type C face (PN40 bolt kit) /2 (89) 1 13/16 (46) Wafer style; 15mm DIN 2512; type N grooved face (PN40 bolt kit) /2 (89) 1 13/16 (46) Wafer style; 15mm DIN 2526; type E face (PN100 bolt kit) /2 (89) 1 13/16 (46) Wafer style; 15mm DIN 2512; type N grooved face (PN100 bolt kit) /2 (89) 1 13/16 (46) Wafer style; 15mm; standard JIS facing (10K; 20K bolt kit) /2 (89) 1 13/16 (46) 1/2-inch ANSI 150 lb weld neck raised face flange /16 (202) 3 1/2 (89) 1/2-inch ANSI 300 lb weld neck raised face flange /16 (211) 3 3/4 (95) 1/2-inch ANSI 600 lb weld neck raised face flange /16 (224) 3 3/4 (95) 3/4-inch NPT female Swagelok size 12 VCO fitting /2 (165) 3/4-inch sanitary fitting (Tri-Clamp compatible) /2 (165) 1 (25) DN15 PN40 weld neck flange; DIN 2635 type C face /2 (191) 3 3/4 (95) DN15 PN40 weld neck flange; DIN 2635 type N grooved face /2 (191) 3 3/4 (95) DN15 PN100 weld neck flange; DIN 2637 type E face /16 (205) 4 1/8 (105) DN15 PN100 weld neck flange; DIN 2637 type N grooved face /16 (205) 4 1/8 (105) JIS 15mm 10K weld neck raised face flange /4 (184) 3 3/4 (95) JIS 15mm 20K weld neck raised face flange /4 (184) 3 3/4 (95) 304L stainless steel sensors 1/2 ANSI 150 lb weld neck raised face flange /16 (202) 3 1/2 (89) 1/2 ANSI 300 lb weld neck raised face flange /16 (211) 3 3/4 (95) DN15 PN40 weld neck flange; DIN 2526 type C face /2 (191) 3 3/4 (95) Nickel alloy sensors 1/2 ANSI 150 lb lap joint flange /16 (202) 3 1/2 (89) 1/2 ANSI 300 lb lap joint flange /16 (211) 3 3/4 (95) DN15 PN40 lap joint flange; DIN 2656 type C face /2 (216) 3 3/4 (95) JIS 15mm 10K lap joint flange /4 (210) 3 3/4 (95) (1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative. 42 Micro Motion ELITE Flow and Density Meters
43 Fitting options continued Fitting code Dim. A face-to-face inches (mm) Dim. B outside diameter inches (mm) CMF100 fitting options (1) 316L stainless steel sensors Wafer style; 1-inch ANSI (150 lb bolt kit) (102) 2 1/2 (64) Wafer style; 1-inch ANSI (300 lb; 600 lb bolt kit) (102) 2 1/2 (64) Wafer style; 25mm type C face (PN40 bolt kit) (102) 2 1/2 (64) Wafer style; 25mm DIN 2512 type N grooved face (PN40 bolt kit) (102) 2 1/2 (64) Wafer style; 25mm type E face (PN100 bolt kit) (102) 2 1/2 (64) Wafer style; 25mm DIN 2512; type N grooved face (PN100 bolt kit) (102) 2 1/2 (64) Wafer style; 25mm; standard JIS face (10K; 20K; 30K bolt kit) (102) 2 1/2 (64) 1 ANSI 150 lb weld neck raised face flange /4 (235) 4 1/4 (108) 1 ANSI 300 lb weld neck raised face flange /4 (248) 4 7/8 (124) 1 ANSI 600 lb weld neck raised face flange /4 (260) 4 7/8 (124) 1 1/2 ANSI 600 lb weld neck raised face flange /8 (276) 6 1/8 (156) 1 sanitary fitting (Tri-Clamp compatible) /8 (213) 2 (50) DN25 PN40 weld neck flange; DIN 2635 type C face /16 (211) 4 1/2 (115) DN25 PN40 weld neck flange; DIN 2635 type N grooved face /16 (211) 4 1/2 (115) DN25 PN100 weld neck flange; DIN 2637 type E face /16 (246) 5 1/2 (140) DN25 PN100 weld neck flange; DIN 2637 type N grooved face /16 (246) 5 1/2 (140) JIS 25mm 10K weld neck raised face flange /16 (211) 4 15/16 (125) JIS 25mm 20K weld neck raised face flange /16 (211) 4 15/16 (125) 304L stainless steel sensors 1 ANSI 150 lb weld neck raised face flange /4 (235) 4 1/4 (108) 1 ANSI 300 lb weld neck raised face flange /4 (248) 4 7/8 (124) DN25 PN40 weld neck flange; DIN 2526 type C face /16 (217) 4 1/2 (115) Nickel alloy sensors 1 ANSI 150 lb lap joint flange /4 (235) 4 1/4 (108) 1 ANSI 300 lb lap joint flange /4 (248) 4 7/8 (124) DN25 PN40 lap joint flange; DIN 2656 type C face /16 (243) 4 1/2 (115) JIS 25mm 10K lap joint flange /16 (237) 4 15/16 (125) (1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative. Micro Motion ELITE Flow and Density Meters 43
44 Fitting options continued Fitting code Dim. A face-to-face inches (mm) Dim. B outside diameter inches (mm) CMF200 fitting options (1) 316L stainless steel sensors 1 1/2 ANSI 150 lb weld neck raised face flange /8 (581) 5 (127) 1 1/2 ANSI 300 lb weld neck raised face flange /8 (594) 6 1/8 (156) 1 1/2 ANSI 600 lb weld neck raised face flange /8 (606) 6 1/8 (156) 2 ANSI 150 lb weld neck raised face flange /8 (581) 6 (152) 2 ANSI 300 lb weld neck raised face flange /8 (594) 6 1/2 (165) 2 ANSI 600 lb weld neck raised face flange /8 (600) 6 1/2 (165) 1 1/2 sanitary fitting (Tri-Clamp compatible) (2) /8 (543) 2 (51) 2 sanitary fitting (Tri-Clamp compatible) (2) /8 (543) 2 1/2 (64) DN40 PN40 weld neck flange; DIN 2635 type C face /16 (551) 5 15/16 (150) DN40 PN40 weld neck flange; DIN 2635 type N grooved face /16 (551) 5 15/16 (150) DN40 PN100 weld neck flange; DIN 2637 type E face /8 (587) 6 11/16 (170) DN40 PN100 weld neck flange; DIN 2637 type N grooved face /8 (587) 6 11/16 (170) DN50 PN40 weld neck flange; DIN 2635 type C face /16 (557) 6 1/2 (165) DN50 PN40 weld neck flange; DIN 2635 type N grooved face /16 (557) 6 1/2 (165) DN50 PN100 weld neck flange; DIN 2637 type E face /16 (598) 7 11/16 (195) DN50 PN100 weld neck flange; DIN 2637 type N grooved face /16 (598) 7 11/16 (195) JIS 40mm 10K weld neck raised face flange /16 (548) 5 1/2 (140) JIS 40mm 20K weld neck raised face flange /16 (548) 5 1/2 (140) JIS 50mm 10K weld neck raised face flange /16 (554) 6 1/8 (156) JIS 50mm 20K weld neck raised face flange /16 (554) 6 1/8 (156) 304L stainless steel sensors 1 1/2 ANSI 150 lb weld neck raised face flange /8 (581) 5 (127) 1 1/2 ANSI 300 lb weld neck raised face flange /8 (594) 6 1/8 (156) 2 ANSI 150 lb weld neck raised face flange /8 (581) 6 (152) 2 ANSI 300 lb weld neck raised face flange /2 (597) 6 1/2 (165) DN40 PN40 weld neck flange; DIN 2526 type C face /16 (551) 5 15/16 (150) DN50 PN40 weld neck raised face flange; DIN 2526 type C face /16 (557) 6 1/2 (165) Nickel alloy sensors 1 1/2 ANSI 150 lb lap joint flange /8 (581) 5 (127) 1 1/2 ANSI 300 lb lap joint flange /8 (594) 6 1/8 (156) 2 ANSI 150 lb lap joint flange /8 (581) 6 (152) 2 ANSI 300 lb lap joint flange /8 (594) 6 1/2 (165) DN40 PN40 lap joint flange; DIN 2656 type C face /16 (551) 5 15/16 (150) DN50 PN40 lap joint flange; DIN 2656 type C face /16 (557) 6 1/2 (165) JIS 40mm 10K lap joint flange /16 (548) 5 1/2 (140) JIS 50mm 10K lap joint flange /16 (554) 6 1/8 (155) (1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative. (2) Not available with high-temperature models CMF200A, CMF200B, CMF200C, or CMF200E. 44 Micro Motion ELITE Flow and Density Meters
45 Fitting options continued Fitting code Dim. A face-to-face inches (mm) Dim. B outside diameter inches (mm) CMF300 fitting options (1) 316L stainless steel sensors 3 ANSI 150 lb weld neck raised face flange /16 (856) 7 1/2 (191) 3 ANSI 300 lb weld neck raised face flange /16 (875) 8 1/4 (210) 3 ANSI 600 lb weld neck raised face flange /16 (894) 8 1/4 (210) 4 ANSI 150 lb weld neck raised face flange /16 (865) 9 (229) 4 ANSI 300 lb weld neck raised face flange (889) 10 (254) 4 ANSI 600 lb weld neck raised face flange /16 (932) 10 3/4 (273) 3 sanitary fitting (Tri-Clamp compatible) (2) (813) 3 9/16 (90) DN80 PN40 weld neck flange; DIN 2635 type C face /8 (835) 7 7/8 (200) DN80 PN40 weld neck flange; DIN 2635 type N grooved face /8 (835) 7 7/8 (200) DN80 PN100 weld neck flange; DIN 2637 type E face /16 (878) 9 1/16 (230) DN80 PN100 weld neck flange; DIN 2637 type N grooved face /16 (878) 9 1/16 (230) DN100 PN40 weld neck flange; DIN 2635 type C face /16 (849) 9 1/4 (235) DN100 PN40 weld neck flange; DIN 2635 type N grooved face /16 (849) 9 1/4 (235) DN100 PN100 weld neck flange; DIN 2637 type E face /16 (903) 10 7/16 (265) DN100 PN100 weld neck flange; DIN 2637 type N grooved face /16 (903) 10 7/16 (265) JIS 80mm 10K weld neck raised face flange /8 (848) 7 5/16 (186) JIS 80mm 20K weld neck raised face flange /8 (848) 7 7/8 (200) JIS 100mm 10K weld neck raised face flange /16 (853) 8 1/4 (210) JIS 100mm 20K weld neck raised face flange /16 (853) 8 7/8 (225) 304L stainless steel sensors 3 ANSI 150 lb weld neck raised face flange /16 (856) 7 1/2 (191) 3 ANSI 300 lb weld neck raised face flange /16 (875) 8 1/4 (210) DN80 PN40 weld neck flange; DIN 2526 type C face /8 (835) 7 7/8 (200) Nickel alloy sensors 3 ANSI 150 lb lap joint flange /16 (856) 7 1/2 (191) 3 ANSI 300 lb lap joint flange /16 (875) 8 1/4 (210) DN80 PN40 lap joint flange; DIN 2656 type C face /8 (835) 7 7/8 (200) JIS 80mm 10K lap joint flange /8 (848) 7 5/16 (185) (1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative. (2) Not available with high-temperature models CMF300A, CMF300B, CMF300C, or CMF300E. Micro Motion ELITE Flow and Density Meters 45
46 Fitting options continued Fitting code Dim. A face-to-face inches (mm) Dim. B outside diameter inches (mm) CMF400 fitting options (1) 4 ANSI 150 lb weld neck raised face flange /16 (1021) 9 (229) 4 ANSI 300 lb weld neck raised face flange (1041) 10 (254) 4 ANSI 600 lb weld neck raised face flange /16 (1084) 10 3/4 (273) 6 ANSI 150 lb weld neck raised face flange /16 (1024) 11 (279) 6 ANSI 300 lb weld neck raised face flange /16 (1049) 12 1/2 (318) 6 ANSI 600 lb weld neck raised face flange /2 (1105) 14 (356) DN100 PN40 weld neck flange; DIN 2635 type C face /16 (999) 9 1/4 (235) DN100 PN40 weld neck flange; DIN 2635 type N grooved face /16 (999) 9 1/4 (235) DN100 PN100 weld neck flange; DIN 2637 type E face /16 (1049) 10 7/16 (265) DN100 PN100 weld neck flange; DIN 2637 type N grooved face /16 (1049) 10 7/16 (265) DN150 PN40 weld neck flange; DIN 2635 type C face /8 (1006) 11 13/16 (300) DN150 PN40 weld neck flange; DIN 2635 type N grooved face /8 (1006) 11 13/16 (300) DN150 PN100 weld neck flange; DIN 2637 type E face /16 (1065) 14 (355) DN150 PN100 weld neck flange; DIN 2637 type N grooved face /16 (1065) 14 (355) JIS 100mm 10K weld neck raised face flange /16 (999) 8 1/4 (210) JIS 100mm 20K weld neck raised face flange /16 (1011) 8 7/8 (225) JIS 150mm 10K weld neck raised face flange /8 (1006) 11 (280) JIS 150mm 20K weld neck raised face flange /8 (1018) 12 (305) (1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative. 46 Micro Motion ELITE Flow and Density Meters
47 Ordering information Model Product Description Standard models CMF010M Micro Motion Coriolis ELITE sensor; 1/10-inch; 316L stainless steel CMF010H Micro Motion Coriolis ELITE sensor; 1/10-inch; Hastelloy C-22 CMF010L Micro Motion Coriolis ELITE sensor; 1/10-inch; 304L stainless steel CMF025M Micro Motion Coriolis ELITE sensor; 1/4-inch; 316L stainless steel CMF025H Micro Motion Coriolis ELITE sensor; 1/4-inch; Hastelloy C-22 CMF025L Micro Motion Coriolis ELITE sensor; 1/4-inch; 304L stainless steel CMF050M Micro Motion Coriolis ELITE sensor; 1/2-inch; 316L stainless steel CMF050H Micro Motion Coriolis ELITE sensor; 1/2-inch; Hastelloy C-22 CMF050L Micro Motion Coriolis ELITE sensor; 1/2-inch; 304L stainless steel CMF100M Micro Motion Coriolis ELITE sensor; 1-inch; 316L stainless steel CMF100H Micro Motion Coriolis ELITE sensor; 1-inch; Hastelloy C-22 CMF100L Micro Motion Coriolis ELITE sensor; 1-inch; 304L stainless steel CMF200M Micro Motion Coriolis ELITE sensor; 2-inch; 316L stainless steel CMF200H Micro Motion Coriolis ELITE sensor; 2-inch; Hastelloy C-22 CMF200L Micro Motion Coriolis ELITE sensor; 2-inch; 304L stainless steel CMF300M Micro Motion Coriolis ELITE sensor; 3-inch; 316L stainless steel CMF300H Micro Motion Coriolis ELITE sensor; 3-inch; Hastelloy C-22 CMF300L Micro Motion Coriolis ELITE sensor; 3-inch; 304L stainless steel CMF400M Micro Motion Coriolis ELITE sensor; 4-inch; 316L stainless steel CMF010P High-pressure models Micro Motion Coriolis ELITE sensor; 1/10-inch; high pressure; nickel alloy with stainless steel fittings High-temperature models CMF200A Micro Motion Coriolis ELITE sensor; 2-inch; high temperature; 316L stainless steel CMF200B Micro Motion Coriolis ELITE sensor; 2-inch; high temperature; Hastelloy C-22 CMF200C Micro Motion Coriolis ELITE sensor; 2-inch; extreme high temperature; 316L stainless steel CMF200E Micro Motion Coriolis ELITE sensor; 2-inch; extreme high temperature; Hastelloy C-22 CMF300A Micro Motion Coriolis ELITE sensor; 3-inch; high temperature; 316L stainless steel CMF300B Micro Motion Coriolis ELITE sensor; 3-inch; high temperature; Hastelloy C-22 CMF300C Micro Motion Coriolis ELITE sensor; 3-inch; extreme high temperature; 316L stainless steel CMF300E Micro Motion Coriolis ELITE sensor; 3-inch; extreme high temperature; Hastelloy C-22 CMF400A Micro Motion Coriolis ELITE sensor; 4-inch; high temperature; 316L stainless steel CMF400C Micro Motion Coriolis ELITE sensor; 4-inch; extreme high temperature; 316L stainless steel Code Process Connections ### See process fitting options on pages Code Case Options N Standard pressure containment P Purge fittings (two 1/2-inch NPT female) D Rupture disks (two 400-psi [28 bar] disks) Model CMF010P only Continued on next page Micro Motion ELITE Flow and Density Meters 47
48 Ordering information continued Code Electronics Interface For all models except high-temperature models 0 Model 2400S transmitter 1 Extended mount Model 2400S transmitter 2 4-wire polyurethane-painted aluminum integral enhanced core processor for remote mount transmitters 4 4-wire polyurethane-painted aluminum integral extended mount enhanced core processor for remote mount transmitters Q 4-wire polyurethane-painted aluminum integral core processor for remote mount transmitters A 4-wire stainless steel integral core processor for remote mount transmitters V 4-wire extended mount polyurethane-painted aluminum integral core processor for remote mount transmitters B 4-wire extended mount stainless steel integral core processor for remote mount transmitters W (1) Polyurethane-painted aluminum integral core processor for MVD Direct Connect installation D (1) Stainless steel integral core processor for MVD Direct Connect installation Y (1) Polyurethane-painted aluminum extended core processor for MVD Direct Connect installation E (1) Stainless steel extended core processor for MVD Direct Connect installation R 9-wire polyurethane-painted aluminum junction box H 9-wire extended mount polyurethane-painted aluminum junction box S 9-wire 316L stainless steel junction box For high-temperature models 0 Model 2400S transmitter 2 4-wire polyurethane-painted aluminum integral enhanced core processor for remote mount transmitters Q 4-wire polyurethane-painted aluminum integral core processor for remote mount transmitters A 4-wire stainless steel integral core processor for remote mount transmitters C Model 1700/2700 transmitter W (1) Polyurethane-painted aluminum integral core processor for MVD Direct Connect installation D (1) Stainless steel integral core processor for MVD Direct Connect installation R 9-wire polyurethane-painted aluminum junction box S 9-wire 316L stainless steel junction box Continued on next page (1) When electronics interface code W, D, Y, or E is ordered with approval U, C, A, or Z, an MVD Direct Connect I.S. barrier is supplied. No barrier is supplied when ordered with approval codes M or N. 48 Micro Motion ELITE Flow and Density Meters
49 Ordering information continued Code A B E F G A H J Code Conduit Connections Electronics interface codes 0, 1, and C Not applicable Electronics Interface Codes 2, 4, Q, A, V, B, W, D, Y and E 1/2-inch NPT no gland M20 no gland Brass/nickel cable gland (cable diameter to inches [8.5 to 10 mm]) Stainless steel cable gland (cable diameter to inches [8.5 to 10 mm]) Electronics Interface Codes R, H, and S (9-wire junction box) 3/4-inch NPT no gland Brass nickel cable gland Stainless steel cable gland Approvals Electronics interface codes 0 and 1 M Micro Motion Standard (no approval) N Micro Motion Standard / PED compliant 2 CSA C-US (US and Canada) Class I, Div. 2 V ATEX Equipment Category 3 (Zone 2) / PED compliant M N A Z Electronics interface codes 2 and 4 Micro Motion Standard (no approval) Micro Motion Standard / PED compliant CSA C-US (US and Canada) ATEX Equipment Category 2 (Zone 1) / PED compliant Electronics interface codes Q, A, C, V, B, R, H, and S M Micro Motion Standard (no approval) N Micro Motion Standard / PED compliant U UL Not available with electronics interface code C C CSA (Canada only) Not available with electronics interface code C A CSA C-US (US and Canada) Z ATEX Equipment Category 2 (Zone 1) / PED compliant P (1) NEPSI I IECEx Zone 1 Electronics interface codes W, D, Y, and E (MVD Direct Connect with I.S. Barrier) (2) M Micro Motion Standard (no approval, no barrier included) N Micro Motion Standard / PED compliant (no approval, no barrier included) U UL C CSA (Canada only) A CSA C-US (US and Canada) Z ATEX Equipment Category 2 (Zone 1) / PED compliant Continued on next page (1) Available only with language option M (Chinese). (2) When electronics interface code W, D, Y, or E is ordered with approval U, C, A, or Z, an MVD Direct Connect I.S. barrier is supplied. No barrier is supplied when ordered with approval codes M or N. Micro Motion ELITE Flow and Density Meters 49
50 Ordering information continued Code A D E F G H I J M N O P S W B C K T U L V Y Language Danish installation manual Dutch installation manual English installation manual French installation manual German installation manual Finnish installation manual Italian installation manual Japanese installation manual Chinese installation manual Norwegian installation manual Polish installation manual Portuguese installation manual Spanish installation manual Swedish installation manual Hungarian CE requirements document and English installation manual Czech installation manual Slovak CE requirements document and English installation manual Estonian CE requirements document and English installation manual Greek CE requirements document and English installation manual Latvian CE requirements document and English installation manual Lithuanian CE requirements document and English installation manual Slovenian CE requirements document and English installation manual Code (1) Calibration Options Z 0.10% mass flow and g/cm 3 (0.5 kg/m 3 ) density D 0.10% mass flow and g/cm 3 (0.2 kg/m 3 ) density % mass flow and g/cm 3 (0.5 kg/m 3 ) density % mass flow and g/cm 3 (0.2 kg/m 3 ) density Code Measurement Application Software Z No measurement application software A (2) Petroleum measurement Code Factory Options Z Standard product X ETO product R Restocked product (if available) Typical Model Number: CMF050M 313 N 2 B A E Z Z Z (1) Calibration options other than Z require electronics interface codes 0, 1, or 2. In addition, for high-temperature models, only calibration option Z is available. (2) Available with electronics interface code W, D, Y, and E. For electronics interface codes 0, 1, 2, 4, Q, A, V, B, R, H, and S, select the transmitter s Petroleum Measurement software option. 50 Micro Motion ELITE Flow and Density Meters
51 Micro Motion ELITE Flow and Density Meters 51
52 2006 Micro Motion, Inc. All rights reserved. P/N PS-00374, Rev. F Due to Micro Motion s commitment to continuous improvement of our products, all specifications are subject to change without notice. ELITE, ProLink, and the Micro Motion logo are registered trademarks, and MVD and MVD Direct Connect are trademarks of Micro Motion, Inc., Boulder, Colorado. The Emerson logo is a trademark of Emerson Electric Co. All other trademarks are property of their respective owners. For the latest Micro Motion product specifications, view the PRODUCTS section of our web site at
Micro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
OPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
OPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
Micro Motion ELITE CMFS Series Meter
Revolutionize your Coriolis measurement technology Micro Motion ELITE CMFS Series Meter Introducing Emerson s Micro Motion Elite CMFS Series METER Our ELITE CMFS meter delivers unmatched, real-world performance
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter
www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding
ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors
Installation Instructions P/N MMI-20015054, Rev. AA May 2009 ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors For ATEX-approved sensor installations Note: For hazardous installations
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
Micro Motion 7829 Visconic Viscosity Meter
Product Data Sheet PS-001183, Rev. C April 2013 Micro Motion 7829 Visconic Viscosity Meter Micro Motion viscosity meters are built to tackle the most demanding industrial and process applications. Rugged
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
Mass Flow Meters & Controllers
HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2% of Full Scale) 0-5 VDC or 4-20
Thermatel Model TA1 Mass Flow Transmitter
Thermatel Model TA1 Mass Flow Transmitter D E S C R I P T I O N Thermatel Thermal Mass Flow Transmitter, Model TA1, provides a high level of performance in mass flow measurement of air and gases. Powerful
ATEX Zone 2 and 22 Installation Drawings and Instructions
Installation Instructions P/N 20004425, Rev. CA June 2009 ATEX Zone 2 and 22 Installation Drawings and Instructions For ATEX-approved Zone 2 and 22 installations Note: For hazardous installations in Europe,
Micro Motion LF-Series Low Flow Sensor and Transmitter
Product Data Sheet PS-00566, Rev. G April 2013 Micro Motion LF-Series Low Flow Sensor and Transmitter Micro Motion LF-Series meters are the smallest Coriolis meters on the market, with a form factor the
Turbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
Thermal Mass Flow Meter (Series MST)
Overview MaxiFlo TM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant
Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters
Data Sheet Brooks Digital MFC's & MFM's Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters GENERAL FEATURES Wide FS flow range for measurement
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
Variable Area Flowmeters
www.swagelok.com Variable Area Flowmeters G Series and M Series Glass and metal (armored) tube models, including miniature armored model Highly accurate measurement with individually calibrated scales
Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms
Data Sheet Models MT 3809 & 3819 Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms Broad range of flow capacities 2% Full scale accuracy Versatile
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
Rosemount 1199 Submersible Seal
Product Data Sheet July 2013 00813-0400-4016, Rev AA The Rosemount Submersible Seal design uses innovative DP level technology to measure level for top-down applications. For this design, the seal and
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features
GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high
Rosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
FCI ST75 Series Flow Meters
FCI ST75 Series Flow Meters Small Line, Mass Flow Meters for Industrial and Commercial Process Gases Low cost, easy installation flow measuring for 1/4 inch to 2 inch [6 mm to 51 mm] line sizes FCI ST75
Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)
Product Data Sheet July 2015 00813-0200-2654, Rev KA Rosemount DIN-Style Temperature Sensors and Thermowells (Metric) RTDs (0065) and thermocouples (0185) available to meet any process requirement DIN-style
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI 01 2010
Overview are designed for measuring the flow of electrically conductive mediums. The full program consists of three different types of flowmeters making Siemens unique in that it covers all possible applications
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision J Features 4 to 20
Immersible Thermal Gas Mass Flow Meter FeaTures DescrIpTIon
Immersible Thermal Gas Mass Flow Meter Features n Direct mass flow monitoring eliminates need for separate temperature and pressure inputs n Accuracy +/- 1% of reading plus 0.5% of full scale n Patented
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MG Transmitter with Digital Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MG Transmitter with Digital Output SENSORS Document Part Number 550784 Revision J Data Sheet FEATURES Modbus
Model 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve
High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures
SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version
instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
B-Series Temperature Switches
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
VersaFlow Mag 100 Electromagnetic Flow Sensor Specifications
VersaFlow Mag 100 Electromagnetic Flow Sensor Specifications 34-VF-03-08 September 2009 The Economical Solution The VersaFlow Mag 100 flow sensor is an economical solution for a wide range of applications.
StackFlowMaster FPD581, FPD583 and FPD585 Stack gas metering systems
Data sheet DS/FPD580 EN Rev. B StackFlowMaster FPD58, FPD583 and FPD585 Stack gas metering systems Measurement made easy Flow metering solutions for Continuous Emissions Monitoring (CEMS) Continuous measurement
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Installation Manual 20002158, Rev DK November 2015. Micro Motion ELITE Coriolis Flow and Density Sensors
Installation Manual 20002158, Rev DK November 2015 Micro Motion ELITE Coriolis Flow and Density Sensors Safety and approval information This Micro Motion product complies with all applicable European directives
Thermatel Enhanced Model TA2 Thermal Mass Flow Meter
Thermatel Enhanced Model TA2 Thermal Mass Flow Meter D E S C R I P T I O N The Thermatel Enhanced Model TA2 Thermal Mass Flow Meter provides reliable mass measurement for air and gas flow applications.
Rosemount 1199 Submersible Seal
Product Data Sheet January 2015 00813-0400-4016, Rev BB The Rosemount Submersible Seal design uses innovative DP Level technology to measure level for top-down applications. For this design, the seal and
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.
GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
Variable V Area Flowmeter Rotameter The Original
Variable V Area Flowmeter Rotameter The Original 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com precise measurement of liquids
Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas
Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas 34-XY-03-01, May 2012 Function The WG/A5xx is part of the XYR 5000 family of wireless products.
B-Series Switches Pressure, Differential Pressure & Hydraulic
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
Electromagnetic Flow Meter
Electromagnetic Flow Meter Description The EL 2200 series of electromagnetic sensors represent the state of the art for the accurate measurement for water cycle and process applications. Flow meters are
How To Use A Corona Mdi 110
CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output
Coriolis Flow meters. Product family introduction Principle of operation Product review Applications Key product features
Coriolis Flow meters introduction Product review s Key product features This document should not be duplicated, used, distributed, or disclosed for any purpose unless authorized by Siemens. Page 1 SITRANS
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Air Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
Micro Motion Model 2200S Transmitters
Installation Manual P/N MMI-20012740, Rev. BA February 2009 Micro Motion Model 2200S Transmitters Installation Manual 2009, Micro Motion, Inc. All rights reserved. ELITE and ProLink are registered trademarks,
Rosemount 751 Field Signal Indicator
Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available
Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP
WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams
Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020
Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
Flow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS
EPP - 1 DECRIPTION The odel 575 is used in general water/wastewater applications. The transmitter is offered in a standard non-clogging snub nose end, flush diaphragm or protected flush diaphragm with
Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications
FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications Flow Measurement Flow Switches Level Switches Level Interface Switches FCI OEM SERIES Industrial Machinery Chemical Injection
Terminal Box. Specifications TNCN
Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet
WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features
GE Measurement & Control STX2100 Differential Pressure (Flow) Transmitter Models FKC...5 The STX2100 differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
TEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
MicroMachined Silicon modular pressure sensor
MicroMachined Silicon modular pressure sensor Configurable High Accuracy High Temperature Performance For Industrial, Test and Measurement, and Aerospace Applications Low Pressure from 10 in-h 2 O to 2.5
Thermal Dispersion Mass Flow
Thermatel Thermal Dispersion Mass Flow Measurement Handbook Table of Contents Introduction...1 What is Mass Flow Measurement?...1 Types of Flow Transmitters...4 Differential Pressure...4 Orifice...4 Venturi...6
SMV 3000 Smart Multivariable Flow Transmitter
SMV 3000 Smart Multivariable Flow Transmitter Measurements and Calculations: Differential Pressure Absolute or Gauge Pressure Process Temperature via 100 ohm Pt. RTD or Type J,K,T or E Thermocouple Mass
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
Laminar Flow Elements
Laminar Flow Elements Meriam Laminar Flow Elements (LFEs) are excellent for measuring low gas flow rates from 0.2 SCCM up to 2250 SCFM. They are inherently accurate and repeatable and are calibrated traceable
Thermatel Model TD1/TD2 Thermal Dispersion Flow/Level/Interface Switch
Thermatel Model TD1/TD2 Thermal Dispersion Flow/Level/Interface Switch D E S C R I P T I O N TD1 and TD2 Thermal Dispersion flow/level/interface switches provide a new level of performance and reliability
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching