Balancing valves DN 15-50
|
|
- Elizabeth Griffith
- 7 years ago
- Views:
Transcription
1 Balancing valves DN BALLOREX VENTURI FODRV DN BALLOREX VENTURI DRV DN Advantages Regulation, isolation and flow measurement in one single unit Measurement across a Venturi nozzle Flow measurement accuracy better than +/- 3% Same measuring accuracy over the entire measuring area from 1 to 100kPa Regulation setting remains unchanged when isolated Can be installed with test points in any position No requirements for straight pipe lengths: up- or downstream BALLOREX VENTURI is a static balancing valve used to regulate flow, measure and isolate. BALLOREX VENTURI is used where there is a demand for a hydraulic balance in a heating or cooling system. This is assured by the distribution of the flow in the pipe system in accordance with the calculated requirement of heating or cooling. BALLOREX VENTURI consists of a regulation and a flow measurement unit where the pressure differential signals are generated. The flow measurement unit is a Venturi nozzle which has a unique construction through which the flow is measured. The flow is calculated based on the pressure differential measured across the Venturi nozzle. The measurement accuracy is better than +/- 3%, and this accuracy is maintained over the entire measurement range from 1 to 100kPa. 15
2 BALLOREX VENTURI can be delivered in two variations. FODRV: Includes regulation, isolation and a flow measurement unit. DRV: Includes regulation and isolation unit. DN Technical Specifications Pressure and temperature classifications FODRV DRV Temperature max. 100 C 120 C 120 C 135 C Pressure female max. 20 bar 16 bar - 16 bar Pressure compression conn. max. - 5 bar 5 bar - Material Valve body Spindle Ball & adjusting screw Gaskets O-rings Handle Measuring P/T plug Rubber in P/T plug DZR brass; CW602N CuZn36Pb2As DZR brass; CW602N CuZn36Pb2As DZR brass; CW602N CuZn36Pb2As, chrome coated PTFE EPDM Polyamide PA6.6 30%GF DZR brass; CW602N CuZn36Pb2As EPDM Markings on valve FODRV DRV Valve body DN and PN 20 DN and PN 20 Handle DN and Kvs-value DN Connection Female thread ISO 7/1 parallel Compression connections EN Pressure test According to ISO 5208: 1993E: 16
3 EXPLANATION OF FUNCTIONS Regulation The regulation needle is positioned within the isolation ball valve. The opening or closing of the needle controls the flow through the valve. The settings of the needle can be read on the digital scale of the handle where the figure on the black background shows the number of full rotations and the figure on the red background shows the 1/10 rotations. Isolation The valve can be used as an isolation valve. The regulation needle is positioned in the middle of the isolation ball; the isolation function does not alter the setting of the regulation needle. When the valve is installed, it is easy to identify if the valve is open or closed. When the handle is positioned at 90 to the pipe, it indicates that the valve is closed. When the handle is in line with the pipe, it indicates that the valve is open. Flow Measurement Flow measurement is via the Venturi nozzle. The Venturi has two pairs of outlet connections. One set for the high pressure or inlet side and one set for the low pressure or outlet side. The two sets of outlets are sealed from each other using an EPDM rubber O-ring. The pressure differential measured between the two sets of outlets can be used to calculate the actual flow passing through the Venturi. The pressure difference is measured with a BROEN FLOWMETER or equal and is converted to a flow rate in l/s or m³/h either automatically via electronic measuring equipment or manually using the calculation formula. DN Valve table and flow-range FODRV Valve Size Kvs Flow* Signal Head loss Kv Loss factor DRV Valve Size DN Description m 3 /h l/s kpa m 3 /h DN m 3 /h 15 Low flow 0,359 0,010-0, ,63 0,33 15L 1,62 15 Standard flow 0,746 0,062-0, ,62 0,21 15S 2,11 15 High flow 1,56 0,138-0, ,49 0,39 20 Low flow 0,746 0,062-0, ,43 0,27 20L 4,26 20 Standard flow 1,56 0,138-0, ,82 0,31 20S 4,81 20 High flow 2,95 0,258-0, ,72 0,27 25 Standard flow 2,95 0,258-0, ,54 0,15 25S 9,94 25 High flow 6,01 0,54-1, ,1 0,25 32 High flow 6,01 0,54-1, ,2 0,21 32S 13,3 40 High flow 9,2 0,81-1, ,0 0,17 40S 23,3 50 High flow 17,1 1,52-3, ,0 0,23 50S 35,3 * The flow rates given in the table are for water flow in steel pipes which provide a pressure loss of 100 to 500 Pa per meter pipe. Kv 17
4 BALLOREX VENTURI DN FODRV Female x Female with regulation, isolation and flow measurement functions DN Inch A B C D L L ½ S S ½ H H ½ L L ¾ S S ¾ H H ¾ S S H H H H 1 ¼ H H 1 ½ H H BROEN-No. DN Description 96M Insulating cap 96M Insulating cap 96M Insulating cap 96M Insulating cap 96M Insulating cap 96M Insulating cap sssss Measuring P/T plug (1 piece) 18
5 BALLOREX VENTURI DN FODRV Compression x Compression with regulation, isolation and flow measurement functions DN mm A B C D L L S S H H L L S S H H S S H H H H H H H H BROEN-No. DN Description 96M Insulating cap 96M Insulating cap 96M Insulating cap 96M Insulating cap 96M Insulating cap 96M Insulating cap sssss Measuring P/T plug (1 piece) 19
6 BALLOREX VENTURI DN DRV Female x Female with regulation and isolation functions DN Inch A B C D L L ½ S S ½ L L ¾ S S ¾ S S S S 1¼ S S 1½ S S BROEN-No. Description Measuring P/T plug (1 piece) 20
7 BALLOREX VENTURI DN DRV Compression x Compression with regulation and isolation functions DN mm A B C D L L S S L L S S S S S S S S S S BROEN-No. Description Measuring P/T plug (1 piece) 21
Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special
More informationThermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
More informationThermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
More informationThermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVI is self-acting thermostatic actuator primarily for use for temperature control
More information2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
More informationSelf-operated Temperature Regulators Temperature Regulator Type 1u
Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50
More informationThermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)
Data Sheet Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity) Application RAS-C² thermostatic sensor RA-FN angle valve The RAS-C² thermostatic sensor is a selfactuating proportional
More informationTA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.
TA-FUS1ON Fully adjustable Kvs control and balancing valves. That s just two good. Supported by the Reece hvac-r network. Through our 36 stores around Australia, Reece hvac-r is committed to supporting
More informationData sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G
Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G EN 215-1 HD 1215-2 Application RA 2910 built-in sensor RA 2920 tamperproof RA 5062 remote sensor temperature adjuster RA-FN
More informationRADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS
RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS MANIFOLD ASSEMBLIES ONE-PIPE Compatible with most radiators on the market, this pre-assembled manifold for one-pipe radiator systems delivers balancing
More informationCRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size
CRANE Σελίδα από 2 DM93 Variable Orifice Double Regulating Valve PN6 Cast Iron Balancing Valve (VODRV), Flanged to BSEN 92-2 The DM93 variable orifice double regulating valves will give satisfactory performance
More informationType overview. Technical data
Technical data sheet R3..xx-S.. Characterised control valve, 3-way, Internal thread For closed cold and warm water systems For modulating water-side control of air handling units and heating systems ir
More informationOverview of types. Technical data
Technical data sheet R3..xx-S.. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems For modulating water-side control of HU and heating systems ir bubble-tight
More informationV5001S. Kombi-S Shutoff Valve. Product specification sheet
V5001S Kombi-S Shutoff Valve Product specification sheet Application The V5001S Kombi-S shutoff valve is used to shutoff pipelines in residential or commercial hydronic heating and cooling systems. It
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationDouble-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.
Picture Item No. Description RO- 0010 Brass Water Feed 1. 3/4" FIP with 1/4" hole 2. Using on R.O. tank RO- O020 Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP RO- 0030 Brass
More informationstainless steel pre-assembled manifolds
TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and
More informationData sheet ECC 12 and 22
Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationPressure Independent Control Valves. The Future of Energy Saving
Pressure Independent Control Valves The Future of Energy Saving Pressure Independent Control Valves In modern uilding Services projects, the desire for energy efficiency is a primary consideration for
More informationARI-ASTRA / ASTRA Plus Combinend flow regulating valve
ARI-ASTRA - Free of maintenance combinend flow regulating valve - soft sealed (to 120 C) ARI-ASTRA Plus - Free of maintenance combinend flow regulating valve (to 175 C resp. 350 C) ARI-ASTRA / ASTRA Plus
More informationHose and Tube Fittings Series 1-3
Embracing Challenge Hose and Tube Fittings Series 1-3 out of plastics PP, PVDF, PTFE Series 1 Special Features Corrosion resistant Gas tight Easy to handle Different connection threads Application Hose
More informationBROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas
BROEN UNIFLEX Fittings FOR BURNIN ASES BROEN UniFlex TM Fittings for burning gases BROEN UniFlex TM Fittings for burning gases LAB Table of Contents Content Page Table of Content 2 Product Overview 3 BROEN
More informationAutomatic balancing valves ASV
Automatic balancing valves ASV ASV-P ASV-PV ASV-PV ASV-PV ASV-BD ASV-I ASV-M 15-40 15-40 50 65-100 15-50 15-50 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More informationAPI Flanged Safety Relief Valves Series 526 CATALOG
API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes
More informationAutomatic Bypass Control AVDO
Application AVDO is a self-acting constant flow control primarily used either to maintain minimum flow rates through e.g. a low-capacity gas boiler or to control the differential pressure in a central
More informationAURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM
UROR 1030 ND 1040 Series SUCTION DIFFUSERS, COMINTION ND TRIPLE DUTY VLVES WWW.URORPUMP.COM UROR 1030 ND 1040 Series Suction Diffusers, Combination and Triple Duty Valves Designed for Direct Mounting on
More informationBRASS FITTINGS FOR THREADED PIPES
03/14 BRASS FITTINGS GENERAL FEATURES The brass fittings for threaded pipes are used as junctions for pipelines with threaded connection UNI ISO 228/1. The thread dimensions are subdivided in various types
More informationMFP14, MFP14S and MFP14SS Automatic Pumps
Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It
More informationPilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)
OPTIONS: USE: AVAILABLE MODELS: Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) DESCRIPTION The ADCA PRV47 pilot operated pressure reducing valves are designed for use on steam,
More informationDN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing
Technical data sheet R5.. Characterized control valves, 3-way, with external thread for open and closed cold and warm water systems for modulating control on the water side of air-handling and heating
More informationSTABITHERM INSTALLATION & SERVICE BOOKLET
STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationVAD. Variable Area Desuperheaters
Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated
More informationPRESSURE REDUCING VALVES
0E0-GB PRESSURE REDUCING VAVES MAIN FEATURES The pressure reducing valve is able, by varying its pressure drops, to hold the downstream pressure of the fluid at a constant level against changes in the
More informationType 3353 Angle Seat Valve
Type 3353 Angle Seat Valve Application On/off valve with pneumatic piston actuator Nominal size DN 15 to 50 (NPS ½ to 2) Nominal pressure PN Temperature range 10 to 180 C Globe valve with an angle seat
More informationVariable Area Flowmeters
www.swagelok.com Variable Area Flowmeters G Series and M Series Glass and metal (armored) tube models, including miniature armored model Highly accurate measurement with individually calibrated scales
More informationSPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED
SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED Domestic and Non-Domestic Meter Regulators G940/G941 - Domestic Meter Regulator Domestic regulator offering high performance in a compact unit. Sizes:
More informationPRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
More informationInstructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version
instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory
More informationBritish Standard Underground Hydrant Range
British Standard Underground Hydrant Range 2 THE NEW AVK BRITISH STANDARD HYDRANT RANGE AVK are the renowned market leading innovators, manufacturers and suppliers of BS 750 fire hydrants into the UK,
More informationVAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationCALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB
Compact automatic flow rate regulator with polymer cartridge 127 series REGISTERED BS EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01166/09 GB Function The AUTOFLOW devices
More informationSISTO-16TWA/HWA/DLU. Type Series Booklet
Diaphragm Valve SISTO-16TWA/HWA/DLU PN16 DN 15-200 Maintenance-free Flanged Ends Type Series Booklet Legal information/copyright Type Series Booklet SISTO-16TWA/HWA/DLU All rights reserved. The contents
More informationTYPE APPROVAL CERTIFICATE
DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. P-14862 This is to certify that the Pipe System with Couplings with type designation(s) Megapress with SC-contour Issued to Viega GmbH & Co.
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More informationRAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID
More informationThermostatic element RAVV for 2-way valves
Description / Application RAVV is a self-acting thermostatic element which can be combined with 2-way valve bodies RAV-/8, VMT-/8 or VMA 15. RAVV is used to control temperatures in small hot water cylinders
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationPlastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
More informationHose Clamps & Fittings
All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw
More informationVe-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:
Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees
More informationMustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
More informationAutomatic control equipment for HVAC systems
Automatic control equipment for HVAC systems Products for domestic and industrial installations In buildings, the main aim of the installations is to guarantee and maintain a comfortable ambient. Watts
More informationAIR LINE VALVES AND GAUGES
AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand
More informationVALVES FOR REFRIGERATING SYSTEMS
VALVES FOR REFRIGERATING SYSTEMS FROM QUALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel Quality Range of Products is
More informationkymanual or Automatic - it s your Choice
. kymanual or Automatic - it s your Choice ky LKB Automatic or Manual Butterfly Valve Application LKB is a sanitary automatically or manually operated butterfly valve for use in stainless steel pipe systems.
More informationInstallation and Commissioning Manual Solar Stations FlowCon Max Evolution II
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification
More informationAIR-AIR PRESSURE MULTIPLIER (BOOSTER)
AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally
More informationTypical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More information08003-1 WATER SERVICE 2
08003_Mar08_2011.pdf Page 1 of 7 INDEX Page 08003-1 WATER SERVICE 2 1.1 Pipe 2 1.1.1 Copper 2 1.1.2 Polyethylene 2 1.2 Valves and Fittings 2 1.2.1 Main Stops 3 1.2.2 Curb Stops 3 1.2.3 Curb Box 3 1.2.4
More informationIntegrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U
Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application Integrated valves, type RA-N (013G1382) and RA- U (013G1383), with built-in presetting are designed for
More informationFlow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
More information3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
More informationThermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
More information2 in1 SOL ARTUBE SIMPLE. FLEXIBLE. FAST. SPECIFICALLY TO BE USED TO INSTALL FLOW & RETURN PIPES FROM SOLAR PANEL TO STORAGE TANK
2 in1 SOL ARTUBE SIMPLE. FLEXIBLE. FAST. Flexible stainless steel pipe Solar UV resistant protective sheath Break joint for easy separation Integrated two-core sensor cable Closed cell elastomeric foam
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationSeated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The
More informationball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
More informationOPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
More informationInstallation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:
More informationVPS Series Static Balancing Valve
VPS Series Static Balancing Valve VPS Static Balancing Valve The Static Balancing Valve is also called double regulating valve. Primarily used in injection or other circuits requiring a double regulating
More informationCommercial Gas Cooking Thermostats
BJWA Series Commercial Gas Thermostat A223 Commercial Gas Cooking Thermostats Designed specifically for heavy-duty commercial oven and griddle applications Hi-Temp thermostat with steel bulb and capillary
More informationModel F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description
Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed
More informationred-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
More informationHow To Use A Corona Mdi 110
CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output
More informationSelf-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F
Self-operated Temperature Regulators Type 1 to Type 9 PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F Edition April 2012 Information Sheet T 2010 EN Self-operated
More informationStop valve with soft seal. Free of maintenance stop valve - soft sealed (to 120 C) ARI-EURO-WEDI - Straight through with flanges ARI-EURO-WEDI
ARI-EURO-WEDI Stop valve with soft seal Free of maintenance stop valve - soft sealed (to 120 C) ARI-EURO-WEDI - Fig. 070 Page 2 ARI-EURO-WEDI - Fig. 071 Page 2 ARI-EURO-WEDI - Hood valve Fig. 070 Fig.
More informationOPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
More informationSize : Ends : Min Temperature : Max Temperature : Materials : Cast iron body
Size : Ends : Min Temperature : Max Temperature : DN 32/40 to DN 1000 Between flanges GN10/16, ASA150 up to DN600-10 C + 110 C ( 130 C temporarily ) Max Pressure : 16 Bars up to DN300 Specifications :
More information4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves
1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire
More informationValve systems Base plates, according to standard ISO 5599-1. Brochure
ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure
More informationMikrotherm. Manual radiator valves. To be precise.
Manual radiator valves To be precise. Description HEIMEIER Mikrotherm manual radiator valves made of corrosion-resistant gunmetal, with white plastic hand wheel cap, tight-packed with protection film.
More informationSIZING AND CAPACITIES OF GAS PIPING
APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following
More informationToroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationAUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS
01B101-GB AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS MAIN FEATURES ADVANTAGE OF BUILT-IN MANUAL DISCHARGE - Provision for controlling operation of the automatic discharge
More informationCOUNTERBALANCE VALVES
COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load
More informationSeries 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve
Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications
More informationVXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
More informationStainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
More informationGeberit Mapress Catalogue 2008 / 2009. Valid from 1 April 2008
Geberit Mapress Catalogue 2008 / 2009 Vali from 1 April 2008 Mapress Stainless Steel Page 3 Mapress CrNi Steel Page 23 Mapress Stainless Steel silicone-free Page 25 Mapress Stainless Steel Gas Page 39
More informationSubmersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
More informationVdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More informationORLANDO srl. M P R 50 025 OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar
Chiavari (Ge) - Italia Tel.: Italia + 0185 + 38.50.10 Fax: Italia + 0185 + 38.50.11 e-mail: orlando@orlando.it Http://www.orlando.it M R 50...: Radial pressure gauge ø 50 ( available scale in bar: 4, 6,10,12,16
More informationISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24
Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical
More informationFluxi 2000/TZ Turbine Gas Meter
Gas Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas.
More information