Comtronic Standard Sensors
|
|
- Felicity Barnett
- 7 years ago
- Views:
Transcription
1 oiti Comtronic Standard Sensors This universal sensor is used for all compact cylinders, inch or metric. Sold separately. Not attached to the cylinder. on page 5 Sensors Sensors Sensors Sensors Sensors Sensors Sensors Compact Standard Limit Sensors (shown with Quick Disconnect Option) WSKLPS 3 Prong Plug #WSKLP, #WSCLP, #WSKLPS, #WSCLPS 31,1 M8x1 (Male Connection) 0,15 Meters WSCLPS LED Indicator Low cost and Compact size Dual LED indicators for power and signal Circuit protection/surge and polarity High-flex robotic grade cable with 4.8mm (3/16") bend radius. 105 strand primaries. CE compliant / IP67 and NEMA 6P rated 100% solid state device for maximum life 3 cord options Dimensional Information Must specify K (sinking) or C (sourcing) when ordering See page 5 for definitions and more information 14,0 Dual LED Indicators Locking Screw 14,2 1 or 3 Meters (3 or 10 Feet) 3,3 Dia. - Specify K or C WS L Part No. WSCL3 Sourcing output with 3 meter cable. Optional Quick Disconnect Sensor Cable with threaded, sealed connectors - Specify K or C WS LP 6,0 WS LPS Sensing Face S denotes shorter length cable WS L3 3 denotes 3 meter cable PartNo. SensorType (W niri g daig armsand Qucik de nif ns on page 5) 1 M eetr 3 M eet r D siconnect W SKL W SKLP * NPN W SKL3 W SKLPS * W SCL W SCLP * PNP W SCL3 W SCLPS * *Mating 3 Socket Receptacle available, part #. Parameters voltage Consumption Switching Voltage Drop Frequency Switch Logic LED Function Cord Types Specifications C ompact Standard Limit Sensors On Off Green Red Circuit Protection Environmental Certifications Wire Type Sinking Sourcing Material Color Code Shock Resistance Vibration Strength 3 Socket Receptacle For use with: #WSKLP, #WSCLP, #WSKLPS, #WSCLPS, #HSK, #HSC, #, # Sold Separately 3 Meters (10 feet) N PN ( sinking) (sourcing) WSKL, WSKL3, WSCL, WSCL3, WSKLP, WSKLPS WSCLP, WSCLPS 5-24 VDC 16mA (24V) 7mA (24V) Sinking, 100 ma Max 14mA (24V) 7mA (24V) 1.5 V 100mA 1 KHz Max Power On Switch Active 0 C to 70 C Sourcing, Reverse Polarity / Surge Absorber IEC standard IP67, NEMA 6P High flex, 24 AWG / 105 strand primary Black Zinc diecast 30G Max 9G Max 32,1 Silver 9,5 Female Connection M8x1 Nut 2 1/00
2 Comtronic Husky Sensors This universal sensor is used for all compact cylinders, inch or metric. Sold separately. Not attached to the cylinder. Compact Husky Limit Sensors on page 5 HSK HSC Rugged design for harsh environments Weld field interference immunity Extra secure mount with socket head cap screw Threaded connector on housing Impact resistant LED indicator Reverse polarity protection CE compliant / IP67 rated 200mA switching current Better suited for large Compact cylinders Part No. Sensor Type Cord Type (Wiring diagrams and definitions on page 5) Quick Disconnect HSK N PN ( sinking) * HSC ( sourcing) * C omtronic H usky sensors are n ot offered with flying leads. *Mating 3 Socket Receptacle available, part #. Dimensional Information Must specify K (sinking) or C (sourcing) when ordering See page 5 for definitions and more information Husky Sensors are manufactured with a quick disconnect option. See below for the mating 3 meter socket receptacle. 15 4,2 Weld Field Data Rated Field Strength Hn [ ka/m] 1. 2 Assured Field Strength Ha [ ka/m] 2 M aximum Noise Field Strength [ ka/m] 200 N oise Field Frequency [ Hz] Differential Travel H [% of Hn] 45 Ambient Range Ta [ C] Drift Locking Socket Head Cap Screw (Allen key included) 24 Sensing Face [% of Hn] ,5 LED indicators 11 13,9 M8x1 (3 Prong Male Connection) 18 HS Specify K or C Specifications C ompact usky Parameters Limit Sensors Part Number voltage Consumption Switching Voltage Drop On Off H N PN ( sinking) (sourcing) HSK VDC 25mA (24V) 80uA (24V) 200 ma Max HSC 3.1 V 200mA Response Time 50mS Frequency 1Hz 10Hz Switch Logic LED Function Circuit Protection Conditional Short Circuit Red Sinking, Switch Active -25 C to 70 C Reverse Polarity 100A Environmental Certifications IP67 Wire Type Material Color Code Weld Field Immunity NA Sourcing, Anodized Aluminum Black Standard Silver 3 Meter Socket Receptacle 3 Socket Receptacle For use with: #WSKLP, #WSCLP, #WSKLPS, #WSCLPS, #HSK, #HSC, #, # 3 Meters (10 feet) 32,1 9,5 Female Connection M8x1 Nut Sold Separately 3
3 Comtronic Round Sensors Two of these sensors are included on B and C series electric cylinders only. Please specify sinking or sourcing output. Compact Round Limit Sensors (shown with Quick Disconnect Option) Low cost and Compact size Single LED indicator for signal Circuit protection/surge and polarity Parameters Part Number voltage Consumption Switching Voltage Drop Frequency Switch Logic C ompact Round Limit Sensors N PN sinking) Specifications Parameters C ompact Round Limit Sensors ( ( sourcing) N PN ( sinking) (sourcing) Part Number 5-24 VDC Circuit Protection 7mA (24V) Max 9mA (24V) Max Environmental Certifications Wire Typ Materia Color Cod 50 ma Max e. 5 V 25mA 1.2 V 25mA l 1 KHz Max e Sinking Sourcing L ED Function R ED (Switch Active) GREEN (Switch Active) Dimensional Information Must specify K (sinking) or C (sourcing) when ordering See page 5 for definitions and more information 2,5 4,5 4 Dia 31,1 M8x1 (Male Connection) -20 C to 70 C 3 Meter Socket Receptacle 3 Socket Receptacle For use with: #WSKLP, #WSCLP, #WSKLPS, #WSCLPS, #HSK, #HSC, #, # 3 Meters (10 feet) High-flex robotic grade cable with 4.8mm (3/16") bend radius. 105 strand primaries. CE compliant / IP67 and NEMA 6P rated 0,21 Meters 32,1 LED Indicator 9,5 Female Connection 25,5 M2,5 Screw M8x1 Nut Shock Resistance Vibration Strength Part No. Reverse Polarity Surge Suppression IP67, NEMA 6P Black Polyurethane Jacket, PVC Insulation Plastic Black 50G Max 9G Max on page 5 Sensor Type (Wiring diagrams and definitions on page 5) Cord Type Quick Disconnect N PN ( sinking) * ( sourcing) * *Mating 3 Socket Receptacle available, part #. WS LRPS Specify K or C Part No. Sinking output with quick disconnect Sensors Sensors Sensors Sensors Sensors Sensors Sensors Sold Separately 1/00 4
4 Comtronic Sensors below Wiring Diagrams and Definitions for units with flying leads NPN Output Sinking (K) +5 to +24 VDC Load Ideal for complex controls utilizing multiple power supplies. A sinking output sensor completes a circuit by connecting the load to ground. Sinking output sensors in a sequence can have different supply voltages. The ground is their common factor. Descriptions Sensor Descriptions Code Description W Metric H Husky R Round SK Sinking Output SC Sourcing Output P Quick Disconnect with.46 Meter Cable (18") P S Quick Disconnect with.15 Meter Cable (6") L Low Voltage 3 3 Meter Cable 3 Meter Cable with 3 Socket Receptacle Precautions Examples: PNP Output Sourcing (C) +5 to +24 VDC Ideal for single power supply applications. Load A sourcing output sensor completes a circuit by connecting the load to the supply current. All sourcing output sensors must have the same supply voltage. W = Metric SK = Sinking Output L = Low Voltage R = Round PS = Quick Disconnect with 6" Meter Cable Sensors are magnetically activated and will not function without the magnetic piston. Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and magnetic characteristics are not guaranteed as the maximum limits are approached nor will the device necessarily operate at the absolute maximum rating. Presence of external magnetic / electromagnetic fields may interfere with the operation of Compact Limit sensors only. Use the Husky Limit sensor in the presence of an external electromagnetic field. WSCLP W = Metric SC = Sourcing Output L = Low Voltage P = Quick Disconnect with 18" Meter Cable Sensors Sensors Sensors Sensors Sensors Sensors Sensors 1/00 5
5 When your design goal is: Absolute size and weight efficiency Maximum component life Smooth-running, low friction and fast-cycling performance look to Compact Air Products for maximum versatility and adaptability to your design needs. Just as when we first opened our doors, our objective continues to be benchmark-level performance and reliability. Compact Air Products is committed to answering your needs quickly and costeffectively. Since Compact cylinders are assembled to order from standard components, you'll enjoy all the benefits of custom options and the ready availability of a standard product. We can deliver cylinders configured from standard components in less than three working days, furnish quotes on modified products in twenty-four hours and deliver modified products in an average of ten working days. Tell us about your needs. We'll answer with a rapid solution tailored to meet them. We're ready to answer your call. All products manufactured by Compact Air Products, Inc., are covered under a growing number of US and international patents. Numerous other patents are pending. Compact, Husky, Comtronic, Tuf-Coat, Snap-Cap, Clean-Act and World Class are all registered trademarks of Compact Air Products, Inc. Compact Air Products, Inc. P.O. Box 499 Westminster, SC Tel: Fax: mkt@compactair.com (catalog information) techsales@compactair.com (product information) Website: Sensor with receptacle Warranty All of our products are warranted against defects in workmanship and materials for a period of three years from the date of shipment. Compact Air s sole liability under this warranty is expressly limited to the correction or replacement of the product. Products under this warranty must be returned prepaid with a Returned Goods Authorization number. Warranty does not cover ordinary wear, tear, abuse, misuse, improper storage, abnormal conditions of temperature, overloading, or improper lubricant. No warranty is made with respect to items altered, damaged in shipment, misapplied, or in contact with contaminants. Compact Air assumes no liability to any company or person for any damages, direct or indirect, to property or person. This warranty is expressly in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose.
6
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
More informationColor Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
More informationT-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationSensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
More informationLED...A70..4-..Q Series Sealed High-Intensity
LED...A70..4-..Q Series Sealed High-Intensity Area Lights High-Power Lighting for use with PresencePLUS and Other Vision Systems Features Rugged, waterproof housing, rated IEC IP68 Compact area light for
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationEE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
More informationOrdering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
More informationWORLD-BEAM QS30 Sensors
Datasheet High-Power Opposed-Mode Sensors Infared beam with high excess gain range of over 213 m (700 ft) Excellent noise immunity Excellent for applications ere high sensing power is required due to long
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationCONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationCapacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationInstructions & Safety Information Models A220-20D and A220-20L Version 2
Quick 220 Voltage Converting Power Supply Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Systems LLC PO Box 47489 Phoenix, Arizona 85068-7489 800-347-0394 602-938-6057
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationHow To Power A Schen
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
More informationMaterial: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationOperating Manual UWAPS-TINY Series
Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4
More informationSENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
More informationProximity Switches RS (Reed Switch)
Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity
More informationInstructions A622 100 Amp AC/DC Current Probe 070-8883-03
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
More informationEE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws
Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.
More informationMini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
More informationVAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.
Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationDSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationDifferential Charge Amplifier
Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic
More informationTubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationTemperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
More information1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting
Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8
More information550658 D. PARAMETER SPECIFICATION Measured Variable: Displacement
T E M P O S O N I C S L S E R I E S LH 550658 D P r o d u c t S p e c i f i c a t i o n s Temposonics L Series position sensors are available with analog outputs (voltage or current) or digital outputs
More informationSignal Manager Installation and Operation Manual
Signal Manager Installation and Operation Manual Rev.11/28/2008 Part # 26550007 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 CHAPTER 2: SYSTEM INSTALLATION... 4 HARDWARE
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationMachine Safety Switch: SI-LM40 Series Limit Switch Style
Machine Switch: SI-LM40 Series Limit Switch Style SI-LM40 Series Limit Switch Style with Flexible In-Line Actuator Positive-opening safety contacts (IEC 60947-5-1) (not dependent upon springs) Standard
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More informationUSE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2
Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance
More informationSENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
More informationMACTek Corporation. USB HART Interface. Users Manual
MACTek Corporation USB HART Interface DM01003100AA February, 2003 LIMITED WARRANTY VIATOR Interface for HART MACTek Corporation warrants this Interface and all of its component against defects in materials
More informationEmergency lighting units EM powerled
M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year
More informationLighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
More informationInductive Proximity Sensors
M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12
More informationThe table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
More informationDescription. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
More informationBOS 73K... BOS 74K...
BFB/BOS When there s no space for a photoelectric sensor, there is only one solution: user fiber optics! If there are no particular demands for toughness an ambient temperature or chemical resistance,
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationTemposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors E-Series Model ER Analog and Start/Stop Outputs SENSORS Document Part Number: 550996 Revision E Data Sheet Model ER position
More informationSmart Sensing Solutions Since 1954
Smart Sensing Solutions Since 1954 X-tremely High Speed Photoelectric Registration Sensor 800-237-0946 ttco.com 813-886-4000 Photoelectric Registration Sensor The SMARTEYE X-MARK TM is the fastest, most
More information330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal
More informationRoHS. Shock / vibration resistant. Magnetic field proof. Many variants
Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationElectric Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE
More informationCQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationOperating Instructions for Plastic Flow Meter. Model: KSK
Operating Instructions for Plastic Flow Meter Model: KSK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...
More informationHow To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
More informationFriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual
FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual Asanté Technologies, Inc. 821 Fox Lane San Jose, CA 95131 Copyright Notice Copyright 1997 by Asanté Technologies, Inc. All rights reserved. No
More informationtechnical data (according to IEC 60947-5-2)
Photoelectric sensors: Series 3#30 & 3#31 ü Complete miniature sensor series mm in rugged Crastin housings ü Shock & vibration resistant due to fully vacuum-potted electronics ü Diffuse sensors with precise
More informationMS900AC-B-LS User Information
MS900AC-B-LS User Information MS900-R-AC-B-LS systems equipped with MR900 Micro Receiver are Receive-Only. MS900-X-AC-B-LS systems equipped with MX900 Micro Transceiver will Send and Receive. The model
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationModel SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
More informationLS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationRI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationSOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
More information1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com
1080P Extender for HDMI over one CAT5 GTV-HDBT-CAT5 User Manual gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:
More informationQuick Disconnect. Wiring diagrams show quick. Male Receptacle End View Blue. disconnect pin numbers ( ) 1 Brown. Load. 4 1 Black ( ) 3 Blue ( ) Brown
Pile Driver Sensor One-piece stainless steel cylindrical housing 2-wire DC 3-wire DC 2-wire AC/DC 1. to sensing range dia. model: The Die Guy TM Rugged Solid stainless steel housing withstands abusive
More informationPA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.
Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor
More informationAUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER
FILE: IM_091-120-12E-20 Rev A., 05-06-08 INSTRUCTION MANUAL AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER R MODEL #091-120-12E-20 for ODYSSEY AGM BATTERIES CAUTION This charger is calibrated to the ODYSSEY
More informationK Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)
SureGrip TM 80PK-24 Air Temperature Probe Instruction Sheet XWWarning To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically
More informationSeries 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
More information400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
More informationTechnical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
More informationPart I - Installation
400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read
More informationSealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
More informationModel 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
More informationIntersection Preassembled 19-inch Rack
Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion
More informationUSER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these
More informationGENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control
More informationSingle Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
More informationFiber Optics and Liquid Level Sensors Line Guide
Fiber Optics and Liquid Level Sensors Line Guide Excellence, through every fiber. Honeywell Sensing and Control (S&C) offers fiber optic sensors manufactured with SERCOS (Serial Real-time Communication
More informationLevel Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
More informationHow To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
More information330505 Low Frequency Velocity Sensor
330505 Low Frequency Velocity Sensor Bently Nevada* Asset Condition Monitoring Description The Bently Nevada Low Frequency Velocity Sensor is designed to measure absolute (relative to free space) bearing
More informationHoneywell Pressure Switches Line Guide
Honeywell Pressure Line Guide Better under pressure. For years, manufacturers and operators of heavy-duty equipment have trusted Honeywell pressure and vacuum switches. They re proven under pressure, in
More informationCompact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationBroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
More informationMoxa EtherDevice Switch
Moxa EtherDevice Switch EDS-205 Hardware Installation Guide Third Edition, June 2008 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. P/N: 1802002050000 Overview The
More informationDimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.
Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine
More information2015 PRICE LIST. PRICING EFFECTIVE JULY 06, 2015 30121-63 Rev. 1.3/07-15 Supersedes Price List April 1, 2014, Rev. 1.2/02-15
2015 PRICE LIST PRICING EFFECTIVE JULY 06, 2015 30121-63 Rev. 1.3/07-15 Supersedes Price List April 1, 2014, Rev. 1.2/02-15 Subject to change without notice. Prices F.C.A. Factory Warehouse 3255 WEST STETSON
More information