1 rd Edition ESLON SCH80 PVC & CPVC Piping Systems Specifications & Engineering Manual
2 Best Quality from Sekisui to the World Sekisui Chemical is the leading company of plastic pipes in the world. The brand of our plastic pipe is Eslon, which is well-known as high quality all over the world. Since 1953, Eslon pipe was first on the market, Sekisui Chemical has been providing a variety of plastic pipes. Sekisui Chemical is the unique company in the various fields, who has the techniques of materials such as PVC polymerization, formulation, and CPVC denaturation of PVC resin, and the techniques of production, special long term evaluation, piping design and installation. Our excellent technique has a high reputation not only in Japan, but also in the world. Sekisui Chemical is proud of providing Schedule80 PVC & CPVC pipes and fittings for the world based on the best quality.
3 TABLE OF CONTENTS 1. Advatages of Eslon Sch80 PVC and CPVC Pipe Eslon Sch80 PVC and CPVC Pipe and Fittings Physical Properties of PVC and CPVC Material Schedule80 Pipe Schedule80 Fittings True Union Flange Gasket Installation Storage and Handling General Recoendations Rules and Guidelines Safety Precautions NOTE: Some of the information contained herein is generated by independent sources. Such information is accurate to the best of SEKISUIs' knowledge, but SEKISUI disclaims any liability for the accuracy or completeness of such information or the reliance by any party on such information. ESLON QUALITY POLICY It is the policy of all operations of Eslon to continuously strive to meet the requirements of our customers by offering products and services which are of the highest quality. This requires that we obtain thorough leadership in quality or product, quality of service, and quality of delivery, by providing a work environment which nurtures the growth and involvement of all employees. We will maintain the most effective quality system to enable us to best meet our customers needs. Copyright 2008 SEKISUI CHEMICAL CO., LTD. May not be copied in whole or part. Revision No.1, Jan. 2008
4 Understanding Safety Alert Messages There are several types of safety-alert messages which appear throughout this Technical Manual. Familiarize yourself with these types of messages and the importance of the various signal words, as explained below.! This safety alert symbol indicates important safety messages in this manual. When you see this symbol be alert to the possibility of personal injury and carefully read and fully understand the message that follows.! DANGER DANGER: Indicates an iinently hazardous situation which, if not avoided, will result in death or serious injury. Safety Signs identified by the signal word DANGER should be used sparingly and only for those situations presenting the most serious hazards.! WARNING WARNING: Indicates a potentially hazardous situation which, if not avoided, will result in death or serious injury. Hazards identified by the signal word WARNING present a lesser degree of risk of injury or death than those identified by the signal word DANGER.! CAUTION CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
5 1 Advatages of Eslon Sch80 PVC and CPVC Pipe
6 Advatages of Eslon Sch80 PVC and CPVC Pipe 5 Advantages of Eslon Sch80 PVC and CPVC Pipe Sekisui Eslon PVC and CPVC pipe have a number of outstanding features, such as high chemical resistance, easy installation, and reasonable price, which can lead to the reduction of total construction cost. Eslon PVC and CPVC can or should replace other materials of construction in size ranges available for all sorts of piping systems. CPVC (Chlorinated Polyvinyl Chloride) is another rigid pipe which has three highly-desirable characteristics, good mechanical strength at high temperatures and higher chemical resistance and relatively compared to metal. CPVC polymer is more chlorinated into PVC polymer. This extra chlorine is responsible for the material s high-temperature strength and other properties which are valuable for industrial piping. For pressure piping Advantages Chemical Resistance PVC and CPVC pipe are inert to attack by strong acids, alkalis, salt solutions, alcohols, and many other chemicals. They are dependable on corrosive applications and impart no tastes or odors to materials carried in them. They do not react with materials carried, nor act as a catalyst. All possibility of contamination, or chemical process changes, and all danger of clouding, slugging, or discoloration are eliminated. Strength PVC and CPVC pipe are highly resilient, tough and durable products that have high tensile and high impact strength. They will withstand surpris- applications, it is recoended for temperatures as high as 200 F compared with 140 F of PVC. Eslon Sch80 PVC & CPVC Pipe ranging in sizes from 1/2 through 24, and PVC fittings and PVC valves are available for light, medium, and heavy duty use. PVC and CPVC are environmentally friendly polymer in terms of low carbonic acid gas emission in manufacturing process ingly high pressure for long periods. Fire Resistance PVC and CPVC pipe products are self extinguishing and will not support combustion. They have an ASTM E-84 flame spread rate of 25 or less. Internal Corrosion Resistance PVC and CPVC pipe resist chemical attack by most acids, alkalis, salts, and organic media such as alcohols and aliphatic hydrocarbons, within certain limits of temperature and pressure. They provide the needed chemical resistance, while eliminating the disadvantages of special metals, lined piping, glass, wood, ceramics, or other special corrosion-resisting materials, which formerly had to be used.
7 External Corrosion Resistance Industrial fumes, humidity, saltwater, weather, atmospheric, or underground conditions, regardless of type of soil or moisture encountered, cannot harm rigid PVC and CPVC plastic pipe. Scratches or surface abrasions do not provide points which corrosive elements can attack. Iunity to Galvanic or Electrolytic Attack PVC and CPVC pipe are inherently iune to galvanic or electrolytic action. They can be used underground, underwater, in the presence of metals, and can also be connected to metals. Freedom from Toxicity, Odors, Tastes PVC and CPVC piping are non-toxic, odorless, and tasteless. They have been listed by the National Sanitation Foundation for use with potable water. Corrosion Free With many other pipe materials, slight corrosion may occur. The corroded particles can contaminate the piped fluid, complicating further processing, or causing bad taste, odors, or discoloration. This is particularly undesirable when the piped fluid is for domestic consumption. With PVC and CPVC, there are no corrosive by-products, therefore, no contamination of the piped fluid. Low Friction Loss The smooth interior surfaces of PVC and CPVC pipe, compared to metal and other piping materials, assure low friction loss and high flow rates. Additionally, since PVC and CPVC pipe will not rust, pit, scale, or corrode, the high flow rates will be maintained for the life of the piping system. Low Thermal Conductivity PVC and CPVC pipe have a much lower thermal conductivity factor than metal pipe. Therefore, fluids being piped maintain a more constant temperature. In most cases, pipe insulation is not required. Easy Installation and Low Installation Cost PVC and CPVC pipe are lightweight, convenient to handle, relatively flexible, and easy to install. For example, it is approximately 1/5 to 1/6 for the weight of metal. They have smooth, seamless interior walls. No special tools are required for cutting. They can be installed using solvent cementing, threading, flanging techniques. These features lead to lower installed costs than conventional metal piping. Maintenance Free Once a PVC or CPVC piping system is properly selected, designed, and installed, it is virtually maintenance free. It will not rust, scale, pit, corrode, or promote build-up on the interior. Therefore, years of trouble-free service can be expected when using Eslon PVC and CPVC pipe. Standard Approved Sekisui Eslon PVC and CPVC pipe complies with the industry standards and requirements as set forth by the American Society for Testing and Materials (ASTM) and the National Sanitation Foundation (NSF International). 6 Advantages of Eslon Sch80 PVC and CPVC Pipe ESLON SCH80 PVC & CPVC Piping Sysyems
8 Eslon Sch80 PVC & CPVC Piping System
9 2 Eslon Sch80 PVC and CPVC Pipe and Fittings 1 Physical Properties of PVC and CPVC Material Schedule80 Pipe Schedule80 Fittings True Union Flange Gasket... 30
10 1 Physical Properties of PVC and CPVC Material Properties of PVC & CPVC PIPE 9 Eslon Sch80 PVC and CPVC Pipe and Fittings SI unit ITEM Test Method unit PVC CPVC GENERAL Cell Classification ASTM D Maximum Usable Temp. C Specific 73 F(23 C) ASTM D792 g/cc 1.42± ±0.02 Water Absorption % increase 24 hrs@ 73 F(23 C) ASTM D570 % Hardness, Rockwell ASTM D Poisson s 73 F(23 C) ASTM D MECHANICAL Tensile 73 F(23 C) ASTM D638 MPa Tensile F(90 C) MPa 22.1 Tensile Modulus of 73 F(23 C) GPa Tensile Modulus of 194 F(90 C) GPa 1.52 Flexural 73 F(23 C) ASTM D790 MPa Flexural Modulus of 73 F(23 C) GPa Compressive 73 F(23 C) ε=10% ASTM D695 MPa Compressive Modulus of 73 F(23 C) GPa Izod Impact, 73 F(23 C) ASTM D256 J/m THERMAL Coefficient of Linear Expansion ASTM D696 m/m/ C x x10-5 Coefficient of Thermal Conductivity ASTM C177 Watt/m/ K Heat Deflection Temperature Under Load (264psi, annealed) ASTM D648 C Specific Heat ASTM D2766 J/ K/g ELECTRICAL Volume Resistivity ASTM D257 ohm/cm >1.0 x >1.0 x Dielectric Strength ASTM D149 volt/ >1000 >1000 Dielectric Constant ASTM D Power Factor Electrical Conductivity Non Conductor Non Conductor FIRE PERFORMANCE Flaability Rating UL-94 V-0 V-0, 5VB, 5VA Flame Spread Index <10 <10 Average Time of Burning ASTM D635 sec <5 <5 Average Extent of Burning <10 <10 Burning Rate /min Self Extinguishing Self Extinguishing Limiting Oxygen Index (LOI) ASTM D2863 LOI 45 60
11 Properties of PVC & CPVC PIPE Fitting SI unit ITEM Test Method unit PVC CPVC GENERAL Cell Classification ASTM D Maximum Usable Temp. C Specific 73 F (23 C) ASTM D792 g/cc 1.42± ±0.02 Water Absorption % increase 24 hrs@ 73 F (23 C) ASTM D570 % Hardness, Rockwell ASTM D Poisson's 73 F (23 C) ASTM D MECHANICAL Tensile 73 F (23 C) ASTM D638 MPa Tensile F (90 C) MPa 20.7 Tensile Modulus of 73 F (23 C) GPa Tensile Modulus of 194 F (90 C) GPa 1.38 Flexural 73 F (23 C) ASTM D790 MPa Flexural Modulus of 73 F (23 C) GPa Compressive 73 F (23 C) ε =10% ASTM D695 MPa Compressive Modulus of 73 F(23 C) GPa Izod Impact, 73 F (23 C) ASTM D256 J/m THERMAL Coefficient of Linear Expansion ASTM D696 m/m/ C x x10-5 Coefficient of Thermal Conductivity ASTM C177 Watt/m/ K Heat Deflection Temperature Under Load (264psi, annealed) ASTM D648 C Specific Heat ASTM D2766 J/ K/g ELECTRICAL 10 Eslon Sch80 PVC and CPVC Pipe and Fittings Volume Resistivity ASTM D257 ohm/cm >1.0 x >1.0 x Dielectric Strength ASTM D149 volt/ >1000 >1000 Dielectric Constant ASTM D Power Factor Electrical Conductivity Non Conductor Non Conductor FIRE PERFORMANCE Flaability Rating UL-94 V-0 V-0, 5VB, 5VA Flame Spread Index <10 <10 Average Time of Burning ASTM D635 sec <5 <5 Average Extent of Burning <10 <10 Burning Rate /min Self Extinguishing Self Extinguishing Limiting Oxygen Index (LOI) ASTM D2863 LOI ESLON SCH80 PVC & CPVC Piping Sysyems
12 2 Schedule80 Pipe Eslon Pipe is Manufactured to The Following Standard Specifications Type PVC Schedule 80 CPVC Schedule 80 Material (Cell Classification) ASTM D-1784 (12454) ASTM D-1784 (23447) Dimensions Coercial Classification ASTM D-1785 Type Ⅰ,Grade 1, PVC 1120 ASTM F-441 Type Ⅳ,Grade 1, CPVC Eslon Sch80 PVC and CPVC Pipe and Fittings *ASTM F480 Well Casing Eslon pipe and fittings are approved by NSF International 14 and 61. NSF standard 14 : Plastics Piping System Components and Related Materials NSF standard 61 : Drinking Water System Components - Health Effects Schedule 80 PVC and CPVC Pipe Dimensions, Weights and Maximum Operating Pressure Nominal Pipe Outside Diameter Wall Thickness Approx. Inside Diameter PVC Nominal Weight CPVC Max. operating Pressure inch kg/m kg/m MPa 1/ ± / ± ± / ± / ± ± / ± ± ± ± ± ± ± ± ± ± ± ± ± NOTE: Maximum Operating Pressure is applied to 23 C
13 3 Schedule80 Fittings Eslon Thermoplastic Fittings are manufactured to The Following Standard Specifications Type Material (Cell Classification) Dimensions Coercial Classification PVC Schedule 80 Socket-type ASTM D-1784 ASTM D-2467 Threaded-type (12454) ASTM D-2464 Type Ⅰ,Grade 1, PVC 1120 CPVC Schedule 80 Socket-type ASTM D-1784 ASTM F-439 Threaded-type (23447) ASTM F-437 Type Ⅳ,Grade 1, CPVC Eslon pipe and fittings are approved by NSF International 14 and 61. NSF standard 14 : Plastics Piping System Components and Related Materials NSF standard 61 : Drinking Water System Components - Health Effects Socket Dimensions d d l l d2 d2 d1 d1 OD PVC AND CPVC SCHEDULE 80 TAPER SOCKET DIMENSIONS (SOLVENT CEMENT STYLE) ASTM D-2467 (PVC) F-439 (CPVC) Nominal Pipe OD Inside Diameter min d Socket Entrance Diameter d1 Socket Bottom Diameter d2 Socket Length min l 1/ ± ± / ± ± ± ± / ± ± / ± ± ± ± / ± ± (89.28) ±0.20 (±0.18) (88.67) ±0.20 (±0.18) (114.73) ±0.23 (±0.20) (114.04) ±0.23 (±0.20) ± ± ± ± ± ± ± ± ± ± ± ± ± ± " ± ± " ± ± " ± ± NOTE: The numeric of ( ) indicates dimension and tolerance for CPVC. Eslon Sch80 PVC and CPVC Pipe and Fittings ESLON SCH80 PVC & CPVC Piping Sysyems
14 3 Schedule80 Fittings Thread Dimensions T S P L OD 13 Eslon Sch80 PVC and CPVC Pipe and Fittings Nominal Pipe FEMALE TAPER THREADS ASTM D-2464 (PVC) F-437 (CPVC) ASTM F-1496 Pipe OD Female Thread Min. Length T MALE TAPER THREADS ASTM D-2464 (PVC) F-437 (CPVC) ASTM F-1496 Male Thread Min. Length S Overall Pipe Thread Length L Threads Per In. N per inch AMERICAN NATIONAL STANDARD TAPER PIPE THREADS (NPT) ASME (ANSI) B ASTM F-1498 Pitch of Thread P Height of Thread h 1/ / / / /
15 Coupling Coupling S X S G L G PVC CPVC 1/ / / Coupling FT X FT L G 1-1/ / " " L G B PVC CPVC 1/ Eslon Sch80 PVC and CPVC Pipe and Fittings B 3/ / L 1-1/ / ESLON SCH80 PVC & CPVC Piping Sysyems
16 3 Schedule80 Fittings Reducing Coupling Reducing Coupling S X S L 15 Eslon Sch80 PVC and CPVC Pipe and Fittings L G PVC CPVC 3/4" x 1/2" " x 1/2" " x 3/4" /4" x 1/2" /4" x 3/4" /4" x 1" /2" x 1/2" /2" x 3/4" /2" x 1" /2" x 1-1/4" " x 1/2" " x 3/4" " x 1" " x 1-1/4" " x 1-1/2" /2" x 1-1/2" /2" x 2" " x 1" " x 1-1/2" " x 2" " x 2-1/2" G L G PVC CPVC 4" x 2" " x 2-1/2" " x 3" " x 4" " x 3" " x 4" " x 5" " x 4" " x 6" " x 8" " x 8" " x 10" " x 12" " x 12" " x 14" Combination Table of Coupling +:Coupling without Bushing +B: with one Bushing +B*2: with 2 pieces of Bushing Inlet Reducing 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" 5" 6" 8" 10" 12" 14" 16" 1/2" + 3/4" + + 1" /4" /2" " /2" +B +B +B +B " +B +B + +B " +B +B +B +B +B " +B*2 +B*2 +B +B +B +B +B +B + + 6" +B*2 +B*2 +B +B +B +B +B " +B*2 +B*2 +B +B +B +B +B +B + +B " +B*2 +B*2 +B*2 +B*2 +B*2 +B*2 +B +B*2 +B " +B*2 +B*2 +B*2 +B*2 +B*2 +B*2 +B +B*2 +B " +B*2 +B*2 +B*2 +B +B +B " +B*2 +B*2 +B*2 +B +B +B + + +
17 H H H 90 Elbow 90 Elbow S X S G H G H PVC CPVC 1/ / / Elbow FT X FT G H 1-1/ / " " G H PVC CPVC 1/ / Eslon Sch80 PVC and CPVC Pipe and Fittings / / / Elbow S X FT G2 H G1 G2 H PVC CPVC 1/ / G / / / ESLON SCH80 PVC & CPVC Piping Sysyems
18 3 Schedule80 Fittings 45 Elbow 45 Elbow S X S G G H PVC CPVC 1/ / H / Eslon Sch80 PVC and CPVC Pipe and Fittings 45 Elbow FT X FT G 1-1/ / " " G H PVC CPVC 1/ / / H 1-1/ / Elbow S X FT G1 G2 H PVC CPVC G2 1/ / G1 1-1/ H 1-1/ /
19 Tee Tee S X S X S G H PVC CPVC 1/ H 3/ / Tee FT X FT X FT H G H 1-1/ / G H PVC CPVC 1/ / Eslon Sch80 PVC and CPVC Pipe and Fittings / / G H 2-1/ Tee S X S X FT G H PVC CPVC H 1/ / / G H 1-1/ / ESLON SCH80 PVC & CPVC Piping Sysyems
20 3 Schedule80 Fittings Reducing Tee 19 Eslon Sch80 PVC and CPVC Pipe and Fittings H2 G2 Reducing Tee S X S G1 H1 G1 G2 H1 H2 PVC CPVC 3/4" x 1/2" " x 1/2" " x 3/4" /4" x 1/2" /4" x 3/4" /4" x 1" /2" x 1/2" /2" x 3/4" /2" x 1" /2" x 1-1/4" " x 1/2" " x 3/4" " x 1" " x 1-1/4" " x 1-1/2" /2" x 1-1/2" /2" x 2" " x 1-1/2" " x 2" " x 2-1/2" " x 2" " x 2-1/2" " x 3" " x 4" " x 3" " x 4" " x 5" " x 3" " x 4" " x 6" " x 4" " x 8" " x 4" " x 8" " x 10" " x 12" " x 12" " x 14"
21 H2 Combination Table of Tee +:Tee without Bushing +B: with one Bushing +B*2: with 2 pieces of Bushing Main Branch 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" 5" 6" 8" 10" 12" 14" 16" 1/2" + 3/4" + + 1" /4" /2" " /2" +B +B +B +B " +B +B +B +B " +B +B +B +B +B " +B*2 +B*2 +B +B +B +B +B +B + + 6" +B*2 +B*2 +B +B +B +B +B " +B*2 +B*2 +B +B +B +B +B + + +B " +B*2 +B*2 +B +B +B +B +B +B + +B*2 +B " +B*2 +B*2 +B +B +B +B +B +B + +B*2 +B " +B*2 +B*2 +B*2 +B +B +B " +B*2 +B*2 +B*2 +B +B +B Reducing Tee Reducing Tee S X S X FT G2 G1 H1 G1 G2 H1 H2 PVC CPVC 3/4" x 1/2" " x 1/2" " x 3/4" /4" x 1/2" /4" x 3/4" /4" x 1" /2" x 1/2" /2" x 3/4" /2" x 1" /2" x 1-1/4" " x 1/2" " x 3/4" " x 1" " x 1-1/4" " x 1-1/2" /2" x 1-1/2" /2" x 2" " x 1-1/2" " x 2" " x 2-1/2" " x 2" " x 2-1/2" " x 3" " x 4" " x 3" " x 4" " x 3" " x 4" " x 4" " x 4" Eslon Sch80 PVC and CPVC Pipe and Fittings ESLON SCH80 PVC & CPVC Piping Sysyems
22 3 Schedule80 Fittings Reducing Bushing Reducing Bushing S X S 21 Eslon Sch80 PVC and CPVC Pipe and Fittings L1 L S L L1 S PVC CPVC 3/4" x 1/2" " x 1/2" " x 3/4" /4" x 1/2" /4" x 3/4" /4" x 1" /2" x 1/2" /2" x 3/4" /2" x 1" /2" x 1-1/4" " x 1/2" " x 3/4" " x 1" " x 1-1/4" " x 1-1/2" /2" x 1-1/2" /2" x 2" " x 1" " x 1-1/2" " x 2" " x 2-1/2" " x 1" " x 1-1/4" " x 1-1/2" " x 2" " x 2-1/2" " x 3" " x 4" " x 3" " x 4" " x 5" " x 4" " x 6" " x 6" " x 8" " x 6" " x 8" " x 10"
23 Combination Table for Reducing Bushing +:Bushing +B: with an additional Bushing +B*2: with two additional Bushing Bushing 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" 5" 6" 8" 10" 12" 1/2" 3/4" + 1" /4" /2" " /2" +B +B +B +B + + 3" +B +B + +B " +B +B " +B*2 +B*2 +B +B +B +B +B +B + 6" +B*2 +B*2 +B +B +B +B +B " +B*2 +B*2 +B +B +B +B +B +B + +B + 10" - - +B*2 +B*2 +B*2 +B*2 +B*2 +B*2 +B +B " - - +B*2 +B*2 +B*2 +B*2 +B*2 +B*2 +B +B Bushing Reducing Bushing S X FT L1 L S L L1 S PVC CPVC 3/4" x 1/2" " x 1/2" " x 3/4" /4" x 1/2" /4" x 3/4" /4" x 1" /2" x 1/2" /2" x 3/4" /2" x 1" /2" x 1-1/4" " x 1/2" " x 3/4" " x 1" " x 1-1/4" " x 1-1/2" /2" x 1-1/2" /2" x 2" " x 1" " x 1-1/2" " x 2" " x 2-1/2" " x 1" " x 1-1/4" " x 1-1/2" " x 2" " x 2-1/2" " x 3" " x 4" " x 3" " x 4" " x 4" Eslon Sch80 PVC and CPVC Pipe and Fittings ESLON SCH80 PVC & CPVC Piping Sysyems
24 3 Schedule80 Fittings Male Adapter Male Adapter Mpt X S L L d B PVC CPVC 1/ / d B / Eslon Sch80 PVC and CPVC Pipe and Fittings Female Adapter Female Adapter S X FT G 1-1/ / L G B PVC CPVC 1/ / B / / L /
25 Cap Socket Cap L PVC CPVC 1/ / / Threaded Cap L B 1-1/ / L B PVC CPVC 1/ / Eslon Sch80 PVC and CPVC Pipe and Fittings / L 1-1/ / ESLON SCH80 PVC & CPVC Piping Sysyems
26 3 Schedule80 Fittings Plug Cap and Plug Mpt Plug L B PVC CPVC 1/ / B / Eslon Sch80 PVC and CPVC Pipe and Fittings Nipple L 1-1/ / CLOSE SHORT inch L PVC CPVC 1/2 1-3/4", 2", 3", 4", 5", 6", 8", 10", 12" 3/4 1-3/4", 2", 3", 4", 5", 6", 8", 10", 12" 1 2", 3", 4", 5", 6", 8",10",12" L L 1-1/4 2", 3", 4", 5", 6", 8", 10", 12" 1-1/2 2", 3", 4", 5", 6", 8", 10", 12" 2 2", 3", 4", 5", 6", 8", 10", 12" LONG 2-1/2 3", 4", 5", 6", 8", 10", 12" 3 4", 5", 6", 8", 10", 12" 4 4", 5", 6", 8", 10", 12" L
27 4 True Union Union (O-Ring Seat) Union (O-Ring Seat) S X S L G PVC CPVC 1/2" /4" O-ring: EPDM. FKM Union (O-Ring Seat) FT X FT G L 1" /4" /2" " /2" " " L G PVC CPVC Eslon Sch80 PVC and CPVC Pipe and Fittings 1/2" /4" " G 1-1/4" O-ring: EPDM. FKM L 1-1/2" " /2" " " ESLON SCH80 PVC & CPVC Piping Sysyems
28 5 Flange One Piece Flange Flange (ANSI) - Socket (ASTM) 27 Eslon Sch80 PVC and CPVC Pipe and Fittings C D n-φh t L Flange (JIS) - Socket (ASTM) L t C D n h PVC CPVC 1/2" /4" " /4" /2" " /2" " " " " " NOTE: Flange bolt hole patterns meet ANSI B16.5, class 150 L t C D n-φh L t C D n h PVC CPVC 1/2" /4" " /4" /2" " /2" " " " " " NOTE: Flange bolt hole patterns meet JIS B2220
29 Flange (ANSI) -Threaded L t C D n-φh Van Stone Flange Flange (ANSI) - Socket (ASTM) L t C D n-φh L t C D n h PVC CPVC 1/2" /4" " /4" /2" " /2" " " NOTE: Flange bolt hole patterns meet ANSI B16.5, class 150 Pressure MPa L t C D n h PVC CPVC 1/2" /4" " /4" /2" " /2" " " " " " " " " " " " 24" Eslon Sch80 PVC and CPVC Pipe and Fittings NOTE: Flange bolt hole patterns meet ANSI B16.5, class 150 ESLON SCH80 PVC & CPVC Piping Sysyems
30 5 Flange Van Stone Flange Flange (JIS) - Socket (ASTM) 29 Eslon Sch80 PVC and CPVC Pipe and Fittings Flange (ANSI) t C D n-φh Blind Flange t C D n-φh L t C D n h PVC CPVC 2" /2" " " " " " " " " " " " NOTE: Flange bolt hole patterns meet JIS B2220 NOTE: Flange bolt hole patterns meet ANSI B16.5 class 150 *For more than 14'', please contact us t C D n h PVC CPVC 1/2" /4" " /4" /2" " /2" " " " " " " " " * "* "* "* "*
31 6 Gasket Eslon PTFE Gasket Eslon PTFE Gasket ANSI B16.5 Detail at sealing part T D C d D1 D2 EPDM PTFE 3 n-φh Eslon EPDM Gasket Eslon EPDM Gasket ANSI B16.5 d D1 D2 C D n-φh T Weight (kg/pc) N m{kgf-cm} 1/2" {160} 3/4" {160} 1" {350} 1-1/4" {350} 1-1/2" {350} 2" {350} 2-1/2" {520} 3" {520} 4" {520} 5" {630} 6" {630} 8" {680} 10" {1020} 12" {1360} 30 Eslon Sch80 PVC and CPVC Pipe and Fittings d D1 D2 C D n-φh Weight (kg/pc) N m{kgf-cm} 1/2" {140} 3/4" {140} 1" {200} 1-1/4" {200} 1-1/2" {200} Detail at sealing part 3 5 2" {340} 2-1/2" {340} 3" {410} n-φh 4" {410} 5" {550} d 6" {680} D1 D2 C 8" {680} 10" {890} 12" {1020} D ESLON SCH80 PVC & CPVC Piping Sysyems
32 Eslon Sch80 PVC & CPVC Piping System
33 3 Installation 1 Storage and Handling General Recoendations Rules and Guidelines... 36
34 1 Storage and Handling 33 Installation Buyer s Acceptance of Materials The person responsible for receiving the pipe should always carefully inspect as much of the pipe as possible before unloading. The receiver should look for transportation damage such as a shift in the load, tie-down straps overtightened, or signs of rough treatment. LTL (less than truckload) pipe shipments that arrive in a closed trailer should be checked as soon as the trailer is opened. Make sure that the pipe has not been toploaded with metallic piping, crates, machinery or any other objects that might crush or impact the plastic pipe. The ends of the pipe should be visually inspected for cracks, cuts, gouges, or heavy deformations. In some cases, especially for large diameter pipe 4 and above, it would be advisable to inspect the bore of the pipes for internal cracks or splits that may have occurred as a result of loading or transportation. The use of a strong flashlight may be necessary to inspect the inside diameter beyond the ends of the pipe. Any and all damages should be witnessed by the truck driver and clearly noted on the transportation documentation with a copy retained by the receiver. The carrier and Eslon should be iediately notified of any damages or missing pipe, or items incorrectly shipped. Unloading and Handling After the pipe has been thoroughly inspected and inventoried, it should be unloaded with reasonable care and effort. The person receiving the pipe must decide the means by which the pipe is unloaded and is responsible for any damages that occur during the unloading process. Never push or drag a palletized load of pipe from a truck bed. Pipe should not come into severe contact with sharp objects such as corners of truck beds, loading docks and buildings, forks on forklift trucks, and rocks or other objects on the ground. Forklift forks must never be inserted into the ends of the pipe as a means of lifting or moving. Handling and Storing on Site Incorrect way to load pipes Correct way to load pipes Incorrect way to off-load Correct way to off-load On-site transport DO NOT DRAG NOTE: The impact resistance and flexibility of PVC and especially CPVC pipe are reduced by lower temperature conditions. The impact strength for both types of piping materials will decrease as temperatures approach 32 F (0 C) and below. Extreme care should be taken when unloading and handling pipe in cold weather. Dropping pipe from a truck or forklift can cause damage. Methods and techniques normally used in warm weather may not be acceptable at the lower temperature range.
35 Pipe Storage Indoor storage of pipe is recoended but may not always be convenient. Therefore, when storing pipe outdoors, choose a flat, dry location that will minimize dirt and foreign matter accumulation in the bore and belled end. Palletized pipe should be stacked with wooden pallet bracings touching each other. Stack height will depend on the pipe diameter, the slope of the terrain, and the weather conditions. As a general precaution, palletized pipe should not be stacked higher that eight feet. This should be determined and approved by the site engineer or responsible management official. Loose pipe lengths should be stored in racks or dunnage that will evenly support the pipe to prevent longitudinal sag. If pipe is not well supported, especially in warmer weather, it will become permanently bowed and will be difficult to install. The pipe must be protected from the sun and extreme heat. Protect the pipe by covering it with an opaque tarp, leaving the ends open to allow for air circulation through and around the pipe. When pipe is not protected from the sun, extended exposure to ultraviolet rays will cause discoloration. The amount of time in years necessary to cause this will vary with the geographic location and the orientation of the pipe to the sun. 34 Installation Outdoor Storage Indoor Storage Min 3 feet (1m) Spacing Shade Max 8 feet (2.5m) Max 8 feet (2.5m) Min 3 feet (1m) 75 minimum width Ground Level Fitting Storage The person responsible for receiving the fittings should take an accurate count of the incoming order and report any discrepancies to Eslon and the carrier. Fittings packaged in damaged boxes should be closely inspected. Store fittings in their original packaging. If they must be removed from their boxes, separate them by material type (PVC vs. CPVC), geometric configuration, and diameter size. Never combine your plastic fitting inventory with metallic materials. Avoid storing fittings near an open flame or source of extreme heat. ESLON SCH80 PVC & CPVC Piping Sysyems
36 2 General Recoendations 35 Installation WARNING 1. Solvent Cement Welding This method of joining is very simple and reliable if it is followed correctly, but any deviations from the recoended basic steps may reduce the strength and integrity of the joint. The procedures for preparation, insertion, and curing should be followed very carefully. 2. Expansion and Contraction The coefficient of linear expansion of PVC and CPVC pipe is greater than that of metallic piping; therefore, take this factor into consideration when designing and installing a PVC or CPVC piping system. 3. Hanging and Supporting The modulus of elasticity of PVC and CPVC pipe is smaller than that of metal pipes. Maximum working temperature and room temperature should be considered when determining the required support spacing. 4. Trench Preparation When laying PVC and CPVC pipe below the ground, care should be taken to remove all rocks, boards, empty primer and cement cans, brushes, bottles and other debris from the trench. Smaller diameters of pipe should be snaked in the trench to allow for expansion and contraction. If solvent cement welding is used for the method of joining, snaking, pressure testing, and pipe movement should not be done until after the joints have been given sufficient time to dry. 5. Avoid Bending Pipe Pipe should not be bent in trenches or in above ground installations. Pipe and joints that are stressed can reduce pressure rating and cause failures. 6. Protect Plastic Pipe from Contact with Hard and Pointed Objects. Impact resistance is lower than for metals. WARNING!! Failure to follow the safety precautions below may NEVER use compressed air or gas in PVC/CPVC pipe result in misapplication or improper installation and and fittings. testing which can cause severe personal injury and/ NEVER test PVC/CPVC pipe and fittings with compressed air or gas, or air-over-water boosters.w or property damage. ONLY use PVC/CPVC pipe for water and approved chemicals. Use of compressed air or gas in PVC/CPVC pipe and fittings can result in explosive failures and cause severe injury or death. 7. Testing 7.1 NEVER use compressed air, gas or air-over-water boosters to pressure test PVC or CPVC piping systems. ONLY hydrostatic pressure testing is to be conducted on PVC and CPVC piping systems. Compressed air or gases can surge to high pressures and cause explosive failures that could seriously injure personnel. 7.2 Carefully follow all instructions for hydrostatic pressure testing. Failure to follow these instructions can result in a system failure. 7.3 Before water-testing a system, always bleed all entrapped air from system. Entrapped air is a major cause of surge and burst failure in plastic piping systems.
37 3 Rules and Guidelines Solvent Cement Welding Joints Joining Equipment and Material - Cutting Tool Saw & Miter Box or Pipe Cutter (Ratchet Type, Wheel Type) - Pipe deburring & beveling tool, file or knife - Solvent Cement PVC cement for PVC materials, CPVC cement for CPVC materials - Primer - Cleaner - Cotton Rag - Square - Scale - Felt-tip Pen - Tape Measure - Brush - Insertion Tool (6 and above) - Container (Metal Cans to Hold Cement or Primer) This flare must be removed with a file or deburring tool, as it will scrape the cement away when pipe is inserted into the fitting Installation 3 1. Cutting 1234 Pipe ends must be cut square. Check the pipe end with a square to make sure it has been cut squarely. Note: A diagonal cut reduces bonding area in the most effective and critical part of the joint. Wheel type cutters are not generally recoended for large diameters since they tend to raise flare at the pipe end. 4 ESLON SCH80 PVC & CPVC Piping Sysyems
38 3 Rules and Guidelines 37 Installation 2. Deburring 5 All burrs, chips, filings, etc., should be removed from both around the pipe before joining. Use a knife, deburring tool or a half-round coarse file. All pipe ends should be beveled from 45 degrees. Note: Failure to chamfer the edge of the pipe may remove cement from the fitting socket, causing the joint to leak. 4. Test Dry Fit of the Joint Check pipe and fittings for dry fit before cementing. The pipe should be inserted to the fitting easily about 1/3 to 2/3 of the socket depth. 5. Depth-Of-Entry Mark 89 Measure the socket depth of the fitting and mark this distance on the pipe O.D. This reference mark can be used when joining to ensure the pipe is completely bottomed into the fitting during assembly Inspection, Cleaning 67 Visually inspect the inside of the pipe and fitting sockets and remove all dirt, grease or moisture with a clean dry rag. Check pipes and fittings possible damage such as splits or cracks and replace if necessary Priming 1011 This process is necessary to penetrate and soften both pipe and fitting socket surfaces for cementing process. Apply primer to the surface of the pipe and fitting socket with a natural bristle brush. Move quickly without hesitation to the cementing procedure while surfaces are still wet with primer.
39 Recoended Brush for Primer and Cement Application Nominal Pipe Brush Width 11 1/2 3/ /4 1-1/ / / /2 1-1/2 * Use Only Natural Bristle 1-1/2 to 2 1-1/2 to 2-1/2 2 to to 5 4 to 6 6 to 8 6 to 8 8. Joint Assembly 14 Work quickly, insert the pipe into the fitting socket bottom with a one-quarter turn to evenly distribute the cement. Do not continue to rotate the pipe after it has reached the bottom of the fitting socket. A good joint will have sufficient cement to make a bead all the way around the outside of the fitting hub. Hold the pipe and fitting together for a minimum of 30 seconds to make sure the pipe does not move or push out of the socket. Installation 7. Application of Solvent Cement 1213 Apply the solvent cement evenly and quickly around the outside of the pipe at a width a little greater than the depth of the fitting socket while the primer is still wet. Apply a light coat of cement evenly around the inside of the fitting socket. Avoid puddling. Apply a second coat of cement to the pipe end. NOTE: Read all warnings on primer and cement cans Cleanup 15 Remove all excess cement from around the pipe and fitting with a dry cotton rag while the cement is still soft ESLON SCH80 PVC & CPVC Piping Sysyems
40 3 Rules and Guidelines 10. Initial Set Time Initial set time is the necessary time to allow before the joint can be carefully handled. 39 Initial Set Schedule Temperature Range Pipe s 1/2" to 1-1/4" Pipe s 1-1/2" to 2" Pipe s 2-1/2" to 8" Pipe s 10" to 15" Pipe s 15"+ 60 to 100 F 2 min 5 min 30 min 2 hrs 4 hrs 40 to 60 F 5 min 10 min 2 hrs 8 hrs 16 hrs 0 to 40 F 10 min 15 min 12 hrs 24 hrs 48 hrs Note: In damp or humid weather allow 50% more set time. Installation 11. Joint cure time Joint cure time is the necessary time to allow before pressurizing system. Joint Cure Schedule inch-lb Unit Temperature range during assembly and cure periods Pipe s 1/2" to 1-1/4" Pipe s 1-1/2" to 2" Pipe s 2-1/2" to 8" Pipe s 10" to 15" Pipe s 15"+ up to 150psi up to 150psi up to 150psi up to 100psi up to 100psi 60 to 100 F 1 hour 2 hours 6 hours 48 hours 72 hrs 40 to 60 F 2 hours 4hours 12 hours 96 hours 6 days 20 to 40 F 8 hours 16 hours 72 hourrs 8 days 14 days S I Unit Temperature range during assembly and cure periods Pipe s 1/2" to 1-1/4" Pipe s 1-1/2" to 2" Pipe s 2-1/2" to 8" Pipe s 10" to 15" Pipe s 15"+ up to 1MPa up to 1MPa up to 1MPa up to 0.7MPa up to 0.7MPa 15 to 40 C 1 hour 2 hours 6 hours 48 hours 72 hrs 5 to 15 C 2 hours 4hours 12 hours 96 hours 6 days - 5 to 5 C 8 hours 16 hours 72 hourrs 8 days 14 days Note: In damp or humid weather allow 50% more cure time. Helpful Hints 1. Work quickly and carefully. 2. Use liberal amounts of fresh cement. 3. Do not attempt cementing in the rain or in the presence of moisture. 4. Do not cement when the temperature is below 40 F or above 90 F under direct sunlight. 5. Do not take shortcuts or bypass recoended steps. 6. Consult your cement manufacturer for specific questions or problems Applicable Specification for Solvent Welding ASTM D-2564 : Solvent cements for PVC plastic pipe and fitting ASTM D-2855 : Marking solvent cemented joist with PVC pipe and fitting
41 ASTM A-493 : Solvent cements for CPVC plastic pipe and fitting ASTM A-656 : Primers for use in solvent cement joints of PVC plastic pipe and fitting Hydrostatic Pressure Testing! WARNING Failure to follow the safety precautions below may result in misapplication or improper installation and testing which can cause severe personal injury and/or property damage. 1. The last assembled joint should be fully cured before filling the system with water. 2. All valves and air relief mechanisms should be opened at the ends and elevations. The system should be filled slowly, flow velocities should not exceed 1 foot per second. This will prevent surge, water haer, and air entrapment. 3. Water flow should continue until all entrapped air is completely flushed out of every branch of the system. Maintain the 1 ft/s velocity until every valve is checked. A rapid fluctuation of gauge needle during pressure rise may be an indication that entrapped air still remains in the system. Systems should include the appropriate air relief and vacuum breaker valves to vent air during normal operation after installation. Entrapped air is major cause of surge and burst failure in plastic piping systems. 4. After filling the system, do not pressurize until the responsible engineer is present to witness the test. All personnel in the vicinity of the system should wear safety glasses and hard hats. High voltage electrical equipment should be shielded from a possible spray. 5. The piping system should be pressurized to 125% of its maximum design operating pressure. This pressure must not exceed 1.5 times the working pressure of the lowest rated component in the system, i.e. flanges, unions, thread parts, valves, etc. 6. The pressure test should not exceed 1 hour. This should provide enough time to inspect all joints for leaks. If leaks are found, pressure must be relieved to repair the leak. The system should then be recharged and retested. Consult the factory if you have any questions concerning these steps.! CAUTION CAUTION identifies hazards or unsafe practices which can result in minor injury or product or property damage if instructions, including recoended precautions, are not followed. Applicators Select a suitable pure bristle type paint brush. Use a proper width brush or roller to apply the primer and cement (see chart below). Speedy application of cement is important due to its fast drying characteristics. IMPORTANT NOTE: A dauber type applicator should only be used on pipe sizes 2 and below. For larger diameter pipe, a brush, swab, or roller must be used. 40 Installation ESLON SCH80 PVC & CPVC Piping Sysyems
42 3 Rules and Guidelines 41 Installation 2 Threaded Connection A. Selection of Materials Power Threading Machine Threading Rachet and Pipe Vise (if hand pipe stock is used) Pipe Dies designed for plastic Strap Wrench Teflon* Tape or an approved Teflon Paste Cutting and Deburring Tool Ring Gauge (L-1) *Trademark of the EJ DuPont Company have a negative front rake angle of 5 to 10 PVC and CPVC is readily threaded and caution should be taken not to over-thread. B. Making the Pipe Thread 1. Cutting and Deburring PVC or CPVC pipe should be cut square and smooth for easy and accurate threading. A miter box or similar guide should be used when sawing is done by hand. Burrs should be removed inside and out using a knife or plastic pipe deburring tool. 2. Threading Threading Schedule 80 PVC and CPVC pipe can easily be accomplished using either a standard hand pipe stock or a power operated tool. Cutting dies should be clean and sharp. Power threading machines should be fitted with dies having a 5 negative front rake and ground especially for plastic pipe. Self-opening die heads, and a slight chamfer to lead the dies will speed the operation; however, dies should not be driven at high speeds or with heavy pressure. When using a hand held cutter, the pipe should be held in a pipe vise. To prevent crushing or scoring of the pipe by the vice jaws, some type of protective wrap such as canvas, emery paper, rubber, or light metal sleeve should be used. For hand stocks, the dies should 3. Preparing the Threaded Pipe A ring gauge should be used to check the accuracy of the threads. Tolerance = ± 1-1/2 turns. The threads should then be cleaned by brushing away cuttings and ribbons. After cleaning, apply a thread lubricant such as Teflon tape to the threaded portion of pipe. Wrap the tape around the entire length of threads beginning with number two thread from the end. The tape should slightly overlap itself going in the same direction as the threads. This will prevent the tape from unraveling when the fitting is tightened on the pipe. Overlapping in the wrong direction and the use of too much tape can affect tolerances between threads. This can generate stress in the wall of female fittings resulting in failure during operations.
43 4. Assembly of Threaded Joints After applying thread lubricant, screw the threaded fitting onto the pipe. Screwed fittings should be started carefully and hand tightened. Threads must be properly cut and a good quality thread lubricant/tape must be used. If desired, the joint may be tightened with a strap wrench. IN NO CASE SHOULD A STILLSON TYPE WRENCH BE USED. The jaws of this type of wrench will scar and damage the pipe wall. Fittings should be threaded together until hand tight with an additional 1 to 1-1/2 turns more. Avoid stretching or distorting the pipe, fittings or threads by over tightening. (2.) Some Teflon pastes contain chemicals that may be harmful to the pipe and fittings. You should consult the supplier or manufacturer of the paste before use. (3.) Avoid screwing metallic male threads into plastic female threads. If connections to metal threads have to be made, the preferred method is to screw a plastic male thread into a metallic female thread. There are a variety of plastic fittings that are molded with metallic male or female NPT threaded inserts. The corrosion resistance of the metal insert will have to be taken into consideration. Consult the factory or your Eslon sales person for the availability of these metal insert fittings. *Trademark of the E.I. DuPont Company. 42 Installation NOTE: (1.) Never apply solvent cement to threaded pipe or threaded fittings. Do not allow cleaners, primers, or solvent cements to run or drip into the threaded portion of the fitting. ANSI B Taper Pipe Thread Dimensions A B C 60 E D 60 Pipe Threads Nominal Outside Diameter D Number of Threads Per Inch Normal Engagement By Hand C Length of Effective Thread A Total Length : End of pipe to vanish point B Pitch Diameter at end of Internal Thread E Depth of Thread (Max.) inch inch inch inch inch inch 1/2" /4" " /4" /2" " /2" " " ESLON SCH80 PVC & CPVC Piping Sysyems
44 3 Rules and Guidelines 43 Installation 3 Flange Connection A. Selection of Materials ESLON Gasket must be resistant to chemicals flowing through the line. Fasteners-bolts, nuts, and washers, also resistant to the chemical environment. (Threads should be well lubricated.) Torque Wrench-a necessity for tightening bolts in a manner that guards against excessive torque. B. Flange Assembly 1. Join the flange to the pipe as outlined in the solvent cementing section or in the threading section depending on the joining method desired. 2. Align the flanges and gasket by inserting all of the bolts through the matching bolt holes. Proper mating of flanges and gaskets is very important for a positive seal. 3. Using a torque wrench, tighten each bolt in a gradual sequence as outlined by the flange sketch. For final tightening of all bolts, find the recoended torque value in the chart below.! CAUTION 1. Do not over-torque flange bolts. 2. Use the proper bolt tightening sequence. 3. Make sure the system is in proper alignment. 4. Flanges should not be used to draw piping assemblies together. 5. Flat washers must be used under every nut and bolt head. Recoended Torque Pipe No. Bolt (IPS) Holes Bolt Diameter Approx. Bolt Length* in. 1/2 4 1/2 2 1/ /4 4 1/2 2 1/ /2 2 1/ /4 4 1/ /2 4 1/ /8 3 1/ /2 4 5/ /8 3 1/ / / / / / Recoended Torque ft./lbs. 12-Bolt 12 8-Bolt Bolt Bolt lengths were calculated using two Eaton flanges. Additional accessories or different mating surfaces will alter these numbers NOTE: Flange bolt hole pattern meets ANSI B16.5
45 4 Safety Precautions
46 Safety Precautions 45 Safety Precautions PVC and CPVC plastic piping systems will give excellent, maintenance-free performance over many years use,as long as the application and system design is correct and installation is properly done. It is most important to know the physical properties and limitations of PVC and CPVC plastic pipe when selecting these materials for an application and when designing the system. In every case, carefully read and follow installation procedures. It is very important to know the reputation and abilities of your installation crew or contractor. Professional engineering design of the system and close supervision of the assemblyinstallation procedures are highly recoended. Any questions concerning the application or installation of PVC and CPVC piping products should be directed to the supplier, manufacturer or consultant. WARNING! Failure to follow the safety precautions below may result in misapplication or improper installation and testing which can cause severe personal injury and/ or property damage. General 1. Protect plastic pipe from contact with hard and pointed objects Impact resistance is lower than for metals. 2. Avoid bending pipe Pipe should not be bent in trenches or in above ground installations. Pipe and joints that are stressed reduce pressure rating and can cause failures. 3. Protect pipe from extreme heat and cold. Extremes of heat and cold can cause failure. Allowing liquids to freeze inside PVC/CPVC and metallic piping can cause the pipe and/or the joints to crack. Freeze protection should be designed into the system. Heat beyond design limits can also cause failures. 4. Protect pipe from sunlight. PVC and CPVC pipe compounds normally do not provide extended protection from the ultraviolet rays of the sun. Therefore, unless the material has been specially formulated to provide protection, the product must be protected from sunlight or some damage may occur after years of exposure. Application 1. NEVER use PVC and CPVC piping materials to transport compressed air or gases. Compressed air or gases can surge to high pressures and cause explosive failures that could seriously injure personnel. PVC and CPVC pipe and fittings are excellent products in transporting water and corrosive chemicals. 2. Only use approved chemicals. Certain chemicals, especially petroleum distillates and derivatives, can cause failure. Every chemical should be verified and approved in the manufacturer's chemical resistance chart. System Design 1. Allow for flexibility in the design of the system. Expansion and contraction is greater than for metals. This can cause breaks and leaking points if system design is not flexible to allow for movement. When laying smaller diameters of pipe below ground, the pipe should be "snaked" in the trench to allow for expansion and contraction. If solvent cement welding is used for the method of joining, snaking, pressure testing, and pipe movement should not be done until after the joints have been given sufficient time to dry.
47 2. Design safeguards into the system to prevent excessive surge pressures. Water haer (surge) in a PVC and CPVC system can cause pipe, fittings, and valves to burst. Liquid velocities should not exceed five feet per second maximum. Installation 1. Carefully follow solvent cement welding instructions. Failure to correctly follow application procedures can reduce the strength and integrity of joints and cause joint failures. By far, the majority of failures in PVC and CPVC systems are the result of shortcuts and/or improper joining techniques. 2. Remove rocks and other debris that can rupture pipe when burying pipe in trenches. When laying PVC and CPVC pipe below the ground, care should be taken to remove all rocks, boards, empty primer and cement cans, brushes, bottles and other debris from the trench. Backfilling and top loading should be watched very carefully. 3. Follow recoended support spacing for PVC and CPVC piping systems. The modulus of elasticity of PVC and CPVC pipe is smaller than metals. Maximum working temperature and room temperature should be considered when determining the required support spacing. ONLY hydrostatic pressure testing is to be conducted on PVC and CPVC piping systems. Compressed air or gases can surge to high pressures and cause explosive failures that could seriously injure personnel. 2. Carefully follow all instructions for hydrostatic pressure testing. Failure to follow these instructions can result in a system failure. 3. Before water-testing a system, always bleed all entrapped air from system. Entrapped air is a major cause of surge and burst failure in plastic piping systems. 46 Safety Precautions Testing 1. NEVER use compressed air or gas or air-overwater boosters to pressure test PVC or CPVC piping systems. ESLON SCH80 PVC & CPVC Piping Sysyems
48 SEKISUI CHEMICAL CO.,LTD. Industrial Piping System Division Toranomon Minatoku,Tokyo, Japan TEL FAX SEKISUI INDUSTRIAL PIPING CO., LTD. No.18, Jing 1st Rd.,Chung Kang Export Processing Zone, Wuqi Dist., Taichung City 43541, Taiwan, R.O.C. TEL FAX SEKISUI (SHANGHAI) INTERNATIONAL TRADING CO., LTD. Room , Metro Tower, No.30, Tianyaoqiao Road Shanghai , China TEL FAX SEKISUI CHEMICAL SINGAPORE (PTE.) LTD. 2 Jurong East Street Road 21,#05-17,IMM Building,Singapore TEL FAX SEKISUI CHEMICAL G.m.b.H. Cantadorstr Dusseldorf, Germany TEL FAX SEKISUI VIETNAM CO.,LTD Room1414, CornerStone Building, 16Phan Chu Trinh St, Hoan Kiem District, Hanoi, Vietnam TEL FAX Copyright 2008 SEKISUI CHEMICAL CO., LTD. May not be copied in whole or part. Revision No.1, Jan Printed November rd Edition ESLON SCH80 PVC & CPVC Piping Systems Specifications & Engineering Manual SEKISUI CHEMICAL CO.,LTD. Industrial Piping System Division No TH TX
Solvent Cementing Instructions For Plastic Pipe & Fittings
Solvent Cementing Instructions For Plastic Pipe & Fittings Description Solvent cementing is the process of fusing plastic pipe and fittings by the use of an adhesive containing a suitable active solvent
For drinking water pipe distribution systems, both main and supply lines Sewer and discharge pipe systems
Technical Information UPVC upvc (unplasticized polyvinylchloride) pipes and fittings exhibit excellent resistance to aggressive environments both naturally occurring and as a result of industrial activity.
Green Thread Product Data
Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using
Engineering Specifications
PUREFLOW PEX PRODUCTS PART 1 GENERAL 1.1 SUMMARY 1.1.1 This specification covers Branch & Main, Parallel Water Distribution Systems (MANABLOC), Cross-linked Polyethylene tubing and fittings using PEX Press
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
HYDROSTATIC PRESSURE TESTING
HYDROSTATIC PRESSURE TESTING Plastic pipe is not designed to provide structural strength beyond sustaining internal pressures up to its designed hydrostatic pressure rating and normal soil loads. Anchors,
DOUBLE CONTAINMENT DESIGN & INSTALLATION GUIDE
DC-3-0708 Spears Double Systems are engineered for ease of installation and lower associated installation costs. Complete systems include all necessary components - carrier pipe, containment pipe, centralizer
pvc well casing & drop pipe
CertainTeed pvc well casing & drop pipe PVC Well Products Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due to its outstanding
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION PART 1 GENERAL.01 SECTION INCLUDES Furnishing and installing 4 inch through 16 inch high density
INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles
INSTALLATION RECOMMENDATIONS Outdoor Rubber Tiles Prior to Installation: The Outdoor Rubber Tiles and accessory transition pieces intended for this installation have been shipped to you via a freight carrier
AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids
AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids The AMERICAN Mechanical Joint was developed by the American Cast Iron Pipe Company and first marketed in 1929. Since that time, millions
Series 4000 Fiberglass Pipe and Fittings
Series 4000 Fiberglass Pipe and Fittings for corrosive industrial service Uses and applications Listings Performance Acid drains Chemical process piping Corrosive slurries Food processing Geothermal Nonoxidizing
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
Rental Services Temporary Cooling - Flexible Water Hose
Engineering Bulletin Rental Services Temporary Cooling - Flexible Water Hose September 2006 CHS-PRB007-EN Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate
PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.
CONDENSED CATALOG PVC HPB-0-A Effective 9//97 Revised //99 CLEAR / / / / -/ -/ -/ x/ CLEAR / / / / -/ PVC SDR. PSI (Water @ 7. F.) /.0.9.0.0 PVC SDR -/ -/ -/ 0 0 PVC SCHEDULE 0.0.7.0.00..7.7.00.000.00...
Plastics TECHNICAL AND INSTALLATION MANUAL. (Updated June 10, 2016) TECHNICAL MANUAL TM-PL. 2001-2016 Charlotte Pipe and Foundry Co.
Plastics TECHNICAL AND INSTALLATION MANUAL ABS DWV ABS Plus Foam Core PVC DWV RePVC DWV Pipe with Recycled Content PVC Sewer & Pressure Pipe PVC Schedule 40 & 80 FlowGuard Gold CTS CPVC ReUze CTS CPVC
Schedule 40 & Schedule 80 Rigid PVC Piping Systems Scroll Down for Dimensions, Components, Hangars & Supports, Fabrication Techniques
Schedule 40 & Schedule 80 Rigid PVC Piping Systems Scroll Down for Dimensions, Components, Hangars & Supports, Fabrication Techniques Schedule 40 Rigid PVC Piping Systems SCHEDULE 40 - DIMENSIONS Harvel
SECTION 33 11 00.13 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS
SECTION 33 11 00.13 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS PART 1: GENERAL 1.01 SECTION INCLUDES Furnishing and installing up to 16-inch high density polyethylene (HDPE) pipe and fittings for
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
Application Data Important Safety Information
Application Data Important Safety Information Read this page before using any of the information in this catalog. This catalog is designed to be used as a guide in selecting the proper hose for the applications
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
GATE VALVES ASAHI AV VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1
Serial No. H-V011-E-11 GATE VALVES Type P (Standard: Plug) Type S (Soft Seal) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
01 - Plastic Pipe Cements and Primers
01 - Plastic Pipe Cements and Primers Q - What is the shelf life of the cement and primers? PVC & ABS Cements / Primers and Cleaners have 3 year shelf life from date of manufacture, and CPVC has 2 year
CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.
CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
Mold Preventing I nterior System
interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests
Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages
Royal Seal Gasketed Sewer Pipe
Royal Seal Gasketed Sewer Pipe Royal Seal Gasketed Sewer Pipe Royal Seal gasketed sewer pipe with our specially designed Double Seal Locked-In (DSLI ) gasket is an extremely durable pipe with a leak proof
AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller
January 2013 AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller Milliken Valve Company 190 Brodhead Avenue, Suite 100 Bethlehem, PA 18017 Phone: (610) 861-8803 Fax:
RAUFOSS EXPLOSIVE COMPRESSION FITTINGS
INSTRUCTION MANUAL FOR RAUFOSS EXPLOSIVE COMPRESSION FITTINGS Box 7 2831 Raufoss Norway Tlf.: +47 61 15 17 87 Fax: +47 61 15 25 56 25 January 2013, rev 2 Available on www.vpmetall.no Page 1 CONTENTS GENERAL
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved
Compressed Gas Cylinder Safety
Compressed Gas Cylinder Safety I. Background. Due to the nature of gas cylinders, special storage and handling precautions are necessary. The hazards associated with compressed gases include oxygen displacement,
Product Knowledge Guide. (Updated May 2015) BR-PK 2004-2015 Charlotte Pipe and Foundry Company.
Product Knowledge Guide (Updated May 2015) BR-PK 2004-2015 Charlotte Pipe and Foundry Company. You can t beat the system. Charlotte Pipe s Retail Division Charlotte Pipe and Foundry Company is the largest
Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL
155 E. Front Street (rear) Lititz, PA 17543 Phone (717) 625-1930 Fax (717) 625-1931 Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL CONSTRUCTION SPECIFICATIONS AND DETAILS
Socket Heat Fusion Techniques. A Guide for Instruction and Training in Vanguard Socket Heat Fusion
Socket Heat Fusion Techniques A Guide for Instruction and Training in Vanguard Socket Heat Fusion TABLE OF CONTENTS This brochure has been developed to assist those responsible for socket fusion joining
CATHODIC PROTECTION SYSTEM DESIGN
CATHODIC PROTECTION SYSTEM DESIGN Presented By DENIS L ROSSI P.E. CORROSION ENGINEER New England C P Inc. Corrosion Fundamentals What is corrosion? It is defined as the degradation or deterioration of
GigaCrete Specification PlasterMax
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
SECTION 15105 DUCTILE IRON PIPE AND FITTINGS
SECTION 15105 DUCTILE IRON PIPE AND FITTINGS PART 1 GENERAL.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of Owner facilities. Closely coordinate construction work and connections
The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
Section 33 0200- Page 1 of 4 PART 1 - GENERAL 1.1 DESCRIPTION OF WORK The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE
6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
Tubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness
www.swagelok.com Tubing Data Contents Tubing Selection... 1 Tubing Handling.... 1 Gas Service... 2 Tubing Installation.... 2 Suggested Allowable Working Pressure Tables Carbon Steel Tubing... 3 Stainless
OWNER S MANUAL Table Tennis Table Patent Pending
OWNER S MANUAL Table Tennis Table Patent Pending Be sure to write your model number and serial number here for future reference. You can find these numbers printed on the bottom of the table. MODEL # T8179
Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems
Pipe and Equipment Insulations Zeston PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems Zeston PVC Insulated Fitting Covers Installation Instructions for Hot,
Section 6 Brake Drum Failure Analysis. Brake Drum Wear Conditions. What is Normal Wear? What is Deep or Excessive Wear? WARNING. Deep, Uniform Wear
Section Brake Drum 6 Failure Analysis WARNING To prevent serious eye injury, always wear safe eye protection when you perform vehicle maintenance or service. Figure 6.1 ASBESTOS AND NON-ASBESTOS FIBERS
SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS
SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work
Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, 2016. Product Description
3 Scotch-Weld TM 1838 1838 1838-L Technical Data February, 2016 Description 3M TM Scotch-Weld TM s 1838 and are controlled flow products; Scotch-Weld 1838-L is flowable. These epoxy adhesives are two-part,
Product Guide Specification
Stabilit America, Inc., dba Glasteel June 2005 285 Industrial Drive Moscow, Tennessee 38057 Toll Free (800) 238-5546 Phone (901) 877-3010 Fax (901) 877-1388 Web Site www.glasteel.com Product Guide Specification
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
Chapter 2 Basis of design and materials
Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural
Caps STANDARD WEIGHT Inches / Pounds
Standard Caps you are here: Home > Weldbend Catalog > Fittings > Caps Caps STANDARD WEIGHT Inches / Pounds For Metric Units >Click Here Nominal Pipe Size Outside Inside Wall Thickness (T) Length (E) Pipe
COATING & WRAPPING OF UNDERGROUND PIPING
CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES 1 PART 1 - GENERAL 1.0 GENERAL 1.1 REFERENCES: SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS
Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls
Pre- insulated pipe systems ecoflex Wall Penetration installation guide Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre-insulated Pipe Systems
PNEUMATIC - HIGH PRESSURE FLAT-FORM HEAVY LIFTING BAGS
PLEASE READ AND UNDERSTAND THIS MANUAL BEFORE USING SAVA LIFTING BAGS PNEUMATIC - HIGH PRESSURE FLAT-FORM HEAVY LIFTING BAGS & INFLATION ACCESSORIES SAFETY, OPERATION AND MAINTENANCE INSTRUCTIONS NON-COMPLIANCE
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL
PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL Boiler Manual A. INSTALLING EXHAUST VENT AND INTAKE AIR VENT B. GENERAL n DANGER The Elite Heating Boiler must be vented as detailed in this section.
Native InDesign 2890 SaniTite Brochure 1/8" 100 300 CMYK April 17, 07
Sanitary Sewer Pipe Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness
1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.
CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Special Conditions and Division 1 Specifications
TYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
MASONRY RESTORATION Lime Putty Mortar Repointing Guide
1.0 Preparation for Lime Putty Mortar Pointing 1.1 Tools & Approach A. Grinding - When used in a controlled way, angle grinders with diamond-impregnated metal blades with a maximum 1/8-inch-thickness and
DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT
3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT Instruction D10386 August 2013 Instructions These instructions provide installation, operation and maintenance information for BAW Butterfly Valves.
RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants
RTV159 RTV157 and RTV159 High Strength Silicone Adhesive Sealants Product Description RTV157 and RTV159 are one-component, ready-to-use, high strength silicone rubber adhesive sealants. They cure to tough
San josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof.
BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof. 1155 & 4155 LCL: Applies to all freight in less than container load quantities.
SPECIFIC INSTRUCTIONS ON HOW TO PERIODICALLY CHECK FOR STRESS CRACKING CAUSED BY CHEMICALS, HANDLING ABUSE & ENVIRONMENTAL DEGRADATION
SPECIFIC INSTRUCTIONS ON HOW TO PERIODICALLY CHECK FOR STRESS CRACKING CAUSED BY CHEMICALS, HANDLING ABUSE & ENVIRONMENTAL DEGRADATION Provides the same capability for checking your liquid bulk storage
BLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
Lenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503
1 User s Guide to: Phoenix Vessel Technology Limited 1000 psi End port pressure vessels 2.5. Model number: 1503 Lenntech [email protected] Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Phoenix
Installation Guide. Recommendations for Installation of IPS & PIP Pressure Pipe
Installation Guide Recommendations for Installation of IPS & PIP Pressure Pipe INDEX Index......... 1 Diamond Plastic Pipe....... 2 PVC Installation Guide...... 2 Handling & Storage....... 2 Receiving
University of Tennessee Safety Guidelines
University of Tennessee Safety Guidelines Guideline Subject: Compressed Gases and Cryogenics Safety Guidelines Approval Date: 10/1/15 (Rev. 1) Next Scheduled Review: 10/1/19 Date Effective: 1/01/09 Contact
Pipe Protection Tape System
Pipe Protection Tape System PASCO All Weather Pipe Protection Tape is a pure physical barrier that is moisture proof, inert and non-conducting. Whether the need is to protect overhead piping in industrial
VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised
Page 1 of 6 instructions VC 104+ Rigid Grade / VC 104+ Rigid Grade Imagine / (for the rest of this document referred to as VC 104) can be applied to new and used trucks and trailers with painted rigid
Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
GeoTEXTILE Products INSTALLATION QUALITY ASSURANCE manual
GeoTEXTILE Products INSTALLATION QUALITY ASSURANCE manual Contents 1.0 INTRODUCTION...1 2.0 MATERIAL...1 3.0 MATERIAL DELIVERY...1 4.0 SITE UNLOADING PROCEDURES...1 5.0 SITE HANDLING & STORAGE PROCEDURES...1
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.
ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.4-1998 - Cast Iron Threaded Fittings ASME/ANSI B16.5-1996 - Pipe
MaxCell Technical Manual Design Parameters
MaxCell Technical Manual Design Parameters Breaking Strength by Product Style, lbs Product Style Standard MaxCell Fire Resistant MaxCell Test Method 4 Cell 2,750 2,200 ASTM D 5 Bellcore 5 5.. Cell 2,50
Copper and Copper Alloy Tube, Pipe and Fittings
Copper and Copper Alloy Tube, Pipe and Fittings COPPER and COPPER ALLOY TUBE and PIPE Seamless Copper Pipe: Copper pipe is almost pure copper manufactured to the requirements of ASTM B 42 - Standard Specification
One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty
One Year Warranty ELECTRIC Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches Fused Ceramic Shield tank lining is corrosion-resistant for years of dependability. Adjustable
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
BRAKE DRUM AND ROTOR SERVICE INFORMATION
SERVICE INFORMATION To achieve maximum drum life and optimum performance, proper brake maintenance and brake balance are essential. Consult your truck or trailer manufacturer s maintenance manual for proper
Technical Note 802 Leak Testing of Polyethylene Pipe For Municipal and Industrial Applications Part 1 Pre-Test Considerations
Technical Note 802 Leak Testing of Polyethylene Pipe For Municipal and Industrial Applications Part 1 Pre-Test Considerations Leak testing may be used to find leaks in a newly constructed or newly modified
ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600
OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done
Most suitable piping material
Oct. 13 1st Edition NEW NEW Rigid PVC Pipe and Fittings with anti water condensation layer for air conditioning drainage ESON AC DRAIN PIPE ESON AC DRAIN Fittings ESON AC DRAIN Fittings ESON AC DRAIN Flexible
MODEL J SERIES CONVERTER
3030 S Susan Street, MODEL J SERIES CONVERTER REPAIR KIT INSTRUCTIONS Important: Any maintenance, service or repair should be performed by trained and experienced service technicians. Proper tools and
SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND.
SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. 623.10.1 Description. This work shall consist of preparing the surface,
GENERAL PROPERTIES //////////////////////////////////////////////////////
ALLOY 625 DATA SHEET //// Alloy 625 (UNS designation N06625) is a nickel-chromium-molybdenum alloy possessing excellent resistance to oxidation and corrosion over a broad range of corrosive conditions,
STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS
STANDARD SPECIFICATIONS SECTION 02512 CLEANING AND LINING WATER MAINS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for cleaning and lining existing cast iron and ductile iron water mains
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
During Various Aluminum Fabricating Operations
Guidelines for Handling Aluminum Fines Generated During Various Aluminum Fabricating Operations F-1 Guidelines for Handling Aluminum Fines Generated During Various Aluminum Fabricating Operations SCOPE
RTV162. Electronic Grade Silicone Adhesive Sealant
RTV162 Product Description Electronic Grade Silicone Adhesive Sealant RTV162 adhesive sealant from GE Silicones is one-component, readyto-use electronic grade silicone sealant. It cures to a tough, resilient
NAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE
NAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE GENERAL a. These specifications may be used in whole or in part by any party without