1 Designation: D785 2 An American National Standard Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80, and 20 This standard is issued under the fixed designation D785; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript elon ( ) indicates an editorial change since the last revision or reapproval. This standard has been approved for use by agencies of the Department of Defense.. Scope*. This specification covers poly(vinyl chloride) (PVC) pipe made in Schedule 40, 80, and 20 sizes and pressure-rated for water (see Appendix X). Included are criteria for classifying PVC plastic pipe materials and PVC plastic pipe, a system of nomenclature for PVC plastic pipe, and requirements and test methods for materials, workmanship, dimensions, sustained pressure, burst pressure, flattening, and extrusion quality. Methods of marking are also given..2 The products covered by this specification are intended for use with the distribution of pressurized liquids only, which are chemically compatible with the piping materials. Due to inherent hazards associated with testing components and systems with compressed air or other compressed gases some manufacturers do not allow pneumatic testing of their products. Consult with specific product/component manufacturers for their specific testing procedures prior to pneumatic testing. NOTE Pressurized (compressed) air or other compressed gases contain large amounts of stored energy which present serious saftey hazards should a system fail for any reason. NOTE 2 This standard specifies dimensional, performance and test requirements for plumbing and fluid handling applications, but does not address venting of combustion gases.. The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification..4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard..5 The following safety hazards caveat pertains only to the test methods portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific precautionary statement is given in Note 9. NOTE CPVC plastic pipes, Schedules 40 and 80, which were formerly included in this specification, are now covered by Specification F44/F44M. NOTE 4 The sustained and burst pressure test requirements, and the pressure ratings in the Appendix X, are calculated from stress values obtained from tests made on pipe 4 (00 mm) and smaller. However, tests conducted on pipe as large as 24- (600-mm) diameter have shown these stress values to be valid for larger diameter PVC pipe. NOTE 5 PVC pipe made to this specification is often belled for use as line pipe. For details of the solvent cement bell, see Specification D2672 and for details of belled elastomeric joints, see Specifications D9 and D Referenced Documents 2. ASTM Standards: 2 D68 Practice for Conditioning Plastics for Testing D598 Test Method for Time-to-Failure of Plastic Pipe Under Constant Internal Pressure D599 Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings D600 Terminology for Abbreviated Terms Relating to Plastics D784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds D222 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings D252 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion D2672 Specification for Joints for IPS PVC Pipe Using Solvent Cement D287 Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials or Pressure Design Basis This specification is under the jurisdiction of ASTM Committee F7 on Plastic Piping Systems and is the direct responsibility of Subcommittee F7.25 on Vinyl Based Pipe. Current edition approved April, 202. Published May 202. Originally approved in 960. Last previous edition approved in 2006 as D DOI: 0.520/D For referenced ASTM standards, visit the ASTM website, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards volume information, refer to the standard s Document Summary page on the ASTM website. *A Summary of Changes section appears at the end of this standard. Copyright ASTM International, 00 Barr Harbor Drive, PO Box C700, West Conshohocken, PA , United States.

2 for Thermoplastic Pipe Products D9 Specification for Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals D22 Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals F42 Terminology Relating to Plastic Piping Systems F44/F44M Specification for Chlorinated Poly(Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and Federal Standard: Fed. Std. No. 2 Marking for Shipment (Civil Agencies) 2. Military Standard: MIL-STD-29 Marking for Shipment and Storage 2.4 NSF Standards: Standard No. 4 for Plastic Piping Components and Related Materials 4 Standard No. 6 for Drinking Water System Components Health Effects 4. Terminology. Definitions: Definitions are in accordance with Terminology F42 and abbreviations are in accordance with Terminology D600, unless otherwise specified. The abbreviation for poly(vinyl chloride) plastic is PVC..2 Definitions of Terms Specific to This Standard:.2. hydrostatic design stress the estimated maximum tensile stress the material is capable of withstanding continuously with a high degree of certainty that failure of the pipe will not occur. This stress is circumferential when internal hydrostatic water pressure is applied..2.2 pressure rating (PR) the estimated maximum water pressure the pipe is capable of withstanding continuously with a high degree of certainty that failure of the pipe will not occur..2. relation between dimensions, design stress, and pressure rating the following expression, commonly known as the ISO equation, 5 is used in this specification to relate dimensions, hydrostatic design stress, and pressure rating: 2S/P 5 ~D 0 /t! where: S = hydrostatic design stress, (or ), P = pressure rating, (or ), D 0 = average outside diameter, (or mm), and t = minimum wall thickness, (or mm)..2.4 standard thermoplastic pipe materials designation code the pipe materials designation code shall consist of the abbreviation PVC for the type of plastic, followed by the ASTM type and grade in Arabic numerals and the design stress in units of 00 (0.7 ) with any decimal figures dropped. When the design stress code contains less than two figures, a cipher shall be used before the number. Thus a complete material code shall consist of three letters and four figures for PVC plastic pipe materials (see Section 5). Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA , dodssp.daps.dla.mil. 4 Available from NSF International, P.O. Box 040, 789 N. Dixboro Rd., Ann Arbor, MI , 5 ISO R6-960, Pipes of Plastics Materials for the Transport of Fluids (Outside Diameters and Nominal Pressures) Part, Metric Series. D Classification 4. General This specification covers PVC pipe made to and marked with one of six type/grade/design stress designations (see X.2) in Schedule 40, 80, and 20 wall sizes. 4.2 Hydrostatic Design Stresses This specification covers pipe made from PVC plastics as defined by four hydrostatic design stresses which have been developed on the basis of long-term tests (Appendix X). 5. Materials and Manufacture 5. General Poly(vinyl chloride) plastics used to make pipe meeting the requirements of this specification are categorized by means of two criteria, namely, () short-term strength tests and (2) long-term strength tests. NOTE 6 The PVC pipe intended for use in the transport of potable water should be evaluated and certified as safe for this purpose by a testing agency acceptable to the local health authority. The evaluation should be in accordance with requirements for chemical extraction, taste, and odors that are no less restrictive than those included in NSF Standard No. 4. The seal or mark of the laboratory making the evaluation should be included on the pipe. See pipe marking requirement for reclaimed water systems. 5.2 Basic Materials This specification covers pipe made from PVC plastics having certain physical and chemical properties as described in Specification D Compound The PVC compounds used for this pipe shall equal or exceed the following classes described in Specification D784; PVC 2454, or Rework Material The manufacturer shall use only his own clean rework pipe material and the pipe produced shall meet all the requirements of this specification. 6. Requirements 6. Dimensions and Tolerances: 6.. Dimensions and tolerances shall be as shown in Table and Table 2 when measured in accordance with Test Method D222. The tolerances for out-of-roundness shall apply only to pipe prior to shipment. 6.2 Sustained Pressure The pipe shall not fail, balloon, burst, or weep as defined in Test Method D598, at the test pressures given in Tables -5 when tested in accordance with Accelerated Regression Test The accelerated regression test shall be used in place of both the sustained and burst pressure tests, at the option of the manufacturer. The test shall be conducted in accordance with The pipe shall demonstrate a hydrostatic design basis projection at the h intercept that meets the hydrostatic design basis category requirement (see Tables -5 and Test Method D287) for the PVC material used in its manufacture. (Example: PVC 20 pipe must have a minimum h projection of 80 (26.40 ) and 85 % lower confidence limit (LCL). 6. Burst Pressure The minimum burst pressures for PVC plastic pipe shall be as given in Table 6, when determined in accordance with Test Method D599. NOTE 7 Times greater than 60 s may be needed to bring large size specimens to burst pressure. The test is more difficult to pass using greater pressurizing times.

3 Nominal Pipe Size Nominal Pipe Size TABLE Outside Diameters and Tolerances for PVC Plastic Pipe Schedules 40, 80, and 20, (mm) Outside Diameter 6.4 Flattening There shall be no evidence of splitting, cracking, or breaking when the pipe is tested in accordance with 8.6. Average Tolerances Maximum Out-of-Roundness (maximum minus minimum diameter) Schedule 40 sizes 2 and over; Schedule 80 sizes 8 and over Schedule 40 sizes and less; Schedule 80 sizes 6 and less; Schedule 20 sizes all (0.29) (60.0) (0.4) (.72) (60.0) (0.4) (7.4) (60.0) (0.4) (2.4) (60.0) (0.4) (26.67) (60.0) (0.5).5 (.40) (60.) (0.5) (42.6) (60.) (0.6) (48.26) (60.5) (0.6) (60.2) (60.5) (0.6) (7.02) (60.8) (0.76).500 (88.90) (60.20) (0.76) (0.60) (60.20) 0.00 (2.54) 0.00 (0.76) (4.0) (60.2) 0.00 (2.54) 0.00 (0.76) (4.0) (60.25) 0.00 (2.54) (.52) (68.28) 60.0 (60.28) 0.00 (2.54) (.78) (29.08) (60.8) 0.50 (.8) (2.29) (27.05) (60.8) 0.50 (.8) 0.00 (2.54) (2.85) (60.8) 0.50 (.8) 0.20 (.05) ( (60.8) (5.08) (406.40) (60.48) 0.20 (8.) (457.20) (60.48) 0.60 (9.4) (508.00) (60.58) (0.2) (609.60) 60.0 (60.79) (2.2)... TABLE 2 D785 2 Wall Thicknesses and Tolerances for PVC Plastic Pipe, Schedules 40, 80, and 20, A,B (mm) Wall Thickness A Schedule 40 Schedule 80 Schedule 20 Minimum Tolerance Minimum Tolerance Minimum Tolerance (.7) (+0.5) (2.4) (+0.5) (2.24) (+0.5) 0.9 (.02) (+0.5) (2.) (+0.5) 0.26 (.20) (+0.5) (2.77) (+0.5) 0.47 (.7) (+0.5) 0.70 (4.2) (+0.5) 4 0. (2.87) (+0.5) 0.54 (.9) (+0.5) 0.70 (4.2) (+0.5) 0. (.8) (+0.5) 0.79 (4.55) (+0.5) (5.08) (+0.6) (.56) (+0.5) 0.9 (4.85) (+0.58) 0.25 (5.46) (+0.66) (.68) (+0.5) (5.08) (+0.6) (5.72) (+0.68) (.9) (+0.5) 0.28 (5.54) (+0.66) (6.5) (+0.76) (5.6) (+0.6) (7.0) +0.0 (+0.84) 0.00 (7.62) (+0.9) 0.26 (5.49) (+0.66) 0.00 (7.62) (+0.9) 0.50 (8.89) (+.07) (5.74) (+0.68) 0.8 (8.08) (+0.96) 0.50 (8.89) (+.07) (6.02) (+0.7) 0.7 (8.56) (+.02) 0.47 (.0) (+.2) (6.55) +0.0 (+0.79) 0.75 (9.52) (+.4) (2.70) (+.52) (7.) (+0.86) 0.42 (0.97) (+.2) (4.27) (+.70) (8.8) (+0.99) (2.70) (+.52) 0.78 (8.24) (+2.8) (9.27) (+.2) 0.59 (5.06) (+.80) 0.84 (2.4) +0.0 (+2.56) (0.) (+.24) (7.45) (+2.08).000 (25.40) (+.05) (.0) (+.5) (9.05) (+2.29) (2.70) (+.52) 0.84 (2.4) +0.0 (+2.57) (4.27) (+.70) 0.97 (2.80) +0.2 (+2.84) (5.06) (+.80).0 (26.9) (+.5) (7.45) (+2.08).28 (0.94) (+.7) A The minimum is the lowest wall thickness of the pipe at any cross section. The maximum permitted wall thickness, at any cross section, is the minimum wall thickness plus the stated tolerance. All tolerances are on the plus side of the minimum requirement. B These dimensions conform to nominal IPS dimensions, with the exception that Schedule 20 wall thickness for pipe sizes 2 to 2 (2.5 to 87.5 mm), inclusive, are special PVC plastic pipe sizes. 6.5 Extrusion Quality The pipe shall not flake or disintegrate when tested in accordance with Test Method D252.

4 TABLE Sustained Pressure Test Conditions for Water at 7 F (2 C) for PVC Plastic Pipe, Schedule 40 Nominal Pipe Size PVC20 PVC220 PVC220 Pressure Required for Test A PVC26 PVC22 PVC A The fiber stresses used to derive these test pressures are as follows: PVC PVC PVC PVC PVC PVC D785 2 TABLE 4 Sustained Pressure Test Conditions for Water at 7 F (2 C) for PVC Plastic Pipe, Schedule 80 Nominal Pipe Size PVC20 PVC220 PVC220 Pressure Required for Test A PVC26 PVC22 PVC A The fiber stresses used to derive these test pressures are as follows: PVC PVC PVC PVC PVC PVC Workmanship, Finish, and Appearance 7. The pipe shall be homogeneous throughout and free of visible cracks, holes, foreign inclusions, or other defects. The pipe shall be as uniform as commercially practicable in color, opacity, density, and other physical properties. NOTE 8 Color and transparency or opacity should be specified in the contract or purchase order. 8. Test Methods 8. Conditioning Condition the test specimens at F (2 6 2 C) and % relative humidity for not less

5 Nominal Pipe Size TABLE 5 Sustained Pressure Test Conditions for Water at 7 F (2 C) for PVC Plastic Pipe, Schedule 20 PVC20 PVC220 PVC220 than 40 h prior to test in accordance with Procedure A of Practice D68, for those tests where conditioning is required. 8.2 Test Conditions Conduct tests in the standard laboratory atmosphere of F (2 6 2 C) and % relative humidity, unless otherwise specified in the test methods or in this specification. 8. Sampling The selection of the sample or samples of pipe shall be as agreed upon by the purchaser and seller. In case of no prior agreement, any sample selected by the testing laboratory shall be deemed adequate. 8.. Test Specimens Not less than 50 % of the test specimens required for any pressure test shall have at least a part of the marking in their central sections. The central section is that portion of pipe which is at least one pipe diameter away from an end closure. 8.4 Sustained Pressure Test Select the test specimens at random. Test individually with water at the internal pressures given in Tables -5, six specimens of pipe, each specimen at least ten times the nominal diameter in length, but not less than 0 (250 mm) or more than ft ( m) between end closures D785 2 Pressure Required for Test A PVC26 PVC22 PVC A The fiber stresses used to derive these test pressures are as follows: PVC PVC PVC PVC PVC PVC and bearing the permanent marking on the pipe. Maintain the specimens at the pressure indicated for a period of 000 h. Hold the pressure as closely as possible, but within 60 (670 kpa). Condition the specimens at the test temperature of 7.4 F (2 C) to within.6 F (62 C). Test in accordance with Test Method D598, except maintain the pressure at the values given in Tables -5 for 000 h. Failure of two of the six specimens tested shall constitute failure in the test. Failure of one of the six specimens tested in retest shall constitute failure in the test. Evidence of failure of the pipe shall be as defined in Test Method D Accelerated Regression Test Test in accordance with procedures in Test Method D598, using either free end or restrained end fittings. A minimum of six samples shall be tested. Test three specimens at a single pressure that will result in failures at or below 0.0 h. Test an additional three specimens at a single pressure that will result in failures at about 200 h. Generating additional data points to improve the LTHS or LCL, or both, is acceptable. No points shall be excluded unless an obvious defect is detected in the failure area

6 D785 2 Nominal Pipe Size TABLE 6 Burst Pressure Requirements for Water at 7 F (2 C) for PVC Plastic Pipe, Schedules 40, 80, and 20 PVC20 PVC220 PVC220 Min Burst Pressures A Schedule 40 Schedule 80 Schedule 20 PVC22 PVC26 PVC20 PVC20 PVC220 PVC220 PVC22 PVC26 PVC20 PVC20 PVC220 PVC220 PVC22 PVC26 PVC A The fiber stresses used to derive these test pressures are as follows: PVC PVC PVC PVC PVC PVC of the test sample, or there was a malfunction of the equipment. Characterize the data using the least squares regression described in Test Method D Burst Pressure Determine the minimum burst pressure with at least five specimens in accordance with Test Method D599. The time of testing of each specimen shall be between 60 and 70 s. 8.6 Flattening Flatten three specimens of the pipe each at least 2 (50 mm) long, between parallel plates in a suitable press until the distance between the plates is 40 % of the outside diameter of the pipe or the walls of the pipe touch, whichever occurs first. The rate of loading shall be uniform and such that the compression is completed within 2 to 5 m On

7 removal of the load examine the specimens for evidence of splitting, cracking, or breaking. 9. Retest and Rejection 9. If the results of any test(s) do not meet the requirements of this specification, the test(s) shall be conducted again only by agreement between the purchaser and seller. Under such agreement, minimum requirements shall not be lowered, changed, or modified, nor shall specification limits be changed. If upon retest, failure occurs, the quantity of product represented by the test(s) does not meet the requirements of this specification. 0. Product Marking 0. Quality of Marking The marking shall be applied to the pipe in such a manner that it remains legible (easily read) after installation and inspection. 0.2 Content of Marking: 0.2. Marking on the pipe shall include the following, spaced at intervals of not more than 5 ft (.5 m): Nominal pipe size (for example, 2 (50 mm)), Type of plastic pipe material in accordance with the designation code prescribed in.2.4, for example, PVC20, Schedule (40, 80, or 20, whichever is applicable) and the pressure rating in pounds per square inch (megapascals) for water at 7 F (2 C) shown as the number followed by (for example, 200 (.4 )). When the indicated pressure rating is lower than that calculated in accordance with SUPPLEMENTARY REQUIREMENTS.2. (see Appendix X), this shall be indicated by placing a star after the pressure rating, ASTM designation D785, with which the pipe complies, Manufacturer s name (or trademark), Production code with which the manufacturer can trace the year, month, day, shift, plant and extruder of manufacture for this product, and Pipe intended for the transport of potable water shall also include the seal or mark of the laboratory making the evaluation for this purpose, spaced at intervals specified by the laboratory. NOTE 9 Manufacturers using the seal or mark of a laboratory must obtain prior authorization from the laboratory concerned. NOTE 0 It is common practice to dual mark Schedule 40 piping for potable water and DWV usage in which compliance with each applicable standard is met.. Quality Assurance. When the product is marked with this designation, D785, the manufacturer affirms that the product was manufactured, inspected, sampled, and tested in accordance with this specification and has been found to meet the requirements of this specification. 2. Keywords 2. pressure pipe; PVC pipe; Schedule 40 pipe; Schedule 80 pipe; Schedule 20 pipe This requirement applies whenever a regulatory authority or user calls for product to be used to convey or to be in contact with potable water. S. Potable Water Requirement Products intended for contact with potable water shall be evaluated, tested, and certified for conformance with ANSI/NSF Standard No. 6 or the health effects portion of NSF Standard No. 4 by an acceptable certifying organization when required by the regulatory authority having jurisdiction. This requirement applies only to pipe to be used in systems that have not established other provisions for identification. S2.Pipe Marking Requirement for Reclaimed Water Systems Color identification of pipe shall be by () use of purple (violet) PVC material or (2) by use of continuous purple D785 2 stripes printed lengthwise on opposite sides of the pipe. The pipe shall be marked RECLAIMED WATER at intervals of 5 ft. or less.

8 D785 2 GOVERNMENT/MILITARY PROCUREMENT These requirements apply only to federal/military procurement, not domestic sales or transfers. S. Pipe for Reclaimed-Water System Pipe used in these systems shall be purple (violet) in color and it shall be marked Reclaimed Water. S2. Responsibility for Inspection Unless otherwise specified in the contract or purchase order, the producer is responsible for the performance of all inspection and test requirements specified here The producer may use his own or any other suitable facilities for the performance of the inspection and test requirements specified herein, unless the purchaser disapproves. The purchaser shall have the right to perform any of the inspections and tests set forth in this specification where such inspections are deemed necessary to ensure that material conforms to prescribed requirements. NOTE S2. In U.S. Federal contracts, the contractor is responsible for inspection. X. The hydrostatic design stresses recommended by the Plastics Pipe Institute are used to pressure rate PVC plastic pipe. These hydrostatic design stresses are 2000 (4 ), 600 ( ), 250 (9 ), and 000 (7 ) for water at 7 F (2 C). These hydrostatic design stresses apply only to pipe meeting all the requirements of this specification. X.2 Six PVC pipe materials are included based on the requirements of Specification D784 and the PPIrecommended hydrostatic design stresses as follows: X.2. Type I, Grade (2454-B), with a hydrostatic design stress of 2000 (4 ), designated as PVC20. X.2.2 Type I, Grade 2 (2454-C), with a hydrostatic design stress of 2000 (4 ), designated as PVC220. X.2. Type II, Grade (4-D), with a hydrostatic design stress of 2000 (4 ), designated as PVC220. X.2.4 Type II, Grade (4-D), with a hydrostatic design stress of 600 (.2 ), designated as PVC26. X.2.5 Type II, Grade (4-D), with a hydrostatic design stress of 250 (8.7 ), designated as PVC22. X.2.6 Type II, Grade (4-D), with a hydrostatic design stress of 000 (7.0 ), designated as PVC20. X. The standard method for obtaining hydrostatic basis for thermoplastic pipe materials is Test Method D287. Additional information regarding the test method and other criteria APPENDIX (Nonmandatory Information) X. SOURCE OF HYDROSTATIC DESIGN STRESSES S. Packaging and Marking for U.S. Government Procurement: S. Packaging Unless otherwise specified in the contract, the materials shall be packaged in accordance with the supplier s standard practice in a manner ensuring arrival at destination in satisfactory condition and which will be acceptable to the carrier at lowest rates. Containers and packing shall comply with Uniform Freight Classification rules or National Motor Freight Classification rules. S.2 Marking Marking for shipment shall be in accordance with Fed. Std. No. 2 for civil agencies and MIL-STD- 29 for military agencies. NOTE S. The inclusion of U.S. Government procurement requirements should not be construed as an indication that the U.S. Government uses or endorses the products described in this specification. used in developing these hydrostatic design stresses may be obtained from the Plastics Pipe Institute, a division of The Society of the Plastics Industry, 55 Lexington Ave., New York, NY 007. These hydrostatic design stresses may not be suitable for materials that show a wide departure from a straight-line plot of log stress versus log time to failure. All the data available to date on PVC pipe materials made in the United States exhibit a straight-line plot under these plotting conditions. X.4 The pipe is rated for use with water at 7 F (2 C) at the maximum internal pressures shown in Tables X.-X.. Lower pressure ratings than those calculated in accordance with.2. may be recommended, at the option of the pipe manufacturer, in which case the SDR shall be included in the marking. Experience of the industry indicates that PVC plastic pipe meeting the requirements of this specification gives satisfactory service under normal conditions for a long period at these pressure ratings. The sustained pressure requirements are related to these ratings through the slopes of the strengthtime plots of these materials in pipe form. X.5 The hydrostatic design stresses recommended by the Plastics Pipe Institute are based on tests made on pipe ranging in size from 2 to 2 2 (2.5 to 6.5 mm).

9 Nominal Pipe Size TABLE X. Water Pressure Ratings at 7 F (2 C) for Schedule 40 PVC Plastic Pipe PVC20 B PVC220 PVC220 D785 2 Pressure Ratings A PVC26 PVC22 B PVC20 B A These pressure ratings apply only to unthreaded pipe. The industry does not recommend threading PVC plastic pipe in Schedule 40 dimensions in nominal pipe sizes 6 (50 mm) and smaller. B See Appendix X for code designation.

10 D785 2 Nominal Pipe Size, TABLE X.2 Water Pressure Ratings at 7 F (2 C) for Schedule 80 PVC Plastic Pipe PVC20, PVC220, PVC220 PVC26 PVC22 PVC20 Unthreaded Threaded Unthreaded Threaded Unthreaded Threaded Unthreaded Threaded

11 Nominal Pipe Size, TABLE X. Water Pressure Ratings at 7 F (2 C) for Schedule 20 PVC Plastic Pipe PVC20, PVC220, PVC220 SUMMARY OF CHANGES Committee F7 has identified the location of selected changes to this standard since the last issue (F785 06) that may impact the use of this standard. () Increased relative humidity tolerance in sections 8. and 8.2 per Practice D68. D785 2 ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. PVC26 PVC22 PVC20 Unthreaded Threaded Unthreaded Threaded Unthreaded Threaded Unthreaded Threaded This standard is copyrighted by ASTM International, 00 Barr Harbor Drive, PO Box C700, West Conshohocken, PA , United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at (phone), (fax), or service@astm.org ( ); or through the ASTM website ( Permission rights to photocopy the standard may also be secured from the ASTM website ( COPYRIGHT/).

Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1

Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1 Designation: F 668 07 Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1 This standard is issued under the fixed designation F 668; the

More information

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D. CONDENSED CATALOG PVC HPB-0-A Effective 9//97 Revised //99 CLEAR / / / / -/ -/ -/ x/ CLEAR / / / / -/ PVC SDR. PSI (Water @ 7. F.) /.0.9.0.0 PVC SDR -/ -/ -/ 0 0 PVC SCHEDULE 0.0.7.0.00..7.7.00.000.00...

More information

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE PVC materials used in Schedule 40 and Schedule 80 pipe manufactured by Texas United Pipe, Inc., comply with the ASTM Standard D-1784 and are a Type I Grade

More information

Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1

Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1 Designation: D562 01 (Reapproved 2005) Standard Test Method for Consistency of Paints Measuring Krebs Unit () Viscosity Using a Stormer-Type Viscometer 1 This standard is issued under the fixed designation

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE 1.0 GENERAL 1.1 DESCRIPTION This section addresses the procedures to be employed for pipe bursting existing water/sewer pipelines, as identified on the drawings, and replacing with new Restrained Joint

More information

Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications 1

Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications 1 Designation: A 2/A 2M 04a e1 Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications 1 This standard is issued

More information

COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET

COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET [METRIC] A-A-59135 28 OCTOBER 1997 SUPERSEDING PPP-C-1752D(3) 1 FEBRUARY 1993 COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET The General Services Administration has authorized the use of this commercial

More information

Standard Specification for Stainless Steel Bars and Shapes 1

Standard Specification for Stainless Steel Bars and Shapes 1 Designation: A 276 06 Standard Specification for Stainless Steel Bars and Shapes 1 This standard is issued under the fixed designation A 276; the number immediately following the designation indicates

More information

Standard Practice for Evaluating Response Robot Capabilities: Logistics: Packaging for Urban Search and Rescue Task Force Equipment Caches 1

Standard Practice for Evaluating Response Robot Capabilities: Logistics: Packaging for Urban Search and Rescue Task Force Equipment Caches 1 Designation: E2592 16 Standard Practice for Evaluating Response Robot Capabilities: Logistics: Packaging for Urban Search and Rescue Task Force Equipment Caches 1 This standard is issued under the fixed

More information

COMMERCIAL ITEM DESCRIPTION CUSHIONING MATERIAL, PACKAGING, CLOSED CELL FOAM PLANK

COMMERCIAL ITEM DESCRIPTION CUSHIONING MATERIAL, PACKAGING, CLOSED CELL FOAM PLANK [METRIC] A-A-59136 28 OCTOBER 1997 SUPERSEDING PPP-C-1752D(3) 1 FEBRUARY 1993 COMMERCIAL ITEM DESCRIPTION CUSHIONING MATERIAL, PACKAGING, CLOSED CELL FOAM PLANK The General Services Administration has

More information

Royal Seal Gasketed Sewer Pipe

Royal Seal Gasketed Sewer Pipe Royal Seal Gasketed Sewer Pipe Royal Seal Gasketed Sewer Pipe Royal Seal gasketed sewer pipe with our specially designed Double Seal Locked-In (DSLI ) gasket is an extremely durable pipe with a leak proof

More information

Standard Specification for Tool Steel High Speed 1

Standard Specification for Tool Steel High Speed 1 Designation: A 600 92a (Reapproved 2004) Standard Specification for Tool Steel High Speed This standard is issued under the fixed designation A 600; the number immediately following the designation indicates

More information

ASTM D 1599 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings

ASTM D 1599 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings ASTM D 1599 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings This test method establishes the short-time hydraulic failure pressure of pipe and

More information

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

Standard Test Method for Classification of Film Systems for Industrial Radiography 1 Designation: E 1815 96 (Reapproved 2001) Standard Test Method for Classification of Film Systems for Industrial Radiography 1 This standard is issued under the fixed designation E 1815; the number immediately

More information

SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION PART 1 GENERAL.01 SECTION INCLUDES Furnishing and installing 4 inch through 16 inch high density

More information

Standard Specification for Polyethylene Plastics Molding and Extrusion Materials 1

Standard Specification for Polyethylene Plastics Molding and Extrusion Materials 1 Designation: D 4976 04a Standard Specification for Polyethylene Plastics Molding and Extrusion Materials 1 This standard is issued under the fixed designation D 4976; the number immediately following the

More information

COMMERCIAL ITEM DESCRIPTION RUBBER, SILICONE

COMMERCIAL ITEM DESCRIPTION RUBBER, SILICONE INCH-POUND A-A-59588 January 12, 2001 SUPERSEDING ZZ-R-765E/GEN May 10, 1989 COMMERCIAL ITEM DESCRIPTION RUBBER, SILICONE The General Service Administration has authorized the use of this commercial item

More information

for Rubber property Durometer hardness

for Rubber property Durometer hardness ICS 97.200/97.190/97.200.40 Jamaican Standard Test Method for Rubber property Durometer hardness 6 Winchester Road P.O. Box 113 Kingston 10 Jamaica W. I. Tel: (876) 926-3140-5, (876) 632-4275, (876) 618-1534

More information

Standard Practice for Quality Control Systems for Nondestructive Testing Agencies 1

Standard Practice for Quality Control Systems for Nondestructive Testing Agencies 1 Designation: E 1212 99 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM Standard Practice for

More information

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use

More information

Standard Specification for Tool Steels Alloy 1

Standard Specification for Tool Steels Alloy 1 Designation: A 68 8 Standard Specification for Tool Steels Alloy This standard is issued under the fixed designation A 68; the number immediately following the designation indicates the year of original

More information

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org HDPE

More information

SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE

SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent

More information

01 - Plastic Pipe Cements and Primers

01 - Plastic Pipe Cements and Primers 01 - Plastic Pipe Cements and Primers Q - What is the shelf life of the cement and primers? PVC & ABS Cements / Primers and Cleaners have 3 year shelf life from date of manufacture, and CPVC has 2 year

More information

Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement 1

Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement 1 Designation: D 792 08 Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement 1 This standard is issued under the fixed designation D 792; the number immediately

More information

Standard Specification for Flat Glass 1

Standard Specification for Flat Glass 1 : C 1036 06 Standard Specification for Flat Glass 1 This standard is issued under the fixed designation C 1036; the number immediately following the designation indicates the year of original adoption

More information

Standard Test Methods for Viscosity of Adhesives 1

Standard Test Methods for Viscosity of Adhesives 1 Designation: D 1084 97 Standard Test Methods for Viscosity of Adhesives 1 This standard is issued under the fixed designation D 1084; the number immediately following the designation indicates the year

More information

FEDERAL SPECIFICATION BEADS (GLASS SPHERES) RETRO-REFLECTIVE

FEDERAL SPECIFICATION BEADS (GLASS SPHERES) RETRO-REFLECTIVE INCH-POUND TT-B-1325D 10 July 2007 SUPERSEDING TT-B-1325C June 1, 1993 FEDERAL SPECIFICATION BEADS (GLASS SPHERES) RETRO-REFLECTIVE The General Services Administration has authorized the use of this federal

More information

pvc well casing & drop pipe

pvc well casing & drop pipe CertainTeed pvc well casing & drop pipe PVC Well Products Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due to its outstanding

More information

Standard Specification for Plastic-Lined Ferrous Metal Pipe, Fittings, and Flanges 1

Standard Specification for Plastic-Lined Ferrous Metal Pipe, Fittings, and Flanges 1 Designation: F 1545 97 e1 An American National Standard Standard Specification for Plastic-Lined Ferrous Metal Pipe, Fittings, and Flanges 1 This standard is issued under the fixed designation F 1545;

More information

Wastewater Capital Projects Management Standard Construction Specification

Wastewater Capital Projects Management Standard Construction Specification CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,

More information

Standard Specification for Seamless Ferritic and Austenitic Alloy-Steel Boiler, Superheater, and Heat-Exchanger Tubes 1

Standard Specification for Seamless Ferritic and Austenitic Alloy-Steel Boiler, Superheater, and Heat-Exchanger Tubes 1 Designation: A 213/A 213M 03b Used in USDOE-NE standards Standard Specification for Seamless Ferritic and Austenitic Alloy-Steel Boiler, Superheater, and Heat-Exchanger Tubes 1 This standard is issued

More information

Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less

Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less 3A2 008 ISTA 3 Series General Simulation Performance Procedure VERSION DATE Last TECHNICAL Change: FEBRUARY 2008 Last EDITORIAL

More information

JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes

JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes 1. Scope This Japanese Industrial Standard specifies the electric resistance welded carbon steel tubes, hereinafter

More information

PVC Gasketed & Solvent Weld Pipe

PVC Gasketed & Solvent Weld Pipe PVC Gasketed & Solvent Weld About Royal Building Products Royal Building Products has been in business for over 100 years when Royal Abbotsford, Canada facility started producing clay. With shift in demand

More information

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542 1.0 INTENT REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES 1.01 It is the intent of this specification to provide for the reconstruction of pipelines and conduits by the installation of a resin-impregnated

More information

General Guidelines for Butt, Saddle, and Socket Fusion of Unlike Polyethylene Pipes and Fittings TN-13/2007

General Guidelines for Butt, Saddle, and Socket Fusion of Unlike Polyethylene Pipes and Fittings TN-13/2007 General Guidelines for Butt, Saddle, and Socket Fusion of Unlike Polyethylene Pipes and Fittings TN-13/2007 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org

More information

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. POLYURETHANE COATING ON STEEL PIPE PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2 REFERENCE SPECIFICATIONS,

More information

Green Thread Product Data

Green Thread Product Data Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using

More information

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

POLYURETHANE LINING AND COATING ON PIPE RAW WATER POLYURETHANE LINING AND COATING ON PIPE RAW WATER PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2

More information

Standard Test Method for Water in Petroleum Products and Bituminous Materials by Distillation 1

Standard Test Method for Water in Petroleum Products and Bituminous Materials by Distillation 1 Designation: D 95 99 e1 An American National Standard American Association State Highway Transportation Standard AASHTO No. T55 Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 10.5

More information

Plastics TECHNICAL AND INSTALLATION MANUAL. (Updated June 10, 2016) TECHNICAL MANUAL TM-PL. 2001-2016 Charlotte Pipe and Foundry Co.

Plastics TECHNICAL AND INSTALLATION MANUAL. (Updated June 10, 2016) TECHNICAL MANUAL TM-PL. 2001-2016 Charlotte Pipe and Foundry Co. Plastics TECHNICAL AND INSTALLATION MANUAL ABS DWV ABS Plus Foam Core PVC DWV RePVC DWV Pipe with Recycled Content PVC Sewer & Pressure Pipe PVC Schedule 40 & 80 FlowGuard Gold CTS CPVC ReUze CTS CPVC

More information

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GII GAI GCI. GRI Test Method GM21

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA 19033-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GII GAI GCI. GRI Test Method GM21 Geosynthetic Institute 4 Kedron Avenue Folsom, PA 133-1208 USA TEL (610) 522-8440 FAX (610) 522-8441 GEI GRI GSI GAI GCI GII Revision 4: December 17, 2012 Revision schedule on pg. 11 GRI Test Method GM21

More information

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes Naue GmbH&Co.KG Quality Control and Quality Assurance Manual For Geomembranes July 2004 V.O TABLE OF CONTENTS 1. Introduction 2. Quality Assurance and Control 2.1 General 2.2 Quality management acc. to

More information

COMMERCIAL ITEM DESCRIPTION INK, MARKING, STENCIL, OPAQUE (POROUS AND NON-POROUS SURFACES)

COMMERCIAL ITEM DESCRIPTION INK, MARKING, STENCIL, OPAQUE (POROUS AND NON-POROUS SURFACES) [Metric] A-A-208C July 19, 2012 Superseding A-A-208B November 20, 1995 COMMERCIAL ITEM DESCRIPTION INK, MARKING, STENCIL, OPAQUE (POROUS AND NON-POROUS SURFACES) This Commercial Item Description is approved

More information

www.klmtechgroup.com TABLE OF CONTENT

www.klmtechgroup.com TABLE OF CONTENT Page : 1 of 19 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES

More information

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE 6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction

More information

SANITARY SEWER SPECIFICATIONS

SANITARY SEWER SPECIFICATIONS SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,

More information

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe 1. GENERAL The following supplemental sewer main specifications are intended to address the installation of high-density polyethylene

More information

DIVISION 4300 STORM DRAINAGE

DIVISION 4300 STORM DRAINAGE DIVISION 4300 STORM DRAINAGE SECTION 4305 STORM SEWER PART 1 - GENERAL 1.01 SCOPE This section covers the construction of storm sewers for the collection and transport of stormwater runoff. 1.02 REFERENCES

More information

AMERICAN SOCIETY OF CIVIL ENGINEERS. Standards Writing Manual for ASCE Standards Committees. Prepared by ASCE Codes and Standards Committee

AMERICAN SOCIETY OF CIVIL ENGINEERS. Standards Writing Manual for ASCE Standards Committees. Prepared by ASCE Codes and Standards Committee AMERICAN SOCIETY OF CIVIL ENGINEERS Standards Writing Manual for ASCE Standards Committees Prepared by ASCE Codes and Standards Committee Revised August 20, 2010 Contents Section Page 1.0 Scope, purpose,

More information

INDEX. Sec. No. Items Page Nos.

INDEX. Sec. No. Items Page Nos. INDEX Sec. No. Items Page Nos. 1. Types of Pipe............... MSSP- 2 2. Concrete Pipe............... MSSP- 2 thru MSSP-3 3. ABS and PVC Truss Pipe............... MSSP- 3 4. ABS and PVC Solid Wall Pipe...............

More information

Product Knowledge Guide. (Updated May 2015) BR-PK 2004-2015 Charlotte Pipe and Foundry Company.

Product Knowledge Guide. (Updated May 2015) BR-PK 2004-2015 Charlotte Pipe and Foundry Company. Product Knowledge Guide (Updated May 2015) BR-PK 2004-2015 Charlotte Pipe and Foundry Company. You can t beat the system. Charlotte Pipe s Retail Division Charlotte Pipe and Foundry Company is the largest

More information

Engineering Specifications

Engineering Specifications PUREFLOW PEX PRODUCTS PART 1 GENERAL 1.1 SUMMARY 1.1.1 This specification covers Branch & Main, Parallel Water Distribution Systems (MANABLOC), Cross-linked Polyethylene tubing and fittings using PEX Press

More information

Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 9.1

Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 9.1 Designation: D 1298 99 e2 An American National Standard Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 9.1 Designation: 160/99 Standard Test Method for Density, Relative Density

More information

Standard Specifications, Standard Test Methods and Codes for PE (Polyethylene) Piping Systems

Standard Specifications, Standard Test Methods and Codes for PE (Polyethylene) Piping Systems 125 Standard Specifications, Standard Test Methods and Codes for PE (Polyethylene) Piping Systems Introduction The specification, design and use of PE piping systems is addressed by a number of standard

More information

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES 33 00 00 SITE UTILITIES

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES 33 00 00 SITE UTILITIES SECTION INCLUDES Domestic Water Fire Water Service Water Well Sanitary Sewer Storm Drains Foundation Drainage RELATED SECTIONS 03 30 00 Concrete 21 00 00 Fire Suppression - Sprinklers 22 00 00 Plumbing

More information

COMMERCIAL ITEM DESCRIPTION CLOTH AND STRIP, LAMINATED OR COATED, VINYL NYLON OR POLYESTER, HIGH STRENGTH, FLEXIBLE

COMMERCIAL ITEM DESCRIPTION CLOTH AND STRIP, LAMINATED OR COATED, VINYL NYLON OR POLYESTER, HIGH STRENGTH, FLEXIBLE INCH-POUND A-A-55308 May 13, 1997 COMMERCIAL ITEM DESCRIPTION CLOTH AND STRIP, LAMINATED OR COATED, VINYL NYLON OR POLYESTER, HIGH STRENGTH, FLEXIBLE The General Services Administration has authorized

More information

R-Value and Thermal Conductivity of PEX and PE-RT TR-48/2014

R-Value and Thermal Conductivity of PEX and PE-RT TR-48/2014 R-Value and of PEX and PE-RT TR-48/2014 Foreword R-VALUE AND THERMAL CONDUCTIVITY OF PEX AND PE-RT TR-48/2014 This technical report was developed and published with the technical help and financial support

More information

The entire document shall be read and understood before proceeding with a test. ISTA 3B 2013 - Page 1 of 35

The entire document shall be read and understood before proceeding with a test. ISTA 3B 2013 - Page 1 of 35 Packaged-Products for Less-Than-Truckload (LTL) Shipment ISTA 3 Series General Simulation Performance Test PROCEDURE VERSION DATE Last TECHNICAL Change: NOVEMBER 2012 Last EDITORIAL Change: JANUARY 2013

More information

Chapter 7 Plumbing Connections

Chapter 7 Plumbing Connections Chapter 7 Plumbing Connections 7-1 General All plumbing equipment and installations must be designed, constructed, and installed in accordance with this code and where not specific, to the applicable provisions

More information

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1 ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR

More information

Standard Test Method for Analysis of Barium, Calcium, Magnesium, and Zinc in Unused Lubricating Oils by Atomic Absorption Spectrometry 1

Standard Test Method for Analysis of Barium, Calcium, Magnesium, and Zinc in Unused Lubricating Oils by Atomic Absorption Spectrometry 1 Designation: D 4628 02 An American National Standard Standard Test Method for Analysis of Barium, Calcium, Magnesium, and Zinc in Unused Lubricating Oils by Atomic Absorption Spectrometry 1 This standard

More information

725-R-599 PIPE LINING. (Revised 05-01-12) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE

725-R-599 PIPE LINING. (Revised 05-01-12) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE PIPE LINING (Revised 05-01-12) The Standard Specifications are revised as follows: SECTION 725, DELETE LINES 1 THRU 317. SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING

More information

Technical Note 802 Leak Testing of Polyethylene Pipe For Municipal and Industrial Applications Part 1 Pre-Test Considerations

Technical Note 802 Leak Testing of Polyethylene Pipe For Municipal and Industrial Applications Part 1 Pre-Test Considerations Technical Note 802 Leak Testing of Polyethylene Pipe For Municipal and Industrial Applications Part 1 Pre-Test Considerations Leak testing may be used to find leaks in a newly constructed or newly modified

More information

FOREWORD. The Plastics Pipe Institute. This Technical Note, TN-30, was first issued in January 2006 and was revised and republished in September 2013.

FOREWORD. The Plastics Pipe Institute. This Technical Note, TN-30, was first issued in January 2006 and was revised and republished in September 2013. Requirements for the Use of Rework Materials in Manufacturing of Polyethylene Gas Pipe TN-30/2013 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org FOREWORD

More information

Example Specification for Concrete using Current Building Code Requirements

Example Specification for Concrete using Current Building Code Requirements Example Specification for Concrete using Current Building Code Requirements DISCLAIMER: This specification is an example that accompanies a seminar titled The P2P Initiative: Performance-based Specs for

More information

SECTION 02400 - STORM DRAIN SYSTEM

SECTION 02400 - STORM DRAIN SYSTEM SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And

More information

Standard Specification for Cellular Glass Thermal Insulation 1

Standard Specification for Cellular Glass Thermal Insulation 1 Designation: C 552 03 Standard Specification for Cellular Glass Thermal Insulation 1 This standard is issued under the fixed designation C 552; the number immediately following the designation indicates

More information

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION Generated: Sergiy Papyshev Engineering Approved: Don Prysi Manufacturing Approved: Merzuk Ramic Quality Approved: Steven Barnett Administrative DATE DATE DATE

More information

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 * SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 * PRODUCT: Polymer (Foam-Filled) Fuel Cells 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

More inside :: Tackle even the toughest water treatment piping challenges with

More inside :: Tackle even the toughest water treatment piping challenges with More inside :: Tackle even the toughest water treatment piping challenges with Corzan Industrial Systems Corrosion to pipes, valves and fittings caused by chemicals and microbes can greatly impact the

More information

ICC-ES Evaluation Report

ICC-ES Evaluation Report ICC-ES Evaluation Report ESR-2369 Reissued May 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

SECTION 221413 FACILITY STORM DRAINAGE PIPING

SECTION 221413 FACILITY STORM DRAINAGE PIPING SECTION 221413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Terms and Conditions. 3012436v2 12285.01010

Terms and Conditions. 3012436v2 12285.01010 Terms and Conditions ACCEPTANCE. Except as otherwise agreed in a written agreement signed by both parties, these Terms and Conditions will govern Buyer s purchase order. BI Technologies acceptance of Buyer

More information

Copper and Copper Alloy Tube, Pipe and Fittings

Copper and Copper Alloy Tube, Pipe and Fittings Copper and Copper Alloy Tube, Pipe and Fittings COPPER and COPPER ALLOY TUBE and PIPE Seamless Copper Pipe: Copper pipe is almost pure copper manufactured to the requirements of ASTM B 42 - Standard Specification

More information

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary

More information

Standard Practice for Evaluating the Cache Packaging Weight and Volume of Robots for Urban Search and Rescue 1

Standard Practice for Evaluating the Cache Packaging Weight and Volume of Robots for Urban Search and Rescue 1 Designation: X XXXX-XX Work Item Number: WK12399 Standard Practice for Evaluating the Cache Packaging Weight and Volume of Robots for Urban Search and Rescue 1 This standard is issued under the fixed designation

More information

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS. CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS September 2006 Revision 7 Corning Cable Systems reserves the right to update

More information

Schedule 40 & Schedule 80 Rigid PVC Piping Systems Scroll Down for Dimensions, Components, Hangars & Supports, Fabrication Techniques

Schedule 40 & Schedule 80 Rigid PVC Piping Systems Scroll Down for Dimensions, Components, Hangars & Supports, Fabrication Techniques Schedule 40 & Schedule 80 Rigid PVC Piping Systems Scroll Down for Dimensions, Components, Hangars & Supports, Fabrication Techniques Schedule 40 Rigid PVC Piping Systems SCHEDULE 40 - DIMENSIONS Harvel

More information

SOIL-LIME TESTING. Test Procedure for. TxDOT Designation: Tex-121-E 1. SCOPE 2. APPARATUS 3. MATERIALS TXDOT DESIGNATION: TEX-121-E

SOIL-LIME TESTING. Test Procedure for. TxDOT Designation: Tex-121-E 1. SCOPE 2. APPARATUS 3. MATERIALS TXDOT DESIGNATION: TEX-121-E Test Procedure for SOIL-LIME TESTING TxDOT Designation: Tex-121-E Effective Date: August 2002 1. SCOPE 1.1 This method consists of three parts. 1.1.1 Part I determines the unconfined compressive strength

More information

IPC-SM-840C. Qualification and Performance of Permanent Solder Mask IPC-SM-840C. The Institute for. Interconnecting. and Packaging Electronic Circuits

IPC-SM-840C. Qualification and Performance of Permanent Solder Mask IPC-SM-840C. The Institute for. Interconnecting. and Packaging Electronic Circuits The Institute for Interconnecting and Packaging Electronic Circuits Qualification and Performance of Permanent Solder Mask January 1996 A standard developed by the Institute for Interconnecting and Packaging

More information

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology ENGINEERED SOLUTIONS A2 Liner Pipe for Trenchless Technology A2 Liner Pipe Restores Deteriorated Sewers Cost-Effective Rehabilitation The increasing rate of sanitary and storm sewer deterioration requires

More information

Native InDesign 2890 SaniTite Brochure 1/8" 100 300 CMYK April 17, 07

Native InDesign 2890 SaniTite Brochure 1/8 100 300 CMYK April 17, 07 Sanitary Sewer Pipe Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness

More information

SECTION 33 11 00.13 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS

SECTION 33 11 00.13 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS SECTION 33 11 00.13 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS PART 1: GENERAL 1.01 SECTION INCLUDES Furnishing and installing up to 16-inch high density polyethylene (HDPE) pipe and fittings for

More information

NAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

NAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE NAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE GENERAL a. These specifications may be used in whole or in part by any party without

More information

TRENCHLESS TECHNOLOGY GUIDELINES CLOSE FIT THERMOPLASTIC LINING

TRENCHLESS TECHNOLOGY GUIDELINES CLOSE FIT THERMOPLASTIC LINING TRENCHLESS TECHNOLOGIES RESOURCE CENTRE TRENCHLESS TECHNOLOGY GUIDELINES SECOND EDITION CLOSE FIT THERMOPLASTIC LINING NEW VERSION AUGUST 2005 1. OVERVIEW The use of liners that are deliberately deformed

More information

PVC PIPE PERFORMANCE FACTORS

PVC PIPE PERFORMANCE FACTORS PVC PIPE PERFORMANCE FACTORS PVC pipe, like all flexible pipe products, is very dependent on the surrounding soil for its structural capacity, in addition, the pipe material must have sufficient inherent

More information

Tex-421-A, Splitting Tensile Strength of Cylindrical Concrete Specimens

Tex-421-A, Splitting Tensile Strength of Cylindrical Concrete Specimens Contents: Section 1 Overview...2 Section 2 Apparatus...3 Section 3 Test Specimens...4 Section 4 Procedure...5 Texas Department of Transportation 1 08/99 06/08 Section 1 Overview Effective dates: August

More information

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe The Most Advanced Name in Drainage Systems Sanitary Sewer Pipe SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling,

More information

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL 155 E. Front Street (rear) Lititz, PA 17543 Phone (717) 625-1930 Fax (717) 625-1931 Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL CONSTRUCTION SPECIFICATIONS AND DETAILS

More information

RTV162. Electronic Grade Silicone Adhesive Sealant

RTV162. Electronic Grade Silicone Adhesive Sealant RTV162 Product Description Electronic Grade Silicone Adhesive Sealant RTV162 adhesive sealant from GE Silicones is one-component, readyto-use electronic grade silicone sealant. It cures to a tough, resilient

More information

DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted PMG 1057 Valid: 02/15 to 02/16 DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING

More information

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved

More information

MIL-STD-2073-1 Standard Practice for Military Packaging

MIL-STD-2073-1 Standard Practice for Military Packaging MIL-STD-2073-1 Standard Practice for Military Packaging Presented By: Richard Mast Date 19 July 2011 Revision 5, 7 Jun 2010 Agenda Review the organization and content of the MIL-STD-2073-1 1. Scope Purpose

More information

SPECIFICATIONS FOR STEEL PIPE

SPECIFICATIONS FOR STEEL PIPE SPECIFICATIONS FOR STEEL PIPE Published pipe standards serve three functions. 1. They dictate manufacturing and testing requirements and prescribed methods of measuring the required mechanical and physical

More information

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains

More information

CHAPTER 11 STORM DRAINAGE

CHAPTER 11 STORM DRAINAGE CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,

More information