Switches & Pilot Devices
|
|
- Joan Walton
- 7 years ago
- Views:
Transcription
1 ø0mm - Series Signaling Lights Key features: Wide variety of heavy-duty oiltight cam switches Operators available up to positions Switches made with a double circuit contact block Contact blocks rated 00V, 0A Ideal for ammeter/voltmeter applications Built to order not available in subcomponents UL listed and A certified Type, UL Listed File No. E Series Heavy Duty Cam Switches A Certified File No. LR Contact Ratings Rated Thermal Current 0A AC Break Current 0V/A 0V/A 0V/A 00V/A Resistive Break Current V/A 0V/A 0V/A 0V/0.A DC Break Current V/A 0V/.A 0V/0.A 0V/0.0A Inductive Make Current (A) Rated amperage x. Electrical Life 00,000 operations minimum (at full rated load) Mechanical Life,000,000 (at no load) Series Operator Series Style Cam Angle Maximum Contacts To Be Mounted Handle Styles 0º Up to ANO º Up to 0º Up to to 0 decks; Up to 0 contacts YB, SB, PB, FB 0º Up to ANK 0º Up to º Up to 0º Up to to 0 decks; Up to 0 contacts HB or standard key 0º Up to 0º Up to UQO º Up to 0º Up to 0º Up to to 0 decks; Up to 0 contacts YB, SB, PB, FB UQM º Spring return Only. Do not use spring return (SR) for more than six contacts.. Two identical keys come with ANK unit. Specify H for handle key option.. For handle styles, see page. to decks; Up to contacts YB, SB, PB, FB 0
2 ø0mm - Series Series ANO = Standard Cam Switch (0mm) ANK = Key Cam Switch (0mm) UQO = Cam Switch ( hole mounting) UQM = Spring Return Cam Switch ( hole mounting) Number of Levels (Decks) through 0 Note: One level contains two independent contacts.* Number of s through Angle = 0 ( position max) = ( position max) = 0 ( position max) = 0 ( position max) Illuminated Selector Switches (Assembled) Assembled Illuminated Selector Switches ANO ( ) SB C0. *Contact blocks may contain two independent contacts, (a four position switch with four independent contacts only requires two contact blocks).. *Caution: switches with 0 or more of rotation may require separate blocks for each contact due to cam overlapping.. Key retainable in every º position (, 0, 0,, 0,, 0). Contact Arrangement. For standard contact arrangements, use designations on page.. For custom contact arrangements, omit contact arrangement designation and complete the blank order form on page. Handle YB = Knob, Small SB = Lever, Small PB = Lever, Large FB = Knob, Large HB = Handle Key (ANK only) Blank = Standard Key (ANK only) Spring Return Action Blank: Maintained RO = Spring return from left (, or position, only) OR = Spring return from right (, or position, only) RR = Return from right and left ( pos, only) Signaling Lights 00--IDEC () USA & Canada
3 ø0mm - Series Standard Arrangements Contact Arrangements Terminal Numbers Numbers Signaling Lights C-00 C-00 C-0 C-00 C-00 C-00 C-00 C-00 C-00 C-00 C-00 C-0 C-00 C-00 C-00 C-0 C C-00 C C-00 C-00 C
4 ø0mm - Series Contact Arrangements continued Ammeter Switching C-0 C-00 C-00 C-00 R S T O R S T CT 0 E Voltmeter Switching C-0 C-00 R S T E PT ø-w C-00 C-00 R S T E PT 0 ø-w A V V R S T O R S T A CT 0 E R S T O R S T A 0 0 CT E R S T O RS ST TR PT 0 V Signaling Lights 00--IDEC () USA & Canada
5 ø0mm - Series Signaling Lights Series ANO ANK UQO UQM *Note: One Deck can drive two independent contacts. Number of s *Number of Decks Specify Qty =,,,,,,,,, or 0 Unit Angle s 0 only, 0,, ANO 0 or only or ANK* UQO 0, or 0 or 0,, 0, 0,, or UQM only only * ANK keys only remove at. Contact Arrangement Table Cams Deck Deck Deck Deck Deck Deck Deck Deck Deck Deck 0 Terminal Numbers and and and and and 0 and and and and and 0 and and and and and 0 and and and and and 0 Order Form (Custom Contact Arrangement) Angle = 0º = º = 0º = 0º ( ) Spring Return Blank = Maintained RO = Spring return from left ( or position, º) OR = Spring return from right ( or position, º) RR = Return from right and left ( position, º) Handle UQM is available in spring-return version only. ANO, UQO, UQM: YB = Knob, Small SB = Lever, Small PB = Lever, Large FB = Knob, Large ANK: HB = Handle Key (option) Blank = Standard Key For handle styles, see page. 0 To specify non-standard arrangements (designation not on preceding pages), fill in this table using the following symbols. X = Closed contact (break before make) O = Open contact X X = Overlapping contact (remain on when switch is moved between two positions) Specifying Nameplate (Optional) 0º º 0 0º 0º Specifying Legends If no engraving information is provided, a blank nameplate will be supplied.
6 ø0mm - Series Replacement Handles Accessories Series Part Number H-YB H-SB H-PB H-FB H-HB Dimensions 0. D x. H 0. D x. H. D x. H. D x Ø. 0. D x. H Applicable Models ANO, UQO, UQM ANK Replacement Nameplates Size & Shape q. (mm) Black Aluminum Part Number CQ CQM CQN Applicable Models UQO UQM ANO, ANK. Extra cost for engraving, / min. letter height, Legends maximum ten characters.. Blank nameplates are supplied with all cam switches (they need not be ordered separately). Wiring Clips Part Number CJ- CJ- Replacement Keys Part Number K0 Contact Block Jumpers Between decks Same deck Description Pair of keys (#0) Signaling Lights 00--IDEC () USA & Canada
7 ø0mm - Series ANO M. Terminal Screw Dimensions/Terminal Arrangements/Mounting Holes Panel Thickness 0. to 0 (S Handle) Terminal Arrangement N+ * 0. Signaling Lights ANK * Spring Return: Maintained: M. Terminal Screw Panel Thickness 0. to 0 UQO N+ * * Spring Return: Maintained:. Panel Thickness.0 max. -M Screw Mounting Holes R0. max (Y Handle) M. Terminal Screw N+ * * Spring Return: Maintained: ø0. 0 (ANO/ANK) UQM. Panel Thickness.0 max. -M Screw UQO UQM -ø. M. Terminal Screw N+ 0 (P Handle) 0 ø
Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
More informationTerminal Blocks. BA Series. Specifications. Model BA111T BA211T BA311T BA411S
BA Series BA Series Specifications Key features: Self-contained: end plates are not required Rugged heavy-duty construction Current capacities up to 40A 3-pole units available as 1 piece (no endplates
More information9 Control Equipment. Control Button Series 8082
9 Control Equipment Control Button 01706E00 contact elements enable contact blocks to be combined easily; using an actuator in the 8602 series, regardless of the type of actuator, up to 4 contact elements
More informationVOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
More informationSBM Control & Transfer Switch Rotary switches for circuit breaker control, motor control or instrument transfer. Features and Benefits Applications
SBM Control & Transfer Switch Rotary switches for circuit breaker control, motor control or instrument transfer. Features and Benefits Compact design Up to 10 stages (20 contacts) Double surface cams (one
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More informationControl and Signaling Units
Control and Signaling Table of Contents Page Specifications... 3 Constructions Characterisitics... 3 Ordering Guide... 4 Pushbutton... 5 Double Pushbutton... 6 Emergency (Mushroom Head)... 6 Selector...
More informationRelays. Relays. RH Series. RH Series General Purpose Midget Relays. Specifications
RH Series RH Series General Purpose Midget Key features of the RH series include: Compact midget size saves space High switching capacity (A) Choice of blade or PCB style terminals Relay options include
More informationTerminal Blocks. BNH/BN Series. Specifications. Model BNH10W BNH15MW BNH15LW BNH30W
BNH/BN UL Recognized File No. E78117 CSA Certified File No. LR64803 BNH/BN Series Specifications Key features: Touch-down terminals with spring-loaded captive screws Jumpers available up to 50A model Fuse
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationEMF/EMR. Holder/Release Devices with Integral Door Closers
EMF/EMR Holder/Release Devices with Integral Door Closers EMR TECHNICAL DETAILS DORMA EMR SERIESHOLDER/RELEASE DEVICE The DORMA EMR Series holder/ release device incorporates a photoelectric detector and
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationCommunication & Networking
Overview (Actuator Sensor Interface) s MicroSmart Pentra Master Module Pg. 247 73W 145W Pg. 251 SX5A Safety Monitor Pg. 292 Flat Cable Connector SX5A Safety Communication Terminal (Safety Slave) Pg. 292
More informationA sophisticated design for a demanding field. prima series
A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally
More informationPower Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationTF2 Series Miniature Snap-acting Switches
Miniature Snapacting Switches Features/Benefits Broad range of operating forces Ratings up to 10 AMPS Wide variety of actuator styles Quick connect terminations Typical Applications Motor controls Thermostatics
More informationSwitches & Pilot Devices
Key features: 21/4 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action
More informationRelays & Sockets. RH Series Compact Power Relays. Part Number Selection
RH Key features SPDT through PDT, 0A contacts Compact power type relays Miniature power relays with a large capacity 0A contact capacity Compact size saves space Contact SPDT DPDT PDT PDT RH Series Compact
More informationTHE ADVANTAGES ARE YOURS
THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many
More informationClass 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015
Hubbell Industrial Controls, Inc. Class 58 Drum Controller Catalog & Price List November 205, Replaces Jan 205 Class 58 Drum Controllers start, stop and change the speed and/or rotating direction of reversible
More informationHolder/Release Devices with Integral Door Closers DORMA EMF/ EMR
Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR DORMA EMR Holder/Release Device with Integral Detector The DORMA EMR Series holder/release device incorporates a photoelectric detector
More informationType NT and Type ZWM Terminal Blocks
Type NT and Type ZWM Terminal Blocks Side view of closed Sliding Link Block Sliding Link Block with white marker strip Unit-pole construction Sliding link to permit testing without disturbing wiring High
More informationCHAPTER 5 PARTS. This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation.
CHAPTER 5 PARTS PARTS BY PICTORIAL This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation. NOTE: The following is a breakdown description of the
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationwww.jameco.com 1-800-831-4242
Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. Interactive Catalog Replaces Catalog Pages Honeywell Sensing and Control
More informationNEW! Typical Applications. Motor controls Thermostatics Portable tools Air Conditioner. Materials
TF2 Series Miniature Snapacting Switches NEW! Features/Benefits Broad range of operating forces Ratings up to 10 AMPS Wide variety of actuator styles Quick connect terminations Typical Applications Motor
More informationB. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems.
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes wall switches; wall dimmers; receptacles; multioutlet assembly; and device plates and decorative box covers. B. Related
More informationFire Alarm System Plans Review Checklist Property location Date of Review
Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationSolid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In
More information951SX LONER Temperature Controlled Soldering Station
Instructions for 951SX LONER Temperature Controlled Soldering Station UL LISTED made in U S A COMPLIES WITH DOD-STD-2000-1B, MIL-STD-2000A and ESD SPEC. DOD-STD 1868, DOD-HDBK-263 Specifications for Model
More information12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
More informationOperation Manual. Trans-Flo
Operation Manual Trans-Flo The TRANS-FLO SYSTEM is a standard-output ballast that can be dimmed on most common theatrical SCR dimming systems. The modular design of the TRANS-FLO SYSTEM streamlines set
More informationManual Switches Series 2 Pushbutton Switches and Indicators
BARRIER MOUNT Display screen (page 115) Mounting barrier (next page) Housing (next page) FEATURES Easy-to-assemble modules provide thousands of display/control combinations Up to 4 incandescent lamps 1,
More informationOperating Instructions. Room temperature controller
Operating Instructions 1. Area of application The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc. Safety instructions
More informationMR221-MR222 Heavy Duty Geared Limit Switches, CE Approved
MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved MICRONOR automation components Product MICRONOR MR221 and MR222 series Heavy Duty Geared Limit Switches are for use in the most demanding industrial
More informationPilot and Signaling Devices. Section 9. www.geindustrial.com Control Catalog 9-1
The GE push button offering includes a complete line of control units and stations in both full size (30 mm) push buttons and in smaller size (22 mm) devices which are designed to be used in numerous types
More informationSZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control
Power Relay FEATURES Small package design ARC barrier equipped Silver Cadium Oxide contact High dielectric strength (,800 Vac) High reliability and long life Ultra-high sensitivity with quick response
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationSECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
More informationTerminal Blocks. Switching & Controls. www.idec.com/terminalblocks. Selection Guides... 900
Switching & Controls Selection Guides... 900 General Purpose... 901 BN/BNH Modular Terminal & Fuse Blocks... 901 BN High Current Power Blocks... 905 BA One Piece Terminal/Fuse Blocks & Small Current Power
More informationSpecifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS
Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant
More informationSHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM
SHIFT INTERLOCK SYSTEM The shift lock system is designed to ensure the proper operation of the automatic transmission. The driver must depress the brake pedal in order to move the gear selector from Park
More informationSignaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)
Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationHuwilift DUO, Huwilift DUO Forte Seite 4 3. Huwilift MAXI. Huwilift MAXI UP. Huwilift Senso, Huwilift E-Senso Page 4 17
INDEX Lifters Huwilift DUO, Huwilift DUO Forte Seite 4 3 Classic solution for lift-up flaps. Huwilift MAXI Page 4 7 Quickly installed for a gentle lift. Huwilift MAXI UP Page 4 13 Lifts and lowers chest
More informationPHA 2000 PHB 3000 EXIT PAD
PHA 2000 PHB 000 EXIT PAD Panic Hardware in Contur Design PHA 2000 PHB 000 EXIT PAD THE MODULAR PANIC HARDWARE-SSTEM IN CONTUR DESIGN Prior knowledge of how to open the escape door is not expected. DANGER
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationAC SERIES-C TYPE DUAL CONNECTORS JACK/XLR
AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 )
More informationProduct Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationPA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.
Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor
More informationLEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34
LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationRotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch
echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data
More informationResistors in Series and Parallel Circuits
69 Resistors in Series and Parallel Circuits E&M: Series and parallel circuits Equipment List DataStudio file: Not Required Qty s Part Numbers 1 C/DC Electronics Lab EM-8656 2 D cell 1.5 volt Introduction
More informationSpeed Control Relays SX2
SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................
More informationPhysics 3330 Experiment #2 Fall 1999. DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.
Physics 3330 Experiment #2 Fall 1999 DC techniques, dividers, and bridges Purpose You will gain a familiarity with the circuit board and work with a variety of DC techniques, including voltage dividers,
More informationQ SERIES Ø14mm (.551") Panel Mount LED Indicators Distinctive features and specification
Distinctive features and specification Q14_VOY1609R2US Features 14mm panel mounting LED indicator 10mm colored diffused epoxy lens or 10mm water clear super bright LEDs Plated brass bezel finished in bright
More informationSECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated
More informationType Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1
Power PCB Relay G2R Creepage distance of 8.0 mm (0.31) min. between coil and contact. Dual-winding latching type available. Plug-in and quick-connect terminals available. High sensitivity (360 mw) and
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More information951SX LONER Temperature Controlled Soldering Station
951SX LONER Temperature Controlled Soldering Station COMPLIES WITH MIL-S-45743E, MIL-STD-2000-1B, WS6536E AND ESD SPEC, DOD-STD-1686, DOD-HDBK-263 UL listed made in U S A Instruction manual Specifications
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationScraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
More informationBRITISH STYLE SEMICONDUCTOR PROTECTION FUSES
The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions
More information08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
More informationRose Door Handles. We take the worry out of protecting what s valuable to you. Lockwood: no worries. www.lockweb.com.au
Rose Door Handles We take the worry out of protecting what s valuable to you. Lockwood: no worries www.lockweb.com.au Contents Robert Watson Series 20 Symphony Series 1420 Symphony Series 1360 Series Door
More informationSFERA. NEw. 2 wire. audio ViDEO PUSHBUTTON PANELS
SFERA NEw 2 wire audio ViDEO PUSHBUTTON PANELS new SFERA TWO personalities FOR ONE SINGLE electronic HEART The QR Code provides direct access to multimedia contents. The service is very easy to use, and
More informationTS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationUNIVERSITY OF WATERLOO ELECTRICAL & COMPUTER ENGINEERING DEPARTMENT ME269 ELECTROMECHANICAL DEVICES AND POWER PROCESSING.
UNIVERSITY OF WATERLOO ELECTRICAL & COMPUTER ENGINEERING DEPARTMENT ME269 ELECTROMECHANICAL DEVICES AND POWER PROCESSING. Group # First Name Last Name UserID @uwaterloo.ca Experiment #3: DIRECT CURRENT
More informationwww.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
More informationTP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12
Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Cleaveland/Price Type TP-C2 Motor Operator
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationAVENTOS HF Narrow aluminum door application
AVENTOS HF Narrow aluminum door application Lift mechanism set Lift mechanism (qty ) #7 x 35 mm (-3/8 ) wood screw (qty 0) Power factor 85 30 ( lift mechanism req.) 0F00.N5 3 470 0F00.N5 47 880 0F500.N5
More informationVAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.
Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.
More informationPower Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
More informationDegree Key System. Technical Manual
Degree Key System Technical Manual Copyright 03-04, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission
More informationPASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE
MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationSwitches and Indicators. Swisstac
Switches and Indicators Switches and Indicators Index Series Description Page 583 Product Assembly Page 584 Mounting Instruction Page 585 Product Range - pushbuttons for standard mounting - pushbuttons
More informationModel: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationSKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
More informationCAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual
Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual
More informationKit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
More informationGeneral Informations 2 Technical data 3 Basic designs 4-8
Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More information